XBee Wireless Blood Pressure Monitoring System with Microsoft Visual Studio Computer Interfacing
|
|
|
- Tyrone Harper
- 10 years ago
- Views:
Transcription
1 2015 6th International Conference on Intelligent Systems, Modelling and Simulation XBee Wireless Blood Pressure Monitoring System with Microsoft Visual Studio Computer Interfacing Tonny Heng Yew Ling University College of Technology Sarawak Lim Jin Wong Laila Taib College Sibu.Malaysia Jocelyn Ee Hung Tan Laila Taib College Chong Kee Lee University College of Technology Sarawak Abstract - In this modem age, everything comes with wireless, portability and ease to use. Technological developments of wireless devices and systems can also be found in medical field. This has allowed physicians and healthcare providers to connect remotely with patients and give a proper care. Wireless technology in medical field has become readily apparent. E-health and m-health (using mobile devices) provide the most effective patient care and medicine dosage. Human prefer an easy way to use the medical device without any medical knowledge. This paper proposes a blood pressure monitoring device with wireless system which links to computer and records the reading automatically. So, an automated blood pressure measuring device will be used in this project and XBee is chosen to the blood pressure measuring device wirelessly to the computer. Two XBee will be used in this project, one is to transmit and another one is to receive the data. Each XBee will be connected to a microcontroller buildin PIC to process the reading obtained from the blood pressure measuring device. The received blood pressure reading will be recorded. An interfacing system which is created by using Visual Basic will record the reading into a database and show the result to the users. Keywords: Blood pressure; XBee I. INTRODUCTION Blood pressure refers to the pressure of the blood in arteries. Blood pressure happens when heart pumps blood around the body through the arteries, by contracting and relaxing [1]. So it is a measure of how forcefully of the heart pumping blood around our body [2]. Each measurement of blood pressure will always give two numbers, for example 120/80 mmhg. The first (higher) number is called the systolic blood pressure and the second (lower) number is the diastolic blood pressure. So the 120 means systolic blood pressure (higher number) and 80 for diastolic blood pressure (lower number). The blood pressure is measured in millimeters of mercury (mmhg) [3]. The most common technique for monitoring the blood pressure is using the stethoscope in classic way by most of the doctors in medical environment. Recently, a lot of medical equipments have stepped into the high technology world. So, easier way to monitor blood pressure has been published. Nowadays, several companies come out with digital blood pressure monitoring devices, which will automatically measure the blood pressure without any knowledge of how to measure blood pressure. Users just need to follow the instruction provided with the device. The automated blood pressure monitoring device solves a lot of problems that most doctor face, such as white coat effect. Doctors can now differentiate white coat hypertension from essential hypertension by using blood pressure monitoring systems [4]. Users also can measure their blood pressures anytime, at home or workplace. Along with the evolution of technology, the data of blood pressure measured can be recorded and put into the computer to analyze. One of the problem of the latest blood pressure devices which can be found in medical area is when the patient has white-coateffect. This will result in fault and inaccuracy of blood pressure reading from high-risk patients and pregnancy. As the latest blood pressure devices need cable connection to computer in order to send the data and record in the computer automatically, the main concept of this project is to cancel out the cable connection between the computer and blood pressure sensor by using the XBee. The data will be recorded in the computer with graphical user interface to let the patients easily seem their blood pressure readings and when the time when blood pressure is taken. II. LITERATURE REVIEW A. Blood Pressure From the paper research and online information, the average blood pressure reading for a healthy person is 115/75 mmhg, which are 120/80 mmhg and 105/65 mmhg during day time (awake) and night time (asleep) respectively. For the hypertension threshold, the average blood pressure reading is 130/80 mmhg, around 135/85 mmhg while awake and 120/75 mmhg while sleeping. At night time (sleeping) average systolic and diastolic blood pressure should both be at least 10% lower than day time (awake) average [5]. High blood pressure does not only occur for hypertension threshold, but it may also occur depends on emotions, /15 $ IEEE DOI /ISMS
2 exercise, talking, using tobacco and caffeine products [6]. There are several reasons that cause the hypertension of a patient and give a fault or inaccurate blood pressure reading. So white coat effect is discovered and it can cause a patient to overtreatment. This is both real and common in the management of hypertension. Researchers and doctors found out that blood pressure reading in medical environment or doctors offices were consistently higher than the blood pressure reading taken in home [7]. Patients with white coat hypertension may respond differently to antihypertensive drugs and having more side effects. According to a paper written by O Brien E, most of the white coat effect founders based on the Ambulatory Blood Pressure Monitoring (ABPM) system to find out that some patients might show more tension. This situation will cause the blood pressure to become high which is hypertension, but actually the patients have normal blood pressure. During daytime and night-time period, blood pressure measurement at home is devoid of the white coat effect [8]. It is important to acquire an accurate blood pressure reading allowing physician to make efficient treatment to patient especially pregnant woman. A correct blood pressure reading enables the doctor to give efficient drug treatment to the patient and pregnant woman especially for pregnant woman who have high blood pressure, which is called pregnancy-induced hypertension or gestational hypertension. This phenomenon will influence the blood pressure reading. With the correct reading of blood pressure and knowledge of the condition of pregnant woman, doctor will check whether the medicines taken to lower blood pressure are still safe or not, by considering the risks of pregnant woman and baby very carefully [9]. B. Types of Blood Pressure Measuring There are two ways to measure blood pressure, namely classical type which uses stethoscope and automated type which uses high technology. The classical type of measuring blood pressure is quite complicated when compared to automated type. The classic type requires the cuff to be placed around the upper arm at same height as the heart and inflated with the bulb until the cuff is filled with air. This may cause the patient to feel uncomfortable and the artery will close. Doctor will then use the stethoscope to listen to the Korotkoff sound and slowly release the air in the cuff. Systolic blood pressure is the first Korotkoff sound produced when the pressure of cuff is same as the pressure produced by heart. As the air in the cuff is further released, the sound will become quieter and quieter, until the cuff stops limiting blood flow and to allow smooth flow of blood. This silent Korotkoff sound will be diastolic blood pressure. For the automate type blood pressure measuring, the patient just only need to wear the cuff at same height as the heart. The cuff is connected to a device. The device will inflate the cuff to a certain level when the ON/OFF button is pressed. Then it will deflate automatically. At the same time it deflates, the sensor in the device will detect the pulse and pressure of blood in artery and the information will show on display screen [10]. C. Monitoring of Blood Pressure According to a paper written by, Michel Burnie and Guido Grassi, both ambulatory blood pressure and home blood pressure monitoring provide more reliable and reproducible information on blood pressure. The blood pressure values obtain by Home Blood Pressure Monitoring appears to be more closely related to target organ damage. So measurement of out-of-office blood pressure is recommended. According to a paper with title European Society of Hypertension Practice Guidelines for home blood pressure, home blood pressure monitoring (HBPM) is a valuable tool in the daily management for hypertension patients and pregnant woman. It also shows that HBPM should be performed daily at least 3 and preferably 7 days before visiting the doctor. Duplicated measurements should be obtained in the morning (before drug intake if treated) and in the evening (before eating), with two measurements per occasion (1 2 min apart). Blood pressure values measured on the first monitoring day should be discarded. HBPM helps to improve compliance with long term treatment, hypertension control rates and conditions where strict blood pressure control is mandatory (high-risk patients and pregnant woman). It s also important for the physician to know the daily blood pressure of a patient in order to make an efficient treatment and decrease the unnecessary drug intake for the patient which may lead to side-effect. Daily blood pressure reading also serves as a further reference for physician and enables physician to whether there is any improvement on the patient s condition or not. There have several types of blood pressure devices such as ambulatory measurement of blood pressure and selfmeasurement of blood pressure which is also called home blood pressure measurement. Ambulatory blood pressure (ABP) monitoring will measure the patient s blood pressure at every minutes over 1 day. The patient can undergo normal activities, including sleeping. This method of measuring blood pressure can only be used for the person in certain circumstances such as pregnant women and elders. Then the result of blood pressure reading over one day will be given to the physician for further analysis. It can be used to get an accurate reading on the patient [11]. Selfmeasurement of blood pressure, also called home blood pressure monitoring is portable and it is easy to use by everyone. It uses oscillometric method to obtain the blood pressure. The cuff is worn on the upper arms of the patient and the position need to be at the same level as the hearts. START button is push and the cuff will inflate and deflate automatically. Then the reading can be read on the display or the reading will be sent to the computer through the connection from blood pressure monitoring device to computer. 6
3 D. Sensor and Ways to Get Blood Pressure Reading Nowadays, blood pressure device also uses latest technology to measure our blood pressure by using the builtin pressure sensor. Different blood pressure devices use different pressure sensors. Most of the pressure sensors use Microelectromechanical systems (MEMS) purposely invented to be a small size and has low power consumption. MEMS means micro-electro-mechanical-system; it is the technology of very small devices that are made using the techniques of microfabrication. A lot of sensors have implemented MEMS technology into the design as it is small and light-weight [12]. Oscillometric method uses an electronic pressure sensor with a numerical readout of blood pressure. In most cases, the cuff is inflated and released by an electrically operated pump and valve, which may be fitted on the wrist (elevated to heart height), although the upper arm is preferred. Initially the cuff is inflated to a pressure in excess of the systolic arterial pressure, and then the pressure is reduced to below diastolic pressure. Once the blood flow is present, but restricted, the cuff pressure will vary periodically in synchrony with the cyclic expansion and contraction of the brachial artery. The values of systolic and diastolic pressures are computed from the raw data, using an algorithm. E. Analysis of the Bluetooth Technology Nowadays, there are different types of wireless communication. Bluetooth is one of the common ways used in a lot of electronic gadgets such as laptop, mobile phone, mouse and keyboard. Bluetooth is a wireless technology with global standard for expanding range of devices and services. It was invented by telecom vendor Ericsson in Bluetooth also uses unlicensed radio transmission to transmit and receive data in the speed of 2.4GHz to 2.485GHz. Bluetooth is mainly developed to be used in personal area network (PAN). PAN is defined as a network of devices in the range of a person which can communicate with each other [13]. Piconet and Scatternet are two different topologies through Bluetooth communication occurs. Piconet has only 8 nodes (devices) connected where one is master and one or more than one are slave devices. Scatternet forms when multiple piconets overlap [14]. F. XBee Technology XBee is a specification for a suite of high level communication protocols. It is created for control and sensor networks based on the IEEE standard. It is created by the ZigBee Alliance which runs in low data rate with low power consumption and small packet devices. It is a transceiver, which means it can transmit data wirelessly and it can also receive data wirelessly. XBee is intended to be simpler and low cost because low cost allows the technology to be widely used in wireless control and sensor networks. XBee is Series 1 ( ), comes with the firmware to create connection for point to point or star network. ZigBee devices have three types: ZigBee Coordinator, ZigBee Router and ZigBee End Device [15]. G. WiFi Technology WiFi has become a dominant standard for WLAN (wireless LAN). It is mainly developed to operate as a wireless Ethernet. WiFi is an open-standard technology which allows the wireless connectivity between equipment and local area networks [16]. It runs in unlicensed radio spectrums. WiFi can be set as open access to allow public to connect to it. The range of the WiFi is about 50 to 150 meters. The encryptions of the WiFi are WEP based on IEEE and WPA based on IEEE i. Nowadays, those two encryptions can be hacked easily so it is not recommended to be used in personal area network [17]. TABLE I. Data rate COMPARISON OF XBEE, BLUETOOTH AND WIFI XBee Bluetooth WiFi 20, 40, and 250 Kbits/second 1 Mbits/second 11 & 54Mbits/second Range meters 10 meters meters Frequency band Power Consumption Max number of cell nodes 868/915 MHz, 2.4GHz 2.4GHz 2.4GHz, 5GHz Very Low Medium High More than H. X-CTU X-CTU is a free multi-platform application designed to enable developers to interact with Digi RF (radio frequency) modules through a simple-to-use graphical interface. It includes new tools that make it easy to set up, configure and test XBee RF modules. XCTU includes all of the tools a developer needs to quickly get up and running with XBee. Unique features like graphical network view, which graphically represents the XBee network along with the signal strength of each connection, and the XBee API frame builder, which intuitively helps to build and interpret API frames for XBees being used in API mode, combine to make development on the XBee platform easier than ever. I. Visual Studio Microsoft Visual Studio is an Integrated Development Environment (IDE) developed by Microsoft. It is used to develop computer programs for Microsoft Windows, as well as web sites, web applications and web services. Visual Studio uses Microsoft software development platforms such as Windows API, Windows Forms, Windows Presentation Foundation, Windows Store and Microsoft Silverlight. It can produce both native code and managed code. 7
4 Visual Studio includes a code editor supporting IntelliSense as well as code refactoring. The integrated debugger works both as a source-level debugger and a machine-level debugger. Other built-in tools include a forms designer for building GUI applications, web designer, class designer, and database schema designer. It accepts plug-ins that enhance the functionality at almost every level, including adding support for source-control systems (like Subversion) and adding new toolsets like editors and visual designers for domain-specific languages or toolsets for other aspects of the software development lifecycle (like the Team Foundation Server client: Team Explorer). Visual Studio supports different programming languages and allows the code editor and debugger to support (to varying degrees) nearly any programming language, provided a language-specific service exists. Built-in languages include C [18], C++ and C++/CLI (via Visual C++), VB.NET (via Visual Basic.NET), C# (via Visual C#), and F# (as of Visual Studio 2010[19]). received from the XBee into the computer. Normally blood pressure device can only store up to certain limit of readings because the memory of the device is limited. Computer has large memory if compared to the blood pressure device, so it can store a lot of readings and perform calculation of the average blood pressure of a user. Visual Studio 2014 will be used to create a computer interface that can record the data and create a table of blood pressure reading. It also will arrange the readings by time and plot a graph for the user and physician to recognize easily. Before the use of XBee, it needs to be configured by using the X-CTU program. X-CTU is used to update or change the firmware on the radios. X-CTU can switch XBee radio from router to coordinator or switch between API and AT modes. FTDI drivers will be installed to let the computer talks via serial to the XBee module board. III. METHODOLOGY The reading from the blood pressure device needs to be taken out and sent to the computer via XBee. The most complicated part is to get the reading from the blood pressure device. Further investigation of the blood pressure device is needed in order to find the reading data store. Figure 2. Coordinator XBee Function. Figure 1. Block Diagram of the Concept. Figure 1 shows how the wireless blood pressure monitoring system with computer interfacing works. Arduino Uno will be the main part of getting the blood pressure reading from the device. The data point in the blood pressure device will be connected with the Arduino Uno analog input. The IC chip will be programmed with a code that sends the input data from analog port via XBee to another XBee that is connected with a computer. Visual Studio will be used to write a program to record the data Figure 3. End Device XBee Function. 8
5 Two XBees are needed to run as the wireless protocol sends the blood pressure reading obtained by Arduino to the computer. In order to use those two XBees, it is required to programme one of the XBees into a coordinator device and another as the end device. In figure 2, the first XBee is configured as coordinator and XBee in figure 3 is configured as end device. Those two XBees need to have same PAN ID in order to send and receive data in the same ID. SL and SH are Serial Number Low and Serial Number High respectively. Those serial numbers had been configured and programmed inside the XBee chip by the factory. SL and SH are used to set the DH and DL, which is Destination Address High and Destination Address Low respectively. From figure 2 and 3, the two XBees were configured with the destination address of each other. The XBee will send the data to the DH and DL set and receive the data from there. The code that is written in Visual Studio will detect the virtual serial port which is made by FTDI driver to receive the data. IV. CONCLUSION Wireless blood pressure monitoring system will bring advantages to physician, which allows physician to record the data automatically. Wireless blood pressure monitoring system is also more portable without the wire connection to the computer. Graphical user-interface helps user to recognize their blood pressure easily. An application that can install in IOS and Android system will be written for the user to synchronize to their blood pressure reading recorded in the computer. This type of the blood pressure is strongly suggested for home use. V. FUTURE IMPROVEMENT It is very inconvenient for the patients to visit and show their blood pressure report to their physician. In order to solve the problem, a user friendly interface can be developed to allow patients to contact their physician directly, conclude their blood pressure readings and send those readings to the physician. There are a lot of blood pressure devices in hospital but doctor needs to go around and monitor each patient s blood pressure. In the future, a program can be developed to recognize different blood pressure reading from different blood pressure monitoring devices used in hospital or large medical area. Furthermore, an IOS or Android application can also be developed to allow user to gain access to their blood pressure reading anytime and anywhere. REFERENCES [1] British Heart Foundation 2013, Blood Pressure, p.8. [2] Parkinson s UK, Low blood pressure and Parkinson s, September 2014, p.1. [3] UMHS Clinical Care Guidelines, Home Blood Pressure Monitoring, University of Michigan Hospitals and Health Centers, April 2014, p.2. [4] Inga Harris, Blood Pressure Monitors, University of Strathclyde, 2008, p.1. [5] McGrath BP. Ambulatory blood pressure monitoring. Med J Australia 2002;176: [6] UMHS Clinical Care Guidelines, Home Blood Pressure Monitoring, University of Michigan Hospitals and Health Centers, April 2014, p.3. [7] Salynn Boyles, White Coat Effect Linked to Hypertension Overtreatment, 10 June [8] O Brien E, The value of 24-h blood pressure monitoring to assess the efficacy of antihypertensive drug treatment. Hot Topics Hypertension 2011;4(12):7-23. [9] British Heart Foundation, Blood Pressure, Registered Charity No at England [10] Matt Soniak, How Do Blood Pressure Tests Work, And What Do Those Numbers Mean, November [11] Siti Atikah Binti Mohamad Basar, An Automated Non-Intrusive Blood Pressure (NIBP) As Assisted Device for Cardiac Monitoring System, Universiti Teknologi Malaysia, 2013, 2:9-10. [12] Aysran Zyrati Binti Yahya, Portable Detection Device for Patients with Sleep Apnea, Universiti Teknologi Malaysia, 2013, 2: [13] Malik Zaka Ullah, An Analysis Of The Bluetooth Technology, School of Computing Blekinge Institute of Technology, Sweden, June 2009, p.6. [14] Malik Zaka Ullah, An Analysis Of The Bluetooth Technology, School of Computing Blekinge Institute of Technology, Sweden, June 2009, pp [15] P.Rohitha, P.Ranjeet Kumar, Prof.N.Adinarayana, Prof.T.Venkat Narayana Rao, Wireless Networking Through ZigBee Technology, July 2012;2(7):1. [16] Technology Tracking, WiFi Technology, July, 2003, pp.1-4. [17] John Donovan, Security Issues with Wi-Fi, Bluetooth, and ZigBee, Convergence Promotions LLC, May [18] Brenner, Pat, C99 library support in Visual Studio Visual C++ Team Blog. Microsoft. Retrieved 3 August [19] Andrew Kennedy, Don Syme, Kenji Takeda, F# at Microsoft Research, Microsoft Research, Cambridge. 9
Building a Basic Communication Network using XBee DigiMesh. Keywords: XBee, Networking, Zigbee, Digimesh, Mesh, Python, Smart Home
Building a Basic Communication Network using XBee DigiMesh Jennifer Byford April 5, 2013 Keywords: XBee, Networking, Zigbee, Digimesh, Mesh, Python, Smart Home Abstract: Using Digi International s in-house
Using Xbee 802.15.4 in Serial Communication
Using Xbee 802.15.4 in Serial Communication Jason Grimes April 2, 2010 Abstract Instances where wireless serial communication is required to connect devices, Xbee RF modules are effective in linking Universal
ZIGBEE 802.15.4. ECGR-6185 Advanced Embedded Systems. Charlotte. University of North Carolina-Charlotte. Chaitanya Misal Vamsee Krishna
ECGR-6185 Advanced Embedded Systems ZIGBEE 802.15.4 University of North Carolina-Charlotte Charlotte Chaitanya Misal Vamsee Krishna WPAN A personal area network (PAN) is a computer network used for communication
Affordable ABPM and strictly guideline-based SBPM for accurate out-of-office blood pressure measurement.
Affordable ABPM and strictly guideline-based SBPM for accurate out-of-office blood pressure measurement. Instruction Manual EN 3 a EN The Microlife WatchBP O3 (Out Of Office) is designed to provide reliable
Short-range Low Power Wireless Devices and Internet of Things (IoT)
Short-range Low Power Wireless Devices and Internet of Things (IoT) Mats Andersson, CTO, connectblue Phone: +46 40 630 71 00 Email: [email protected] Web: www.connectblue.com Version 1.1 February
This idea could limit unnecessary visits and help developing countries to provide healthcare remotely as well.
I. The Healthcare Problem a. Explanation of why this solution is needed. b. How we can solve the problem. c. The components needed to solve the problem. II. Bluetooth Enabled Medical Device Architecture
Measurement of Blood Pressure
Measurement of Blood Pressure Ambulatory and Home Blood Pressure Monitoring BHS Non Medical Prescribing Update MSc. Management of Hypertension in Primary Care University of Birmingham February 2013 Louise
ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE
ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE S.Josephine Selvarani ECE Department, Karunya University, Coimbatore. Abstract - An on-line health monitoring of physiological signals of humans such as temperature
WISE-4000 Series. WISE IoT Wireless I/O Modules
WISE-4000 Series WISE IoT Wireless I/O Modules Bring Everything into World of the IoT WISE IoT Ethernet I/O Architecture Public Cloud App Big Data New WISE DNA Data Center Smart Configure File-based Cloud
A Wireless Sensor Network for Weather and Disaster Alarm Systems
2011 International Conference on Information and Electronics Engineering IPCSIT vol.6 (2011) (2011) IACSIT Press, Singapore A Wireless Sensor Network for Weather and Disaster Alarm Systems Cholatip Yawut
Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2
Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2 1 PG Student (M. Tech), Dept. of ECE, Chirala Engineering College, Chirala., A.P, India. 2 Assistant Professor, Dept.
Intelligent Home Automation and Security System
Intelligent Home Automation and Security System Ms. Radhamani N Department of Electronics and communication, VVIET, Mysore, India ABSTRACT: In todays scenario safer home security is required, As the technology
Figure 1.Block diagram of inventory management system using Proximity sensors.
Volume 1, Special Issue, March 2015 Impact Factor: 1036, Science Central Value: 2654 Inventory Management System Using Proximity ensors 1)Jyoti KMuluk 2)Pallavi H Shinde3) Shashank VShinde 4)Prof VRYadav
Design of Remote data acquisition system based on Internet of Things
, pp.32-36 http://dx.doi.org/10.14257/astl.214.79.07 Design of Remote data acquisition system based on Internet of Things NIU Ling Zhou Kou Normal University, Zhoukou 466001,China; [email protected]
Surveillance System Using Wireless Sensor Networks
Surveillance System Using Wireless Sensor Networks Dan Nguyen, Leo Chang Computer Engineering, Santa Clara University Santa Clara, California, USA [email protected] [email protected] Abstract The
Measuring Your Blood Pressure at Home. A Review of the Research for Adults
Measuring Your Blood Pressure at Home A Review of the Research for Adults Is This Information Right for Me? Yes, if: A doctor* has told you that you may have high blood pressure, also called hypertension.
Process Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
Implementation of Cloud-Computing Healthcare based on Xenon Uploading System and Hilbert Huang Transform
Implementation of Cloud-Computing Healthcare based on Xenon Uploading System and Hilbert Huang Transform Terry B J Kuo 1,2,3, Yu-Cheng Lin 1,2, I-Te Hsieh 1,2, Cheryl C H Yang 1,2,3, Kuan-Liang Kuo 4,
Design of Wireless Home automation and security system using PIC Microcontroller
IJCAES ISSN: 2231-4946 Volume III, Special Issue, August 2013 International Journal of Computer Applications in Engineering Sciences Special Issue on National Conference on Information and Communication
Professur Technische Informatik Prof. Dr. Wolfram Hardt. Network Standards. and Technologies for Wireless Sensor Networks. Karsten Knuth 16.07.
Network Standards and Technologies for Wireless Sensor Networks Karsten Knuth 16.07.2008 Index 1. Motivation 2. Introduction 3. Bluetooth 4. ZigBee 5. nanonet 6. Roundup 16.07.2008 Network Standards 2
Demystifying Wireless for Real-World Measurement Applications
Proceedings of the IMAC-XXVIII February 1 4, 2010, Jacksonville, Florida USA 2010 Society for Experimental Mechanics Inc. Demystifying Wireless for Real-World Measurement Applications Kurt Veggeberg, Business,
Bluetooth wireless technology basics
Bluetooth wireless technology basics Abstract... 2 Introduction... 2 How Bluetooth wireless technology works... 3 BWT network topologies... 4 BWT security... 5 Establishing BWT connections... 6 Activating
Android based Secured Vehicle Key Finder System
International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Android based Secured Vehicle Key Finder System Sindhoori S. 1, Dr. N. Sathish Kumar 2 *(M.E. Embedded System Technologies, Sri
Intelligent Street lighting management using ZigBee. Martin SCHULTE-HOBEIN Field Application Engineer, EMEA Digi International Email: msh@digi.
Intelligent Street lighting management using ZigBee Martin SCHULTE-HOBEIN Field Application Engineer, EMEA Digi International Email: [email protected] Agenda Digi Overview What is ZigBee? Typical M2M Scenario
WI-FI VS. BLUETOOTH TWO OUTSTANDING RADIO TECHNOLOGIES FOR DEDICATED PAYMENT APPLICATION
WI-FI VS. BLUETOOTH TWO OUTSTANDING RADIO TECHNOLOGIES FOR DEDICATED PAYMENT APPLICATION Ingenico is often asked: what are the differences between Bluetooth and Wi-Fi technologies, which is the best one,
Tecnologías Inalámbricas.
Tecnologías Inalámbricas. Why is Wireless Security Different? There are four major differences for wireless services: Bandwidth Allowable error rates Latency Power Constraints Secure Mobile Devices Characteristics
Wireless Personal Area Networks (WPANs)
Wireless Personal Area Networks (WPANs) Bluetooth, ZigBee Contents Introduction to the IEEE 802 specification family Concept of ISM frequency band Comparison between different wireless technologies ( and
EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit
EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit EDK 350 User Manual Important Notes This information describes the type of component and shall not be considered as assured characteristics. No
Wireless LANs vs. Wireless WANs
White Paper Wireless LANs vs. Wireless WANs White Paper 2130273 Revision 1.0 Date 2002 November 18 Subject Supported Products Comparing Wireless LANs and Wireless WANs Wireless data cards and modules,
Smart Home System Using Android Application
Smart Home System Using Android Application Karlapudi Siva Krishna Mr. Md Mohiddin Dr. M. Narendra Kumar, Dr. S. Sreenatha Reddy Student (M. Tech) Embedded Sys Asst. Prof, ECE Prof & Vice-Principal Prof
INFORMATION TECHNOLOGY MANAGEMENT COMMITTEE LIVINGSTON, NJ WWW.LIVINGSTONNJ.ORG ITMC TECH TIP ROB COONCE, MARCH 2008
INFORMATION TECHNOLOGY MANAGEMENT COMMITTEE LIVINGSTON, NJ WWW.LIVINGSTONNJ.ORG What is wireless technology? ITMC TECH TIP ROB COONCE, MARCH 2008 In our world today, this may mean sitting down at a coffee
Electrocardiogram (ECG) Monitoring System using Bluetooth technology
Electrocardiogram (ECG) Monitoring System using Bluetooth technology Zarina Md Amin, Suryani Ilias, Zunuwanas Mohamad Department of Electrical Engineering, Polytechnic of Sultan Abdul Salahuddin Abdul
Microchip Technology. February 2008 Valerio Moretto Slide 1
Microchip Technology February 2008 Valerio Moretto Slide 1 Connectivity Solutions Wired Wireless February 2008 Valerio Moretto Slide 2 Microchip Solutions More complex software Operating Systems >40 MIPS
Vasc Health Risk Manag. 2011; 7: 709 717. Published online 2011 November 30. doi: 10.2147/VHRM.S27193 PMCID: PMC3237100
Vasc Health Risk Manag. 2011; 7: 709 717. Published online 2011 November 30. doi: 10.2147/VHRM.S27193 PMCID: PMC3237100 Validation of four automatic devices for self-measurement of blood pressure according
Wireless 802.11g CF Card User Manual
Wireless 802.11g CF Card User Manual Version 1.0 Copyright statement No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, whether electronic,
Remote Monitoring and Control System for DC Motor using Zigbee Protocol
Remote Monitoring and Control System for DC Motor using Zigbee Protocol Mohini Reddy 1, Vidya Sawant 2 1 M.Tech Student,Electronics Engineering Department, Mukesh Patel School of Technology & Management,
Bluetooth Health Device Profile and the IEEE 11073 Medical Device Frame Work
Bluetooth Health Device Profile and the IEEE 11073 Medical Device Frame Work Rudi Latuske, ARS Software GmbH 1. Bluetooth in Medical Applications Bluetooth, as a short range wireless technology, is very
AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE
C A R D I O P E R F E C T AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE UNDERSTANDING ERROR CODES ERROR CODE DESCRIPTION 1 Unknown error 2 This can indicate one of the following problems: After
Setting Up the ZigBee Ethernet Gateway
Setting Up the ZigBee Ethernet Gateway MAN-01-00030-1.4 This manual describes how to install and set up ZigBee communication between a SolarEdge device (Inverters or Safety and Monitoring Interface) and
PCMCIA Wireless LAN Card User s Manual
PCMCIA Wireless LAN Card User s Manual Rev 1.0 Regulatory compliance FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
Wireless Technologies for Industrial Applications
Wireless Technologies for Industrial Applications Mats Andersson, CTO, connectblue Phone: +46 40 630 71 00 Email: [email protected] Web: www.connectblue.com Version 2.2 February 2013 Abstract
The Internet of Things: Opportunities & Challenges
The Internet of Things: Opportunities & Challenges What is the IoT? Things, people and cloud services getting connected via the Internet to enable new use cases and business models Cloud Services How is
Wireless Technologies for Automation
Wireless Technologies for Automation Prof. Dr.-Ing. Jörg F. Wollert Wireless Technologies for Automation Why using wireless communication? Pros and cons in wireless networks Embedded Wireless Hardware
A Beginner s guide to send data to Device Cloud from a ZigBee Network
A Beginner s guide to send data to Device Cloud from a ZigBee Network 1 Document History Date Version Change Description Author 12 Sep 14 1.0 Initial Release Ankur Mathur Copyright 2014 Digi International
Implementation of Wireless Gateway for Smart Home
Communications and Network, 2013, 5, 16-20 doi:10.4236/cn.2013.51b005 Published Online February 2013 (http://www.scirp.org/journal/cn) Implementation of Wireless Gateway for Smart Home Yepeng Ni 1, Fang
Short range low power wireless devices and Internet of Things (IoT)
Short range low power wireless devices and Internet of Things (IoT) White paper Author Mats Andersson Senior Director Technology, Product Center Short Range Radio, u-blox Abstract This paper discusses
Application of the Bluetooth Technology in Telemedicine
Volume 45, Number 4, 2004 475 Application of the Bluetooth Technology in Telemedicine Adina AŞTILEAN, Tiberiu LEŢIA, Honoriu VĂLEAN and Camelia AVRAM Technical University of Cluj Napoca, Automation Department
TECHNICAL NOTE. GoFree WIFI-1 web interface settings. Revision Comment Author Date 0.0a First release James Zhang 10/09/2012
TECHNICAL NOTE GoFree WIFI-1 web interface settings Revision Comment Author Date 0.0a First release James Zhang 10/09/2012 1/14 Web interface settings under admin mode Figure 1: web interface admin log
FLYPORT Wi-Fi 802.11G
FLYPORT Wi-Fi 802.11G System on module 802.11g WIFI - Infrastructure mode - softap mode - Ad hoc mode Microchip PIC 24F 16 bit processor Microchip MRF24WG0MA/MB - Native WiFi 802.11g transceiver - PCB
Wired & Wireless LAN Connections
Lecture 5 Wired & Wireless LAN Connections Network Interface Card (NIC) Ethernet Wiring - Thick Ethernet - Thin Ethernet - Star (Hub) Ethernet Extending LAN - Fiber Modem - Repeater - Bridge - Switch Short
Chapter 7 Low-Speed Wireless Local Area Networks
Wireless# Guide to Wireless Communications 7-1 Chapter 7 Low-Speed Wireless Local Area Networks At a Glance Instructor s Manual Table of Contents Overview Objectives s Quick Quizzes Class Discussion Topics
Wireless Ethernet LAN (WLAN) General 802.11a/802.11b/802.11g FAQ
Wireless Ethernet LAN (WLAN) General 802.11a/802.11b/802.11g FAQ Q: What is a Wireless LAN (WLAN)? Q: What are the benefits of using a WLAN instead of a wired network connection? Q: Are Intel WLAN products
Fig. 1 BAN Architecture III. ATMEL BOARD
Volume 2, Issue 9, September 2014 ISSN: 2321 7782 (Online) International Journal of Advance Research in Computer Science and Management Studies Research Article / Survey Paper / Case Study Available online
First of all Let's look at how you would connect your laptop via Ethernet, as it is the easier of the two methods.
How to get a Internet Connection on your laptop This guide will help you to get an internet connection on your laptop either via Wi-Fi (e.g. in a café or hotel) or via Ethernet (the RJ45 type connector
Wireless Field Data Backhaul
October 2014 Page 1 Smart Wireless Gateway 1552WU An Emerson Smart Solution integrates WirelessHART data from remote areas of your plant. Scalable Reduced cost Safer deployment Secure and reliable communications
Designing and Embodiment of Software that Creates Middle Ware for Resource Management in Embedded System
, pp.97-108 http://dx.doi.org/10.14257/ijseia.2014.8.6.08 Designing and Embodiment of Software that Creates Middle Ware for Resource Management in Embedded System Suk Hwan Moon and Cheol sick Lee Department
Wireless Home Security and Automation System Utilizing ZigBee based Multi-hop Communication
Wireless Home Security and Automation System Utilizing ZigBee based Multi-hop Communication Rozeha A. Rashid, Mohd Adib B. Sarijari, Mohd Rozaini Abd Rahim Faculty of Electrical Engineering University
Plc Based Monitoring and Controlling System Using Wi-Fi Device
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE) e-issn: 2278-2834,p- ISSN: 2278-8735.Volume 9, Issue 4, Ver. II (Jul - Aug. 2014), PP 29-34 Plc Based Monitoring and Controlling System
ANDROID LEVERED DATA MONITORING ROBOT
ANDROID LEVERED DATA MONITORING ROBOT 1 HIMANI PATHAK, 2 VIDYALAKSHMI KRISHNAKUMAR, 3 SHILPA RAVIKUMAR, 4 AJINKYA SHINDE 1,2,3,4 Electronics & Telecommunication Engineering, Fr. C. R. Institute of Technology,
White Paper. D-Link International Tel: (65) 6774 6233, Fax: (65) 6774 6322. E-mail: [email protected]; Web: http://www.dlink-intl.
Introduction to Voice over Wireless LAN (VoWLAN) White Paper D-Link International Tel: (65) 6774 6233, Fax: (65) 6774 6322. Introduction Voice over Wireless LAN (VoWLAN) is a technology involving the use
a Unified Home Gateway Series Introduction: Market Drivers and Tech Challenges Carol Ansley, Sr. Director Advanced Architecture, ARRIS
Managing Improving Cable Home TV Migration Networking to Satisfaction IP Part 1 with a Unified Home Gateway Series Introduction: Market Drivers and Tech Challenges Carol Ansley, Sr. Director Advanced Architecture,
Questions from The New SensorTag - IoT Made Easy Webinar
Questions from The New SensorTag - IoT Made Easy Webinar Are there any plans to make a Windows API available (preferably portable for use in Windows 10 Universal applications) It is in our queue of projects,
Cisco Aironet Wireless Bridges FAQ
Cisco Aironet Wireless Bridges FAQ Document ID: 16041 Contents Introduction What is the Cisco Aironet Wireless Bridge? What are the different platforms of wireless bridges that Cisco offers? Where can
A Study of the Design of Wireless Medical Sensor Network based u- Healthcare System
, pp.91-96 http://dx.doi.org/10.14257/ijbsbt.2014.6.3.11 A Study of the Design of Wireless Medical Sensor Network based u- Healthcare System Ronnie D. Caytiles and Sungwon Park 1* 1 Hannam University 133
Wireless LAN 802.11g USB Adapter
Wireless LAN 802.11g USB Adapter User s Guide Version 1.0 User s Guide 0 Copyright statement No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
Nagpur, Maharashtra, India
Volume 6, Issue 2, February 2016 ISSN: 2277 128X International Journal of Advanced Research in Computer Science and Software Engineering Research Paper Available online at: www.ijarcsse.com Automated Door
OEM MAXNIBP Frequently Asked Questions
Frequently Asked Questions Why does the monitor sometimes inflate the BP cuff, then shortly thereafter reinflate the cuff? How will I know if the monitor is experiencing motion artifact during a measurement?
Thingsquare Technology
Thingsquare Technology Thingsquare connects smartphone apps with things such as thermostats, light bulbs, and street lights. The devices have a programmable wireless chip that runs the Thingsquare firmware.
Iknaia Asset and Personnel Tracking Management System for the Healthcare Industry
Iknaia Asset and Personnel Tracking Management System for the Healthcare Industry July 2014 Introduction Trying to find your way around a large hospital or locating a high-value medical device such as
Cisco Wireless Control System (WCS)
Data Sheet Cisco Wireless Control System (WCS) PRODUCT OVERVIEW Cisco Wireless Control System (WCS) Cisco Wireless Control System (WCS) is the industry s leading platform for wireless LAN planning, configuration,
920MHz Band Multi-hop Wireless Network System
920MHz Band Multi-hop Wireless Network System Hiroshi Hashizume Motohiro Inokuma Masayuki Suto Shigeru Fukunaga Motoharu Kawanishi One policy aimed at the growth of OKI Group is the development of a smart
Wireless LAN advantages. Wireless LAN. Wireless LAN disadvantages. Wireless LAN disadvantages WLAN:
WLAN: Wireless LAN Make use of a wireless transmission medium Tipically restricted in their diameter: buildings, campus, single room etc.. The global goal is to replace office cabling and to introduce
Zigbee-Based Wireless Distance Measuring Sensor System
Zigbee-Based Wireless Distance Measuring Sensor System Ondrej Sajdl 1, Jaromir Zak 1, Radimir Vrba 1 1 Department of Microelectronics, Brno University of Technology, FEEC, Udolni 53, 602 00 Brno, Czech
LTE, WLAN, BLUETOOTHB
LTE, WLAN, BLUETOOTHB AND Aditya K. Jagannatham FUTURE Indian Institute of Technology Kanpur Commonwealth of Learning Vancouver 4G LTE LTE (Long Term Evolution) is the 4G wireless cellular standard developed
A Survey of Cloud Based Health Care System
A Survey of Cloud Based Health Care System Chandrani Ray Chowdhury Assistant Professor, Dept. of MCA, SDET-Brainware Group of Institution, Barasat, West Bengal, India ABSTRACT: Cloud communicating is an
Use case possibilities with Bluetooth low energy in IoT applications
Use case possibilities with Bluetooth low energy in IoT applications White paper Author Mats Andersson Senior Director Technology, Product Center Short Range Radio, u-blox Abstract With yearly shipments
Semaphore T BOX Applications in Data Center Facilities
Semaphore T BOX Applications in Data Center Facilities Introduction Data centers must reliably provide 24/7/365 operation. For automation and monitoring of the facility, use of a rugged, reliable RTU is
Preparing the Computers for TCP/IP Networking
Configuration Preparing the Computers for TCP/IP Networking Configuring Windows 98, and ME for TCP/IP Networking Verifying TCP/IP Properties Configuring Windows 2000 or XP for IP Networking Install or
Remote Patient Monitoring- An Implementation in ICU Ward
2011 International Conference on Information and Network Technology IPCSIT vol.4 (2011) (2011) IACSIT Press, Singapore Remote Patient Monitoring- An Implementation in ICU Ward Arun E 1+, Marimuthu V 2,
High rate and Switched WiFi. WiFi 802.11 QoS, Security 2G. WiFi 802.11a/b/g. PAN LAN Cellular MAN
Security Issues and Quality of Service in Real Time Wireless PLC/SCADA Process Control Systems Dr. Halit Eren & Dincer Hatipoglu Curtin University of Technology (Perth Australia) 2/27/2008 1 PRESENTATION
Easy and efficient asset management for your business
Easy and efficient asset management for your business PERFORMANCE MADE SMARTER Featuring Monitoring of process values Diagnostics Device programming Simulation of process values TEMPERATURE I.S. INTERFACES
The Heartbeat behind Portable Medical Devices: Ultra-Low-Power Mixed-Signal Microcontrollers
The Heartbeat behind Portable Medical Devices: Ultra-Low-Power Mixed-Signal Microcontrollers The proliferation of sophisticated yet affordable personal medical devices is transforming the health care industry,
XBee Wireless Sensor Networks for Temperature Monitoring
XBee Wireless Sensor Networks for Temperature Monitoring Vongsagon Boonsawat, Jurarat Ekchamanonta, Kulwadee Bumrungkhet, and Somsak Kittipiyakul School of Information, Computer, and Communication Technology
DEVELOPMENT OF VIBRATION REMOTE MONITORING SYSTEM BASED ON WIRELESS SENSOR NETWORK
International Journal of Computer Application and Engineering Technology Volume 1-Issue1, January 2012.pp.1-7 www.ijcaet.net DEVELOPMENT OF VIBRATION REMOTE MONITORING SYSTEM BASED ON WIRELESS SENSOR NETWORK
ENHWI-N3. 802.11n Wireless Router
ENHWI-N3 802.11n Wireless Router Product Description Encore s ENHWI-N3 802.11n Wireless Router s 1T1R Wireless single chip can deliver up to 3x faster speed than of 802.11g devices. ENHWI-N3 supports home
54M/150M/300Mbps USB WIRELESS ADAPTER. User s Manual Version 2.0
54M/150M/300Mbps USB WIRELESS ADAPTER User s Manual Version 2.0 1. Introduction User s Manual Thank you for purchasing the IEEE 802.11b/g or 802.11n. This Wireless Adapter is easy to use and easy to setup.
Home Passport Gateway Series Simplify your Life with Smart Solutions
Home Passport Gateway Series Simplify your Life with Smart Solutions HPGW Series - Home Passport Gateway Series HPGW Series is Home Passport Gateway, representing a breakthrough product in the intrusion
ANDROID APPLICATION DEVELOPMENT FOR ENVIRONMENT MONITORING USING SMART PHONES
ANDROID APPLICATION DEVELOPMENT FOR ENVIRONMENT MONITORING USING SMART PHONES ABSTRACT K. Krishnakanth 1 and P. Kavipriya 2 1 M.E Embedded Systems, Sathyabama University, Chennai, India. [email protected]
Online Communication of Critical Parameters in Powerplant Using ZIGBEE
International Journal of Engineering Science Invention Volume 2 Issue 2 ǁ February. 2013 Online Communication of Critical Parameters in Powerplant Using ZIGBEE D.Santhiya 1, R.Renita Priyatharshini 2,K.C.Dhivya
XBEE 802.15.4 PROTOCOL COMPARISON
Connect with Confidence XBEE 802.15.4 PROTOCOL COMPARISON Abstract Creating wireless networks can be done using a variety of RF protocols. Some protocols are proprietary to individual vendors, others are
Wireless bedside Vital Signs monitoring unit
Wireless bedside Vital Signs monitoring unit A. Trigo 1, J.P. Cunha 1,2, M.B.Cunha 1,2, William Xavier 1 and Nuno Silva Ferreira 1 1 IEETA Instituto de Engenharia Electrónica e Telemática de Aveiro 2 Departamento
Logitech Advanced 2.4 GHz Technology With Unifying Technology
Logitech Advanced 2.4 GHz Technology Revision 070709 July 7, 2009 TABLE OF CONTENTS 1 INTRODUCTION: THE MOVE TO WIRELESS PERIPHERALS IN BUSINESS...3 2 SYSTEM OVERVIEW...4 2.1 NETWORK TOPOLOGY...4 2.2 MAIN
Effective System for Pregnant Women using Mobile GIS
Effective System for Pregnant Women using Mobile GIS Ayad Ghany Ismaeel Department of Information System Engineering- Erbil Technical College- Hawler Polytechnic University (previous FTE- Erbil), Iraq.
Lesson 6: 6 EXAMPLES OF EMBEDDED SYSTEMS. Chapter-1L06: "Embedded Systems - ", Raj Kamal, Publs.: McGraw-Hill Education
Lesson 6: 6 EXAMPLES OF EMBEDDED SYSTEMS 1 Telecom Smart Cards, Examples Missiles and Satellites, Computer Networking, Digital Consumer Electronics, and Automotive 2 3 Exemplary Application Areas Also
