Transcription
1 Cable-In-Conduit Solutions
2 Cable-In-Conduit Solutions
3 Southwire Company One Southwire Drive, Carrollton, GA Printed in the USA, Southwire Company, LLC. All Rights Reserved. Registered Trademark and Trademark of Southwire Company, LLC. National Electric Code and NEC are registered trademarks of the National Fire Protection Association, Inc., Quincy, MA CIC-CA02
4 NOTES 30
5 FAQS 1. IS IT UL LISTED? HDPE made to ASTM and UL standards extruded over UL cables are UL listed according to NEC article 354 NUCC. UL markings are available on Schedule 40 duct only and are available upon request. 2. HOW IS IT TERMINATED? SIMpull Cable-in-Conduit can be stubbed up directly into pole bases, pull boxes, and transformer pads. If necessary, compression or glue-on fittings are available. 3. WHAT CABLES ARE AVAILABLE PRE-INSTALLED? We can extrude our duct over nearly all of the cables in our catalog. 4. HOW MANY CABLES CAN I GET INSIDE? Cable fill is limited to NEC fill tables. 5. WHAT SIZES DOES IT COME IN? SIMpull Cable-in-Conduit is currently available in 3/4" thru 3". 6. HOW FLEXIBLE IS IT? Conduit bend radius is 10 times the OD of the duct, which allows bends to be made that are similar to industry sweep elbows. Conduit will easily follow contours of a trench and be directed around obstacles. 7. CAN YOU USE IT IN COLD WEATHER? While HDPE conduit stiffens in extreme cold, it remains flexible for installation to temperatures of -25 C. 8. CAN YOU USE IT INDOORS? No! Outdoor uses only. 9. HOW MUCH CAN I GET ON A REEL? It depends on the size of the duct. For a general reference, please see the chart on page 27 of this catalog. 10. DOES IT HAVE A MEMORY? While CIC will lay nicely in a trench, the cut ends will exhibit a slight bend. This bend is used as an advantage during installation to create sweeps. The material will relax over time to its original straight position. 11. CAN I GET EXACT LENGTHS? Exact cut lengths are available from stocked master reels. Most made to order custom configurations will have a tolerance of 5-10% HOW CAN IT BE INSTALLED? CIC can be installed in open trench, directionally bored, or plowed into the ground. 13. WHAT COLORS ARE AVAILABLE? Southwire conduit is available in black, red, orange, and grey. Striping is also available. 14. ARE THE REELS RETURNABLE? Wood reels and steel-spoked reels are recyclable or available for reel recovery through our partnership with Sonoco. Recovery is subject to end-user location, condition, and number of reels available for return. Please call your sales rep for details. 15. CAN YOU PULL THE CONDUCTORS OUT AFTER THEY ARE INSTALLED? Conductors are pre-lubed prior to extrusion and installed loosely inside the conduit so that they are easily removed, if needed. 16. CAN YOU INSTALL MV CABLES IN CIC? Yes, medium voltage cables can be installed. 17. WHAT IS THE PROPER WAY TO EXPOSE THE CONDUCTORS? Care needs to used when removing conduit so as not to damage the conductors. Southwire recommends the use of a pipe cutter to score the conduit deep enough that the duct can be snapped off before completely cutting through the plastic. 18. SHOULD HDPE DUCT BE PAID OFF THE TOP OR THE BOTTOM OF THE REEL? It will depend on the method of installation. For open trenches, pay off from the bottom of the reel. For plowed installations, pay off from the top of the reel. For directional boring, either method can be used. When pulling into a vault, pay off from the top of the reel. 19. WHY DO I NEED TO CUT BOTH ENDS OF THE CABLE FREE? The cable needs to be able to move freely inside the conduit. If one side is tied, it may cause the conduit to snake resulting in damage to the cable and/or conduit. 20. WHY IS THERE MORE CONDUIT THAN CABLE? Due to the installation process there is approximately 1.5% more conduit than cable. This is taken into account during production and tagged reel lengths are based on the cable installed. This excess duct is carried at the pay-off end of the reel and should be taken into account when starting a run. (A 600' run should have approximately a 9' length of duct at the beginning end).
6 GLOSSARY FAQS & GLOSSARY HDPE...High Density Polyethylene Directional Boring... Create an underground tunnel to pull duct into without disturbing surface structures. Plowing... A method of installing duct that uses a large plow with a chute to feed the duct directly into the ground in a narrow trench created by the plow blade. Trenching... An open trench created by a backhoe or a trencher Trencher... A piece of construction equipment used to dig trenches, especially for laying pipes or cables PVC...Polyvinyl Chloride DOT...Department of Transportation SDR... Dimensional ratio: Wall thickness increases as OD increases ASTM... ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. NPS... Nominal Pipe Size: Diameter of pipe in inches Schedule Wall thickness based on UL and ASTM standards Schedule Wall thickness based on UL and ASTM standards TC-7 STD Wall... Wall thickness based on Nema TC-7 thinnest wall SDR Wall thickness based on Nema TC-7: Wall thickness increases in proportion to the diameter; thinner wall than 11 SDR Wall thickness based on Nema TC-7: Wall thickness increases in proportion to the diameter; thicker wall than 13.5 UL...Underwriters Laboratories NEMA...National Electrical Manufacturers Association Metal-Spoked Reels... Non-returnable reels for SIMpull Cable-in-Conduit and empty duct with adjustable drum size to accommodate different sized conduit MV...Medium Voltage 5 kv to 69 kv PSI... Pounds per square inch. A measurement of pressure Bend Radius... The minimum radius a conduit can be bent without compromising duct. THW-2... Thermoplastic insulation (usually PVC), heat resistant (90 C rating), suitable for wet locations THWN-2... Same as THW except nylon jacket over reduced insulation thickness. Also rated THHN. THHN... Thermoplastic insulation (usually PVC), high heat resistant (90 C rating), dry locations only, nylon jacket. Also rated THWN. TFFN... Thermoplastic insulation (usually PVC), fixture wire, nylon jacket. Also rated MTW and AWM. TFN... Thermoplastic insulation (usually PVC), fixture wire, nylon jacket. Also rated AWM. XHHW-2... Cross-linked polyethylene insulation (X), high heat resistant (90 C rating) for wet and dry locations. RHH... Rubber insulation (we actually use crosslinked polyethylene because it qualifies for rubber), heat resistant (90 C rating) for dry locations only. RHW-2... Rubber insulation (cross-linked polyethylene is used by most manufacturers), heat resistant (90 C), suitable for wet locations. USE-2... Underground Service Entrance. Most utilize cross-linked polyethylene insulation rated for 90 C in direct burial applications. Product is usually triple rated RHH-RHW-2-USE-2. UD...Underground NEC...National Electrical Code RoHS...Restriction of Hazardous Substances XLP...Cross-linked Polyethylene AWG...American Wire Gauge CSA...Canada Standards Association HMWPE...High Molecular Weight Polyethylene ICEA...Insulated Cable Engineers Association ANSI...American Nation Standard Institute TRXLP...Tree-retardant Cross-linked Polyethylene AEIC... Association of Edison Illuminating Companies EPR...Ethylene Propylene Rubber PV...Photovoltaic UF...Underground Feeder PSI...Pounds per Square Inch Cross-Linking... Inter-molecular bonds between long-chain thermoplastic polymers due to chemical or electro bombardment; the properties of the resulting thermo-setting material are usually improved. Circular Mil... The area of a circle one thousandth of an inch in diameter Mil... A unit used in measuring diameter of a wire or thickness of insulation over a conductor; one one-thousandth of an inch (.001") Kcmil... A unit of conductor area in thousands of circular mils FAQS & GLOSSARY 29
7 REELS All products are available on wooden, poly-fiber, or metal-spoked reels as shown. All Southwire Cable-in-Conduit and empty duct have end caps applied during the manufacturing process to keep moisture and contaminates from entering the duct while not in use. Reels are tagged with weatherproof placards that display pertinent information regarding the product. Reel wrap may also be available upon request. 26
8 REELS STANDARD SOUTHWIRE REEL DIMENSIONS AND WEIGHT CHART LENGTH (feet) WEIGHTS, MEASUREMENTS, AND PACKAGING 0.75 INCH 1 INCH 1.25 INCHES 1.5 INCHES 2 INCHES 2.5 INCHES 3 INCHES 4 INCHES REELS # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # Flange Traverse Drum *Other lengths may be available upon request. **Chart is for reference only. Southwire has the right to substitute similar reels as needed. 27
9 STANDARD END CAPS APPLICATIONS Standard end caps are used to keep contaminates and water out of the duct when the reel is not in use. Standard ends can be used with any cable configuration in duct. PRODUCT DETAILS Available in sizes 3/4", 1", 1 1/2", 2" and 2 1/2" Adaptable, Push-On Style Caps Flexible PVC Weather-Tight Seal 24
10 CONDUIT ACCESSORIES STANDARD END CAPS REFERENCE DESCRIPTIONS SIZE G G G G G STANDARD END CAPS 25
11 E-LOC QUICK SEAL TERMINATION FITTINGS & DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS APPLICATIONS E-LOC QUICK SEAL TERMINATION FITTINGS Quick Seal Terminations join HDPE to assorted cabinets or meter bases. Quick Seal Terminations incorporate E-Loc or Double E-Loc features to create a weather-resistant seal. PRODUCT DETAILS DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS E-LOC QUICK SEAL TERMINATION FITTINGS HDPE male termination Threaded lock-nut connection No additional tools required Available in 3/4" to 2 1/2" DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS Locking compression HDPE male termination Threaded lock-nut connection No additional tools required Available in 1 1/4" to 2" Weather-Resistant Seal HDPE Threaded Lock-Nut Connection 22
12 CONDUIT ACCESSORIES E-LOC QUICK SEAL TERMINATION FITTINGS REFERENCE DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS DESCRIPTIONS NOMINAL SIZE ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor REFERENCE DESCRIPTIONS NOMINAL SIZE DETA Locking compression HDPE terminal adaptor DETA Locking compression HDPE terminal adaptor DETA Locking compression HDPE terminal adaptor TYPE TYPE E-LOC QUICK SEAL TERMINATION FITTINGS & DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS 23
13 E-LOC TRANSITION FITTINGS & DOUBLE E-LOC TRANSITION FITTINGS APPLICATIONS E-LOC TRANSITION FITTINGS E-Loc and Double E-Loc transition fittings provide a threaded transition between any IPS tapered threaded rigid pipe and HDPE or a male solvent weld transition between PVC and HDPE pipe. One side of the transition fitting is a compression coupling and the other side is either a glued or threaded coupling allowing for a watertight connection of dissimilar material. PRODUCT DETAILS DOUBLE E-LOC TRANSITION FITTINGS E-LOC TRANSITION FITTINGS HDPE to threaded rigid pipe HDPE to solvent welded connection HDPE to PVC Size ranging from 3/4" to 2" No additional tools required for installation Airtight Connections DOUBLE E-LOC TRANSITION FITTINGS Locking compression HDPE to rigid pipe Locking compression HDPE to solvent weld Size ranging from 1 1/4" to 2" No addition tools required for installation Low Profile Excellent Pull-Out Resistance 20
14 CONDUIT ACCESSORIES E-LOC TRANSITION FITTINGS REFERENCE DOUBLE E-LOC TRANSITION FITTINGS DESCRIPTIONS NOMINAL SIZE ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end REFERENCE DESCRIPTIONS NOMINAL SIZE DEL MPT HDPE to any IPS threaded pipe DEL MPT HDPE to any IPS threaded pipe DEL MPT HDPE to any IPS threaded pipe DEL MSW HDPE to PVC standard or bell end DEL MSW HDPE to PVC standard or bell end DEL MSW HDPE to PVC standard or bell end TYPE TYPE E-LOC TRANSITION FITTINGS & DOUBLE E-LOC TRANSITION FITTINGS 21
15 DOUBLE E-LOC & DOUBLE E-LOC TRANSITION COUPLINGS APPLICATIONS DOUBLE E-LOC COUPLINGS The Double E-Loc is a locking compression coupling used to join smooth, ribbed, corrugated or Figure 8 High Density Polyethylene (HDPE) conduit. The locking, pressure-tight design makes the Double E-Loc an ideal coupling for pneumatic cable placing applications when air and watertight integrity of the system is imperative. Unmatched pressure ratings, pull-out resistance, no metal parts, and no special tools make the Double E-Loc the preferred coupling. Lock rings specially designed to grip rigid PVC and steel pipe are also available. Double E-Loc Transition Couplings have the same great features as the Double E-Loc Couplings, but provide the ability to connect conduit of different sizes. Lock rings designed to grip PVC and steel allow for a single coupling to transition to both a dissimilar size and dissimilar material. DOUBLE E-LOC TRANSITION COUPLINGS PRODUCT DETAILS Can withstand 200 psi internal pressure Provide pull-out resistance in excess of ASTM standards for HDPE Sizes from 3/4" to 2" available No additional tools required for installation Locking Compression Coupling No Special Tools Required Sizes 3/4" to 2" 18
16 CONDUIT ACCESSORIES DOUBLE E-LOC COUPLINGS REFERENCE WEIGHTS, MEASUREMENTS, AND PACKAGING NOMINAL SIZE DOUBLE E-LOC TRANSITION COUPLINGS STANDARD DUCT SIZE LENGTH PIECES PER CARTON WEIGHT PER CARTON (lbs) DEL " O.D. DUCT (1" IPS) DEL " O.D. DUCT (1.25" IPS) DEL " O.D. DUCT (1.5" IPS) DEL " O.D. DUCT (2" IPS) REFERENCE MEASUREMENTS AND PACKAGING FROM TRANSITION SIZE O.D. TO PIECES PER CARTON DEL DEL DEL DEL DEL DOUBLE E-LOC & DOUBLE E-LOC TRANSITION COUPLINGS 19
17 E-LOC & E-LOC TRANSITION COUPLINGS APPLICATIONS E-LOC COUPLINGS E-LOC TRANSITION COUPLINGS Watertight/Airtight Connection Ability to Join Dissimilar Materials The E-Loc Coupling is a compression coupling that provides a watertight/airtight connection in buried, or restrained applications. The ability to join dissimilar materials, such as PVC, HDPE, fiberglass, or metal, makes the E-Loc a versatile coupling for the telephone, electrical, and cable industries. Patented. E-Loc Couplings are available to fit conduit sizes from 3/4" through 4". Easy to install without the need for additional tools or equipment. Watertight to 200 psi restrained on smooth wall conduit. Also seals on ribbed and corrugated duct. Custom lengths and non-standard IPS diameters are available. Allows for transitions between different materials with one coupling. E-Loc Transition Couplings have all the great features of an E-Loc Coupling while providing a transition from one size conduit to another. This includes the ability to transition to dissimilar materials such as PVC, HDPE, fiberglass, and metal. Allows for transitions between different sizes and materials with one coupling. PRODUCT DETAILS Can join ducts made from dissimilar materials Can withstand 200 psi restrained on smooth wall conduit Size range from 3/4" through 4" Transitions between sizes available No additional tooling required for installation Easy Installation Custom Lengths and Non-Standard IPS Diameters Available 16
18 CONDUIT ACCESSORIES E-LOC COUPLINGS REFERENCE WEIGHTS, MEASUREMENTS, AND PACKAGING NOMINAL SIZE E-LOC TRANSITION COUPLINGS STANDARD DUCT SIZE COUPLING BODY O.D. LENGTH PIECES PER CARTON WEIGHT PER CARTON (lbs) EL " 3/4" IPS EL " 1" IPS & SCH EL " 1.25" IPS EL " 1.5" IPS EL " 2" IPS EL " 2.5" IPS EL " 3" IPS EL " 3" IPS x 8" LG EL " 3" IPS x 12" LG ELR " REPAIR SLEEVE EL " 4" IPS *Standard coupling length is 6" unless noted otherwise. REFERENCE DESCRIPTIONS DESCRIPTION E-LOC & E-LOC TRANSITION COUPLINGS ELA CPLG, E-LOC TRANS 1.660" x 1.050" ELA CPLG, E-LOC TRANS 1.660" x 1.315" ELA CPLG, E-LOC TRANS 1.900" x 1.315" ELA CPLG, E-LOC TRANS 1.900" x 1.660" ELA CPLG, E-LOC TRANS 2.375" x 1.315" ELA CPLG, E-LOC TRANS 2.375" x 1.660" ELA CPLG, E-LOC TRANS 2.375" x 1.900" ELA CPLG, E-LOC TRANS 2.875" x 2.375" ELA CPLG, E-LOC TRANS 3.500" x 1.900" ELA CPLG, E-LOC TRANS 3.500" x 2.375" ELA CPLG, E-LOC TRANS 3.500" x 2.875" ELA CPLG, E-LOC TRANS 4.500" x 2.375" ELA CPLG, E-LOC TRANS 4.500" x 2.875" ELA CPLG, E-LOC TRANS 4.500" x 3.500" 17
19 COPPER-CLAD STEEL TRACER WIRE BLUE INSULATION RED INSULATION APPLICATIONS Used as tracer wire to locate buried conduit 30 volt constructions suitable for direct burial 30 or 600 volt rating (depending on insulation thickness) ORANGE INSULATION BLACK INSULATION INDUSTRY APPROVALS Southwire s Copper-Clad Steel Tracer Wire meets or exceeds the following applicable ASTM specifications: B 869: Copper-Clad Steel Wire for Cable TV Drop Wire B 910: Annealed Copper-Clad Steel Wire UL Listed for Tracer Wire GREEN INSULATION Copper-Clad Steel Solid Conductor CONSTRUCTION Copper-clad steel solid conductor 18 AWG to 10 AWG 21% conductivity annealed Low carbon (LC) Insulated with high molecular weight polyethylene (HMWPE) Color options: yellow, blue, red, orange, black, green UL Listed Insulated with HMWPE Color Options Available: Yellow, Blue, Red, Orange, Black, Green CONDUIT Fiber Optic Cable CATV/Telephone Gas Electric Water Sewer COLORS COLOR OPTIONS orange orange yellow black, red blue green 14
20 CONDUIT SOLUTIONS SIZE (AWG) WEIGHTS AND MEASUREMENTS CONDUCTOR NOMINAL O.D. INSULATION THICKNESS 30 VOLTS OVERALL NOMINAL O.D. APPROX. WEIGHT (lbs/1000 ft) VOLTS COPPER-CLAD STEEL TRACER WIRE 15
21 COPPER TRACER WIRE BLUE INSULATION RED INSULATION APPLICATIONS Used as tracer wire to locate buried conduit 30 volt constructions suitable for direct burial 30 or 600 volt depending on insulation thickness ORANGE INSULATION BLACK INSULATION INDUSTRY APPROVALS Southwire's soft-drawn copper tracer wire meets or exceeds the following ASTM specifications: B 3: Soft or Annealed copper wire UL listed as tracer wire GREEN INSULATION CONSTRUCTION Soft drawn copper solid conductor 16 AWG to 8 AWG Insulated with high molecular weight polyethylene (HMWPE) Color options: yellow, blue, red, orange, black, green Soft Drawn Copper Wire UL Listed Fiber Optic Cable COLOR OPTIONS orange Insulated with HMWPE Color Options Available: Yellow, Blue, Red, Orange, Black, Green CONDUIT CATV/Telephone Gas Electric Water Sewer COLORS orange yellow black, red blue green 12
22 CONDUIT SOLUTIONS SIZE (AWG) WEIGHTS AND MEASUREMENTS CONDUCTOR NOMINAL O.D. INSULATION THICKNESS 30 VOLTS OVERALL NOMINAL O.D. APPROX. WEIGHT (lbs/1000 ft) VOLTS COPPER TRACER WIRE 13
23 PULL TAPE CONSTRUCTION PRE-INSTALLED IN CONDUIT AVAILABLE ON A REEL High strength measuring and flat woven pulling tape 100% polyester for low absorption of moisture Resistant to conduit cutting/burning-through during pulling Low elongation for safety and accuracy Printed with sequential footage markings for easy locating OPTIONS Available in 1130#, 1250#, 1800#, and 2500# tensile strength 1800# and 2500# tape also available with a locatable tracer wire pre-installed Available on a reel Available pre-installed in conduit Reel Pre-Installed in Conduit High-Strength Flat Woven Sequential Footage Markings 10
24 CONDUIT SOLUTIONS WEIGHTS, MEASUREMENTS, AND PACKAGING TENSILE STRENGTH (lbs) APPROX. WIDTH SPOOL LENGTH (feet) SPOOL SIZE WEIGHT PER SPOOL (lbs) x x x x x x x x PULL TAPE 11
25 RIBBED CONDUIT & RIBBED CONDUIT WITH PULL TAPE RIBBED RIBBED WITH PULL TAPE APPLICATIONS Commonly installed from transformer to transformer or as underground cables exiting substations INDUSTRY APPROVALS Ribbed ducts are made of high-density polyethylene resin meeting the requirements of ASTM D All conduit is manufactured in accordance with ASTM F Conduit comes in a variety of color options and is made in accordance with NEMA TC-7 and ASTM D Material meets or exceeds the requirements in ASTM D3350 for Class PE435540C (Black) or E (colors with UV Stabilizers). UL Listed CONSTRUCTION HDPE conduit Available as Schedule 40, Schedule 80, SDR 11, and SDR 13.5 HDPE Conduit Ribbed Ribbed with Pull Tape UL Listed Color Options Available: Black, Red, Orange, Gray Striping is Available CONDUIT OPTIONS Available in sizes 3/4" through 4" Ribbed Ribbed with pull tape Available with UL markings on 3/4" through 3" Schedule 40 conduit Color options: black, red, orange, gray. Striping is also available. Available with pull tape pre-installed to eliminate the time and labor of having to install it in the field Fiber Optic Cable CATV/Telephone Electric COLORS COLOR OPTIONS orange orange black, gray, red PROPERTY TEST METHOD VALUE Density D g/cc Melt Index D g/10 min Flexural Modulus D ,000 psi Tensile Strength D in/min SP-NCLS ESCR F2136 >1000 hrs Hydrostatic Design Basis D2837 N/A 8
26 CONDUIT SOLUTIONS NOMINAL SIZE WEIGHTS AND MEASUREMENTS NOMINAL OUTSIDE DIAMETER MINIMUM WALL THICKNESS NOMINAL INSIDE DIAMETER SCHEDULE 40 MINIMUM BENDING RADIUS MAXIMUM PULLING TENSION (lbs) WEIGHT (lbs/1000 ft) SCHEDULE SDR SDR RIBBED CONDUIT & RIBBED CONDUIT WITH PULL TAPE For conduit with ribbed interior reduce Nominal Inside Diameter by 0.050" 9
27 SMOOTH CONDUIT & SMOOTH CONDUIT WITH PULL TAPE SMOOTH SMOOTH WITH PULL TAPE APPLICATIONS Commonly installed from transformer to transformer or as underground cables exiting substations INDUSTRY APPROVALS Smooth wall ducts are made of high-density polyethylene resin meeting the requirements of ASTM D All conduit is manufactured in accordance with ASTM F Standard wall conduit comes in a variety of color options and is made in accordance with NEMA TC-7 and ASTM D Material meets or exceeds the requirements in ASTM D3350 for Class PE435540C (Black) or E (colors with UV Stabilizers). UL Listed CONSTRUCTION HDPE conduit Available as Schedule 40, Schedule 80, SDR 11, and SDR 13.5 HDPE Conduit Smooth Smooth with Pull Tape UL Listed Color Options Available: Black, Red, Orange, Gray Striping is Available CONDUIT OPTIONS Available in sizes 3/4" through 4" Smooth Smooth with pull tape Available with UL markings on 3/4" through 3" Schedule 40 conduit Color options: black, red, orange, gray. Striping is also available. Available with pull tape pre-installed to eliminate the time and labor of having to install it in the field Fiber Optic Cable CATV/Telephone Electric COLORS COLOR OPTIONS orange orange black, gray, red PROPERTY TEST METHOD VALUE Density D g/cc Melt Index D g/10 min Flexural Modulus D ,000 psi Tensile Strength D in/min SP-NCLS ESCR F2136 >1000 hrs Hydrostatic Design Basis D2837 N/A 6
28 CONDUIT SOLUTIONS NOMINAL SIZE WEIGHTS AND MEASUREMENTS NOMINAL OUTSIDE DIAMETER MINIMUM WALL THICKNESS NOMINAL INSIDE DIAMETER SCHEDULE 40 MINIMUM BENDING RADIUS MAXIMUM PULLING TENSION (lbs) WEIGHT (lbs/1000 ft) SCHEDULE SDR SDR SMOOTH CONDUIT & SMOOTH CONDUIT WITH PULL TAPE 7
29 SIMpull CABLE-IN-CONDUIT ALUMINUM SECONDARY CABLES COPPER SECONDARY CABLES APPLICATIONS Refer to pages 2-3 of this catalog INDUSTRY APPROVALS Smooth wall ducts are made of high-density polyethylene resin meeting the requirements of ASTM D All conduit is manufactured in accordance with ASTM F Standard wall conduit comes in a variety of color options and is made in accordance with NEMA TC-7 and ASTM D UL Listed CONSTRUCTION Manufactured by continuously extruding HDPE loosely around the cable assembly with no adhesion between the conduit and the cable, thus leaving the cables free in the conduit. Lubrication is applied to the cable, allowing for cables to be pulled out and replaced if necessary. All cables are installed as single conductors or paralleled in HDPE conduit and are available in Standard Wall, Schedule 40, Schedule 80, SDR 13.5, SDR 11, and SDR 17. Single Conductors or Paralleled HDPE Conduit Color Options Available: Black, Red, Orange, Gray Striping is Available CONDUIT OPTIONS 600 V, MV, Fiber, and Specialty Cables Available with UL marking on 3/4" through 3" Schedule 40 conduit Color options available: black, red, orange, gray. Striping is also available. Fiber Optic Cable CATV/Telephone Electric COLORS COLOR OPTIONS orange orange black, gray, red PROPERTY TEST METHOD VALUE Density D g/cc Melt Index D g/10 min Flexural Modulus D ,000 psi Tensile Strength D in/min SP-NCLS ESCR F2136 >1000 hrs Hydrostatic Design Basis D2837 N/A 4
30 CONDUIT SOLUTIONS NOMINAL SIZE WEIGHTS AND MEASUREMENTS NOMINAL OUTSIDE DIAMETER MINIMUM WALL THICKNESS NOMINAL INSIDE DIAMETER MINIMUM BENDING RADIUS MAXIMUM PULLING TENSION (lbs) WEIGHT (lbs/1000 ft) STANDARD WALL NEMA TC SCHEDULE SCHEDULE SDR SDR SDR SIMpull CABLE-IN-CONDUIT 5
31 CABLE-IN-CONDUIT APPLICATIONS WIND Common Cables: Fiber, AL PV, AL MV TRXLP Applications: Collection of Power Generated by Wind Turbines SOLAR Common Cables: AL PV, Fiber, AL THHN, CU THHN, AL MV TRXLP, AL MV EPR, AL RWU90, AL USE, CU USE Applications: Collection of Power Generated by Solar Panels UTILITY SERVICE Common Cables: Al MV TRXLP, AL MV EPR, AL 600VUD Applications: Underground Distribution of Power AG IRRIGATION Common Cables: AL 600VUD, AL RWU90, CU THHN, CU UF, CU TC, AL XHHW Applications: Providing Power to Irrigation Pivots D.O.T. Common Cables: CU USE, CU THHN, CU MV90, CU XHHW, Fiber Applications: Fiber Backbones, Long Haul Fiber, High-mast Lighting, Highway Lighting AIRPORT Common Cables: CU L-824, CU USE, CU XHHW Applications: Runway Lighting, Volt Power, Apron Lighting 2
32 CIC APPLICATIONS UTILITY RESIDENTIAL Common Cables: AL USE, AL RWU90, AL 600VUD Applications: Power to the Home STREETLIGHT Common Cables: CU USE, CU THHN, CU XHHW, AL USE, AL THHN, AL XHHW, AL 600VUD, AL RWU90 Applications: Residential Street Lighting, Campus Lighting, City Park Lighting, Walkway Lighting PARKING DECK Common Cables: CU XHHW, CU USE, CU THHN Applications: Lighting RAILROAD Common Cables: AL MV TRXLP, AL MV EPR, Fiber, Railroad Signal Cable Applications: Railroad Signals, Fiber Backbone, Long Haul Fiber, Power Transmission RV PARK Common Cables: AL MV TRXLP, AL MV EPR, CU MV TRXLP, CU MV EPR, AL 600VUD, AL THHN, AL XHHW, AL USE, AL RWU90 Applications: Main Power Feed, Power to Pedestals TURF IRRIGATION Common Cables: CU THHN Applications: Commercial Sprinkler Systems 3
33 TABLE OF CONTENTS CABLE-IN-CONDUIT SOLUTIONS CIC APPLICATIONS... 2 SIMpull CABLE-IN-CONDUIT... 4 SMOOTH CONDUIT RIBBED CONDUIT WITH & WITHOUT PULL TAPE... 6 WITH & WITHOUT PULL TAPE... 8 PULL TAPE COPPER TRACER WIRE COPPER-CLAD STEEL TRACER WIRE E-LOC & E-LOC TRANSITION COUPLINGS DOUBLE E-LOC & DOUBLE E-LOC TRANSITION COUPLINGS E-LOC TRANSITION FITTINGS & DOUBLE E-LOC TRANSITION FITTINGS QUICK SEAL TERMINATION FITTINGS STANDARD END CAPS REELS FAQS GLOSSARY BENEFITS OF CABLE-IN-CONDUIT 1. Protects cable: During shipment During installation During operation 2. Reduces labor costs by: Eliminating separate handling of both pipe and wire Eliminating assembly of 20' conduit sections Eliminating pulling of wire into duct 3. Can eliminate need for special pulling equipment. 4. Helps reduce freight costs. 5. Allows for various installation methods which may reduce installation and restoration costs. 6. Can reduce replacement and upgrade costs. 7. HDPE conduit is flexible as opposed to rigid PVC pipe. 8. Available in various colors or stripes. 9. Available in continuous lengths. See reel cart in back of this catalog. Ask us if you don't see a cable you need in this catalog. Practically any cable Southwire manufactures can be provided as a cable-in-conduit solution. *Subject to size and weight 1
34 Meet your single-source cable-in-conduit supplier. Our People: Southwire started in 1950 with only 12 employees in Carrollton, Georgia. Today, we employ more than 5,200 people in sales offices, distribution centers and manufacturing facilities throughout North America. And it s our people who continue to make Southwire thrive. By forming close relationships with our customers, we re able to better understand their needs through conversation, observation and research. Our employees remain the vital source behind our innovative products and services. Our Services: Through an unparalleled commitment to excellent service, Southwire is able to fulfill your cable-in-conduit needs. Our simplified ordering process and stocking and kitting services are set up to provide you with exactly the amount of product you need. And with nine distribution centers located through the nation, we offer flexible shipping options to deliver your materials to you exactly when and where you need them. Our Products: Our dedication to increasing safety, productivity and profitability is behind every Southwire product. And as the only single-source provider to manufacture both cable and conduit, our cable-in-conduit solutions are engineered for simplified, safe and low-cost installation. Along with hundreds of configurations available, we also offer customized cable-in-conduit solutions of nearly any wire and cable product in our catalog. Our Innovation: For more than 60 years, Southwire has been dedicated to remaining at the forefront of the industry. And our cable-in-conduit solutions are evidence of that dedication. Our on-site D.B. Cofer Technology Center is the industry leader in new product innovation, development and research. And we are committed to connecting with you to understand your challenges, help simplify your processes and discover new ways to better serve you.
35 Southwire Company One Southwire Drive, Carrollton, GA Printed in the USA, Southwire Company, LLC. All Rights Reserved. Registered Trademark and Trademark of Southwire Company, LLC. National Electric Code and NEC are registered trademarks of the National Fire Protection Association, Inc., Quincy, MA CIC-CA02
36 NOTES 30
37 FAQS 1. IS IT UL LISTED? HDPE made to ASTM and UL standards extruded over UL cables are UL listed according to NEC article 354 NUCC. UL markings are available on Schedule 40 duct only and are available upon request. 2. HOW IS IT TERMINATED? SIMpull Cable-in-Conduit can be stubbed up directly into pole bases, pull boxes, and transformer pads. If necessary, compression or glue-on fittings are available. 3. WHAT CABLES ARE AVAILABLE PRE-INSTALLED? We can extrude our duct over nearly all of the cables in our catalog. 4. HOW MANY CABLES CAN I GET INSIDE? Cable fill is limited to NEC fill tables. 5. WHAT SIZES DOES IT COME IN? SIMpull Cable-in-Conduit is currently available in 3/4" thru 3". 6. HOW FLEXIBLE IS IT? Conduit bend radius is 10 times the OD of the duct, which allows bends to be made that are similar to industry sweep elbows. Conduit will easily follow contours of a trench and be directed around obstacles. 7. CAN YOU USE IT IN COLD WEATHER? While HDPE conduit stiffens in extreme cold, it remains flexible for installation to temperatures of -25 C. 8. CAN YOU USE IT INDOORS? No! Outdoor uses only. 9. HOW MUCH CAN I GET ON A REEL? It depends on the size of the duct. For a general reference, please see the chart on page 27 of this catalog. 10. DOES IT HAVE A MEMORY? While CIC will lay nicely in a trench, the cut ends will exhibit a slight bend. This bend is used as an advantage during installation to create sweeps. The material will relax over time to its original straight position. 11. CAN I GET EXACT LENGTHS? Exact cut lengths are available from stocked master reels. Most made to order custom configurations will have a tolerance of 5-10% HOW CAN IT BE INSTALLED? CIC can be installed in open trench, directionally bored, or plowed into the ground. 13. WHAT COLORS ARE AVAILABLE? Southwire conduit is available in black, red, orange, and grey. Striping is also available. 14. ARE THE REELS RETURNABLE? Wood reels and steel-spoked reels are recyclable or available for reel recovery through our partnership with Sonoco. Recovery is subject to end-user location, condition, and number of reels available for return. Please call your sales rep for details. 15. CAN YOU PULL THE CONDUCTORS OUT AFTER THEY ARE INSTALLED? Conductors are pre-lubed prior to extrusion and installed loosely inside the conduit so that they are easily removed, if needed. 16. CAN YOU INSTALL MV CABLES IN CIC? Yes, medium voltage cables can be installed. 17. WHAT IS THE PROPER WAY TO EXPOSE THE CONDUCTORS? Care needs to used when removing conduit so as not to damage the conductors. Southwire recommends the use of a pipe cutter to score the conduit deep enough that the duct can be snapped off before completely cutting through the plastic. 18. SHOULD HDPE DUCT BE PAID OFF THE TOP OR THE BOTTOM OF THE REEL? It will depend on the method of installation. For open trenches, pay off from the bottom of the reel. For plowed installations, pay off from the top of the reel. For directional boring, either method can be used. When pulling into a vault, pay off from the top of the reel. 19. WHY DO I NEED TO CUT BOTH ENDS OF THE CABLE FREE? The cable needs to be able to move freely inside the conduit. If one side is tied, it may cause the conduit to snake resulting in damage to the cable and/or conduit. 20. WHY IS THERE MORE CONDUIT THAN CABLE? Due to the installation process there is approximately 1.5% more conduit than cable. This is taken into account during production and tagged reel lengths are based on the cable installed. This excess duct is carried at the pay-off end of the reel and should be taken into account when starting a run. (A 600' run should have approximately a 9' length of duct at the beginning end).
38 GLOSSARY FAQS & GLOSSARY HDPE...High Density Polyethylene Directional Boring...Create an underground tunnel to pull duct into without disturbing surface structures. Plowing...A method of installing duct that uses a large plow with a chute to feed the duct directly into the ground in a narrow trench created by the plow blade. Trenching...An open trench created by a backhoe or a trencher Trencher...A piece of construction equipment used to dig trenches, especially for laying pipes or cables PVC...Polyvinyl Chloride DOT...Department of Transportation SDR...Dimensional ratio: Wall thickness increases as OD increases ASTM...ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. NPS...Nominal Pipe Size: Diameter of pipe in inches Schedule 40...Wall thickness based on UL and ASTM standards Schedule 80...Wall thickness based on UL and ASTM standards TC-7 STD Wall...Wall thickness based on Nema TC-7 thinnest wall SDR Wall thickness based on Nema TC-7: Wall thickness increases in proportion to the diameter; thinner wall than 11 SDR Wall thickness based on Nema TC-7: Wall thickness increases in proportion to the diameter; thicker wall than 13.5 UL...Underwriters Laboratories NEMA...National Electrical Manufacturers Association Metal-Spoked Reels... Non-returnable reels for SIMpull Cable-in-Conduit and empty duct with adjustable drum size to accommodate different sized conduit MV...Medium Voltage 5 kv to 69 kv PSI... Pounds per square inch. A measurement of pressure Bend Radius... The minimum radius a conduit can be bent without compromising duct. THW-2... Thermoplastic insulation (usually PVC), heat resistant (90 C rating), suitable for wet locations THWN-2... Same as THW except nylon jacket over reduced insulation thickness. Also rated THHN. THHN... Thermoplastic insulation (usually PVC), high heat resistant (90 C rating), dry locations only, nylon jacket. Also rated THWN. TFFN... Thermoplastic insulation (usually PVC), fixture wire, nylon jacket. Also rated MTW and AWM. TFN... Thermoplastic insulation (usually PVC), fixture wire, nylon jacket. Also rated AWM. XHHW-2... Cross-linked polyethylene insulation (X), high heat resistant (90 C rating) for wet and dry locations. RHH... Rubber insulation (we actually use crosslinked polyethylene because it qualifies for rubber), heat resistant (90 C rating) for dry locations only. RHW-2... Rubber insulation (cross-linked polyethylene is used by most manufacturers), heat resistant (90 C), suitable for wet locations. USE-2... Underground Service Entrance. Most utilize cross-linked polyethylene insulation rated for 90 C in direct burial applications. Product is usually triple rated RHH-RHW-2-USE-2. UD...Underground NEC...National Electrical Code RoHS...Restriction of Hazardous Substances XLP...Cross-linked Polyethylene AWG...American Wire Gauge CSA...Canada Standards Association HMWPE...High Molecular Weight Polyethylene ICEA...Insulated Cable Engineers Association ANSI...American Nation Standard Institute TRXLP...Tree-retardant Cross-linked Polyethylene AEIC... Association of Edison Illuminating Companies EPR...Ethylene Propylene Rubber PV...Photovoltaic UF...Underground Feeder PSI...Pounds per Square Inch Cross-Linking... Inter-molecular bonds between long-chain thermoplastic polymers due to chemical or electro bombardment; the properties of the resulting thermo-setting material are usually improved. Circular Mil... The area of a circle one thousandth of an inch in diameter Mil... A unit used in measuring diameter of a wire or thickness of insulation over a conductor; one one-thousandth of an inch (.001") Kcmil... A unit of conductor area in thousands of circular mils FAQS & GLOSSARY 29
39 REELS All products are available on wooden, poly-fiber, or metal-spoked reels as shown. All Southwire Cable-in-Conduit and empty duct have end caps applied during the manufacturing process to keep moisture and contaminates from entering the duct while not in use. Reels are tagged with weatherproof placards that display pertinent information regarding the product. Reel wrap may also be available upon request. 26
40 REELS STANDARD SOUTHWIRE REEL DIMENSIONS AND WEIGHT CHART LENGTH (feet) WEIGHTS, MEASUREMENTS, AND PACKAGING 0.75 INCH 1 INCH 1.25 INCHES 1.5 INCHES 2 INCHES 2.5 INCHES 3 INCHES 4 INCHES REELS # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # Flange Traverse Drum *Other lengths may be available upon request. **Chart is for reference only. Southwire has the right to substitute similar reels as needed. 27
41 STANDARD END CAPS APPLICATIONS Standard end caps are used to keep contaminates and water out of the duct when the reel is not in use. Standard ends can be used with any cable configuration in duct. PRODUCT DETAILS Available in sizes 3/4", 1", 1 1/2", 2" and 2 1/2" Adaptable, Push-On Style Caps Flexible PVC Weather-Tight Seal 24
42 CONDUIT ACCESSORIES STANDARD END CAPS REFERENCE DESCRIPTIONS SIZE G G G G G STANDARD END CAPS 25
43 E-LOC QUICK SEAL TERMINATION FITTINGS & DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS APPLICATIONS E-LOC QUICK SEAL TERMINATION FITTINGS Quick Seal Terminations join HDPE to assorted cabinets or meter bases. Quick Seal Terminations incorporate E-Loc or Double E-Loc features to create a weather-resistant seal. PRODUCT DETAILS DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS E-LOC QUICK SEAL TERMINATION FITTINGS HDPE male termination Threaded lock-nut connection No additional tools required Available in 3/4" to 2 1/2" DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS Locking compression HDPE male termination Threaded lock-nut connection No additional tools required Available in 1 1/4" to 2" Weather-Resistant Seal HDPE Threaded Lock-Nut Connection 22
44 CONDUIT ACCESSORIES E-LOC QUICK SEAL TERMINATION FITTINGS REFERENCE DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS DESCRIPTIONS NOMINAL SIZE ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor ETA HDPE terminal adaptor REFERENCE DESCRIPTIONS NOMINAL SIZE DETA Locking compression HDPE terminal adaptor DETA Locking compression HDPE terminal adaptor DETA Locking compression HDPE terminal adaptor TYPE TYPE E-LOC QUICK SEAL TERMINATION FITTINGS & DOUBLE E-LOC QUICK SEAL TERMINATION FITTINGS 23
45 E-LOC TRANSITION FITTINGS & DOUBLE E-LOC TRANSITION FITTINGS APPLICATIONS E-LOC TRANSITION FITTINGS E-Loc and Double E-Loc transition fittings provide a threaded transition between any IPS tapered threaded rigid pipe and HDPE or a male solvent weld transition between PVC and HDPE pipe. One side of the transition fitting is a compression coupling and the other side is either a glued or threaded coupling allowing for a watertight connection of dissimilar material. PRODUCT DETAILS DOUBLE E-LOC TRANSITION FITTINGS E-LOC TRANSITION FITTINGS HDPE to threaded rigid pipe HDPE to solvent welded connection HDPE to PVC Size ranging from 3/4" to 2" No additional tools required for installation Airtight Connections DOUBLE E-LOC TRANSITION FITTINGS Locking compression HDPE to rigid pipe Locking compression HDPE to solvent weld Size ranging from 1 1/4" to 2" No addition tools required for installation Low Profile Excellent Pull-Out Resistance 20
46 CONDUIT ACCESSORIES E-LOC TRANSITION FITTINGS REFERENCE DOUBLE E-LOC TRANSITION FITTINGS DESCRIPTIONS NOMINAL SIZE ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MPT HDPE to any IPS threaded pipe ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end ELA MSW HDPE to PVC standard or bell end REFERENCE DESCRIPTIONS NOMINAL SIZE DEL MPT HDPE to any IPS threaded pipe DEL MPT HDPE to any IPS threaded pipe DEL MPT HDPE to any IPS threaded pipe DEL MSW HDPE to PVC standard or bell end DEL MSW HDPE to PVC standard or bell end DEL MSW HDPE to PVC standard or bell end TYPE TYPE E-LOC TRANSITION FITTINGS & DOUBLE E-LOC TRANSITION FITTINGS 21
47 DOUBLE E-LOC & DOUBLE E-LOC TRANSITION COUPLINGS APPLICATIONS DOUBLE E-LOC COUPLINGS The Double E-Loc is a locking compression coupling used to join smooth, ribbed, corrugated or Figure 8 High Density Polyethylene (HDPE) conduit. The locking, pressure-tight design makes the Double E-Loc an ideal coupling for pneumatic cable placing applications when air and watertight integrity of the system is imperative. Unmatched pressure ratings, pull-out resistance, no metal parts, and no special tools make the Double E-Loc the preferred coupling. Lock rings specially designed to grip rigid PVC and steel pipe are also available. Double E-Loc Transition Couplings have the same great features as the Double E-Loc Couplings, but provide the ability to connect conduit of different sizes. Lock rings designed to grip PVC and steel allow for a single coupling to transition to both a dissimilar size and dissimilar material. DOUBLE E-LOC TRANSITION COUPLINGS PRODUCT DETAILS Can withstand 200 psi internal pressure Provide pull-out resistance in excess of ASTM standards for HDPE Sizes from 3/4" to 2" available No additional tools required for installation Locking Compression Coupling No Special Tools Required Sizes 3/4" to 2" 18
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
More informationConduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
More informationThe National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables
The National Armored Cable Manufacturers Association Presents Installation Standard for Types AC and MC Cables An ANSI Standard Original document jointly produced by NECA and NACMA as Standard for Installing
More informationCONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
More informationKNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
More informationIndustrial Cable Solutions for Variable Frequency Drives
Industrial Cable Solutions for Variable Frequency Drives Tough challenges call for innovative solutions, and General Cable is your worldwide source for new products and a wide range of industry-leading
More informationSection 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
More informationSECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
More informationBuilding Cables and Wires
Building Cables and Wires 4 Introduction alfanar is equipped with state-of-the-art manufacturing facilities such as latest machineries, instrumentation, quality control and testing laboratory, etc., for
More informationLEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
More informationNetwork Standard Advice No. 1420C 9/6/2011
Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides
More informationInstallation and Application Guide. for 600V Conductors
for 600V Conductors for 600V Conductors Foreward This guide discusses recommended or best practices for installing 600 volt conductors in conduit. The purpose of the guide is to identify those critical
More informationKNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
More informationElectric Engineering Division FIBER CONDUIT RULES AND REGULATIONS
Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...
More informationSECTION 18370 SIGNAL WIRE AND CABLE
SECTION 18370 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for all cable and wire required for signal and signal power system wiring to wayside shelters, junction boxes, and factory
More informationHook-Up and Lead Wire
3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:
More information2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
More informationTHE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER
THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER Ever Wonder Why There s No Copper in the Air? Since the early 1900s, aluminum and aluminum
More informationCarlon Bore-Gard and Boreable Multi-Gard Raceway
Carlon Bore-Gard and Boreable Multi-Gard Raceway Bore-Gard Schedule 40 Bore-Gard Schedule 80 Boreable Multi-Gard Type 40 www.carlonsales.com 231 Bore-Gard Trenchless Raceway Carlon Bore-Gard Trenchless
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationSERVICE ENTRANCE - UNDERGROUND Single & Three Phase 200, & 320/400 Amp
SERVICE ENTRANCE - UNDERGROUND 07-01-15 PAGE 1 OF 6 USE: Arrangement of service equipment to supply electric energy to an underground, outdoor self contained meter installation. LATEST REVISION: PREVIOUS
More informationMESSENGERS FOR AERIAL CABLE
MESSENGERS FOR AERIAL CABLE COPPERWELD - EHS, 30% CONDUCTIVITY MES(size)CUWELD Size O.D. Stranding Breaking Strength Wgt./Mft. MES1/4CUWELD 1/4".242 7 #12 5,783 lbs. 128 MES5/16CUWELD 5/16".306 7 # 10
More informationCTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
More informationUNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT 06387 Phone: 860.774.4812 Fax: 860.774.7330 www.cmcorporation.
UNDERSTANDING UNDERSTANDING NFPA 79 By Ned Lloyd and Mike Levesque NFPA-79 is the electrical standard that has been developed by the National Fire Protection Association (NFPA) and is intended to minimize
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationSTABILOY BRAND FeeDeR SOLuTIONS
STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum
More informationSolar Power Solutions
Solar Power Solutions Wire and Cable Photovoltaic Connectors Combiner Boxes Fuses Grounding Power Connectors Physical Support Products Cable Ties Supply Chain Solutions Products. Technology. Services.
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationSTABILOY BRAND FeeDeR SOLuTIONS
STABILOY BRAND Feeder Solutions DATA CENTER Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
More informationTubing and Accessories
Section 7 Tubing and Accessories Inch Industrial Tubing................................FIT-7-2 Metric Industrial Tubing...............................FIT-7-3 Inch D.O.T. Tubing...................................FIT-7-3
More informationFlexible Spill Containment Protecting You And The Environment
Flexible Protecting You And The Environment Unit Liner Company C o nta i n m ent Syste m s C o nta i n m ent Syste m s Foam Foam Clean and store for repeated use Includes Clean and patch store kit for
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationWIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS
CONDUCTORS Conductors are needed to complete the path for electrical current to flow from the power source to the working devices and back to the power source. Special wiring is needed for battery cables
More informationHOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12
SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications
More informationTown House 11265 Center Highway North Huntingdon, PA 15642
APPENDIX C SPECIFICATIONS FOR THE CONSTRUCTION OF BUILDING LATERAL SANITARY SEWERS DECEMBER 2004, INCLUDING AMENDMENTS ADOPTED ON FEBRUARY 6, 2008 AND APRIL 2, 2008; EFFECTIVE ON MAY 1, 2008 Town House
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationReference:! PRODUCT STANDARDIZATION BULLETIN! for HDPE Duct, Conduit, MicroDuct & Pull Tapes!
Customer Service 800-847-7661 Winner of Verizon s Supplier Excellence Award Rated Tops in Product Performance Product Support On time Delivery Customer Satisfaction Reference: PRODUCT STANDARDIZATION BULLETIN
More informationSTABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES
STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES Introduction General Cable understands that assisted living facilities require complex building designs that must address a wide range of systems
More informationSECTION 260513 MEDIUM VOLTAGE CABLE
SECTION 260513 MEDIUM VOLTAGE CABLE PART 1 - GENERAL 1.1 SUMMARY A. Related Documents: 1. Drawings and general provisions of the Subcontract apply to this Section. 2. Review these documents for coordination
More informationpvc well casing & drop pipe
CertainTeed pvc well casing & drop pipe PVC Well Products Sure Fit PVC well casing and drop pipe have gained broad acceptance since their introduction almost 40 years ago. Today, due to its outstanding
More informationCorporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationNative InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness
More informationThe Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe
The Most Advanced Name in Drainage Systems Sanitary Sewer Pipe SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling,
More information4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
More informationW-2. Stranding Comparison
Wire Knowledge W-1 W-2 Stranding Comparison Conductor Coatings/Coverings PURPOSE To facilitate stripping of components applied over the conductor To prevent compound fall-in Improve solderability Prevent
More informationTABLE OF CONTENTS. PUD SERVICE TERRITORY & CONTACTS... Page 1. NEW SERVICE QUESTIONNAIRE... Page 2. GENERAL... Page 3
UNDERGROUND TABLE OF CONTENTS PUD SERVICE TERRITORY & CONTACTS... Page 1 NEW SERVICE QUESTIONNAIRE... Page 2 GENERAL... Page 3 TRENCHING SECONDARY (120/240 volts)... Page 3 CONDUITS FOR PUD-INSTALLED CONDUCTORS...
More informationGAS INSTALLERS MANUAL CINERGY AND SUBSIDIARY COMPANIES CUSTOMER PROCEDURE FOR INSTALLING 3", 4", 6", AND 8" IPS PLASTIC GAS SERVICE PIPING
CINERGY AND SUBSIDIARY COMPANIES CUSTOMER PROCEDURE FOR INSTALLING 3", 4", 6", AND 8" IMPORTANT TELEPHONE NUMBERS IPS PLASTIC GAS SERVICE PIPING Cinergy Gas & Electric Services For information regarding
More informationHIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
More information450-750 VOLTS - Copper conductor PVC insulated SSA 1320, IEC 60227 & BS 6004 HO 7V - U With Solid Conductor - TYPE 60227 IEC 01. Insulation Thickness
450 50 VOLTS Copper conductor PVC insulated SSA 320, IEC 6022 & BS 6004 HO V U With Solid TYPE 6022 IEC 0 For internal wiring equipment rated voltage up to 000 V AC and up to 50 V to earth. Catalogue Number
More informationThe Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
More informationHeating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
More informationCOMMERCIAL CONDUIT RULES AND REGULATION
Electric Engineering Division COMMERCIAL CONDUIT RULES AND REGULATION S:\COO_ACM_US_Electric_Telecommunications\COO_ET_Engineering\Conduit Policies\Residential 1805 NE 30th Ave., Bldg. 400 Ocala, FL 34470-4875
More information505.3.6 For a building with a crawl space, see Figure 10. 505-1
505 WATER SERVICE INSTALLATION 505.1 DEFINITION A service line is comprised of the piping and related appurtenances including the connection installed from the Des Moines Water Works water main to the
More informationSECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
More informationCarlon Carflex Liquidtight Flexible Tubing
Carlon Carflex Liquidtight Flexible Tubing Carflex Carflex X-Flex Fittings Cord Grips Pre-Wired Whips www.carlon.com 3 Carflex Liquidtight Flexible Conduit Carflex Liquidtight Flexible Nonmetallic Conduit
More informationOFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO.
OFFICE OF CIVIL ENGINEERING UNITED STATES COAST GUARD WASHINGTON, D.C. APRIL 1996 MARINE CABLE, POWER AND CONTROL SPECIFICATION NO. G-SEC-390E 1. SCOPE 1.1 Purpose. This specification establishes the basic
More information3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.
The following shall serve as the minimum requirements for contractors performing work in relation to the Authority s potable water and sanitary sewer system(s), appurtenances and service connections. General:
More informationApplication Data Important Safety Information
Application Data Important Safety Information Read this page before using any of the information in this catalog. This catalog is designed to be used as a guide in selecting the proper hose for the applications
More informationMaxCell Technical Manual Design Parameters
MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50
More informationGAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationFoam Injection Molding:
Foam Injection Molding: Unique Process Solutions for Light Weighting Automotive Plastic Parts Steve Braig President & CEO Trexel, Inc. AGENDA Technology Overview > Chemical Foaming > Physical Foaming Foamed
More information2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.
More information3200 West 22nd Street Erie, PA 16506 ph 814.835.2900 fax 814.835.2904 www.premierconduit.com
200 West 22nd Street Erie, PA 16506 ph 814.85.2900 fax 814.85.2904 www.premierconduit.com Premier-Plenum Duct Premier Plenum Duct is a flexible, non-metallic, corrugated raceway used for effective interior
More informationUnderground Service Requirements and Instructions
This packet includes all FKEC underground service requirements, instructions, procedures and drawings. If you are considering underground power service please review this document in its entirety (3 page
More information18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30
Commercial Products COMMERCIAL PRODUCTS: RIGID AND IMC FITTINGS s Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels,
More informationIRRIGATION PUMPING Table of Contents - Section 900
IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS
More informationVoltage Loss Formula s
www.litz-wire.com HM Wire International Inc. Phone: 330-244-8501 Fax: 330-244-8561 Voltage Loss Formula s www.hmwire.com Voltage loss in a wire is synonymous to pressure loss in a pipe. Electric current
More informationLeast Cost Cable System. Strategies to Reduce Cable and Infrastructure Costs When Transitioning to an All Conduit Systems
Least Cost Cable System Strategies to Reduce Cable and Infrastructure Costs When Transitioning to an All Conduit Systems Cost Sharing of Cable Systems Underground Extensions The Company will construct
More informationTERMINATION ENCLOSURE OPTIONS
TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated
More informationCable Installation Notes
Cable Installation Notes June 2006 Table of Contents Cable Pulling... 2 Bending Radius... 2 Pulling Tension... 3 Friction... 3 Installation with Rollers... 4 Installation without Rollers... 4 Pulling Tension
More informationCABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
More informationMANUFACTURER S CERTIFICATE OF COMPLIANCE
s Type AC (Armored Clad) aluminum and steel interlocked metal clad 600-volt cable is produced 100% in the United States of America using accepted practices and quality assurance procedures to comply with
More informationRESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:
RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS: Signed completed Electrical Permit application form. Minnesota law requires all electrical work is to be performed by licensed,
More informationC O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
More informationAT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding
AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding A Guide for California Developers of Com m ercial Property This guide consists of
More informationSTREETLIGHT SYSTEM GROUNDING AND BONDING
Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial
More informationEcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoFlex cable is Alpha Wire s newest innovation in control cabling. A true engineering breakthrough, EcoFlex
More informationElectrical Safety Products
Electrical Safety Products Trelleborg Electrical Safety Products A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount. Trelleborg
More informationEast Central College 14434.03 HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE
SECTION 260519 - BUILDING WIRE AND CABLE PART 1 - GENERAL 1.1 WORK INCLUDES A. Base and Alternate Bids: 1. Contractor Provide: a. Building wire and cable as shown on drawings or specified including feeders,
More informationProtection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
More informationThe MC Cable Revolution is Gaining Ground REMKE
The MC Cable Revolution is Gaining Ground June 2014 MC Cable Installation Continues to Improve with Advances in Materials and Fittings As the use of Metal Clad Cable grows, contractors are demanding better
More informationTELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities
1 TELUS Residential Service Conduit Requirements for Stand Alone Homes and Duplexes in Fibre Only Communities Beginning in January 2010 TELUS began designing new subdivisions within the Top 48 population
More informationCable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks
Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt
More informationType XHHW-2 or RHH/RHW-2/USE-2 GenFree II LSZH XLPO Single Conductor
TABLE OF CONTENTS SECTION I. SUBJECT SCOPE 2 II. APPLICABLE DOCUMENTS 2 III. CONDUCTOR 3 IV. SEPARATOR 3 V. INSULATION 3 A. 3-4 B. Electrical Properties 4 C. Flame Resistance 5 D. Smoke and Halogen Testing
More informationShort Circuit Current Calculations
Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationUptown Campus, Primary Electric Master Plan - Program Study State University of New York At Albany, SUCF Project No. 01832 V.
V. DESIGN STANDARDS i. Medium Voltage Cables ii. iii. iv. Separable Connectors Splices & Fault Indicators Manholes & Ductbanks Primary Switches & Medium Voltage Transformers v. Metering, Monitoring, &
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationNEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps
NEW SERVICE INSTALLATION STEPS Here is the step-by-step process required to fulfill your service installation request. Please take a few minutes to review the steps, become familiar with key milestones
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationPROTECH ELECTRICAL CONNECTORS AND CABLE TIES
INDEX ALLIGATOR CLIPS... 7-7 compressor lead sets... 7-7 CONNECTORS BUTT... 7-3 closed... 7-3 ELECTRICAL... 7-2 terminal adapters... 7-2 QUICK CONNECTS... 7-5 7-6 TWIST-ON WIRE... 7-2 HEAT SHRINK TUBING
More informationDouble Coated Urethane Foam Tapes
3 Double Coated Urethane Foam Tapes 4004 4008 4016 4026 4032 4052 4056 4085 Technical Data April, 2009 Product Description 3M Double Coated Urethane Foam Tapes are conformable foams that offer high shear
More informationCable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection
Cable Guide Cables, Connectors & Tools for installation of quality networks TRIAX - your ultimate connection A Selection of the best Triax TX Cable range optimised for digital reception Simplification
More informationELECTRICAL: WIRE, CABLE, AND TERMINATIONS
ELECTRICAL: WIRE, CABLE, AND TERMINATIONS BASIS OF DESIGN This section applies to the design and installation of wire and cable systems and terminations. Design Criteria Medium Voltage Review and modify
More informationSECTION 603 SANITARY SEWER FORCE MAINS
SECTION 603 SANITARY SEWER FORCE MAINS 1. GENERAL Pipelines for sanitary sewer force main systems shall conform to the following specifications and shall be installed at the locations indicated on the
More information