Sound pr. (db(a)) Phone: Pressure hpa Fax: Capacity kw
|
|
- Morris Sullivan
- 8 years ago
- Views:
Transcription
1 Hybrid-Re-Cooler V-2x8 - Offer no Sound power (db(a)) Sound pr. (db(a)) Company Schenkel & Partner GmbH 1 Branch Ingenieurbüro Street Bahnhofstrasse 44 Country/ZIP/City 8 Zürich Installation Credit Suisse 8 Project Zentrale Kälte Project leader P. Kaltenrieder 6 Height m 4 Pressure hpa 967 Capacity kw 1 Present surface m Sound power db(a) Periphery m Istanbul, Sound pr. db(a) Volume flow humid m3/h Definition: Temp. C Stepless controls Definition: Rel. humidity Speed () Fan Piece Volume flow m3/h Static pressure (Pa) Heat exchanger 9 9. Pressure drop (Pa) Box. Heat exchanger Pa Box Pa.44 Length mm 478. Width mm 2 1 Height mm Weight empty kg 6. Volume kg Weight total kg Fan: Ziehl-Abegg Type FE8-SD.6N.V7.Δ Diameter mm 8 1 Speed rpm 9 1 Fan: Volume flow (m3/h) Sound power db(a) 84. Capacity (~V-3.7A-Hz) W Container: 23 x 2292 x 89 (") x 129 (") Volume flow m3/h Static pressure Pa Et.glycol m3/h Temp. in C 34. Temp. out C 28. Connections // mm 2 x NW1 L 2 Fill water requirement: 9.16 less than a open-cooling-tower! Air Inlet --- Outlet Temp. C Rel. humidity Abs. humidity g/kg Density humid kg/m Enthalpy humid kj/kg Mass flow dry kg/h Volume flow humid m3/h Humidification C Humidification m3/h Humidification (Max.) m3/h Indication Piece Remarks Weight EUR Heat exchanger 2 Type /3/16-6R-44T-A-3.PA-132C Pump 3.9 m3/h 1 Humidification Waste water.281 m3/h 6 6 Fan, motor à 18 W 16 Ziehl-Abegg, FE8-SD.6N.V7.Δ Construction type 1 Galvanized Stepless controls 1 Basic equipment, controls 9 Delivery 9- weeks Total Validity 12 weeks Discount Conditions net, prepaid adress Payment days net Price net:
2 RU G LH RH RO Type /3/16-6R-44T-A-3.PA-132C Capacity kw sensible:.461 Surface reserve.46 latent: Present surface m Required surface m Heat transfer coefficient W/m2K ffi:.e- Mean temp. diff. ( ) K 6.31 ffa:.e- Air humid Inlet Outlet Definition Height over sea level m 4 Pressure hpa 967 Temp. ( 31. ) C Rel. humidity ( 46.9 ) Istanbul, Abs. humidity ( ) g/kg Density humid kg/m Enthalpy humid kj/kg Volume flow humid m3/h Mass flow dry kg/h Velocity m/s Pressure drop (dry 72 Pa) Pa Humidification C Humidification m3/h Et.glycol Inlet Outlet Medium Temp. C Density kg/m Heat cont. kj/kgk Heat cond. W/mK.486 Viscosity Pas 1.66E-3 Volume flow m3/h Velocity m/s Tecnical datas Tubes total Piece 264 Tubes: flat Cu+8μSn Tubes blanc Piece staggered Internal ventings Piece Collectors: 1.33 m/s Cu+8μSn Internal drains Piece Connections: 1.33 m/s Rg7 Tube rows on the depth Piece 6 Fins: flat AlMg3 Tube rows on the height Piece 44 Frame: 2. mm AISI 4 Tube coupling in series Piece 2 Circulations: 1 Standard Number of circuits (NC) Piece 132 Protection: without Volume l Weight kg 1331 Connections G --- NW1 Air flow direction: horizontal Frame height RH mm 18 Special: Bottom plate perforated Frame width BT mm 328 for perfect condensate drain Frame depth RT mm 39 Finned height LH mm 176 Finned width LB mm Finned depth LF mm 8 Frame on top RO mm Frame on bottom RU mm Frame in front RV mm Frame on back (~69mm) RN mm 69 Collector-Diameter K mm 168 Collector covering AD mm 9 Collector distance KA mm 189 Fin spacing LT mm 3. Fin thickness LD mm. Delivery: 9- weeks Tube diameter DA mm 16. Validity: 12 weeks Tube thickness S mm. Condit.: net, prepaid adress Tube intervall on the height S1 mm Payment: days net Tube intervall on the depth S2 mm Price net: EUR 1797 ÆK AD RV LB LT BT RN 1 2 KA LF RT 3 4
3 RU G LH RH RO Type /3/16-6R-44T-A-3.PA-132C Capacity kw 6 Surface reserve 1 Present surface m Required surface m Heat transfer coefficient W/m2K ffi:.e- Mean temp. diff. ( 9.7 ) K 7.3 ffa:.e- Air humid Inlet Outlet Definition Height over sea level m 4 Pressure hpa 967 Temp. C Rel. humidity Istanbul, Abs. humidity g/kg Density humid kg/m Enthalpy humid kj/kg Volume flow humid m3/h Mass flow dry kg/h Velocity m/s Pressure drop Pa Et.glycol Inlet Outlet Medium Temp. C Density kg/m Heat cont. kj/kgk Heat cond. W/mK.486 Viscosity Pas 1.66E-3 Volume flow m3/h Velocity m/s Tecnical datas Tubes total Piece 264 Tubes: flat Cu+8μSn Tubes blanc Piece staggered Internal ventings Piece Collectors: 1.33 m/s Cu+8μSn Internal drains Piece Connections: 1.33 m/s Rg7 Tube rows on the depth Piece 6 Fins: flat AlMg3 Tube rows on the height Piece 44 Frame: 2. mm AISI 4 Tube coupling in series Piece 2 Circulations: 1 Standard Number of circuits (NC) Piece 132 Protection: without Volume l Weight kg 1331 Connections G --- NW1 Air flow direction: horizontal Frame height RH mm 18 Special: Bottom plate perforated Frame width BT mm 328 for perfect condensate drain Frame depth RT mm 39 Finned height LH mm 176 Finned width LB mm Finned depth LF mm 8 Frame on top RO mm Frame on bottom RU mm Frame in front RV mm Frame on back (~69mm) RN mm 69 Collector-Diameter K mm 168 Collector covering AD mm 9 Collector distance KA mm 189 Fin spacing LT mm 3. Fin thickness LD mm. Delivery: 9- weeks Tube diameter DA mm 16. Validity: 12 weeks Tube thickness S mm. Condit.: net, prepaid adress Tube intervall on the height S1 mm Payment: days net Tube intervall on the depth S2 mm Price net: EUR 1797 ÆK AD RV LB LT BT RN 1 2 KA LF RT 3 4
4 Economy Fill water requirement: 9.16 less than a open-cooling-tower! Year: 876 Hours Station Water Day Night Temp. Day Night Zürich (199-) kg/h t/a t/a C h h. 39. Capacity kw Et.glycol h Temp. in C Temp. out C Volume flow m3/h Mass flow kg/h Istanbul, Pressure drop kpa Ext. pressure kpa Pressure drop total kpa Pump-Efficiency Pump power kw Energy costs EUR Wet-Service (21.6) h Temp. C Rel. humidity Abs. humidity g/kg Air humid ( /) m3/h Mass flow dry kg/h Pressure drop Pa Box Pa Ext. pressure Pa Pressure drop total Pa Fan-Efficiency Fan power kw Hours Energy costs EUR Humidifier (21.6) h Night Temp. C Day Humidification kg/h Dry Humidification (Max.) kg/h Pressure drop kpa Pump-Efficiency Pump power kw Energy costs EUR Day + Waste water t/a Night + Waste water t/a Total + Waste water t/a Water EUR Dry-Service (78.44) h Temp. C Rel. humidity Abs. humidity g/kg Air humid ( /) m3/h Mass flow dry kg/h Temp. ( C) Pressure drop Pa Box Pa Days Ext. pressure Pa Pressure drop total Pa Fan-Efficiency Fan power kw Energy costs EUR Service - Energy costs -16. Night Daily hours () h/a Day Night hours () h/a Dry Electric energy (MWh) EUR Water (t) EUR Life cycle Years Support costs Capital-interest Inflation Energy-increase Investment-costs EUR Water + Energy costs EUR Support costs EUR Overheads EUR Temp. ( C) Capital costs EUR
5 Economy Capital-interest 4. Energy-increase 2. Inflation 2. Support costs. Investment-costs Open cooling tower EUR 6 Hybrid-Re-Cooler EUR Additional costs EUR 492. Overheads Support costs (+) EUR 24.6 Energy costs: Open cooling tower (-) EUR 1 Energy costs: Hybrid-Re-Cooler (+) EUR Energy costs: EUR Amortization BEP (Break even point) Years.11 Istanbul, Incomes (EUR) - Expenses (EUR) Years Humidifiers - Fresh-water Hybrid-Re-Cooler Pressure 2 to 16 bar ph 6 to 8 Hardness < 3 fh Chloride < mg/l Conduc. < 8 μs/cm Air Fin coil Counteragent to corrosion and anorg. deposits Counteragent to micro organism and algae growth Desalination plant with conductance writer Adiabate Cooling Hybrid Cooling
DEH software (Energy need of air conditioning units)
DEH software (Energy need of air conditioning units) The software DEH calculated not only the entire energy needs of air-conditioning units, but also the operating costs (heating, cooling, electricity,
More informationCRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
More informationTHE PSYCHROMETRIC CHART: Theory and Application. Perry Peralta NC State University
THE PSYCHROMETRIC CHART: Theory and Application Perry Peralta NC State University PSYCHROMETRIC CHART Identify parts of the chart Determine moist air properties Use chart to analyze processes involving
More informationSTEAM TURBINE 1 CONTENT. Chapter Description Page. V. Steam Process in Steam Turbine 6. VI. Exhaust Steam Conditions, Extraction and Admission 7
STEAM TURBINE 1 CONTENT Chapter Description Page I Purpose 2 II Steam Turbine Types 2 2.1. Impulse Turbine 2 2.2. Reaction Turbine 2 III Steam Turbine Operating Range 2 3.1. Curtis 2 3.2. Rateau 2 3.3.
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More information1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.
Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study
More informationElegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationCoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationVicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.
Vicot Solar Air Conditioning V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.cn Cooling, heating, and domestic hot water. Return on investment
More informationChilled Water Precision Air Conditioner For Critical Application
AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.
More informationCoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationChapter 3.4: HVAC & Refrigeration System
Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration
More informationFAN COIL UNIT SOFTWARE User Manual
User Manual Thanks for using Tiba fan coil units' selection software. To start the selection process to software selection there are some steps we need to follow: Front page: 1. Only selection 2. Performance
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationKONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
More informationPerformance Test of Solar Assisted Solid Desiccant Dryer
Performance Test of Solar Assisted Solid Desiccant Dryer S. MISHA 1,2,*, S. MAT 1, M. H. RUSLAN 1, K. SOPIAN 1, E. SALLEH 1, M. A. M. ROSLI 1 1 Solar Energy Research Institute, Universiti Kebangsaan Malaysia,
More informationENGINEERING INFORMATION Hot water and steam service
ENGINEERING INFORMTION Hot water and steam service WHT IS STEM? Like other substances, water can exist in the form of a solid, when we call it ice; as a liquid when we call it water or as a gas when we
More informationHow To Understand Evaporator
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationPRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)
PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold
More informationCURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers
CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building
More informationPLUG and PLAY VRV Connection
PLUG and PLAY VRV Connection All seasons Perfect c mfort Heating Air Conditioning Applied Systems Refrigeration Pricelist 2010 Air Handling Units for > VRV Indoor units and Air Handling Units on single
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationRules for Classification and Construction Ship Technology
I Rules for Classification and Construction Ship Technology 1 Seagoing Ships 19 Guidelines for the Carriage of Refrigerated Containers on Board Ships Edition 2003 The following Guidelines come into force
More informationROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
More information- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
More informationComparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal
Technical Bulletin By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal SUMMARY Refrigeration air coolers (evaporators)
More informationSession 2: Hot Water Supply
MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:
More informationVXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationA MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS
A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS W. M. Torres, P. E. Umbehaun, D. A. Andrade and J. A. B. Souza Centro de Engenharia Nuclear Instituto de Pesquisas Energéticas e Nucleares
More informationFREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES
FREESTUDY HEAT TRANSFER TUTORIAL ADVANCED STUDIES This is the third tutorial in the series on heat transfer and covers some of the advanced theory of convection. The tutorials are designed to bring the
More informationwww.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
More informationITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
More informationAdvances in Gas Cooler Design and the New Gas Cooler Product Selector
Advances in Gas Cooler Design and the New Gas Cooler Product Selector Simon Jones Engineering Manager Sean Armitage Sales Manager Introduction GEA Searle Over 90 years experience in the design and manufacture
More informationInitial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems
Abstract Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems M. Jaradat, R. Heinzen, U. Jordan, K. Vajen Kassel University (Germany), Institute
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationWe have been working in an ideal climate for thirty years.
Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the
More informationPRODUCT DIRECT EVAPORATIVE COOLING PAD DATA SHEET
DIRECT EVAPORATIVE COOLING PAD The only evaporative media with a saturation efficiency over 90% using less than 50% of the volume. Modular Plug & Play design. PRODUCT DATA SHEET DESCRIPTION The OXYVAP Pad
More informationSpecials. www.ika-apparatuur.nl. designed. 3rd edition 2015 English. for scientists 1
Specials www.ika-apparatuur.nl 3rd edition 2015 English designed for scientists 1 IKA Specials Quarterly Campaign III Three is a charm With over 100 years of experience, IKA continues to strive for delivering
More informationRefrigeration Compressed Air Dryer Buran Ultrapulse
Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of
More informationKINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005
KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO SAUDI STANDARD DRAFT No. 3457/2005 NON-DUCTED AIR CONDITIONERS AND HEAT PUMPS TESTING AND RATING PERFORMANCE This standard is developed
More informationIn Row Cooling Options for High Density IT Applications
In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions
More informationCOIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
More informationBy: Jaap Hoogland SPX Cooling Technologies GmbH. CW /Jaap Hoogland/ 16-10-2007 Seawater Cooling Tower Circuits 1
By: Jaap Hoogland SPX Cooling Technologies GmbH CW /Jaap Hoogland/ 16-10-2007 Seawater Cooling Tower Circuits 1 SUMMARY Seawater recooling systems Technique required for seawater cooling towers Heat calculation
More informationData Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
More informationTotal Heat Versus Sensible Heat Evaporator Selection Methods & Application
Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration
More informationSWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
More informationPractice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29
_02 A centrifugal with a 12 in. diameter impeller requires a power input of 60 hp when the flowrate is 3200 gpm against a 60 ft head. The impeller is changed to one with a 10 in. diameter. Determine the
More informationDefining Quality. Building Comfort. Heating and Cooling Coils
Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.
More informationBattery Thermal Management System Design Modeling
Battery Thermal Management System Design Modeling Gi-Heon Kim, Ph.D Ahmad Pesaran, Ph.D (ahmad_pesaran@nrel.gov) National Renewable Energy Laboratory, Golden, Colorado, U.S.A. EVS October -8, 8, 006 Yokohama,
More informationSWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
More informationPioneer in sustainability
Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.
More informationDERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
More informationWater Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling
Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series
More informationEAGLE ASSET TRACKING DATABASE
EAGLE ASSET TRACKING DATABASE Eagle Inspection Technologies offers a user friendly Asset Tracking Database designed specifically for small industrial facilities (Power Plants, Chemical Plants, Tank Farms,
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationHigh-efficient gas boiler CompactGas
High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard
More informationUNIT 2 REFRIGERATION CYCLE
UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression
More informationAbsolute and relative humidity Precise and comfort air-conditioning
Absolute and relative humidity Precise and comfort air-conditioning Trends and best practices in data centers Compiled by: CONTEG Date: 30. 3. 2010 Version: 1.11 EN 2013 CONTEG. All rights reserved. No
More informationsaving energy in comfort Factsheet Recair Enthalpy
saving energy in comfort Factsheet Recair Enthalpy Introduction Enthalpy Exchanger The enthalpy exchanger is able to transfer both sensible heat and latent heat (moisture) from the cooled to the heated
More informationData Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationPresented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE <walterjohnston@bellsouth.net
Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE
More informationOIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.
FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic
More informationEHDC. Cooling system for Data Center and server cabinets.
EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment
More informationAir Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
More informationFluid Mechanics: Static s Kinematics Dynamics Fluid
Fluid Mechanics: Fluid mechanics may be defined as that branch of engineering science that deals with the behavior of fluid under the condition of rest and motion Fluid mechanics may be divided into three
More informationSECTION 3: CLARIFICATION AND UTILITIES (1)
CHPR4402 Chemical Engineering Design Project The University of Western Australia SECTION 3: CLARIFICATION AND UTILITIES (1) Aaliyah Hoosenally 10428141 TEAM A: ALCOHOLICS ANONYMOUS AALIYAH HOOSENALLY,
More informationINDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationHP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
More informationInstallation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
More informationFilter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
More informationExperimental Evaluation Of The Frost Formation
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Experimental Evaluation Of The Frost Formation Yusuke Tashiro Mitsubishi
More informationSolar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
More informationINDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES
More informationHEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi
HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi 2 Rajesh Dudi 1 Scholar and 2 Assistant Professor,Department of Mechanical Engineering, OITM, Hisar (Haryana)
More informationData Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity
Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,
More informationDigital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationWaste Heat Recovery through Air Conditioning System
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn : 2278-800X, www.ijerd.com Volume 5, Issue 3 (December 2012), PP. 87-92 Waste Heat Recovery through Air Conditioning
More information226 ежглеяис тгс йубеямгсеыс (теувос деутеяо) 80 90 : 3 CxHy CO2 H2O. CxHy + (x+y/4) O2 xco2 + y/2 H2O + Q () CO ( ).
226 ежглеяис тгс йубеямгсеыс (теувос деутеяо) I 80 90 1 / / 1 (C) ( 2 ) CO 2 2 21 % 79 % 3 CxHy CO2 H2O CxHy + (x+y/4) O2 xco2 + y/2 H2O + Q () 4 CO2 ( ) 5 CO2 ( ) CO ( ) 6 1atm 100C 7 8 ( ) 9 10 11 12
More informationWeiss Mobile Air Conditioning Systems
Weiss Mobile Air Conditioning Systems SHELTER AIR CONDITIONING System Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik Worldwide... Weiss Umwelttechnik GmbH is one of the world s most important
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationCANNON T4 MINI / MICRO DATA CENTRE SYSTEMS
CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS Air / Water / DX Cooled Cabinet Solutions Mini Data Centre All in One Solution: Where there is a requirement for standalone computing and communications, or highly
More informationSolar Thermal Energy Storage Technologies
Solar Thermal Energy Storage Technologies Doerte Laing, German Aerospace Center (DLR) ENERGY FORUM, 10,000 Solar GIGAWATTS Hannover, 23. April 2008 Folie 1 Energy Storage for Concentrating Solar Power
More informationThermal Design of Cooling and Dehumidifying Coils
14 Thermal Design of Cooling and Dehumidifying Coils M. Khamis Mansour and M. Hassab Mechanical Engineering Department, Faculty of Engineering, Beirut Arab University, Lebanon 1. Introduction The cooling
More informationPump Formulas Imperial and SI Units
Pump Formulas Imperial and Pressure to Head H = head, ft P = pressure, psi H = head, m P = pressure, bar Mass Flow to Volumetric Flow ṁ = mass flow, lbm/h ρ = fluid density, lbm/ft 3 ṁ = mass flow, kg/h
More informationLegacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
More informationUsing waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling
Using waste heat with gas-fired steam humidifiers Condair GS Humidification and evaporative cooling Economical and ecological steam production with gas as primary energy. Gas-operated steam humidification
More information