testo 557 Digital manifold Instruction manual
|
|
|
- Jessie Cannon
- 9 years ago
- Views:
Transcription
1 testo 557 Digital manifold Instruction manual
2 2
3 1 Contents 1 Contents 1 Contents Safety and the environment About this document Ensure safety Protecting the environment Specifications Use Technical data Bluetooth Modul General technical data Product description Overview First steps Using the product Preparing for measurement Switching the instrument on Connecting the temperature sensor Connecting the vacuum probe Switching Bluetooth on and off Choosing the measuring mode Performing the measurement Maintaining the product Tips and assistance Questions and answers Measurement parameters Error reports Accessories and spare parts EC Declaration of Conformity
4 2 Safety and the environment 2 Safety and the environment 2.1. About this document Use > Please read this documentation through carefully and familiarize yourself with the product before putting it to use. Pay particular attention to the safety instructions and warning advice in order to prevent injuries and damage to the products. > Keep this document to hand so that you can refer to it when necessary. > Hand this documentation on to any subsequent users of the product. Symbols and writing standards Representation Explanation Warning advice, risk level according to the signal word: Warning! Serious physical injury may occur. Caution! Slight physical injury or damage to the equipment may occur. > Implement the specified precautionary measures. Note: Basic or further information Action: more steps, the sequence must be followed. >... Action: a step or an optional step Result of an action. Menu Elements of the instrument, the instrument display or the program interface. [OK] Control keys of the instrument or buttons of the program interface Functions/paths within a menu.... Example entries 4
5 2 Safety and the environment 2.2. Ensure safety > Do not operate the instrument if there are signs of damage at the housing, mains unit or feed lines. > Do not perform contact measurements on non-insulated, live parts. > Do not store the product together with solvents. Do not use any desiccants. > Carry out only the maintenance and repair work on this instrument that is described in the documentation. Follow the prescribed steps exactly. Use only original spare parts from Testo. > Dangers may also arise from the systems being measured or the measuring environment: Note the safety regulations valid in your area when performing the measurements. > If the measuring instrument falls or another comparable mechanical load occurs, the pipe sections of the refrigerant hoses may break. The valve positioners may also be damaged, whereby further damage to the interior of the measuring instrument may occur that cannot be identified from the outside. The refrigerant hoses must therefore be replaced with new, undamaged refrigerant hoses every time the measuring instrument falls or following any other comparable mechanical load. Send the measuring instrument to Testo Customer Service for a technical check for your own safety. > Electrostatic charging can destroy the device. Integrate all the components (system, manifold's valve block, refrigerant bottle etc.) into the potential equalisation (earthing). Please see the safety instructions for the system and the refrigerant used Protecting the environment > Dispose of faulty rechargeable batteries/spent batteries in accordance with the valid legal specifications. > At the end of its useful life, send the product to the separate collection for electric and electronic devices (observe local regulations) or return the product to Testo for disposal. > Refrigerant gases can harm the environment. Please note the applicable environmental regulations. 5
6 3 Specifications 3 Specifications 3.1. Use The testo 557 is a digital manifold for maintenance and service work on refrigeration systems and heat pumps. The device is only to be used by qualified expert personnel. With its functions the testo 557 replaces mechanical manifolds, thermometers and pressure/temperature charts. Pressures and temperatures can be applied, adapted, tested and monitored. The testo 557 is compatible with most of the non-corrosive refrigerants, water and glycol. The testo 557 is not compatible with ammoniac refrigerants. Then product must not be used in explosive environments! 3.2. Technical data Bluetooth Modul Feature Bluetooth The Bluetooth option may only be operated in countries in which it is type approved. Bluetooth type Values Qualified Design ID B Bluetooth radio Class 3 class Bluetooth company Range >20 m (free field) LSD Science & Technology Co., Ltd L Series BLE Module (08 Mai 2013) based on TI CC254X chip Certification Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, United Kingdom. EFTA countries Island, Suisse, Norway, Lichtenstein. 6
7 3 Specifications Other countries USA, Turkey, Hong Kong, Canada. Information from the FCC (Federal Communications Commission) This device complies with part 15 of the FCC Rules. Commissioning is subject to the two following conditions: (1) This instrument must not cause any harmful interference and (2) this instrument must be able to cope with interference, even if this has undesirable effects on operation. Changes The FCC demands that the user be informed that any changes or modifications to the instrument that are not explicitly approved by Testo AG may void the user's right to use this instrument General technical data Feature Values Measurement Pressure: psi/ kpa/mpa/bar parameters Temperature: F/ C/K Vacuum: micron / inhg / inh 2O / hpa / mbar/ mtorr /Torr / Pa Sensing element Pressure: 2 x pressure sensors Temperature: 2 x NTC Vacuum: via external probe Measuring cycle 0,5s Interfaces Pressure connections: 3 x 7/16" UNF, 1x 5/8" UNF NTC measurement External vacuum probe Measurement ranges Overload Pressure measurement range HP/LP: psi / kpa / MPa / bar (rel) Temperature measurement range: F / C Measurement range vacuum: Mikron 940 psi, 65 bar, 6500 kpa, 6.5 MPa 7
8 3 Specifications Feature Values Resolution Resolution pressure: 0.1 psi / 0.01 bar / 1 kpa / MPa Resolution temperature: 0.1 F / 0.1 C / 0.1 K Vacuum resolution: 1 Mikron (from 0 to 1000 Mikron) 10 Mikron (from 1000 to 2000 Mikron) 100 Mikron (from 2000 to 5000 Mikron) 500 Mikron (from 5000 to Mikron) 5000 Mikron (from to Mikron) Accuracy (nominal temperature 71.6 F / 22 C) No. of refrigerants 60 Selectable refrigerants Measurable media Ambient conditions Pressure: ±0.5% of final value (±1 digit) Temperature ( F/ C): ±0.9 F (±1 digit), ±0.5 C (±1 digit) Vacuum: ±(10 Mikron + 10% v. Mw.) ( Mikron) No refrigerant, R11, R12, R22, R123, R1234ze, R125, R13B1, R134a, R14, R142B, R152a, R161, R23, R227, R290, R32, R401A, R401B, R401C, R402A, R402B, R404A, R406A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R410A, R411A, R412A, R413A, R414B, R416A, R417A, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R426A, R427A, R434A, R437A, R438A, R502, R503, R507, R508A, R508B, R600, R600a, R718 (H2O), R744 (CO2) (only in permissible measurement range up to 60 bar), R1234yf Measurable media: all media that is stored in the testo 557. Not measurable: ammonia (R717) and other refrigerants which contain ammonia Operating temperature: F / C C / F (Vacuum) Storage temperature: F / C Humidity in area of use: 10 90%rF 8
9 3 Specifications Feature Housing IP-class 42 Values Material: ABS / PA / TPE Dimensions approx. 280 x 135 x 75 mm Weight: approx g (without batteries) Power supply Current source: Rechargeable batteries / batteries 4 x 1.5V type AA / Mignon / LR6 Battery lifetime: approx. 250 h (Bluetooth off, vacuum probe not connected) Display Type: Illuminated LCD Response time: 0.5 s Directives, EC Directive: 2014/30/EC standards and tests Warranty Duration: 2 years Terms of warranty: see website 9
10 4 Product description 4 Product description 4.1. Overview Display and control elements 1 Front connection for external vacuum probe 2 Sensor socket Mini-DIN for NTC-temperature sensor, with socket cover 3 Suspension attachment, foldable (backside). 4 Display. Instrument status icons: Icon Meaning Battery capacity Bluetooth, see Switching Bluetooth on and off, page 16 / / Select measuring mode, see Choosing the measuring mode, page 17 5 Battery compartment. The rechargeable batteries cannot be charged inside the instrument! 10
11 5 First steps 6 Control keys: Key [Set] [R,, ] [Mode] [Min/Max/Mean] [ ] [P=0] Esc [ ] Function Set units Select refrigerant / Start-Stop leak test Switch between measuring modes Show min, max, mean values Up-key: Change display view. Pressure zeroing Switches to the measurement/home view. Down-key: changes display view. [ / ] Switch the instrument on/off, Light key: switches display light on/off. 7 Inspection glass for refrigerant flow. 8 4 x valve actuators 9 4 x hose brackets for refrigerant hoses 10 Connection 7/16" UNF, brass. High pressure, for refrigerant hoses with quick release screw fitting, passage for valve actuator lockable. 11 Connection 5/8" UNF, brass, for vacuum pump 12 Connection 7/16" UNF, brass, for e.g. refrigerant cylinders, with screw cap. 13 Connection 7/16" UNF, brass. Low pressure for refrigerant hoses with quick release screw fitting, passage for valve actuator lockable. 14 On the back below the battery compartment cover, mini-usb connection for firmware update. 5 First steps Inserting batteries/rechargeable batteries 1. Unfold the suspension attachment and open the battery compartment (clip lock). 2. Insert the batteries (scope of delivery) or rechargeable batteries (4 x 1.5 V, type AA / Mignon / LR6) into the battery compartment. Observe the polarity! 3. Close the battery compartment. - After insertion of the batteries, the instrument switches on automatically and goes into the settings menu. 11
12 5 First steps When not in use for long period: Take out the batteries / rechargeable batteries. Performing settings 1. Press [Set] repeatedly, 2. Press [ ] or [ ] to select the unit/parameter. The settings will be accepted once the last selection has been made. Key functions Representation [ ] or [ ] [Set] Adjustable parameters Representation C, F Explanation Change parameter, select unit Select units/parameters Explanation Set unit for temperature. bar, kpa, MPa, psi Set unit for pressure. Pabs, Prel or psig Depending on the chosen unit for pressure: Change between absolute and relative pressure displays. micron, inhg, Pa, Set pressure unit for vacuum. hpa, mtorr,torr, inh2o, mbar / / Select the measuring mode AUTO OFF T fac Automatic switch-off time, instrument switches off after 30 minutes if no temperature probe is connected and there is no pressure apart from ambient pressure. Temperature compensation factor, icon is shown on the display if the function is disabled. Operating the valve actuators With respect to the refrigerant flow path the digital manifold behaves just like a conventional four-way manifold. The passages are opened by opening the valves. The applied pressure is measured with the valves closed and the valves opened. 12
13 5 First steps > Open the valve: Turn valve actuator anticlockwise. > Close the valve: Turn valve actuator clockwise. WARNING Valve positioner tightened too tightly. Damage to the PTFE seal (1). Mechanical deformation of the valve piston (2) leading to the PTFE seal (1) falling out. Damage to the thread of the threaded spindle (3) and the valve screw (4). Broken valve knob (5). Tighten the valve positioner only hand-tight. Do not use any tools to tighten the valve positioner. 13
14 6 Using the product 6 Using the product 6.1. Preparing for measurement Switching the instrument on > Press [ ]. Zeroing the pressure sensors Zero the pressure sensors before every measurement. All connections must be pressureless (ambient pressure). > Press for 2 seconds key [P=0] and execute zeroing Connecting the temperature sensor Surface temperature sensor An NTC temperature sensor (accessory) must be connected for measuring the pipe temperature and for automatic calculation of superheating and subcooling. Deactivating the surface compensation factor for insertion and air temperature sensor A surface compensation factor has been set in the measuring instrument to reduce the measuring errors in the main field of applications. This reduces measuring errors when using surface temperature sensors. 1. Press [Set] repeatedly until T fac is displayed. 2. Press [ ] or [ ] to set T fac to Off. 3. Press [Set] to continue through the settings menu until the measurement/home view is displayed. - T fac is shown on the display if T fac is disabled. 14
15 6 Using the product Connecting the refrigerant hoses Before each measurement check whether the refrigerant hoses are in flawless condition. The valve actuators are closed. 1. Connect the refrigerant hoses for low-pressure side (blue) and high-pressure side (red) to the measuring instrument. 2. Connect the refrigerant hoses to the system. WARNING The measuring instrument dropping down or any other comparable mechanical load can cause breakage of the pipe pieces in the refrigerant hoses. The valve actuators may also suffer damage, which in turn could result in further damage inside the measuring instrument, which may not be detectable from outside. > For your own safety you should return the measuring instrument to the Testo Service for technical inspection. > You should therefore always replace the refrigerant hoses with new ones after the measuring instrument has dropped down or after any comparable mechanical loading. Setting the refrigerant 1. Press [R,, ]. - This opens the refrigerant menu and the currently selected refrigerant flashes. 2. Setting the refrigerant: Key functions Representation [ ] or [ ] [R,, ] Explanation Changing the refrigerant Confirm the setting and exit the refrigerant menu. 15
16 6 Using the product Available refrigerants Representation Explanation R... Refrigerant number of refrigerant acc. to ISO no refrigerant selected. Example: Setting refrigerant R401B 1. Press [ ] or [ ] several times, until R401B flashes. 2. Press [R,, ] to confirm the setting. Quitting the refrigerant selection > Press [R,, ] or automatically after 30 s, if no other key has been pressed Connecting the vacuum probe > Open the front cover of the connector and connect up the vacuum probe. - The instrument automatically switches to the vacuum measurement mode Switching Bluetooth on and off In order to be able to establish a connection via Bluetooth, you need a tablet or smartphone with the Testo app Refrigeration already installed on it. You can get the App for ios instruments in the App Store or for Android instruments in the Play Store. Information about compatibility can be found in the relevant app store. 1. Press [ ] and [ ] simultaneously and hold down for 3 seconds. - Once the Bluetooth icon is shown on the display, Bluetooth is switched on. Display Explanation flashes There is no Bluetooth connection, or a potential connection is being searched for. is permanently displayed is not displayed There is a Bluetooth connection. Bluetooth is disabled. 16
17 6 Using the product 2. Press [ ] and [ ] simultaneously and hold down for 3 seconds. - Once the Bluetooth icon is no longer shown on the display, Bluetooth is switched off Choosing the measuring mode 1. Press [Set] several times 2. Press [ ] or [ ] to select the function. 3. Saving settings: Press [Set]. - The measuring mode is displayed. Display Mode Function Refrigeration system Heat pump Automatic mode Normal function of the digital manifold Normal function of the digital manifold When automatic mode is activated the digital manifold testo 557 automatically reverse the display of high and low pressure. This automatic reversal occurs when the pressure in the low pressure side is 1 bar higher than the pressure in the high pressure side. This switching over is indicated by ---- flashing in the display. This mode is particularly suitable for air conditioning systems that provide cooling and heating. 17
18 6 Using the product 6.2. Performing the measurement WARNING Risk of injury caused by pressurized, hot, cold or toxic refrigerants! > Wear protective goggles and safety gloves. > Before applying pressure to the measuring instrument: Always fasten the measuring instrument on the suspension attachment to prevent it from falling down (danger of breakage) > Before each measurement check the refrigerant hoses for flawless condition and correct connection. Do not use any tools to connect the hoses, tighten hoses only hand-tight (max. torque 5.0 Nm / 3.7 ft*lb). > Comply with the permissible measuring range ( psi / bar). Pay particular attention in systems with refrigerant R744, since these are frequently operated with higher pressures. Measuring The actions described in the chapter Preparing for measurement have been performed. 1. Apply pressure to the measuring instrument. 2. Read the measuring values. With zeotropic refrigerants, the evaporation temperature to/ev is displayed after the complete evaporation / the condensation temperature tc/co is displayed after complete condensation. The measured temperature must be assigned to the superheating or subcooling side (t oh <--> t cu). Dependent on this assignment, the display will show t oh/t1 resp. Δt oh/sh or t cu/t2 resp. Δt cu/sc, depending on the selected display. - Reading and display illumination are flashing. 14,5 psi/1 bar before the critical pressure of the refrigerant is reached, when the max. permissible pressure of 870 psi/60 bar is exceeded. 18
19 6 Using the product Key functions > [ ] or [ ]: Change the readings display. Possible display combinations: Evaporation pressure Refrigerant evaporation temperature to/ev or (only with inserted temperature sensor) Evaporation pressure Measured temperature t oh/t1 or (only with inserted temperature sensor) Evaporation pressure Superheating Δt oh/sh Condensation pressure Refrigerant condensation temperature tc/co Condensation pressure Measured temperature t cu/t2 Condensation pressure Subcooling Δt cu/sc With two inserted NTC sensors Δt is additionally displayed. > [Mean/Min/Max]: Hold readings, min. / max. readings, show mean values (since switching on). Leak test / pressure drop test The temperature compensated leak test can be used to check the leak tightness of systems. For this purpose both the system pressure and the ambient temperature are measured over a defined period of time. For this purpose a temperature sensor to measure the ambient temperature may be connected (recommendation: Deactivate the surface compensation factor (see page 14) and use NTC air sensors Art.-No ). This provides information about the temperature compensated differential pressure and about the temperature at the beginning/end of the test as a result. If no temperature sensor is connected, you may also perform the leak test without temperature compensation. The actions described in the chapter Preparing for measurement have been performed. 1. Press [Mode] - The leak test view is opened. ΔP is displayed. 2. Start the leak test: Press [R,, ]. 3. End the leak test: Press [R,, ]. - The result is displayed. 4. Confirm the message: Press [Mode]. - Main menu display. 19
20 6 Using the product Evacuation / vacuum display > Connect vacuum probe. Vacuum measurement The vacuum probe is plugged into the front connection of the manifold and connected to the system. 1. Press [Mode]. - The vacuum measurement menu appears. If ambient pressure is applied to the vacuum probe, then oooo is shown on the display. 2. Start the vacuum pump. - Once the measuring range 0 to 20,000 microns is reached, the current vacuum value is shown on the instrument display. The instrument also displays the current ambient temperature, the water evaporation temperature, which corresponds to the vacuum reading, and the delta between these two temperatures. 3. To leave vacuum mode, remove the vacuum probe from the testo 557 or switch to the standard measurement view using the mode button. 20
21 7 Maintaining the product 7 Maintaining the product Cleaning the instrument Do not use any aggressive cleaning agents or solvents! Mild household cleaning agents and soap suds may be used. > If the housing of the instrument is dirty, clean it with a damp cloth. Keeping connections clean > Keep screw connections clean and free of grease and other deposits, clean with a moist cloth as required. Removing oil residues > Carefully blow out oil residues in valve block using compressed air. Ensuring the measuring accuracy Testo Customer Service would be glad to further assist you if you so wish. > Check instrument regularly for leaks (recommended: annually). Keep to the permissible pressure range! > Calibrate instrument regularly (recommended: annually). Changing batteries/rechargeable batteries Instrument is switched off. 1. Fold out the suspension device, loosen the clip and remove the cover of the battery compartment. 2. Remove empty batteries/rechargeable batteries and insert new batteries/rechargeable batteries (4x 1.5 V, type AA, Mignon, LR6) in the battery compartment. Observe the polarity! 21
22 7 Maintaining the product 3. Set on and close cover of the battery compartment (clip must engage). 4. Switch the instrument on. Cleaning the vacuum probe Contaminants such as oil may impair the accuracy of the vacuum sensor. CAUTION Carrying out cleaning with the probe connected may result in damage to the probe! > Remove the vacuum probe from the testo 557! CAUTION Damage to the sensor due to sharp objects! > Do not insert any sharp objects into the probe! 1. Remove the vacuum probe from the testo Put a few drops of rubbing alcohol into the sensor opening. 3. Seal the opening by placing your finger on it and shake the vacuum probe briefly. 4. Remove all the alcohol from the probe. 5. Repeat this process at least twice. 6. Leave the probe to dry for at least 1 hour. To dry the sensor faster, you can connect the probe directly to a vacuum pump and draw vacuum. 22
23 8 Tips and assistance 8 Tips and assistance 8.1. Questions and answers Question flashes The instrument switches off automatically. uuuu lights up instead of the parameter display oooo lights up instead of the parameter display 8.2. Measurement parameters Name bar, C Psi, F Possible causes/solution Batteries are almost empty. > Change batteries. Residual capacity of the batteries is too low. > Change batteries. The permissible measuring range has been undershot. > Keep to the permitted measuring range. The permissible measuring range has been exceeded. > Keep to the permitted measuring range. Description Δtoh SH Superheating, evaporation pressure Δtcu SC Subcooling, condensation pressure to Ev Refrigerant evaporation temperature tc Co Refrigerant condensation temperature toh T1 Measured temperature, evaporation tcu T2 Measured temperature, condensation 23
24 8 Tips and assistance 8.3. Error reports Question ---- is lit up instead of measurement parameter display Display EEP FAIL Display BT ERR Display ERR 2-5 Possible causes/solution Sensor or cable defective > Please contact your dealer or Testo Customer Service Eeprom defective > Please contact your dealer or Testo Customer Service No BT module connected or BT module defective. > Please contact your dealer or Testo Customer Service Damaged vacuum sensor > Please contact your dealer or Testo Customer Service If you have any questions, please contact your dealer or Testo Customer Service. The contact details can be found on the back of this document or on the Internet at Accessories and spare parts Description Article no. Clamp probe for temperature measurement at pipes (1,5m) Clamp probe for temperature measurement at pipes (5m) Pipe wrap probe with Velcro tape for pipe diameters of up to max. 75 mm, Tmax. +75 C, NTC Watertight NTC surface probe Precise, robust NTC air probe External vacuum probe Please contact Testo Service. For a complete list of all accessories and spare parts, please refer to the product catalogues and brochures or look up our website at: 24
25 9 EC Declaration of Conformity 9 EC Declaration of Conformity 25
26 en 01 V01.00
Measurement Solutions for Refrigeration Technology.
Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. Testo refrigeration technology Digital is better: Refrigeration technology expertise
it500 Internet Thermostat INSTALLER MANUAL
it500 Internet Thermostat INSTALLER MANUAL 1. Product compliance & safety information These instructions are applicable to the SALUS Controls model stated on the front cover of this manual only, and must
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
CONTENTS --------------------------------------------------------------------------------------
en WiFi USB DONGLE CONTENTS -------------------------------------------------------------------------------------- 9 SAFETY AND SET-UP 10 WiFi USB DONGLE 10 Packing contents 10 Special features 10 Connection
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
Druck PV 62x pneumatic/hydraulic pressure stations
GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Jabra LINK 220 Jabra LINK 220a
Jabra LINK 220 Jabra LINK 220a USER MANUAL www.jabra.com 1 2009 GN Netcom A/S. All Rights Reserved. This user guide is published by GN Netcom A/S. The information in this user guide is furnished for informational
Highly efficient flue gas analyzer
Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2
Installation and Operating Manual p. 23 Radio push button 2 channel: HM-PB-2-WM55-2 1. English edition 10/2013 Documentation 2013 eq-3 Ltd., Hong Kong All rights reserved. No parts of this manual may be
e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL
Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
testo 6721 Dew point monitor P2A software for testo 6721 Instruction manual
testo 6721 Dew point monitor P2A software for testo 6721 Instruction manual en 2 Contents 3 Contents de Contents 3 Safety and the environment 4 Part 1: testo 6721 Specifications 5 Commissioning 8 Assembling
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
Turbocharger system components, servicing
21-1 Turbocharger system components, servicing Engine codes: AAZ, 1Z, AHU Observe rules of cleanliness Page 21-10 Turbocharger hoses and lines, connecting Page 21-11 WARNING! Do not re-use any fasteners
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
Hand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented
User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non- Contact IR Thermometer,
Thermistor Thermometer MODEL NO. 93210-00
Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:
RS DIGITAL THERMOMETER
RS DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL C F MX MN AVG TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION... 1 2. SPECIFICATIONS... 1 3. NAME OF PARTS AND POSITIONS... 3 4. OPERATION INSTRUCTIONS... 5
Machine needle shut-off nozzle type HP
Machine needle shut-off nozzle type HP pneumatically or hydraulically controlled Index of contents Chapter Page Safety instructions... 2 Installation instructions... 3 - Installation steps... 3 Initial
Nokia Wireless Keyboard (SU-8W) User Guide
Nokia Wireless Keyboard (SU-8W) User Guide DECLARATION OF CONFORMITY We, NOKIA CORPORATION declare under our sole responsibility that the product SU-8W is in conformity with the provisions of the following
Model 2128 AIR COMPRESSOR PUMP Operating Instructions
Model 8 AIR COMPRESSOR PUMP Operating Instructions Assembly of pump Connection to cylinder and charging ) Connect the air hose to the air cylinder and tighten with spanner. Do not over tighten. Note; the
NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE EUROPEAN UNION 1 Quarter 4 2015
NEW PASSENGER CAR REGISTRATIONS BY ALTERNATIVE FUEL TYPE IN THE Quarter 4 2015 Alternative fuel vehicle (AFV) registrations: +20.0% in 2015; +21.1% in Q4 In the fourth quarter of 2015, total alternative
MME TECHNICAL SERVICE NEWSLETTER GROUP 16 ALTERNATOR LOOSE PULLEY _ 4N13 DATE 12 06-2012 SERVICE CAMPAIGN (REF. MMC: SSI-12-023)
MME TECHNICAL SERVICE NEWSLETTER NEWSLETTER MODEL ENL-12-018-SC ASX (GA6W) GROUP 16 SUBJECT ALTERNATOR LOOSE PULLEY _ 4N13 DATE 12 06-2012 SERVICE CAMPAIGN (REF. MMC: SSI-12-023) På grund av felaktig åtdragning
WSD130 SOLDERING STATION
NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch
el-720 Carbon Dioxide Gas Leak Detector User s Guide
el-720 Carbon Dioxide Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind.
EM6625 e-domotica Push Button
EM6625 e-domotica Push Button EM6625 e-domotica Push Button 2 ENGLISH Table of contents 1.0 Introduction... 2 1.1 Functions and features... 2 1.2 Packing contents... 2 2.0 Inserting or replacing the battery...
Volkswagen Golf 5 2004-> VW Rabbit GTI 2006->
Стр. 1 из 24 Volkswagen Golf 5 2004-> VW Rabbit GTI 2006-> 19-1 Cooling system components Warning! Hot steam may escape when opening expansion tank. Wear protective goggles and protective clothing to prevent
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
External Hard Drive esata & USB 2.0 Combo. User Guide English
External Hard Drive esata & USB 2.0 Combo User Guide English Contents Introduction 3 Controls, Connectors and Indicators 3 Front Panel Area 3 Rear Panel Area 3 About the Hard Drive 4 Locating the Drive
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
Recharge Procedure for Telemark TVP-2000 and TVP-3500
Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
USER GUIDE. LED Light Meter. Model LT45
USER GUIDE LED Light Meter Model LT45 Introduction Congratulations on your purchase of the Extech LT45 LED Light Meter that measures light from LED lamps in addition to fluorescent, metal halide, high
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
by QUICK START GUIDE 1
by QUICK START GUIDE 1 BUTTONS & CONTROLS TALK* PREVIOUS / NEXT* POWER BUTTON & LED PAIRING BUTTON LINE IN USB DC IN PLAY / PAUSE* VOLUME DOWN / UP * Only works when connected wirelessly via Bluetooth
evohome Wireless Radiator Zoning Kit Installation & User Guide
evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome
Leica DISTO TM D210 The original laser distance meter
Leica DISTO TM D0 The original laser distance meter Table of Contents Instrument Set-up - - - - - - - - - - - - - - - - - - - - - - - - - - Overview - - - - - - - - - - - - - - - - - - - - - - - - - -
Operating instructions Cordless K 10253 impact wrench
Operating instructions Cordless K 10253 impact wrench Operational precautions General safety instructions warning! 1. Consider work area environment. Do not expose tools to rain. Do not use tools in damp
Instructions For SF 6 Refill Kit
S&C Vista Underground Distribution Switchgear UnderCover, Vault-Mounted, and Pad-Mounted Styles Instructions For SF 6 Refill Kit TABLE OF CONTENTS Section Page Section Page INTRODUCTION..................................
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions
MAKING MODERN LIVING POSSIBLE living connect Installation and User Guide Danfoss Heating Solutions 2 living connect Thank you for buying a Danfoss product Danfoss Heating Solutions 3 Contents 1. System
ERASMUS+ MASTER LOANS
ERASMUS+ MASTER LOANS Erasmus+ Master Loan: opening up access to more affordable lending for cross-border studies The Erasmus+ programme makes it possible for students who want to take a full Masters level
7 FUNCTION DIGITAL MULTIMETER
7 FUNCTION DIGITAL MULTIMETER 90899 OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All rights
4P359542-1H. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual
4P359542-1H Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com For details
Dual Laser InfraRed (IR) Thermometer with Color Alert
User Manual Dual Laser InfraRed (IR) Thermometer with Color Alert MODEL 42509 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer
01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
User Guide. Soft-Touch TM Bluetooth Laser Mouse N2953
Soft-Touch TM Bluetooth Laser Mouse 410-XXXXXXXXXXX 1 YEAR LIMITED WARRANTY: We pride ourselves on the quality of our products. For complete warranty details and a list of our worldwide offices, please
Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394
GE Industrial Sensing 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Druck DPI 104 Digital pressure indicator User manual - K394 A1.1 A1.2 B1 1 A2 B2 2 3 4 5 6 A1.3 8 7
How to connect your D200 using Bluetooth. How to connect your D200 using GPRS (SIM Card)
D200 En User Guide Content 3 Introduction 3 Scope 3 Related Documentation 4 Internet Connectivity 4 Using D200 with Mobile Phone 5 Using D200 with wireless (Wi-Fi) router 6 Using D200 with GPRS (requires
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information
Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information en Contents Instrument description...3 User instructions...4 Safety instructions...5 Folding ferrite...5 Operating instructions...6
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
ERASMUS+ MASTER LOANS
Ref. Ares(2015)660570-17/02/2015 ERASMUS+ MASTER LOANS Erasmus+ Master Loan: opening up access to more affordable lending for cross-border studies The Erasmus+ programme makes it possible for students
User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN
User's Guide Digital Psychrometer Model RH390 MAX MIN F C WBT Dew Point Introduction Congratulations on your purchase of the Extech RH390 Digital Psychrometer. This device measures Humidity, Air Temperature,
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
FMT600BT Transmitter
Technaxx FMT600BT Transmitter User Manual Transfer of music and calls directly from your Bluetooth device to your car radio This device complies with the requirements of the standards referred to the Directive
COMMUNICATION FROM THE COMMISSION
EUROPEAN COMMISSION Brussels, 17.9.2014 C(2014) 6767 final COMMUNICATION FROM THE COMMISSION Updating of data used to calculate lump sum and penalty payments to be proposed by the Commission to the Court
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Temperature Humidity Meter
971 Temperature Humidity Meter Users Manual PN 2441047 September 2005 Rev.1, 5/06 2005-2006 Fluke Corporation, All rights reserved. Printed in Taiwan All product names are trademarks of their respective
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
CG-1171-20 PTFE Diaphragm Liquid Transfer Pump
3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
Digital Air Pressure Gauge Users Manual
Digital Air Pressure Gauge Users Manual Intercomp Co. 3839 County Road 116 Medina, MN 55340, U.S.A. (763)-476-2531 1-800-328-3336 Fax: 763-476-2613 www.intercompracing.com Manual #: 700099 Rev H Table
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Michelin User Guide. Hi-power Rapid Tyre Inflator
12262 Michelin User Guide Hi-power Rapid Tyre Inflator Thank you for purchasing the Michelin High-power Rapid Tyre Inflator. Please read the operating instructions carefully before using your tyre inflator.
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No. 91905 User s Manual
WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER Model No. 91905 User s Manual BASE STATION REMOTE SENSOR FEATURES AND SPECIFICATIONS BASE STATION Indoor / wireless outdoor temperature, C / F selectable Indoor
Cooling system components, removing and installing
Volkswagen Touareg 3.2 - Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! Hot steam may escape when opening expansion tank.
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
Nokia Bluetooth Headset BH-118 User Guide
Nokia Bluetooth Headset BH-118 User Guide Issue 1.1 2 Contents Introduction 3 About your headset 3 About Bluetooth connectivity 3 Get started 4 Keys and parts 4 Charge the battery 4 Switch the headset
Rapier V1. Laser Gaming Mouse. User Guide English
Rapier V1 Laser Gaming Mouse User Guide English Contents Welcome 3 Whats in the Pack 3 Key Features 3 Button Assignment 3 Rapier V1 Installation 4 Software Introduction 4 Rapier V1 Gamer Toolkit 4 Funtion
MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.
MX MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)
INSTRUCTION MANUAL ➏ ➋ ➊ Product Features ➎ ➍ ➌ Built-in wireless Bluetooth 3.0 keyboard Compatible across ios, Android, and Windows, enabling you to mix and match with devices Ultra-thin, lightweight
Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1
REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com