SY-486 Access Control Terminal - Controller Product Manual
|
|
|
- Winifred Cooper
- 10 years ago
- Views:
Transcription
1 Access Control Terminal - Controller Product Manual Product Manual SY486 - Synel Industries Ltd. Page 1
2 Manual dated 9/04/2009 Catalog no Part no. (-A ) All rights reserved. Reproduction or use, without express permission of editorial or pictorial content, in any manner is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this manual, Synel Industries Ltd. assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. DCM and SY are trademarks of Synel Industries Ltd. All trade names referenced herein are either trademarks or registered trademarks of their respective companies Product Manual SY486 - Synel Industries Ltd. Page 2
3 1. Introduction The is an access controller for control of up to two doors, gates or other barriers. Two separate readers may be connected. Each badge reader may be used to open and record the use of a different door, or both may be connected to different sides of the same door for independent control over entrances and exits. A variety of readers can be connected to, these readers are can hold an organization badge list. Furthermore, an optional PRintX unit can be connected for biometric validation purposes. Two separate sensors may be connected to verify passage and door closure, or for other purposes. The is designed to be installed with connections through a wall, which to secures them. Alternate connections may be used for installations where there is no threat of unauthorized disconnection and free access to these connections is desired. design particularly emphasizes on external devices fast-connection, such as readers, I/O, communication. This mode of connection without product disassembly is provided for quick and simple maintenance purposes. 1.1 Standard configurations Control over two different entrances as portrayed below: Product Manual SY486 - Synel Industries Ltd. Page 3
4 This configuration requires the use of only one relay and one sensor. Product Manual SY486 - Synel Industries Ltd. Page 4
5 2. Technical Specifications 2.1 Technical and interface specifications Two connectors for badge readers (PRX-30, SY-10/M, SY-10/B, reader unit) Connector for external PRintX, Connector for RS232/485/422 comport, RJ45 connector for Ethernet 512K of protected RAM Protected Real Time date/time clock Backup battery for the memory and Real time clock RS-232 and RS-485 communication Two relays for bell, door, etc. Two sensors (door monitoring) Variable baud rate to bps Net connection (Ethernet) - Flexible, well- developed IP protocol stack - Ethernet (10BASE- T or AUI) (STP/ UTP) - Telnet and SNMP management Options 2400 bps internal modem or 14,400 bps Wifi card POE Card. 2.2 Physical characteristics Dimensions: Height cm Width 25.cm. Depth 9.5 cm. Product Manual SY486 - Synel Industries Ltd. Page 5
6 2.3 Power requirements External Power Supply: Input Requirements Input Voltage: 100 (-10%) VAC to 240 (+10%) VAC Input Frequency range: 47 Hz to 63 Hz Input Power Consumption at no load: 0.5 W MAX Input Current 0.6 A MAX Output Requirements Output Voltage: 9.5 Vdc@1A Maximum input rating 12Vdc@2A Max DC current consumption: 1A Output Regulation: -10%, +10% Output Load: 2 A Connector Type: TIP 5.5 * 2.5 Product Manual SY486 - Synel Industries Ltd. Page 6
7 2.4 Terminal Features Memory 256 Function keys 3 Numeric keys 10 Control keys 4 Fingerprint Yes Magnetic reader Yes Wiegand reader Yes Modem Yes TCP/IP YEs 2.5 Communication and configurations Communication parameters Communication between the host and terminals is performed under an asynchronous mode. The baud rate is programmable, enabling rates from 1200 to bps Multiple terminal configuration RS-485 communication enables you to connect up to 32 terminals to a single COM port and/or to extend the cabling distance to up to 1,000 meters (3,280 feet) using 9600 baud via an RS-485 multi-drop line. RS-485 communication uses two wires as opposed to RS-422 communication, which uses four wires Port to port configuration A single terminal, equipped with RS-232 communications, can be connected directly to an asynchronous RS-232 port. If RS-232 communication is used, only one terminal may be connected to each COM port and cabling distances should not exceed 50 meters (160ft) Network connections The terminal can be connected to one of the following communication networks: Ethernet - For this type of communication, an IP address is defined for every terminal, enabling communication with each terminal in TCP/IP protocol. Product Manual SY486 - Synel Industries Ltd. Page 7
8 Technical Specification Table Card access current ~5V Module current ~3.3V Idle power consumption 15mA Working power consumption 40-75mA Ripple on card 5m V P-P Ripple on module 5m V P-P Pressure on power source at complete ~7.36V terminal capacity with an internal BT or BAT reader without an FPU or external reader Complete power consumption from ~350mA power source at complete terminal I(JP11)<1A(~250mA) capacity with an internal BT or I(V1)<<1A(small) BAT reader without an FPU or external I(BAT)~100mA reader 2.5. Selection of the data entry function The terminal is ready for operation when a data entry function has been selected (after it was programmed). The prompt of the selected function will be displayed on the second line. To select a function, press the desired function key prior to entering the data. Product Manual SY486 - Synel Industries Ltd. Page 8
9 Apparatus The terminal and controller is enclosed in a rugged plastic molded casing and are secured to the wall using four screws and a removable panel Product Manual SY486 - Synel Industries Ltd. Page 9
10 Front panel: 1. A 32 character LCD with a back light display is located in the upper part of the front panel. Two arrow keys are located to the right of the display panel for line up and line down maneuvering. 2. Two function keys are located on the left, below the display, and are F1 & F2. 3. Numeric keys. 4. The Alarm light is located to the left of the display. The alarm light is a LED that lights when at least half of the memory is used; it blinks when the memory is full or when the terminal has not been programmed. 5. The ON button enables a 15 seconds (modifiable using program) manual operation. 6. FP button for (Enroll, Delete and Check) 7. A Biometric fingerprint reader of FPU-s type which supports thousands fingerprints templates (9090 for FPU-s) for verification and identification. FPU is minutia based and uses the following technology: - Optical sensor - Capacitance sensor - Authentic sensor Product Manual SY486 - Synel Industries Ltd. Page 10
11 Bottom connector panel The connector panel is located at the lower part of the casing, withholding the socket openings for all external connections as follows: 1. Power supply 9.5 VDC connector 2. Two external readers 3. I2C for future connection 4. Network RJ45 5. Serial Comport RS232C 6. Host RS-232/485 Product Manual SY486 - Synel Industries Ltd. Page 11
12 2.3. Internal components Battery back-up modules The terminal has two back-up battery modules, one for the real time clock memory and the other for operation during a power failure. The standard memory back-up module is a lithium battery, which will keep the internal clock running and the memory intact, for 30 days during a power failure. The backup battery provided (in addition to the standard memory back-up) is a self-recharging system which allows the terminal to be operated during a power failure. The battery provides power for one and a half net hours of use. A shutdown timeout feature enables the terminal to operate for more extended periods of time. There are two types of timeout shutdowns: The firmware default timeout of 15 seconds. This option is used if the terminal has not been otherwise programmed (to a different timeout), if the application specifying otherwise has not been loaded or if there is an error in the application The user defined timeout shutdown defined by programming the terminal using the SY protocol. Once this option is uploaded to the terminal it is used at starting the terminal at Power On. The default firmware battery shutdown timeout is 15 seconds. This timeout is used unless a different timeout has been programmed to the terminal using the Synel Protocol and uploaded to the terminal. During a power failure, the user presses the battery key to activate the terminal. Data can then be entered and stored in the terminal memory. The timeout will cause the terminal to shut down automatically after the last use of the terminal, until the battery key is pressed again Memory The terminal contains a 256 Kbyte user memory RS-232/485 internal Card This card provides an RS-232/485 serial interface. Unpacking Note: Do not throw away the box or packing materials. Check the box and contents for signs of damage that may have occurred during shipment. After checking the box, carefully unpack and check for the following items: 3.1. Contents The package contains: 1 terminal Mounting panel / Connector cover Short TCP/IP communication bridge cable (included only when network communication is available) Four Phillips flat head 3.5x30mm and anchors, for terminal mounting purpose Regulation & sampling instruction for fingerprint (document number ) Product Manual SY486 - Synel Industries Ltd. Page 12
13 Installation 4.1. Selecting the Terminal Location When selecting a place to install a terminal with wireless network communication you need to consider environmental factors that affect the connection. The optimal location is where: Communication to the terminal is not blocked by walls or metal obstacles. This can be done by standing at the location where the terminal is to be installed and viewing the area to make sure that it is clear. Antennas should are positioned so that they are parallel to one another. If there are obstacles between the terminals, antennas should be positioned for the best clear connection between them. For example, at floor level below the obstacle or at ceiling level above the obstacle, especially with metal obstacles. Do not install the terminal in a location where people gather and linger since they, too, block the connection and also as to not expose them to radiation. Product Manual SY486 - Synel Industries Ltd. Page 13
14 4.2. Mounting the terminal on a wall Make sure the unit is not plugged into a power source. If you have already connected your terminal to a PC, disconnect it. You can reconnect it after you have completed mounting the unit. Caution: The terminal contains computer components. It should not be mounted where it will be exposed to extreme heat or cold, water, steam, violent vibrations, high electromagnetic radiation including high voltage power lines and electrical equipment. Step 1: Select a location for the terminal. The following guidelines will help you find the best place for the terminal: The terminal should be placed by an easily accessible power outlet. Make sure that there is enough space around the terminal for the communication cabling. Do not place the communication cable near a source of electromagnetic radiation or radio interference such as power lines, large machinery, etc. If the communication cable is to be wired through the wall, make sure that it is safe to drill a hole at the desired location. For best usability the terminal should be mounted at employee height. The recommended height is 140cm (4 7 ). Step 2: Remove the back mounting panel by sliding it to the side and pulling it out. A - Screw holes - for screwing the mounting panel in place. B - Entrance for cables wired from the wall. C -Clasps for holding cables in place. D - For cable entering terminal from below. E - Security fastener. E A B A C A D A Product Manual SY486 - Synel Industries Ltd. Page 14
15 Step 3: Prepare the wall for mounting by placing the panel on the wall as a template and mark the place for drilling the holes (A). Step 4: Drill holes using a 6 mm. (1/4") drill bit. The cables can be wired through the wall and positioned in the clasps (C) to the bottom of the terminal where that are connected, or be wired directly from the bottom of the terminal (D). Step 5: Position the panel so that all of the wires are in place and screw the panel to the wall. Step 6: Wire all of the cables through the mounting panel and position the electric socket in its place in the mounting panel (F). Step 7: Connect the communication cables to the terminal. Plug one end of the communication cable into the communication socket of the terminal. If an internal modem has been added and the modem is used, plug the RJ-45 connector of a standard telephone cable into the telephone line. Do not use the communication cable. Step 8: Slide the terminal into place. Step 9: Screw the security fastener into place (E). Product Manual SY486 - Synel Industries Ltd. Page 15
16 4.3. Communication connections Step 1: Select a location for the connection box. The box must be positioned where both the communication line and the terminal can be connected to it. The terminal should be placed near the connection box, and must be within the reach of the short RJ45 cable. Step 2: Plug the communication cable from the terminal into the connection box. Step 3: Wire an additional connection for Ethernet. 5. Technician Mode (Setup) setup is performed using the programming display panel. Power on the unit. In technician mode you can set-up: - Real Time Clock (RTC) Calibration (Do not change) - Baud rate - Station ID settings - Modem rings - Internet connection Step 1. Enter into the Technician Mode: Option 1 Terminal is programmed then swipe the technician card or 6 times in & out simultaneously. Option 2 Terminal is not programmed, a no prog. message is displayed. Press 6 times on the 0 key. Step 2. Adjust the RTC (N/Y): This adjustment option is for internal clock calibration purposes. For detailed instructions refer to Paragraph Calibrating the Real Time Clock (RTC). Step 3: Set date and time: The date is in DD.MM.YYYY format Note: Setting date and time is enabled only when defining the system parameter in the SYncomm software: Edit Program--> System--> Badge type choose S (System Administrator)! Step 4: Adjust host baud rate: Available baud rates: 1200, 2400, 4800, 9600 (default) and Step 5: Adjust fingerprint unit baud rate: Available baud rates: (default), 9600, and Step 6: Adjust printer baud rate: The available baud rates are: 9600 (default), 1200, 2400 and Step 7: Adjust station ID: The Station (terminal) ID is the s address on a communication line. It enables multi-terminal communication. Any number from 0 to 31 may be used as the terminal ID. Again, scroll to the required Station ID number. Step 8: Adjust the amount of modem rings: Choose either the number of rings or N for no rings. Step 9: Network connection: Programming the network connection requires addressing several sub-topics. The main screen enables three modes: N for no connection, A (10Base) or B (10/100Base new card) for answering when the terminal has been addressed. Polling Y/N For polling the user will be asked to choose between Y and N. Then, the terminal will send data to the server as per the Polling sec. definition. Product Manual SY486 - Synel Industries Ltd. Page 16
17 Polling Sec Determines the frequency of data transmission to the SY-Server software. If your terminals are not in online (query) mode, define the polling time as approximately sec. Otherwise, raise polling time to avoid network collisions. Use the numeric keys to define your required polling time. MAC SEND (Y/N) If you want to confirm sending your terminal s network MAC address to the host. Then after exiting technician mode the terminal will send the host a Hardware configuration network message informing it of its MAC address, IP etc. My MAC Address Displays your MAC address on your terminal s prompt. here your terminal s MAC address will be displayed. My IP Address Press line up/down to view the TCP/IP address of the terminal. Use the numeric keys to enter the IP Address. Gateway Address Press line up/down and key-in the required gateway address. Remote Address Press line up/down to view the TCP/IP address of the personal computer on which the SY-Server runs. Use the numeric keys. Subnet Mask The subnet mask is the network address plus the bits reserved for identifying the subnetwork. Use the numeric keys to determine the terminal s subnet mask affiliation within your local net. My Port TCP/IP enables connecting multiple applications via the same address. The port number selected here is the application identification number used by the computer when communicating with the terminal. Synel applications use the default port number = 3734 (a designated Synel port). However, you may change this according to your specific needs. Host Port Synel applications use the default port number=3734. However, you may change this according to your specific needs. Use the numeric keys to change the port number. Disconnect Sec Disconnect seconds defines the number of waiting seconds before reverting to offline mode. Click 03 to enable a fast disconnection. Product Manual SY486 - Synel Industries Ltd. Page 17
18 DHCP (Y/N) To automatically assign a dynamic IP address to your terminal choose Y. Note: If no IP address was filled-in under My IP Address, then you must use DHCP, therefore the only option available will be Y! User Field A field in which the user can fill-in 4 digits that will characterize that terminal. This data can also be sent to the terminal via a system table. This value is sent to the host when the Status command is used. 6. Host Computer Interfacing There are a number of different communication standards through, which communication takes place, each with its own characteristics. The data collection terminal can be connected to the host computer using an RS-232 or an RS- 485 connection with an asynchronous serial port. The drawing below illustrates direct (RS-232) connection on the left and multi-drop (RS-485) connection on the right. RS-232 is used for single device, point to point connection, for distances up to 50 meters (160 ft). RS-232 is the communication standard used by nearly all PCs and modems. It enables point to point connection of terminals. Cabling distance is limited to 50 meters (160 ft). Only one terminal can be connected to a COM port. The RS-485 standard extends the potential cabling distance to 1,000 meters (3,280 feet) using 9600 baud and enables more than one device to be connected to the same COM port. It uses only two communication wires. The SY-65 communication adapter converts RS-232 to RS-485. Note: Most computers use DTE type connectors on their RS-232 ports. The is equipped with an RJ45 (telephone jack) connector. Therefore, you will need a RJ-45 to D-Type adaptor between the terminal and the host. 6.1 Communication cables characteristics These guidelines should followed when installing the communications cables. 1. The cable should not be installed near EMI sources, such as: - Motors, generators, alternators, and transformers, Air conditioners, elevators, Radio/television transmitters, signal generators and internal communication networks 2. Cables should not be within 30 cm. (1 foot) of power lines < 5 KVA. 3. Cables should not be within 60 cm. (2 feet) of power lines in the 5-10 KVA range. 4. Cables should not be within 1.5 meters (5 feet) of power lines of more than 10 KVA. 5. The cables should not run parallel to power lines for more than 15 meters (49 feet). 6. It is best to use a single continuous cable for the communication line. If this is not possible, the cable should have only one connection, indoors, in one of these ways: a Using two connectors with appropriate shielding and cover. b. Using a connection box. 7. For aerial installation, use N.Y.Y. shielded cables. Product Manual SY486 - Synel Industries Ltd. Page 18
19 6.2 Connecting your PC to the SY-65 The SY-65 must be set to one of the RS-485 modes, i.e. 4, 5, 6 and 7. For more information, refer to the manual for the SY-65 communication adapter. The diagrams below describe the pin outs for the cable used to connect your PC to the SY-65 communication adapter. If your PC contains a 9-pin connector refer to the first diagram, if it contains a 25-pin connector, refer to the second diagram. Note: RTS cannot be used with SYNMAN communication software. Product Manual SY486 - Synel Industries Ltd. Page 19
20 6.3 Connecting the SY-65 to 8 pin connection box A 24 gauge, shielded two wire twisted pair cable should be used to connect the SY-65 to a connection box. Step 1. Open the connection box. Step 2. Connect the -TRX wire to the connection marked OR. Step 3. Connect the +TRX wire to the connection marked BK. Step 4. Connect the shield wire to the connection marked RD. Step 5. Close the connection box If communication problems occur 1. Check if RTS Cable is disconnected. 2. Lower the baud rate, in both sides ( & Communication software). 3. Use cables with a heavier gauge conducting wire. 4. Connect 100 ohm resistors between the MRxD and PRxD, and also between MTxD and PTxD that are t the ends of the wire on the last terminal of the multi-drop line. 5. EMI protection is integrated into the terminal, but it is best to use an external protector for lightning problems. 6.4 Making a multi-drop connection Note: Terminal IDs are set at the terminal using the control badge. There is no procedure for hardwiring the terminal ID as in the SY-7XX and SY-4XX terminals. All terminals and their connection boxes are connected in exactly the same way, regardless of their terminal IDs. The multi-drop line may be created in one of two ways: creating a chain of connection boxes, using a junction box Cable from the to the host connection box This is a standard 8 wire telephone cable with RJ45 connectors cable and is supplied with the terminal. Product Manual SY486 - Synel Industries Ltd. Page 20
21 Method 1 The SY-65 is connected to a connection box, which in turn connects to another connection box, thereby forming a chain. Method 2 The SY-65 is connected to a junction box. A separate cable is connected from each connection box to the junction box. 7. Maintenance 7.1 Once a month Clean the badge reader: 1. For magnetic badge readers use a special cleaning badge made of plastic with a polishing paper (made of Al2O3, with a grain size of approximately 16 microns) attached to the part of the badge where it contacts the magnetic head. Swipe the badge once or twice. Excessive polishing will result in wearing out of the magnetic reader head. 2. For barcode badge readers use an air gun to remove dirt/dust/a special optical cleaner (e.i.: used for eye glasses to wipe dirt and dust off). Caution: Alcohol based cleaning solutions must never be used to clean bar code readers. 7.2 Once every six months 1. Check the voltage of the UPS battery. If it is less than 7 volts, change them. Also make a visual check for leakage. 2. Clean all electrical contacts inside the terminal with a contact cleaner. 3. If a magnetic badge reader is used, clean it with a cleaning solution (such as pure alcohol). 4. Remove the JP7 jumper (1). 5. Check the voltage of the memory back-up battery and make sure that it is between 2.8V and 3.1V. 6. Replace the JP14 jumper (1). 7. Tighten the screws holding the power cable to the CPU card. Verify that the components which have been assembled in the sockets are well adjusted. 7.3 Calibrating the Real Time Clock (RTC) Warning: This operation must be performed by qualified and authorized personnel only! This operation equires that you work with an open unit. Make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source. Failure to heed this warning may result in harmful contact with electrical current. If your terminal gains or loses time, you will need to calibrate it using a Time Counter unit, which has at least 5 places to the right of the decimal point (100,000ths of a millisecond). Product Manual SY486 - Synel Industries Ltd. Page 21
22 Refer to Jumper drawing (detailed) 1. Connect the programming panel. 2. Unplug the terminal and make sure that it is off. 3. Unscrew and remove the front panel. 4. Remove the JP12 jumper. This disables the Watchdog utility. 5. Plug the terminal into a power source and enter the technician mode. Refer to Technician Mode (Setup). 6. Make sure that the Time Counter is unplugged. 7. Connect the ground of the Time Counter unit to the ground pin at TP2 of the terminal s CPU board. 8. Reposition JP13 to 2-3 (calibration). 9. Connect the input of the Time Counter unit to the pin marked in JP13 jumper Plug the Time Counter unit a power source. 11. Set the Time Counter unit to test the period. 12. Press once on "in"; the message "adjust RTC yes/no" appears. 13. Press once on "out" for yes, ("in" for no). 14. Calibrate the RTC of the terminal to milliseconds by turning the screw on the variable capacitor at C Disconnect Jumper 2 pin at JP Replace the JP13 jumper to 1-2 position. 17. Disconnect the connector from TP2 of the terminal s CPU board. 18. Return the JP12 jumper to re-enable the Watchdog utility. 19. Unplug the terminal. 20. Replace the front panel. 21. Unplug the Time Counter. 7.4 How to cause a memory crash Warning: This operation must be performed by qualified and authorized personnel only! This operation requires that you work with an open unit. Make sure to unplug the unit wherever the instructions call for it. Take extreme care during the stages where the terminal is plugged into a power source. Failure to heed this warning may result in harmful contact with electrical current. Step 1. Unplug the terminal and make sure that it is off. Step 2. Unscrew and remove the front panel. Step 3. Remove the JP4 jumper from the 1-2 position to 2-3 position. Step 4. Reposition JP4 to (1-2). Step 5. Plug the terminal back into a power source and make sure that MEM CRASH reappears on the programming panels display. Product Manual SY486 - Synel Industries Ltd. Page 22
23 7.5 Formatting the memory if a crash occurs If the memory crashes the following message will appear on the programming panel display: CRASH: You will need to clear the terminal s memory and return the terminal to the NO PROGRAMMING state according to the procedure below. Step 1. Connect the programming panel. Step 2. Press 6 times on the 0 key. An asterisk appears for each time that this key is pressed. Step 3. Press once on the Enter key. Step 4. Press 3 times on the F1 key. Step 5. Press twice on the F2 key. Step 6. Press 3 times on the F1 key. The message CLEAR MEMORY? will appear on the display. Step 7. Press once on the F2 key for confirmation. The message MEMORY CLEARED will appear on the display. This will cause the terminal to enter the technician mode. The message on the display will alternate between TECHNICIAN MODE and the date and time in the following format: DD/DW hh:mm:ss where DW represents the day of the week. If you make an error during steps 3 through 6, the terminal will revert to the state just prior to step 3. If you find yourself unable to complete this operation, exit the technician mode by pressing the F2 key until F2 appears on the display, then press the F2 key. Then begin again from step 1. Product Manual SY486 - Synel Industries Ltd. Page 23
24 8. Connectors & Jumpers layout Components side (PCB no C) Product Manual SY486 - Synel Industries Ltd. Page 24
25 Synel Industries Ltd. 2 Hamada St. POB 142, Yokneam Industrial Park, Israel, Tel: Fax: Site: Tel-Aviv Branch Tel: UK Branch Tel: NA Branch Tel: Product Manual SY486 - Synel Industries Ltd. Page 25
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM
TIME BOX BIOMETRIC TECHNICAL INSTRUCTIONS AND QUICK START GUIDE IT IS RECOMMENDED TO READ THIS MANUAL BEFORE OPERATING THE SYSTEM BODET Software B.P. 402 Boulevard du Cormier F-49302 CHOLET Cedex www.bodet.com
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
M O D U L E - 7 E Model CS-Caliprompter Operator s Manual
O P E R A T I O N S A N D P R O C E D U R E S F O R C S - C A L I P R O M P T E R A N D A C C E S S O R I E S Model CS-Caliprompter Visual screen display allows easy step-by-step operation On-site programming
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
Follow these steps to prepare the module and evaluation board for testing.
2 Getting Started 2.1. Hardware Installation Procedure Follow these steps to prepare the module and evaluation board for testing. STEP1: Plug the EG-SR-7100A module into the sockets on the test board.
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
PCS300 Universal IP Reporting Module V1.0
PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
UPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design
XPanel V2 Remote Control Panel User Manual XILICA Audio Design Important Safety Instructions 1. READ THESE INSTRUCTIONS All the safety and operating instructions should be read before the product is operated.
USING THE MODEL V800 VELOCITY CLOCK
USING THE MODEL V800 VELOCITY CLOCK Velocity Clocks are advanced clocks with many options and features. They can be used to restrict employee punching, allowing employees to punch at the clock during their
Installation Instructions. Wireless Adapter/Repeater. Introduction. 30-3001-887 Rev C
/Repeater Installation Instructions 30-3001-887 Rev C Workstation Ethernet bcx Controller Repeater Repeater Introduction Schneider Electric has designed a device that allows Andover Continuum controllers
Setting Up the ZigBee Ethernet Gateway
Setting Up the ZigBee Ethernet Gateway MAN-01-00030-1.4 This manual describes how to install and set up ZigBee communication between a SolarEdge device (Inverters or Safety and Monitoring Interface) and
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network
IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This
HLWLAN 802.11b/g/n Transceiver Kit
092524 RevB HLWLAN 802.11b/g/n Transceiver Kit Wireless Communications for OmniLogic Owner s Manual Contents Introduction...1 Installation...2 Configuration...6 Operation...8 Troubleshooting...9 HLWLAN
Modbus RTU (RS-485) TCP/IP (Ethernet)
Eaton Innovative Technology PEM PC Software Installation and Operation Instruction Manual: IM01005006E Rev. 2 March 2007 Modbus RTU (RS-485) TCP/IP (Ethernet) Effective Date 3/2007 For more information
Crow Limited Warranty. Print Version 017
Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose
Bluetooth to Serial Adapter
Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3
SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
USB Plus+ RFID Reader Setup Guide
875-0042-03 RevA USB Plus+ RFID Reader Setup Guide 1 Government Limited Rights Notice: All documentation and manuals were developed at private expense and no part of it was developed using Government funds.
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice
Phone Adapter with 2 Ports for Voice-over-IP Voice Installation and Troubleshooting Guide Model No. PAP2 Ver. 2 Copyright and Trademarks Specifications are subject to change without notice. Linksys is
User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400
User Manual PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400 PePWave Mesh Connector Indoor Series: MC 200, E200, 400 PePWave Surf AP Series: Surf AP 200-X, E200-X, 400-X PePWave Surf
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
About This Guide SolarEdge Configuration Tool Software Guide. About This Guide
About This Guide 3 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers, administrators and integrators who are authorized to configure
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems
SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and
8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
All other brands and their products are trademarks or registered trademarks of their respective holders, and should be noted as such.
Administration Guide June 20, 2006 Copyright 2006 by Equitrac Corporation All rights to this document, domestic and international, are reserved by Equitrac Corporation. No part of this publication may
Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220
Installation Guide Wireless N Access Point EAP110/EAP120/EAP220 CONTENTS Network Topology 01 Hardware Overview 02 Hardware Installation 05 1. Installation Requirements... 05 2. Mounting Bracket... 05
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
LDG DTS-4/4R Desktop Coaxial Switch / Remote
LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 [email protected] www.ldgelectronics.com
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
CONSOLE REMOTE I /O AC 9V
CONSOLE CONSOLE REMOTE I /O AC 9V AC 9V REMOTE I /O User Manual CE-220 Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units
Quick Start Guide. GV-AS Controller
Quick Start Guide GV-AS Controller Thank you for purchasing GV-AS Controller (GV-AS100 / AS110 / AS120 / AS210 / AS400 / AS810). This guide is designed to assist the new user in getting immediate results
Wash Select II to WashPay Integration Field Retrofit Installation Guide
Wash Select II to WashPay Integration Field Retrofit Installation Guide Wash Select II Software Version 6.00 and above POS4000 Software Version 8.25 Unitec www.startwithunitec.com WASH SELECT II TO WASHPAY
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
GEU-0822 8-Port Gigabit Switch
GEU-0822 8-Port Gigabit Switch 1 V1. 1_20150622 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...
Box Camera Series Hardware Manual
Encoder Firmware V4.06.09 User s Manual Box Camera Series Hardware Manual D21 (D21F / D21V) D22 (D22F / D22V) E21 (E21F / E21V) E22 (E22F / E22V) E23, E24, E25 2013/08/27 Table of Contents Precautions...
How To Use A 1232 On A 1236 On A Computer Or A Cell Phone
12-36-1000 Autodialler and Relay Telephone Interface 1.0 INTRODUCTION 12-36-1000 I/O Telephone Interface with AutoDialer The 12-36-1000 is a autodialer and telephone interface that can be used autonomously
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:
BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960 This manual covers installation and operation procedures for BNC AM members: Berkeley Nucelonics - 2955 Kerner Blvd. San Rafael, CA 94901 - (415)453-9955 -
Installation manual. Version 1.1. www.videx-security.com
Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes
dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes 751 Legal Information First English printing, October 2002 Information
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
Network Management Card. User Manual
User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
ABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
SmartLogger1000. Quick Installation Guide. Issue 05. Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD.
Issue 05 Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of
DSX Master Communications
DSX Access Systems, Inc. PC to Master Controller - Direct Connect Communications DSX Master Communications Communications between the Comm Server PC and the Master Controller can take several forms which
MTX-15 TM. Data Collection Terminal. Installation and Operation Guide
MTX-15 TM Data Collection Terminal Installation and Operation Guide Proprietary Notice Thank you For purchasing another fine product from Amano Cincinnati, Inc. This document contains proprietary information
SECTION 13850 DETECTION AND ALARM
SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring
RC2200DK Demonstration Kit User Manual
Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400
PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
IEEE 802.11b WLAN PC Card
IEEE 802.11b WLAN PC Card User s Guide Version: 1.3 August 2001 Please install the Utility/Driver first before inserting the PCMCIA Card. FCC Class B Radio Frequency Interference Statement The manufacturer
WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054
WIRELESS ALARM KIT COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS Model Number: IT214054 INSTRUCTION MANUAL Warranty Details/Support This product is warranted against defects for a period of One year if the
HWg-STE HWg-STE PoE MANUAL
HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.
HyperAccess Access Control System
Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000
Controller 5000GL Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. GGBUS L LOCAL BUS
WAP3205 v2. User s Guide. Quick Start Guide. Wireless N300 Access Point. Default Login Details. Version 1.00 Edition 2, 10/2015
WAP3205 v2 Wireless N300 Access Point Version 1.00 Edition 2, 10/2015 Quick Start Guide User s Guide Default Login Details Web Address http://zyxelsetup Password www.zyxel.com 1234 Copyright 2014 ZyXEL
DK40 Datasheet & Hardware manual Version 2
DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...
Contents. Section A Networking Basics... 1. 1 Learning the Basics... 3. Section B Wired Ethernet Networking... 17
Contents Section A Networking Basics...................................... 1 1 Learning the Basics............................................. 3 Selecting a network connection........................................
Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)
February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,
Ethernet Radio Configuration Guide
Ethernet Radio Configuration Guide for Gateway, Endpoint, and Repeater Radio Units April 20, 2015 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com Phone 208-323-1634 FAX 208-323-1834
2 Setting Up the Hardware for a Wired Ethernet Network... 13. 3 Setting Up the Software for an Ethernet Network... 21
Contents 1 Networking Basics............................................... 1 Selecting a network connection........................................ 2 Wired Ethernet network...........................................
Bluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
Network Interface Panel User s Guide NPD4747-01 EN
User s Guide NPD4747-01 EN Contents Contents Copyright and Trademarks Safety Instructions Important Safety Instructions... 4 Cautions and Notes... 4 Getting to Know Your Network Interface Panel Package
Connecting to the Internet
Connecting to the Internet Connecting the Gateway to the Internet Configuration of TCP/IP Protocol Installing the USB Drivers Connecting Ethernet Network Devices Connecting USB Network Devices Connecting
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
GPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone
E-Mon Communication Gateway Utility Instructions for BACnet/mstp
E-Mon Communication Gateway Utility Instructions for BACnet/mstp The E-Mon Communication Gateway utility will allow you to configure the Device Instance (Node ID) and other parameters needed for your BACnet/mstp
GV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-A
M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0
M72 Quectel Cellular Engine EVB User Guide M72_EVB_UGD_V1.0 Document Title EVB User Guide Version 1.0 Date 2011-05-18 Status Document Control ID Release M72_EVB_UGD_V1.0 General Notes Quectel offers this
Home Wi-Fi Gateway Instructions
Home Wi-Fi Gateway Instructions 1. Connect the gateway. Use the coaxial cable provided by BendBroadband to connect the cable port (A) to your cable outlet. 2. Connect your computer to the cable modem gateway
xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide
xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide Part Number 900-685 Revision A June 2013 Copyright and Trademark Contacts 2013 Lantronix, Inc.. All rights reserved. No part of the contents
HandPunch. Overview. Biometric Recognition. Installation. Is it safe?
HandPunch Overview Biometric Recognition Installation This section describes the HandPunch series of biometric scanners from RSI (Recognition Systems). These instructions apply to all the different HandPunch
Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.
IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input