1 Can you afford to ignore energy costs of IT infrastructure? A practical guide to more efficient data operations. Powering IT
2 Executive Summary Energy costs are expected to double over the next 10 years. In this time, the amount of energy consumed by data centres is also expected to double. This has serious potential to affect an organisation s ability, whether commercial or public sector, to grow its services, expand its reach or develop shareholder value through increased business activity. No surprise that IT energy costs are increasingly prominent in executive thinking. A recent British Chamber of Commerce survey of almost 3,500 businesses shows that: Nearly 40% of businesses feel that rising costs have adversely affected their growth - a clear signal that action is needed. Almost a quarter (22%) have experienced an unexpected increase in charges by their energy supplier over the past three years. Most businesses recognise the need to improve their energy efficiency, with 63% saying environmental concerns motivate them to reduce energy usage. Energy costs now equate to 25% of the total cost of ownership of IT servers and storage solutions. Minimising the energy footprint of IT infrastructure should now be a strategic priority for any business seeking to protect profitability and market competitiveness. Whether running an in-house facility, using a third party managed service or a colocation facility, it is vital that businesses address IT energy usage; understand how they can contribute to efficiency; and seek to minimise what can be one of the largest operational running costs associated with their business. 2 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
3 Energy Use Global data centre markets are expected to grow 50 percent by 2020 to $78 billion, according to Microsoft. Clearly, with the world already in an energy crisis, the high energy costs associated with data centres are no longer just an IT problem. Data centre energy consumption is an issue for everyone because its impact be it surcharges, taxes or lost productivity due to outages will affect all businesses. Data centres have large energy appetites, which will only increase due to our ever-increasing dependence on information technology and communication equipment to significantly improve our productivity and efficiency. The problem with many in-house facilities is that the responsibilities for managing energy resources can be fragmented and conflicting objectives may exist between different departments. Many IT professionals, while highly skilled, may not necessarily be trained in energy resource management. In addition, the requirement to operate high availability systems, capable of supporting global markets while backing up data in periods of lower activity, also challenges many businesses ability to make tangible energy savings. Measuring Efficiency Whilst there are many measures of data centre operational efficiency and environmental best practice management, one of the more referenced benchmarks is the Power Usage Effectiveness (PUE) calculation and data centre infrastructure management, or DCiM. These seek to confirm the conversion of power to a customer rack to the overall electrical consumption required to provide an appropriate hosting facility. According to the Uptime Institute s 2012 Data Centre Survey, the global average of respondents largest data centres is between 1.8 and PUE is a great metric and, when used wisely, it can help organisations easily improve energy efficiency, often by 20% and more. Unfortunately for data centre managers, the efficiency gains attained with a PUE focus are almost all on the facilities side of the equation and, while IT and the data centre may have gained some benefits (e.g. improved cooling), the lion s share of the operational savings are applied to the facilities budget. For many, the greatest effect still remains with the IT infrastructure as any reduction here creates a proportional saving in facilities costs. Understanding Where Energy Goes Some say that the headlong rush to better PUE s has done little to improve data centre efficiency. Having a facility with a great PUE is one thing, but if your data centre is highly underutilised, or if the resources are poorly managed, it has not solved the real problem of trying to get the most out of the resources you already have. The following pie chart reveals the main areas of power consumption within the data centre. Power Breakdown of the Data Centre Electricity UPS IT Equipment Air Movement Ancillary/Lights Cooling 3 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
4 A considerable proportion of this electrical consumption, typically 25-40% is focused on consistently cooling data centre equipment and ensuring an optimal temperature. This is easier in newer facilities, designed to maximise air flows and consistent temperatures from neatly cabled server and often homogenised equipment which is designed to be more efficient. For legacy computing environments and colocation providers, there are more significant challenges to manage disparate rack temperatures and air flows as well as less efficiently designed and operational IT equipment as rack densities continually increase. It is well understood that legacy data centres are much less efficient but a perception exists that new data centres resolves the energy issue. This is partly true in as much that a new data centre is able to take advantage of new technologies and infrastructure design; with the resulting PUE often closer to 1. But not all colocation data centres are the same. Organisations must thoroughly check energy utilisation as part of their selection criteria in order to make sure their environments are not only optimised for performance but providing the most cost effect use of power. The other major area of power consumption is IT equipment itself. The following diagram shows how this breaks down by component. Energy Required by IT Infrastructure Energy used to power Servers 45% Storage 29% Network 26% Network 26% Servers 45% Storage 29% Inside servers, individual processors are much more efficient, but consuming more absolute power. Source: Gartner estimate 2012 One of the biggest challenges for any data centre is running obsolete or old servers and IT platforms. Servers should be replaced regularly, at least every three years, in order to take advantage of new more energy efficient platforms as they become available. Although this may challenge IT capital investment or asset depreciation, it is imperative to take into consideration the operational costs to power equipment. Energy costs have increased so much over the last three years, that energy efficiency is now a prime feature for hardware manufacturers with newer and more powerful hardware now up to 58 percent more efficient than before. This is a more complex issue for third party commercial data centres where they do not control the equipment specification of their colocation customers. However, Pulsant believes that, in this case, they should provide regular audits and consultative guidance to help their customers to migrate up wherever possible. 4 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
5 Boosting Efficiency There are three key areas that ICT professionals can focus on to improve energy efficiency within their data centres server format and use; airflow optimisation; and heating and ventilation management. Top 10 Tips For Minimising Your IT Energy Appetite 1 Maximise server utilisation with virtualisation and consolidation Most physical servers today run at about 10% to 15% utilisation. Since an idle server can consume as much as 30% of the energy it consumes at peak utilisation. Businesses get more for their energy pound by increasing utilisation levels, using thin client provisioning or virtualisation. Virtualisation is a mature technology that works well to save energy and money, increase computing throughput and free up floor space. It also aids load migration and disaster recovery. Any virtualisation strategy should be seen as continuous improvement, with quarterly reviews of utilisation and consolidation options to drive increased efficiencies. 2 Remove obsolete or underutilised servers The energy consumption of a server is not a linear relationship with workload or the productivity output of that server. An idle server may consume more than 40% of the power that a fully utilised server does. If the typical server is running at 5% utilisation and the target utilisation rate is only 50%, then energy consumption could be greatly reduced by improving server utilisation and turning off unused servers. The Uptime Institute, a consultancy in Santa Fe, USA has studied this issue for several years and says that, between 10% and 30% of servers are dead and could be turned off. Just by taking full advantage of power management features and turning off unused servers can cut data centre energy requirements by about 20%. Again, as part of continual improvement, there should be monthly reviews of redundant equipment and associated removal. Immediate consideration should be given to deploying power management features on servers and storage, regardless of age and monitoring energy consumption. Last but not least, the greatest energy efficiencies are driven by optimising power supplies, processors, hard disks and internal fans. Monitoring utilisation and setting continual efficiency targets with staff incentives is an excellent way to drive these initiatives. 3 Purchase more energy-efficient hardware servers In today s data centre, any improvement in server power consumption can pay large dividends. The less power consumed by servers, storage and networking devices, the less heat generated, and the lower the losses for power distribution. This also reduces the cost of heat extraction at the end of the power lifecycle. Lowering and controlling server power consumption also allows you to deploy more servers per rack and still keep within a data centre s overall power budget. One way to measure the potential improvement is to enable power meeting software on selected units. This can be installed, without disruption, from open source sites. Measurements can then be compared against manufacturer efficiency data for newer specification servers to calculate return on investment. 4 Switch to more efficient power supplies With the less-efficient power supplies found in many commodity servers, efficiency peaks at 70% -75% at 100% utilisation but drops to 65% at 20% utilisation. If average server load is are in the 10% to 15% range, it means that inefficient power supplies can waste nearly half of the power before the power even gets to the IT equipment. The problem is compounded by the fact that every watt of energy wasted by the power supply requires another watt of cooling system power just to remove the resulting waste heat from the data centre. This needn t be the case. Power supplies are available today that attain 80% or higher efficiency even at 20% load however, they do cost significantly more often a 15% to 20% premium. Manufacturers are increasingly providing approved options to switch power supplies in existing storage, networking and server technologies with more efficient units. Installing these can yield a return on investment within 12 months. This is based on an average purchase price of 35, offset against energy savings alone. 5 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
6 5 Where possible implement hot aisle/cold aisle layouts Containment of hot/cold aisles and ducting hot air from cabinets helps to prevent cool/exhaust air mixing within server rooms. Generally rows of cabinets face each other so that cool air can reach the equipment air intakes at the set temperature point for the room. A more recent addition to the consideration of above floor containment is below floor air flow control. A range of under floor panels can be fitted within the raised floor plenum to create efficient cold air pathways direct to the raised floor vented tiles. Pulsant has deployed cold aisle containment across its data centre estate and has recognised significant efficiency gains of circa 30%. These savings are derived from reducing cooling equipment flow rates and set points whilst ensuring customer equipment operates at an optimal 22 Celsius. Customers are actively encouraged to replace caged environments with secure pod environments, coupled with our continued extensive thermal imaging analysis of data halls to target hot spots. Each degree of cooling change represents an annual KwH of 100,000 units which is a significant reduction in energy and cost. 6 Install containment enclosures Containment is generally implemented by physical separation of the hot and cold aisles, using blanking panels, PVC curtains or hard panel boards. Containment strategies may differ depending on various factors, including server tolerance, ambient temperature requirements and leakage from data centres. Pulsant continues to work with customers and provides blanking plates for racks free of charge. We also strive to minimise potential disruptions to air flow when racks are moved or vacated as this can create a negative effect on air circulation and row cooling. 7 Invest in variable speed fan drives CRAC (computer room air conditioning) and DFU (down flow unit) fans consume a lot of power and tend to account for 5% to 10% of a data centre s total energy use. Many energy-efficiency measures hot aisle/cold aisle, containment, free cooling depend on Variable Speed Fans (VSDs) being installed on CRAC and CRAH units to fully realise their energy-saving potential. To sufficiently cool equipment and provide more than one backup unit, data centres concurrently operate multiple CRACs around the clock. A reduction of 10% in fan speed reduces that fan s use of electricity by approximately 25%. A 20% speed reduction yields electrical savings of roughly 45%. The Green Grid recently completed an analysis of return on investment and power usage effectiveness at a data centre where payback for VSDs was calculated at 16 months on capital costs alone. Capital investment in cooling technologies may be considerable, requiring extended periods of depreciation. Manufacturers, therefore, often support retrofit modifications including VSDs to existing units to maximise efficiency. Pulsant has commenced a programme to retrofit our CRAC s and DFU s at scheduled maintenance windows with VSDs. 8 Pay attention to airflow Air flow management addresses the need to improve data centre computer cooling efficiency by preventing the recirculation of hot air exhausted from IT equipment and reducing bypass airflow. There are several methods of separating hot and cold airstreams, such as hot/cold aisle containment and in-row cooling units. Overheating of data centre equipment can result in reduced server performance or equipment damage due to hot exhaust air finding its way into an air inlet. Atmospheric stratification can require setting cooling equipment temperatures lower than recommended. Mixing the cooled air and exhausted air uses more power and increases refrigeration costs. Customers have their part to play as well by ensuring servers are exhausting hot air correctly and not directly into cold aisles, cooling equipment or UPS batteries, as this will affect overall data centre efficiency. 6 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
7 9 Make the most of Free-Air Cooling - but be aware of implications Some data centres in cooler climates can minimise PUE simply by using lower ambient air temperatures and moving this through the data centre and exhausting back to the ambient environment, albeit at a higher temperatures. However, using more efficient cooler air as input to the data centre, and then simply exhausting the hot air into our wider free environment will, over time, simply add to overall carbon footprint, even though it will not be registered through existing efficiency metrics. If the objective is to sustainably reduce global warming and average temperature increases, it needs to be coupled with heat recovery solutions to drive emerging cooling technologies, or low impact temperature management solutions. Do not rely solely on PUE as a measure of data centre carbon efficiencies as this is misleading. Sustainability will only be derived by tackling overall power consumption and reducing carbon production and heated air to protect the environment rather than moving the problem on. 10 Consider economisers to help temperature control Air-side and water-side economisers are definitely more efficient than condensing and chilled air based solutions but both may require careful consideration in terms of air quality and humidity fluctuations as well as external ambient temperatures throughout the year. There are many alternatives which are rapidly gaining acceptance in both commercial and domestic applications for reducing electrical consumption in heating and cooling technologies. From Thermal Storage, Direct Liquid Cooling, Heat Recovery and Evaporative solutions as well as Adiabatic technologies which all leverage to differing extents energy recovery from waste heat to drive cooling solutions. 7 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
8 Ensuring Future Continuity While most businesses appreciate that a cohesive energy policy is critical, many are unaware of the real and present challenge this places on their future operations. Energy Production It takes 10 years to build and bring online electrical generation capacity from gas, coal, tidal and nuclear plants. Solar, wind, biomass and geothermal may be faster but are more variable in terms of generation and maintenance also underlying energy policies dictate the proportion and planning consent which will support their future development. Recent media exposure has highlighted that in the UK, we simply have not invested in a timely manner to provision the replacement generation capacity as legacy units are decommissioned. The scope of the Kyoto agreement and carbon reduction commitments may significantly reduce the UK s electrical capacity generation from This means that it may only be 3-5 years before a significant amount of capacity is potentially mothballed. There is only one new gas power station project currently active. This will replace approximately 10% of the capacity being mothballed at a time when our consumption is ever increasing. In economies where electrical capacity demand is not met with supply, the consequence is initially rolling power cuts but the shortfall cannot be quickly met. No-one is denying the decision and commitment required politically is a significant one and given the extended return on investment profiles from such large scale infrastructure projects the private sector and utilities simply cannot support the scale of these projects in isolation. Power stations have an estimated operational lifecycle of 30 to 40 years; data centres have an operational lifecycle of years. In the UK, we have been provided with very high quality power supply and stability for many years and data centre operations have responded accordingly. Implications for Business In the future, the way we tool up and manage our data centres will need to change dramatically: Currently many UK data centre s deploy only standby rated power generation for diesel generators, eco-mode configured UPS s and quarterly/bi-annual darken site testing. The trouble with mechanical and electrical plant is that they are big ticket capital expense items, which are normally depreciated over 7 to 10 years. Changing these profiles is very costly. However, in the future we may have to design for an increased number of scheduled power disruptions - ones which last for hours not minutes, and which occur on a frequent basis. We may even choose to operate on a scheduled basis on standby generation to optimise energy costs. AFCOM s Data Centre Institute has predicted that more than 90 percent of companies data centres will be interrupted at least once because of power constrictions over the next several years. No matter how many precautions IT and engineering teams take, servers might fail from time to time, routers might delay, and switches might malfunction, which calls for more robust data centre designs, high-availability infrastructure and management systems, and fault-tolerant applications. We need to be prepared. 8 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
9 Design Considerations Data storage facilities will have to be designed and operated differently. Generators These will have to become prime rated, be serviced more frequently and will require more frequent re-fuelling and maintenance. UPS Devices Required to protect critical loads through power interruptions, UPSs will be used much more frequently than ever before. Recharging cycles and autonomy will, therefore, become critical considerations. Testing Monitoring will be required more frequently. To ensure continuity of equipment as well as power and cooling capacities to help IT professional make more informed decisions and manage risk. Temperature Management Many facilities now operate far more efficiently but with a lower tolerance in terms of temperature increases during power disruptions i.e. cooling solutions. Invariably, cooling solutions shutdown under UPS critical supply but restart on power failure when generator supply is activated. The challenge is that the startup sequence can take 5 to 10 minutes to regain fully effective cooling, yet the critical load has been continuously operating during this time and the ambient temperature has escalated a 1 degree per minute! Organisations will need to consider the strategy towards changeover cooling more carefully and have updated procedures to manage temperature control and fluctuations. Failover & Integrity When assessing a data centre, it will become increasingly important to understand the failover operational integrity and management of such events to minimise disruption. This will make integration with cooling solutions ever more critical in terms of optimising temperatures through the year and ambient temperatures. Where issues are experienced, how these are dealt with and the technical competence of the onsite team to manage them will become increasingly important considerations. Multiple Sites Separating solutions across multiple sites will become a necessity rather than looking at the Tier rating of each facility. Selection criteria will need to move beyond protecting against a simple unscheduled failover to managing solution availability through an increased number of scheduled workload migrations. Consider these points and begin to plan accordingly as changing solution design and testing, particularly where solution needs to be moved into new sites to meet site redundancy options from a systems and network perspective will require long term planning. Choosing a data centre provider like Pulsant, who operates facilities across multiple geographic regions and can certify the diversity of network communications and operations to deliver a single service level and outcome for your business will be increasingly important. Last Mile Configurations When considering data centre providers and redundant connectivity, how far do you currently investigate the last mile configurations of these suppliers? If there are more frequent power failures and the data centre provider carries on delivering services but the two independent provider exchanges the connectivity passes through are both impacted by the power loss, your solution may still be active but not reachable. You should consider the service chain really carefully when designing highly available solutions. Colocation SLAs For businesses who take the strategic decision to move some or their entire infrastructure to a third party colocation provider, finding the perfect partner can be a complex process. The myriad of players, solution types and SLA scopes can lead to much confusion and make it difficult to compare like for like. 9 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
10 Conclusion Adopting more effective IT energy management systems can deliver longer term and lasting benefits whilst adding agility to the data centre in its ability to respond to changes in business requirements. Small changes such as paying closer attention to server utilisation and architecture can dramatically impact energy use and associated costs. A watt saved in data centre power consumption saves at least a watt in cooling. Utilising other data centre energy saving techniques such as those outlined in this paper can extend this much further. For many businesses, however, this level of commitment, and the capital expenditure required to ensure operational focus on energy control, is just too great to embrace. When resources are tight and in-house IT departments torn between maintaining operational performance and balancing budget equations, then colocation services can provide an ideal solution. It must be stressed that not all vendors are the same and enterprises need to ensure they thoroughly vet their prospective partner before moving their precious infrastructure. To ensure they can offer a sustainable and energy effective solution, Pulsant advises that the following are included in colocation specification criteria: Virtualisation, Cloud and Migration Services To help you better utilise existing devices and to provide additional capacity as and when you may need it - so that your business doesn t have to oversize its kit to ensure rapid growth. Client Server Auditing and Consultancy Make sure support is available to help you assess the operational efficiency of your existing servers and provide a planned replacement pathway that minimises your capital expense without sacrificing your energy efficiency. Environmental Policy Make sure support is available to help you assess the operational efficiency of your existing servers and provide a planned replacement pathway that minimises your capital expense without sacrificing your energy efficiency. Multiple sites and Multiple Energy Suppliers Continuity will become more of an issue for many businesses. A colocation provider with multiple sites can not only help you find a location close to home but also with facilities to provide mirroring and redundancy sites for those with mission critical requirements. As well as reviewing their internal power plant, make sure they can guarantee external supply through multiple routes in the event of major outages. Commitment to Renewable Energy and Green Grid Membership Ask about your data centre s commitment to green energy and find out if they use sustainable sources. Pulsant, for example, has a 100% renewable energy target across all its ten UK data centres. This means every watt of energy it uses in its facilities, is offset with a watt of energy from a renewable source. Also make sure they are a Green Grid member and are, therefore, active in reducing the impact of their data centres on the environment. 10 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
11 About Pulsant: Experts in cloud, data centre and infrastructure services, Pulsant specialises in highly resilient, high quality IP network, colocation, managed application and cloud hosting. Pulsant supports more than 3,000 mid-tier and enterprise customers from its ten UK-based ISO compliant data centres. We provide world class technology and exceptional people creating advanced and innovative solutions that optimise performance and cost effectively manage, store and safeguard data. Pulsant s Triple-A service models ensures the right Access, Ability and Action to deliver 24/7 support from multiple UK-based operation centres. 100% of the energy used within our data centres is from renewable sources. Pulsant is an HP Cloud Agile partner. For more information, please visit or sales@pulsant.com 11 White Paper: Can you afford to ignore energy costs of IT Infrastructure?
VISIT 2010 Fujitsu Forum Europe 0
VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00
More informationDealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges
More informationData Center Power Consumption
Data Center Power Consumption A new look at a growing problem Fact - Data center power density up 10x in the last 10 years 2.1 kw/rack (1992); 14 kw/rack (2007) Racks are not fully populated due to power/cooling
More informationRe Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
More informationThermal Optimisation in the Data Centre
Thermal Optimisation in the Data Centre Best Practices for achieving optimal cooling performance and significant energy savings in your data centre 1. Thermal analysis 2. Cold-Aisle-Containment 3. Seal
More informationBest Practices. for the EU Code of Conduct on Data Centres. Version 1.0.0 First Release Release Public
Best Practices for the EU Code of Conduct on Data Centres Version 1.0.0 First Release Release Public 1 Introduction This document is a companion to the EU Code of Conduct on Data Centres v0.9. This document
More information2010 Best Practices. for the EU Code of Conduct on Data Centres. Version 2.0.0 Release Public Review Public
2010 Best Practices for the EU Code of Conduct on Data Centres Version 2.0.0 Release Public Review Public 1 Document Information 1.1 Version History Version 1 Description Version Updates Date 2.0.0 2010
More informationGUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group
GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY Public Sector ICT Special Working Group SERVER ROOM ENERGY EFFICIENCY This guide is one of a suite of documents that aims to provide guidance on ICT energy efficiency.
More information2014 Best Practices. The EU Code of Conduct on Data Centres
2014 Best Practices The EU Code of Conduct on Data Centres 1 Document Information 1.1 Version History Version 1 Description Version Updates Date 5.0.1 2014 Review draft Comments from 2013 stakeholders
More informationGreen Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
More informationOffice of the Government Chief Information Officer. Green Data Centre Practices
Office of the Government Chief Information Officer Green Data Centre Practices Version : 2.0 April 2013 The Government of the Hong Kong Special Administrative Region The contents of this document remain
More informationManaging Data Centre Heat Issues
Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design
More informationFree Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
More informationReducing Data Center Energy Consumption
Reducing Data Center Energy Consumption By John Judge, Member ASHRAE; Jack Pouchet, Anand Ekbote, and Sachin Dixit Rising data center energy consumption and increasing energy costs have combined to elevate
More informationEducation Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room
More informationEnergy Efficiency and Availability Management in Consolidated Data Centers
Energy Efficiency and Availability Management in Consolidated Data Centers Abstract The Federal Data Center Consolidation Initiative (FDCCI) was driven by the recognition that growth in the number of Federal
More informationEUROPEAN COMMISSION DIRECTORATE-GENERAL JOINT RESEARCH CENTRE Institute for Energy and Transport Renewable Energy Unit. 2013 Best Practices
EUROPEAN COMMISSION DIRECTORATE-GENERAL JOINT RESEARCH CENTRE Institute for Energy and Transport Renewable Energy Unit 201 Best Practices for the EU Code of Conduct on Data Centres Version 4.0.5 1 Document
More informationDataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences
DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences November 2011 Powered by DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no
More informationAnalysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
More informationTHE GREEN DATA CENTER
GREEN IT THE GREEN DATA CENTER WHERE ECOLOGY MEETS ECONOMY We truly live in an information age. Data Centers serve a very important purpose they provide the global community with nearly unlimited access
More informationEnabling an agile Data Centre in a (Fr)agile market
Enabling an agile Data Centre in a (Fr)agile market Phil Dodsworth Director, Data Centre Solutions 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
More informationGreen Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs
Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs Topics The Why? The How? Conclusion The Why? Drivers for Green IT According to Forrester Research, IT accounts
More informationData Center Energy Profiler Questions Checklist
Data Center Energy Profiler Questions Checklist Step 1 Case Name Date Center Company State/Region County Floor Area Data Center Space Floor Area Non Data Center Space Floor Area Data Center Support Space
More informationEnergy Efficiency Best Practice Guide Data Centre and IT Facilities
2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits
More information2014 Best Practices. for the EU Code of Conduct on Data Centres
EUROPEAN COMMISSION DIRECTORATE-GENERAL JRC JOINT RESEARCH CENTRE Institute for Energy and Transport Renewable Energies Unit 2014 Best Practices for the EU Code of Conduct on Data Centres 1 Document Information
More informationGreen Data Centers development Best Practices
Draft Recommendation ITU-T L.DC Green Data Centers development Best Practices Summary This recommendation is a contribution for the reduction of negative climate impact of Data Centers.
More informationHow To Improve Energy Efficiency In A Data Center
Google s Green Data Centers: Network POP Case Study Table of Contents Introduction... 2 Best practices: Measuring. performance, optimizing air flow,. and turning up the thermostat... 2...Best Practice
More informationData center upgrade proposal. (phase one)
Data center upgrade proposal (phase one) Executive Summary Great Lakes began a recent dialogue with a customer regarding current operations and the potential for performance improvement within the The
More informationGuideline for Water and Energy Considerations During Federal Data Center Consolidations
Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
More informationData Centre Outsourcing a Buyer s Guide
Data Centre Outsourcing a Buyer s Guide The inside guide to deciding whether to outsource your data centre facility and operations and how to select an appropriate partner. This Guide will help you Determine
More informationAustralian Government Data Centre Strategy 2010-2025
Australian Government Data Centre Strategy 2010-2025 Better Practice Guide: Data Centre Power June 2013 17/06/2013 4:12 PM 17/06/2013 4:12 PM Contents Contents 2 1. Introduction 3 Scope 3 Policy Framework
More informationDatacenter Efficiency
EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon
More information- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
More informationCase Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
More information// GREEN IT / DATA CENTRE BUILD GREEN
BUILD GREEN BUILDING A COMPLETELY GREEN DATA CENTRE IS A FANTASTIC WAY FOR COMPANIES TO DRAMATICALLY SHRINK THEIR ENERGY COSTS AND IMPROVE THEIR GREEN CREDENTIALS // 28 / NETWORK MIDDLE EAST / AUGUST 2013
More informationChallenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre
Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre S. Luong 1*, K. Liu 2, James Robey 3 1 Technologies for Sustainable Built Environments, University of Reading,
More informationAIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw
More informationICT and the Green Data Centre
ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by
More informationEU Code of Conduct for Data Centre Efficiency
EU Code of Conduct for Data Centre Efficiency A Green Practice Accredited by British Computer Society (BCS) EU Code of Conduct for Data Centre Efficiency Local Organizer Practices in Data Centre Industry
More informationGreening Commercial Data Centres
Greening Commercial Data Centres Fresh air cooling giving a PUE of 1.2 in a colocation environment Greater efficiency and greater resilience Adjustable Overhead Supply allows variation in rack cooling
More informationEnergy Efficiency Opportunities in Federal High Performance Computing Data Centers
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
More informationCase study: End-to-end data centre infrastructure management
Case study: End-to-end data centre infrastructure management Situation: A leading public sector organisation suspected that their air conditioning units were not cooling the data centre efficiently. Consequently,
More informationCURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers
CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building
More informationDataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
More informationThe Use of Fresh Air in the Data Centre
The Use of Fresh Air in the Data Centre White paper of a round table debate by industry experts on this key topic. Hosted by Keysource with participants including the Uptime Institute. Sophistication Through
More informationServer Room Thermal Assessment
PREPARED FOR CUSTOMER Server Room Thermal Assessment Analysis of Server Room COMMERCIAL IN CONFIDENCE MAY 2011 Contents 1 Document Information... 3 2 Executive Summary... 4 2.1 Recommendation Summary...
More informationEuropean Code of Conduct for Data Centre. Presentation of the Awards 2014
European Code of Conduct for Data Centre Presentation of the Awards 2014 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results European
More informationData center lifecycle and energy efficiency
Data center lifecycle and energy efficiency White Paper Lifecycle management, thermal management, and simulation solutions enable data center energy modernization Introduction Data centers are coming under
More informationSpecialty Environment Design Mission Critical Facilities
Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,
More informationState of the Art Energy Efficient Data Centre Air Conditioning
- White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...
More informationChoosing Close-Coupled IT Cooling Solutions
W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of
More informationData Center Lifecycle and Energy Efficiency
Data Center Lifecycle and Energy Efficiency Lifecycle infrastructure management, power management, thermal management, and simulation solutions enable data center modernization. White Paper October 2014
More informationBenefits of. Air Flow Management. Data Center
Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment
More informationSovereign. The made to measure data centre
Sovereign D ATA C O N N E C T The made to measure data centre Prime Location Within touching distance of everything that s important. 2 Your Customer-Centric Data Centre For the vast majority of organisations
More informationCarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense
CarbonDecisions The green data centre Why becoming a green data centre makes good business sense Contents What is a green data centre? Why being a green data centre makes good business sense 5 steps to
More informationRack Hygiene. Data Center White Paper. Executive Summary
Data Center White Paper Rack Hygiene April 14, 2011 Ed Eacueo Data Center Manager Executive Summary This paper describes the concept of Rack Hygiene, which positions the rack as an airflow management device,
More informationMaking Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire. http://rare-idc.herts.ac.
Making Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire http://rare-idc.herts.ac.uk Making Existing Server Rooms More Efficient Reduction and Re-use
More informationDNA IT - Business IT On Demand
DNA IT - Business IT On Demand September 1 2011 DNA IT White Paper: Introduction to Cloud Computing The boom in cloud computing over the past few years has led to a situation that is common to many innovations
More informationGreen Computing: Datacentres
Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material
More informationRethinking Data Center Design
Rethinking Data Center Design Building the room around the rack can ease cooling challenges and save money By John Collins Segment Manager, Data Centers Eaton Corporation Executive summary For decades,
More informationGuide to Cloud Computing INFORMATION
Guide to Cloud Computing INFORMATION INFORMATION PREFACE 3 INTRODUCTION 3 WHAT IS CLOUD COMPUTING? 3 WHY IS CLOUD COMPUTING IMPORTANT TO ORGANISATIONS OF ALL SIZES? 4 BUSINESS BENEFITS 5 COST BENEFITS
More informationServer room guide helps energy managers reduce server consumption
Server room guide helps energy managers reduce server consumption Jan Viegand Viegand Maagøe Nr. Farimagsgade 37 1364 Copenhagen K Denmark jv@viegandmaagoe.dk Keywords servers, guidelines, server rooms,
More informationDATA CENTER ASSESSMENT SERVICES
DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to
More informationabstract about the GREEn GRiD
Guidelines for Energy-Efficient Datacenters february 16, 2007 white paper 1 Abstract In this paper, The Green Grid provides a framework for improving the energy efficiency of both new and existing datacenters.
More informationCombining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
More informationConsulting Engineering Outsourcing
Consulting Engineering Outsourcing Opportunities, challenges and strategies 5.º Fórum Lusófono das Comunicações Maputo, 24 de Abril de 2014 Maksen 2014 Consulting Engineering Outsourcing AGENDA 01. Data
More informationMeasure Server delta- T using AUDIT- BUDDY
Measure Server delta- T using AUDIT- BUDDY The ideal tool to facilitate data driven airflow management Executive Summary : In many of today s data centers, a significant amount of cold air is wasted because
More informationEuropean Code of Conduct for Data Centre. Presentation of the Awards 2013
European Code of Conduct for Data Centre Presentation of the Awards 2013 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results Started
More informationMinimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis
Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. info@dc-oi.com
More informationRaising Inlet Temperatures in the Data Centre
Raising Inlet Temperatures in the Data Centre White paper of a round table debate by industry experts on this key topic. Hosted by Keysource with participants including the Uptime Institute. Sophistication
More informationDatacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group www.6dg.co.uk
Dedicated managed environment for mission critical services www.6dg.co.uk Our datacentres are the core of our business. At we own and manage 30,000 square feet of highly available, geographically diverse
More informationData Center Trend: Distributed Power in the White Space
Data Center Trend: Distributed Power in the White Space By Jason Anderson Product Line Manager Eaton Executive summary Cloud computing vendors and colocation data centers make every effort to maximize
More informationBRUNS-PAK Presents MARK S. EVANKO, Principal
BRUNS-PAK Presents MARK S. EVANKO, Principal Data Centers of the Future and the Impact of High Density Computing on Facility Infrastructures - Trends, Air-Flow, Green/LEED, Cost, and Schedule Considerations
More information80% of. 50% of. 30% of. 67% of enterprises. Environmental and business demands are converging
Delivering the Green Datacenter Jerome Riboulon, HP 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice 2 24 Abril, 2008 Environmental and
More informationEnergy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling
Energy Efficient Server Room and Data Centre Cooling Computer Room Evaporative Cooler EcoCooling EcoCooling CREC Computer Room Evaporative Cooler Reduce your cooling costs by over 90% Did you know? An
More informationEnergy Management Services
February, 2012 Energy Management Services Data centers & IT environments are often critical to today s businesses, directly affecting operations and profitability. General & Mechanical Services has the
More informationHow To Run A Data Center Efficiently
A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly
More informationData Centre Cooling Air Performance Metrics
Data Centre Cooling Air Performance Metrics Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. info@dc-oi.com Abstract Data centre energy consumption
More informationCooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Kenneth G. Brill, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc. 505.798.0200
More informationDATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
More informationIMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT
DATA CENTER RESOURCES WHITE PAPER IMPROVING DATA CENTER EFFICIENCY AND CAPACITY WITH AISLE CONTAINMENT BY: STEVE HAMBRUCH EXECUTIVE SUMMARY Data centers have experienced explosive growth in the last decade.
More informationAn Introduction to Cold Aisle Containment Systems in the Data Centre
An Introduction to Cold Aisle Containment Systems in the Data Centre White Paper October 2010 By Zac Potts MEng Mechanical Engineer Sudlows October 2010 An Introduction to Cold Aisle Containment Systems
More informationGreen Computing: Datacentres
Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material
More informationManaging Power Usage with Energy Efficiency Metrics: The Available Me...
1 of 5 9/1/2011 1:19 PM AUG 2011 Managing Power Usage with Energy Efficiency Metrics: The Available Metrics and How to Use Them Rate this item (1 Vote) font size Data centers consume an enormous amount
More informationUtilizing Temperature Monitoring to Increase Datacenter Cooling Efficiency
WHITE PAPER Utilizing Temperature Monitoring to Increase Datacenter Cooling Efficiency 20A Dunklee Road Bow, NH 03304 USA 2007. All rights reserved. Sensatronics is a registered trademark of. 1 Abstract
More informationData Center Technology: Physical Infrastructure
Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider
More informationWhich Data Center? Key factors in choosing who to trust with your IT Infrastructure
Which Data Center? Key factors in choosing who to trust with your IT Infrastructure Tarif Abboushi Vice-President of Data Center Infrastructure NTT America May, 2009 Which Data Center? Key factors in choosing
More informationMetering and Managing University of Sheffield Data Centres. Chris Cartledge Independent Consultant C.Cartledge@sheffield.ac.uk
Metering and Managing University of Sheffield Data Centres Chris Cartledge Independent Consultant C.Cartledge@sheffield.ac.uk Summary ICT Electricity Use Footprint Data Centre Electricity Use European
More informationEssential NCPI Management Requirements for Next Generation Data Centers
Essential NCPI Requirements for Next Generation Data Centers By Ted Ives White Paper #14 1 Executive Summary The management of physical infrastructure in data centers can no longer be considered independently
More informationGUIDELINE. on SERVER CONSOLIDATION and VIRTUALISATION. National Computer Board, 7th Floor Stratton Court, La Poudriere Street, Port Louis
GUIDELINE on SERVER CONSOLIDATION and VIRTUALISATION National Computer Board, 7th Floor Stratton Court, La Poudriere Street, Port Louis Introduction There is an ever increasing need for both organisations
More informationFNT EXPERT PAPER. // Data Center Efficiency AUTHOR. Using CFD to Optimize Cooling in Design and Operation. www.fntsoftware.com
FNT EXPERT PAPER AUTHOR Oliver Lindner Head of Business Line DCIM FNT GmbH // Data Center Efficiency Using CFD to Optimize Cooling in Design and Operation Energy is the biggest cost factor with the highest
More informationYour guide to hosted data centres: How to evaluate potential providers
Your guide to hosted data centres: How to evaluate potential providers Finding the right hosted data centre More than ever, organizations require a secure, reliable and flexible data centre to meet growing
More informationI-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014
I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 4, Lancaster University, 2 nd July 2014 Background Data centres estimated to use 2-3% of total electricity consumption in the UK and generate
More informationColocation Selection Guide. Workspace Technology Ltd
Colocation Selection Guide Workspace Technology Ltd Technology House 5 Emmanuel Court Reddicroft Sutton Coldfield West Midlands B72 1TJ Tel 0121 354 4894 Fax 0121 354 6447 www.workspace-technology.com
More informationConvergence of Complexity
Convergence of Complexity Optimize Existing Data Center Space Measure And Allocate Energy Cost Plan for new data centers or additional capacity How to make your Data Center Last Longer, Gartner, December
More informationEuropean Business Reliance Centres when Commodity serves Green IT
European Business Reliance Centres when Commodity serves Green IT www.ebrc.com www.trusteddatacentre.com www.trustedcloudeurope.com www.trustedmanagedservices.com ebrc COMPANY PROFILE 5 datacenters = 17.000
More informationInfrastructure & Software
Managed Services We can provide you with a fully managed service more than simply hosting or co-location but a full end-to-end and single point of contact service. Infrastructure & Software Datacentres
More informationHow High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions
Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel
More informationNational Grid Your Partner in Energy Solutions
National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National
More information