Testing Laboratory of Heat-Tech Center
|
|
|
- Jonas Ferguson
- 10 years ago
- Views:
Transcription
1 Testing Laboratory of Heat-Tech Center Veolia Energy Warsaw, Puławska 2 Street, Warsaw/ Heat-Tech Center, Skorochód-Majewskiego 3 Street, Warsaw GENERAL INFORMATION HTC Testing Laboratory carries out complex tests of preinsulated elements and insulations used for district heating pipelines. Since 2009 the laboratory has been listed as the unit recommended by the association Euroheat & Power for performing tests of the preinsulated pipes. Since 2003, the laboratory is approved by the Polish Centre for Accreditation for the applied test methods. The current scope of accreditation No. AB 414 can be found at website The laboratory is equipped with the unique test stands, designed and constructed by the HTC employees. These are the stands for testing: thermal conductivity coefficient (for the cylindrical insulations and preinsulated pipes) shear strength radial creep soil stress (sandbox and water impermeability) accelerated ageing process - before the thermal conductivity test - before the shear strength test. The laboratory is also equipped with the following measuring devices such as: stereoscopic microscope for determining the average cell size Instron testing machine for compressive and tensile strength tests gas pycnometer for determining the closed cells content in rigid porous materials toothed dial indicator sidle calliper height gauge electronic calipers electronic scales moisture analyzer for determining the sand moisture content. 1 TESTS CARRIED OUT IN HTC TESTING LABORATORY thermal conductivity coefficient λ, W/mK The tests are based on the standards ISO 8497, EN 253 and PB-06 The tests are performed on cylindrical insulations. Thermal conductivity is a fundamental parameter for the thermal properties of the DH insulations. The maximum acceptable value of the thermal conductivity of polyurethane foam used in preinsulated pipes is λ 50 = 0,029 W/mK. thermal conductivity coefficient after ageing λ, W/mK The artificial ageing process precedes the thermal conductivity test. The artificial ageing process is carried out in the heating chamber with the outer casing temperature t = 90 C, much higher than the average ambient temperature of the pipeline operating under the ground t = 8 C. soil stress test of the preinsulated joint assembly The test is based on the standard EN 489 and PB-19 There are two stages: sandbox test and water impermeability test. The main aim of the soil stress test is to check the strength of the joint assembly against the forces influencing the joint during its operation. The sandbox test is to simulate the conditions influencing the preinsulated joints during operation. The water impermeability test is used to evaluate the results of the sandbox test and it is to assess the tightness of the joint by water immersion. radial creep resistance ΔS, % The test is based on the standard EN 253 and PB-18 The test is carried out at 140 C in hours. Its main aim is to check the strength of the preinsulated pipe insulation against long term influence of the constant force. axial and tangential shear strength τ, MPa The test is based on the standard EN 253 and PB-17 The aim of the test is to check the ability of the preinsulated bonded pipe system to withstand the ground reaction force. The minimum acceptable stress value according to EN 253 standard is: τ tan = 0,20 MPa τ ax 23 C = 0,12 MPa τ ax 140 C = 0,08 MPa
2 shear strength test after ageing τ, MPa The test is based on the standard EN 253:2009 and PB-17 The accelerated ageing process is carried out at the service pipe temperature greatly exceeding the actual continuous operating temperature of the PUR foam. The bonded pipe system, which expected life in continuous operating temperature 120 C is 30 years, is tested at t = 160 C in 3600 hours or at t = 170 C in 1450 hours. Tangential or axial shear strength test is done after accelerated ageing process. compressive strength σ, MPa The test is based on the standards EN 253, EN 826, PN-C and PB-20 The test is to determine the compressive strength in radial direction at 10% relative deformation. Minimum compressive strength of PUR foam, used in preinsulated pipelines insulation, is σ 10av = 0,3 MPa. elongation at break A, % The test is based on the standard PN EN 253 and PB-20 The outer casing pipe of the preinsulated system is subjected to the test. The minimal elongation at break of the HDPE casing pipe is A = 350 %. apparent density ρ, kg/m 3 The test is based on the standards EN ISO 845, EN 1602, EN 13470, EN 253 and PB-20 Apparent density is an important parameter of the insulation material endurance. High apparent density provides a proper mechanical strength of the foam as well as shear and creep strength of the preinsulated pipe. The higher is the density of the new insulation, the worse are the thermal insulation properties, because the thermal conductivity coefficient increases. average cell size d, mm The test is based on the standard PN-EN 253 and PB-20 The aim of the test is to determine linear dimension of the insulation cells in radial direction. Average size of PUR foam cell in preinsulated pipes is d av = max 0,5 mm. closed cells content ψ, % The test is based on the standards EN 253, EN ISO 4590 method no 1 and PB-20 The test is carried out with the usage of the gas pycnometer, by measuring the change of the pressure. The corrected closed cells content of the PUR foam is ψ oav = min 88%. voids and bubbles The test is based on the standards EN 253 and PB-20 Voids and bubbles shall not exceed 5% of the cross section area of the insulation. All other individual spaces shall be less than 1/3 of the nominal insulation thickness between steel pipe and casing. water absorption in a high temperature W AV, % The test is based on the standards PN-EN 253 and PB-20 The aim of the test is to check the thermal insulation resistance to damage due to inundation with hot water. The maximum PUR foam water absorption after 90 minute-boiling is WA Vav = max 10%. water absorption by immersion W AV, % The test is based on the standard PN-C and PB-20 The aim of the test is to check the absorbability of thermal insulation material by measuring the buoyancy of the sample immersed in cold water. PUR foam water absorption by immersion after 24 and 168 hours is respectively WA Vav = max 3% and WA Vav = max 4,5 %. center line deviation e, mm The test is based on the standard EN 253 and PB-20 The aim of the test is to check the coaxiality of the casing pipe in the relation to the steel service pipe. The center line deviation means that the insulation thickness in pipe cross section is non-uniform which complicates making a proper joint assembly. preinsulated twin pipe tests The test is based on the standard EN and PB-20 The tests carried out in HTC Laboratory: - end alignment of forward and return service pipes, - distance between forward and return service pipes, - twisting of service pipes, - center line deviation. dimensional stability The test is based on the standard PN-C and PB-20 The aim of the test is to verify whether in rigid porous insulation of foam shells or of the preinsulated pipes, exposed to a certain temperature at certain time, there were no irreversible changes of linear dimensions in each of three mutually perpendicular directions and to determine the degradation temperature of the insulation material. temperature distribution in double-layer insulation The test is based on PB-07 procedure designed by HTC. The aim of the test is to determine the temperature distribution in the cross-section of the insulation, used to verify the thickness of the insulation layers and to check whether the inner layer of the insulation will sufficiently reduce the impact of the heating medium temperature on the outer layer. The test also allows to determine the unit heat losses of the double-layer insulation. 2
3 TEST EQUIPMENT IN HTC LABORATORY 1. Thermal conductivity coefficient test stand Fig. 1 Test stand SB-6 pipe apparatus Test stand so called pipe apparatus (Fig. 1) has been constructed according to standard EN ISO The main elements of the stand: - thermostatic chamber - to keep the constant temperature of the air surrounding the tested sample - testing pipe - to introduce the heat flow into the insulation with assumed temperature and providing zero heat flow in axial directions. recording. The technical construction eliminates the convection effect during the tests. The stand can be used for testing the pipeline insulations: DN20, DN50, DN80 and DN250. The tests can be carried out on the semi-cylindrical and cylindrical insulation shells and on the preinsulated pipes. 2. Axial and tangential shear strength test stand The main elements of the stand (Fig. 2): - testing machine to implement the action of shear forces on the sample - temperature control system - to heat the sample service pipe up to 140 C and maintain this temperature in the permissible deviation limits during initial heating process and during the entire test - computer control system. The value of the force, displacement and speed of the crosshead are recorded. The stand is used for testing the preinsulation pipes with diameters: DN Radial creep resistance test stand The main elements of the stand (Fig. 3): - hydraulic loading system which is responsible for the implementation of continuous loading perpendicular to the axis of the symmetry of the service pipe - temperature control system, which is responsible for heating the service pipe up to the required temperature and maintaining that temperature throughout the test period, hours, recording. Fig. 2 Shear strength test stand Fig. 3 Radial creep resistance test stand 4. Soil stress test stand The main elements of the stand are two modules: "sandbox" and "water tank". We can test the joints made on the preinsulated pipes with diameters up to DN 150. Module sandbox (Fig. 4, 5) consists of the following elements: - rectangular steel structure 1.80 x 1.00 x 1.80 m without a cover - one meter thick sand layer, which covers tested joint assembly - actuator with control system realizing axial forces by moving the sample forward and backward without pause. Setting and counting the number of cycles of movement are provided by the IT software. - temperature control system, which is responsible for heating the steel service pipe during the whole testing time recording 3
4 Module "water tank (Fig. 6) is to performing water impermeability test, and is a horizontal cylindrical steel tank, which realizes of the external pressure effects on the joint assembly by flooding at a constant temperature and constant pressure. Water tank stand is equipped with a temperature and pressure control systems. Fig. 7 Heating chamber for preinsulated pipes ageing before thermal conductivity test Fig. 4, 5 Sandbox Fig. 8 Accelerated ageing process stand before shear strength test NEW EQUIPMENT Fig. 6 Water tank 5. Artificial aging process stand Artificial ageing process before thermal conductivity test (Fig. 7) is carried out in the heating chamber equipped with temperature control system. The chamber is responsible for keeping the complete pipe assembly at an elevated temperature for a certain time. Accelerated aging process before shear strength test (Fig. 8) is carried out on the stand which enables keeping the service pipe at an elevated temperature while the casing is exposed to an ambient temperature. The stand is equipped with temperature control system and continuous data recording system. Fig. 9 Test stand SB-6 plate apparatus Test stand so called plate apparatus heat flow meter apparatus (Fig. 9) has been constructed according to standard EN ISO The tests can be carried out on the plate insulation: 30 mm x 30 mm x t, where t is the thickness of insulation. 4
5 Fig. 10 Heating chamber Exsiccation process before thermal conductivity test (Fig.10) is carried out in the heating chamber equipped with temperature control system. The chamber is responsible for keeping the insulation at an elevated temperature for a certain time. Fig. 11 Climatic chamber Artificial ageing process before thermal conductivity test (Fig. 11) is carried out in the climatic chamber equipped with temperature and humidity control system. OUR CUSTOMERS DH companies: ZEC Łódź, PEC Stargard Szczeciński, PEC Bełchatów, OPEC Puławy, PEC Kutno, GPEC Gdańsk, PEC Suwałki, SYDKRAFT EC Słupsk, Szczecińska Energetyka Cieplna, Energetyka Cieszyńska, Therma Bielsko-Biała, ZEC Katowice, MPEC Chełm, Energoterm Toruń, Vattenfall Polska, PEC Jelenia Góra, Energetyka Cieplna Opolszczyzny, Toruńska Energetyka Cergia SA., PEC Tychy, KPEC Bydgoszcz, SPEC Warszawa, Dalkia Warszawa, OPEC Gdynia, Dalkia Łódź, Dalkia Poznań, Veolia Energia Warszawa, Veolia Czech Republic Preinsulated pipes manufacturers: FINPOL Warszawa, ZPU Jońca Międzyrzecz, STAR-PIPE Poznań, LOGSTOR Polska, PRIM Lublin, ISOPLUS Katowice, Elzas Leszno, ISOPLUS Sondershausen Germany, Logstor Denmark, KVY - Pipe OY Finland Insulation and raw material systems manufacturers: MAT Łódź, ELEKTROTERMEX Ostrołęka, EURICO Ożarów Mazowiecki, HYDROMAT Kobylnica Widziano, Euro Invest Bud Poznań, METALPUR Bydgoszcz, POLYCHEM Poznań, IZOTERM Cząstków Mazowiecki; FOLIMPEX Warszawa, IZOTERMA Przygodzice, MINOVA EKOCHEM S.A. Siemianowice Śląskie, PURINOVA Tarnów/ Bydgoszcz,, MAGWENT Zduńska Wola, BASF Śrem, INTER WW Tuchom, HIT TERM Celestynów, Eutherm Ożarów Mazowiecki, PRODEX Warszawa, KUTE JA EHITUS AS (Tartu, Estonia) Joint assemblies and thermo shrinkable products manufacturers: RADPOL Człuchów, BRUGG Płochocin, PROB Radom, ENERGOFIT Człuchów, CEGA Warszawa, TERMOGUM Warszawa, Kamitech Dzierżoniów, Sarmat-Inżynieria (Minsk, Belarus), CANUSA Canada, HANTECH Sweden, MITTEL Sweden, BERRY PLASTICS Belgium Institutes: Institute of Nuclear Chemistry and Technology Warszawa, Industrial Chemistry Research Institute Warszawa 5
THERMA-TUBE preinsulated pipes and fittings Catalogue of products
THERMA-TUBE preinsulated pipes and fittings Catalogue of products THERMA TUBE preinsulated pipes and fittings TABLE OF CONTENTS 1. GENERAL INFORMATION ABOUT THE USE OF PREINSULATED PIPES AND FITTINGS...
Efficient distribution of district heating and cooling. LOGSTOR pre-insulated pipe technology
Efficient distribution of district heating and cooling LOGSTOR pre-insulated pipe technology LOGSTOR pre-insulated pipe technology LOGSTOR has 50 years of experience in the development, production and
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST Instruction: Check each test method for which you are requesting accreditation. An asterisk beside the NVLAP Test Method Code indicates that proficiency
Master Panel 1000 R5 Roof
Master Panel 1000 R5 Roof Product Description The important feature of the roof elements are the easy installation procedure. The element fix exactly and pushed together without much force. Roof coverage
Master Panel 1000 W Wall
Master Panel 1000 W Wall Product Description In order to generate an aesthethic outlook wall panels are generally produced as micro hedge. Besides, in connection points concealed screw is used which provides
TEXTILE FABRICS AS THERMAL INSULATORS
TEXTILE FABRICS AS THERMAL INSULATORS Zeinab S. Abdel-Rehim 1, M. M. Saad 2, M. El-Shakankery 2 and I. Hanafy 3 1 Mechanical Engineering Department of the National Research Center, Dokki, Giza, Egypt 2
Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes
Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to
UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0
UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0 Prepared By: Patrick L. Paquin, EnergySolutions Date Reviewed By: Mirza I. Baig, EnergySolutions Date Approved By: Thomas F. Dougherty, Columbiana Hi
DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA
DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA DIRECT SHEAR TEST OBJEVTIVES To determine the shear strength parameters for a
Structural fire design Eurocode 5-1.2 Timber structures
Background and Applications Brussels, 18-20 February 2008 Dissemination of information workshop 1 Structural fire design Eurocode 5-1.2 Timber structures Jochen Fornather Austrian Standards Institute [email protected]
Natural Convection. Buoyancy force
Natural Convection In natural convection, the fluid motion occurs by natural means such as buoyancy. Since the fluid velocity associated with natural convection is relatively low, the heat transfer coefficient
European technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
Technical Data. 7. Bearing Fits. 7.1 Interference. 7.2 Calculation of interference F B LLLLLLLLL( A-54
Technical Data 7. Bearing Fits 7.1 Interference For rolling s the rings are fixed on the or in the housing so that slip or movement does not occur between the mated surface during operation or under. This
ElastoFlake & ElastoTec
ElastoFlake & ElastoTec Relining Group 02 Revolutionally injection casting ElastoFlake, a new material from the Relining Group, is a polymer plastic mass intended for injection casting, which was developed
SIGRAFLEX EMAIL. Properties. Applications
Multilayer sealing sheet, adhesive-free made from flexible graphite foil reinforced with stainless steel foils especially for use in PTFE envelope gaskets SIGRAFLEX EMAIL has been developed specially for
Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software
th International Conference on Structural Mechanics in Reactor Technology (SMiRT ) Espoo, Finland, August 9-4, 9 SMiRT -Division 3, Paper 56 Investigations of a Long-Distance MW Heat Transport System with
A PERFORMANCE TEST STUDY ON CHINESE G4 LEAD RUBBER BEARINGS
13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No. 676 A PERFORMANCE TEST STUDY ON CHINESE G4 LEAD RUBBER BEARINGS Demin FENG 1, Cliff CHEN 2, Wenguang LIU
Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction
Module 1 : Conduction Lecture 5 : 1D conduction example problems. 2D conduction Objectives In this class: An example of optimization for insulation thickness is solved. The 1D conduction is considered
The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35
Packaged-Products for Less-Than-Truckload (LTL) Shipment ISTA 3 Series General Simulation Performance Test PROCEDURE VERSION DATE Last TECHNICAL Change: NOVEMBER 2012 Last EDITORIAL Change: JANUARY 2013
ECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
THERMAL INSULATION PROPERTIES OF EXPANDED POLYSTYRENE AS CONSTRUCTION AND INSULATING MATERIALS ABSTRACT
THERMAL INSULATION PROPERTIES OF EXPANDED POLYSTYRENE AS CONSTRUCTION AND INSULATING MATERIALS K. T. Yucel 1, C. Basyigit 2, C. Ozel 3 ABSTRACT Laboratory thermal conductivity testing of insulating materials
The University of Birmingham (Live System)
The University of Birmingham (Live System) Behaviour of Structural Insulated Panels (SIPs) under both short-term and long-term loadings Yang, Jian; Rungthonkit, Prathan Document Version Author final version
The Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, 23 24 February 2011
The Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, 23 24 February 2011 Duncan Wilmot, Technical Manager, Cladtek International, Australia
Thermal conductivity of polyurethane foam - best performance
10th International Symposium on District Heating and Cooling September 3-5, 2006 Tuesday, 5 September 2006 Sektion 6 a Heat distribution pipe properties Thermal conductivity of polyurethane foam - best
Torsion Tests. Subjects of interest
Chapter 10 Torsion Tests Subjects of interest Introduction/Objectives Mechanical properties in torsion Torsional stresses for large plastic strains Type of torsion failures Torsion test vs.tension test
Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied
Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied Stress and strain fracture or engineering point of view: allows to predict the
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP
INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct
Steady Heat Conduction
Steady Heat Conduction In thermodynamics, we considered the amount of heat transfer as a system undergoes a process from one equilibrium state to another. hermodynamics gives no indication of how long
The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.
QUALITY INSIDE When it comes to long life piping for drinking water, sewage, industrial water or gas, there is one name that continues to lead the way - ECOPUR by vonroll. Delivering precision-engineered
TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing
TEST REPORT Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing Report No.: Report Date: 01/28/14 Test Record Retention Date: 12/20/17 130 Derry
INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999
INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS Published: April 1999 CONTENTS 1 Introduction 2 Test Procedures General 3 Standards and Specific Test Procedures
Peltier Application Note
Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you
MASTER DEGREE PROJECT
MASTER DEGREE PROJECT Finite Element Analysis of a Washing Machine Cylinder Thesis in Applied Mechanics one year Master Degree Program Performed : Spring term, 2010 Level Author Supervisor s Examiner :
AISI O1 Cold work tool steel
T OOL STEEL FACTS AISI O1 Cold work tool steel Great Tooling Starts Here! This information is based on our present state of knowledge and is intended to provide general notes on our products and their
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
THERMAL ANALYSIS. Overview
W H I T E P A P E R THERMAL ANALYSIS Overview In this white paper we define and then outline the concept of thermal analysis as it relates to product design. We discuss the principles of conduction, convection,
SURFACE TREATMENT BOND TEST
Test Procedure for SURFACE TREATMENT BOND TEST Effective Date: March 2011 Published: February 2012 1. SCOPE 1.1. This test procedure is used to determine the bond strength characteristics of the interfaces
Figure 2.31. CPT Equipment
Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3
Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.
Lab 3 Tension Test Objectives Concepts Background Experimental Procedure Report Requirements Discussion Objectives Experimentally determine the yield strength, tensile strength, and modules of elasticity
BETONYP building boards. The modern way of living.
BETONYP building boards The modern way of living. Tough for 30 years. Healthy, debarked pine wood and cement: the raw materials used to produce one of our most successful products for more than three decades.
CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests
PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the
Detection of Pipe Leaks Connection of Pulse Monitoring System in Thermal Utilities
ZPU MIĘDZYRZECZ PREINSULATED PIPE Detection of Pipe Leaks in Thermal Utilities Assembly Manual Principles of Assembly and Servicing ZAKŁAD PRODUKCYJNO USŁUGOWY Międzyrzecz Polskie Rury Preizolowane Sp.
Tensile Testing Laboratory
Tensile Testing Laboratory By Stephan Favilla 0723668 ME 354 AC Date of Lab Report Submission: February 11 th 2010 Date of Lab Exercise: January 28 th 2010 1 Executive Summary Tensile tests are fundamental
3 Single-Coated Foam Tapes
3 Single-Coated Foam Tapes Technical Data May, 2008 Product Description 3M Single-Coated Foam Tapes will adhere to a variety of substrates, including latex-painted wood, lacquered wood, enameled steel,
R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
PTFE Slide Bearings 04/10 149
04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,
XI / PHYSICS FLUIDS IN MOTION 11/PA
Viscosity It is the property of a liquid due to which it flows in the form of layers and each layer opposes the motion of its adjacent layer. Cause of viscosity Consider two neighboring liquid layers A
Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.
1 Unit 6: EXTRUSION Introduction: Extrusion is a metal working process in which cross section of metal is reduced by forcing the metal through a die orifice under high pressure. It is used to produce cylindrical
1. Fluids Mechanics and Fluid Properties. 1.1 Objectives of this section. 1.2 Fluids
1. Fluids Mechanics and Fluid Properties What is fluid mechanics? As its name suggests it is the branch of applied mechanics concerned with the statics and dynamics of fluids - both liquids and gases.
Solid shape molding is not desired in injection molding due to following reasons.
PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which
Activity 2.3b Engineering Problem Solving Answer Key
Activity.3b Engineering roblem Solving Answer Key 1. A force of 00 lbs pushes against a rectangular plate that is 1 ft. by ft. Determine the lb lb pressure in and that the plate exerts on the ground due
Solid Mechanics. Stress. What you ll learn: Motivation
Solid Mechanics Stress What you ll learn: What is stress? Why stress is important? What are normal and shear stresses? What is strain? Hooke s law (relationship between stress and strain) Stress strain
European Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
Structural Integrity Analysis
Structural Integrity Analysis 1. STRESS CONCENTRATION Igor Kokcharov 1.1 STRESSES AND CONCENTRATORS 1.1.1 Stress An applied external force F causes inner forces in the carrying structure. Inner forces
Lecture 9, Thermal Notes, 3.054
Lecture 9, Thermal Notes, 3.054 Thermal Properties of Foams Closed cell foams widely used for thermal insulation Only materials with lower conductivity are aerogels (tend to be brittle and weak) and vacuum
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
Technical Notes 3B - Brick Masonry Section Properties May 1993
Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications
Expansion Joint Guide Module 5 - Universal Expansion Joints General - Standard Program (EFB) - Installation Instructions - Technical Data
Expansion Joint Guide Module 5 - Universal Expansion Joints General - Standard Program (EFB) - Installation Instructions - Technical Data BOA Expansion Joints Guide Expansion Joints Guide Summary Module
AN EXPLANATION OF JOINT DIAGRAMS
AN EXPLANATION OF JOINT DIAGRAMS When bolted joints are subjected to external tensile loads, what forces and elastic deformation really exist? The majority of engineers in both the fastener manufacturing
STENCA PIPE. High quality pipe insulation. www.stenca.com
STENCA PIPE High quality pipe insulation WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Heat Transfer Prof. Dr. Aloke Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati
Heat Transfer Prof. Dr. Aloke Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati Module No. # 02 One Dimensional Steady State Heat Transfer Lecture No. # 05 Extended
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
Injection molding equipment
Injection Molding Process Injection molding equipment Classification of injection molding machines 1. The injection molding machine processing ability style clamping force(kn) theoretical injection volume(cm3)
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko
INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer
Chapter Outline. Mechanical Properties of Metals How do metals respond to external loads?
Mechanical Properties of Metals How do metals respond to external loads? Stress and Strain Tension Compression Shear Torsion Elastic deformation Plastic Deformation Yield Strength Tensile Strength Ductility
Battery Thermal Management System Design Modeling
Battery Thermal Management System Design Modeling Gi-Heon Kim, Ph.D Ahmad Pesaran, Ph.D ([email protected]) National Renewable Energy Laboratory, Golden, Colorado, U.S.A. EVS October -8, 8, 006 Yokohama,
Engineering & Testing Services. Hydraulic Fitting Design and Hydro-Mechanical Testing
Engineering & Testing Services Hydraulic Fitting Design and Hydro-Mechanical Testing Aerofit, Inc. APT Laboratory 1425 South Acacia Avenue Fullerton, CA 92831 Main: 714-521-5060 Fax: 714-535-9862 Our Company
CHAPTER 7 DISLOCATIONS AND STRENGTHENING MECHANISMS PROBLEM SOLUTIONS
7-1 CHAPTER 7 DISLOCATIONS AND STRENGTHENING MECHANISMS PROBLEM SOLUTIONS Basic Concepts of Dislocations Characteristics of Dislocations 7.1 The dislocation density is just the total dislocation length
Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?
Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +46 33 22 56 30 Fax: +46 33 13 88 71 [email protected] www.kalibrera.se In May 2011 Elastocon purchased the company Mätcentrum in Eskilstuna,
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
Solution for Homework #1
Solution for Homework #1 Chapter 2: Multiple Choice Questions (2.5, 2.6, 2.8, 2.11) 2.5 Which of the following bond types are classified as primary bonds (more than one)? (a) covalent bonding, (b) hydrogen
Solar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
LOAD-CARRYING CAPACITY OF AXIALLY LOADED RODS GLUED-IN PERPENDICULAR TO THE GRAIN
LOAD-CARRYING CAPACITY OF AXIALLY LOADED RODS GLUED-IN PERPENDICULAR TO TE GRAIN Prof. Dr.-Ing..J. Blaß, Dipl.-Ing. B. Laskewitz Universität Karlsruhe (T), Germany Abstract Glued-in rods have been used
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS Tom Kimerling University of Massachusetts, Amherst MIE 605 Finite Element Analysis Spring 2002 ABSTRACT A FEA transient thermal structural
Cerobear Spindle Bearings for Machine Tool Applications
Cerobear Spindle Bearings for Machine Tool Applications Cerobear Spindle Bearings About CEROBEAR Committed to the abbreviation CEramic in ROlling BEARings, CEROBEAR GmbH is the renowned world leader in
Notes on Polymer Rheology Outline
1 Why is rheology important? Examples of its importance Summary of important variables Description of the flow equations Flow regimes - laminar vs. turbulent - Reynolds number - definition of viscosity
Numerical Simulation of Temperature and Stress Fields in the Rock Heating Experiment
Numerical Simulation of Temperature and Stress Fields in the Rock Heating Experiment Author P. Rálek 1*, M. Hokr 1 1 Technical University of Liberec, Liberec, Czech Republic *Corresponding author: [email protected]
Contents. ELATECH Polyurethane belts 2. ELATECH M and V 3. ELA-flex SD Polyurethane belts 95. Polyurethane belts for conveying applications 125
ELATECH Polyurethane belts 2 Introduction to ELATECH polyurethane belts 2 Page Contents ELATECH M and V 3 Introduction 4 Tension cords 4 Products certifications 4 Mechanical and chemical properties 4 Executions
REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE
REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE A.Rito Proponte, Lda, Lisbon, Portugal J. Appleton A2P Consult, Lda, Lisbon, Portugal ABSTRACT: The Figueira da Foz Bridge includes a 405 m long cable stayed
CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE
CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE 9.1 INTRODUCTION An important reason that composite piles have not gained wide acceptance in the civil engineering practice is the lack of a long
Free piston Stirling engine for rural development
Free piston Stirling engine for rural development R. Krasensky, Intern, Stirling development, [email protected] W. Rijssenbeek, Managing director, [email protected] Abstract: This paper presents
Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less
Packaged-Products for Parcel Delivery System Shipment 70 kg (150 lb) or Less 3A2 008 ISTA 3 Series General Simulation Performance Procedure VERSION DATE Last TECHNICAL Change: FEBRUARY 2008 Last EDITORIAL
Effect of design parameters on temperature rise of windings of dry type electrical transformer
Effect of design parameters on temperature rise of windings of dry type electrical transformer Vikas Kumar a, *, T. Vijay Kumar b, K.B. Dora c a Centre for Development of Advanced Computing, Pune University
Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests
Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages
Drained and Undrained Conditions. Undrained and Drained Shear Strength
Drained and Undrained Conditions Undrained and Drained Shear Strength Lecture No. October, 00 Drained condition occurs when there is no change in pore water pressure due to external loading. In a drained
Seamless stainless tubes for hydraulic and instrumentation systems
Seamless stainless tubes for hydraulic and instrumentation systems stock assortment integrated production technical knowledge network of sales and service Reduce your lifecycle costs When selecting tubes
TECHNICAL DATA SHEET GRILON BG-15 S
TECHNICAL DATA SHEET GRILON BG-1 S Grilon BG-1 S is a heat stabilised PA6 injection moulding grade with 1% glass fibres. Grilon BG-1 S has the following important properties: Excellent surface finish Easy
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Stress Strain Relationships
Stress Strain Relationships Tensile Testing One basic ingredient in the study of the mechanics of deformable bodies is the resistive properties of materials. These properties relate the stresses to the
Prestressed Concrete Pipe Fitness for Service and Repair
Prestressed Concrete Pipe Fitness for Service and Repair Rasko Ojdrovic [email protected] 781-907-9231 IAEA - EPRI 15 October 2014 www.sgh.com SGH Pipeline Experience More than 25 years of research, analysis,
THERMAL INSULATION ISOCOMPACT
THERMAL INSULATION ISOCOMPACT isocompact CLOSEDCELL, CROSSLINKED POLYOLEFIN FOAM TROCELLEN is a closecell and crosslinked polyolefin foam for insulation (polyolefins include PE, PP, copolymers, EVA etc.),
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043
METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING
METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING Met E 206 MATERIALS LABORATORY EXPERIMENT 1 Prof. Dr. Rıza GÜRBÜZ Res. Assist. Gül ÇEVİK (Room: B-306) INTRODUCTION TENSION TEST Mechanical testing