1 1762 Clifton Road, Suite 1200 Atlanta, Georgia (404) FAX: (404) GUIDELINES FOR CHEMICAL WASTE MANAGEMENT IN LABORATORIES PURPOSE The purpose of this document is to provide guidance for the safe storage and disposal of Chemical Waste generated in laboratories at Emory University, including laboratories at Oxford Campus, Emory Healthcare, and Yerkes National Primate Center. Radiological and Biological waste guidance is provided in separate guidance documents. Please consult with the Environmental Health and Safety Office (EHSO) website for further guidance. Federal, state, and local governments impose strict regulations concerning the management, storage, and disposal of hazardous materials. Improper handling and disposal is a violation of regulations and can result in penalties. Contents IDENTIFYING CHEMICAL WASTE IN YOUR LABORATORY... 2 STORING CHEMICAL WASTE IN YOUR LABORATORY... 5 DISPOSING OF CHEMICAL WASTE... 8 MINIMIZING CHEMICAL WASTE IN YOUR LABORATORY... 9 HIGHLY HAZARDOUS CHEMICALS AND CHEMICAL SPILLS ADDITIONAL CHEMICAL WASTE GUIDANCE QUICK FACTS FOR CHEMICAL WASTE DISPOSAL IN LABORATORIES Related Documents ETHIDUM BROMIDE DISPOSAL GUIDELINES CHEMICAL DISPOSAL INVENTORY FORM CHEMICAL WASTE LABEL FLOW CHART FOR DETERMINING CHEMICAL WASTE CLASSIFICATION Chemical Waste Disposal Guidelines_7 22-Feb-12 page 1 of 16
2 IDENTIFYING CHEMICAL WASTE IN YOUR LABORATORY DEFINITION OF HAZARDOUS WASTE EHSO is responsible for operating the Chemical Waste Management Program at Emory University. EHSO makes the final determination if a chemical is an Environmental Protection Agency (EPA) regulated Hazardous Waste. A material becomes a waste when it has no further economic value regardless of whether or not it has been used or contaminated. Spilled chemicals and absorbent materials used to clean a spill must be handled as a chemical waste. NOTE: Material can include used and unused reagents such as ethidium bromide gels, paints, solvents, disinfectants, batteries, aerosols, filters, lamps, and other similar items in addition to stock chemicals and chemical solutions used in laboratory processes. Hazardous wastes are defined by the EPA as materials that exhibit a characteristic of hazardous waste or it is listed specifically by the EPA as hazardous waste. Each hazardous waste type is described in detail below. CHARACTERISTIC HAZARDOUS WASTES Waste solids, liquids, or containerized gases that exhibit any of the following characteristics are defined as characteristic hazardous wastes: 1) Ignitability; 2) Corrosivity; 3) Reactivity; or 4) Toxicity. A detailed discussion of characteristic waste is available at: LISTED HAZARDOUS WASTES The EPA has already determined that certain chemicals are hazardous and has incorporated these into complete published lists. The complete lists can be viewed by accessing the following website: K-Listed Hazardous Wastes K-listed hazardous wastes are source-specific wastes that are generated by specific industries such as iron and steel production facilities, and are not likely to be found in a laboratory. F-Listed Hazardous Wastes F-listed hazardous wastes are non-source specific wastes that are generated by common processes that can occur in various applications, including processes that generate spent solvents, electroplating and other metal finishing processes. F-listed wastes that may be found in laboratories include but are not limited to the following solvents or mixtures containing 10 percent or more of the solvent before use. See Table 1. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 2 of 16
3 Table 1: Examples of F-listed chemicals found in laboratories 1,1,1- trichloroethane 1,1,2- trichloroethane 2-ethoxyethanol 2-nitropropane Acetone Benzene Carbon disulfide Carbon tetrachloride Chlorinated fluorocarbons Cresols Cresylic acid Cyclohexanone Ethyl acetate Ethyl benzene Ethyl ether Isobutanol Methanol Methylene chloride Methyl ethyl ketone n-butyl alcohol Nitrobenzene Tetrachloroethylene Toluene Orthodichlorobenzene Trichloroethylene Pentachlorophenol Trichlorofluorometh ane Methyl isobutyl ketone Pyridine Xylene P-Listed Hazardous Wastes The P-listed hazardous wastes are commercial grade formulations of specific unused chemicals. Unused chemicals may be considered wastes because they are no longer needed, they are spilled, or they are off-specification. Please note that containers that held P-listed chemicals must be disposed of through EHSO. There are over 100 P-listed hazardous wastes. The P-listed chemicals most commonly found in laboratories include the following: Table 2: Examples of P-listed chemicals found in laboratories Acrolein Allyl alcohol Ammonium vanadate Arsenic acid Carbon disulfide Chloroacetaldehyde Chloroaniline Cyanides Brucine Diisopropylfluoroph osphate 2,4-Dinitrophenol p-nitroaniline Phosgene Potassium cyanide Sodium azide Sodium cyanide Osmium tetroxide Thallium oxide Vanadium pentoxide Epinephrine Nicotine Chemical Waste Disposal Guidelines_7 22-Feb-12 page 3 of 16
4 U-Listed Hazardous Waste The U-Listed Hazardous wastes are commercial grade formulations of specific unused chemical. Unused chemicals may be considered wastes because they are no longer needed, spilled or offspecification. There are over 300 U-listed hazardous wastes. The U-Listed chemicals most likely found in laboratories include the following: Table 3: Examples of U-listed chemicals in laboratories Acetaldehyde Pyridine 2-Propanone Acetone Acetonitrile Cacodylic acid Acrylamide Acrylonitrile Aniline Benzene 1-Butanol Chlorobenzene Chloroform Hydrofluoric acid Cresol Cyclohexane Cyclohexanone Dichlorobenzene Ethylene dichloride 1,2- Dichloroethylene Methylene chloride 2,4-Dichlorophenol 1,4-Dioxane Ethyl acetate Ethyl ether Trichloromonofluor omethane Formaldehyde Formic acid Hydrazine Isobutyl alcohol Lead acetate Mercury Methanol Methyl ethyl ketone Methyl isobutyl ketone Triethylamine Methyl methacrylate Naphthalene Phenol Resorcinol 1,1,1,2- Tetrachloroethane 1,1,2,2- Tetrachloroethane Tetrachloroethylene Carbon tetrachloride Tetrahydrofuran Trypan blue Thiourea Toluene Xylene Trichloroethylene Universal Waste Universal Waste is waste that meets the EPA s definition of hazardous waste, but is found so abundantly that they drafted different rules for handling and managing it. Universal waste includes most batteries (excludes alkaline batteries), lamps, mercury containing articles and some pesticides. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 4 of 16
5 STORING CHEMICAL WASTE IN YOUR LABORATORY CHEMICAL WASTE CONTAINERS Chemical waste must be stored in containers (including lids) composed of materials that are compatible with the waste. Chemical waste containers must be in good condition and free of leaks and residue on the outside of the container. Appropriate containers can be obtained from EHSO. For liquids, fill containers to about 90% of container volume. Do NOT fill containers to the top. Leave at least 2 inches of space in liquid waste containers to allow for liquid expansion and decanting. SEALING CHEMCIAL WASTE CONTAINERS Chemical waste containers must be tightly closed to prevent leakage or spillage. Containers should be closed with a screw-type lid or other appropriate device. Plastic wrap, aluminum foil, parafilm and other make-shift lids are unacceptable. A container holding chemical waste must ALWAYS be closed, except when waste is actually being added. If a waste container is used to collect waste from a continuous process (i.e., drainage from a process collected with tubing inserted into a bottle such as HPLC), the container must still be sealed using rubber stoppers with tubing inserts or other appropriate means. It is not acceptable to leave funnels in chemical waste containers. LABELING CHEMICAL WASTE CONTAINERS All chemical waste containers must be labeled with the Chemical Waste Label. These labels are available on the EHSO web site. EHSO provided containers will have the appropriate label affixed when given. The following information must be provided on the label (see example of the label later in this section): PI Name or Department Head Building Room number Telephone number Exact contents of the container It is important to include as much information as is known about the contents of the chemical waste container, including percentages and water content, to facilitate disposal. Example: Chemical Waste Label Chemical Waste Disposal Guidelines_7 22-Feb-12 page 5 of 16
6 No additional labeling is necessary for surplus chemicals if the original label is intact and legible. Other waste containers, such as suction flasks used for collecting non-chemical waste, should be labeled with the specific type of waste collected (example: Cell Culture Media Waste ). It is not necessary to use EHSO Chemical Waste Labels for the labeling of this type of waste. MIXING WASTE CHEMICALS Consult with EHSO prior to mixing different chemical wastes. Mixing a hazardous waste with a non-hazardous waste may increase the volume of hazardous waste for disposal or increase disposal costs due to differences in disposal options for certain hazardous wastes. Mixing incompatible materials may be dangerous. DO NOT mix incompatible materials in the same container. CHEMICAL WASTE CONTAINER STORAGE A specific area should be designated in the laboratory as a chemical waste storage area. Waste must be stored in the room it was generated in and cannot be transferred to any area that requires passage through a door. Chemical waste must be stored with secondary containment so that spills cannot reach sinks, or floor drains. Incompatible chemical wastes must be segregated to prevent reaction. Segregation methods include storing in separate cabinets or separate secondary containment containers such as 5-gallon buckets or tubs. Refer to the quick reference chart posted in your lab, Incompatibility of Common Laboratory Chemicals. You must also consider your storage capacity when establishing your storage area. You must not store chemical waste in quantities that prevent proper storage practices. Based on your laboratory s rate of generation of chemical waste, your storage capacity, and keeping in mind the quantity limits described below, you must determine the amount of chemical waste you will accumulate in your storage area. Proper Chemical Waste Storage Improper Chemical Waste Storage Waste must be stored in EHSO provided containers, properly labeled, and segregated by compatibility. Liquid waste must be stored in secondary containment. The waste is NOT properly labeled, segregated by compatibility, closed or stored in secondary containment. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 6 of 16
7 CHEMICAL WASTE STORAGE LIMITS Your laboratory must NOT store more than 5 gallons (20 liters) of chemical waste in a single container, one quart of P-listed waste, or a total of 50 gallons of all wastes at one time. Chemical waste must be removed at a frequency that prevents the lab from exceeding these limits. Exceptions to these limits must be approved by EHSO. If these limits are ever exceeded, you must immediately contact EHSO for removal. Refer to the Identifying Chemical Wastes in Your Laboratory section of these guidelines for the definition of P-listed chemicals. Laboratories should try to minimize storage of chemical waste and not accumulate waste after filling. When a container is filled it must be removed as soon as possible. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 7 of 16
8 DISPOSING OF CHEMICAL WASTE CHEMICAL WASTE COLLECTION PROGRAM All chemical waste generated by Emory University MUST be managed by EHSO. In general, laboratories are not directly charged for this service so long as these guidelines are followed. CHEMICAL WASTE PICK UP PROGRAM All chemical waste will be picked up by EHSO per specific building schedule. The Chemical Disposal Inventory Form must accompany all waste and surplus chemicals for potential reuse by other Emory laboratories. Chemicals must never be transported in personal vehicles. Only EHSO may transport chemical waste in approved University vehicles. Chemicals must NOT be disposed of by evaporation. This includes evaporation in fume hoods or biosafety cabinets. Remember, chemical waste containers must be kept closed at all times except when actually adding chemical waste. CONTAINER DISPOSAL Empty plastic and brown glass chemical containers may be rinsed with water and recycled or disposed of. Caps must be removed and labels defaced. Chemical containers must be triple rinsed with water prior to disposal. The rinsates may be disposed of via the sink drain. Note: Containers that held EPA Registered Pesticides or P-listed chemicals must be disposed of through EHSO and may not be rinsed and/or recycled. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 8 of 16
9 MINIMIZING CHEMICAL WASTE IN YOUR LABORATORY CHEMICAL REDISTRIBUTION EHSO has a Chemical Redistribution Program where unwanted but useable reagents are made available to other Emory laboratories. Surplus chemicals are available at: Woodruff Memorial Research Building Whitehead Biomedical Research Building L302 G44 Contact EHSO at for information. PRODUCT SUBSTITUTION Laboratories should attempt to substitute non-hazardous or less toxic materials into their processes and experiments whenever possible. One example is non-hazardous xylene or ethidium bromide substitutes. Please refer to scientific equipment vendors for Green chemicals. INVENTORY MANAGEMENT AND CONTROL Laboratories should periodically evaluate their chemical inventory and dispose of unwanted/obsolete chemicals. Purchase only the quantity of chemicals required for specific projects. Ordering bulk quantities of chemicals may cost more when disposal of the excess quantity is considered. PROCESS MODIFICATION To the extent that it does not affect vital research or teaching, laboratories should modify experiments to decrease the quantity of chemicals used and generated. Microanalysis techniques can greatly reduce the amount of chemical waste generated. SEGREGATION To the extent possible, do not mix wastes or waste streams. In particular, do not mix nonhazardous waste with hazardous waste. NEUTRALIZATION AND RECLAMATION Some laboratories generate a simple, pure chemical stream, such as a dilute acid or base that can be rendered non-hazardous by simple neutralization. Other laboratories may generate a dilute aqueous stream that contains a metal that can be easily precipitated, rendering the waste stream non-hazardous. Additionally, reclamation systems are available for some waste streams such as silver recovery systems for photograph fixer solutions. Strict laws apply to processes for neutralizing hazardous wastes. For these types of waste streams, labs must contact EHSO to determine if the neutralization or reclamation is an acceptable method of rendering a chemical non-hazardous. GOOD HOUSEKEEPING PRACTICES Good housekeeping practices minimize the likelihood of a spill and can reduce the amount of waste generated. Spilled chemicals and the materials used to clean up the spills must be disposed of as chemical waste. SINK DISPOSAL OF CHEMICAL SUBSTANCES Buildings on the Emory University Campus are connected to the Dekalb County Publicly Owned Chemical Waste Disposal Guidelines_7 22-Feb-12 page 9 of 16
10 Treatment Works (POTW), i.e. sanitary sewer, and thus need to follow county codes as well as state and federal requirements. Prohibited Discharge Substances: The following substances are prohibited (in any amount or concentration), from sink or drain disposal. Dilution of substances for wastewater disposal purposes is strictly prohibited. The following general categories of chemicals may not be disposed of in the sewer: Hazardous wastes Chlorinated Hydrocarbons Chlorofluorcarbons Brominated Hydrocarbons Cyanides Heavy Metals (Arsenic, barium, cadmium, chromium, lead, mercury, selenium, silver, etc.) Corrosives (ph < 5.0 or > 11.5) Organic Solvents Oil and Grease (petroleum, vegetable, mineral, wax, fats, etc.) Ignitable Chemicals Reactive Chemicals Solid or Viscous Waste (at > 32 F) Nuisance Chemicals (cause odors or discoloration) Hot Liquid or Vapor Waste Ethidium Bromide or Acrylamide Priority Pollutants (See Table 1 of Guidance for Sink Disposal of Chemical Substances) Unused or Pure Chemicals: Unused, pure, or concentrated chemicals may never be disposed of in the sanitary sewer. Acceptable Substances for Drain Disposal There are a limited number of substances acceptable for drain disposal, providing the solution does not contain material otherwise prohibited. These substances include: Aqueous solutions such as salts or buffer solutions within the ph range of 5.0 to Aqueous solutions with a flashpoint greater than 140 F (60 C). Chemicals that are water soluble and not hazardous by definition. Biological liquids that have been treated with disinfectant or autoclaved. Buffer solutions containing less than 10 µg/ml of ethidium bromide. Aqueous solutions containing alcohols at a concentration of 20 % weight or less. Aqueous solutions containing formalin at concentrations of 10 % by weight or less. Small quantities of acids or bases that have been neutralized in the laboratory. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 10 of 16
11 HIGHLY HAZARDOUS CHEMICALS AND CHEMICAL SPILLS HIGHLY HAZARDOUS CHEMICALS Certain chemicals must be handled by special procedures due to their highly hazardous nature. These chemicals include expired ethers and other peroxide forming compounds, dry picric acid, dry 2, 4-dinitrophenylhyrdazine, or dry benzoyl peroxide. These chemicals can explode during opening or routine handling. If you have any questions regarding highly hazardous chemicals, contact EHSO. If you encounter these or other highly hazardous chemicals in your laboratory, do not disturb them and immediately notify EHSO to arrange for disposal. Highly hazardous chemicals must NOT be handled by laboratory personnel. Expired Ethyl Ether Expired ethyl ether is one of the most common highly hazardous chemicals found in laboratories. Ethyl ether is extremely flammable and can form explosive peroxides after exposure to air and light. Since it is packaged in an air atmosphere, peroxides can form even in unopened containers. Therefore, it is very important to write the date received and the date opened on all ether containers. Opened containers should be disposed of through the EHSO within 6 months of opening. Unopened containers should be disposed of through the EHSO within 12 months of receipt. Ethers should be purchased in the smallest container practical and be stored away from heat, sunlight and any source of ignition in a flammable storage cabinet or refrigerator/freezer certified for storing flammable materials. CHEMICAL SPILLS Chemical spills must be cleaned up immediately. Spill clean-up debris must be treated as chemical waste. Chemical spills that cannot be safely mitigated by laboratory personnel are considered major spills and should immediately be reported to EHSO or Emory Police. Call EHSO at during normal business hours (9 AM -5 PM). All other times call Emory Police at 911 from any campus phone or Refer to the Office of Critical Events Preparedness and Response (CEPAR) Just-In-Time Guide to Campus Emergencies. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 11 of 16
12 ADDITIONAL CHEMICAL WASTE GUIDANCE 1. Multi Hazard Waste: Multi-hazard waste is waste that contains any combination of chemical, radioactive, or biological hazards. Although many of the principles discussed for chemical waste also apply here, multi-hazard waste requires special management considerations because the treatment method for one of the hazards may be inappropriate for the treatment of another. Many types of mixed waste management is excessively expensive and difficult and therefore its generation should be avoided. Contact EHSO for additional guidance. Chemical-Radioactive (mixed) waste is defined by the EPA as "wastes that contain a chemically hazardous waste component regulated under the Resource Conservation and Recovery Act (RCRA) and a radioactive component consisting of source, special nuclear, or byproduct material regulated under the Atomic Energy Act." Disposal options for mixed waste are usually very expensive. Materials of this type must be delivered to EHSO under the guidelines described in the Radiation Safety Manual. The biological and chemical contaminants must be listed under the Hazard section on the Radioisotope Waste Inventory Form. An exception to this rule includes uranyl nitrate and uranyl acetate compounds, which are disposed of as chemical waste. Examples of laboratory mixed wastes include: a. Used flammable liquid scintillation cocktail b. Phenol-chloroform mixtures from extraction of nucleic acids from radio labeled cell components c. Certain gel electrophoresis waste (e.g., methanol or acetic acid containing radio nuclides) d. Lead contaminated with radioactivity 2. Unknowns: Labs must make every attempt to identify an unlabeled or unknown compound. If unable to do so, the material should be labeled as unknown, included on the Chemical Disposal Inventory Form and delivered to EHSO for disposal. 3. Empty Containers: Empty chemical containers may be disposed of in the regular trash or by recycling after following the triple-rinsing procedure, defacing labels and removing caps. If these containers previously held P-listed compounds or EPA Registered pesticides then the bottle must be disposed of by EHSO. 4. Mercury: a. Mercury Containing Articles: Metallic mercury is most commonly found in thermometers, thermostats, sphygmomanometers, pressure gauges and in some larger pieces of equipments, such as cell counters. These apparatuses should be removed from service and disposed of by EHSO. Unwanted mercury containing articles must be labeled Used Mercury Containing Equipment, dated the day it was removed from service, and packaged so as to prevent damage or breakage. Small articles such as thermometers must be packaged in a box that is securely taped closed and disposed of through EHSO as chemical waste. Contact EHSO directly for larger pieces of equipment. b. Mercury Solutions: solutions that contain mercury compounds must be kept separate from other chemical waste. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 12 of 16
13 c. Broken/Damaged Mercury Thermometers: Collect elemental mercury and glass from broken or damaged thermometers in an impermeable container such as a polyethylene container or sealable bag. Label the container as broken mercury thermometer. Contact EHSO for assistance or to verify if clean-up was sufficient. 5. Compressed Gas Cylinders and Lecture Bottles: When cylinders have been emptied, they should be labeled EMPTY and returned to the vendor from where they were obtained. Many vendors no longer accept lecture bottles back for return because they are not refillable. It is recommended these either be used up completely, or not purchased at all due to excessive disposal costs. If a cylinder or lecture bottle cannot be returned to the vendor, contact EHSO. 6. Aerosol Cans: Aerosol cans present a unique hazard in that the pressurization of the container is oftentimes more dangerous than the compound within. Therefore, all aerosol cans, whether full or empty must be delivered to EHSO for disposal as chemical waste. 7. DEA Scheduled Drugs: These items can only be purchased under licensure from the Drug Enforcement Administration and the Georgia State Board of Pharmacy the disposal of this cannot be handled at EHSO. The licensee must dispose of scheduled drugs via the methods described under their licensee. Additional information may be found in the Policy for Use of Controlled Substances 8. Chemotherapy Waste: Antineoplastic or cytotoxic agents are extremely toxic and must be disposed of properly. This waste includes expired drugs as well as any contaminated debris such as syringes (but no needles). Chemotherapeutic waste that is generated during patient use must be disposed of through the usual Emory Healthcare disposal procedures. However, there are a few antineoplastic compounds that are included in the EPA Listed Hazardous Wastes that must be disposed of as Regulated Chemical Waste. These include but are not limited to: Chlorambucil, Cyclophospamide, Daunomycin, Melphalan, Mitomycin C, Streptozotocin, and Uracil Mustard. 9. Ethidium Bromide Waste: Refer to the Ethidium Bromide Waste Disposal Guidelines on the EHSO website. 10. Oil: Varying processes use different types of oils around campus. These include HVAC operations, refrigerators, laboratory equipment, etc. Make special note of older oils found as these may contain Polychlorinated Biphenyls (PCBs). All containers of waste oil must be labeled Used Oil and disposed as chemical waste. 11. Polychlorinated Biphenyls (PCBs): PCBs present a unique disposal concern as they are regulated differently than other chemicals. In the laboratory, PCBs can be found in older immersion oils and are occasionally used in research. PCBs should not be mixed with other regulated chemicals. All items containing or suspected of containing PCBs must be disposed of by EHSO. 12. Formalin and Formaldehyde Solutions: Dilute formaldehyde solutions should be stored for disposal as chemical waste. Formaldehyde is a suspected carcinogen with a low permissible exposure limit (PEL). Chemical Waste Disposal Guidelines_7 22-Feb-12 page 13 of 16
14 13. Ignitable Liquids and Organic Solvents: Separate organic solvents from aqueous solutions whenever possible. Keep acidified solvents separate from other solvent and acid wastes. 14. Acids, Bases, and Aqueous Solutions: Do NOT mix strong inorganic acids or oxidizers with organic compounds. Keep acids, bases and aqueous solutions containing heavy metals separate from other chemical waste. Avoid mixing concentrated acids and bases together in the same container. 15. Corrosive Materials: The following corrosive liquids shall not be mixed with any other chemical waste under any circumstances. a. Nitric acid exceeding 40 percent concentration b. Perchloric acid c. Hydrogen peroxide exceeding 52 percent strength by weight d. Nitrihydrochloric or Nitrohydrochloric acid diluted 16. Perchloric Acid and Perchlorates: Keep perchloric acid and perchlorate wastes separate from other wastes and in exclusive containers. 17. Toxic Wastes: Separate toxic wastes from other chemical waste whenever possible. For example, do not mix aqueous waste containing heavy metals with wastes that do not. Mercury containing waste requires additional diligence in separation. 18. Explosive Materials: Potentially explosive materials, such as dry picric acid or peroxide forming compounds must be handled by EHSO. 19. Pesticides and Herbicides: Whenever possible, pesticides and herbicides should be used up completely. Be sure to check the list of regulated chemicals or the bottle for an EPA Registration Number (EPA Reg. No.) or contact the EHSO before disposing of empty containers as they may likely be considered regulated waste and must be disposed of as such. Any unused pesticides and herbicides must also be disposed of as chemical waste. 20. Asbestos: Asbestos may be found in many building materials such as floor and ceiling tiles, countertops, moldings, or liners of chemical fume hoods, as well as laboratory equipment like tong holders or high temperature gloves. Only trained personnel should conduct renovation of or around asbestos. If you have a particular concern about the possibility of asbestos in your building, or wish to dispose of equipment that may have asbestos in it, please contact the Safety and Industrial Hygiene Program ( ). 21. Cleaning Products: Whenever possible, cleaning products should be used completely. Many cleaning products are corrosive in their undiluted state and must be disposed of as chemical waste. Some disinfectants may have an EPA Reg. No. on the container. If this is the case, then the empty container or unused product should be disposed of through EHSO. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 14 of 16
15 22. Bulbs and Lamps: Bulbs and lamps from microscopes, biosafety cabinets, or other equipment may contain mercury or other hazardous metals and must be disposed of through EHSO as chemical waste. Spent lamps must be labeled Used Lamp(s) s, dated the day it was removed from service, and packaged in a box that is securely taped closed to prevent damage or breakage. 23. Batteries: All batteries except standard dry cell alkaline must be disposed of through the EHSO. This includes lead acid, lithium ion (Li), lithium hydroxide (LiH), mercury, nickel, silver cell, cadmium (NiCad) or nickel hydride (NiH) batteries. Used batteries must have their terminals covered with non-conductive tape, be labeled Used Battery(ies), dated the day it was removed from service, and packaged in a box that is securely taped closed to prevent damage or breakage. Chemical Waste Disposal Guidelines_7 22-Feb-12 page 15 of 16
16 QUICK FACTS FOR CHEMICAL WASTE DISPOSAL IN LABORATORIES IDENTIFYING CHEMICAL WASTE IN YOUR LABORATORY Treat all waste chemical solids, liquids, and containerized gases as chemical waste STORING CHEMICAL WASTE IN YOUR LABORATORY Store chemical waste in sealed and compatible containers Chemical waste containers must be kept closed at all times except to add waste Label chemical waste containers with EHSO chemical waste label as soon as waste accumulation begins Store chemical waste with secondary containment Segregate incompatible chemical waste Never accumulate more than 5 gallons of chemical waste in a single container or one quart of acute hazardous waste, or 50 gallons total of all waste NOTE: Laboratories should try to minimize storage of chemical waste and not accumulate waste for longer than 30 days after filling. DISPOSING OF CHEMICAL WASTE IN YOUR LABORATORY Utilize the EHSO Chemical Waste Program to dispose of chemical waste Complete the Chemical Disposal Inventory Form Ensure all items on the Chemical Waste Label are completed Never evaporate chemicals as a disposal method Deface labels from empty chemical containers Chemical containers must be triple rinsed with water prior to disposal. The rinsates may be disposed of via the sink drain. NOTE: Containers that held EPA Registered Pesticides or P-listed chemicals must be disposed of through EHSO and may not be rinsed and/or recycled. CHEMICAL WASTE MINIMIZATION Check the Chemical Redistribution Program before ordering new chemicals Order only the quantity of chemicals you need Utilize inventory management and control to prevent buildup of waste chemicals Substitute non-hazardous or less hazardous chemicals and/or modify your process to use smaller quantities of hazardous chemicals whenever possible Utilize good housekeeping practices to minimize the risk of a spill Chemical Waste Disposal Guidelines_7 22-Feb-12 page 16 of 16
Hazardous Waste Containers. Hazardous Waste Disposal. Examples of HW Containers. Typical Wastes in Chemistry
Hazardous Waste Initial Training Brian Smith, Hazardous Waste Coordinator Environmental Health and Safety Michigan State University THE Absolute Three Things you need to stay out of trouble: Words Hazardous
HAZARDOUS WASTE MANUAL For Faculty, Staff, and Students
Click Here to go to the Table of Contents Department of Chemical Engineering Michigan Technological University Houghton, MI HAZARDOUS WASTE MANUAL For Faculty, Staff, and Students Chemical Hygiene Officer:
Handling of Specific Chemicals
Handling of Specific Chemicals 1) ACETONITRILE 2) CARCINOGENS, MUTAGENS, TERATOGENS 3) COMBUSTIBLE LIQUIDS 4) CONTAMINATED CONTAINERS 5) CONTAMINATED EQUIPMENT 6) CORROSIVE ACIDS AND BASES 7) EXPLOSIVES
XI (a). WASTE DISPOSAL -- CHEMICAL WASTE
A. WHAT IS HAZARDOUS CHEMICAL WASTE? In order to determine proper handling procedures and disposal, a decision must be made regarding whether the chemical waste is hazardous. Federal (EPA 40 CFR 261) and
Laboratory Hazardous Waste Disposal Guidelines
Satellite Accumulation Area (SAA) For safety and environmental reasons, hazardous waste must be stored in a designated "Satellite Accumulation Area." These areas must be inspected weekly for container
Hazardous Waste Procedures. Faculty of Science University of Ottawa
Hazardous Waste Procedures University of Ottawa Contents Hazardous Materials Waste Overview:... 3 Regulations:... 3 General requirements related to packaging waste:... 4 Table 1: List of Appropriate Waste
HAZARDOUS CHEMICAL WASTE DISPOSAL SECTION 7
HAZARDOUS CHEMICAL WASTE DISPOSAL According to Ontario environmental legislation, generators of hazardous waste are responsible for properly packaging and labelling such wastes. The University of Toronto
ST. CLOUD TECHNICAL AND COMMUNITY COLLEGE HAZARDOUS WASTE PROCEDURE
APPLICABILITY This procedure is applicable to all St. Cloud Technical & Community College faculty, staff and students. GENERAL Federal, state and local governments impose strict regulations concerning
Hazardous Waste Management & Waste Minimization Training
Hazardous Waste Management & Waste Minimization Training Environmental Health and Safety Safety Training Building Inspections Accident Investigations Fire Safety Hazardous Materials Management Laboratory
Hazardous Materials Handling and Disposal Policy and Procedures
University of Texas at El Paso Hazardous Materials Handling and Disposal Policy and Procedures The use of hazardous materials is required in numerous work places and educational facilities on the University
TEXAS TECH UNIVERSITY HAZARDOUS WASTE PROGRAM DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY
TEXAS TECH UNIVERSITY HAZARDOUS WASTE PROGRAM DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY 1 TABLE OF CONTENTS I II III IV V VI VII INTRODUCTION CHEMICAL HAZARDOUS WASTE 1. Definition 2. Characteristics
Environmental. and. Health Chemical Safety CHEMICAL WASTE DISPOSAL
U n i v e r s i t y o f C a l i f o r n i a Environmental Health Chemical Safety and Safety Update S a n F r a n c i s c o pub# CSU8 CHEMICAL WASTE DISPOSAL What is chemical waste? A waste is chemical
Chemical Disposal Training
Chemical Disposal Training Cornell University EH&S Revised Feb 2011, Brian S. 1 OBJECTIVE What EH&S wants you to learn today 1. What rules and regulations govern waste management 2. Cornell EH&S s role
14.0 Hazardous Chemical Waste Management
14.0 Hazardous Chemical Waste Management 14.1 Responsibilities. The hazardous waste management program at the UTHSCSA is designed to provide safe, effective and economical disposal of chemical waste generated
5: Types of Hazardous Waste
1. Introduction THE TEXAS A&M UNIVERSITY SYSTEM HEALTH SCIENCE CENTER CHAPTER XI HAZARDOUS WASTE DISPOSAL Hazardous waste disposal is governed by the EPA and the TCEQ through State and Federal regulations.
Hazardous Waste Generator Training
presented by Facilities Management and the office of Hazardous Waste Generator Training Environmental Health & Safety RCRA..."It's The Law!" Hazardous Waste is: Spent material that is: READY TO BE THROWN
The following sections provide hazardous waste safety guidelines and procedures. This section covers the following topics:
13. The following sections provide hazardous waste safety guidelines and procedures. This section covers the following topics: TOPIC PAGE 13.1 Hazardous Waste and Texas State University... 13-2 13.2 Definitions...
Hazardous Waste Compliance Awareness For Faculty and Staff
Hazardous Waste Compliance Awareness For Faculty and Staff Important information for campus employees generating, handling or storing hazardous waste I. Hazardous Waste A. Materials being used for their
PROCEDURES FOR LABORATORY CHEMICAL WASTE DISPOSAL
PROCEDURES FOR LABORATORY CHEMICAL WASTE DISPOSAL In an effort to create a more effective, cost efficient and environmentally friendly waste management system on campus, we are proposing the following
3.2 The Department of Environmental Health and Safety is responsible for;
1 Introduction The have been developed in order to minimize the risk of accidental chemical reactions and exposure resulting from the improper storage of hazardous chemicals. The chemical storage procedures
Laboratory chemical waste disposal guidelines
Laboratory chemical waste disposal guidelines August, 2014 Contents 1. Background... 2 2. How do I arrange disposal of my chemical waste?... 2 3. Information requirements... 2 4. What types of wastes are
Temple College Compliance with the Environmental Protection Agency Requirements
Temple College Compliance with the Environmental Protection Agency Requirements Background: Temple College is subject to the Federal EPA regulations and procedures in regard to chemical usage, safety and
Managing Automotive Repair And Body Shop Wastes
Managing Automotive Repair And Body Shop Wastes For Assistance and More Information Your company may generate other hazardous wastes beyond the examples mentioned within this Booklet. It is your responsibility
INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS
INCOMPATIBILITY OF COMMON LABORATORY CHEMICALS When certain hazardous chemicals are stored or mixed together, violent reactions may occur because the chemicals are unsuitable for mixing, or are incompatible.
UNIVERSITY OF MARYLAND, BALTIMORE COUNTY HAZARDOUS WASTE DISPOSAL GUIDELINES
UNIVERSITY OF MARYLAND, BALTIMORE COUNTY HAZARDOUS WASTE DISPOSAL GUIDELINES I. Introduction The intention of these guidelines is to provide UMBC employees with an understanding of Federal and State hazardous
Managing Auto Repair & Body Shop Wastes
Pima County Department of Environmental Quality Hazardous Waste Generator Program 33 N. Stone Ave., Suite 700, Tucson, Arizona 85701-1429 Managing Auto Repair & Body Shop Wastes Technical Guidance This
F002... The following spent
261.31 Hazardous wastes from non-specific sources. (a) The following solid wastes are listed hazardous wastes from non-specific sources unless they are excluded under 260.20 and 260.22 and listed in appendix
Disposal of chemical waste must be regarded as an integral part of all research projects and teaching programs involving chemical use.
1. Purpose and Objectives This procedure provides information on the generation, collection, storage and disposal of chemical waste to ensure: that the collection, storage and disposal of chemical waste
Berea College Chemical waste/product Management Guide. October 2014
Berea College Chemical waste/product Management Guide October 2014 Chemical Waste Chemical waste is generated in many locations across campus. Chemical waste is generated in laboratories, from painting
HAZARDOUS WASTE MANAGEMENT PROGRAM. For OTTERBEIN UNIVERSITY. Prepared by: 140 North Otterbein Avenue Westerville, Ohio 43081
HAZARDOUS WASTE MANAGEMENT PROGRAM For OTTERBEIN UNIVERSITY Prepared by: 140 North Otterbein Avenue Westerville, Ohio 43081 Otterbein University 0 TABLE OF CONTENTS 1.0 PURPOSE AND SCOPE... 1 2.0 ROLES
Pollution Liability Exposure: Adjustments your automotive business should consider to maintain compliance
: Adjustments your automotive business should consider to maintain compliance Pollution sounds like such a dirty word. And as an automotive service business owner, employee or operator, you might be producing
Chemical Waste Disposal
Chemical Waste Disposal Summary/Purpose: The Chemical Waste Disposal Policy details the minimum requirements and procedures to dispose of Chemicals and Hazardous Waste. Disposal Information and Procedures
Policies and Procedures Manual Waste Management Plan Policy No. 06:04:00 Page 1 of 12
Page 1 of 12 Revision Responsibility: Director of Facility Services and Safety Responsible Executive Officer: Vice President for Financial & Administrative Services Source / Reference: Tennessee Division
Hazardous Waste Training
Hazardous Waste Training Hazardous Waste training is an ANNUAL requirement. Please plan to recertify this training again within one year of today s date if you are still working in an area that may produce
Identifying Your Hazardous Waste
Division of Materials and Waste Management August 2015 Identifying Your Hazardous Waste As a business owner, it is important to know if you generate hazardous waste. Under Ohio EPA s rules, all wastes
When Completed - Fax to (410) 704-2993
Revised 2/12 Date: / / Hazardous Chemical Waste Disposal Request Page of Requestor: Phone #: Email: Department: Building & Room #: Item # Description of Waste Chemicals Quantity Container Size & Type Comments
HAZARDOUS WASTE MANAGEMENT PROGRAM
HAZARDOUS WASTE MANAGEMENT PROGRAM UNIVERSITY RISK MANAGEMENT Occupational Safety and Health Programs 19 Hagood Avenue, Suite 908 Charleston, SC 29425 843-792-3604 Revised: January 2015 TABLE OF CONTENTS
University of California, Santa Barbara Environmental Health and Safety. Hazardous Waste Minimization Plan
University of California, Santa Barbara Environmental Health and Safety Hazardous Waste Minimization Plan 1. Introduction The University of California, Santa Barbara (UCSB) Hazardous Waste Minimization
Hazardous Waste Management Plan
Hazardous Waste Management Plan Introduction The management of hazardous waste is governed by the Environmental Protection Agency (EPA) regulations, specifically, 40CFR260-262. These regulations are the
Chemical Waste Policy Duke University/Medical Center October 10, 2010
Supplement Q Chemical Waste Policy Duke University/Medical Center October 10, 2010 PUBLISHED BY Occupational Environmental Safety Office Environmental Programs Division Phone (919) 684-2794 Fax (919) 684-2422
Waste Minimization Plan
Waste Minimization Plan Revised: April 2011 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton FL 33431 Phone: 561-297-3129 Fax 561-297-2210 Email: [email protected] Web: www.fau.edu/ehs
INSTRUCTIONS FOR THE COLLECTION OF HAZARDOUS WASTE IN BIOCENTER OULU LABORATORIES
INSTRUCTIONS FOR THE COLLECTION OF HAZARDOUS WASTE IN BIOCENTER OULU LABORATORIES All research groups and core facilities in Biocenter Oulu laboratories at Aapistie 5A have a person in charge of hazardous
Hazardous Waste Management Procedures
Hazardous Waste Management Procedures For information and guidance on handling and removal of hazardous waste contact the CSUCI office of Environment, Safety and Risk Management (X 8847). Campus Hazardous
Queen s University Environmental Health & Safety
April 2009 1 SOP-CHEM-01 Introduction The Queen's policy statement on Environmental Management outlines the University s commitment to the protection of the environment through the implementation of an
Safe Storage of Chemicals
Safe Storage of Chemicals Proper storage of chemicals within a laboratory is a difficult and continuing problem. Some experts have stated that the majority of laboratory accidents are related to improper
UNIVERSITY OF KENTUCKY HAZARDOUS WASTE MANAGEMENT TRAINING MANUAL
UNIVERSITY OF KENTUCKY HAZARDOUS WASTE MANAGEMENT TRAINING MANUAL PURPOSE This training material is based on regulations enforced by the US Environmental Protection Agency and Kentucky Division of Waste
Waste Management Program
SUNY Cortland Environmental Health and Safety Office Waste Management Program Inception Date: January 30, 2007 Latest Revision/Review Date October 8, 2015 Previous Revision/Review Date: April 30, 2014
Tufts Environmental Health and Safety April 2010
7. HAZARDOUS WASTE 7.1 Hazardous Chemical Waste The Resource Conservation and Recovery Act (RCRA) of 1976 gave the Environmental Protection Agency the authority to regulate the generation, transportation,
April 2015. Chemical Waste Guide
April 2015 Chemical Waste Guide Guides 1. Obtaining Chemical Waste Disposal Tags 2. Chemical Waste Disposal Tags 3. Lab clean Out Operations 4. Waste Containers 5. Contaminated Debris 6. Ethidium Bromide
Pharmaceutical Waste Program for Inpatient Pharmacy. Portland Service Area Pharmacy Leadership Team
Pharmaceutical Waste Program for Inpatient Pharmacy Portland Service Area Pharmacy Leadership Team What is Pharmaceutical Waste? Pharmaceutical waste is waste generated through IV preparation, compounding,
Proper chemical storage is required to minimize the hazards associated leaks, spills, and accidental mixing of incompatible chemicals.
CHEMICAL STORAGE Proper chemical storage is required to minimize the hazards associated leaks, spills, and accidental mixing of incompatible chemicals. General Storage Guidelines Observe the following
ENVIRONMENTAL HEALTH AND SAFETY HAZARDOUS MATERIALS MANAGEMENT PLAN
ENVIRONMENTAL HEALTH AND SAFETY HAZARDOUS MATERIALS MANAGEMENT PLAN November 2011 University of Northern Colorado Hazardous Materials Management Plan I. General II. III. IV. Responsibilities Definition
7. Chemical Waste Disposal Procedures
7. Chemical Waste Disposal Procedures Substances that Can and Cannot be Disposed of via Sink Drains or in Regular Solid Refuse Containers 1. It is prohibited to pour down a sink or floor drain, or place
SPILLS & SPILL KITS. Spills -General Guidelines:
Spills -General Guidelines: If handled properly, a spill may be nothing more than a nuisance. If handled improperly, a spill can seriously disrupt your activities and the work of your colleagues. At worst,
Guidance Note: Chemical Storage
Department of Environmental Health and Safety Guidance Note: Chemical Storage The proper segregation and storage of chemicals is important in the laboratory because the accidental mixing of incompatible
Any waste solution of 0.1% (e.g. 1mg/ml) or higher is Special Waste (including: unwanted 5mg/ml or 10mg/ml stock solutions).
Ethidium bromide Ethidium Bromide (EtBr), commonly used in research laboratories as a stain for the visualization of nucleic acids in electrophoresis gels, is a toxic chemical and a potent mutagen. When
Managing Hazardous Pharmaceutical Waste
Managing Hazardous Pharmaceutical Waste Environmental Consequences Why the growing concern? Discovery of pharmaceuticals in surface, ground and drinking waters of the U.S. Small concentrations of endocrine
HAZARDOUS WASTE SATELLITE ACCUMULATION MANAGER RESPONSIBILITIES
INTRODUCTION This program applies to Eastern Washington University (EWU) personnel who work with chemicals and generate chemical waste in performance of their job duties. Chemicals may pose a threat to
CHS Medical Group Hazardous Waste Management In Service
CHS Medical Group Hazardous Waste Management In Service Objective Educate staff how to properly manage Regulated Medical Waste (RMW), Chemotherapy Waste and EPA RCRA Hazardous Waste Ensure compliance with
BOSTON COLLEGE ENVIRONMENTAL HEALTH AND SAFETY LABORATORY GUIDE FOR RENOVATIONS, REMODELS, MOVES AND TERMINATIONS
BOSTON COLLEGE ENVIRONMENTAL HEALTH AND SAFETY LABORATORY GUIDE FOR RENOVATIONS, REMODELS, MOVES AND TERMINATIONS I. Policy for Termination of Laboratory Use of Hazardous Materials The Principal Investigator
Waste and Cost Reduction Techniques for Small Parts Cleaners
Waste and Cost Reduction Techniques for Small Parts Cleaners Edited by Ron Still Mechanical components typically need cleaning during repair and maintenance activities, and most maintenance shops use parts
Waste Management Log Book
Waste Management Log Book Web address: www.ehs.psu.edu Designated Accumulation Area: Building & Room Number Location in Room Supervisor: E-mail Individual Assigned to Oversight: E-mail Form 1 Chemical
SUBJECT: Effective Date: Procedure Number: Contractor Environmental Management. 09/03/13 emp11 Procedures
SUBJECT: Effective Date: Procedure Number: Contractor Environmental Management 09/03/13 emp11 Procedures APPLICABILITY/ACCOUNTABILITY: Supersedes: Page Of EMS Procedure-011 1 11 Responsible Authority:
Laboratory Waste Disposal
Laboratory Waste Disposal 1. Purpose This guideline details the procedures to follow in disposing of hazardous waste that is generated in the laboratory in order to minimise risks associated with the disposal
Oxidizer(s) Management and Use Guidelines
Facilities and Campus Services EHS/RMS 3101 Science Circle CPISB Room 102B Anchorage, AK 99508 Oxidizer(s) Management and Use Guidelines This document provides information concerning the handling, storage,
Hazardous Waste Generator Handbook
Hazardous Waste Generator Handbook May 1, 2011 Revised April 16, 2014 A Guide to Complying with Kansas Hazardous Waste Generator Regulations Kansas Department of Health and Environment Division of Environment
ABC CIRCUITS 10 Circuit Drive Circuit Town, IN 12345 SLUG CONTROL PLAN
ABC CIRCUITS 10 Circuit Drive Circuit Town, IN 12345 SLUG CONTROL PLAN The purpose of this plan is to provide detailed instructions for slug prevention and control. A complete copy of this plan is maintained
Newport News Shipbuilding Contractor Environmental, Health and Safety Resource Manual Waste Management
Newport News Shipbuilding Contractor Environmental, Health and Safety Resource Manual Waste Management Newport News Shipbuilding Page 1 WASTE MANAGEMENT 1. Purpose and Scope a. The purpose of this section
Disposal of Pharmaceuticals, and their empty containers, in the Workplace
Disposal of Pharmaceuticals, and their empty containers, in the Workplace Prepared by Bio-Team Mobile LLC There is a lot of misinformation being circulated about disposal of pharmaceuticals ever since
DREXEL UNIVERSITY HAZARDOUS WASTE MANAGEMENT PLAN DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY
DREXEL UNIVERSITY HAZARDOUS WASTE MANAGEMENT PLAN DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY January 2010 Page 1 of 32 HAZARDOUS WASTE MANAGEMENT PLAN TABLE OF CONTENTS Hazardous Waste Management Plan...3
The Texas A&M University System Environmental, Health & Safety Special Thanks to Koch Industries, Wichita, KS
Universal Waste Management Training The Texas A&M University System Environmental, Health & Safety Special Thanks to Koch Industries, Wichita, KS Training Objectives In this training, you will learn: What
FDNY C14 Certificate of Fitness Quiz
FDNY C14 Certificate of Fitness Quiz Name: Date: 1. Who issues a New York City laboratory permit? a) Department of Environmental Protection (DEP) b) Department of Environmental Conservation (DEC) c) Occupational
What is a hazardous drug? Hazardous Drugs: NIOSH. Pharmaceutical Waste: Hazardous pharmaceutical Waste 衛 福 部 疾 病 管 制 署
殘 餘 藥 物 之 處 置 衛 福 部 疾 病 管 制 署 中 區 傳 染 病 防 治 醫 療 網 王 任 賢 指 揮 官 What is a hazardous drug? ASHP 2004 TAB criteria for considering a drug hazardous (adopted by OSHA): 1. Carcinogenicity 2. Teratogenicity 3.
WASTE MANAGEMENT. This document is applicable to all staff and students of the premises of the Department of Medicine.
WASTE MANAGEMENT INTRODUCTION So as to maintain and promote a safe and healthy workplace, efforts should be made to ensure that staff, students and visitors meet government regulations concerning hazardous
HAZARDOUS WASTE DISPOSAL GUIDELINES
HAZARDOUS WASTE DISPOSAL GUIDELINES Purdue University Chemical Management Committee Radiological and Environmental Management Adopted April 1990 Revised October 2013 Table of Contents Table of Contents...
Hazardous Waste Determination and Management Plan
Hazardous Waste Determination and Management Plan Prepared By: Triumvirate Environmental Developed: November 2014 Updated: Program Approval Associate Vice President of Public Safety & Administrative Services
School Of Medicine & Biomedical Sciences. Waste Management Policy
School Of Medicine & Biomedical Sciences. Waste Management Policy Introduction The management and disposal of waste has become highly regulated over the past few years. As a result every employee and student
Household Hazardous Wastes
Household Hazardous Wastes Household Hazardous Wastes (HHW) are products used in your home, workplace and places of leisure and recreation. They can be flammable, corrosive, explosive or toxic, and harmful
HAZARDOUS AND NONHAZARDOUS OIL AND GAS WASTE
RAILROAD COMMISSION OF TEXAS 3 HAZARDOUS AND NONHAZARDOUS OIL AND GAS WASTE OIL AND GAS WASTES The Railroad Commission has jurisdiction over oil and gas wastes, which include all wastes generated in association
Lids, Leaks, Labels and Location All About Satellite Accumulation Martin E. Sánchez Principal Environmental Specialist
Lids, Leaks, Labels and Location All About Satellite Accumulation Martin E. Sánchez Principal Environmental Specialist New Jersey Department of Environmental Protection Hazardous Waste Compliance & Enforcement
Here are some hazardous wastes commonly generated by the marina industry:
Important Note: The following text is excerpted directly from the New York State Department of Environmental Conservation s publication, Environmental Compliance, Pollution Prevention, and Self Assessment
Standard Operating Procedure
Standard Operating Procedure FLAMMABLE LIQUIDS This standard operating procedure (SOP) is intended to provide general guidance on how to safely work with flammable liquids. This SOP is generic in nature
Mechanical Systems Competency 1.20
Competency 1.20 Mechanical systems personnel shall demonstrate a working level knowledge of the safety and health fundamentals of mechanical systems and/or components. 1. Supporting Knowledge and Skills
University of Maryland Baltimore Environmental Health and Safety
University of Maryland Baltimore Environmental Health and Safety The below serves solely as an informative guideline to help researchers and laboratory personnel maintain a safe laboratory environment.