NOCT: Normal Operation Cell Temperature

Size: px
Start display at page:

Download "NOCT: Normal Operation Cell Temperature"

Transcription

1 Let the sunshine in. Compendium for SOLARWATTsystems and components Valid from 1/9/214

2 New New and interesting for your business: Package offers with price advantages for various modules: Module + Inverter SOLARWATT Carport and Veranda as systems or package offers for self-sufficient solar energy supply Optimized SOLARWATT facade system with dual function: facade element and self-sufficient energy supply with unique 1 year warranty and new Steca 3-phase inverter device series. Worldwide warranty for all SOLARWATT BLUE modules and improved worldwide performance warranty for glass-glass modules Page 2 Back to the table of contents SOLARWATT BLUE 6M - high output up to 27 Wp SOLARWATT 36P - highly resilient and compact - for optimal roof design

3 Contents Page Page Carport system 4 Veranda system 8 Easy-In system 12 Facade system 17 SOLARWATT StecaGrid 33 SOLARWATT Scout design software 35 Steca 36 SMA 37 Glass-glass modules 21 SOLARWATT 6M style 21 SOLARWATT 6P 23 SOLARWATT 36P 25 SOLARWATT services and qualifications SOLARWATT services 39 SOLARWATT qualifications 43 Page 3 Back to the table of contents SOLARWATT 36 glass/xl glass 27 Glass-foil modules 29 SOLARWATT BLUE 6M 3 SOLARWATT BLUE 6P 31

4 Carport system The design system for independence and electromobility Designer glass-glass modules "Made in Germany" 19 % transparency Durable and innovative glass-glass combination Monocrystalline solar cells High-yield, highly resistant and highly resilient General building authority approval Made of high-quality wood Made using traditional carpentry methods Robust, mortised beams Highly stable Choice of finish (white, brown, black, colorless) Page 4 Back to the table of contents SOLARWATT Full Coverage Insurance covering all own damage Compensates for lost earnings Makes up the shortfall if yields fall below minimum Services/qualifications

5 Carport system Carport system* Depth x width Installed power [kwp] Number of modules itions Positions Clearance Carport system* Depth x width Installed power [kwp] Number of modules Pos- Clearance V1 6, x 3, V6 9, x 4,5 V1 6, x 3, V6 9, x 4,5 V1 6, x 3, V1 6, x 3, V1 6, x 3, V1 6, x 3, V2 7,5 x 3, Carport V1 6. x 3. m V6 9, x 4,5 V6 9, x 4,5 V6 9, x 4,5 V6 9, x 4,5 V7 6, x 6, V1 6, x 3, V6 9, x 4,5 V1 6, x 3, V6 9, x 4,5 V2 7,5 x 3, V7 6, x 6, Carport V6 9. x4.5 m V2 7,5 x 3, V2 7,5 x 3, V2 7,5 x 3, V2 7,5 x 3, V3 9, x 3, V3 9, x 3, V3 9, x 3, V3 9, x 3, V3 9, x 3, V4 6, x 4,5 V4 6, x 4,5 V4 6, x 4,5 V4 6, x 4,5 V4 6, x 4,5 Carport V2 7.5 x 3. m Carport V3 9. x 3. m V7 6, x 6, V7 6, x 6, V7 6, x 6, V7 6, x 6, V8 7,5 x 6, V8 7,5 x 6, V8 7,5 x 6, V8 7,5 x 6, V8 7,5 x 6, V9 9, x 6, V9 9, x 6, V9 9, x 6, V9 9, x 6, V9 9, x 6, 3.1 V1 6, x 3, 2 V2 7,5 x 3, V3 9, x 3, V4 6, x 4, V6 9, x 4,5 V7 6, x 6, V2 7,5 x 3, V7 6, x 6, V3 9, x 3, V8 7,5 x 6, V2 7,5 x 3, V7 6, x 6, V8 7,5 x 6, V3 V4 9, 6, x 3, x 4,5 V8 V9 7,5 9, x 6, x 6, V3 9, x 3, V8 7,5 x 6, V4 6, x 4,5 V9 9, x 6, V9 9, x 6, Carport V7 6. x 6. m Carport V8 7.5 x 6. m Page 5 Back to the table of contents V5 7,5 x 4,5 V5 7,5 x 4,5 V5 7,5 x 4,5 Carport V4 6. x 4.5 m V5 7,5 x 4,5 V4 6, x 4,5 V5 7,5 x 4,5 V9 9, x 6, V5 7,5 x 4,5 V5 7,5 x 4,5 Carport V5 7.5 x 4.5 m V5 7,5 x 4, V5 7,5 x 4,5 Carport V9 9. x 6. m Customized carport solutions On request * Listed in the price list are valid for the natural spruce model. SOLARWATT recommends applying a finishing coat to this model to ensure a long service life. You will find suitable factory-provided finishing coats in the price list for system accessories. Sale and installation only by trained and certified SOLARWATT partners See page 37 for the system scope of supply. Services/qualifications

6 Carport system accessories Additional components SOLARWATT CARPORT SYSTEM Side wall/unit Rear wall/unit Carport V2, 3, 5, 6, 8, 9 Equipment room 1.5 m depth (per unit) Carport V3, 6, 9 Equipment room 3. m depth (per unit) Round arch / unit Version in natural spruce Surcharge for 3-layer coating, in white, brown, black or colorless varnish Surcharge for 3-layer coating in a non-standard RAL color Surcharge for natural Douglas fir finish Page 6 Back to the table of contents Base plate for installation of a charging station/wallbox Customized carport solutions Supervisor (tool, 2 skilled workers) Services/qualifications

7 Carport system scope of supply outside purlins cable channel In the carport system in addition to the solar modules contained components: inside purlins rafters rafter heads angle braces posts H post anchor Mounting system EPDM rubber for rafter installation Clamping profile Corrugated seal Glass joint seal strip Ridge piece and fascia board Gable board Gutter system including gutter brackets and downpipe Other items Full border enclosure All required fasteners and seals Page 7 Back to the table of contents Attention: Concrete for foundation is not included in the scope of supply. Approximately 3-4 bags must be factored in for each point foundation. Services/qualifications

8 Veranda system The veranda system as a sun shade and energy source Designer glass-glass modules "Made in Germany" 19 % transparency Durable and innovative glass-glass combination Monocrystalline solar cells High-yield, highly resistant and highly resilient General building authority approval SOLARWATT Full Coverage Insurance covering all own damage Compensates for lost earnings Makes up the shortfall if yields fall below minimum Page 8 Back to the table of contents Made of high-quality wood Made using traditional carpentry methods Robust, mortised beams Highly stable Choice of finish (white, brown, black, colorless) Services/qualifications

9 Veranda system Veranda system* Depth x width Installed power [kwp] Number of modules Veranda system* Depth x width Installed power [kwp] Number of modules V1 3, x 4,5 V6 6, x 6, V1 3, x 4,5 V6 6, x 6, V1 3, x 4,5 V1 3, x 4,5 V2 4,5 x 4,5 Veranda V1 3. x 4.5 m V6 6, x 6, V6 6, x 6, V7 3, x 9, 1.86 V1 3, x 4,5 12 V1 3, x 4,5 V2 4,5 x 4,5 V6 6, x 6, V6 6, x 6, V7 3, x 9, Veranda V6 6. x6. m V2 4,5 x 4,5 V2 4,5 x 4,5 V3 6, x 4,5 V3 6, x 4,5 V3 6, x 4,5 V4 3, x 6, V4 3, x 6, V4 3, x 6, V5 4,5 x 6, V5 4,5 x 6, Veranda V2 4.5 x 4.5 m Veranda V3 6. x 4.5 m Veranda V4 3. x 6. m V7 3, x 9, V7 3, x 9, V8 4,5 x 9, V8 4,5 x 9, V8 4,5 x 9, V9 6, x 9, V9 6, x 9, V9 6, x 9, V1 3, x 4,5 V2 4,5 x 4, V2 4,5 x 4,5 V3 6, x 4,5 V2 4,5 x 4,5 V3 6, x 4,5 V3 6, x 4, V4 3, x 6, V3 6, x 4,5 V4 3, x 6, V4 3, x 6, V4 3, x 6, V5 4,5 x 6, V5 4,5 x 6, V6 6, x 6, V7 3, x 9, V7 3, x 9, V8 4,5 x 9, V7 3, x 9, V8 4,5 x 9, V8 4,5 x 9, V9 6, x 9, V8 4,5 x 9, V9 6, x 9, V9 6, x 9, V9 6, x 9, Veranda V7 3. x 9. m Veranda V8 4.5 x 9. m Page 9 Back to the table of contents V5 4,5 x 6, Veranda V5 4.5 x 6. m V5 4,5 x 6, V5 4,5 x 6, Veranda V9 6. x 9. m Customized veranda solutions On request * Listed in the price list are valid valid for the natural spruce model. SOLARWATT recommends applying a finishing coat to this model to ensure a long service life. You will find suitable factory-provided finishing coats in the price list for system accessories. Sale and installation only by trained and certified SOLARWATT partners See page 42 for the system scope of supply. Services/qualifications

10 Veranda system accessories Additional components SOLARWATT VERANDA SYSTEM Side wall/unit Version in natural spruce Surcharge for 3-layer coating, in white, brown, black or colorless varnish Surcharge for 3-layer coating in a different RAL color Surcharge for natural Douglas fir finish Page 1 Back to the table of contents Wall post/veranda system Supervisor (tool, 2 skilled workers) Services/qualifications

11 Veranda system scope of supply wall purlin outside rafters inside rafters cable channels rafter heads angle braces eave purlin posts H post anchor Included with the veranda system in addition to the components included with the modules: Mounting system EPDM rubber for rafter installation Clamping profile Corrugated seal Glass joint seal strip Ridge piece and fascia board Gable board Gutter system including gutter brackets and downpipe Other items Full border enclosure All required fasteners and seals Page 11 Back to the table of contents Attention: Concrete for foundation is not included in the scope of supply. Approximately 3-4 bags must be factored in for each point foundation. Services/qualifications

12 Easy-In System Solar modules in place of roofing tiles Premium solar modules "Made in Germany" Weatherproof roofing which replaces roof tiles Rear ventilation for high yields Resistant and resilient SOLARWATT Full Coverage Insurance covering all own damage Compensates for lost earnings Makes up the shortfall if yields fall below minimum Simple assembly No additional installation system required Fastened directly to the roof battens Limited number of separate parts Page 12 Back to the table of contents Services/qualifications

13 Easy-In System SOLARWATT ORANGE 6M Easy-In style SOLARWATT Service Module dimensions: x 1.35 x 47 mm Roof cover dimensions: x 1.16 x 47 mm Black anodized frame Monocrystalline solar cells 255 Wp 26 Wp (1 % added sorting) SOLARWATT Full Coverage included (up to 1, kwp) Straightforward returns policy as per the Terms of Delivery for Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " Guarantee of origin Quality from Germany Max 54 Pa* *Test conditions, see reverse of data sheet Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl resistant against ammonia resistant against hail resistant against salt mist Page 13 Back to the table of contents Item number Module type Power class (Wp) Modules per pallet Availability if different from standard 9334 SOLARWATT ORANGE 6M Easy-In style SOLARWATT ORANGE 6M Easy-In style Services/qualifications

14 Technical Data SOLARWATT Easy-In System Dimensions General Data Module technology Glass-Foil-Laminate; Aluminium frame, black onodized L x B x D Connection technology Weight The roof constructions must comply with the general requirements of the directives of the Central Association of the German Roofing Trade (ZVDH); the system is designed for 4 x 6 mm roof battens. Short circuit current I SC Solarunterstütze Energiesysteme Module dimensions: x 1.35 x 47 mm; Cover dimensions: x 1.16 x 47 mm Cabels 2 x 1, m / 4 mm², MC4 Connector appr. 24 kg Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN Nominal power P N Nominal voltage U mpp Nominal current I mpp Open circuit voltage U OC Short circuit current I SC IR * Measurement tolerance in reference to Pmax ±5 %; 25 Wp 31, V 8,7 A 38,3 V 8,51 A 255 Wp 31,2 V 8,18 A 38,5 V 8,56 A 2 A 26 Wp 31,4 V 8,29 A 38,7 V 8,61 A Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation Nominal power P N Nominal voltage U mpp Nominal circuit voltage U OC ± ± ± 2 47 SOLARWATT ORANGE 6M Easy-In style SOLARWATT ORANGE 6M Easy-In style 183 W 186 W 19 W 28,4 V 28,6 V 28,7 V 35,7 V 35,9 V 36, V 6,88 A SOLARWATT 6,92 A Bauliche Systeme 6,96 SOLARWATT A Solarmodule SOLARWATT Energetische Bauliche Systeme SOLARWATT Bauliche Systeme ± 2 Covering material Encapsulation Backing material Solar cells Cell dimensions Bypass diodes 3 Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 26 Wp Orange 6M Easy-In style Highly transparent solar glass (tempered), 4 mm EVA solar cells EVA Multi-layer composite film, black 6 monocrystalline solar cells 156 x 156 mm Application class Application class A (acc. to IEC 6173) Max. system voltage Mechanical Ratings as per IEC Ed. Qualifications Hail Resistance 1 V Approved for loads up to 5,4 Pa, Approved for suction loads up to 2,4 Pa (uplift resistance in accordance with DIN 14437) (Wind speed 13 km/h with safety factor 3) Please refer to the specifications in the installation instructions. IEC Ed.2 IEC 6173 (including Protection Class II) Tested with simulated hailstones (Ø 25 mm, at ~83km/h) Fire Resistance Test DIN ENV 1187 Upright as roof integration in pitched roofs on buildings up to 25 m high; roof pitch; 16 minimum roof pitch with Application site usage of a water-tight sub-roof according to the guidelines of the ZVDH (Central Association of German Roofers) Solar modules with special frame, seals, suction protection System Components measures, special screws, sarking membrane, aluminum guide rail Is [A] W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m 2 Thermal Features Us [V] Operating temperature range Ambient temperature range Temperature coefficient P N Temperature coefficient U OC Temperature coefficient I SC NOCT C 5 C 25 C C Us [V] Is [A] SOLARWATT Orange 6M Easy-In style C C -,41 %/K -,33 %/K,5 %/K 45 C Page 14 Back to the table of contents

15 Easy-In System scope of delivery We can supply additional system components on request, at an extra charge. Abb. a) Wind suction retainers Abb. a) Abb. b) Abb. c) Abb. b) Self-drilling wood screws Abb. c) Self-drilling sheet metal screws Abb. d) Transverse seal Abb. e) Transverse seal clip Abb. d) Abb. e) Abb. f) Additional components SOLARWATT EASY-IN SYSTEM Components according to overview (between modules) Abb. f) Right lateral flushing Sarking membrane (75 m 2 roll) Abb. g) Left lateral flushing Abb. h) Top flushing, central area Abb. i) Top flushing, the edge area Abb. j) Spacer gauge (for thermal expansion) Abb. k) Aluminium guide rail Abb. l) Attachmentplate for aluminium guide rail Abb. m) Sarking membrane Abb. n) Guide rail connector set Abb. g) Abb.j) Abb. m) Abb. h) Abb. k) Abb. i) Abb. l) Abb. n) Page 15 Back to the table of contents Services/qualifications

16 Easy-In System underlay sarking membrane Characteristics Unit Value Min Max Components - DIFFLEX Thermo ND Application Functional layer Carrier material Underlay / sarking membrane Special multiple coating Polyester non-woven material Mass per unit area g/m 2 approx Dimensional accuracy % 1 Thickness mm,8,6,9 Fire behavior Class E VKF Switzerland fire-resistance rating Rating 5.3 Resistance to water penetration Class W 1 After aging (9 C) Class W 1 Max. tensile force, lengthwise N/5 mm approx Max. tensile force, across N/5 mm approx Max. tensile force after aging (9 C) % > 9% of new value Strain, lengthwise % Strain, across % Strain after aging (9 C) % > 75 % of new value Tear growth resistance/ nail shank, lengthwise N/2 mm approx Tear growth resistance/ nail shank, across N/2 mm approx Diffusion-equivalent air-layer thickness s d -Wert-m approx.,9,5,12 Resistance to air passage m 3 /(m 3 /h/5 Pa),1 Temperature resistance C Cold bending behavior C -4 UV resistance Resistance to driving rain Suitability as temporary roofing material German Roofers Association Class Long-lasting Passed (surface/perforations) 3 months UDB - A / USB-A Meets Austrian Standard B Table 5/ Para UD do - k/ UD do - s Sheeting width m 1,5 -,5% +1,5% Roll length m 5 Roll weight kg approx Packing unit 24 rolls per pallet Highly permeable underlay sarking membrane, consisting of non-woven PES material with a number of special layers and sealing properties. Thanks to excellent heat resistance and the coating, also suitable as a permeable underlay for slate roofing and to build a rainproof sub-roof (Class 2 s ). Can be laid directly on timber cladding or heat insulation. Page 16 Back to the table of contents Services/qualifications

17 Facade system new The power generating system for facade design. Designer glass-glass modules "Made in Germany" Durable and innovative glass-glass combination High-yield, highly resistant and highly resilient General building authority approval SOLARWATT Full Coverage Insurance covering all own damage Compensates for lost earnings Makes up the shortfall if yields fall below minimum Patented facade fastening construction Patented click system of the glass retaining structure Tested according to statics and structural engineering principles Type statics included Page 17 Back to the table of contents All-around worry-free installation Toolless quick-installation system Simple planning and design thanks to type statics of the facade construction Services/qualifications

18 Facade system new The innovative glass-glass generation SOLARWATT Service Brilliant transparent or opaque appearance Exceptionally reliable yield rates Improved mechanical strength 1 % protection against PID Increased fire protection SOLARWATT Full Coverage included (up to 1, kwp) Straightforward returns policy as per the Terms of Delivery for Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " SOLARWATT 36M facade / facade style Guarantee of origin Quality from Germany Monocrystalline solar cells 145 Wp 155 Wp (1 % added sorting) Max 6 Pa* AbZ Z General building authority approval *Test conditions, see reverse of data sheet Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl resistant against ammonia resistant against hail resistant against salt mist Page 18 Back to the table of contents Services/qualifications

19 Technical Data Glass-Glass-Module: SOLARWATT 36M facade / facade style Dimensions General Data Module technology Glass-glass-laminate 23, mm 61, mm 22, mm 35,5 mm 159, mm 22, mm 159, mm Covering material Encapsulation Backing material Solar cells High-transparency floating glass, 4 mm EVA-solar cells-eva floating glass, 4mm, transparent or opaque 36 monocrystalline solar cells Cell dimensions 156 x 156 mm 71 mm mm + - Bypass diodes 2 Application class Application class A (acc. to IEC 6173) Max. system voltage Mechanical Ratings as per IEC Ed. 1 V Suction load up to 2,4 Pa Applied load up to 6, Pa 152 mm 152 mm Anschlusstechnik Cable 2 x,4 m/4 mm², MC4-Connector SOLARWATT 36M facade SOLARWATT 36M facade style Transparency 19 % opak RAL 95 L x B x D Weight 152 ± 2 x 71 ± 2 x 9 ± 1 mm appr. 25 kg Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN SOLARWATT 36M facade / facade style Nominal power P N 145 Wp 15 Wp 155 Wp Nominal voltage U mpp 18,7 V 19, V 19,2 V Nominal current I mpp 7,76 A 7,9 A 8,8 A Open circuit voltage U OC 22,6 V 22,9 V 23,1 V Short circuit current I SC 8,15 A 8,31 A 8,5 A IR * 2 A Measurement tolerance in reference to Pmax ±5 %; Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation SOLARWATT 36M facade / facade style Nominal power P N 16 W 11 W 114 W Nominal voltage U mpp 17,2 V 17,5 V 17,7 V Nominal circuit voltage U OC 21,1 V 21,4 V 21,6 V Short circuit current I SC 6,58 A 6,71 A SOLARWATT 6,87 A Solarmodule Solarunterstütze Energiesysteme SOLARWATT Energetische Bauliche Systeme SOLARWATT Bauliche Systeme Qualifications Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 155 Wp SOLARWATT 36M facade Is [A] Thermal Features 1 W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m Us [V] IEC Ed.2 IEC 6173 (including Protection Class II) SOLARWATT 36M facade / facade style Operating temperature range C Ambient temperature range C Temperature coefficient P N -,4 %/K Temperature coefficient U OC -,32 %/K Temperature coefficient I SC,5 %/K NOCT 45 C Is [A] Is [A] 7 C5 C 25 C C Us [V] 3 4 Page 19 Back to the table of contents

20 Facade system scope of supply Loose bearing console Supporting profile Connecting element Supporting profile Fixed console bearing 4-point bracket; wind load.9 kn, suction load up to.9 kn/m 2 Page 2 Back to the table of contents Module holder Attention: The required fastening elements of the system to the foundation are material-dependent and are not included in the scope of supply! 6-point bracket; wind load 1.5 kn, suction load up to 1.5 kn/m 2 Services/qualifications

21 Glass-glass module: SOLARWATT 6M style The innovative glass-glass generation SOLARWATT Service Ultra-light weight thanks to glass just 2 mm thick Exceptionally reliable yield rates Improved mechanical strength 1 % protection against PID Increased fire protection Straightforward returns policy as per the Terms of Delivery for Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " SOLARWATT 6M style Guarantee of origin Quality from Germany Monocrystalline solar cells 265 Wp 275 Wp (1 % added sorting) Max 9 Pa* *Test conditions, see reverse of data sheet Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl resistant against ammonia resistant against hail resistant against salt mist Page 21 Back to the table of contents Item number Module type Power class (Wp) Modules per pallet Availability if different from standard 948 SOLARWATT 6M style SOLARWATT 6M style SOLARWATT 6M style 27 3 On request Services/qualifications

22 Technical Data Glass-Glass-Module: SOLARWATT 6M style Dimensions General Data 3 4,2 W N ±2 86 Typenschild inkl Seriennummer Module technology Covering material Encapsulation Backing material Solar cells Glass- glass laminate, black anodized aluminum frame High- transparency solar glass, 2 mm EVA-solar cells-eva Prismatic solar glass,2mm 6 monocrystalline solar cells 3 Cell dimensions 156 x 156 mm 2 2 Bypass diodes ±2 Application class Application class A (acc. to IEC 6173) Max. system voltage 1 V L x B x D Connection technology Weight Detail view - mounting bore hole 168 x 99 x 4 mm (+/-2 mm) Cables 1 x,25 m, 1x,45 m/4 mm², MC4-connector appr. 24 kg Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN SOLARWATT 6M style Nominal power P N Nominal voltage U mpp Nominal current I mpp Open circuit voltage U OC Short circuit current I SC 26 Wp 31,7 V 8,21 A 38,8 V 8,8 A 265 Wp 31,9 V 8,31 A 39,1 V 8,9 A 27 Wp 32,2 V 8,39 A 39,3 V 9,2 A 275 Wp 32,4 V 8,94 A 39,5 V 9,11 A IR * 2 A Measurement tolerance in reference to Pmax ±5 %; Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation Nominal power P N Nominal voltage U mpp Nominal circuit voltage U OC Short circuit current I SC 3 Detail view - grounding bore hole ±,3 - SOLARWATT 6M style W 195 W 199 W 222 W 29,3 V 29,4 V 29,7 V 29,9 V 36,4 V 36,6 V 36,8 V 37, V 7,11 A 7,19 A 7,28 A 7,36 A Mechanical Ratings as per IEC Ed. Approved stress load as per SOLARWATT Installation Instructions Qualifications Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 275 Wp SOLARWATT 6M style Is [A] W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m Thermal Features Us [V] Operating temperature range Ambient temperature range Temperature coefficient P N Temperature coefficient U OC Temperature coefficient I SC NOCT Suction load up to 2,4 Pa Applied load up to 5,4 Pa Applied load up to 5.5 Pa (when installed crosswise 1) ) Test condition: sliding load of 9, Pa (conditions take into account safety factors for snow overhang and ice load per Eurocode 1.) 1) Please refer to the specifications in the installation instructions. IEC Ed.2 IEC 6173 (including Protection Class II) 3 4 Is [A] Us [V] SOLARWATT 6 M style C C -,4 %/K -,32 %/K,5 %/K 45 C 7 C 5 C25 C C 3 4 Page 22 Back to the table of contents

23 Glass-glass module: SOLARWATT 6P The innovative glass-glass generation SOLARWATT Service Ultra-light weight thanks to glass just 2 mm thick Exceptionally reliable yield rates Improved mechanical strength 1 % protection against PID Increased fire protection SOLARWATT Full Coverage included (up to 1, kwp) Straightforward returns policy as per the Terms of Delivery for Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " SOLARWATT 6P Guarantee of origin Quality from Germany Item number Polycrystalline solar cells 25 Wp 26 Wp (1 % added sorting) Max 54 Pa* *Test conditions, see reverse of data sheet Module type Max 9 Pa* with additional Crossrail equipment Power class (Wp) Modules per pallet Availability if different from standard Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl resistant against ammonia resistant against hail resistant against salt mist Page 23 Back to the table of contents 9491 SOLARWATT 6P SOLARWATT 6P SOLARWATT 6P 26 3 On request 9475 SOLARWATT 6P with additional Crossrail equipment SOLARWATT 6P with additional Crossrail equipment SOLARWATT 6P with additional Crossrail equipment 26 3 On request Services/qualifications

24 Technical Data Glass-Glass-Module: SOLARWATT 6P Dimensions General Data 168 ±2 Module technology Glass- glass laminate, aluminum frame 3 4,2 W N 84 Covering material Encapsulation Backing material Solar cells High-transparency solar glass, 2 mm EVA-solar cells-eva, white Solar glass, 2 mm 6 polycristalline solar cells Cell dimensions 156 x 156 mm - Bypass diodes ±2 Application class Application class A (acc. to IEC 6173) Max. system voltage 1 V 3 Mechanical Ratings as per IEC Ed. Suction load up to 2,4 Pa Applied load up to 5,4 Pa L x B x D Connection technology Weight Detail view - mounting bore hole 168 x 99 x 4 mm (+/-2 mm) Cabels 2 x 1, m/4 mm², PV4 - Connector, Plug in arrangement analog MC4 appr. 24 kg Detail view - grounding bore hole * Approved stress loads (as per SOLARWATT Installation Instructions) for product version with additional feature crossrail : Applied load up to 5,5 Pa Test conditions: sliding load of 9, Pa (conditions take into account safety factors for snow overhang and ice load as per Eurocode 1) Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN Nominal power P N Nominal voltage U mpp Nominal current I mpp Open circuit voltage U OC Short circuit current I SC IR * SOLARWATT 6 P Wp 255 Wp 26 Wp 3,6 V 3,9 V 31,2 V 8,18 A 8,26 A 8,34 A 37,4 V 37,7 V 38, V 8,73 A 8,81 A 8,88 A Measurement tolerance in reference to Pmax ±5 %; Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation Nominal power P N Nominal voltage U mpp Nominal circuit voltage U OC Short circuit current I SC 2 A SOLARWATT 6 P 185 W 188 W 192 W 28,2 V 28,5 V 28,8 V 35, V 35,3 V 35,6 V 7,6 A 7,13 A 7,19 A Approved stress load as per SOLARWATT Installation Instructions Qualifications Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 26 Wp SOLARWATT 6P Is [A] W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m Thermal Features Us [V] Operating temperature range Ambient temperature range Temperature coefficient P N Temperature coefficient U OC Temperature coefficient I SC NOCT Applied load up to 3.5 Pa (when installed crosswise 1) ) Test condition: sliding load of 5,4 Pa (conditions take into account safety factors for snow overhang and ice load per Eurocode 1.) 1) Please refer to the specifications in the installation instructions. IEC Ed.2 IEC 6173 (including Protection Class II) 3 4 Is [A] Us [V] 7 C 5 C25 C C 3 4 Page 24 Back to the table of contents

25 Glass-glass module: SOLARWATT 36P new Alpine load-bearing capacity The innovative glass-glass generation Ultra-light weight thanks to glass just 2 mm thick Exceptionally reliable yield rates Improved mechanical strength 1 % protection against PID Increased fire protection SOLARWATT Service SOLARWATT Full Coverage included (up to 1, kwp) Straightforward returns policy as per the Terms of Delivery for Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " SOLARWATT 36P Guarantee of origin Quality from Germany Polycrystalline solar cells 15 Wp (1 % added sorting) Max 18 Pa* *Test conditions, see reverse of data sheet Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl resistant against ammonia resistant against hail resistant against salt mist Page 25 Back to the table of contents Item number Module type Power class (Wp) Modules per pallet Deviations from the standard scope of supply 4499 SOLARWATT 36P 15 3 Available as of 9/214 Services/qualifications

26 Technical Data Glass-Glass-Module: SOLARWATT 36P Dimensions General Data Module technology Glass- glass laminate, aluminum frame ,2 Typenschild inkl Seriennummer Covering material Encapsulation Backing material Solar cells High-transparency solar glass, 2 mm EVA-solar cells-eva, white Solar glass, 2 mm 36 polycristalline solar cells ±2 672 ±2 - + Cell dimensions Bypass diodes x 156 mm Application class Application class A (acc. to IEC 6173) Max. system voltage 1 V Mechanical Ratings as per IEC Ed. Suction load up to 1, Pa Applied load up to 18, Pa Detail view - mounting bore hole Detail view - grounding bore hole 152 ±2 Approved stress load as per SOLARWATT Installation Instructions Applied load up to 7,6 Pa (when installed crosswise 1) ) Test condition: sliding load of 18, Pa (conditions take into account safety factors for snow overhang and ice load per Eurocode 1.) 1) Please refer to the specifications in the installation instructions. L x B x D Connection technology Weight 1.52 x 672 x 4 mm (+/-2 mm) Cabels 2 x 1, m/4 mm², PV4 - Connector, Plug in arrangement analog MC4 appr. 15 kg Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN Nominal power P N Nominal voltage U mpp Nominal current I mpp Open circuit voltage U OC SOLARWATT 36P 15 Wp 17,9 V 8,39 A 22,4 V Qualifications Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 15 Wp SOLARWATT 36P Is [A] W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m Us [V] IEC Ed.2 IEC 6173 (including Protection Class II) 3 4 Is [A] Us [V] 7 C 5 C25 C C 3 4 Page 26 Back to the table of contents Short circuit current I SC 8,83 A IR * 2 A Measurement tolerance in reference to Pmax ±5 %; Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Thermal Features Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation Operating temperature range SOLARWATT 36P C SOLARWATT 36P Ambient temperature range C Nominal power P N 111 W Temperature coefficient P N -,34 %/K Nominal voltage U mpp 16,5 V Temperature coefficient U OC -,3 %/K Nominal circuit voltage U OC 21, V Temperature coefficient I SC,6 %/K Short circuit current I SC Solarunterstütze Energiesysteme SOLARWATT Energetische Bauliche Systeme 7,14 A SOLARWATT Bauliche Systeme SOLARWATT Solarmodule NOCT 45 C

27 Glass-glass module: SOLARWATT 36M glass / XL glass The innovative glass-glass generation SOLARWATT Service % transparency Exceptionally reliable yield rates Improved mechanical strength 1 % protection against PID Increased fire protection SOLARWATT Full Coverage included (up to 1, kwp) Straightforward returns policy as per the Terms of Delivery for Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " SOLARWATT 36M glass / XL glass Guarantee of origin Quality from Germany Monocrystalline solar cells 155 Wp (1 % added sorting) Max 6 Pa* AbZ Z General building authority approval *Test conditions, see reverse of data sheet Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl resistant against ammonia resistant against hail resistant against salt mist Page 27 Back to the table of contents Item number Module type Power class (Wp) Modules per pallet Deviations from the standard scope of supply 9443 SOLARWATT ORANGE 36M glass SOLARWATT ORANGE 36M glass On request 9446 SOLARWATT 36M XL glass Services/qualifications

28 Technical Data Glass-Glass-Module: SOLARWATT 36M glass/xl glass Dimensions 23, mm 61, mm 22, mm 35,5 mm 159, mm 73, mm 91, mm 52, mm 8,5 mm 24, mm General Data Module technology Covering material Encapsulation Backing material Glass-glass-laminate High-transparency floating glass, 4 mm EVA-solar cells-eva floating glass, 4mm Solar cells 36 monocrystalline solar cells Cell dimensions 156 x 156 mm Bypass diodes 2 71 mm min. R27mm 8 mm min. R27mm Application class Application class A (acc. to IEC 6173) Max. system voltage 1 V Mechanical Ratings as per IEC Ed. Suction load up to 2,4 Pa Applied load up to 6, Pa 152 mm 16 mm Anschlusstechnik Cable 2 x,4 m/4 mm², MC4-Connector SOLARWATT 36M glass SOLARWATT 36M XL glass Transparency 19 % 32 % L x B x D 152 ± 2 x 71 ± 2 x 9 ± 1 mm 16 ± 2 x 8 ± 2 x 9 ± 1 mm Weight appr. 25 kg appr. 29 kg Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN SOLARWATT 36M glass / XL glass Nominal power P N 145 Wp 15 Wp 155 Wp Nominal voltage U mpp 18,7 V 19, V 19,2 V Nominal current I mpp 7,76 A 7,9 A 8,8 A Open circuit voltage U OC 22,6 V 22,9 V 23,1 V Short circuit current I SC 8,15 A 8,31 A 8,5 A IR * 2 A Measurement tolerance in reference to Pmax ±5 %; Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation SOLARWATT 36M glass / XL glass Nominal power P N 16 W 11 W 114 W Nominal voltage U mpp 17,2 V 17,5 V 17,7 V Nominal circuit voltage U OC 21,1 V 21,4 V 21,6 V Short circuit current I SC Solarunterstütze Energiesysteme 6,58 A SOLARWATT Energetische Bauliche Systeme 6,71 A SOLARWATT Bauliche Systeme SOLARWATT 6,87 A Solarmodule Qualifications Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 155 Wp SOLARWATT 36M glass/ XL glass Is [A] W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m Thermal Features Us [V] Operating temperature range Ambient temperature range Temperature coefficient P N Temperature coefficient U OC Temperature coefficient I SC NOCT IEC Ed.2 IEC 6173 (including Protection Class II) 3 4 Is [A] Us [V] SOLARWATT 36M glass/ XL glass C C -,4 %/K -,32 %/K,5 %/K 45 C 7 C 5 C25 C C 3 4 Page 28 Back to the table of contents

29 Glass-film module: SOLARWATT BLUE 6M new Made in Dresden SOLARWATT BLUE 6M is also entirely produced in Germany. Standard warranty 1-year product warranty 25-year staggered performance warranty Extended warranty if SOLARWATT Full Coverage is purchased 12-year product warranty Linear 25-year performance warranty According to the "Special Warranty Conditions for SOLARWATT Modules" Max 54 Pa* *Test conditions, see reverse of data sheet SOLARWATT Service SOLARWATT Full Coverage optional (up to 1, kwp) Straightforward returns policy as per the Terms of Delivery for Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " Guarantee of origin Quality from Germany resistant against ammonia resistant against hail resistant against salt mist Page 29 Back to the table of contents Item number Module type Power class (Wp) Modules per pallet Deviations from the standard scope of supply 9272 SOLARWATT BLUE 6M SOLARWATT BLUE 6M Upon request Services/qualifications

30 Technical Data Glass-Foil-Module: SOLARWATT BLUE 6M Dimensions General Data Module technology Glass-foil-laminate; aluminium frame Erdungsbohrung 1 ±,5 mm Ø 9mm 168 ± 2 mm Covering material Encapsulation Backing material Solar cells High-transparency solar glass (tempered), 3,2 mm EVA-solar cells-eva, white Multi-layer composite film 6 monocrystalline solar cells Cell dimensions 156 x 156 mm Bypass diodes 3 Application class Application class A (acc. to IEC 6173) 99 ± 2 mm Max. system voltage Mechanical Ratings as per IEC Ed. 1 V Suction load up to 2,4 Pa Applied load up to 5,4 Pa Approved stress load as per SOLARWATT Installation Instructions Applied load up to 3.5 Pa (when installed crosswise 1) ) Test condition: sliding load of 5,4 Pa (conditions take into account safety factors for snow overhang and ice load per Eurocode 1.) 1) Please refer to the specifications in the installation instructions. L x B x D Connection technology Weight 168 x 99 x 4 mm (+/-2 mm) Cabels 2 x 1, m/4 mm², PV4 - Connector, Plug in arrangement analog MC4 appr. 19 kg Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN Nominal power P N Nominal voltage U mpp Nominal current I mpp Open circuit voltage U OC SOLARWATT BLUE 6 M 265 Wp 27 Wp 31,7 V 31,9 V 8,37 A 8,47 A 38,8 V 39,1 V Qualifications Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 27 Wp SOLARWATT BLUE 6M Is [A] W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m Us [V] IEC Ed.2 IEC 6173 (including Protection Class II) 3 4 Is [A] Us [V] 7 C 5 C25 C C 3 4 Page 3 Back to the table of contents Short circuit current I SC 8,93 A 9,1 A IR * 2 A Measurement tolerance in reference to Pmax ±5 %; Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Thermal Features Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation Operating temperature range SOLARWATT BLUE 6 M C SOLARWATT BLUE 6 M Ambient temperature range C Nominal power P N 195 W 199 W Temperature coefficient P N -,44 %/K Nominal voltage U mpp 29,3 V 29,4 V Temperature coefficient U OC -,34 %/K Nominal circuit voltage U OC 36,4 V 36,6 V Temperature coefficient I SC,4 %/K Short circuit current I SC Solarunterstütze Energiesysteme 7,21 A 7,28 A SOLARWATT Energetische Bauliche Systeme SOLARWATT Bauliche Systeme SOLARWATT Solarmodule NOCT 45 C

31 Glass-film module: SOLARWATT BLUE 6P Made in Dresden SOLARWATT BLUE 6P is also entirely produced in Germany. Standard warranty 1-year product warranty 25-year staggered performance warranty Extended warranty if SOLARWATT Full Coverage is purchased 12-year product warranty Linear 25-year performance warranty SOLARWATT Service SOLARWATT Full Coverage optional (up to 1, kwp) Straightforward returns policy as per the Terms of Delivery for Product warranty as per "Special Warranty Conditions for " Performance warranty as per "Special Warranty Conditions for " Guarantee of origin Quality from Germany According to the "Special Warranty Conditions for SOLARWATT Modules" Max 54 Pa* *Test conditions, see reverse of data sheet Product Quality long-lasting resilient high-yield innovative low-glare safe NH 3 NaCl resistant against ammonia resistant against hail resistant against salt mist Page 31 Back to the table of contents Item number Module type Power class (Wp) Modules per pallet Deviations from the standard scope of supply 9277 SOLARWATT BLUE 6P SOLARWATT BLUE 6P SOLARWATT BLUE 6P On request Services/qualifications

32 Technical Data Glass-Foil-Module: SOLARWATT BLUE 6P Dimensions General Data Module technology Glass-foil-laminate; aluminium frame Erdungsbohrung 1 ±,5 mm Ø 9mm 168 ± 2 mm Covering material Encapsulation Backing material Solar cells High-transparency solar glass (tempered), 3,2 mm EVA-solar cells-eva, white Multi-layer composite film 6 polycrystalline solar cells Cell dimensions 156 x 156 mm Bypass diodes 3 Application class Application class A (acc. to IEC 6173) 99 ± 2 mm Max. system voltage Mechanical Ratings as per IEC Ed. 1 V Suction load up to 2,4 Pa Applied load up to 5,4 Pa Approved stress load as per SOLARWATT Installation Instructions Applied load up to 3.5 Pa (when installed crosswise 1) ) Test condition: sliding load of 5,4 Pa (conditions take into account safety factors for snow overhang and ice load per Eurocode 1.) 1) Please refer to the specifications in the installation instructions. L x B x D Connection technology Weight 168 x 99 x 4 mm (+/-2 mm) Cabels 2 x 1, m/4 mm², PV4 - Connector, Plug in arrangement analog MC4 appr. 19 kg Electrical Data (STC) STC: Standard Test Conditions: Irradication intensity 1 W/m², spectral distribution AM 1.5 temperatur 25±2 C, in accordance EN SOLARWATT BLUE 6P Nominal power P N Nominal voltage U mpp Nominal current I mpp Open circuit voltage U OC Short circuit current I SC 245 Wp 3,1 V 8,14 A 37,4 V 8,57 A 25 Wp 3,2 V 8,28 A 37,6 V 8,69 A 255 Wp 3,4 V 8,39 A 37,8 V 8,77 A 26 Wp 3,6 V 8,53 A 38, V 8,86 A IR * 2 A Measurement tolerance in reference to Pmax ±5 %; Reduction of module efficiency when irradiance is reduced from 1 W/m² to 2 W/m² (at 25 C): 4 ± 2 % (relative) /,6 ±,3 % (absolute). * Reverse- current power rating: Operating modules with an external power source is only permissible if using a phase fuse with a tripping current of < 2 A. Electrical Data (NOCT) NOCT: Normal Operation Cell Temperature: Irradiation intensity 8 W/m², AM 1,5 temperatur 2 C, Wind speed 1m/s, open circuit operation Nominal power P N Nominal voltage U mpp Nominal circuit voltage U OC Short circuit current I SC SOLARWATT BLUE 6P 18 W 184 W 188 W 191 W 27,8 V 27,9 V 28,1 V 28,3 V 31,1 V 35,3 V 35,5 V 35,7 V 6,94 A 7,4 A 7,1 A 7,18 A Qualifications Characteristic Lines Voltage characteristic line at different temperatures and irradiation Performance class 27 Wp SOLARWATT BLUE 6P Is [A] W/m 2 8 W/m 2 6 W/m 2 4 W/m 2 2 W/m Thermal Features Us [V] Operating temperature range Ambient temperature range Temperature coefficient P N Temperature coefficient U OC Temperature coefficient I SC NOCT IEC Ed.2 IEC 6173 (including Protection Class II) 3 4 Is [A] Us [V] SOLARWATT BLUE 6P C C -,38%/K -,33 %/K,4 %/K 45 C 7 C 5 C25 C C 3 4 Page 32 Back to the table of contents

33 SOLARWATT StecaGrid system inverters 1-year guarantee included Quality for versatile use Lightweight, compact, no transformer Housing protection rating IP21 (indoor) Flexible input voltage range Maintenance-free Integrated network management and preparation of reactive power SOLARWATT Service SOLARWATT Full Coverage included (up to 1, kwp) Guarantee of origin Quality from Germany 1-year warranty included* Optimum efficiency (up to 98.6%)) Almost silent operation *Special warranty conditions by Steca Elektronik GmbH for SOLARWATT system inverter StecaGrid Scope of supply: Inverter, 1 x AC plug set, 1 x DC plug set (Sunclix), 1 x wall mount Page 33 Back to the table of contents Item number SOLARWATT system inverters Protection Rating AC output 5179 StecaGrid 18 IP kw 5171 StecaGrid 23 IP kw StecaGrid 31 IP21 3. kw StecaGrid 3 IP21 3. kw StecaGrid 36 IP kw StecaGrid 42 IP kw Services/qualifications

34 Technical Data SOLARWATT System Inverter DC input side (PV-generator) Maximum input voltage Minimum input voltage for feeding in MPP voltage for rated output Maximum input current 16-5 V 6 V 125 V 25-5 V 11,5 A 27-5 V 845 V 35 V 35-7 V 12 A 36-7 V Maximum input power at maximum active output power Maximum recommended PV power 1.84 W 2.2 Wp 2.35 W 2.9 Wp 3.7 W 3.8 Wp 3.6 W 3.8 Wp 3.69 W 4.5 Wp 4.31 W 5.2 Wp Number of DC inputs Number of MPP inputs 1 1 AC output side (Grid connection) Grid voltage V (depending on regional settings) Rated grid voltage 23 V Maximum output current 12 A 14 A 16 A 18,5 A Maximum active power (cos phi = 1) Maximum active power (cos phi =.95) Maximum apparent power (cos phi =.95) Rated power 1.8 W 1.8 W 1.9 VA 1.8 W 2.3 W 2.3 W 2.42 VA 2.3 W 3. W 3. W 3.16 VA 3. W 3. W 3. W 3.13 VA 3. W 3.6 W 1) 3.53 W 3.68 VA 3.6 W 2) 4.2 W 1) 3.99 W 4.2 VA 4.2 W 3) Rated frequency 5 Hz and 6 Hz Frequency 45 Hz - 65 Hz (depending on regional settings) Night-time power loss < 1,2 W <,7 W Feeding phases single-phase Distortion factor (cos phi = 1) Power factor cos phi < 2 %,95 capacitive -,95 inductive Characterisation of the operating performance Maximum efficiency 98 % 98,6 % European efficiency Californian efficiency 97,4 % 97,5 % 97,6 % 97,7 % 97,7 % 97,8 % 98,3% 98,4 % 98,3 % 98,3 % 98,2 % 98,2 % MPP efficiency > 99,7 % (static), > 99 % (dynamic) Own consumption < 4 W Power derating at full power Safety Isolation principle Grid monitoring StecaGrid 18 from 5 C (Tamb) StecaGrid 23 from 5 C (Tamb) StecaGrid 31 from 45 C (Tamb) StecaGrid 3 from 5 C (Tamb) no galvanic isolation, transformerless yes, integrated StecaGrid 36 from 5 C (Tamb) StecaGrid 42 from 45 C (Tamb) StecaGrid 18 StecaGrid StecaGrid 31 StecaGrid 3 StecaGrid StecaGrid 42 Operating conditions Area of application indoor rooms with or without air conditioning Ambient temperature -15 C up to +6 C Storage temperature -3 C up to +8 C Relative humidity % up to 95 % (non-condensating) Noise emission (typical) Fitting and construction 23 dba 25 dba 29 dba 26 dba 29 dba 31 dba Degree of protection IP 21 (casing: IP 51; display: IP 21) Overvoltage category DC Input side connection III (AC), II (DC) Phoenix Contact Sunclix (1 pair) AC output side connection Wieland RST25i3 plug, mating connector included Dimensions (X x Y x Z) 34 x 68 x 222 mm Weight 9,5 kg 9 kg Communication interface RS485; 2 x RJ45 sockets Integrated DC circuit breaker yes, compliant with VDE Cooling principle Cooling principle temperature-controlled fan, variable speed Test certificate CE mark, VDE AR N 415, G83, CEI -21 Under preparation: UTE C Dimensions CE mark, VDE AR N 415, G83, UTE C , AS4777, CEI CE mark, VDE AR N 222 CE mark, VDE AR N 415, G83, CEI -21 Page 34 Back to the table of contents Residual current monitoring yes, integrated 4) 1) Belgium: 3.33 W 2) Portugal: 3.45 W 3) Portugal: 3.68 W 4) The design of the inverter prevents it from causing DC leakage current.

35 Inverter layout software new SOLARWATT Scout The following functions are also included: Anyone interested in planning a SOLARWATT PV system with grid connection is optimally equipped with SOLARWATT Scout. With SOLARWATT Scout all system components can be optimally calibrated to one another. SOLARWATT Scout uses all current data records of SOLARWATT modules and StecaGrid system inverters. Irradiation values with precision down to the exact minute enable the planned PV system to be calculated perfectly. Change in location Inverter selection Consideration of irradiation in locations around the world Freely definable roof drawings thanks to a user-friendly interface Customizable representation of circuit diagrams, DC connection diagrams Export/print function for all planning results Online updating SOLARWATT can be downloaded from My SOLARWATT at Page 35 Back to the table of contents Roof selection Roof design Services/qualifications

36 Steca inverter Item number Device type Protection Rating AC output Figure Description Steca coolcept-x StecaGrid 18x IP kw Single-phase mains inverter Consumer test winner with optimum efficiency and long StecaGrid 23x IP kw service life (peak efficiency of 98.6 %) 5-year warranty (free warranty extension to 7 years after registration) StecaGrid 31x IP65 3. kw Easy installation thanks to compact design and max. weight StecaGrid 36x IP kw of 12 kg; low enclosure temperature even at full capacity; sealed, dust-protected stainless steel enclosure; for indoor and outdoor installation; German-made StecaGrid 42x IP kw Steca coolcept 3 and coolcept-x StecaGrid 323 IP21 3.2kW StecaGrid 43 IP21 4.kW StecaGrid 483 IP21 4.8kW StecaGrid 553 IP21 5.5kW StecaGrid 323x IP65 3.2kW StecaGrid 43x IP65 4.kW New 3-phase Three-phase mains inverter (peak efficiency: 98.6 %), 5-year warranty (warranty extension to 7 years free of charge after registration), simple installation with compact construction and a max. weight of 12 kg, low housing temperatures even at full load, available for indoor and outdoor installation, Made in Germany Page 36 Back to the table of contents StecaGrid 483x IP65 4.8kW StecaGrid 553x IP65 5.5kW 5162 StecaGrid 8+ 3ph IP54 8. kw - Three-phase mains inverter, outdoor-compatible IP StecaGrid 1+ 3ph IP54 1. kw - Services/qualifications

THERMAL CHARACTERISTICS Nominal operating cell temperature(noct) [ C] 48,2±2 48 Temperature coefficient P MPP [%K] -0,41-0,47 Temperature coefficient I SC [%K] 0,05 0,04 Temperature coefficient U OC [%K]

More information

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges

More information

SUNNY TRIPOWER 5000TL 12000TL

SUNNY TRIPOWER 5000TL 12000TL SUNNY TRIPOWER 5000TL 12000TL STP 5000TL-20 / STP 6000TL-20 / STP 7000TL-20 / STP 8000TL-20 / STP 9000TL-20 / STP 10000TL-20 / STP 12000TL-20 NEW available as 10 kva and 12 kva versions Economical Flexible

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready / Battery Charging Systems / Welding Technology / Solar Electronics FRONIUS IG PLUS / The allrounder with maximum yield. / Fronius MIX technology / HF transformer switchover / PC board replacement process

More information

PREMIUM CLASS PHOTOVOLTAICS

PREMIUM CLASS PHOTOVOLTAICS PREMIUM CLASS PHOTOVOLTAICS ENGLISH A CNBM COMPANY PREMIUM CLASS PHOTOVOLTAICS Our successful flagship is the brand PowerMax. PowerMax modules offer a high energy yield (kwh per kwp), possible due to broad

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

ADDENDUM #1(BID PACKAGE # 3)

ADDENDUM #1(BID PACKAGE # 3) H2Engineering, Inc. 114 East Fifth Avenue Tallahassee, FL 32303 Phone 850.224.7922 Fax 850.224.5876 ADDENDUM #1(BID PACKAGE # 3) To: Jeff Williams From: Peter Lindstrom Co: Leon County Date: October 04,

More information

ASI OEM Outdoor Solar Modules

ASI OEM Outdoor Solar Modules SOLAR PHOTOVOLTAICS ASI OEM OUTDOOR E ASI OEM Outdoor Solar Modules for innovative autarchic electronic devices More Energy Double-stacked cells Stable performance Reliability and Quality Made in Germany

More information

SolarMax P series The power package for residential solar plants

SolarMax P series The power package for residential solar plants SolarMax P series The power package for residential solar plants The future-proof solution The requirements for residential photovoltaic plants have increased continuously in the past years. Due to our

More information

SYSTEM MONITORING Locally and remotely

SYSTEM MONITORING Locally and remotely StecaGrid 300 StecaGrid 500 StecaGrid 2000+ StecaGrid 2010+ StecaGrid 2020 StecaGrid 3000 StecaGrid StecaGrid 4200 StecaGrid StecaGrid 10000+ 3ph StecaGrid 8000 3ph StecaGrid 10000 3ph monitoring StecaGrid

More information

ENGLISH PV GRID CONNECTED

ENGLISH PV GRID CONNECTED ENGLISH PV GRID CONNECTED 2 3»Power from the sun for everyday use.«in one hour, the amount of energy radiated to the earth by the sun exceeds the annual energy requirement of the world population. Making

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

How To Make A Fronius Cl Power Inverter

How To Make A Fronius Cl Power Inverter Fronius CL PV central inverter with Fronius MIX concept Modular system. Maximum yield. The Fronius CL combines high-yield power electronics with the unique, modular system design of up to 15 identical

More information

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE Perfect Welding Solar Energy Perfect Charging FRONIUS ENERGY PACKAGE The personal storage solution for 24H Sun. PC board replacement process SnapINverter technology Integrated data communication Dynamic

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Your Sharp system will be supplied with one of the following sets of panels:

Your Sharp system will be supplied with one of the following sets of panels: Sharp3000 3kW Solar System Panel Specifications Your Sharp system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum 3000

More information

Fronius IG Plus. The next generation grid-connected PV inverter

Fronius IG Plus. The next generation grid-connected PV inverter Fronius IG Plus The next generation grid-connected PV inverter Maximum energy harvest cloudy or clear The first complete inverter solution. Reliable. Proven. Smart. An outstanding addition to the family:

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

DIGITUS Network & Server Cabinets. UNIQUE Series

DIGITUS Network & Server Cabinets. UNIQUE Series DIGITUS Network & Server Cabinets UNIQUE Series Benefits - Server Rack 4-Point locking system front door 3-point locking system rear door Swing handle lock with profile zylinder in front and rear door

More information

Operating Manual UWAPS-TINY Series

Operating Manual UWAPS-TINY Series Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4

More information

Sunny Family 2012 PRODUCT CATALOG

Sunny Family 2012 PRODUCT CATALOG Sunny Family 2012 PRODUCT CATALOG » Although each PV plant is unique, SMA has the right solution for all demands. SUNNY BOY 1.6 to 5 kw SUNNY MINI CENTRAL 5 to 11 kw SUNNY TRIPOWER 10 to 20 kw SUNNY CENTRAL

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

We're with you... solar. Call 1800 332 332 today FOR THE LIFE OF THE SYSTEM YEAR WARRANTY * YEAR OLD BACKED BY CSR BRADFORD CSR A AUSTRALIAN COMPANY

We're with you... solar. Call 1800 332 332 today FOR THE LIFE OF THE SYSTEM YEAR WARRANTY * YEAR OLD BACKED BY CSR BRADFORD CSR A AUSTRALIAN COMPANY We're with you... FOR THE LIFE OF THE SYSTEM 25 YEAR WARRANTY * Electricity prices are predicted to continue to rise in the future. If you're serious about installing energy in your home, look no further

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list

SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list SOLAR MODULES SOLARFLEX Polska Grupa Inwestycje Ekologiczne Sp. z o.o. PRODUCTS LINE of SOLARFLEX Price list Nr Indeks Type of modules Set components Peak Power [Pmax] Net price 1 SOLARFLEX 36W Flex flexible

More information

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES GENERAL INSTALLATION MANUAL FOR EGING PV MODULES PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR USING THE MODULES. PLEASE PASS ALONG THE ATTACHED USER MANUAL TO YOUR CUSTOMER. 1. INTRODUCTION This

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Phoenix Solar AG. Phoenix TectoSun 3 Installation instructions

Phoenix Solar AG. Phoenix TectoSun 3 Installation instructions AG Phoenix TectoSun 3 Installation instructions 2 THE TECTOSUN 3 MOUNTING SYSTEM FROM PHOENIX SOLAR THE ADVANTAGES AT A GLANCE Tested by TÜV, RAL seal of uality for all components Quick and easy installation

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Design qualification and type approval of PV modules

Design qualification and type approval of PV modules Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance

More information

ABB central inverters PVS800 100 to 1000 kw

ABB central inverters PVS800 100 to 1000 kw Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

Inverters. The product range.

Inverters. The product range. s. The product range. Brings more sun to the grid. Energy efficiency as a philosophy. What drives the company. Diehl Controls, a division of the Diehl Group, is home to the Diehl AKO, PLATINUM and Diehl

More information

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. 56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000 Photovoltaic Inverter Specification Version 2.06 1500 2000 3000 4000 5000 Kinglong New Energy Technology Co.Ltd. Kinglong New Energy Technology Co.Ltd. specification 1.1. Introduction... 3 1.1.1. Environment...

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar

Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

46120-F0 Solar Energy Training System

46120-F0 Solar Energy Training System 46120-F0 Solar Energy Training System LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2016 Table of Contents General Description 2 List of Equipment 2 List of Manuals 3 Table of Contents of

More information

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications ANTENERGY Powered By BOSCH Cells Portable Solar Panel Kit User Manual and Product Specifications IMPORTANT Read instructions before operation. 1 / 12 Index Getting to know your Portable Solar Panel Kit

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

Romana Brentgens / photon-pictures.com (2)

Romana Brentgens / photon-pictures.com (2) science & technology inverters test Simple design both inside and out: The results of thermographic imaging were impressive there were only two areas where temperatures were elevated, but they were still

More information

HORIZONTAL INSTALLATION

HORIZONTAL INSTALLATION THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Model CS 64 Mini-DIN Cable and Adaptor

Model CS 64 Mini-DIN Cable and Adaptor Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink

More information

Wind Sensor W-RS485 with RS485 Interface

Wind Sensor W-RS485 with RS485 Interface Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93

More information

Transformerless PV inverter withstandardsystem monitoring. Fronius IG TL

Transformerless PV inverter withstandardsystem monitoring. Fronius IG TL Fronius IG TL Transformerless PV inverter withstandardsystem monitoring Pluginthe future. Lockinyour yield. The consistent expansion ofasuccessful family: The Fronius IG TL incorporates all the advantages

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control

More information

0845 0098 980 www.nicholsonsts.com

0845 0098 980 www.nicholsonsts.com 0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

PV module safety qualification according to IEC 61730:2004 EN 61730:2007 PV module safety qualification according to IEC 61730:2004 EN 61730:2007 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies January 2009 Version 2009-01-22 Overview The long term

More information

sunmax Residential Solar Solution sunmax Hardware sunmax Software

sunmax Residential Solar Solution sunmax Hardware sunmax Software DATASHEET sunmax Residential Solar Solution The sunmax Residential Solar Solution provides a complete product solution including hardware and software. The sunmax hardware offers advantages such as simplified

More information

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies 2009-01-22 January 2009 Design qualification

More information

Solar Inverters Product Catalogue. Solar inverters, monitoring and support for residential / commercial installations and power plants

Solar Inverters Product Catalogue. Solar inverters, monitoring and support for residential / commercial installations and power plants Solar Inverters Product Catalogue Solar inverters, monitoring and support for residential / commercial installations and power plants EU Content About us 2 SOLIVIA - Solar inverters 4 Solar inverters

More information

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010 How do I determine the PTC rating of a module? PTC refers to PVUSA Test Conditions, which were developed to test and compare

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and

More information

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,

More information

YSmart Technology Co.,Ltd

YSmart Technology Co.,Ltd YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,

More information

Hammarby Sjöstad Kv Lugnvattnet PV-Project: "Lysande"

Hammarby Sjöstad Kv Lugnvattnet PV-Project: Lysande Hammarby Sjöstad Kv Lugnvattnet PV-Project: "Lysande" TECHNICAL DESCRIPTION PV System TENDER DOCUMENT Stockholm 2002-03-15 Created by: Jonas Hedström, Energibanken i Jättendal AB 1 Tender document for

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Knürr Smaract. Knürr Smaract. CompactRack

Knürr Smaract. Knürr Smaract. CompactRack CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

YINGLI SOLAR PV MODULES Installation and User Manual

YINGLI SOLAR PV MODULES Installation and User Manual YINGLI SOLAR PV MODULES Installation and User Manual Revision Date December 24, 2011 Applicable for IEC certified products This manual applies to photovoltaic modules ( PV modules, also commonly known

More information

INSTALLATION MANUAL FOR PV MODULES ENGLISH VERSION 01 - SEPTEMBER 2013. www.ldksolar.com

INSTALLATION MANUAL FOR PV MODULES ENGLISH VERSION 01 - SEPTEMBER 2013. www.ldksolar.com INSTALLATION MANUAL FOR PV MODULES ENGLISH VERSION 01 - SEPTEMBER 2013 1 Installation Manual ENGLISH 1. Introduction This manual contains information regarding the safe installation and handling of photovoltaic

More information

Application Note: String sizing Conext CL Series

Application Note: String sizing Conext CL Series : String sizing Conext CL Series 965-0066-01-01 Rev A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This Application Note is in addition to, and incorporates by reference, the installation

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

AA Solar and Sun Power Plus

AA Solar and Sun Power Plus AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools

More information

SOLAR ChARge CONTROLLeRS

SOLAR ChARge CONTROLLeRS Steca Tarom MPPT 6000, 6000-M The Steca Tarom MPPT solar charge sets new standards in the area of Maximum Power Point trackers. Outstanding efficiency along with unique safety features make it a universal

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS 1. Standards BOS Item / System I ii iii TECHNICAL SPECIFICATIONS Applicable BIS /Equivalent IEC Standards / Applicable MNRE Specifications Standard Description Standard Number Crystalline Silicon Terrestrial

More information

245-310 W POWER OUTPUT RANGE

245-310 W POWER OUTPUT RANGE Mono Multi Solutions THE OPTIMIZED SOLUTION COMPTIBLE WITH MOST TRIN MODULES Safer Solar Panel-level disconnect to remotely deactivate modules rc, fire and safety hazard mitigation 245-310 W POWER OUTPUT

More information

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET FOR IMMEDIATE RELEASE No. 2387 Product & Catalogue Inquiries: Media Contact Naoto Shimada Travis Woodward Nakatsugawa Works Public Relations Department Photovoltaic Power System Business Center Mitsubishi

More information

Building Integrated Photovoltaic (BIPV)

Building Integrated Photovoltaic (BIPV) Building Integrated Photovoltaic (BIPV) Jan-Willem Tolkamp, International Account Manager BIPV Solar power on buildings' conference, 20th October 2010 see it. feel it Index 1. From PV to BIPV 2. The BIPV

More information

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

TABLE OF CONTENTS SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7 2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Fronius IG Plus. The next generation grid-connectedpvinverter.

Fronius IG Plus. The next generation grid-connectedpvinverter. Fronius IG Plus The next generation grid-connectedpvinverter. Maximumearnings. Inanyweather. The first multi-purpose device. Reliability and maximum earnings security. An outstanding addition to the family:

More information

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw

ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw Solar inverters ABB central inverters PVI-55.0/110.0 - PVI-165.0/220.0 - PVI-275.0/330.0 55 to 330 kw ABB s central inverters are extremely scalable, modular-inverter systems that are based on 55kW modular

More information

Prism Solar Installation Manual

Prism Solar Installation Manual This installation manual applies to the following Prism Solar bifacial glass/glass models: B265(L), B260, B255, B250, B245, B200, B150, HB180. IMPORTANT: Read these instructions and the Prism Solar Design

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

A sophisticated design for a demanding field. prima series

A sophisticated design for a demanding field. prima series A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally

More information

Long-term performance of photovoltaic modules Artur Skoczek

Long-term performance of photovoltaic modules Artur Skoczek 1 Long-term performance of photovoltaic modules Artur Skoczek 2 The European Solar Test Installation (ESTI) has the primary objective of providing the scientific and technological basis for a sound and

More information

SANS 1 0 1 7 7-9. www.spunchem.com FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/366 2009/367 2009/369 2008/341

SANS 1 0 1 7 7-9. www.spunchem.com FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/366 2009/367 2009/369 2008/341 REFLECTIVE ENERGY SAVER FIRE PERFORMANCE SANS 428 SANS 1 0 1 7 7-9 SANS 10177-10 SANS 10177-11 www.spunchem.com A MEMBER OF TIASA Thermal Insulation Association of Southern Africa 2009/66 2009/67 2009/69

More information

SUNNY BOY 2000HF / 2500HF / 3000HF

SUNNY BOY 2000HF / 2500HF / 3000HF SUNNY BOY 2000HF / 2500HF / 3000HF A New Dimension SUNNY BOY 2000HF / 2500HF / 3000HF A NEW DIMENSION AMAZINGLY SIMPLE. REASSURINGLY EFFICIENT. Do you want promising prospects? Then the Sunny Boy HF is

More information