GTP-32 Control Processor. Overview Operation Web Pages Built-in Diagnostics Event Logs Troubleshooting
|
|
|
- Elmer Parrish
- 10 years ago
- Views:
Transcription
1 GTP-32 Control Processor Overview Operation Web Pages Built-in Diagnostics Event Logs Troubleshooting
2 GTP-32 Control Processor The GTP-32 Control Processor is a member of the Flex Control Network product line
3 FLEX CONTROL NETWORK Control any Device From any Location Share Tally & Status between any Locations Over LAN / WAN / Internet
4 FLEX CONTROL NETWORK Used for Production Control VTRs DDRs Video Server Channels Graphic Playout Devices Remote Location Device Controller Serial Ethernet Serial Ethernet GPI Serial Ethernet LAN / WAN Intranet Internet GPI Serial Ethernet Production Switcher Newsroom Computer System Control Panel Shotbox
5 FLEX CONTROL NETWORK Used in Master Control Automation Backup USP-16 Emergency Bypass / Live Insert Control LAN WAN Internet
6 Flex Control Network FLEX CONTROL NETWORK Agile Master Control USP-16: Select NET to monitor / control GTP-32: Route sources to monitor wall Select monitor wall layout Map sources to virtual monitors PKM App: Terminate currently running Automation client Launch selected NET s Automation client
7 FLEX CONTROL NETWORK Used for On-Air Tally Control Facility Router Area Router VideoServer 1 VideoServer 2 Video Sources CAMERA 1 Router System CAMERA 2 Router System Video Output Video Inputs Video Converter #1 Serial / Ethernet Video Converter #2 Serial / Ethernet PRODUCTION SWITCHER Serial / Ethernet Serial / Ethernet Router(s) Device Controller Switcher & Multi-viewer Device Controller
8 GTP-32 Control Processor Overview Operation Web Pages Built-in Diagnostics Event Logs Troubleshooting
9 FLEX CONTROL NETWORK GTP-32 CONTROL PROCESSOR Supports: 32- GPI 32- GPO 4 Serial Ports Hardware: GTP-32 = DC21 GTP-32 DC20 DC20 has no GPI or GPO 2 Ethernet Ports
10 GTP-32 Control Processor Assign a Source Event to control an Action SOURCE EVENT ACTION
11 GTP-32 Control Processor Assign one Source Event to control many Actions 1 EVENT MANY ACTIONS
12 GTP-32 Control Processor Share Source Events across GTPs Action Tally Source Event Utah Router
13 Configuration Tip: GTP-32 Control Processor Configure the GTP that performs the Action Action Tally GTP #1 GTP #2 GTP #3 Configure GTP #2 to monitor Source Event on GTP #3. When Source Event turns ON, local Tally turns ON. Utah Router Source Event
14 GTP-32 Control Processor Each GTP has its own: CPU (Brain) Configuration Web Server
15 GTP-32 Control Processor Event Monitoring Web Page Source Event Action
16 GTP-32 Control Processor Event Monitoring Web Page Source Event Action
17 GTP-32 Control Processor Source Event Action: How it Works Source Event turns ON Execute ON Function Source Event turns OFF Execute OFF Function More than one Source Event controls the same ON action: Any Source Event can execute the ON action (Logical OR) More than one Source Event controls the same OFF action: All Source Events must be OFF to execute OFF action (Logical AND)
18 GTP-32 Control Processor Configuration Web Pages Display Status Event Monitoring Web Page Source Event OFF= Green ON= Red GPO Action OFF= Green ON= Red NOTE- Momentary GPIs and GPOs always display OFF
19 GTP-32 Control Processor Source Event Processing The GTP-32 processes a Source Event (i.e: GPI) only when it changes state. Changes from ON to OFF, or OFF to ON A Change of State Notification tells the GTP that a Source Event has changed state. Turned off or turned ON The GTP requests (registers for) Change Of State Notifications for all of the Source Events entered into its Event Monitor Table The GTP registers for both local Source Events and for Source Events on a remote GTP-32 Registration requests and responses are event logged Registration requests only occur for local Source Events immediately after GTP power up Registration requests only occur for remote GTPs when a successful connection is made, or re-established, to the remote GTP
20 CONDITIONAL CONTROL using Combinatorial Events More than ON or OFF GTP-32 Control Processor Considers multiple inputs before choosing ON or OFF, or allowing a change to be made Provides a simple way to disable control when it is not needed and enable it when it is needed Creates more than one possible action based upon operator key press and system status Create simple logic statements in Combinatorial Event Definition Table. Supports OR, AND, NOT logic
21 GTP-32 Control Processor Overview Operation Web Pages Built-in Diagnostics Event Logs Troubleshooting
22 Web Pages GTP-32 Control Processor Create Source Events and Actions Assign Device Protocols to control channels, serial or Ethernet For USP Display Source Event or Action status on USP LCD keys Configure channel to control Utah router
23 GTP-32 Control Processor Create Actions Create Source Events For Troubleshooting
24 Diagnostics GTP-32 Control Processor
25 GTP-32 Control Processor View any configuration web page at any time. No login required Login is required to make any changes Login is always require for the System link
26 GTP-32 Control Processor Source Event Creation Rules Every Source Event must have a unique label on the GTP-32. A label may exist on more than one GTP-32. The IP Address + label makes it unique A Source Event Label may be added at any time No reboot is required The Source Event definition may be changed at any time No reboot is required If a Source Event Label is modified, the original label will be deleted and replaced with the new label. You must change the label wherever it is used to match the new label. No reboot is required
27 Action Creation Rules GTP-32 Control Processor Every Action must have a unique label on the GTP-32. A label may exist on more than one GTP-32. The IP Address + label makes it unique An Action Label may be added at any time No reboot is required An Action definition may be changed at any time No reboot is required If an Action Label is modified, the original label will be deleted and replaced with the new label. You must change the label in on Event Monitoring web page. No reboot is required
28 GTP-32 Control Processor BACKUP / RESTORE Configurations Every Configuration Web Page has a Backup and Restore link at the top of its page Backup saves the web page s configuration to a file on the GTP-32 Many Backup files can reside on the GTP-32 To copy file to PC: Right mouse click on file name Select Save Link As or Save Target As Navigate to directory
29 GTP-32 Control Processor BACKUP / RESTORE Configurations Restore copies the configuration from file to the web page Select file on GTP-32 by clicking on radio button Click on Load button At prompt Do you really want to load this.?, click on Load To copy file from PC To GTP: Click on Browse button Navigate to directory and select file Click on Upload to GTP-32 button
30 GTP-32 Control Processor GTP-32 To GTP-32 Configuration
31 GTP-32 Control Processor Overview Operation Web Pages Built-in Diagnostics Event Logs Troubleshooting
32 GTP-32 Control Processor Built-in Diagnostics: GPO Control Control individual GPOs. Turn on/off Virtual GPI Generation Turn a GPI on/off to test local or remote Event Monitoring Table entry Combinatorial Diagnostic View the current state of each source event used in a Combinatorial Event Definition
33 GTP-32 Control Processor Overview Operation Web Pages Built-in Diagnostics Event Logs Troubleshooting
34 Event Logs GTP-32 Control Processor Automatically generated for every Source Event and Action change of state 7 one-day logs. 8 th day overwrites oldest log 8 12 files per day. 2MB per file Files are only overwritten as they are used Simple, comma delimited, ASCII text files Copy Event Log file to PC: Right mouse click on file name Select Save Link As or Save Target As Navigate to directory
35 Event Logs Source Events are event logged only if: GTP-32 Control Processor Used directly in the Event Monitoring Table on the local or a remote GTP Used in a Combinatorial Event Defintion that is used in the Event Monitoring Table on the local or remote GTP All Actions are logged
36 Event Logs GTP-32 Control Processor Event Log entry: "SYS:05/18/ :07:19:00","LTC:02:57:34:27"," ","IOD: GPI_3(L)","M_TAKE","OFF "SYS:05/18/ :07:19:00","LTC:02:57:34:27"," LTC Input Connector on rear of GTP-32 GTP s Internal Real-time Clock Date and Time Internal Tick Count Increments every 16ms Reset to 0 at powerup
37 Event Log entry: Event Logs GTP-32 Control Processor "SYS:05/18/ :07:19:00","LTC:02:57:34:27"," ","IOD: GPI_3(L)","M_TAKE","OFF "IOD: GPI_3(L)","M_TAKE","OFF Internal Process Name Source Event or Action Label IOD= GPI / GPO/ Key Press Processing EPS= Source Event Processing for Event Monitoring Table and remotely monitored events DMP= Event Monitoring ON/OFF Function processing CHx= Protocol Assignment Table channel Current State ON / OFF
38 Event Logs GTP-32 Control Processor Channel #1 Event Log entry: "SYS:02/10/ :55:36:00","LTC:00:00:00:00"," ","CH:1 UTAH Auto- Notification: Level 1, Dest. 274, Saved Src = 506, New Src = 84" Router Destination# Source# Router Status Update
39 Event Logs GTP-32 Control Processor GPI turn ON detected Typical Sequence: "SYS:05/18/ :07:49:00","LTC:02:58:04:20"," ","IOD: GPI_3(L)", "M_TAKE", "ON "SYS:05/18/ :07:49:00","LTC:02:58:04:20"," ","EPS-T: Event Received: M_TAKE from Local State:ON Source Event processed "SYS:05/18/ :07:49:00","LTC:02:58:04:20"," ","EPS: Event M_TAKE notification sent to 1 registrant(s) "SYS:05/18/ :07:49:00","LTC:02:58:04:20"," ","DMP: EVENT", "M_TAKE", "ON EMT ON Function Processed "SYS:05/18/ :07:49:00","LTC:02:58:04:20"," ","DMP: ON ACTION","Turn On GPO","Data:27"
40 Event Logs GTP-32 Control Processor Typical Sequence: "SYS:02/09/ :02:21:00","LTC:17:57:36:19","205817","EPS-T: Event Received: CH_1_HD3 from State:OFF Source Event received from remote GTP "SYS:02/09/ :02:21:00","LTC:17:57:36:19","205817","EPS: Event Received: TV3CR1B from Local State:OFF Source Event processed "SYS:02/09/ :02:21:00","LTC:17:57:36:19","205817","EPS: Event TV3CR1B notification sent to 2 registrant(s)" "SYS:02/09/ :02:21:00","LTC:17:57:36:19","205817","DMP: EVENT", "TV3CR1B", "OFF" EMT OFF Function Processed "SYS:02/09/ :02:21:00","LTC:17:57:36:19","205817","DMP: OFF ACTION","Turn Off GPO","Data:1" "SYS:02/09/ :02:21:00","LTC:17:57:36:19","205818","IOD: ACTION GPO_1 OFF","GPO_1","Turn GPO OFF" GPO Action executed
41 Event Logs GTP-32 Control Processor "SYS:03/08/ :28:45:00","LTC:07:30:09:11"," ","REMOTE DEVICE is ONLINE GTP has connected to remote GTP "SYS:03/08/ :40:21:00","LTC:07:41:46:00"," ","REMOTE DEVICE is OFFLINE GTP lost connection to remote GTP "SYS:03/08/ :42:23:00","LTC:07:43:48:01"," ","REMOTE DEVICE is ONLINE" GTP re-gained connection to remote GTP NOTE: Continual loss and gain of connection between GTPs indicates a network issue
42 Event Logs GTP-32 Control Processor Near the top of each file: "SYS:05/18/ :07:19:00","LTC:02:57:34:20"," ","New log , Filename: /ata0/webs/eventlog/elog-fri-0.txt." IP Address File name and path "SYS:05/18/ :07:19:00","LTC:02:57:34:20"," ","Model: GTP-32; DC30; Serial No: ; Version: 6.50; Label: APN_BREAK_MAIN;" Model Serial Number Software Version User entered Label
43 Event Logs GTP-32 Control Processor Periodically throughout file: Memory Usage Stats "SYS:05/18/ :07:19:00","LTC:02:57:34:20"," ","MemStats: Free= Alloc= FrBlocks=1043 maxfrblock= FD-Use:20/128" For DNF use only "SYS:02/10/ :09:34:00","LTC:00:00:00:00"," ","Total number of dropped log messages: 1191" Number should not increment during normal operation after power-up completes System Logging Activity
44 GTP-32 Control Processor Overview Operation Web Pages Built-in Diagnostics Event Logs Troubleshooting
45 Troubleshooting On the Event Monitoring Table web page For the entry that is not working Is the Source Event and Action entered in the EMT? Does the STATUS column show Enabled? GTP-32 Control Processor Does the CONNECTION column show Local or Remote? Does the EVENT STATUS column show OFF or ON? If the CONNECTION column shows Offline, the GTP cannot connect to the remote GTP. Check the remote IP address. If the EVENT STATUS column shows Pending or Error, check the spelling of the Source Event Label and that it exists. For a remote Source Event, check that the Source Event exists on the remote GTP.
46 Using the Event Logs: Troubleshooting GTP-32 Control Processor Does the Source Event appear in the Event Log during the time of interest? If not, check the Source Event. NOTE- If the Source Event is not used in the EMT or by a remote GTP, it will not be logged. After receipt of the Source Event, does the log show a DMP Event or DMP Action after it? If not, check the EMT ON/OFF Function entries. Does the log show Remote Device OFFLINE for remote GTP? Check the entered IP address for the remote GTP. Check the remote GTP. The log will show "EPS: Event [source label] notification sent to x registrant(s) where x is the number of users registered for the source event. The user may be a remote GTP or the local EMT.
47 Troubleshooting Device control and monitoring On the Protocol Assignment Table web page GTP-32 Control Processor Check the STATUS column on the far right. Does it show Connected? If not, check the connection between the GTP and device. Also, check the configuration of the device. Is the correct protocol name shown in the CONTROL PROTOCOL column? If not, check the PHY Config and DEVICE Config settings in the Protocol Assignment Table.
48 Troubleshooting When contacting DNF Controls for assistance: GTP-32 Control Processor Provide a short description of the problem. Include the Action or Source Event that did not work (if known), and the approximate time that the problem occurred (if known). Send a copy of the Event Logs for the day or days in question. If possible, please compress the log files prior to sending them. If the problem involves multiple GTPs, send Event Logs from each of the GTPs. After reviewing the submitted log files, DNF Controls may request additional information regarding GTP configuration and operation. DNF will provide detailed, written instructions on how to collect the requested information.