Data Centre Regulation

Size: px
Start display at page:

Download "Data Centre Regulation"

Transcription

1 WPs 2.1, 2.2, 2.3, 2.4, 2.5 Graeme Maidment

2 i-stute cooling based projects WP2.1. and WP2.2 Supermarket refrigeration Cost of ownership WP2.3. Data centres Integration Carbon/ energy WP2.4. Transport refrigeration WP2.5. Integrated heating and cooling Materials, resources & waste

3 Background WP 2.1 and 2.2 Retail refrigeration 40-70% of energy in supermarkets used for refrigeration UK retail refrigeration ~ 9-10 TWh/year ~75% chilled, ~25% frozen 1.5% of UK energy used by retail ~7.3 Mt CO2 (~26% direct, ~74% indirect) Temperature control, carbon emissions increase at consumer end of cold chain Deliverables Refrigeration road map State of the art display cabinet 1

4 WPs WP 2.1 Retail chilling and freezing WP2.1.1 Technologies will be initially investigated and sifted WP2.1.2 In parallel with WP2.1 technologies will be investigated with a proof of concept prototype WP2.1.3 Non technical barriers preventing uptake, will be assessed ie customer reaction, implementation, cost-benefit, incentives WP2.1.4 A trial of the prototype in-store with ASDA

5 Technologies investigated 77 technologies evaluated at last meeting New technologies added: Ejectors Flooded evaporators 2-stage compression Turbine expansion machines Fan motor outside cabinet Lights outside cabinet Defrost drain traps Integral distributed system Thermostatic flow control Air deflectors/guides Improved axial fans Diagonal fans Defrosts (additional information) Dual port TEV/TXV Glazing (additional information) Efficient HE design Hydrophilic and hydrophobic coating on evaporator

6 Supermarket model further developed Store modelled - ASDA Weston- Super-Mare Typical large supermarket Model can be adapted to different store sizes and configurations Further information obtained from City Holdings (ASDA contractors) However, stalled recently due to contact leaving company The model

7 Results

8 Results Emissions per year: Direct = tco 2e Indirect = tco 2e Ratio indirect : direct = 1.1 High direct as very high refrigerant charge (~1000 kg in cabinet circuits) Leakage rate medium (~10% per year) Therefore effect of changes to refrigerant have high impact on CO 2e emissions

9 DIRECT EMISSIONS Results

10 INDIRECT EMISSIONS Results

11 DIRECT (grey bubble) AND INDIRECT EMISSIONS (open bubble) Results

12 Next steps Need further data and clarification from ASDA: Cooking appliances Some costs for applying technologies Some data still is not logical Based on current information possible to halve emissions with paybacks of less than 3 years If technologies with less than 3 year paybacks were applied and assuming application of: Cheapest options with best paybacks Minimum savings applied Simplest option (where more than one option available) the carbon savings would be: ~50-65%

13 WP2.1 Deliverables Contact with CSEF, agreed to create dynamic supermarket model with team at Brunel Keynote for ICEF12 (Quebec) Opportunity to publish book from road map work Peer reviewed paper on technological options (IJR)

14 WP2.3 - Data Centre Cooling Background Data centres currently account for approx. 2-3% of total electricity consumption in the UK Typically, approx. 50% of data centre energy is used for cooling and humidification Data centres are generally air cooled and the heat dissipated to ambient Limited focus on heat recovery Deliverables Roadmap/report on cooling Detailed investigation - integrated cooling, heat recovery and heat transfer. 14

15 Roadmap There are 4 main approaches to data centre cooling: Remote air cooling: - Using CRACs or CRAHs/chilled water. Also air and water economisation Local air cooling: - Close coupled cooling e.g. rack rear door chilled water heat exchanger Direct liquid on-chip cooling: - Water or dielectric cold plate heat exchanger in direct contact with electronic components Total immersion liquid cooling: - Whole server board immersed in dielectric liquid 15

16 Roadmap Comparison of 4 main cooling approaches: Cooling Method Remote air Local air Liquid directto-chip Liquid immersion Characteristics Coolant(s) (P) Air (P) Air (P) 60/70% Liq (S) R/G/W/Chw (S) Chw (P) 30/40% Air (P)100% Liq Typical inlet-return Air: C Air: C Liq:40-60 C temperatures Chw:10-20 C Chw:10-20 C Air: C Liq: C Heat capacity of primary coolant Low Low High High T Chip to coolant High High Low Low Heat recovery Air Air Air possible? Chw Chw Liq Liq Heat reuse value Low Low High High 16

17 Future trends: Roadmap 1. Increasing data centre efficiency: - Growth in data centre capacity, size and processing speed to meet user needs big data, internet of things (IoT). - Increasing numbers of high performance computing (HPC) and hyperscale servers, and development of exascale data centres 2. Greater utilisation of IT server resources: - Increased IT work levels, server consolidation and virtualisation, move to cloud - Software defined data centres (SDDC) 3. Chip and server architecture development: - Further miniaturisation of ICs down to 1 nm scale by 2020s - Adoption of 3D architecture e.g. vertical chip stacking with microchannel liquid cooling, especially for memory chips Microliquid heat sinks between 17 stacked dies

18 Data centres and District heating networks Currently supply only 2% of heat demand in UK by district heating UK government plans to substantially expand district heating networks making use of waste heat sources e.g. data centres London plans to build a low temperature heat network supply temperature 70 C (London Mayor reports, 2012; 2013) Data centre waste heat could be upgraded via heat pumps to contribute heat at this temperature 18

19 Distribution of data centres across UK Largest number of (colocation) data centres is in London (approx 75) Majority are concentrated in central London, along the Thames 19

20 London heat use and district heating networks (Map from: map/) Yellow lines indicate existing heat networks, red lines indicate proposed heat networks (Map from: 20

21 Detailed investigation of cooling and waste heat recovery in data centres Objectives: To construct a test facility to simulate a conventional IT server rack (~5kW) To investigate a range of cooling methods, environmental conditions and waste heat recovery systems To evaluate the quantity and quality of recovered waste heat, for different cooling methods To investigate the carbon and cost implications of increasing waste heat temperature to e.g. 70 C using heat pumps 21

22 Details of IT server rack test facility 1 x 42U standard server rack ~2 m (h) x 0.6 m (w) x 1.07 m (d) 42 x 1U servers, total weight approx. 500 kg (10-15 kg per server) Linux operating system and benchmarking software to provide adjustable, constant heat generation for all servers IT servers instrumented with thermocouples, velocity and humidity sensors. Measurement of total energy input to servers and cooling equipment and heat recovered 22

23 Next steps Activities Duration Deliverables Due date Finalise, format and publish roadmap report Publish journal paper on waste heat recovery from data centres Construct data centre test facility and commission Experimental testing of cooling and heat recovery methods May- June 2015 Roadmap report 1 st July 2015 May-June 2015 Journal paper 1 st July 2015 May-Dec 2015 Dec 2015-end of project Operational facility Report on test facility construction First interim report Additional interim reports Final report 1 st Dec st Feb st May 2016 TBC End of project 23

24 WP 2.3 Deliverables Internal report on cooling of data centres October 2014 Initial internal heat recovery report December 2014 Report/roadmap of Future technologies with input from Robert Tozer March 2015 Dissemination paper on data centre waste heat recovery to be presented to CIBSE technical symposium April 2015 at UCL Journal paper on heat recovery drafted Detailed heat recovery study commences January 2016

25 WP2.4 refrigerated road transport (RRT) Background UK primary food distribution by RRT uses 40% more energy than non-refrigerated vehicles Environmental Impact Indirect emissions - Transportation - 2 Mtonnes of indirect CO 2 emissions from the engine alone. Refrigeration -???? Direct emissions - RRT units leak up to 30% of their total refrigerant charge per year System Durability & Reliability Deliverables Development of a model to investigate direct and indirect emissions Optimising system performance

26 Research Plan 1. Investigate different types RRT vehicle technologies 2. Analyse maintenance and leakage records to: a) Identify problematic components/ sources of refrigerant leakage b) Suggest generic solutions for leak tight systems 3. Develop a model to; a) Estimate direct/ indirect carbon emissions b) Evaluate the effectiveness of various concepts 4. Measure actual RRT data 5. Validate and optimise model 6. Industry report & PhD thesis 26

27 Project Plan flow chart PhD Thesis Conduct Prelim Study & Data Analysis I Develop Model Collect Data & Analyse Validate & Optimize Model Report for Transport Industry 27

28 Model Development Refrigeration Performance 2. A preliminary model to predict the performance of RRT systems has been developed. MS Excel Mathematical model Focuses on typical last-mile RRT vehicle (i.e. small vans to medium rigid refrigerated trucks) used for urban distribution. 28 Calculates relative proportion of various refrigeration heat loads and corresponding indirect carbon emissions: i. Wall transmission ii. Natural infiltration due to gaps, cracks iii. Door infiltration iv. Product load v. Other loads such as evaporator fans

29 Refrigeration Performance Model - System Details 29

30 Challenges and Solutions Common solutions include: Oversize unit; use door protection; employ a hybrid system Planned approach: Determine optimum design For the average load profile Typical annual duty cycle 30 Issues with direct drive RRT units: Large amount of heat entering during door openings Refrigeration system stop working when vehicle stops => system is off when load at its highest Running time between stops may be short => time insufficient for temp pull-down

31 Project Schedule Today Develop Model - May Jan 2016 Data Collection - Meeting with Fleet Owner (Data Supplier) May 2015 Initiate data collection Jun 2015 Data Analysis- Aug Jan

32 WP 2.4 Deliverables Internal report on leakage - Feb 2014, August 2014 LSBU Registration document -RES2 June 2014 Summer school conference June 2014, June 2015 Internal report on modelling platforms- August 2014 LSBU Literature review internal report-res 3B Oct 2014 Internal report on modelling platforms- August 2014, Nov 2014 Ethics application approval -Jan 2015 LSBU Annual Report RES 4 April 2015 Impact Hubbard have changed their system design to minimize leakage.

33 Background To investigate the interactions of underground railway tunnels and ground heat exchangers To investigate the potential indirect use of waste heat from the tunnels to heat buildings above ground. Deliverables Development of a model Case study materials INTERACTIONS

34 2. Project time line with the key milestones Stage 1 & 2 Stage 3 Stage 4 Stage 6 Stage 7 Currently ongoing

35 Results Figure 1 Annual temperature distribution within soil Figure 3 Numerically simulated tunnel and ground surface temperatures Figure 2 BHE wall temperatures versus tunnel proximity

36 WP 2.5 Deliverables Internal reports April July and November 2014, February 2015 Summer school conference, Poster June 2014 Registration document RES2 September 2014 Literature review internal report October 2014 Internal report on modelling platforms - November 2014 Registration document RES3 February 2015 Conference paper submission February 2015 Manuscript submission to a Journal March 2015 Registration document RES4 March 2015

37 Questions

Opportunities for Combined Heating and Cooling Using Data Centres

Opportunities for Combined Heating and Cooling Using Data Centres Opportunities for Combined Heating and Cooling Using Data Centres Gareth Davies School of the Built Environment and Architecture, London South Bank University 103 Borough Road, London SE1 0AA Email: daviesg@lsbu.ac.uk

More information

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015 I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 8, Loughborough University, 29 th June 2015 Topics to be considered 1. Progress on project tasks 2. Development of data centre test facility

More information

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 4, Lancaster University, 2 nd July 2014 I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 4, Lancaster University, 2 nd July 2014 Background Data centres estimated to use 2-3% of total electricity consumption in the UK and generate

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London. Energy Efficient Data Centre at Imperial College M. Okan Kibaroglu IT Production Services Manager Imperial College London 3 March 2009 Contents Recognising the Wider Issue Role of IT / Actions at Imperial

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres

Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres School of something School of Mechanical Engineering FACULTY OF OTHER ENGINEERING Computational Fluid Dynamic Investigation of Liquid Rack Cooling in Data Centres A. Almoli 1, A. Thompson 1, N. Kapur 1,

More information

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy

More information

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Legacy Data Centres Upgrading the cooling capabilities What are the options? Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems

More information

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale

More information

Blade Server & Data Room Cooling Specialists

Blade Server & Data Room Cooling Specialists SURVEY I DESIGN I MANUFACTURE I INSTALL I COMMISSION I SERVICE SERVERCOOL An Eaton-Williams Group Brand Blade Server & Data Room Cooling Specialists Manufactured in the UK SERVERCOOL Cooling IT Cooling

More information

News in Data Center Cooling

News in Data Center Cooling News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase

More information

FROST PREDICTION ON EVAPORATOR COILS OF SUPERMARKET DISPLAY CABINETS USING ARTIFICIAL NEURAL NETWORKS

FROST PREDICTION ON EVAPORATOR COILS OF SUPERMARKET DISPLAY CABINETS USING ARTIFICIAL NEURAL NETWORKS FROST PREDICTION ON EVAPORATOR COILS OF SUPERMARKET DISPLAY CABINETS USING ARTIFICIAL NEURAL NETWORKS D. Datta and S. A. Tassou Department of Mechanical Engineering, Brunel University Uxbridge, Middlesex

More information

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building

More information

University of St Andrews. Energy Efficient Data Centre Cooling

University of St Andrews. Energy Efficient Data Centre Cooling Energy Efficient Data Centre Cooling St. Andrews and Elsewhere Richard Lumb Consultant Engineer Future-Tech Energy Efficient Data Centre Cooling There is no one single best cooling solution for all Data

More information

European Business Reliance Centres when Commodity serves Green IT

European Business Reliance Centres when Commodity serves Green IT European Business Reliance Centres when Commodity serves Green IT www.ebrc.com www.trusteddatacentre.com www.trustedcloudeurope.com www.trustedmanagedservices.com ebrc COMPANY PROFILE 5 datacenters = 17.000

More information

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries

More information

HPC TCO: Cooling and Computer Room Efficiency

HPC TCO: Cooling and Computer Room Efficiency HPC TCO: Cooling and Computer Room Efficiency 1 Route Plan Motivation (Why do we care?) HPC Building Blocks: Compuer Hardware (What s inside my dataroom? What needs to be cooled?) HPC Building Blocks:

More information

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre

Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre S. Luong 1*, K. Liu 2, James Robey 3 1 Technologies for Sustainable Built Environments, University of Reading,

More information

Analysis of data centre cooling energy efficiency

Analysis of data centre cooling energy efficiency Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe

More information

Server room guide helps energy managers reduce server consumption

Server room guide helps energy managers reduce server consumption Server room guide helps energy managers reduce server consumption Jan Viegand Viegand Maagøe Nr. Farimagsgade 37 1364 Copenhagen K Denmark jv@viegandmaagoe.dk Keywords servers, guidelines, server rooms,

More information

DataCenter 2020: first results for energy-optimization at existing data centers

DataCenter 2020: first results for energy-optimization at existing data centers DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction

More information

Data Centre Cooling Air Performance Metrics

Data Centre Cooling Air Performance Metrics Data Centre Cooling Air Performance Metrics Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. info@dc-oi.com Abstract Data centre energy consumption

More information

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS

ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS ADVANCES IN SUPERMARKET REFRIGERATION SYSTEMS Van D. Baxter, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6070 ABSTRACT Present supermarket refrigeration systems require very large refrigerant charges

More information

10 Strategic Steps to Reducing Your Energy Costs AEE Regional Chapter Meeting February 2, 2005

10 Strategic Steps to Reducing Your Energy Costs AEE Regional Chapter Meeting February 2, 2005 10 Strategic Steps to Reducing Your Energy Costs AEE Regional Chapter Meeting February 2, 2005 Presented by: Gary A. Swanson, PE President Energy Management Solutions (612) 819-7975 10 Step Summary 1.

More information

Alcatel-Lucent Modular Cooling Solution

Alcatel-Lucent Modular Cooling Solution T E C H N O L O G Y W H I T E P A P E R Alcatel-Lucent Modular Cooling Solution Redundancy test results for pumped, two-phase modular cooling system Current heat exchange methods for cooling data centers

More information

HEATING, VENTILATION & AIR CONDITIONING

HEATING, VENTILATION & AIR CONDITIONING HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory

More information

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling Joshua Grimshaw Director of Engineering, Nova Corporation

More information

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES

More information

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs

More information

European Code of Conduct for Data Centre. Presentation of the Awards 2013

European Code of Conduct for Data Centre. Presentation of the Awards 2013 European Code of Conduct for Data Centre Presentation of the Awards 2013 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results Started

More information

ENERGY MANAGEMENT. for INDUSTRY AND BUSINESS

ENERGY MANAGEMENT. for INDUSTRY AND BUSINESS ENERGY MANAGEMENT for INDUSTRY AND BUSINESS [Principles of Energy Management] Denis Cooke Denis Cooke & Associates Pty Limited Phone + 61 2 9871 6641 Fax +61 2 9614 1723 Email: denis@decoa.com.au Web Site

More information

Benefits of. Air Flow Management. Data Center

Benefits of. Air Flow Management. Data Center Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded

More information

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Low GWP Replacements for R404A in Commercial Refrigeration Applications Low GWP Replacements for R404A in Commercial Refrigeration Applications Samuel YANA MOTTA, Mark SPATZ Honeywell International, 20 Peabody Street, Buffalo, NY 14210, Samuel.YanaMotta@honeywell.com Abstract

More information

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Energy Efficiency Best Practice Guide Data Centre and IT Facilities 2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

Recovering Stranded Capacity in the Data Center. Greg Bell Driving e-research Across the Pacific `09 Sydney: 11/13/09

Recovering Stranded Capacity in the Data Center. Greg Bell Driving e-research Across the Pacific `09 Sydney: 11/13/09 Recovering Stranded Capacity in the Data Center Greg Bell Driving e-research Across the Pacific `09 Sydney: 11/13/09 2 Recovering Stranded Data Center Capacity most data centers are overcooled & inefficient

More information

AIRAH Presentation April 30 th 2014

AIRAH Presentation April 30 th 2014 Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining

More information

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

More information

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

Server Room Thermal Assessment

Server Room Thermal Assessment PREPARED FOR CUSTOMER Server Room Thermal Assessment Analysis of Server Room COMMERCIAL IN CONFIDENCE MAY 2011 Contents 1 Document Information... 3 2 Executive Summary... 4 2.1 Recommendation Summary...

More information

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Dealing with Thermal Issues in Data Center Universal Aisle Containment Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges

More information

Supermarket Refrigeration Trends in the Asia Pacific Region. Brian Rees Group Technical Manager McAlpine Hussmann Ltd.

Supermarket Refrigeration Trends in the Asia Pacific Region. Brian Rees Group Technical Manager McAlpine Hussmann Ltd. Supermarket Refrigeration Trends in the Asia Pacific Region Brian Rees Group Technical Manager McAlpine Hussmann Ltd. September 2011 View of the world from our place. Asia Pacific 4 Billion people (60%

More information

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment

More information

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the

More information

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends

More information

Typical Air Cooled Data Centre Compared to Iceotope s Liquid Cooled Solution

Typical Air Cooled Data Centre Compared to Iceotope s Liquid Cooled Solution Typical Air Cooled Data Centre Compared to Iceotope s Liquid Cooled Solution White Paper July 2013 Yong Quiang Chi University of Leeds Contents Background of the Work... 3 The Design of the Iceotope Liquid

More information

ALONE. small scale solar cooling device Project No TREN FP7EN 218952. Project No TREN/FP7EN/218952 ALONE. small scale solar cooling device

ALONE. small scale solar cooling device Project No TREN FP7EN 218952. Project No TREN/FP7EN/218952 ALONE. small scale solar cooling device Project No TREN/FP7EN/218952 ALONE small scale solar cooling device Collaborative Project Small or Medium-scale Focused Research Project DELIVERABLE D5.2 Start date of the project: October 2008, Duration:

More information

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance Refrigerant Choices for Commercial Refrigeration Finding the Right Balance 2 CONTENTS 1. Executive Summary 1.1. Introduction 4 1.2. Glossary of terms 5 5. Cases configuration 5.1. Introduction 17 5.2.

More information

Energy savings in commercial refrigeration. Low pressure control

Energy savings in commercial refrigeration. Low pressure control Energy savings in commercial refrigeration equipment : Low pressure control August 2011/White paper by Christophe Borlein AFF and l IIF-IIR member Make the most of your energy Summary Executive summary

More information

Sino-Italian Environment & Energy Building S I E E B

Sino-Italian Environment & Energy Building S I E E B MOST Ministry of Science and Technology Republic of China Sino-Italian Environment & Energy Building S I E E B Concept The Sino-Italy Environment & Energy Building (SIEEB) is an intelligent, ecological

More information

- White Paper - Data Centre Cooling. Best Practice

- White Paper - Data Centre Cooling. Best Practice - White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH

More information

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably Data Center 2020: Delivering high density in the Data Center; efficiently and reliably March 2011 Powered by Data Center 2020: Delivering high density in the Data Center; efficiently and reliably Review:

More information

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the

More information

Office of the Government Chief Information Officer. Green Data Centre Practices

Office of the Government Chief Information Officer. Green Data Centre Practices Office of the Government Chief Information Officer Green Data Centre Practices Version : 2.0 April 2013 The Government of the Hong Kong Special Administrative Region The contents of this document remain

More information

Drives and motors. A guide to using variable-speed drives and motors in data centres

Drives and motors. A guide to using variable-speed drives and motors in data centres Drives motors A guide to using variable-speed drives motors in data centres The power behind the data Private public businesses, from banks to supermarkets, to telecommunications companies internet providers

More information

How To Powertrain A Car With A Hybrid Powertrain

How To Powertrain A Car With A Hybrid Powertrain ELECTRIFICATION OF VEHICLE DRIVE TRAIN THE DIVERSITY OF ENGINEERING CHALLENGES A3PS Conference, Vienna Dr. Frank Beste AVL List GmbH 1 Motivation for Powertrain Electrification Global Megatrends: Urbanization

More information

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

European Code of Conduct for Data Centre. Presentation of the Awards 2012

European Code of Conduct for Data Centre. Presentation of the Awards 2012 European Code of Conduct for Data Centre Presentation of the Awards 2012 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Today Started

More information

UCD School of Agriculture Food Science & Veterinary Medicine Master of Engineering Science in Food Engineering Programme Outline

UCD School of Agriculture Food Science & Veterinary Medicine Master of Engineering Science in Food Engineering Programme Outline Module Details BSEN30010 Bioprocess Principles BSEN30240 Waste Management BSEN40030 Advanced Food Refrigeration Module Description In this module you will be introduced to some of the fundamental theories

More information

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets 2 Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets - Extending Use of New Heat Pump System in Cold Regions

More information

Optimization of combined heating and cooling in Supermarkets

Optimization of combined heating and cooling in Supermarkets Optimization of combined heating and cooling in Supermarkets Funder-Kristensen T. 1 ; Fösel G. 2 and Bjerg P. 3 1 Ph.d. Head of Public & Industry Affairs, Danfoss, Nordborg, 6430, Denmark. 2 Dipl.-Ing.

More information

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling for Simultaneous Heating and Cooling F. Sustainable Energy Centre, University of South Australia Mawson Lakes Boulevard, Mawson Lakes 5095 AUSTRALIA E-mail: Frank.@UniSA.edu.au Abstract The high efficiency

More information

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects Makeup Air For Exhaust Systems In Tight Houses Tony Jellen Engineering Projects PA Housing & Land Development Conference February 23, 2012 Effects of Kitchen Ventilation on Residential Dwellings Anthony

More information

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine G Vicatos J Gryzagoridis S Wang Department of Mechanical Engineering,

More information

Improve competiveness of IDC and enterprise data centers with DCIM

Improve competiveness of IDC and enterprise data centers with DCIM Improve competiveness of IDC and enterprise data centers with DCIM This paper studies the implementation of modern DCIM systems for data centers to improve operational competitiveness with ATEN's DCIM

More information

Smart Campus Management with Cloud Services

Smart Campus Management with Cloud Services UNIVERSITY TRANSILVANIA OF BRAŞOV FACULTY OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE DEPARTMENT OF AUTOMATION, ELECTRONICS AND COMPUTER SCIENCE Sorin-Aurel Moraru, prof.dr.eng. Department Director

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel

More information

Nordic Heat Pump Product Guide

Nordic Heat Pump Product Guide Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps

More information

EU Code of Conduct for Data Centre Efficiency

EU Code of Conduct for Data Centre Efficiency EU Code of Conduct for Data Centre Efficiency A Green Practice Accredited by British Computer Society (BCS) EU Code of Conduct for Data Centre Efficiency Local Organizer Practices in Data Centre Industry

More information

HEATER, AIR CONDITIONING AND VENTILATION

HEATER, AIR CONDITIONING AND VENTILATION 55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

Sea Water Heat Pump Project

Sea Water Heat Pump Project Sea Water Heat Pump Project Alaska SeaLife Center, Seward, AK Presenter: Andy Baker, PE, YourCleanEnergy LLC Also Present is ASLC Operations Manager: Darryl Schaefermeyer ACEP Rural Energy Conference Forum

More information

Postharvest Sample Questions

Postharvest Sample Questions What is the physical principle that allows mechanical refrigeration systems to remove heat from the storage environment? Draw or describe the basic components of a compression refrigeration system (=the

More information

BREEAM Refurbishment and Fit-out 2014 Briefings. Part of the BRE Trust

BREEAM Refurbishment and Fit-out 2014 Briefings. Part of the BRE Trust BREEAM Refurbishment and Fit-out 2014 Briefings Part of the BRE Trust BREEAM for Refurbishment and Fit-out Follows 2 years of development Draft scheme published and consultation from 19 th July 2014 Launched

More information

imagine SOLAR AIR CONDITIONING MADE EASY

imagine SOLAR AIR CONDITIONING MADE EASY imagine SOLAR AIR CONDITIONING MADE EASY WHY SOLAR COOLING? Imagine...being able to fit a solar air conditioning system to your building that would result in dramatic reductions in electricity consumption

More information

VISIT 2010 Fujitsu Forum Europe 0

VISIT 2010 Fujitsu Forum Europe 0 VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00

More information

ArcticStore. product guide environmentally friendly storage solutions

ArcticStore. product guide environmentally friendly storage solutions ArcticStore product guide environmentally friendly storage solutions TITAN Containers founded in 1987 is today one of the premier international suppliers of portable storage solutions. Our domestic rental

More information

Guide to Good Commercial Refrigeration Practice. Part 2. System Design and Component Selection

Guide to Good Commercial Refrigeration Practice. Part 2. System Design and Component Selection Guide to Good Commercial Refrigeration Practice Part 2 System Design and Component Selection Institute of Refrigeration Issue 1 September 2009 CONTENTS 2.0.0 SYSTEM DESIGN AND COMPONENT SELECTION 2.1.0

More information

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling

Energy Efficient Server Room and Data Centre Cooling. Computer Room Evaporative Cooler. EcoCooling Energy Efficient Server Room and Data Centre Cooling Computer Room Evaporative Cooler EcoCooling EcoCooling CREC Computer Room Evaporative Cooler Reduce your cooling costs by over 90% Did you know? An

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

DATA CENTRE DESIGN AND

DATA CENTRE DESIGN AND SPUSC 2008 SOUTH PACIFIC USER SERVICES CONFERENCE DATA CENTRE DESIGN AND ENERGY INITIATIVES Presented by Jarrad Clift Electrical Engineer Greenstar Accredited Presentation Content Data Centres General

More information

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Indirect Adiabatic and Evaporative Data Centre Cooling Solutions by

More information

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power THE EUROPEAN GREEN BUILDING PROGRAMME Technical Module on Combined Heat and Power Contents Foreword...1 1. Introduction...2 2. Inventory of the CHP system...3 3. Assessment of technical energy saving measures...5

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

National Grid Your Partner in Energy Solutions

National Grid Your Partner in Energy Solutions National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National

More information

Speed for SMEs the fastest project in

Speed for SMEs the fastest project in funded by Speed for SMEs the fastest project in Workpackages major steps WP10 creation of a new brand WP 20 working with technical partners and future customers WP 30 the car growes up, IDT re-designed

More information

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis

Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. info@dc-oi.com

More information

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Air-sourced 90 Hot Water Supplying Heat Pump HEM-90A Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A" Takahiro OUE *1, Kazuto OKADA *1 *1 Refrigeration System & Energy Dept., Compressor Div., Machinery Business Kobe Steel has developed an air-sourced

More information

Case study: End-to-end data centre infrastructure management

Case study: End-to-end data centre infrastructure management Case study: End-to-end data centre infrastructure management Situation: A leading public sector organisation suspected that their air conditioning units were not cooling the data centre efficiently. Consequently,

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

DEFROSTING. Service Engineers Section Technical Bulletin No 3

DEFROSTING. Service Engineers Section Technical Bulletin No 3 Service Engineers Section Technical Bulletin No 3 DEFROSTING 1. INTRODUCTION This bulletin is presented to cover the methods used and problems experienced with defrosting of coils for chill and frozen

More information

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How CIBSE ASHRAE Group Data Centre Energy Efficiency: Who, What, Why, When, Where & How Presenters Don Beaty PE, FASHRAE Founder, President & Managing Director DLB Associates Consulting Engineers Paul Finch

More information

Data Center of the Future. Is it possible to be Efficient, Reliable and Cost Effective?

Data Center of the Future. Is it possible to be Efficient, Reliable and Cost Effective? Data Center of the Future Is it possible to be Efficient, Reliable and Cost Effective? Data center challenges: Navigate budget constraints need solutions with a low TCO Avoid downtime need higher availability

More information