1 Bioinstrumentation Medical Instrumentation: Application and Design Third Edition John G. Webster, Editor Kuo-Sheng Cheng, Ph.D. Department of Biomedical Engineering National Cheng Kung University

2 The Importance of Medical Instrumentation Diagnosis and therapy depend heavily on the use of medical instrumentation. Medical procedures: Medicine can be defined as a multistep procedure on an individual by a physician, group of physician, or an institute, repeated until the symptoms disappear.

3 The Importance of Medical Medical procedure Instrumentation 1) Collection of data - qualitative and/or quantitative 2) Analysis of data 3) Decision making 4) Treatment planning based on the decision 5) Repeat

4 A Story of New Medical Device The invention, prototype design, product development, clinical testing, regulatory approval, manufacturing, marketing, and sale of a new medical instrument add up a complex, expensive, and lengthy process. A success story - Technicon s Auto Analyzer

5 Development of Technicon s Auto Analyzer The inventor - Leonard Skeggs, Chair of Department of Pathology at Case Western Reserve University - Dr. Alan Moritz Technicon Corporation founders - Edwin C. Whitehead, and his father a four-page confidential disclosure form

6 Development of Technicon s Auto Analyzer Two key persons to recall the invention - Technicon s only salesman, Ray Roesch, and the doctor at the Cleveland Veterans Adminstration Hospital, Joseph Kahn. Patent application and protection Marketing strategy

7 Development of Technicon s Auto Analyzer Factors affected the success it allows an enormous improvement in quality of laboratory test results, and an enormous reduction in the cost of doing chemical analysis. accurate laboratory data are useful in diagnosis. reimbursement policies increase the availability of health care.

8 Evolutionary product v.s. Revolutionary product Generalized medical instrumentation system measurand sensor signal conditioning output display auxiliary elements

9 Control And feedback Sensor Power source Measurand Primary Sensing element Variable Conversion element Signal processing Output display Perceptible output Calibration signal Data storage Data transmission Radiation, electric current, or other applied energy Figure 1.1 Generalized instrumentation

10

11

12 Alternative Operational Modes Direct-Indirect modes Sampling and Continuous modes Generating and Modulating sensors Analog and Digital Modes Real-time and Delayed-time Modes

13 Medical Measurement Constraints Many crucial variables in living systems are inaccessible. Variables measured are seldom deterministic. Nearly all biomedical measurements depend on the energy. Operation of instruments in the medical environment imposes important additional constraints.

14 Classifications of Biomedical Instruments The sensed quantity The principle of transduction The organ system for measurement The clinical medicine specialities

15 Classifications of Biomedical Instruments Based on the activities involved in the medical care, medical instrumentation may be divided into three categories: diagnostic devices therapeutic devices monitoring devices

16 Generalized Static Characteristics Accuracy Precision Resolution Reproducibility Statistical control Static sensitivity, Sensitivity drift Zero drift Linearity

17 Characteristic with zero and sensitivity drift y (Output) Total error due to drift y (Output) D y' + Sensitivity drift D x' d - Zero drift Intercept b Dx d Dy Slope m = Dy Dx d + Zero drift - Sensitivity drift y = mx d + b x d (Input) x d (Input) (a) (b) Figure 1.3 (a) Static-sensitivity curve that relates desired input x d to output y. Static sensitivity may be constant for only a limited range of inputs. (b) Static sensitivity: zero drift and sensitivity drift. Dotted lines indicate that zero drift and sensitivity drift can be negative.

18 Generalized Static Characteristics Input ranges Input impedance

19 Generalized Dynamic Characteristics Differential or Integral equations Transfer functions Time delay

20 Figure 1.8 Design process for medical instruments Choice and design of instruments are affected by signal factors, and also by environmental, medical, and economic factors.

21 Regulation of Medical Devices Medical Device Amendments to the Federal Food, Drug, and Cosmetics Act Safe Medical Devices Act Medical Device: any item promoted for a medical purpose that does not rely on chemical action to achieve its intended effect

22 Regulation of Medical Devices Medical devices were classified in two ways: Class I (general controls), Class II (performance standards), and Class III (premarketing approval) Preamendment, Postamendment, Substantially equivalent, implant, custom, investigation, and transitional.

23

24

25 Biomedical Transducer Measuring is the key to understand, and transducer plays an important role in measurement. Kuo-Sheng Cheng, Ph.D. Institute of Biomedical Engineering National Cheng Kung University

26 What is the Transducers? In principle, Transducers are devices that convert signals in one form of energy into signals in another form of energy. Sensors Actuator Conventional v.s. Intelligent Transducers

27 What are the Transduers, Sensors, and Actuators? Transducer - A device that converts energy of one form to another. Sensor - A device that converts a physical parameter to an electric output. Actuator - A device that converts an electric signal to a physical output.

28 Conventional v.s. Intelligent Transducer Conventional transducer Physical or Chemical Parameters Sensor Transmission Link Signal Processing Display Storage Actuator... Further Processing

29 Conventional v.s. Intelligent Intelligent transducer Transducer Physical or Chemical Parameters Sensing Element & Signal Processing Transmission Link Signal Processing Display Storage Actuator... Further Processing

30 Transducer Categories By application By physical or chemical principles used By the process used to convert the signal energy into an electrical signal

31 Three types of output signal Self-generating (active) transducers: The electrical signal output of transducer is generated from another form of input energy. e.g. Light in ~ I R L Electrical Signal Output Photovoltaic cell

32 Three types of output signal Modulating (passive) transducer: The input signal energy of transducer is used to modulate the electrical energy flow from the power supply to the transducer output. e.g. Light in I R L Electrical Signal Output Photoconductive cell

33 Three types of output signal Tandem transducers: e.g. Light in The original input signal energy is converted to a final output of electrical energy through two or three effects or conversions in tandem. Modulated light Y-position Photoconductive cell I R L Electrical Signal Output

34 1. Sensor characteristics 2. Physical Sensors Displacement measurements Resistive Capacitive Inductive Piezoelectric Temperature measurements Optical measurements 3. Chemical Sensors Biochemical

35 Electronic Sphygmomanometer The System Design & Analysis Student: Cheng-Yu Chen Advisor: Kuo-Sheng Cheng Biomedical Imaging & Instrumentation Lab

36 Introduction The blood pressure measurement -Invasive method Stephen Hales placed a glass tube in the artery of horse for blood pressure measurement in The measurement of blood pressure with a mercury sphygmomanometer was first invented by J. M. Poiseuille in Noninvasive method Limb-occluding device that contained an arm cuff was first invented by S. Riva-Rocci in L. Hill and H. Barnard published a modified sphygmomanometer with cuff in N. S. Korotkov invented an auscultatory measurement of systolic and diastolic blood pressure in 1905.

37 Introduction (cont.) Stephen Hales demonstrated the blood pressure in horse in 1733.

38 Introduction (cont.) Riva-Rocci s sphygmomanometer, 1896 Blood pressure measurement using Korotkov s method, 1905 *E. O Brien and D. Fitzgerald, The history of indirect blood pressure measurement, Handbook of Hypertension, Vol. 14: Blood Pressure Measurement

39 Korotkov s method Introduction (cont.)

40 Introduction (cont.) The oscillometric method

41 System Description RS-232 Data transmission Display unit Analog signal processing Circuits Microprocessor with A/D converter Pressure Signal Low-Pass Filter High-Pass Filter Instrumentation Amplifier Air pump & valve control circuit Cuff Pressure Sensor

42 The system circuits Hardware Design Display Unit Microprocessor With A/D Converter Pressure Sensor Analog Signal Processing Circuit RS-232 Data Transmission Air Pump & Valve Control Circuit

Understanding Dynamic Range in Acceleration Measurement Systems. February 2013 By: Bruce Lent

Understanding Dynamic Range in Acceleration Measurement Systems. February 2013 By: Bruce Lent in Acceleration Measurement Systems February 2013 By: Bruce Lent Topics to discuss Definition of dynamic range The effective range Making full use of the high level Using filters to improve dynamic range

More information

OEM MAXNIBP Frequently Asked Questions

OEM MAXNIBP Frequently Asked Questions Frequently Asked Questions Why does the monitor sometimes inflate the BP cuff, then shortly thereafter reinflate the cuff? How will I know if the monitor is experiencing motion artifact during a measurement?

More information

Fundamentals of Mass Flow Control

Fundamentals of Mass Flow Control Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of

More information

Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology

Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology Application Note for SDP600 and SDP1000 Series Measuring Differential Pressure and Air Volume with Sensirion s CMOSens technology Summary The increasing customer requirements for comfort and safety and

More information

CALIBRATION PRINCIPLES

CALIBRATION PRINCIPLES 1 CALIBRATION PRINCIPLES After completing this chapter, you should be able to: Define key terms relating to calibration and interpret the meaning of each. Understand traceability requirements and how they

More information

ELECTRICAL ENGINEERING

ELECTRICAL ENGINEERING EE ELECTRICAL ENGINEERING See beginning of Section H for abbreviations, course numbers and coding. The * denotes labs which are held on alternate weeks. A minimum grade of C is required for all prerequisite

More information

Practical Application of Industrial Fiber Optic Sensing Systems

Practical Application of Industrial Fiber Optic Sensing Systems Practical Application of Industrial Fiber Optic Sensing Systems John W. Berthold and David B. Needham Davidson Instruments, Inc. P.O. Box 130100, The Woodlands, TX 77393 ABSTRACT In this presentation,

More information

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article F e a t u r e A r t i c l e Feature Article Development of a High Accuracy, Fast Response Mass Flow Module Utilizing Pressure Measurement with a Laminar Flow Element (Resistive Element) Criterion D200

More information

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University Principles of Medical Ultrasound Pai-Chi Li Department of Electrical Engineering National Taiwan University What is Medical Ultrasound? Prevention: actions taken to avoid diseases. Diagnosis: the process

More information

Buffer Op Amp to ADC Circuit Collection

Buffer Op Amp to ADC Circuit Collection Application Report SLOA098 March 2002 Buffer Op Amp to ADC Circuit Collection Bruce Carter High Performance Linear Products ABSTRACT This document describes various techniques that interface buffer op

More information

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

ε: Voltage output of Signal Generator (also called the Source voltage or Applied Experiment #10: LR & RC Circuits Frequency Response EQUIPMENT NEEDED Science Workshop Interface Power Amplifier (2) Voltage Sensor graph paper (optional) (3) Patch Cords Decade resistor, capacitor, and

More information

INTRODUCTION TO SENSORS AND ACTUATORS

INTRODUCTION TO SENSORS AND ACTUATORS Summer 2015 INTRODUCTION TO SENSORS AND ACTUATORS This course is an elective and will be offered as an undergraduate/graduate class. If you require a more detailed outline or any additional information,

More information

Analog Signal Conditioning

Analog Signal Conditioning Analog Signal Conditioning Analog and Digital Electronics Electronics Digital Electronics Analog Electronics 2 Analog Electronics Analog Electronics Operational Amplifiers Transistors TRIAC 741 LF351 TL084

More information

Section 3. Sensor to ADC Design Example

Section 3. Sensor to ADC Design Example Section 3 Sensor to ADC Design Example 3-1 This section describes the design of a sensor to ADC system. The sensor measures temperature, and the measurement is interfaced into an ADC selected by the systems

More information

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS Many mechanical energy systems are devoted to transfer of energy between two points: the source or prime mover (input) and the load (output). For chemical

More information

JOURNAL OF MEDICAL INFORMATICS & TECHNOLOGIES Vol. 21/2012, ISSN 1642-6037

JOURNAL OF MEDICAL INFORMATICS & TECHNOLOGIES Vol. 21/2012, ISSN 1642-6037 JOURNAL OF MEDICAL INFORMATICS & TECHNOLOGIES Vol. 21/2012, ISSN 1642-6037 FDA, medical software, recall, safety of medical devices. Leszek DREWNIOK 1, Ewelina PIEKAR 1, Mirosław STASIAK 1, Remigiusz MANIURA

More information

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity 1 Lecture 5 Hemodynamics Description of fluid flow Hydrodynamics is the part of physics, which studies the motion of fluids. It is based on the laws of mechanics. Hemodynamics studies the motion of blood

More information

3 rd Russian-Bavarian Conference on Bio-Medical Engineering

3 rd Russian-Bavarian Conference on Bio-Medical Engineering 3 rd Russian-Bavarian Conference on Bio-Medical Engineering Blood Pressure Estimation based on Pulse Transit Time and Compensation of Vertical Position Dipl.-Inform. Med. Christian Douniama Dipl.-Ing.

More information

The Shifting Sands of Medical Software Regulation

The Shifting Sands of Medical Software Regulation The Shifting Sands of Medical Software Regulation Suzanne O Shea Ralph Hall September 10, 2014 What Software is Regulated by FDA? FDA regulates medical devices. FDA regulates software that meets the definition

More information

Pressure Transducer to ADC Application

Pressure Transducer to ADC Application Application Report SLOA05 October 2000 Pressure Transducer to ADC Application John Bishop ABSTRACT Advanced Analog Products/OpAmp Applications A range of bridgetype transducers can measure numerous process

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully

More information

Relationship between large subject matter areas

Relationship between large subject matter areas H02M APPARATUS FOR CONVERSION BETWEEN AC AND AC, BETWEEN AC AND DC, OR BETWEEN DC AND DC, AND FOR USE WITH MAINS OR SIMILAR POWER SUPPLY SYSTEMS; CONVERSION OF DC OR AC INPUT POWER INTO SURGE OUTPUT POWER;

More information

How To Calculate The Power Gain Of An Opamp

How To Calculate The Power Gain Of An Opamp A. M. Niknejad University of California, Berkeley EE 100 / 42 Lecture 8 p. 1/23 EE 42/100 Lecture 8: Op-Amps ELECTRONICS Rev C 2/8/2012 (9:54 AM) Prof. Ali M. Niknejad University of California, Berkeley

More information

Basic RTD Measurements. Basics of Resistance Temperature Detectors

Basic RTD Measurements. Basics of Resistance Temperature Detectors Basic RTD Measurements Basics of Resistance Temperature Detectors Platinum RTD resistances range from about 10 O for a birdcage configuration to 10k O for a film type, but the most common is 100 O at 0

More information

22.302 Experiment 5. Strain Gage Measurements

22.302 Experiment 5. Strain Gage Measurements 22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified

More information

Sensors Collecting Manufacturing Process Data

Sensors Collecting Manufacturing Process Data Sensors & Actuators Sensors Collecting Manufacturing Process Data Data must be collected from the manufacturing process Data (commands and instructions) must be communicated to the process Data are of

More information

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor)

Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor) Experiment #11: LRC Circuit (Power Amplifier, Voltage Sensor) Concept: circuits Time: 30 m SW Interface: 750 Windows file: RLC.SWS EQUIPMENT NEEDED Science Workshop Interface Power Amplifier (2) Voltage

More information

LAB#5 STATIC WEIGHT SCALE CALIBRATION ELECTROMECHANICAL ANALYSIS LAB EMET 3424_70 TUESDAY, FEBUARY 27, 2001 8:00 9:50AM, SET 363

LAB#5 STATIC WEIGHT SCALE CALIBRATION ELECTROMECHANICAL ANALYSIS LAB EMET 3424_70 TUESDAY, FEBUARY 27, 2001 8:00 9:50AM, SET 363 ELECTROMECHANICAL ANALYSIS LAB EMET 3424_70 TUESDAY, FEBUARY 27, 2001 8:00 9:50AM, SET 363 LAB#5 STATIC WEIGHT SCALE CALIBRATION PREPARER: Scott Greenberg Address: Mac S J5C4 Phone: 607-587-2615 E-mail:

More information

M.S Ramaiah School of Advanced Studies - Bangalore. On completion of this session, the delegate will understand and be able to appriciate:

M.S Ramaiah School of Advanced Studies - Bangalore. On completion of this session, the delegate will understand and be able to appriciate: Transmission Control Lecture delivered by: Prof. Ashok C.Meti MSRSAS-Bangalore 1 Session Objectives On completion of this session, the delegate will understand and be able to appriciate: Rl Role of electronic

More information

INTREPID Perimeter Intrusion Detection System

INTREPID Perimeter Intrusion Detection System TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.

More information

Perimeter Security System

Perimeter Security System TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated

More information

REMOTE ELECTROCARDIOGRAM MONITORING BASED ON THE INTERNET

REMOTE ELECTROCARDIOGRAM MONITORING BASED ON THE INTERNET REMOTE ELECTROCARDIOGRAM MONITORING BASED ON THE INTERNET Khalid Mohamed Alajel*, Khairi Bin Yosuf, Abdul Rhman Ramli, El Sadig Ahmed Department of Computer & Communication System Engineering Faculty of

More information

MECE 102 Mechatronics Engineering Orientation

MECE 102 Mechatronics Engineering Orientation MECE 102 Mechatronics Engineering Orientation Mechatronic System Components Associate Prof. Dr. of Mechatronics Engineering Çankaya University Compulsory Course in Mechatronics Engineering Credits (2/0/2)

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E. By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt

More information

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER W. Li, J. Vandewege Department of Information Technology (INTEC) University of Gent, St.Pietersnieuwstaat 41, B-9000, Gent, Belgium Abstract: Precision

More information

April 3, 2015. Dear Autumn Liu,

April 3, 2015. Dear Autumn Liu, DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 April 3, 2015 Shenzhen

More information

Sophomore Physics Laboratory (PH005/105)

Sophomore Physics Laboratory (PH005/105) CALIFORNIA INSTITUTE OF TECHNOLOGY PHYSICS MATHEMATICS AND ASTRONOMY DIVISION Sophomore Physics Laboratory (PH5/15) Analog Electronics Active Filters Copyright c Virgínio de Oliveira Sannibale, 23 (Revision

More information

TERMINOLOGY USED IN INSTRUMENT ACCURACY Rick Williams Rawson & Co., Inc.

TERMINOLOGY USED IN INSTRUMENT ACCURACY Rick Williams Rawson & Co., Inc. TERMINOLOGY USED IN INSTRUMENT ACCURACY Rick Williams Rawson & Co., Inc. P.O. Box 924288, Houston, TX 77292 The purpose of this paper is to offer a brief explanation and discussion of many key terms used

More information

Higher National Unit Specification. General information for centres. Transmission of Measurement Signals. Unit code: DX4T 35

Higher National Unit Specification. General information for centres. Transmission of Measurement Signals. Unit code: DX4T 35 Higher National Unit Specification General information for centres Unit title: Transmission of Measurement Signals Unit code: DX4T 35 Unit purpose: This Unit is designed to enable candidates to gain knowledge

More information

What Does Having a FDA Cleared Pregnancy Test Mean?

What Does Having a FDA Cleared Pregnancy Test Mean? What Does Having a FDA Cleared Pregnancy Test Mean? Clinical Trials Transformation Initiative (CTTI) July 15-16, 2013 Denise N. Johnson-Lyles, Ph.D. Toxicology Branch Chief Division of Chemistry and Toxicology

More information

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS POSITION DETECTION FOR MACHINE TOOL CLAMP OPTIMIZING THE TOOL CLAMPING PROCESS The core of a

More information

Force/position control of a robotic system for transcranial magnetic stimulation

Force/position control of a robotic system for transcranial magnetic stimulation Force/position control of a robotic system for transcranial magnetic stimulation W.N. Wan Zakaria School of Mechanical and System Engineering Newcastle University Abstract To develop a force control scheme

More information

# 2. Selecting and Using Thermistors for Temperature Control

# 2. Selecting and Using Thermistors for Temperature Control # 2 Selecting and Using Thermistors for Temperature Control Selecting and Using Thermistors for Temperature Control Thermally sensitive resistors (thermistors) are used widely in laser diode and detector

More information

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give

More information

dspace DSP DS-1104 based State Observer Design for Position Control of DC Servo Motor

dspace DSP DS-1104 based State Observer Design for Position Control of DC Servo Motor dspace DSP DS-1104 based State Observer Design for Position Control of DC Servo Motor Jaswandi Sawant, Divyesh Ginoya Department of Instrumentation and control, College of Engineering, Pune. ABSTRACT This

More information

Poznan University of Technology Faculty of Electrical Engineering

Poznan University of Technology Faculty of Electrical Engineering Poznan University of Technology Faculty of Electrical Engineering Contact Person: Pawel Kolwicz Vice-Dean Faculty of Electrical Engineering pawel.kolwicz@put.poznan.pl List of Modules Academic Year: 2015/16

More information

Sensor Performance Metrics

Sensor Performance Metrics Sensor Performance Metrics Michael Todd Professor and Vice Chair Dept. of Structural Engineering University of California, San Diego mdtodd@ucsd.edu Email me if you want a copy. Outline Sensors as dynamic

More information

Engineering Standards Advance PAT

Engineering Standards Advance PAT Engineering Standards Advance PAT By Manuel Hormaza, CEO and Founder, IBS Caribe We often look at PAT as a limited initiative, usually with a focus on a regulatory mandate and a possible break to speed

More information

Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems

Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems PHOTODIODE VOLTAGE SHORT-CIRCUIT PHOTODIODE SHORT- CIRCUIT VOLTAGE 0mV DARK ark By Luis Orozco Introduction Precision

More information

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES 191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of

More information

Op Amp Circuit Collection

Op Amp Circuit Collection Op Amp Circuit Collection Note: National Semiconductor recommends replacing 2N2920 and 2N3728 matched pairs with LM394 in all application circuits. Section 1 Basic Circuits Inverting Amplifier Difference

More information

Pressure Sensor Based Estimation of Pulse Transit Time

Pressure Sensor Based Estimation of Pulse Transit Time International Journal of Information & Computation Technology. ISSN 0974-2239 Volume 4, Number 13 (2014), pp. 1321-1328 International Research Publications House http://www. irphouse.com Pressure Sensor

More information

Power Measurement in Cycling using inductive Coupling of Energy and Data (P80)

Power Measurement in Cycling using inductive Coupling of Energy and Data (P80) Power Measurement in Cycling using inductive Coupling of Energy and Data (P80) Reinhardt Tielert, Norbert Wehn 1, Thomas Jaitner 2, Roland Volk 1 Topics: Bicycle; Innovation & Design; Measurement Systems;

More information

Teaching the Importance of Data Correlation in Engineering Technology

Teaching the Importance of Data Correlation in Engineering Technology Session 3549 Teaching the Importance of Data Correlation in Engineering Technology Michael R. Warren, Dana M. Burnett, Jay R. Porter, and Rainer J. Fink Texas A&M University Abstract To meet the needs

More information

HM1500LF Relative Humidity Module

HM1500LF Relative Humidity Module Small size product Product free from Lead, Cr(6+), Cd and Hg Humidity calibrated within +/-2% @55%RH Typical 1 to 3.6 Volt DC output for 0 to 100% RH at 5Vdc supply Ratiometric to voltage supply from 4.75Vdc

More information

Medical Device Design: Shorten Prototype and Deployment Time with NI Tools. NI Technical Symposium 2008

Medical Device Design: Shorten Prototype and Deployment Time with NI Tools. NI Technical Symposium 2008 Medical Device Design: Shorten Prototype and Deployment Time with NI Tools NI Technical Symposium 2008 FDA Development Cycle From Total Product Life Cycle by David W. Fiegal, M.D., M.P.H. FDA CDRH Amazon.com

More information

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace. SAFETY Industrial DESCRIBE hazards and precautions taken to avoid injury in the workplace. Example #1: All of the following are common PPE used to perform maintenance activities EXCEPT: a. Safety Glasses

More information

Vasc Health Risk Manag. 2011; 7: 709 717. Published online 2011 November 30. doi: 10.2147/VHRM.S27193 PMCID: PMC3237100

Vasc Health Risk Manag. 2011; 7: 709 717. Published online 2011 November 30. doi: 10.2147/VHRM.S27193 PMCID: PMC3237100 Vasc Health Risk Manag. 2011; 7: 709 717. Published online 2011 November 30. doi: 10.2147/VHRM.S27193 PMCID: PMC3237100 Validation of four automatic devices for self-measurement of blood pressure according

More information

The Development of a Pressure-based Typing Biometrics User Authentication System

The Development of a Pressure-based Typing Biometrics User Authentication System The Development of a Pressure-based Typing Biometrics User Authentication System Chen Change Loy Adv. Informatics Research Group MIMOS Berhad by Assoc. Prof. Dr. Chee Peng Lim Associate Professor Sch.

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

Solution 1: Algorithm Positioning

Solution 1: Algorithm Positioning Model No: OEAFP Series All-Fiber Pipeline Security System Solutions Solution 1: Algorithm Positioning Application conditions Applicable for outdoor long-distance oil-gas pipeline security monitoring without

More information

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: 1-800-447-IABP (4227)

FiberOptix TM. AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE. U.S. and Canada: 1-800-447-IABP (4227) FiberOptix TM AP Sensor Zeroing and Calibration Guide INTRA-AORTIC BALLOON PRODUCT SUPPORT HOTLINE U.S. and Canada: 1-800-447-IABP (4227) Worldwide: 617-389-8628 Caution: U.S. Federal Law limits this device

More information

Meeting TeTech. Version: 1.8, 15-July-2013, Author: Wim Telkamp, language: English

Meeting TeTech. Version: 1.8, 15-July-2013, Author: Wim Telkamp, language: English Meeting TeTech, English version TeTech M.H. Trompstraat 6 3601 HT Maarssen The Netherlands Tel: + 31 (0) 346 284004 Fax: + 31 (0) 346 283691 Email: info@tetech.nl Web: www.tetech.nl CoC: 30169033 VAT:

More information

FDA Regulation of Whole Slide Imaging (WSI) Devices: Current Thoughts

FDA Regulation of Whole Slide Imaging (WSI) Devices: Current Thoughts FDA Regulation of Whole Slide Imaging (WSI) Devices: Current Thoughts Clinical Laboratory Improvement Advisory Committee Meeting Centers for Disease Control and Prevention February 15, 2012 Tremel A. Faison,

More information

Michael Hiebel. Fundamentals of Vector Network Analysis

Michael Hiebel. Fundamentals of Vector Network Analysis Michael Hiebel Fundamentals of Vector Network Analysis TABIH OF CONTENTS Table of contents 1 Introduction 12 1.1 What is a network analyzer? 12 1.2 Wave quantities and S-parameters 13 1.3 Why vector network

More information

Gas Custody Transfer Calibration

Gas Custody Transfer Calibration Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform

More information

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM

Hemodynamic Monitoring: Principles to Practice M. L. Cheatham, MD, FACS, FCCM SUMMARY HEMODYNAMIC MONITORING: FROM PRINCIPLES TO PRACTICE Michael L. Cheatham, MD, FACS, FCCM Director, Surgical Intensive Care Units Orlando Regional Medical Center Orlando, Florida Fluid-filled catheters

More information

CONNECTING LESSONS NGSS STANDARD

CONNECTING LESSONS NGSS STANDARD CONNECTING LESSONS TO NGSS STANDARDS 1 This chart provides an overview of the NGSS Standards that can be met by, or extended to meet, specific STEAM Student Set challenges. Information on how to fulfill

More information

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003

Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003 Direct Arterial Blood Pressure Monitoring Angel M. Rivera CVT, VTS (ECC) Animal Emergency Center Glendale, WI March 2003 Introduction Direct measurement of arterial blood pressure is obtained via a peripheral

More information

EP 2 492 881 A2 (19) (11) EP 2 492 881 A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: 29.08.2012 Bulletin 2012/35

EP 2 492 881 A2 (19) (11) EP 2 492 881 A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: 29.08.2012 Bulletin 2012/35 (19) (12) EUROPEAN PATENT APPLICATION (11) EP 2 492 881 A2 (43) Date of publication: 29.08.2012 Bulletin 2012/35 (51) Int Cl.: G08B 13/16 (2006.01) G08B 25/08 (2006.01) (21) Application number: 12386006.6

More information

High Voltage Power Supplies for Analytical Instrumentation

High Voltage Power Supplies for Analytical Instrumentation ABSTRACT High Voltage Power Supplies for Analytical Instrumentation by Cliff Scapellati Power supply requirements for Analytical Instrumentation are as varied as the applications themselves. Power supply

More information

Procon Engineering. Technical Document PELR 1002. TERMS and DEFINITIONS

Procon Engineering. Technical Document PELR 1002. TERMS and DEFINITIONS Procon Engineering Technical Document PELR 1002 TERMS and DEFINITIONS The following terms are widely used in the weighing industry. Informal comment on terms is in italics and is not part of the formal

More information

O&M Service for Megasolar Power Plants and Precise Monitoring Techniques for PV Modules

O&M Service for Megasolar Power Plants and Precise Monitoring Techniques for PV Modules 403 Hitachi Review Vol. 63 (2014), No. 7 Featured Articles O&M Service for Megasolar Power Plants and Precise Monitoring Techniques for PV Modules Tohru Kohno Tetsuharu Ohya Tomoharu Nakamura OVERVIEW:

More information

Air Conditioning System

Air Conditioning System Air Conditioning System 1 Chonan Technical Service Training Center Chonan Technical Service Training Center 2 Objectives To understand the components of air conditioning system. To understand the control

More information

Electrocardiogram (ECG) Monitoring System using Bluetooth technology

Electrocardiogram (ECG) Monitoring System using Bluetooth technology Electrocardiogram (ECG) Monitoring System using Bluetooth technology Zarina Md Amin, Suryani Ilias, Zunuwanas Mohamad Department of Electrical Engineering, Polytechnic of Sultan Abdul Salahuddin Abdul

More information

Biomedical Engineering Department Cornell University

Biomedical Engineering Department Cornell University Biomedical Engineering Department Cornell University Our department offers three degree programs. The PhD is a research degree which usually requires approximately 5 years depending on the success of the

More information

Content Map For Career & Technology

Content Map For Career & Technology Content Strand: Applied Academics CT-ET1-1 analysis of electronic A. Fractions and decimals B. Powers of 10 and engineering notation C. Formula based problem solutions D. Powers and roots E. Linear equations

More information

Unsteady Pressure Measurements

Unsteady Pressure Measurements Quite often the measurements of pressures has to be conducted in unsteady conditions. Typical cases are those of -the measurement of time-varying pressure (with periodic oscillations or step changes) -the

More information

Introduction. Chapter 1. 1.1 Scope of Electrical Engineering

Introduction. Chapter 1. 1.1 Scope of Electrical Engineering Chapter 1 Introduction 1.1 Scope of Electrical Engineering In today s world, it s hard to go through a day without encountering some aspect of technology developed by electrical engineers. The impact has

More information

Module 1, Lesson 3 Temperature vs. resistance characteristics of a thermistor. Teacher. 45 minutes

Module 1, Lesson 3 Temperature vs. resistance characteristics of a thermistor. Teacher. 45 minutes Module 1, Lesson 3 Temperature vs. resistance characteristics of a thermistor 45 minutes Teacher Purpose of this lesson How thermistors are used to measure temperature. Using a multimeter to measure the

More information

CRITERIA FOR ACCREDITING ENGINEERING TECHNOLOGY PROGRAMS

CRITERIA FOR ACCREDITING ENGINEERING TECHNOLOGY PROGRAMS CRITERIA FOR ACCREDITING ENGINEERING TECHNOLOGY PROGRAMS Effective for Reviews During the 2013-2014 Accreditation Cycle Incorporates all changes approved by the ABET Board of Directors as of October 27,

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

UNIVERSITY OF OULU. Department of Electrical Engineering (EE)

UNIVERSITY OF OULU. Department of Electrical Engineering (EE) UNIVERSITY OF OULU Department of Electrical Engineering (EE) University of Oulu Founded in 1958 6 faculties 16 000 students 2900 employees Total funding EUR 226 million Among the largest universities in

More information

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY Breakout Session 3B Tuesday, May 1 8:30 10 am James Blackwood, MS, CLSI David D. Koch, PhD, FACB, DABCC, Pathology & Laboratory

More information

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

Note: This information obtained from internet sources and not verified- use at your own risk!!!! Cummins Engine Diagnostic Fault Codes for 2003 and later engines (generally for 2004 and later Alpines; see page 13 for earlier engine diagnostic codes): Note: This information obtained from internet sources

More information

ELECTRICAL AND COMPUTER ENGINEERING By Joan Omoruyi, Engineering Librarian, Northeastern University

ELECTRICAL AND COMPUTER ENGINEERING By Joan Omoruyi, Engineering Librarian, Northeastern University ELECTRICAL AND COMPUTER ENGINEERING By Joan Omoruyi, Engineering Librarian, Northeastern University. Soon after physicists began to understand electricity, the electrical engineering profession was born

More information

Hand Gestures Remote Controlled Robotic Arm

Hand Gestures Remote Controlled Robotic Arm Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 3, Number 5 (2013), pp. 601-606 Research India Publications http://www.ripublication.com/aeee.htm Hand Gestures Remote Controlled

More information

FDA Regulation of Health IT

FDA Regulation of Health IT FDA Regulation of Health IT September 2014 Marian J. Lee Partner +1 (202) 661 7955 mlee@kslaw.com Agenda FDA s Mobile Medical Applications Guidance FDA Draft Guidance on Medical Device Data Systems (MDDS),

More information

E0-245: ASP. Lecture 16+17: Physical Sensors. Dipanjan Gope

E0-245: ASP. Lecture 16+17: Physical Sensors. Dipanjan Gope E0-245: ASP Lecture 16+17: Physical Sensors Module 2: Android Sensor Applications Location Sensors - Theory of location sensing - Package android.location Physical Sensors - Sensor Manager - Accelerometer

More information

High speed infrared camera for contactless temperature measurement on rotating tires

High speed infrared camera for contactless temperature measurement on rotating tires DIAS Infrared GmbH Publications No. 9 1 High speed infrared camera for contactless temperature measurement on rotating tires Helmut Budzier, Dresden University of Technology, Institute for Solid-State

More information

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY A. 510(k) Number: k103555 B. Purpose for Submission: New submission C. Measurand: Platelet aggregation D. Type of Test: Platelet aggregometer

More information

Experiment #1, Analyze Data using Excel, Calculator and Graphs.

Experiment #1, Analyze Data using Excel, Calculator and Graphs. Physics 182 - Fall 2014 - Experiment #1 1 Experiment #1, Analyze Data using Excel, Calculator and Graphs. 1 Purpose (5 Points, Including Title. Points apply to your lab report.) Before we start measuring

More information

Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current

Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current Summary Dually Fed Permanent Magnet Synchronous Generator Condition Monitoring Using Stator Current Joachim Härsjö, Massimo Bongiorno and Ola Carlson Chalmers University of Technology Energi och Miljö,

More information

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE S.Josephine Selvarani ECE Department, Karunya University, Coimbatore. Abstract - An on-line health monitoring of physiological signals of humans such as temperature

More information

Certificate: 0000038506 / 20 August 2013

Certificate: 0000038506 / 20 August 2013 Test report: 936/21219899/B of 28 March 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 1.1 Approved application The tested AMS

More information

Analog signals are those which are naturally occurring. Any analog signal can be converted to a digital signal.

Analog signals are those which are naturally occurring. Any analog signal can be converted to a digital signal. 3.3 Analog to Digital Conversion (ADC) Analog signals are those which are naturally occurring. Any analog signal can be converted to a digital signal. 1 3.3 Analog to Digital Conversion (ADC) WCB/McGraw-Hill

More information

Clinical Decision Support Systems. Dr. Adrian Mondry

Clinical Decision Support Systems. Dr. Adrian Mondry Clinical Decision Support Systems Dr. Adrian Mondry Medical practice is decision making! Types of decisions in medicine: Diagnosis Diagnostic process Management of treatment Resource management in a hospital

More information