CT 1000 PSTN SPEECH DIALLER ENGLISH DESCRIPTION TECHNICAL MANUAL

Size: px
Start display at page:

Download "CT 1000 PSTN SPEECH DIALLER ENGLISH DESCRIPTION TECHNICAL MANUAL"

Transcription

1 PSTN SPEECH DIALLER EN Grade 2 PD6662 Grade 2 Environmental Class 2 CT 1000 TECHNICAL MANUAL ENGLISH DESCRIPTION CT 1000 is a PSTN speech dialler that is able to send SPEECH and CONTACT-ID digital protocol. The device can be completely remote controlled by voice prompt that guides the user step by step throughout all the operation to be done. The system can be programmed through the integrated keypad or by PC software. Further the normal PSTN speech dialler functions, it s possible to use it like vocal memorandum, alarm clock, or like answering service. It s provided by a multiuser menù that allows to arm and disarm the device, visualize all the events, reset the call cycle, change all the telephone numbers, listen and record local or remote messages, activate and deactivate controls through some codes., besides being a dialler, can be used like a small alarm control unit. It can manage: - 8 user codes, - snapshot and delayed inputs, - 24 hours inputs, - programmable as sirens outputs, - complete events menu, - speech and CONTACT ID digital protocol. The main features are: 4 lines programmable as inputs or outputs, 8 programmable telephone numbers for vocal notification, 8 programmable telephone numbers for Contact ID notification, 1 status input used to check a remote device s state, 1 input programmable as call local reset.

2 index DESCRIPTION... KEYPAD TECHNICAL MENU KEYPAD TECHNICAL MENU KEYPAD USER MENU... 3 SPEECH MENU... 4 COVER OPENING AND FIXING... 5 BOARD DESCRIPTION - CONNECTIONS... 6 FIRST ACTIVATION AND DEFAULT RESET... 6 LED FUNCTIONS... 6 DIALLER DESCRIPTION... 7 ENTER PROGRAMMING AND FUNCTIONS KEYS... 7 ENTER PROGRAMMING AND LOGIN IN THE MENU... 7 MENU TELEPHONE NUMBERS... 8 SET UP THE TELEPHONE NUMBERS... 8 MENU VOCAL CALLS... 9 MENU PLAY/RECORD... 9 LINK PHONE NRS... 9 CALL MEANTIME... 9 SECONDS BEFORE ANSWER... 9 ATTEMPTS NUMBER... 9 MESSAGE REPETITION NUMBER MESSAGE CONFIRM TIME MENU ZONES/OUTPUTS LINE TYPE INPUT TYPE STATUS INPUT INPUT TEST OUTPUT TYPE OUTPUT TEST PULSE TIME OUTPUTS OUTPUT PULSE PULSE REPETITION MENU CODES HANDLING TECHNICIAN CODE CALL RESET USER CODE USER MODE MENU PARAMETERS INPUT TIME OUTPUT TIME ACTIVATE TAMPER LIFE TEST DELAY ANSWER RINGS NUMBER REMOTE MESSAGE ENABLED ENABLE RING SKIP DTMF DURATION DTMF INTERVAL LINE TONE TEST LINE PRESENCE TEST DISPLAY INTENSITY AND CONTRAST... 15

3 TIMER CORRECTION MONITOR ENABLED SUMMER TIME ENABLED BEEP ENABLED ACTIVATION BUZZER TIME MENU CONTACT ID MENU IDC EVENTS MENU IDC NUMBERS IDC TEL NUMBERS MAX TRIALS NUMBER INPUT RESTORE NOTIFICATION LINK TELEPHONE NUMBERS DATE & TIME MENU EVENTS PARAMETERS RESET CALLS AND MANAGEMENT WITH THE VOCAL MENU RECEPTION OF A VOCAL CALL USER MENU SYSTEM ACTIVATION AND DEACTIVATION OUTPUT STOP ANSWERING SERVICE ALARM CLOCK AUTOMATIC INPUT EXCLUSION CALL TO THE DIALLER USER VOCAL MENU TECHNICAL SPECIFICATION... 21

4 KEYPAD TECHNICAL MENU - 1 Technician code DEFAULT Name: Telephone number Tel number 01 Tel. number: Options: A = answer confirmation B = direct access to user menù C = automatic call cycle reset Vocal calls Speech Messages Play/Record MO1:Header 0:Play 1:Rec 2:Erase Speech Messages Link phone nrs. M02:Tamper 0:PLAY Call meantime [010] Seconds before answer [030] Attempts number [002] Message repetition number [002] Zones/Outputs Message confirm time sec [15] Line Type Input Type Input Test Output Type Output Test U= output C= in NC O= in NO B= in balanced A= instant call D= delay call S= 24-hour call R= reset of alarm call cycle I = ON - OFF - = output that can be linked to user codes A= alarm M= memory (follows red LED of keypad) V = 220 absence S = system status T = tamper P = PSTN line absence 1-4= activated by each activation of the correspondent input Pulse time output 1 TECHNICAL CODE Output pulse output 1 CALL RESET Pulse repetition output 1 USER CODE Codes handling USER MODE 01 M 1 M=master =link to outputs

5 KEYPAD TECHNICAL MENU - 2 Contact ID Idc Events Contact ID partition [00] Parameters Idc Numbers Input Time Seconds [015] Idc Tel Number 1 Max trials number [005] Input restore notif. [No ] M02:Tamper M02:Tamper [133] M03:Activation [401] M04:Deactivation [401] M05:AC line Off [301] M06:AC line On [301] M07:PSTN fail [351] M08:Life test [602] M09:Status On [401] M10:Status Off [401] M11:input 1 [000] M12:input 2 [000] M13:input 3 [000] M14:input 4 [000] Output time sec [000] Line tone test [Yes] Automatic input exclusion [No ] Line presence test [Yes] Activate tamper [No ] Display intensity [050] Life test Delay [000] Display contrast [020] Answer rings number [003] Timer Correction sec [000] Remote message Enabled [Yes] Monitor Level [ 0 ] Enable ring skip [000] Summer time enabled [Yes] Dtmf duration msec [100] Activation buzzer time [000] Dtmf interval msec [080] Beep Enabled [Yes] Date & Time Parameters reset Parameters reset confirm Events 2

6 KEYPAD USER MENU Master User Code System activation Output stop Events Local message 0:Play 1:Rec 2:Erase Tel number 01 Name: Remote message 0:Play 1:Rec 2:Erase Remote message Enabled [Yes] Telephone number Alarm clock Enable/disable Alarm clock Tel. number: Options: Alarm clock hour No 00: :Play 1:Rec 2:Erase Delay time between the first signalling and the followings A = answer confirmation B = direct access to user menù C = automatic call cycle reset Date & Time Automatic input exclusion [No ] Speech message menagement Timer Correction sec [000] Display intensity [050] Display contrast [020] 3

7 SPEECH MENU Dial personal code Is Personal Code correct? Personal Code incorrect DIAL 1 to work on the system Dial 1 to arm the system Dial 2 to disarm the system 1= system armed 2 = system disarmed DIAL 2 to change outputs status Select output (# to exit) Dial 1 to enable Dial 2 to disable Dial 3 to enable with pulse DIAL 3 to check system status OUTPUTS STATUS INPUTS STATUS SYSTEM STATUS Dial # to exit 4

8 COVER OPENING AND FIXING Open the keypad housing pushing the flap in the lower part with a screwdriver by keeping the keypad door open (fig.1 point1). Take the posterior part of the keypad and fix it to the wall (the electronic board remains fixed to the anterior part). During the fixation pay attention to the tearing element; if you want to have an anti-tearing protection it is necessary to fix it to the wall with a screw, so as to keep the keypad tamper switch closed. If you don t want to use the anti-tearing protection you have to bend the switch flap, so as to keep it pressed when the housing is closed. Close the case by leaning the anterior part onto the clips of the posterior part. Then push the anterior part of the housing until it clicks and fits together with the posterior part

9 BOARD DESCRIPTION - CONNECTIONS TERMINALS: SUPPLY (+ -) = 13.8Vdc Power Supply INPUTS/OUTPUTS ( ) = alarm inputs or programmable open-collector outputs + - COM = +12V reference for open-collector outputs and 0V reference for inputs STATUS = input dedicated to monitoring status of external devices LINE = connections to the PSTN line PHONE = connections to the local telephones PROG = connector for the PC programming FIRST ACTIVATION AND DEFAULT RESET Make sure that the connections are right. Press CANC key and keep it pressed when giving the power to the system (from 12Vdc to MAX 14Vdc). Wait until the three leds (red - yellow - green) stop blinking at the same time. The dialler is resetted and ready to use. Otherwise it s possible to reset the dialler in the following way: once the dialler is switched on, enter the DEFAULT TECHNICAL CODE (000000) and, whit the vertical arrows, select the Parameters reset menu. Confirm with the return key and repeat the confirmation. After the initialization process the device is ready to be programmed. LED FUNCTIONS The system features 3 LEDs beacons: RED LED = if it s turn on steady it indicates a persistent anomaly, if it blinks it indicates that there is a new event in the menu events, if it s turn off there aren t any problems. YELLOW LED = if it s turn on steady it indicates that there is a new local message, if it blinks slow it indicates that there is a new remote message, if it blinks fast it indicates that there are both local and remote messages. GREEN LED = it indicates the PSTN line status. Led turn on steady = the dialler is keeping busy the telephone line, led turn off = the dialler isn t keeping busy the telephone line, led blinked = it indicates that the dialler is armed. 6

10 DIALLER DESCRIPTION ENTER PROGRAMMING AND FUNCTIONS KEYS Besides the normal PSTN dialler function, the can be used like an answering service, like a vocal memorandum or like an alarm clock. Moreover, with the 8 user codes, it can be used to activate any electric or electronic device connected to it. Actually, for each code, it s possible to link an OC output; this output can be activated and deactivated, both in local and in remote, knowing the device status by audio support. can send Ademco CONTACT ID digital protocols, that can be setted up for any input and for any event; can be used like a small control unit. In fact, every input can be snapshot, delayed or 24 hours. It s possible to link an output to the inputs for use it for a siren. The dialler has 2 menu: the first, for the user, is accessible with the user code (default ); the second is the technical menu (default ). The user menu allows: - Arm and disarm the dialler, - read the event menu, - listen, record or erase a vocal memorandum, - listen, record or erase a message in the answering service, - enable and disable the answering service, - modify the telephone-book, - set the alarm clock, - set the clock, - adjust the intensity and the contrast of the display. With the technical menu it s possible to carry out quit the device programmation. ENTER PROGRAMMING AND LOGIN IN THE MENU Key in the technical code ( default); system is in the technical menu. Use up and down arrows keys to move to the programming steps and modify the parameters values. Press RETURN to modify the menu. Use the alphanumeric keypad to key in alphanumeric strings. Use the CANCEL key to exit the menu or to move to the upper level. Use the # or right arrow to move right in a parameter. Use the or left arrow to erase a value in a menu. Use the vertical arrow keys to increase or decrease a value in a menu. To set the menu default value it s possible to use the following keys: 1 = Minimum value 2 = Default value 3 = Maximum value 7

11 MENU TELEPHONE NUMBERS SET UP THE TELEPHONE NUMBERS This section explains how to define the 8 telephone numbers available for the vocal calls. It s possible to define the telephone number, the name, and the options for each number. - Telephone number: it s the number that will be called for a specific event. - Name: it s the name of the person that will be called. - Options: they are relating only to the selected telephone number. A B C answer confirmation direct access to user menu automatic call cycle reset the system shall receive a DTMF tone # to define a call as successful; if this does not happen the system will call again the same telephone number for a maximum of times equal to the set number of call attempts. the user with this option doesn t dial own user code to enter the user menu. if the call to the telephone number with this option is successful, the entire call cycle will be cancelled. Tel number 01 Telephone number Tel number 08 Name: Tel number: Options: Use the alphanumeric keypad to key in name and number. To move right and left use the horizontal arrow or and # keys. To erase a parameter use the CANC key. To key in the options press any numeric keys (1 time = A, 2 times = B, 3 times = C). 8

12 MENU VOCAL CALLS In this menu there are all the vocal calls setup parameters; messages recordings, telephone numbers linking, number of call attempts, etc. MENU PLAY/RECORD M01:Header 0:Play 1:Rec 2:Erase M12:input 4 0:Play 1:Rec 2:Erase - To select the event use the vertical arrows. - To work to the selected event use the return key. - Press 0 to listen, 1 to record, 2 to erase. LINK PHONE NRS. In this menu it s possible to link the telephone numbers to the events. M02:Tamper 0:PLAY M12:input 4 0:PLAY - Use the vertical arrows to select the event. - To link the telephone numbers press return and check the blinked cursor position; then, with the # key, move to the desired number and, with the vertical arrow keys, link the number. - Press 0 to listen the selected event message. = disable telephone number = able telephone number CALL MEANTIME This parameter is the time (in seconds) that elapses between consecutive calls of the same call cycle (minimum value 005 sec., maximum value 600sec.). To modify the values press return and check that the cursor blinks. Use the vertical arrows to modify. SECONDS BEFORE ANSWER This parameter is the time (in seconds) that the system wait until the call is answered. EX: 30 means that, the telephone called by the dialler, will ring only for 30 seconds. After which the dialler will close the call and it will call the followed number (minimum value 005 sec., maximum value 120 sec.). To modify the values press return and check that the cursor blinks. Use the vertical arrows to modify. ATTEMPTS NUMBER This parameter indicates the number of call attempts to a telephone number when it cannot be reached (minimum value 001, maximum value 008). To modify the values press return and check that the cursor blinks. Use the vertical arrows to modify. 9

13 MESSAGE REPETITION NUMBER This parameter indicates the number of times the message is repeated when a telephone number has been reached (minimum value 001, maximum value 010). To modify the values press return and check that the cursor blinks. Use the vertical arrows to modify. MESSAGE CONFIRM TIME This parameter indicates the time (in seconds) to confirm the reception of a vocal message, when the confirm parameter is enabled. The calculation starts at the same time of the message repetition. (minimum value 015, maximum value 120). To modify the values press return and check that the cursor blinks. Use the vertical arrows to modify. 10

14 MENU ZONES/OUTPUTS In this menu there are all the paremeters concerning the dialler s lines. The lines are the INPUTS - OUTPU- TS terminals. Each line can be setted like an input or like an OC output. On end there is the parameters complete list. LINE TYPE It s possible to program 3 different types of inputs or set OC output: C = normally closed O = normally open B = single EOL resistor U = open collector output To set the parameter press return till the wanted line will blink, and, with the vertical arrow, select the type. Use and # or the horizontal arrows to move from a line to another. INPUT TYPE It s possible to programme an input with several possible functions: A = instantaneous alarm (it works only when the system is armed). D = delayed alarm (it works only when the system is armed). S = 24 hours input, unregarding the status (armed/disarmed) of the system. R = reset of alarm call cycle function. I = system ON / OFF function. To set the parameter press return till the wanted line will blink, and, with the vertical arrow, select the type. Use and # or the horizontal arrows to move from a line to another. NORMALLY CLOSED INPUT (N.C.) NORMALLY OPEN INPUT (N.O.) SINGLE EOL RESISTOR (R1 = 1KΩ) 11

15 STATUS INPUT The status input is used to check the state of a remote device connected to the dialler (ex. control units, airconditioning, etc.). This input is able to do a vocal or digital call quite personalized, according to its state (open or closed). Moreover, in case of remote connection, it s possible to question the dialler, and get a personalized message about the state of the status input and, consequently, the state of the device connected to the dialler. INPUT TEST With this parameter it s possible to check the state (open/close) of the all dialler inputs. Input Test - OUTPUT TYPE = input open = input close - = input not programmed It s possible to programme several output functions: - = output that can be linked to user codes. A = alarm (siren). M = memory (red LED keypad). V = no power supply (it refer to the SUPPLY terminal). S = system status. T = tamper. P = PSTN line absence To set the parameter press return till the wanted line will blink, and, with the vertical arrow, select the type. Use and # or the horizontal arrows to move from a line to another. OUTPUT TEST With this parameter it s possible to check the state (activated/deactivated) of the dialler outputs. Output Test - PULS TIME OUTPUTS = activated output = deactivated output - = output not programmed This parameter sets the duration in seconds of the activation of a pulsed output. The setting can vary from 1 sec. to 255 sec. To modify the parameter press return. The value that you have to modify blinks; use the vertical arrows to set the new OUTPUT PULSE This parameter sets how many times a pulsed output has to activate in case of activation (EX. in case of output programed as siren there are the siren cycle numbers). To modify the parameter press return. The value that you have to modify blinks; use the vertical arrows to set the new PULSE REPETITION This parameter sets the time between two activation cycles of a pulsed output. This time is in seconds and the maximum time is 24h. To modify the parameter press return. The value that you have to modify blinks; use the vertical arrows to set the new Using the 4 key the value is increased with 60, using the 5 key the value is increased with 3600 (1 hour). 12

16 MENU CODES HANDLING In this menu there are all the parameters relative to the use of the all codes available to the dialler (technician code, users codes, reset codes, users settings up). TECHNICIAN CODE The technician code allows to modify all the dialler parameters, so it s advisable the use by qualified people. The default is , and, contrary to the users codes, it isn t possible to reduce the digits number. To modify the parameter press return; when the cursor blinks use the numeric keypad to set up the code. Press CANC to erase. CALL RESET The call reset code is used to stop the call cycle of an alarm. After receiving a call, the user has to press the # key, digit the call reset code, and press again the # key; the call cycle will be resetted. To modify the parameter press return; when the cursor blinks use the numeric keypad to set up the code. Press CANC to erase. USER CODE The dialler can manages at most 8 different codes. The code length can vary from 1 to 6 digits. NOTE: if the code is compound by 6 digits, when the code has been digited the system automatically entry the user menu. If the code is less than 6 digits, after the user digits it, he has to confirm with the return key on the keypad, or with the # key in remote. To modify the parameter press return; when the cursor blinks use the numeric keypad to set up the code. Press CANC to erase. USER MODE This parameter define the code function: M = master. It allows to entry the complete user code (see USER MENU) = input-output linking function. If the output has a time, it will be activated for this time in pulsed mode. If the time is 0, the output is stable (code = activation --> code = deactivation). Note: when an output is activated with a code, the activation is reported on the display. 13

17 MENU PARAMETERS INPUT TIME With this parameter is possible to modify the reaction time of the all inputs programmed with the delayed alarm function (see INPUT TYPE). value (minimum time 000sec., maximum time 255sec.). OUTPUT TIME This delay sets the time between code entering and system arming. If the is used without any control unit, this parameter is used to allow to leave the protected place after the dialler activation (minimum time 000sec., maximum time 255sec.). ACTIVATE TAMPER This parameter enables the anti-opening tamper switch. LIFE TEST DELAY This parameter sets how often the system has to notify a life test signal. The value can vary from 000 hours to 240 hours. ANSWER RINGS NUMBER This parameter sets the number of rings that the system waits before answer. REMOTE MESSAGE ENABLED With this parameter it s possible to enable the answering service (see USER MENU). ENABLE RING SKIP The ring skip is used when the dialler is installed on a telephone line shared with answering services, FAX devices, etc.. Example: the connected fax device answers after 4 rings, the dialler is setted with 8 answer rings. To communicate with the dialler you have to do 2 rings, close the call, wait for 5-10 sec. and recall. This time the dialler precede the fax answer. The ENABLE RING SKIP define how many rings you have to do to activate this function. 14

18 DTMF DURATION With this parameter it s possible to modify the length of the telephone number composition tone (DTMF). The default value is that used for normal installation. If the dialler has to be installed on telephone lines that can have problems on the DTMF reception, it s possible to extend the length of each number during the composition. (default value = 80msec., maximum value 120msec.). DTMF INTERVAL This parameter fix the pause between a DTMF tone and the following. In case of problems it s possible to slow down or increase the composition speed. (default value = 80ms, maximum value 120ms). LINE TONE TEST It s possible to enable or disable the line tone control (440Hz). In case of problems it s possible to disable the tone control and leave active the line presence control (see the following parameter). LINE PRESENCE TEST The line presence test carry out only the line voltage control on the dialler terminals. In case of problems it s possible to disable it. Note: if you disable the line presence test the dialler doesn t notify the telephone line failure DISPLAY INTENSITY AND CONTRAST It s possible to set up the display intensity and contrast relatively to the installation site. TIMER CORRECTION If the clock isn t precise, it s possible to correct it with this parameter. The correction has to be done taking into consideration the error that the clock has in a month. For example, if the clock is 25 fast in a month, it s possible to deduct them setting up in this parameter the value -25. MONITOR ENABLED It s possible to enable the internal dialler loudspeaker so as to have the vocal support of the user operations (system activation and deactivation, outputs activation and deactivation, etc.). The possible values are 3: 0 = monitor disabled, 1 = system and outputs activation and deactivation messages, 2 = complete monitor activation. (It s possible to hear the telephone numbers composition and the messages reproduction). Note: the value 2 is useful to diagnose telephone lines problems. 15

19 SUMMER TIME ENABLED It s possible to enable the automatic change to the summer time (last March sunday and last October sunday). BEEP ENABLED It s possible to enable or disable the keys sound. ACTIVATION BUZZER TIME When this parameter is enabled, if the system is armed, it emits a cadenced bip. The time, in this parameter, is the interval between a bip and another. The value can vary from 0 (disabled) and 300 (maximum). 16

20 MENU CONTACT ID The dialler is able to send CONTACT ID digital protocols. This protocols are completely changeable and programmable, both the events and all the inputs. MENU IDC EVENTS The IDC events are the codes that the system sends; those already definite are default. It s possible to freely modify any codes. Default codes list: Tamper = 133 Main power ON / OFF = 301 PSTN error = 351 Life test = 602 Status ON / OFF = 401 Inputs = 000 Contact ID partition = 00 MENU IDC NUMBERS In this menu it s possible to set up the 8 available numbers, the system identification code and assign the numbers to the events, with other characteristics. IDC TEL NUMBERS It s possible to set up 8 telephone numbers with 8 different ID. Idc Numbers Idc Tel Number 1 Idc Tel Number 8 Use the keypad to insert the number and the ID. Use the horizontal arrow keys or the and # keys to move left and right. Use the CANC key to erase a parameter. MAX TRIALS NUMBER ADEMCO ID: Tel. number: This parameter indicates the call attempts number in case of receiver unreachable (minimum value 001, maximum value 008). 17

21 INPUT RESTORE NOTIFICATION It s possible to send the inputs restore notification. LINK TELEPHONE NUMBERS With the following menu it s possible to link the telephone numbers with the events. M02:Tamper 0: PLAY M12:input 4 0: PLAY - Use the vertical arrows keys to select the event. - To link the number press return; when the cursor blinks, use the # and keys to move to the wanted number, and, with the vertical arrows keys, link the number. - Press 0 to listen the recording of the select event. 18

22 DATE & TIME To set date and time: - press return and, when the cursor blinks, use the vertical arrows keys to modify the parameter. - use and # keys or the horizontal arrows keys to move horizontally. MENU EVENTS The dialler is supply with about 250 events memory. To visualize it select menu events and press return. With the vertical arrows keys you can choose one of them and, pressing return, visualize its details. PARAMETERS RESET See FIRST ACTIVATION AND DEFAULT RESET paragraph. CALLS AND MANAGEMENT WITH THE VOCAL MENU RECEPTION OF A VOCAL CALL While receiving a vocal call from the dialler it s possible to perform several operations, depending on the programming (options) linked to the call number: NUMBER WITHOUT ANY OPTIONS: once the call has been answered, the dispatch is considered successful, therefore the dialler will call the following number. In case the user wants to enter the user menu, enter #, dial the personal call, and then press # again. STOP A CALL WITH THE RESET CODE: once a call has been answered, PRESS # TO STOP THE MESSAGE AND DIAL THE RESET CODE (example #123#); the system will respond with the message call cycle stopped. NUMBER WITH OPTION A (ANSWER CONFIRMATION): in order to make the call to the number successful it s necessary to press #; if this is not done the system will call immediately the same number. In case the user wants to enter user menu, he/she has to enter # and then dial the personal code. NUMBER WITH OPTION B (DIRECT ACCESS TO USER MENU): when the call is answered, after the message repetition, the system switches immediately to the user menu without asking the personal code. By pressing # the access will be anticipated. NUMBER WITH OPTION C (RESET OF THE CALL CYCLE): when the call is considered successful, the system will reset automatically the remaining calls. Important: when this option is activated, it s useful to activate option A as well, to be sure that the entire call cycle can be reset only by pressing #. NOTE: the above mentioned options can be entered for each telephone number; at each telephone number several options can be assigned. 19

23 USER MENU SYSTEM ACTIVATION AND DEACTIVATION In the inputs programming it s possible to select the instantaneous alarm function (type A), or 24 hours input function (type S) for each input. Using this type of inputs, it s possible to arm or disarm the dialler like an alarm control unit. When the dialler is disarm, only the calls relative to the inputs programmed with the S function will be done. In this case will not be done the calls relative to the input programmed with the A function. This kind of calls will be done only when the dialler is armed. To arm the dialler is necessary to dial a code of a user with M function (master); on the keypad display will immedialtely appear the written System activation. Press return to confirm the activation. If there are opened inputs, the system notifies them. In this case it s possible to exclude them or enable the system and close this inputs during the output time. To disarm, dial the user code. NOTE: if the monitor is enabled, the dialler provides the system status with the vocal support. OUTPUT STOP This parameter is used to stop all the outputs that are steady and permanent activated and that haven t a deactivated event (ex. output programed with infinite cycles activation). ANSWERING SERVICE The dialler is supplied with a local and a remote answering service. The local answering service is an audio memorandum that can be recorded in the dialler with a master code. The dialler will indicate the presence of a message with the yellow led lighting. To listen the message dial the user code and, with the vertical arrows keys, select Local message ( 0 = listening, 1 = recording, 2 = message erasing). The remote message is a traditional answering service. To record a message with a remote telephone it s necessary to listen the vocal guide that will invite to press key to record the message. The user can listen the message in remote or in local. To listen the message in remote the user has to refer to the dialler vocal guide. In local, instead, when there is a message in the answering service, the yellow led of the keypad blinks. The user can listen the message dialling the user code and selecting, with the vertical arrows keys, REMOTE MESSAGE ( 0 = listening, 1 = recording, 2 = message erasing). ALARM CLOCK The dialler is also supplied with an alarm clock. In the user menu select the alarm clock menu, press return and, with the vertical and horizontal arrows keys, set all the parameters for the activation of the alarm clock (see the following figure). Note: if there is no message recorded, the system will use a BIP to signal the alarm clock. alarm clock activation alarm clock setting up repetition of the alarm clock signalling (in minutes) AUTOMATIC INPUT EXCLUSION With this parameter it s possible to exclude all the opened inputs in case of remote armed (by telephone or by ON - OFF input). CALL TO THE DIALLER If the answer is enabled, after the set number of rings, the system will accept the incoming call asking the user code. After this code introduction, if the code is correct, the user will be introduced to the user vocal menu. USER VOCAL MENU Yes 06: :Play 1Rec. 2:Erase The vocal menu can only be entered by calling the system, or when you are called by the system; it s not intended to programme, but only for remote operating by user. Look at SPEECH MENU. 20

24 Meets the requirements: EN Grade 2 PD6662 Grade 2 Environmental Class 2 Our products/systems comply with the essential requirements of EEC directives. Installation must be carried out following the local installation norms by qualified personnel. AMC Elettronica S.r.l. refuses any responsibility when changes or unauthorized repairs are made to the product/system. It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and due to, but not limited to, any or all of the following: tampering, electrical or communication disruption or improper use, it is possible for the product/system to fail to prevent burglary, robbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk that this happens. 21

Automatic Telephone Dialer TD-101(W)

Automatic Telephone Dialer TD-101(W) Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages

More information

C24-GSM ALARM CONTROL UNIT (24 INPUTS) WITH INTEGRATED GSM COMMUNICATOR ENGLISH DESCRIPTION USER MANUAL

C24-GSM ALARM CONTROL UNIT (24 INPUTS) WITH INTEGRATED GSM COMMUNICATOR ENGLISH DESCRIPTION USER MANUAL C24-GSM ALARM CONTROL UNIT (24 INPUTS) WITH INTEGRATED GSM COMMUNICATOR USER MANUAL ENGLISH DESCRIPTION C24 GSM is an alarm control unit with 24 inputs and integrated GSM communicator, which uses the existing

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-5587722 +972-3-5500442 [email protected] http://www.pima-alarms.com

More information

User s Information Guide R1A

User s Information Guide R1A HSC505-R Home Security Controller - User Manual Release R1a Pi HSC505 and Pi HSC505R Home Security Controller User s Information Guide R1A Page 1 QD Dynamics (Pty) Ltd reserves the right to make changes

More information

Microprocessor Home Security System

Microprocessor Home Security System numbers of sensor s activations in the zone and after which activations the zone will be discarded (ignored). On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a

More information

PowerWave-8. Users Operating and Programming Guide Version 8.64. 8 zone Control panel Communicator

PowerWave-8. Users Operating and Programming Guide Version 8.64. 8 zone Control panel Communicator ELECTRONIC ENGINEERING LTD. PowerWave-8 8 zone Control panel Communicator Users Operating and Programming Guide Version 8.64 P/N 7101261 Rev. C N.A July 2002 2 Contents Introduction...5 Meet the Crow Alarm

More information

VOCALISER USER INSTRUCTIONS. Pyronix Ltd OCTOBER 2000. RINS113 Issue 2

VOCALISER USER INSTRUCTIONS. Pyronix Ltd OCTOBER 2000. RINS113 Issue 2 VOCALISER USER INSTRUCTIONS Pyronix Ltd OCTOBER 2000 RINS113 Issue 2 9 RECEIVING A CALL FROM THE VOCALISER A telephone call from the Vocaliser is easily recognised by the distinctive three tones heard

More information

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL Manufacturer: Viatron Electronics 3514 1st Street, St-Hubert (Quebec) Canada J3Y 8Y5 WARNING: the warranty can be void if the Agri-Alert 800T or

More information

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128

Manufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Dallas Delta Corporation Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Email: [email protected] www.dallasdelta.com.au LP GUARD DOORSTATION MK II G UARD Doorstation

More information

CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com

CAPTAIN 6. USER GUIDE System ver. 6.0. 6 Zones Intruder Alarm System. PIMA Electronic Systems Ltd. www.pima-alarms.com CAPTAIN 6 6 Zones Intruder Alarm System USER GUIDE System ver. 6.0 PIMA Electronic Systems Ltd. www.pima-alarms.com P/N 4410049, G2 XX en, Jan. 2010 2 CAPTAIN 6 User Guide SAFETY INSTRUCTIONS Your CAPTAIN-i

More information

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual SUPA8 Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS... 1 INSTALLATION OF THE SECURITY SYSTEM... 2 COMMISSIONING THE DIALLER PANEL... 5 ZONE INPUT CONNECTIONS... 7 PANEL

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT CONTENTS Page INTRODUCTION... 2 Security conditions... 3 Full Set (Fully armed)... 3 Part Set (Partially armed)... 3 Unset (Disarmed)...

More information

Solution-16 Operators Manual ISSUE 1.60

Solution-16 Operators Manual ISSUE 1.60 Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided

More information

Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office

Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office Cerber C612 12-Zone and 2-Partition Burglary Control Panel For your home and office Doc 10905/ 09.2005/ version 2.0 User s Guide 1. INTRODUCTION...4 General Features...4 User Codes...4 Installer Codes...5

More information

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear. SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types

More information

PK5500 v1.1 Installation Instructions

PK5500 v1.1 Installation Instructions PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on

More information

MICROPROCESSOR HOME - SECURITY SYSTEM Home4

MICROPROCESSOR HOME - SECURITY SYSTEM Home4 MICROPROCESSOR HOME - SECURITY SYSTEM Home4 The system is useful for protection of small buildings - living places, shops, offices, store places etc. including up to 8 separate zones. It has built-in power

More information

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand Elite 8D/Lite Version 8 Zone Controller 8 Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand 2 CONTENTS Page No. INTRODUCTION 4 About your Alarm 4 OPERATING

More information

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS USER MANUAL USER MANUAL ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS INTRODUCTION The (HA-841K) is a complete

More information

GSM-DL2 GSM auto dialer

GSM-DL2 GSM auto dialer Introduction GSM-DL2 GSM auto dialer GSM-DL2 is a GSM auto dialer; designed for car alarm, boat alarm, home alarm and other applications. When it is triggered, it dials pre-programmed telephone numbers

More information

SPECIAL CONTROL BUTTON FUNCTIONS

SPECIAL CONTROL BUTTON FUNCTIONS Operating Guide 1 2 3 CONTENTS Page No. OPERATING YOUR ALARM 5 General Information 5 Arming the Alarm 5 Disarming the Alarm 6 Arming in Stay Mode 7 Disarming Stay Mode 8 Bypassing Zones 8 Manual Panic,

More information

616, 626, 636 & 646 Keypads

616, 626, 636 & 646 Keypads 616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15

More information

TABLE OF CONTENTS FEATURES

TABLE OF CONTENTS FEATURES TABLE OF CONTENTS FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2 PC1500RK Keypad... 2

More information

ACE AUTODIALLER MANUAL FOR LIFT COMPANY

ACE AUTODIALLER MANUAL FOR LIFT COMPANY ACE AUTODIALLER MANUAL FOR LIFT COMPANY 1 2 Information to the Building Owner. In June 2003 the harmonised standard BSEN81-28 came into effect. The standard states that it is the building owners responsibility

More information

2 Session buttons. 1 Phone Screen

2 Session buttons. 1 Phone Screen 1 Phone Screen 2 Session buttons Shows information about your phone, including directory number (extension), call information (for example caller ID, icons for an active call or call on hold) and available

More information

Wireless Home Security System Product Manual (Model #80355)

Wireless Home Security System Product Manual (Model #80355) Wireless Home Security System Product Manual (Model #80355) Installation Instructions During set-up, if no key is pressed for 15 seconds it will come out of the setup mode and you will have to start over.

More information

Magellan All-in-one Wireless Security System

Magellan All-in-one Wireless Security System Magellan All-in-one Wireless Security System MG6250 Console Version 1.0 Menu Programming Guide Introduction The MG6250 All-in-one Wireless Console is a two-partition, 64-zone wireless console, offering

More information

ABUS WIRELESS ALARM SYSTEM

ABUS WIRELESS ALARM SYSTEM ABUS WIRELESS ALARM SYSTEM These installation instructions are published by Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affing/Mühlhausen. All rights including translation reserved. Reproductions

More information

Solution 16 plus. User Guide Security System

Solution 16 plus. User Guide Security System Solution 16 plus EN Security System Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch ). All rights are reserved.you may download

More information

SCORPION Z16040C Alarm Controller User Instructions

SCORPION Z16040C Alarm Controller User Instructions SCORPION Z16040C Alarm Controller User Instructions Thank you for choosing to purchase this micron security alarm controller. Micron product is manufactured to exacting quality standards. We understand

More information

User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd

User Manual GSM Alarm System. www.deltasecurity.cn. All rights reserved by Delta Security Co., Ltd User Manual GSM Alarm System All rights reserved by Delta Security Co., Ltd Dear Clients, Thank you for using our GSM Alarm System. We are committed to giving you the best home security available today

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

CA60 Plus Software Version 3.1 User Manual May 2000

CA60 Plus Software Version 3.1 User Manual May 2000 TeleT eletek ek CA60 Plus Software Version 3.1 User Manual May 2000 CONTENTS 1. CA60Plus Keypad... 3 1.1. LED display... 3 1.2. Keys... 4 1.3. Combinations of Keys... 4 1.4. Audible Indication... 4 2.

More information

How To Program An Autodialer

How To Program An Autodialer GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

Ademco Vista-20P/First Alert FA-168C Basic Commands

Ademco Vista-20P/First Alert FA-168C Basic Commands Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel,

More information

SCORPION. micron security products

SCORPION. micron security products SCORPION 4120 6020 & 8020 USER INSTRUCTIONS Thank you for purchasing a Quality Micron Security Alarm Controller. Micron product is manufactured to exacting quality standards. We understand the importance

More information

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.:

A.1. a Division of Pittway Corporation. Documento: M-010.1-MGAS-ENG. Edizione: 01/1997 Rev.: Documento: M-010.1-MGAS-ENG Edizione: 01/1997 Rev.: A.1 a Division of Pittway Corporation FRONT PANEL & VISUAL INDICATIONS GENERAL TROUBLE GENERAL PROGRAMMING IN PROGRESS ENABLE/ALARM/TROUBLE (ZONE 1 ALARM

More information

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

GSM AD05 Slave GSM Auto Dialer- Instruction Manual GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second

More information

Destiny 4100. Destiny 4100. Owners Manual

Destiny 4100. Destiny 4100. Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

IMPORTANT See last page for changes from VERSION 1.2. To enter programming, press [ENTER] + installer code (Installer default code 747474)

IMPORTANT See last page for changes from VERSION 1.2. To enter programming, press [ENTER] + installer code (Installer default code 747474) SOFTWARE VERSION 1.3 IMPTANT See last page for changes from VERSION 1.2 To enter programming, press [ENTER] + installer code (Installer default code 747474) ADDRESSES: addresses "000" to "255" ( key [10]

More information

Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com

Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :

More information

DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE. Ref. 1722/71 USER HANDBOOK

DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE. Ref. 1722/71 USER HANDBOOK Mod. 1722 DS 1722-010B LBT 8546 SINGLE-FAMILY HANDS-FREE COLOUR VIDEO KIT WITH VIDEO DOOR PHONE ANSWERING SERVICE Ref. 1722/71 USER HANDBOOK The CD supplied contains the handbook full version with traslation

More information

Auto Dialer. Manual E-921APQ E-921GPQ

Auto Dialer. Manual E-921APQ E-921GPQ Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL PINKERTON Quick Setup & User Manual QUICK SETUP & INSTALLATION CONTENTS FACTORY DEFAULTS...1 INSTALLATION OF THE SECURITY SYSTEM...2 COMMISSIONING

More information

Using your LED Plus keypad

Using your LED Plus keypad Using your LED Plus keypad System 238 System 2316 System 238i System 2316i Part Number 5-051-372-00 Rev B Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced

More information

astec Integrated Alarm System USER GUIDE

astec Integrated Alarm System USER GUIDE astec Integrated Alarm System USER GUIDE 020008599 CONTENTS Full Set, Part Set and Disarm 3 Instant Full Set 3 Part Set with exit time 4 Bell Test 4 Bypassing zones 4 Switch Lights on/off 4 Bypass (24

More information

Program Entry Guide. Control Panels

Program Entry Guide. Control Panels EN Program Entry Guide Control Panels D6412/D4412 Program Entry Guide EN 2 Documentation Conventions Type Styles Used in this Manual To help identify important items in the text, the following type styles

More information

ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL. User s Guide. Version 9.08.2

ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL. User s Guide. Version 9.08.2 ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL User s Guide Version 9.08.2 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship

More information

SAMSUNG HANDSET USER GUIDE FOR DS-5007S / DS-5014S / DS-5038S / DS-5014D / DS-5021D ITP-5107 / ITP-5114D / ITP5121D

SAMSUNG HANDSET USER GUIDE FOR DS-5007S / DS-5014S / DS-5038S / DS-5014D / DS-5021D ITP-5107 / ITP-5114D / ITP5121D SAMSUNG HANDSET USER GUIDE FOR DS-5007S / DS-5014S / DS-5038S / DS-5014D / DS-5021D ITP-5107 / ITP-5114D / ITP5121D FOR TECHNICAL TIPS PLEASE VISIT OUR WEBSITE www.prptelecom.co.uk 2 Table of Contents

More information

Broadview Networks Business Voice Mail

Broadview Networks Business Voice Mail Broadview Networks Business Voice Mail Welcome to Broadview Networks Voice Mail Service. Our service will allow you to stay in touch when you are either unable or choose not to answer your phone. This

More information

Solution 862 Operators Manual. Issue 1.00

Solution 862 Operators Manual. Issue 1.00 Solution 862 Operators Manual Issue 1.00 Solution 862 Operators Manual Copyright 1998 by Electronics Design and Manufacturing Pty Limited, SYDNEY, AUSTRALIA Document Part Number MA406O Document Issue

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

Using Advanced Phone Features

Using Advanced Phone Features Using Advanced Phone Features This chapter describes how to configure advanced features on your IP Phone. It contains the following sections: Configuring Privacy and Security, page 9 Enabling and Using

More information

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting USER S MANUAL Part 2 2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting Please also read Part 1 Important Product Information AT&T and the globe symbol are registered

More information

IDS X-Series User Manual 700-398-01D Issued July 2012

IDS X-Series User Manual 700-398-01D Issued July 2012 1 2 Contents 1. Introduction to the IDS X-Series Panels... 7 2. Before Operating Your Alarm System... 7 3. Understanding the Keypad LEDs... 8 3.1 Viewing Data on an LED Keypad... 12 3.1.1 LED Status Indicators...

More information

AA9604 Auto Attendant

AA9604 Auto Attendant AA9604 Auto Attendant Operation Manual 10AA96V4M.2.13.EN1 DSG, DSG logo, AA9604, VL880, VL880L, IM1200, IM2400, IL1000 and IL5000 are trademarks of DSG Technology. Windows and Outlook Express are trademarks

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE

POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE POWER POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL MNO PQR STU VWX MNO PQR STU VWX YZ COMMAND YZ COMMAND ABC DEF GHI JKL MNO PQR STU VWX COMMAND YZ USER'S GUIDE Security Command User's Guide for 9XR Command

More information

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400 I. GENERAL G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400 The GAL-6400 Hands Free Emergency Telephone permits a pre-programmed number to be dialed when the "push to call" button is depressed on the

More information

ELECTRONIC ENGINEERING LTD. PowerWave-16. 16 zone Control panel Communicator. User s Operating and Programming Guide. Version: 6.

ELECTRONIC ENGINEERING LTD. PowerWave-16. 16 zone Control panel Communicator. User s Operating and Programming Guide. Version: 6. ELECTRONIC ENGINEERING LTD. PowerWave-16 16 zone Control panel Communicator User s Operating and Programming Guide Version: 6.28 P/N 7121240 Rev c N.A May 2003 Contents Introduction... 4 Meet the Crow

More information

Wightman s. Home Phone. Quick Reference Guide

Wightman s. Home Phone. Quick Reference Guide Wightman s Home Phone Quick Reference Guide Welcome to Wightman Telecom! We would like to thank you for making the decision to join Wightman Telecom as one of our valued customers. Our goal is to prove

More information

Application Notes. 1.21 Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.

Application Notes. 1.21 Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4. Application Notes 1.21 Partition Programming (PC1616/1832/1864 V4.2) Panels: POWER SERIES (PC1616/1832/1864 V4.2) Overview: The PC1616 supports 2 true partitions. The PC1832 supports 4 true partitions.

More information

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel +972-3-6506444 +972-3-5500442 [email protected] http://www.pima-alarms.com

More information

APR-PRT3 Printer Module: C-Bus Programming Instructions

APR-PRT3 Printer Module: C-Bus Programming Instructions APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us

More information

VOICE DIALER MODULE V1.10

VOICE DIALER MODULE V1.10 VOICE DIALER MODULE V1.10 SECURITY HAS A VOICE REFERENCE AND INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION... 3 1.1 SYSTEM FEATURES... 3 1.2 TECHNICAL SPECIFICATIONS... 4 1.3 GLOSSARY OF TERMS...

More information

Dialog 4220 Lite/Dialog 4222 Office

Dialog 4220 Lite/Dialog 4222 Office Dialog 4220 Lite/Dialog 4222 Office System telephones for MD110 Communication System User Guide Flinders University Table of Contents Description 2 Incoming Calls... 10 Outgoing Calls... 12 During Calls

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

ICP-CC488. Installation Guide ICP-CC488 Control Panel

ICP-CC488. Installation Guide ICP-CC488 Control Panel ICP-CC488 EN Installation Guide ICP-CC488 Control Panel ICP-CC488 Installation Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems,

More information

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES "Chime" Digit 1 "Partial Arm" Digit 2 "Quick Arm" Digit 3 ENTRY / EXIT DELAY TIMES Exit Delay Time Entry Delay Time Secondary

More information

Solution 880 Operators Manual ISSUE 1.10

Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual ISSUE 1.10 Solution 880 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA408O DOCUMENT ISSUE 1.10 Printed 25 May 2001 This documentation is provided

More information

WITURA CORPORATION SDN BHD

WITURA CORPORATION SDN BHD WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:

More information

tattletale User Guide Consumer unit version 2.48 1 P a g e

tattletale User Guide Consumer unit version 2.48 1 P a g e tattletale User Guide Consumer unit version 2.48 1 P a g e Contents Basic 1... 4 Base Unit Features... 4 Initial Setup... 4 Arming... 5 Disarming... 5 Quiet Button... 5 Settings... 5 Settings 2... 6 Quick

More information

ADEMCO LYNXR-I Security Systems

ADEMCO LYNXR-I Security Systems K14117 3/06 Rev. A ADEMCO LYNXR-I Security Systems Quick Start Guide UL LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA)

More information

Vision Security System OWNER MANUAL V-LCD1

Vision Security System OWNER MANUAL V-LCD1 Vision Security System OWNER MANUAL V-LCD1 Congratulations on your purchase of the OPTEX Vision security system. Vision is an advanced microprocessor based alarm system which provides fire and burglar

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

AD-01 Slave Auto Dialer. Owner s Manual

AD-01 Slave Auto Dialer. Owner s Manual AD-01 Slave Auto Dialer Owner s Manual AD-01 Slave Manual.indd 1 10/15/2009 10:20:44 AM 2 AD-01 Slave Manual.indd 2 10/15/2009 10:20:44 AM Features: Programmable entry/exit delay time; select up to 9 (32

More information

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM

INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM INSTRUCTION MANUAL All-In-One GSM Home Alarm System SB-SP7200-GSM Revised: August 28, 2014 PRODUCT REFERENCE MOUNTING ACCESSORIES PIR / MOTION DETECTION UNIT MAIN UNIT POWER ADAPTER MOUNTING ACCESSORIES

More information

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 INHEP DIGITAL IDS S E C U R I T Y Users Guide to Keypad Functions MANUAL NO. 700-171-01B ISSUED AUG 2002 VERSION 1.18 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Away Arm Stay

More information

DERYtelecom telephony guide

DERYtelecom telephony guide 1 2 Table of contents Introduction Support Services Customer service Technical support 611 Message relay centre for the deaf Operator service 0 Emergency services 911 Directory assistance service 411 Phone

More information

Installation and Programming Guide

Installation and Programming Guide Speech Dialler Installation and Programming Guide Contents Introduction... 1 Overview... 1 Specifications... 4 Installation... 5 Installation Requirements... 5 Mounting Instructions... 5 PCB Layout...

More information

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction

UM0272 User manual. Central Unit for Alarm System (CUAS) Evaluation Board. Introduction User manual Central Unit for Alarm System (CUAS) Evaluation Board Introduction The Central Unit for Alarm System (CUAS) Evaluation Board provides a complete reference system addressing the low- to middle-end

More information

NGT Hosted Digital Voice. User Guide

NGT Hosted Digital Voice. User Guide NGT Hosted Digital Voice User Guide December 2009 Getting Started Making Calls Using Your NGT Hosted Digital Voice service Domestic Dial as you normally would. You can also reference your local telephone

More information

SmartLink-G, SmartLink-GP GSM Dialler. Programming Manual PATENT PENDING

SmartLink-G, SmartLink-GP GSM Dialler. Programming Manual PATENT PENDING 0470 SmartLink-G, SmartLink-GP GSM Dialler Programming Manual PATENT PENDING Copyright The information contained in this document is the sole property of Inim Electronics s.r.l. No part may be copied without

More information

SD2. Speech Dialler. Installation and Operator s Manual

SD2. Speech Dialler. Installation and Operator s Manual SD2 Speech Dialler Installation and Operator s Manual CONTENTS OVERVIEW... 3 MAIN FEATURES... 4 SD2 LAYOUT... 7 INSTALLATION REQUIREMENTS... 8 PCB LAYOUT... 8 CONNECTIONS TO THE CONTROL PANEL... 9 CONTROL

More information

VISTA-50P VISTA-50PUL

VISTA-50P VISTA-50PUL S e c u r i t y S y s t e m User's Manual VISTA-50P VISTA-50PUL N5943-6 7/95 TABLE OF CONTENTS SYSTEM OVERVIEW... 3 A Partitioned System... 3 Zones... 3 Fire Protection... 4 Burglary Protection... 4 Alarms...

More information

SD1+ Speech Dialler. Installation and Programming Guide. Programming

SD1+ Speech Dialler. Installation and Programming Guide. Programming Speech Dialler Cooper Security Ltd Security House Vantage Point Business Village Mitcheldean Gloucestershire GL17 0SZ www.coopersecurity.co.uk Product Support (UK) Tel: +44 (0) 1594 541979. Available between:

More information

SmartLink-G, SmartLink-GP GSM Dialler. Programming Manual PATENT PENDING

SmartLink-G, SmartLink-GP GSM Dialler. Programming Manual PATENT PENDING 0470 SmartLink-G, SmartLink-GP GSM Dialler Programming Manual PATENT PENDING Copyright The information contained in this document is the sole property of INIM Electronics s.r.l. No part may be copied without

More information

Speech Dialler Engineering Information

Speech Dialler Engineering Information Speech Dialler Engineering Information Description The ADE Informa is a Speech Dialler for use with intruder alarm systems. When the control panel recognises an alarm it will trigger the Informa. The Informa

More information

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc. SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection

More information

Using Your. Security System With Icon Keypad S5020, S5021, S5022

Using Your. Security System With Icon Keypad S5020, S5021, S5022 Using Your Security System With Icon Keypad S5020, S5021, S5022 Contents 1 Overview Your Security System... 1 How Your Security System Works... 2 Your System's Programming... 3 Getting Used to Your System...

More information

NX-8 Installation manual Page 1 Date 13/03/04

NX-8 Installation manual Page 1 Date 13/03/04 NetworX NX-8 Installation Manual NX-8 Installation manual Page 1 Date 13/03/04 CONTENTS CONTENTS...2 GENERAL INFORMATION...4 ORDERING INFORMATION...4 FEATURE DEFINITIONS...5 PROGRAMMING THE NX-8 KEYPADS...12

More information

For customers in AL, FL, GA, SC, TN. wowforbusiness.com. Business Services PHONE FEATURES. User Guide BPG.U.1303.O

For customers in AL, FL, GA, SC, TN. wowforbusiness.com. Business Services PHONE FEATURES. User Guide BPG.U.1303.O wowforbusiness.com Business Services PHONE FEATURES User Guide BPG.U.0.O ANONYMOUS CALL REJECTION. It s easy to activate and start blocking anonymous calls. Simply lift the receiver and press *.. When

More information

Always on the Lookout Perfect Protection against Burglary

Always on the Lookout Perfect Protection against Burglary Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on

More information

How To Control A Car Alarm On A Car With A Remote Control System

How To Control A Car Alarm On A Car With A Remote Control System MODEL CA100 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM Black Antenna Wire 6 Pin 6 Pin Mini Connector Valet Switch Blue LED Indicator Blue Wire: (-) 200mA Unlock

More information