OneCommand Manager Application for the Drivers for Linux Release Notes

Size: px
Start display at page:

Download "OneCommand Manager Application for the Drivers for Linux Release Notes"

Transcription

1 OneCommand Manager Application for the Drivers for Linux Release Notes Version: System: SLES 10 SP3 and SP4 (X86, X64 and PPC) SLES 11 SP1 (X86, X64, IA64 and PPC) RH 5.5(X86, X64, IA64 and PPC) RH 5.6 (X86, X64, IA64 and PPC) RH 5.7 (X86, X64, IA64 and PPC) RH 6.0 (X86, X64 and PPC) RHEL 6.1 (X86, X64 and PPC) Date: September 2011 Purpose and Contact Information These release notes describe the new features, resolved known issues and current known issues associated with this OneCommand Manager application version for the Emulex drivers for Linux release. For the latest product documentation, go to If you have questions or require additional information, contact an authorized Emulex technical support representative at (US/Canada toll free), (US/International), or (Europe, Middle East, and Africa). New Features 1. Host grouping display for discovery-tree fabric view. 2. Fabric-centric port selection is included on the Batch Operation dialog box. 3. In the discovery-tree, you can now search with the host name. 4. PCI Express bus speed and bus width information are added to a universal converged network adapter (UCNA) Info tab. 5. Supports diagnostic dumps for OneConnect OCe10102-x UCNAs and OneConnect OCe11102-x UCNAs. 6. Supports IPv6 remote management. 7. Supports OneConnect OCe11102-xT 10GBASE-T UCNAs. 8. New adapter management relative to application programming interfaces (APIs). New adapter management includes the Resource Management Application Programming Interface (RMAPI) library, Common Information Model (CIM) and Simple Network Management Protocol (SNMP). SNMP is supported for network interface card (NIC) and iscsi only. 9. View Vital Product Data (VPD) for NIC-only and iscsi OneConnect OCe1110x UCNAs. You cannot view NIC or iscsi VPD on the OneConnect OCe1010x UCNAs. OneCommand Manager Application for the Drivers for Linux Release Notes 1

2 Resolved Issues 1. When rapidly selecting or deleting iscsi targets from the One Command Manager application Target List box, a parse error message could have occurred. This issue has been corrected. Known Issues 1. For iscsi ports, if you enable the Dynamic Host Configuration Protocol (DHCP) from the Port Information tab s Modify TCP/IP Configuration dialog box and VLAN is already enabled, the following TCP/IP addresses may not be obtained from the DHCP server (remaining ): IP address, subnet mask and gateway address. You may encounter this known issue if your DHCP Server is not VLAN-aware or is not configured for VLAN. Use one of the following workarounds: Use a DHCP Server that is VLAN-aware and properly configured. Follow these steps to disable and enable DHCP and VLAN: a) On the Port Information tab, click Modify. The Modify TCP/IP Configuration dialog box is displayed. b) Clear the VLAN Enabled and DHCP Enabled checkboxes. c) Click OK. The Port Information tab is displayed. d) On the Port Information tab, click Modify. The Modify TCP/IP Configuration dialog box is displayed. e) Check the VLAN Enabled and DHCP Enabled checkboxes. f) Click OK. 2. OneConnect OCe1010x UCNAs are not taken offline. When you start the diagnostic tests, there is the following message: "The test sequence you are about to run will result in taking the selected adapter off line... Click 'OK' to run the test, or 'Cancel to skip it.' However, when you click OK the adapter is NOT taken offline. Unplug the port on the OneConnect OCe1010x UCNA before running the desired diagnostic test. 3. Diffie-Hellman Challenge Handshake Authentication Protocol (DH-CHAP) is not supported on SLES 11 SP1 and RH6 systems. The fcauthd authentication daemon is supported for RH 5.5 and RH 5.7 systems. The fcauthd authentication daemon is not supported for SL11 SP1, RH 5.6 and RH6 systems. 4. OneConnect upgrade path order recommendation. When upgrading UCNA driver and firmware versions, it is best to upgrade both the driver and the firmware without any reboot in between to minimize the possibility of operating with mismatched versions of driver and firmware. OneCommand Manager Application for the Drivers for Linux Release Notes 2

3 5. The NIC driver must be installed to run the OneCommand Manager application on an FCoE adapter. If the OneConnect FCoE adapter is run without the NIC driver installed, many of the management functions are unavailable. The management functions that are unavailable are: 1. Firmware download Active and flash firmware versions Firmware status BIOS version Boot code version All diagnostics including beaconing Transceiver data display Port disable Physical port link status All CEE settings Event log display (CLI only) Diagnostic dumps 6. CLI (hbacmd.exe) path change. Prior to version 5.1, the hbacmd executable file was installed in /usr/sbin/hbanyware directory. For OneCommand Manager version 5.2, this installation directory has been moved to usr/sbin/ocmanager. However, to allow scripts with hard coded paths to the hbacmd executable in the hbanyware directory to continue to run, a copy of the hbacmd executable is still available in the hbanyware directory. 7. Restriction in assigning DCB priorities to priority groups. Although there are eight priority groups to which priorities can be assigned, you are able to assign priorities and bandwidths to only two of the priority groups. To one priority group you must assign the FCoE or iscsi priority and to the other priority group you must assign the other seven (NIC) priorities. Note: If you are using a DCBX enabled switch to configure the priority groups, configure it for only two priority groups to work correctly with the OneConnect adapter. 8. Requirement for unloading or loading Emulex Device Drivers (FC/FCoE, NIC and iscsi). If you load or unload an Emulex device driver for Linux (FC/FCoE, NIC and iscsi) after the machine is rebooted, you must perform the following steps in the following order: 1. Close any open Emulex OneCommand Manager applications. OneCommand Manager Application for the Drivers for Linux Release Notes 3

4 2. Restart OneCommand Manager application daemons. To restart OneCommand Manager application daemons, the daemons must be stopped and started. a) Run the /usr/sbin/ocmanager/stop_ocmanager script. b) Run the /usr/sbin/ocmanager/start_ocmanager script. 3. Run the Emulex OneCommand Manager application GUI and/or the CLI clients applications. 9. If both VLAN and DCBX are disabled, the iscsi priority configured in the CEE tab is not set in the iscsi packets sent out by the port. Enable or disable VLAN from the iscsi Port Info tab in the OneCommand Manager application. 10. DH-CHAP authentication is not supported for OneConnect adapters. There is currently no support for DH-CHAP authentication for OneConnect adapters. The DH-CHAP tab is not displayed by the OneCommand Manager application when an FCoE node of a OneConnect port is selected in the discovery-tree. In the CLI, authentication commands return an error indicating the command is not supported when the OneConnect FCoE port is specified. 11. DH-CHAP authentication is not supported on SLES 11 SP 1 and RH6 systems. The kernel has removed this feature from the FC device driver module layer. 12. Transceiver data is unavailable for OneConnect OCe11102x UCNAs. The transceiver data is not displayed in the OneCommand Manager application or the OneCommand Manager CLI for OneConnect OCe1110x UCNAs. 13. The adapter s WWN may interfere with the OneCommand Manager application s ability to make permanent changes to the adapter s WWN. Some newer adapters (for example, CNAs) on some newer systems employ techniques in the BIOS code at boot time to configure the adapter. This may include the adapter WWN. In such cases, this may interfere with the OneCommand Manager application s ability to make permanent (non-volatile) changes to the adapter s WWN. 14. iscsi InitialR2T is not supported for iscsi OneConnect adapters. Although both the OneCommand Manager application GUI and CLI (hbacmd) clients allow the configuring of the iscsi InitialR2T parameter to yes or no, the adapter does not recognize the setting. The adapter always operates with InitialR2T set to "yes". OneCommand Manager Application for the Drivers for Linux Release Notes 4

5 15. On SLES 11 SP1 and RH6.0 systems, an unavailable in-band remote OneCommand Manager host causes a 30-second window of vulnerability. When an in-band remote OneCommand Manager application host becomes unavailable for any reason (for example, a cable pull or a machine reboot) there is a 30 second window of vulnerability such that FC-CT commands originating from the SL11 SP1 machine to the remote host during this period hang due to a function call that generates an ioctl to the kernel that does not return. The calling process thread is hung. This problem is due to kernel code (new bsg interface) and a kernel fix is in process. This issue has been addressed in the RH6.1 kernel. Inclusion is also expected in SLES 11 SP2. Emulex recommends avoiding use of in-band management for SLES 11 SP1 and RH 6.0 systems. 16. FC-CT commands to the switch that timeout can cause the OneCommand Manager application processes to hang. The OneCommand Manager application uses FC-CT commands to the switch name server to obtain local HBA symbolic name information. FC-CT commands to the switch originating from a SL11 SP1 or RH6.0 machine that time out cause the OneCommand Manager application process sending the FC-CT command to hang. This problem has been found to be located in kernel code (new bsg interface) and a kernel fix is in process. Scenarios that might result in this behavior include disabling a switch port and modifying VLAN configuration either on the switch or on the host machine via the OneCommand Manager application. No workaround at this time. This issue has been addressed in the RH6.1 kernel. Inclusion is also expected in SLES11 SP Messages appear on the terminal during Web-Launch install/uninstall. On Linux SLES11 SP1 systems, when the OneCommand Manager Web-launch feature is installed or uninstalled using wsinstall and wsuninstall scripts respectively, the following messages are displayed to the terminal. insserv: Script jexec is broken: incomplete LSB comment. insserv: missing `Required-Stop:' entry: please add even if empty. These are warning messages that do not affect the operation or installation of the Web-launch feature. They appear on SLES 11 SP1 specific versions of the relevant software (insserv and jexec). The scripts invoke this software via invocation of the standard Linux chkconfig utility typically used for daemon installations. None required. OneCommand Manager Application for the Drivers for Linux Release Notes 5

6 18. On SLES 11 systems, the Open-FCoE RPM package (open-fcoe ) is incompatible with the OneCommand Manager application package and must be removed from the target host machine. The HBA API library that the open-fcoe package installs (libhbalinux.so.1) causes all OneCommand Manager application processes to crash with a segmentation violation. To recover you must reinstall OneCommand Manager application. 19. On RHEL 5.5 systems, the core kit (elxocmcore RPM) and enterprise kit (elxocm RPM) does not install due to a missing Libnl (NetLinks) library. The OneCommand Core RPM requires Libnl. Unlike other supported operating systems, RHEL 5.5 does not install the Libnl package during a default installation. Install the libnl package from the RHEL 5.5 distribution media. 20. On RHEL 5.5 systems, the OneCommand iscsi SNMP daemon does not start. The OneCommand iscsi SNMP daemon does not start if the package that holds the file is not found. s If the OneCommand Manager application is not installed, install the lm_sensors or higher RPM from the Red Hat distribution media. Install the OneCommand Manager application. If the OneCommand Manager application is installed, run the stop_ocmanager script to stop the OneCommand Manager application daemons. Install the lm_sensors or higher RPM from the Red Hat distribution media. Run the start_ocmanager script to start the OneCommand Manager application daemons. 21. On RHEL 5.4 x86 64 and ppc 64 systems, the Red Hat 32-bit and 64-bit libhbaapi RPMs treat /etc/hba.conf as a configuration file. If no application has modified /etc/hba.conf, this file is deleted when the Red Hat libhbaapi RPM is uninstalled. If an application has modified /etc/hba.conf (example: OneCommand Manager application), this file is moved to /etc/hba.conf.rpmsave when the Red Hat libhbaapi RPM is uninstalled. In either case, uninstalling the 32-bit or 64-bit Red Hat libhbaapi RPMs breaks the OneCommand Manager application because it requires Emulex entries in /etc/hba.conf. If the OneCommand Manager application is installed, do not uninstall the Red Hat 32-bit or 64-bit libhaapi RPM. 22. Unloading the NIC driver from the Linux machine causes the OneCommand Manager application to lose connectivity. If you unload the NIC driver from the Linux machine, any OneCommand Manager application (the GUI or the CLI client) running on the machine loses connectivity with the NIC and related configuration data. OneCommand Manager Application for the Drivers for Linux Release Notes 6

7 To recover, you must perform the following steps in the following order: 1. Stop the OneCommand Manager applications and daemons using the stop_ocmanager script. 2. Reload the NIC driver using modprobe. 3. Restart the OneCommand Manager application daemons using the start_ocmanager script. 4. Restart the desired OneCommand Manager application (GUI or CLI client). 23. When MILI and SNMP daemons start, they trigger warning messages within SELinux for certain operations. To avoid SElinux warning messages, disable SELinux. 1. To disable SElinux, open a terminal and enter the following command at prompt: echo 0 > /selinux/enforce 2. To enable SElinux, open a terminal and enter the following command at prompt: echo 1 > /selinux/enforce 24. A permanent driver parameter change fails if the system is rebooted too soon. When you make permanent driver parameter changes via the OneCommand Manager application, the application automatically makes the required entry in the /etc/modprobe.conf or equivalent file. Because the lpfc driver loads so early in the Linux machine boot sequence, the new contents of the /etc/modprobe.conf file must be re-inserted into the Linux system initrd file (via "mkinitrd" utility) for the driver to pick up the new driver parameter value on the next boot. Failure to generate the new initrd file causes the driver to fail to get the new driver parameter value on subsequent driver loads (machine boots). The OneCommand Manager application automatically does this for you (re-creates initrd via mkinit function); however, it can take as long as seconds after the driver parameter is changed for a complete initrd re-build. Thus, if you reboot the machine immediately after the driver parameter change is made, the auto-recreation of the initrd file by the OneCommand Manager application may fail to complete. In these cases, this failure causes the driver to not obtain the new driver parameter value upon subsequent reboots. Wait a minimum of seconds after making the driver parameter change before rebooting the machine. 25. An unaligned access message can appear on the Linux command shell. When running the HBACMD CLI client, the following unaligned access message can appear on the Linux command shell: elxdiscoveryd(24489): unaligned access to 0x f1c, ip=0x20...8fa680 These messages are "informational" only and do not cause any inaccuracies in the OneCommand Manager application configuration or status reporting. These messages are OneCommand Manager Application for the Drivers for Linux Release Notes 7

8 indications that the OneCommand Manager application code execution is sometimes referencing data aligned to four bytes instead of eight and the IA64 architecture issues a page fault to accomplish it (causing a slight performance hit). These messages can be turned off with the prtcl or dmesg Linux commands. 26. Requirement if Data Center Bridging (DCB) settings are connected to a non-dcbx switch. If DCB settings are required when connected to a non-dcbx switch (or a switch with DCBX disabled), DCBX must be disabled on the OneConnect adapter to use the adapter s configured parameters. If DCBX is enabled, DCB PFC and Priority Groups are ignored (the adapter assumes the switch does not support these features) and for FCoE adapters, the FCoE priority (COS) is Newly added LUNs on a storage array may not appear on the host machine Linux operating system or the OneCommand Manager application. Do one of the following: Run the following script from the command shell: /usr/sbin/lpfc/lun_scan all Reboot the host machine after the LUN has been added at the target array. 28. When using IET software, more than 60 iscsi targets may not be discovered. When using the open source iscsi Enterprise Target (IET) software package to present targets to the iscsi initiator, adding target portals that contain greater than 60 targets fails the resulting target discovery operation. This is due to an error in the IET target implementation. 29. Logged in iscsi targets retain login options through reboots. When an iscsi target is discovered by adding target portal, that target takes the target portal s login options. The target portal s login options are taken from the initiator login options. However, you can modify them when adding the target portal. If a target is discovered by isns, it gets its default login options from the initiator login options. Once a target is discovered, its login properties are not changed when the initiator login options are changed. When you log into a target, the login properties used at the time of login are remembered. If you reboot, the logged in targets are logged in again with the remembered login options (i.e. initiator login options are not used). When you remove the targets (and the target portal if that s how they were discovered) and then cause the targets to be rediscovered, the targets login properties are defined once again by how they are discovered as described at the beginning of this known issue. 30. A physical loopback diagnostic test fails if no transceiver is present on a OneConnect OCe1010x UCNA port. OneCommand Manager Application for the Drivers for Linux Release Notes 8

9 Insert a transceiver into the port before you run a physical loopback diagnostic test. 31. A MAC loopback diagnostic test may fail if the cable is plugged into a OneConnect OCe1010x UCNA port. Unplug the port on the OneConnect OCe1010x UCNA before running the MAC loopback diagnostic test. 32. On RHEL 6.0 and RHEL 6.1 systems, the OneCommand Manager application installation may fail as the OCM JRE required the RHEL6 library file: Libstdc++.5.so and that file is not installed by default. Install the compat-libstdc++-33 RPM included in the RHEL 6 distribution. 33. On RHEL 6.0 and RHEL 6.1 systems, an issue exists with the Java Runtime that may result in the inability to run OCManager on a RHEL 6 host. This problem usually occurs on Blade platforms. This issue causes the OneCommand Manager application to crash immediately upon invocation. Use one of the following management methods: Command Line Utility (HBACMD) Manage the problematic RHEL 6 host from a remote host that is running the OneCommand Manager application. Install WebLaunch services on the RHEL6 host, then point a browser on another host to that RHEL 6 host. 34. When you start a diagnostic test on a OneConnect OCe1010x UCNA port, the following message is displayed: "The test sequence you are about to run will result in taking the selected adapter off line... Click 'OK' to run the test, or 'Cancel to skip it.' However, after you click OK, the adapter is not taken offline. Unplug the port on the OneConnect OCe1010x UCNA before running the desired diagnostic test. 35. An end-to-end (ECHO) diagnostic test fails if the corresponding targets are not supported. Check to be sure the connect targets are supported. 36. On a OneConnect OCe1110x UCNA, running tests using the Diagnostics tab may result in an IOCTL error 0x45. None required. This error only appears in the MILI log (not out to the display) and can safely be ignored. OneCommand Manager Application for the Drivers for Linux Release Notes 9

10 37. On an OneConnect OCe1110x UCNA, installing or uninstalling the OneCommand Manager application may result in an IOCTL error 0x45. None required. This error only appears in the MILI log (not out to the display) and can safely be ignored. Technical Tips 1. In the OneCommand Manager application version 5.1, the basic and advanced login options were in different dialog boxes. In the OneCommand Manager application version 5.2, the iscsi Target Discovery tab includes these basic and advanced login options: Manually Add Target Add Portal Target Login Copyright 2011 Emulex. All rights reserved worldwide. This document refers to various companies and products by their trade names. In most, if not all cases, their respective companies claim these designations as trademarks or registered trademarks. This information is provided for reference only. Although this information is believed to be accurate and reliable at the time of publication, Emulex assumes no responsibility for errors or omissions. Emulex reserves the right to make changes or corrections without notice. This report is the property of Emulex and may not be duplicated without permission from the Company. OneCommand Manager Application for the Drivers for Linux Release Notes 10

OneCommand Manager Application for Windows Release Notes

OneCommand Manager Application for Windows Release Notes OneCommand Manager Application for Windows Release Notes Version: 6.2.10.3 System: Windows Server 2008, Windows Server 2008 R2, and Windows Server 2012: x64 versions, Enterprise and Server Core installation

More information

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes Version (Kit): 2.5.25-2 Date: August 2011 Purpose and Contact Information These release notes describe the new features,

More information

Windows Host Utilities 6.0 Installation and Setup Guide

Windows Host Utilities 6.0 Installation and Setup Guide Windows Host Utilities 6.0 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP

More information

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iscsi) for Linux This page is intentionally left blank. Preface This manual briefly explains the operations that need to be performed

More information

Windows Host Utilities 6.0.2 Installation and Setup Guide

Windows Host Utilities 6.0.2 Installation and Setup Guide Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277

More information

Storage System Software

Storage System Software 2 Release Notes Version 6.0 Storage System Console Version 6.0.25.0012 Storage System Software Version 6.0.25.0017 November 2004 Copyright (c) 2004. All rights reserved. Thank you for your interest in

More information

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN A Dell EqualLogic best practices technical white paper Storage Infrastructure and Solutions Engineering Dell Product Group November 2012 2012

More information

Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server

Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server System Storage DS3000 Storage Manager Version 10 Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server System Storage DS3000 Storage Manager Version

More information

End-User troubleshooting guide. Sentinel SuperPro/UltraPro and Sentinel. Hardware Keys

End-User troubleshooting guide. Sentinel SuperPro/UltraPro and Sentinel. Hardware Keys End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys 1 Preface Welcome to Safenet End User Troubleshooting guide! This guide is intended to assist our Distributors,

More information

OneCommand NIC Teaming and VLAN Manager

OneCommand NIC Teaming and VLAN Manager OneCommand NIC Teaming and VLAN Manager Version 2.0.3 for Windows Server 2003 Windows Server 2008 Windows Server 2008 R2 User Manual P005238-01A Rev. A One Network. One Company. Connect with Emulex. Copyright

More information

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions

HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions HP StorageWorks 8Gb Simple SAN Connection Kit quick start instructions Congratulations on your purchase of the 8Gb Simple SAN Connection Kit. This guide provides procedures for installing the kit components,

More information

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev. Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of

More information

End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys

End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys Preface Welcome to Safenet End User Troubleshooting guide! This guide is intended to assist our Distributors, Customers

More information

Emulex Drivers for Windows User Manual FC and FCoE version 2.72.012.001 NIC version 4.2.390.6 iscsi version 4.2.281.0

Emulex Drivers for Windows User Manual FC and FCoE version 2.72.012.001 NIC version 4.2.390.6 iscsi version 4.2.281.0 Emulex Drivers for Windows User Manual FC and FCoE version 2.72.012.001 NIC version 4.2.390.6 iscsi version 4.2.281.0 Emulex Connects Servers, Storage and People 2 Copyright 2012 Emulex. All rights reserved

More information

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server

Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...

More information

vsphere Host Profiles

vsphere Host Profiles ESXi 5.1 vcenter Server 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

Smart Cloud Integration Pack. For System Center Operation Manager. v1.1.0. User's Guide

Smart Cloud Integration Pack. For System Center Operation Manager. v1.1.0. User's Guide Smart Cloud Integration Pack For System Center Operation Manager v1.1.0 User's Guide Table of Contents 1. INTRODUCTION... 6 1.1. Overview... 6 1.2. Feature summary... 7 1.3. Supported Microsoft System

More information

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2) Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2) Hyper-V Manager Hyper-V Server R1, R2 Intelligent Power Protector Main

More information

SNMP Manager User s Manual

SNMP Manager User s Manual SNMP Manager User s Manual Table of Contents 1. Introduction...2 2. SNMP Manager Install, Quick Start and Uninstall...2 2.1. Software Installation...2 2.2. Software Quick Start...2 2.3. Software Uninstall...2

More information

Direct Attached Storage

Direct Attached Storage , page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel

More information

Command Line Interface User Guide for Intel Server Management Software

Command Line Interface User Guide for Intel Server Management Software Command Line Interface User Guide for Intel Server Management Software Legal Information Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel

More information

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner

More information

new Business Online Technical Troubleshooting Guide

new Business Online Technical Troubleshooting Guide new Business Online Technical Troubleshooting Guide TABLE OF CONTENTS How to install Java 1.6 Page 3 How to install Java 1.6 without ActiveX control Page 6 How to uninstall Java Runtime Environment Page

More information

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 - Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors

More information

Emulex Drivers for Windows User Manual FC and FCoE version 2.74.009.001 NIC version 4.4.176.2 iscsi version 4.4.165.0

Emulex Drivers for Windows User Manual FC and FCoE version 2.74.009.001 NIC version 4.4.176.2 iscsi version 4.4.165.0 Emulex Drivers for Windows User Manual FC and FCoE version 2.74.009.001 NIC version 4.4.176.2 iscsi version 4.4.165.0 Emulex Connects Servers, Storage and People 2 Copyright 2012 Emulex. All rights reserved

More information

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive This guide explains how to create and use a Rescue USB flash drive to reinstall and recover the ExtraHop system. When booting

More information

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com CHAPTER: Introduction Microsoft virtual architecture: Hyper-V 6.0 Manager Hyper-V Server (R1 & R2) Hyper-V Manager Hyper-V Server R1, Dell UPS Local Node Manager R2 Main Operating System: 2008Enterprise

More information

ProSafe Plus Switch Utility

ProSafe Plus Switch Utility ProSafe Plus Switch Utility User Guide 350 East Plumeria Drive San Jose, CA 95134 USA September 2010 202-10524-03 v1.0 ProSafe Plus Switch Utility User Guide 2010 NETGEAR, Inc. All rights reserved. No

More information

Honeywell Internet Connection Module

Honeywell Internet Connection Module Honeywell Internet Connection Module Setup Guide Version 1.0 - Page 1 of 18 - ICM Setup Guide Technical Support Setup - Guide Table of Contents Introduction... 3 Network Setup and Configuration... 4 Setting

More information

Practice Fusion API Client Installation Guide for Windows

Practice Fusion API Client Installation Guide for Windows Practice Fusion API Client Installation Guide for Windows Quickly and easily connect your Results Information System with Practice Fusion s Electronic Health Record (EHR) System Table of Contents Introduction

More information

V310 Support Note Version 1.0 November, 2011

V310 Support Note Version 1.0 November, 2011 1 V310 Support Note Version 1.0 November, 2011 2 Index How to Register V310 to Your SIP server... 3 Register Your V310 through Auto-Provision... 4 Phone Book and Firmware Upgrade... 5 Auto Upgrade... 6

More information

The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.

The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000. Emulex HBA Product Evaluation Evaluation report prepared under contract with Emulex Corporation Introduction Emulex Corporation commissioned Demartek to evaluate its 8 Gbps Fibre Channel host bus adapters

More information

User s Manual Network Management Card

User s Manual Network Management Card User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction

More information

CA arcserve Unified Data Protection Agent for Linux

CA arcserve Unified Data Protection Agent for Linux CA arcserve Unified Data Protection Agent for Linux User Guide Version 5.0 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as

More information

Dell PowerVault Modular Disk Storage Manager User s Guide

Dell PowerVault Modular Disk Storage Manager User s Guide Dell PowerVault Modular Disk Storage Manager User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE:

More information

Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters

Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters Emulex OneConnect Ethernet Network Adapters Introduction This document gives an overview of how to

More information

Installing Operating Systems

Installing Operating Systems CHAPTER 6 The unattended operating system installation function helps you install the Microsoft Windows and RedHat Linux operating system families. UCS-SCU has integrated device drivers including RAID

More information

EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1

EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014. Version 1 EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server 2014 Version 1 NEC EXPRESSCLUSTER X 3.x for Windows SQL Server 2014 Quick Start Guide Document Number ECX-MSSQL2014-QSG, Version

More information

CommandCenter Secure Gateway

CommandCenter Secure Gateway CommandCenter Secure Gateway Quick Setup Guide for CC-SG Virtual Appliance and lmadmin License Server Management This Quick Setup Guide explains how to install and configure the CommandCenter Secure Gateway.

More information

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY)

UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY) UBIQUITI BRIDGE CONFIGURATION PROCEDURE (PowerStation & NanoStation Units ONLY) Hardware Installation 1. Initial placement for programming and configuration purposes should be performed in an indoor environment.

More information

Getting Started with RES Automation Manager Agent for Linux

Getting Started with RES Automation Manager Agent for Linux Getting Started with RES Automation Manager Agent for Linux Contents Chapter 1: Introduction 1 Chapter 2: Prerequisites and General Guidelines 2 Chapter 3: Installation 3 3.1 Manual Installation... 3 3.2

More information

Linux Host Utilities 6.1 Installation and Setup Guide

Linux Host Utilities 6.1 Installation and Setup Guide Linux Host Utilities 6.1 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP

More information

HP Insight Diagnostics Online Edition. Featuring Survey Utility and IML Viewer

HP Insight Diagnostics Online Edition. Featuring Survey Utility and IML Viewer Survey Utility HP Industry Standard Servers June 2004 HP Insight Diagnostics Online Edition Technical White Paper Featuring Survey Utility and IML Viewer Table of Contents Abstract Executive Summary 3

More information

Installing Virtual Coordinator (VC) in Linux Systems that use RPM (Red Hat, Fedora, CentOS) Document # 15807A1-103 Date: Aug 06, 2012

Installing Virtual Coordinator (VC) in Linux Systems that use RPM (Red Hat, Fedora, CentOS) Document # 15807A1-103 Date: Aug 06, 2012 Installing Virtual Coordinator (VC) in Linux Systems that use RPM (Red Hat, Fedora, CentOS) Document # 15807A1-103 Date: Aug 06, 2012 1 The person installing the VC is knowledgeable of the Linux file system

More information

[HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX3.0.0.0] 1

[HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX3.0.0.0] 1 [HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX3.0.0.0] 1 How to Recover an infiniti/evolution Modem Software Reference idx 3.0.0.0 (12.0.0.0) Updated: November 17 th 2011 Overview Recovery Procedures

More information

Lab 8.4.2 Configuring Access Policies and DMZ Settings

Lab 8.4.2 Configuring Access Policies and DMZ Settings Lab 8.4.2 Configuring Access Policies and DMZ Settings Objectives Log in to a multi-function device and view security settings. Set up Internet access policies based on IP address and application. Set

More information

Attix5 Pro Server Edition

Attix5 Pro Server Edition Attix5 Pro Server Edition V7.0.3 User Manual for Linux and Unix operating systems Your guide to protecting data with Attix5 Pro Server Edition. Copyright notice and proprietary information All rights reserved.

More information

IBM WebSphere Application Server Version 7.0

IBM WebSphere Application Server Version 7.0 IBM WebSphere Application Server Version 7.0 Centralized Installation Manager for IBM WebSphere Application Server Network Deployment Version 7.0 Note: Before using this information, be sure to read the

More information

Software Installation Guide

Software Installation Guide Software Installation Guide This manual explains how to install the software over a USB or network connection. Network connection is not available for models SP 200/200S/203S/203SF/204SF. Flowchart The

More information

Sentinel Protection Installer Version 7.6.3 (32-bit and 64-bit Windows) ReadMe

Sentinel Protection Installer Version 7.6.3 (32-bit and 64-bit Windows) ReadMe Sentinel Protection Installer Version 7.6.3 (32-bit and 64-bit Windows) ReadMe This ReadMe provides information about Sentinel TM Protection Installer, its installation and few tips on using the related

More information

Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5. Version 1.0

Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5. Version 1.0 Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5 Version 1.0 November 2008 Deploying IBM Lotus Domino on Red Hat Enterprise Linux 5 1801 Varsity Drive Raleigh NC 27606-2072 USA Phone: +1 919 754

More information

Exploring the Remote Access Configuration Utility

Exploring the Remote Access Configuration Utility Exploring the Remote Access Configuration Utility in Ninth-Generation Dell PowerEdge Servers The Remote Access Configuration Utility supports local and remote server management in ninth-generation Dell

More information

Hyper-V Server 2008 Setup and Configuration Tool Guide

Hyper-V Server 2008 Setup and Configuration Tool Guide Hyper-V Server 2008 Setup and Configuration Tool Guide Microsoft Corporation Published: October 2008 Author: Cynthia Nottingham Abstract This guide will help you set up and configure Microsoft Hyper-V

More information

ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT

ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT README.TXT Adaptec Storage Manager (ASM) as of June 3, 2009 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.

More information

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

SANbox Manager Release Notes Version 1.03.28 50208-06 Rev A

SANbox Manager Release Notes Version 1.03.28 50208-06 Rev A SANbox Manager Release Notes Version 1.03.28 50208-06 Rev A This software is licensed by QLogic for use by its customers only. Copyright (c) 2001 QLogic Corporation All rights reserved Version 1.03.28

More information

COGNEX. Cognex Vision Software. GigE Vision Cameras. User s Guide

COGNEX. Cognex Vision Software. GigE Vision Cameras. User s Guide COGNEX Cognex Vision Software GigE Vision Cameras User s Guide June 2008 Cognex Software and GigE Vision Cameras Cognex VisionPro and CVL software provide support for acquiring, processing, and displaying

More information

How to simulate network devices using the Verax SNMP Simulator (Linux/Windows)

How to simulate network devices using the Verax SNMP Simulator (Linux/Windows) How to simulate network devices using the Verax SNMP Simulator (Linux/Windows) Table of contents Abstract... 3 1. Verax SNMP Simulator installation... 4 2. Extracting SNMP record files from a physical

More information

Working Folder Linkage Setup Guide

Working Folder Linkage Setup Guide For models listed below, see the respective "Working Foloder Linkage Setup Guide". wfs-mfp-installguide-09_en.pdf - ApeosPort-IV C5570/C4470/C3371/C3370/C2270 - ApeosPort-IV C7780/C6680/C5580 - ApeosPort-IV

More information

HP SCOM Management Packs User Guide

HP SCOM Management Packs User Guide HP SCOM Management Packs User Guide Abstract This guide describes the HP extensions for Microsoft System Center Operations Manager that are provided as part of HP Insight Control for Microsoft System Center.

More information

IntraVUE Plug Scanner/Recorder Installation and Start-Up

IntraVUE Plug Scanner/Recorder Installation and Start-Up IntraVUE Plug Scanner/Recorder Installation and Start-Up The IntraVUE Plug is a complete IntraVUE Hardware/Software solution that can plug directly into any network to continually scan and record details

More information

Sentinel Protection Installer Version 7.1.1 (Windows) ReadMe

Sentinel Protection Installer Version 7.1.1 (Windows) ReadMe Sentinel Protection Installer Version 7.1.1 (Windows) ReadMe This readme provides an overview of the Sentinel TM Protection Installer, its installation and a few tips on using the related components (such

More information

Software Installation Guide

Software Installation Guide Software Installation Guide This manual explains how to install the software over a USB or network connection. Network connection is not available for models SP 200/200S/203S/203SF/204SF. To manually configure

More information

Chapter 6 Using Network Monitoring Tools

Chapter 6 Using Network Monitoring Tools Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under

More information

Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1

Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1 Quick Install Guide Lumension Endpoint Management and Security Suite 7.1 Lumension Endpoint Management and Security Suite - 2 - Notices Version Information Lumension Endpoint Management and Security Suite

More information

Configuring Virtual Blades

Configuring Virtual Blades CHAPTER 14 This chapter describes how to configure virtual blades, which are computer emulators that reside in a WAE or WAVE device. A virtual blade allows you to allocate WAE system resources for use

More information

HP SCOM Management Packs User Guide

HP SCOM Management Packs User Guide HP SCOM Management Packs User Guide Abstract This guide describes the HP extensions for Microsoft System Center Operations Manager that are provided as part of HP Insight Control for Microsoft System Center.

More information

Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers

Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers Technical white paper Implementing Red Hat Enterprise Linux 6 on HP ProLiant servers Table of contents Abstract... 2 Introduction to Red Hat Enterprise Linux 6... 2 New features... 2 Recommended ProLiant

More information

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide Direct Storage Access Using NetApp SnapDrive Installation & Administration Guide SnapDrive overview... 3 What SnapDrive does... 3 What SnapDrive does not do... 3 Recommendations for using SnapDrive...

More information

Backup & Disaster Recovery Appliance User Guide

Backup & Disaster Recovery Appliance User Guide Built on the Intel Hybrid Cloud Platform Backup & Disaster Recovery Appliance User Guide Order Number: G68664-001 Rev 1.0 June 22, 2012 Contents Registering the BDR Appliance... 4 Step 1: Register the

More information

Rebasoft Auditor Quick Start Guide

Rebasoft Auditor Quick Start Guide Copyright Rebasoft Limited: 2009-2011 1 Release 2.1, Rev. 1 Copyright Notice Copyright 2009-2011 Rebasoft Ltd. All rights reserved. REBASOFT Software, the Rebasoft logo, Rebasoft Auditor are registered

More information

AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes

AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes AT-S84 Version 1.3.0 (1.0.0.90) Management Software for the AT-9000/24 Gigabit Ethernet Switch Software Release Notes Please read this document before you begin to use the management software. Supported

More information

Using a VPN with Niagara Systems. v0.3 6, July 2013

Using a VPN with Niagara Systems. v0.3 6, July 2013 v0.3 6, July 2013 What is a VPN? Virtual Private Network or VPN is a mechanism to extend a private network across a public network such as the Internet. A VPN creates a point to point connection or tunnel

More information

OnCommand Performance Manager 1.1

OnCommand Performance Manager 1.1 OnCommand Performance Manager 1.1 Installation and Setup Guide For Red Hat Enterprise Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Overview... 1 Requirements... 1. Installing Roles and Features... 3. Creating SQL Server Database... 9 Setting Security Logins...

Overview... 1 Requirements... 1. Installing Roles and Features... 3. Creating SQL Server Database... 9 Setting Security Logins... Contents CHAPTER 1 IMail Server using Failover Clustering Overview... 1 Requirements... 1 CHAPTER 2 IIS Installing Roles and Features... 3 CHAPTER 3 Configuring Storage Area Network Requirements... 5 Connecting

More information

Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010

Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 This document describes the different types of Unisphere management stations and tells how to install

More information

PTC Integrity Eclipse and IBM Rational Development Platform Guide

PTC Integrity Eclipse and IBM Rational Development Platform Guide PTC Integrity Eclipse and IBM Rational Development Platform Guide The PTC Integrity integration with Eclipse Platform and the IBM Rational Software Development Platform series allows you to access Integrity

More information

Embarcadero Performance Center 2.7 Installation Guide

Embarcadero Performance Center 2.7 Installation Guide Embarcadero Performance Center 2.7 Installation Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A.

More information

HASP Troubleshooting Guide

HASP Troubleshooting Guide HASP Troubleshooting Guide Corporate office: Trimble Geospatial Division 10368 Westmoor Drive Westminster, CO 80021 USA www.trimble.com Copyright and trademarks: 2005-2013, Trimble Navigation Limited.

More information

Online Backup Client User Manual

Online Backup Client User Manual For Mac OS X Software version 4.1.7 Version 2.2 Disclaimer This document is compiled with the greatest possible care. However, errors might have been introduced caused by human mistakes or by other means.

More information

Emulex Driver for Linux

Emulex Driver for Linux Emulex Driver for Linux FC and FCoE version 8.2.0.63 NIC version 2.101.374.0 iscsi version 2.101.374.0 User Manual P004433-01B Rev. A One Network. One Company. Connect with Emulex. Copyright 2003-2010

More information

WatchGuard Mobile User VPN Guide

WatchGuard Mobile User VPN Guide WatchGuard Mobile User VPN Guide Mobile User VPN establishes a secure connection between an unsecured remote host and a protected network over an unsecured network using Internet Protocol Security (IPSec).

More information

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Deploying Windows Streaming Media Servers NLB Cluster and metasan Deploying Windows Streaming Media Servers NLB Cluster and metasan Introduction...................................................... 2 Objectives.......................................................

More information

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual Serial ATA and Parallel ATA Host Controller Rev. 0.96 December 03, 2003 Copyright 2003 ULi Electronics Inc. All rights reserved. COPYRIGHT NOTICE All information in this document is considered ULi Electronics

More information

HL2170W Windows Network Connection Repair Instructions

HL2170W Windows Network Connection Repair Instructions Difficulty printing from your PC can occur for various reasons. The most common reason a networked Brother machine may stop printing, is because the connection between the computer and the Brother machine

More information

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015

Metalogix SharePoint Backup. Advanced Installation Guide. Publication Date: August 24, 2015 Metalogix SharePoint Backup Publication Date: August 24, 2015 All Rights Reserved. This software is protected by copyright law and international treaties. Unauthorized reproduction or distribution of this

More information

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples Networking General networking Networking overview A network is a collection of devices such as computers, printers, Ethernet hubs, wireless access points, and routers connected together for communication

More information

Citrix Access Gateway Plug-in for Windows User Guide

Citrix Access Gateway Plug-in for Windows User Guide Citrix Access Gateway Plug-in for Windows User Guide Access Gateway 9.2, Enterprise Edition Copyright and Trademark Notice Use of the product documented in this guide is subject to your prior acceptance

More information

-------------------------------------------------------------------- README.TXT

-------------------------------------------------------------------- README.TXT README.TXT Adaptec Storage Manager (ASM) as of June 7, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.

More information

Online Backup Client User Manual Mac OS

Online Backup Client User Manual Mac OS Online Backup Client User Manual Mac OS 1. Product Information Product: Online Backup Client for Mac OS X Version: 4.1.7 1.1 System Requirements Operating System Mac OS X Leopard (10.5.0 and higher) (PPC

More information

Online Backup Client User Manual Mac OS

Online Backup Client User Manual Mac OS Online Backup Client User Manual Mac OS 1. Product Information Product: Online Backup Client for Mac OS X Version: 4.1.7 1.1 System Requirements Operating System Mac OS X Leopard (10.5.0 and higher) (PPC

More information

Release Notes for Fuel and Fuel Web Version 3.0.1

Release Notes for Fuel and Fuel Web Version 3.0.1 Release Notes for Fuel and Fuel Web Version 3.0.1 June 21, 2013 1 Mirantis, Inc. is releasing version 3.0.1 of the Fuel Library and Fuel Web products. This is a cumulative maintenance release to the previously

More information

PowerChute Network Shutdown v4.1 Release Notes

PowerChute Network Shutdown v4.1 Release Notes PowerChute Network Shutdown v4.1 Release Notes The release notes provide important information about PowerChute Network Shutdown (PowerChute), including known software issues and their solutions. For any

More information

Network Connect Installation and Usage Guide

Network Connect Installation and Usage Guide Network Connect Installation and Usage Guide I. Installing the Network Connect Client..2 II. Launching Network Connect from the Desktop.. 9 III. Launching Network Connect Pre-Windows Login 11 IV. Installing

More information

Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice

Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice Phone Adapter with 2 Ports for Voice-over-IP Voice Installation and Troubleshooting Guide Model No. PAP2 Ver. 2 Copyright and Trademarks Specifications are subject to change without notice. Linksys is

More information

NOC PS manual. Copyright Maxnet 2009 2015 All rights reserved. Page 1/45 NOC-PS Manuel EN version 1.3

NOC PS manual. Copyright Maxnet 2009 2015 All rights reserved. Page 1/45 NOC-PS Manuel EN version 1.3 NOC PS manual Copyright Maxnet 2009 2015 All rights reserved Page 1/45 Table of contents Installation...3 System requirements...3 Network setup...5 Installation under Vmware Vsphere...8 Installation under

More information

Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family

Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family *5991-5301* Part number: 5991-5301 Edition: 3, E0406 Copyright 2006 Hewlett-Packard Development

More information

Virtual Storage Console 4.0 for VMware vsphere Installation and Administration Guide

Virtual Storage Console 4.0 for VMware vsphere Installation and Administration Guide Virtual Storage Console 4.0 for VMware vsphere Installation and Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

Configuring NXT Hardware with Mercury Inside into Doors.NET TM Application Note

Configuring NXT Hardware with Mercury Inside into Doors.NET TM Application Note 1.0 Installing the Mercury SCP Gateway The MSC/SCP gateway must be installed to interface with Mercury hardware. This gateway must be chosen during the installation of the software, or it can be added

More information

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,

More information