Low Voltage Products. Change-over and transfer switches Rotary change-over and bypass cam switches
|
|
- Cody Chandler
- 8 years ago
- Views:
Transcription
1 Low Voltage Products Change-over and transfer switches Rotary change-over and bypass cam switches
2 N Amps Change-over switches EC T16E T25E T32E T45E T63E l th /A l e /AC-22A, < 415V l e /AC-23A, < 415V T125E EC T160E T200E T250E T160E_W T200E_W T250E_W l th /A l e /AC-22A, < 415V l e /AC-23A, < 415V EC T315E T400E T630E T800E ETL100K ETL1250K ETL1600K l th /A l e /AC-22A, < 415V l e /AC-23A, < 415V S01575A FF N Accessories FF ptional handles Extended shafts Auxiliary contacts Terminal shrouds Connecting accessories Locking accessories 2
3 Change-over switches Transfer switches Rotary change-over and bypass cam switches Contents: pen transition switches Modular change-over switches T Technical data... 7 rdering information Modular change-over switches... 8 Accessories Contact functions Dimension drawings Change-over switches T , ETL and EM Technical data and operation functions rdering information Change-over switches, manual operation Change-over switches, motor operation Accessories Contact functions Dimension drawings Transfer switches ETL-NFC , UL approved Technical data rdering information Change-over switches...32 Accessories Contact functions Dimension drawings Closed transition switches Transfer switches ESC Technical data and contact functions rdering information Transfer switches Accessories Dimension drawings Rotary cam switches Rotary change-over and bypass cam switches M, N and L Technical data rdering information Change-over switches, M, N and L Bypass switches, N and L Accessories Dimension drawings
4 Secured power supply to diverse applications Change-over switch Change-over cam switch Special switches for secured power supply A secured power supply to diverse applications, from computers to industrial processes, is more and more important as the optimizing of costs for lack of production and maintenance is crucial for a successful business. The complex systems of distributing power in emergency cases are often controlled by logics, with mechanical devices for making & breaking, conducting and isolating power. n the other hand, the loads may need to be transferred from one supply to another. This is the case when the use of energy is restricted, when the supplying source is overloaded or when maintenance is required. ur solution for these installations are change-over or transfer switches with remote control by motor operator or manual local operation. The range consists of switches, mechanically interlocked to each other, with electrical characteristics that allow an onload switching between the two supplies. The isolation of the primary and secondary circuits is assured by the positive contact opening function and the reliable position indication. The switches can also be built by using available mechanism kits and standard switch-disconnectors. To meet the demands from different markets the change-over switches are tested according to EC and UL and certified by KEMA. Closed transition switch Tested according to EC Utilization categories: AC-31 for non-inductive or slightly inductive load, AC-33 for motor loads or mixed loads including motors. The tests are performed for frequent, suffix A, and infrequent, suffix B, operations. The endurance requirements for a change-over application between two power circuits under load is normally met only by a lifetime fulfilling EC
5 Local operation Closed transition switches for UPS applications Change-over switches The closed transition transfer switch is a make before break switch type which guarantees a transfer of the supply without any interruption. The switch is equipped with overlapping positions -. The change-over switch is equipped with three stable positions and is independent of external supply, in operations there is no risk of an unexpected opening of the switch due to loss of supply voltage and no supply voltage is necessary to keep the switch in the closed position. Two operation options Manual operation: using a handle fixed directly onto the switch, to the panel board or to the door of the panel board. This type of operation extends the operation time between the two supplies. Motorised operation: no human participation is needed for the intervention, and consequently the operation time between the normal and the alternate supply is short. Example of electrical (= 315 A) lifetime test: Number of operating cycles Suffi x Suffi x Test perating A B [A] cycle EC AC EC AC Remote control 5
6 pen transition switches Modular change-over switches The change-over switch carries out the switching and the reliable isolation between the primary network supply and the alternate supply, thus ensuring the continuity of performance. The modular change-over switch range T offers a most compact solution. The space requirements for a change-over switch is the same as for the switch-disconnectors next to each other. nly in depth it needs 11 mm in addition. t is easy to install: mounting onto 35 mm DN-rail and it s suitable for 45 mm cut-outs for consumer units. 6
7 Modular change-over switches Technical data Data according to EC Switch size T16_ T25_ T32_ T45_ T63_ T125_ Rated insulation voltage and rated operational voltage AC20/DC20 Pollution V degree 3 Dielectric strength 50 Hz 1min. kv Rated impulse withstand voltage kv Rated thermal current and rated operational / ambient 40 C n open air A current AC20/DC20 / ambient 40 C n enclosure A / ambient 60 C n enclosure A with minimum conductor cross section Cu mm Rated operational current, AC-21A up to 500 V A V A Rated operational current, AC-22A up to 500 V A V A Rated operational current, AC-23A up to 415 V A V A V A V A Rated operational power, AC-23A 1) The kw-ratings are accurate for 3-phase V kw 3 4 5, R.P.M. standard asychronous motors 400 V kw V kw V kw V kw Rated breaking capacity in up to 415 V A category AC V A V A V A Rated conditional short-circuit p (R.M.S.) 50 ka, 415 V ka current p (R.M.S.) and Max. FA_ fuse size gg/am A/A 40/32 40/32 40/32 100/80 100/80 125/125 corresponding max. allowed p (R.M.S.) 100 ka, 500 V ka cut-off current î c peak value. Max. FA_ fuse size gg/am A/A 100/80 100/80 The cut-off current î c refers to values listed by fuse manufacturers (single phase test acc. to EC60269). Rated short-time withstand current R.M.S. value cw 690 V 0.15s ka 690 V 0.25s ka 690 V 1s ka Rated short-time making capacity Peak value cm 690 V ka Mechanical endurance Divide by four for oper. per cycles 2) Cable size Cu-wire size suitable for mm terminal clamps AWG Terminal tightening torque Counter torque required Nm perating torque Typical for 3-pole Nm switch-disconnector Weight without accessories 3-pole switch kg pole switch kg Data according to UL508 (Listed) Current A Horsepower, 3-phase 200 V HP V HP V HP V HP V HP ) These values are given for guidance and may vary acc. to the motor manufacturer. 2) perating cycle:
8 Modular change-over switches rdering information S01415A FF T16E3C N FF N Modular change-over switches, 3 pole, -- -operation, open transition nclude terminal clamps, P20. Handle and shaft has to be ordered separately. T are UL Listed. Rated current / Rated power Cable cross Type rder number Weight AC-21A...AC-22A AC-23A section [kg] Up to 415V 400V V [A] S[kVA] [A] / P[kW] [mm 2 ] / T16E3C 1SCA022605R / T25E3C 1SCA022605R / T32E3C 1SCA022605R / T45E3C 1SCA022551R / T63E3C 1SCA022551R / T125E3C 1SCA022551R S01296A S01295A T E3C FF T125E3C N FF N Modular change-over switches, 4 pole, -- -operation, open transition nclude terminal clamps, P20. Handle and shaft has to be ordered separately. T are UL Listed. Rated current /Rated power Cable cross Type rder number Weight AC-21A...AC-22A AC-23A section [kg] Up to 415V 400V V [A] S[kVA] [A] / P[kW] [mm 2 ] / T16E4C 1SCA022551R / T25E4C 1SCA022551R / T32E4C 1SCA022551R / T45E4C 1SCA022551R / T63E4C 1SCA022551R / T125E4C 1SCA022551R S01282A FF N WC5D3 FF N FF N N Accessories Change-over kits The modular change-over switches can be built up by adding a compact snap-on kit on the top of two switch-disconnectors. The kits do not require any additional foot print area, only the height is increased 12 mm. For switches For shafts Type rder number Weight [kg] T16 32E XS5_, XP5_ WC5D1 1SCA022551R T45 80E XS5_, XP5_ WC5D2 1SCA022574R T E XS5_, XP5_ WC5D3 1SCA022574R Auxiliary contacts S00261A S01025A S00262A A1G01 A1G10 A7G10 A8G01 A2G11 TPS Snap-on mounting to the switch, P 20, max. 2 blocks/ side. Suitable for cable cross sections max. 2 x 2,5 mm 2. See the contact functions, page 10. For switches Contact nstallation Type rder number Weight functions side [kg] T E_C 1N Right A1G10 1SCA022353R T E_C 1NC Right A8G01 1SCA022744R T E_C 1N Left A7G10 1SCA022673R T E_C 1NC Left A1G01 1SCA022353R T E3C 1N+1NC Either A2G11 1SCA022379R th poles Snap-on mounting to the left or right side of the switches, P20. Simultaneous operation with power poles. For switches Rated current / up to 415V Type rder number Weight AC-21A /AC-22A AC-23A [kg] [A] [A] T TPS32EP 1SCA022348R T TPS63EP 1SCA022353R T TPS125EP 1SCA022379R
9 Accessories rdering information S01368A S01369A S01472A S01473A S01520A HR2 HR3 S00535A HB9 HB11 HB12 FF FF N N N 0 FF HB2_ S00050B S01026A XS5x_ H_ N Handles and shafts nternal handles, P20 No shaft needed, direct mounting on the top of the switch. For switches Colour Non Padlockable Type rder number Units/ Weight padlockable in 0-position type [kg] T16 63 Black x HB2/1 1SCA022660R Black x HR2 1SCA022648R Red x HR2/1 1SCA022660R Red x HR2 1SCA022645R Black x HB3/1 1SCA022659R Black x HB3 1SCA022648R Red x HR3/1 1SCA022660R Red x HR3 1SCA022648R T125 Black x HB9/1 1SCA022660R Black x HB9 1SCA022648R Red x HR9/1 1SCA022660R Red x HR9 1SCA022648R T125 Black x HB11/1 1SCA022692R Black x HB11 1SCA022680R T16 63 Black x HB12/1 1SCA022692R Black x HB12 1SCA022687R Red x HR12/1 1SCA022692R Red x HR12 1SCA022692R Selector type handles Selector handle, black P65, Nema type 1, 3R, 12, indication --. Padlockable in -position with maximum three padlocks with bail diameter mm (two lower holes) and mm (the upper hole). Door interlock in - and -position and when padlocked in -position. For switches Colour Type rder number Weight [kg] T Black HB2AJE011 1SCA022698R T Red-yellow HY2AJE011 1SCA022698R Shafts for selector type handles For switches Length Diameter Type rder number Weight [mm] [mm] [kg] T XS5x85 1SCA022347R XS5x105 1SCA022347R XS5x120 1SCA022347R XS5x130 1SCA022353R Pistol type handles, P65 The handles are equipped with door interlock function in both - and - position and when padlocked. Padlocking possibility in all positions with three padlocks, bail dia mm. ndication --. For switches Colour Type rder number Weight [kg] T Black HB45J5E311 1SCA022615R Red-yellow HY45J5E311 1SCA022615R Shafts for pistol type handles For switches Length Diameter Type rder number Weight [mm] [mm] [kg] T XP5x150 1SCA022376R XP5x170 1SCA022376R XP5x265 1SCA022376R XP5x400 1SCA022376R XP5x_ 9
10 Accessories rdering information, contact functions Terminal shrouds TS_T3 TS_T1 S02080A S02077A S02078A S01349A S01469A S01470A S00462A ZXA 32 ZXA 33 ZXA 38 ZXA 39 S02079A ZXA 40 ZXA 41 S00265A Snap-on mounting to the switches, P20. The full shrouding of a 3-pole change-over switch is achieved with four 3-pole shrouds. Suitable for Type rder number Weight [kg] For three pole switches T TS32T3 1SCA022353R T TS63T3 1SCA022353R T 125 TS125T3 1SCA022379R For fourth pole TPS 32EP TS32T1 1SCA022353R TPS 63EP TS63T1 1SCA022353R TPS 125EP TS125T1 1SCA022379R Parallel connection kits Finger protected connection bars for parallel connection of the upper or lower terminals. The bars accept additional cables, the maximum size is stated below. For switches Cable size [mm 2 ] Type rder number Weight [kg] T16 32E3C 6 (fine stranded), 10 (stranded) ZXA33 1SCA022685R T16 32E4C 6 (fine stranded), 10 (stranded) ZXA32 1SCA022683R T45 63E3C 25 ZXA38 1SCA022785R T45 63E4C 25 ZXA39 1SCA022790R T E3C 50 ZXA40 1SCA022790R T E4C 50 ZXA41 1SCA022790R Parallel connection terminal Terminal clamp for Al/Cu cables. The type includes 3 pcs. T125 2xAl/Cu 6 50 ZXT3 1SCA022639R nterlocking device for locks Cam attachment for Castell, Lowe & Fletcher or Ronis interlock. This accessory is mounted to the operating shaft of the switch and therefore only compatible with external handles. Lock, handle or shaft not included. T ETLZW16 1SCA022093R Contact functions for T Load Main contacts Main contacts Auxiliary contact N Auxiliary contact NC Auxiliary contact N Auxiliary contact NC A2G Position/ Primary network -Position/ Secondary network 0 0 ZXT_ S00059A ETLZW16 S01550A Auxiliary contact N Auxiliary contact NC Auxiliary contact N Auxiliary contact NC 10
11 Modular change-over switches Dimension drawings T H_45J5_ EN A1G01 29, TS32T3 TS32T1 TPS32EP A1G ,4 Ø N 0 FF N , L 12 2, ø4, (3-pole) 96 (4-pole) S01306A H_ 45J5E311 Shaft XP5x L T H_45J5_ ,5 45,5 EN A1G ,5 17,5 TS63T3 TS63T1 A1G10 TPS63EP ,5 9 17,5 0 FF Ø ,5 72,5 N N , L 43,5 58 5, , ,5 11 ø4,5 105 (3-pole) 140 (4-pole) S01298A H_ 45J5E311 Shaft XP5x L T EN ,3 A1G ,5 22,5 TS125T3 A1G10 TS125T1 H_45J5_ 10 TP_125EP Ø4,5 16 Ø FF ø4,5 N N 0 FF N S01299A 5 12 H _45J5E311 Shaft XP5x L 44 56,5 L , , ,5 140 (3-pole) 193 (4-pole) 11
12 pen transition switches Change-over switches S02054A The connection of supplies to busbar systems or the connection of the busbars to earth, ensuring safe power off, is secured in the change-over switch by the inbuilt mechanical interlocking and position change via FF-position. They prevent that parallel connection of two supplies could not occur, even in case of transient voltages. Transfer switch in ATSE n Automatic Transfer Switching Equipments the emergency power is automatically transferred to one or more load circuits from one supply to another by a logic system controlling the EM transfer switch. The switches are mechanically interlocked to prevent simoultaneous connection to both normal and alternative supplies and the operator independent quick make/quick break mechanism ensures distinct opening and closing of the contacts. The range is endurance tested as transfer switch according to EC categories AC-31 and AC-33, both for frequent and infrequent use, and is independent of which logic system is used for the automatic control. Load -Position/ Primary network -Position/ Secondary network Main contacts Main contacts 12
13 Change-over switches Technical data Data according to EC Switch size T160_ T200_ T250_ T315_ T400_ T630_ T800_ Rated insulation voltage and rated operational voltage AC20/DC20 Pollution V degree 3 Dielectric strength 50 Hz 1min. kv Rated impulse withstand voltage kv Rated thermal current and rated operational / ambient 40 C n open air A current AC20/DC20 / ambient 40 C n enclosure A / ambient 60 C n enclosure A..with minimum conductor cross section Cu mm x185 2x240 Rated operational current, AC-21A up to 500 V A V A Rated operational current, AC-22A up to 500 V A V A Rated operational current, AC-23A up to 415 V A V A V A V A Rated operational power, AC-23A 1) The kw-ratings are accurate for 3-phase V kw R.P.M. standard asychronous motors 400 V kw V kw V kw V kw Rated breaking capacity in up to 415 V category AC V V A V A Rated conditional short-circuit p (R.M.S.) 50 ka, 415 V ka current p (R.M.S.) and Max. FA_ gg/am A/A 355/ / / / / / /1000 corresponding max. allowed fuse size cut-off current î c peak value p (R.M.S.) 100 ka, 500 V ka Max. FA_ gg/am A 315/ / / / / / /800 fuse size The cut-off current î c refers to values listed by fuse manufacturers p (R.M.S.) 80 ka, 690 V ka (single phase test acc. to EC60269). Max. FA_ gg/am A 355/ / / / / / /1000 fuse size Rated short-time withstand current R.M.S. value cw 690 V 0.15s ka V 0.25s ka V 1s ka Rated short-time making capacity Peak value cm 690 V ka Mechanical endurance Divide by four for per oper. cycles 2) Terminal bolt size Metric thread mm M8x25 M8x25 M8x25 M10x30 M10x30 M12x40 M12x40 diameter x length Terminal tightening torque Counter torque Nm required perating torque Typical for 3-pole Nm switch-disconnector Weight without accessories 3-pole switch kg pole switch kg ) These values are given for guidance and may vary acc. to the motor manufacturer. 2) perating cycle:
14 Change-over switches Technical data Data according to EC Switch size ETL/ EM Rated insulation voltage and rated operational voltage AC20/DC20 Pollution degree 3 V Dielectric strength 50 Hz 1min. kv Rated impulse withstand voltage kv Rated thermal current and rated operational current AC20/DC20 / ambient 40 C n open air A / ambient 40 C n enclosure A / ambient 60 C n enclosure A with minimum conductor cross section Cu mm x 2x 2x 2x 2x 2x (60x5) (80x5) (100x5) Rated operational current, AC-21A up to 690 V A V A Rated operational current, AC-22A up to 500 V A V A V A Rated operational current, AC-23A up to 415 V A V A V A V A V A ) 150 4) 150 4) Rated operational power, The kw-ratings are V kw AC-23A accurate for 3-phase V kw R.P.M. standard 440 V kw asynchronous motors. 500 V kw V kw Cut-off current i 1) c r.m.s 50 ka, 690 V ka Cut-off current i 1) c r.m.s 100 ka, 500 V ka FAA/ FAM-fuse size A/ A / 630/ Rated short-time r.m.s. -value cw 690V, 1s ka ) 50 2) 50 2) Rated short circuit Peak value cm 690V/500V ka making capacity Mechanical endurance perating cycles 3) Terminal bolt size Metric thread diameter x length mm 8x25 10x30 10x30 10x40 12x40 12x40 12x60 12x60 12x60 Terminal tightening torque Counter torque required Nm perating torque 3-pole switches Nm Data according to EC Rated operational current, AC-31B up to 415 V A Rated operational current, AC-33B up to 415 V A Rated operational current, AC-31A up to 415 V A Rated operational current, AC-33A up to 415 V A ) The fuse in single phase test according to EC ) Maximum distance between busbar support and switch terminal 70 mm. 3) perating cycle: ) EC947-3, utilization category B, infrequent operation. 14
15 Motor operator Technical data Technical data for motor operator EM Rated insulation voltage (control circuit), U i perating temperature Rated control voltage Rated control frequency (230 VAC) 250V C x U s Hz Nominal voltage U s [V] Type peration time [s] when operating 0-, 0-, -0 or -0 peration time [s] when operating - or - FF-time [s] when operating - or - Min Max Min Max Min Max Max. continuous operating rate [cycles / h] Max. short-time ( 10 cycles) operating rate [cycles / h] 24 EM , EM EM EM EM EM EM EM EM Nominal voltage [V] perational current [A] Max. current [A] 230 VAC VAC/VDC 5 18 Connection diagram for supply and control wires (max. 2,5 mm 2 ) F3 L1 PE VAC/VDC peration functions Normal actions Continuous command peration cycle mpulse command peration cycle Minimum impulse duration 100 ms. Main Contacts Main Contacts Main Contacts Main Contacts Command Command Command Command S01538A Command Command Note! The switch position remains stable if the main voltage or the operation command disappears. See page 40 for suitable control switches for the operation circuit. Note! The switch position remains stable if the main voltage or the operation command disappears. ncorrect commands Continuous command f two overlapping commands remain on the switch changes its position between and continuously. This can be prevented by mechanical or electrical interlocks in the control circuits. mpulse command f the switch is in -, - or -position and two commands are given at the same time, the switch changes its position in occasional order. 15
16 N Change-over switches rdering information Manual change-over switches, 3-pole, -0- -operation, open transition ncluding a black plastic P pistol type handle, padlockable in the 0-position, door interlock in the - and -positions and when padlocked. Table below. T E03CP T E03CP T E03CP Rated current / Rated power Type rder number Weight AC-21A...AC-22A AC-23A Up to 415V 400V V [A] S[kVA] [A] / P[kW] [kg] Mechanism at the end of the switch /90 T160E03CP 1SCA022772R /110 T200E03CP 1SCA022771R /132 T250E03CP 1SCA022771R /160 T315E03CP 1SCA022772R /200 T400E03CP 1SCA022771R /355 T630E03CP 1SCA022785R /400 T800E03CP 1SCA022785R Mechanism between the poles /90 T160E12CP 1SCA022776R /110 T200E12CP 1SCA022776R /132 T250E12CP 1SCA022776R /160 T315E12CP 1SCA022776R /200 T400E12CP 1SCA022776R /355 T630E12CP 1SCA022785R /400 T800E12CP 1SCA022785R Mechanism at the end of the switch, with extended phase distance /90 T160E03WCP 1SCA022772R /110 T200E03WCP 1SCA022772R /132 T250E03WCP 1SCA022772R Mechanism at the right end of the switch /400 ETL1000K3C 1SCA022574R /400 ETL1250K3C 1SCA022574R /400 ETL1600K3C 1SCA022574R T E03WCP FF S01294A Shafts, handle and bolt kits included as standard ETL K3C Suitable for Shaft Handle Bolt kit switches T XP6x161 HB65J6E011 M8x25 T XP12x166 HB95J12E011 M10x30 T XP12x185 HB125J12E011 M12x40 ETL XP12x325 HB175J12E011 M12x60 16
17 N Change-over switches rdering information Manual change-over switches, 4-pole, -0- -operation, open transition ncluding a black plastic P pistol type handle, padlockable in the 0-position, door interlock in the - and -positions and when padlocked. Table below. T E04CP T E13CP T E04CP Rated current / Rated power Type rder number Weight AC-21A...AC-22A AC-23A Up to 415V 400V V [A] S[kVA] [A] / P[kW] [kg] Mechanism at the end of the switch /90 T160E04CP 1SCA022775R /110 T200E04CP 1SCA022771R /132 T250E04CP 1SCA022775R /160 T315E04CP 1SCA022775R /200 T400E04CP 1SCA022771R /355 T630E04CP 1SCA022785R /400 T800E04CP 1SCA022785R Mechanism between the poles /90 T160E13CP 1SCA022777R /110 T200E13CP 1SCA022777R /132 T250E13CP 1SCA022777R /160 T315E13CP 1SCA022777R /200 T400E13CP 1SCA022777R /355 T630E13CP 1SCA022785R /400 T800E13CP 1SCA022785R Mechanism at the end of the switch, with extended phase distance /90 T160E04WCP 1SCA022775R /110 T200E04WCP 1SCA022775R /132 T250E04WCP 1SCA022775R Mechanism at the right end of the switch /400 ETL1000K4C 1SCA022574R /400 ETL1250K4C 1SCA022574R /400 ETL1600K4C 1SCA022574R T E04WCP FF Shafts, handle and bolt kits included as standard S01411A ETL K4C Suitable for Shaft Handle Bolt kit switches T XP6x161 HB65J6E011 M8x25 T XP12x166 HB95J12E011 M10x30 T XP12x185 HB125J12E011 M12x40 ETL XP12x325 HB175J12E011 M12x60 17
18 Change-over switches rdering information S01316A S01315A S01305A l l EM K3C EM K3C EM K3C Change-over switches, motor operation, 3-pole, -0- -operation, open transition ncluding a metallic pistol handle, for manual operation. Rated current / Rated power Type rder number Weight AC-21A...AC-22A AC-23A Up to 415V 400V V [A] S[kVA] [A] / P[kW] [kg] Motor operation, operational voltage U n = 24V AC/DC /110 EM200K3C24AC/DC 1SCA022607R / 132 EM250K3C24AC/DC 1SCA022607R /160 EM315K3C24AC/DC 1SCA022607R /200 EM400K3C24AC/DC 1SCA022607R /315 EM630K3C24AC/DC 1SCA022607R /355 EM800K3C24AC/DC 1SCA022607R /400 EM1000K3C24AC/DC 1SCA022607R /400 EM1250K3C24AC/DC 1SCA022607R /400 EM1600K3C24AC/DC 1SCA022607R Motor operation, operational voltage U n = 48V AC/DC /110 EM200K3C48AC/DC 1SCA022607R / 132 EM250K3C48AC/DC 1SCA022607R /160 EM315K3C48AC/DC 1SCA022607R /200 EM400K3C48AC/DC 1SCA022607R /315 EM630K3C48AC/DC 1SCA022607R /355 EM800K3C48AC/DC 1SCA022607R /400 EM1000K3C48AC/DC 1SCA022607R /400 EM1250K3C48AC/DC 1SCA022607R /400 EM1600K3C48AC/DC 1SCA022607R Motor operation, operational voltage U n = 230V AC /110 EM200K3C230AC 1SCA022608R /132 EM250K3C230AC 1SCA022608R /160 EM315K3C230AC 1SCA022608R /200 EM400K3C230AC 1SCA022608R /315 EM630K3C230AC 1SCA022607R /355 EM800K3C230AC 1SCA022607R /400 EM1000K3C230AC 1SCA022607R /400 EM1250K3C230AC 1SCA022607R /400 EM1600K3C230AC 1SCA022607R Handle and bolt kits included as standard YASDA_ Suitable for Handle Bolt kit switches EM200 YASDA23/ 1 M8x25 EM YASDA23/ 1 M10x30 EM YASDA23/ 2 M12x40 EM YASDA23/ 3 M12x60 18
Breakers and Switches. Switches Change-over, bypass and transfer switches
Breakers and Switches Switches Change-over, bypass and transfer switches Change-over, bypass and transfer switches Product overview, features Product overview 4 Features 6 Technical data Manual / motorized
More informationLow Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
More informationBreakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM
Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical
More informationBreakers and Switches. Switches Automatic Transfer Switches
Breakers and Switches Switches Automatic Transfer Switches Growing importance of a secure power supply ABB s range of automatic transfer switches goes from 160 to 1600 Amperes. There are three types of
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationCatalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole
Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationSwitches for photovoltaic applications Switch-disconnectors OTDC and OTDCP
Contact us ABB y Breakers and Switches P.. Box 622 I-65101 Vaasa, inland Phone: +358 10 22 11 ax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions are
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationSafety detection solutions
Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationOTM_F_C_. Installation instruction 34OTM_F_C_ / 1SCC303009M0201
Change-over Motorized change-over switches switches _F_C_ Installation instruction 4_F_C_ / SCC0009M00 Installation instruction, _F_C_ Contents Mounting and dimensional drawings... 4 Mounting positions...
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationBreakers and Switches. Quick selection tool Accessories for switch-disconnectors and DC-switch-disconnectors
Breakers and Switches Quick selection tool Accessories for switch-disconnectors and DC-switch-disconnectors Quick selection tool Accessories for switch-disconnectors and DC-switch-disconnectors Contents
More informationFUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches
FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationType-Tested Power Distribution Board 8PT with Rear Busbars. sivacon
Type-Tested Power Distribution Board 8PT with Rear Busbars sivacon The Obvious Solution for Global Challenges SIVACON Type-testing is one of today s important issues for low-voltage technology and will
More information400 Series Buccaneer BUCCANEER POWER. bulgin
bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when
More information3K Load-Break Switches The Program for Safety and Performance. sentric
3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationInstallation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationTechnical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205. 8201 Schaffhausen 1 / 10
ABB ABB Schweiz AG Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M0205 09.04.2014 Page: 8201 Schaffhausen 1 / 10 Please use also the assembly instruction S800-RSU-H Remote
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationFixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits
Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationGeneral Informations 2 Technical data 3 Basic designs 4-8
Contents Page General Informations 2 Technical data 3 Basic designs 4-8 Cam Switches On-Off switches, Changeover switches 9-12 Star-Delta switches 13-15 Multi speed switches 16-20 Control switches 21-23
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationSICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A
s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationProtection and Connection. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole
Protection and Connection EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1 and 2-pole 2 Overview 3-pole 3 Overview 4-pole 4 Electronic Fuse Monitoring 5 Busbar Adapters
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationFuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationmecotron Safety relay ESTOP-2 For emergency stop monitoring
E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated
More informationUniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
More information1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide
1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationSystem pro M compact Miniature Circuit Breaker S 200/S 200 M
Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art
More informationZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationHS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.
y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock
More informationThe complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationKOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
More informationGeneral Purpose Relays Accessories. Accessories Miniature Relay PT
Miniature Relay PT n Easy replacement of relays on a densely packed DIN rail n No reduction of protection class or creepage/clearance with plastic retainer n Plug-in indicator- and protection modules n
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationGE Power Controls. MiniFORM Switchboards
GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules
More information