Correction of Myopic Astigmatism With Small Incision Lenticule Extraction

Size: px
Start display at page:

Download "Correction of Myopic Astigmatism With Small Incision Lenticule Extraction"

Transcription

1 ORIGINAL ARTICLE Correction of Myopic Astigmatism With Small Incision Lenticule Extraction Anders Ivarsen, MD, PhD; Jesper Hjortdal, MD, DMSc ABSTRACT PURPOSE: To evaluate the outcome after small incision refractive lenticule extraction (SMILE) in patients with myopic astigmatism. METHODS: Seven hundred seventy-five eyes from 403 patients with myopia treated with SMILE for a cylinder of 0.75 diopters (D) or more were identified from patient records. Six hundred sixty-nine eyes were defined as receiving low (< 2.5 D) and 106 eyes as receiving high (> 2.5 D) astigmatic correction. Patients were examined before and 3 months after surgery. SMILE was performed with a Visumax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). Preoperative and postoperative refractions were converted to polar values. Induced torsion and achieved corrections of sphere and cylinder were determined. RESULTS: In low astigmatism, the mean preoperative spherical equivalent (SE) was ±1.67 D and the cylinder was ± 0.49 D. Three months after surgery, SE was ± 0.48 D from target, astigmatism was 0.17 ± 0.42 D undercorrected, and a small but significant torsion of the cylinder axis corresponding to 0.05 ± 0.37 D was found. The astigmatic undercorrection measured 13% per diopter of attempted correction. In high astigmatism, preoperative SE was ± 2.56 D and cylinder was ± 0.67 D. After surgery, the average astigmatic undercorrection was 0.59 ± 0.65 D, equivalent to 16% per diopter of attempted correction. No undercorrection in SE occurred and no torsion was found. CONCLUSIONS: SMILE in myopic astigmatism offers predictable correction of SE, but a small, significant undercorrection of the astigmatic error. The undercorrection increases with the attempted treatment. Only very little rotation of the cylinder axis was found. [J Refract Surg. 2014;30(4): ] I n small incision refractive lenticule extraction (SMILE), a refractive lenticule is created within the corneal stroma and subsequently extracted through a small peripheral incision. 1,2 Currently, the procedure allows correction of myopia and myopic astigmatism. In previous studies, the outcome of SMILE has been found to be on par with femtosecond laser-assisted LASIK (FS-LASIK) for myopia, 3-5 and we recently reported the safety of the treatment to be high. 6 In keratorefractive surgery, correction of astigmatism is generally more difficult than correction of simple spherical errors. 7-9 To date, no studies have systematically evaluated the outcome of astigmatic corrections with SMILE. However, in a study of the flap-based femtosecond lenticule extraction (a previous evolutionary step of SMILE), a 10% undercorrection of the attempted astigmatic correction was found in eyes with mostly low degrees of astigmatism. 10 The current study evaluated the outcome of SMILE in patients with low to high degrees of myopic astigmatism. PATIENTS AND METHODS Since January 2011, SMILE has been routinely performed at the Department of Ophthalmology, Aarhus University Hospital, Denmark. By March 2013, more than 1,800 myopic eyes had been treated. All eyes with an attempted cylinder correction of 0.75 diopters (D) or more were identified from the electronic patient records. Patients were divided into two groups: a low astigmatic group with attempted cylinder correction from 0.75 to 2.25 D and a high astigmatic group with an attempted cylinder correction of 2.50 D or more. Patients From the Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. Submitted: December 5, 2013; Accepted: January 2, 2014; Posted online: April 4, 2014 The authors thank Nicolaj Aagaard, Jens Christian Hedegaard, Henrik Sejersen, and Christina Møller for invaluable aid with clinical controls. The authors have no financial or proprietary interest in the materials presented herein. Correspondence: Anders Ivarsen, MD, PhD, Department of Ophthalmology, Aarhus University Hospital, Noerrebrogade 44, DK-8000 Aarhus C, Denmark. ai@dadlnet.dk doi: / x Copyright SLACK Incorporated

2 TABLE 1 Patient Demographics and Preoperative and Postoperative Refraction by Group a Parameter Low Astigmatism (669 Eyes) High Astigmatism (106 Eyes) Age (y) 39 ± 8 (19 to 56) 36 ± 9 (21 to 54) Gender (M/F) 131/213 23/36 Preoperative sphere (D) ± 1.69 ( to 0) ± 2.66 (-9.50 to -0.25) Preoperative cylinder (D) ± 0.49 (-2.75 to 0) ± 0.67 (-5.75 to -2.50) 3-month postoperative sphere (D) ± 0.53 (-3.25 to 2.25) 0.25 ± 0.61 (-1.50 to 2.25) 3-month postoperative cylinder (D) ± 0.36 (-1.75 to 0) ± 0.58 (-2.75 to 0) D = diopters a Data are given as mean ± standard deviation with range in parenthesis. were examined before and 3 months after surgery. Examinations included manifest refraction and uncorrected (UDVA) and corrected distance visual acuity (CDVA). In a few cases, postoperative anterior segment optical coherence tomography (Heidelberg Spectralis; Heidelberg Engineering GmbH, Heidelberg, Germany) was performed to visualize the intrastromal interface. Specially trained optometrists performed all clinical refractions. Journal of Refractive Surgery Vol. 30, No. 4, 2014 Surgery In all patients, surgery was performed using topical anesthesia with two drops of 0.8% oxybuprocain tetrachloride a few minutes before surgery. SMILE was performed using a 500-kHz Visumax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) as previously detailed. 3,4 The patient was asked to fixate the blinking target, the eye was centered under the laser, and suction was applied. The posterior surface of the lenticule was cut initially, followed by the anterior surface that was extended toward the periphery to allow surgical manipulation of the lenticule. A 30 - to 60 -incision was created at the 12-o clock position. The diameter of the lenticule ranged from 6.0 to 7.0 mm with a transition zone of 0.0 or 0.1 mm. The diameter of the cap ranged from 7.3 to 7.7 mm and the cap thickness varied from 110 to 130 µm. All surgeries were performed with one of two different laser settings: setting 1 with a laser cut energy index of 25 to 27 (approximately 130 nj) and a spot spacing of 2.5 to 3.0 µm, or setting 2 with a laser cut energy index of 34 (approximately 170 nj) and a spot spacing of 4.5 µm. Laser setting 1 was used for surgery in 244 low astigmatic and 28 high astigmatic eyes, whereas setting 2 was used in the remaining 425 low and 78 high astigmatic procedures. A blunt spatula was used to break any tissue bridges after the laser treatment and the lenticule was removed with a pair of forceps. Postoperative treatment comprised chloramphenicol (Takeda Pharma, Roskilde, Denmark) and fluorometholone (Flurolon; Allergan, Upplands Väsby, Sweden) four times a day tapered over 2 weeks. Analyses All preoperative and postoperative spherocylindrical refractions were converted into spherical equivalent (SE) and two polar values as previously reported. 11,12 In brief, to fully characterize the refractive cylinders, we calculated the astigmatic polar values at the main meridian (AKP) and at an oblique meridian 45 counterclockwise to the main meridian (AKP +45 ). Surgically induced astigmatism was determined from the change in AKP from before to after surgery (DAKP), and surgically induced torsion or rotation of the cylinder axis was determined from the change in AKP +45 (DAKP +45 ), with negative values indicating a clockwise change. The errors in treatment, AKP error and AKP +45,error, were calculated by subtraction of the achieved change from the intended value. The average polar values were converted to net cylinder format as previously shown and the blur due to the postoperative refraction (error of treatment) was estimated by calculation of the amount of defocus as previously reported. 12 Data were tested for normality using the D Agostino Pearson test. Statistics were performed as unpaired t tests, and as a bivariate analysis of the combined mean polar values with calculation of two-dimensional confidence ellipses and determination of Hotelling s T 2 as previously detailed. 11,13 RESULTS A total of 775 eyes with an attempted astigmatic correction of 0.75 D or more were identified. Of these eyes, 669 were treated for astigmatism below 2.50 D, and the remaining 106 eyes were treated for astigmatism of 2.50 D or more. The preoperative and postoperative patient characteristics are given in Table

3 Figure 1. Achieved versus intended spherical equivalent correction in low astigmatism (A) and high astigmatism (B). Points above and below the dashed lines indicate over- and undercorrection, respectively. The solid lines indicate the outcome of the linear regression analyses. Figure 2. Error in spherical equivalent refraction given as the percentage of eyes obtaining the specified refraction. Low Astigmatism Three months after surgery, the intended and achieved spherical equivalent corrections were highly correlated (R 2 = 0.93; P <.001) (Figure 1A) with 77% and 95% of the eyes within ±0.50 and ±1.00 D of the intended correction, respectively (Figure 2). In Table 2, the polar values of the low astigmatic group are detailed. After surgery, the mean reduction in spherical equivalent power was 7.26 ± 1.57 D, and the mean induced surgical flattening at the main meridian was 1.04 ± 0.57 D. However, a significant undercorrection in both spherical power and astigmatic polar value (AKP) was observed. Furthermore, the observed change in astigmatic power at the oblique meridian indicated that a small but significant counterclockwise torsion of the cylinder axis had occurred (DAKP +45 ). When examining right and left eyes separately, the DAKP +45 averaged ± 0.35 D in right eyes, and 0.12 ± 0.34 D in left eyes, indicating no torsion in right eyes, but a small significant counterclockwise torsion in left eyes (P <.001). The intended and achieved astigmatic corrections were significantly correlated (R 2 = 0.50, P <.001), but linear regression showed an average undercorrection of 13% per diopter of attempted correction (Figure 3A). As seen in Figures 3B-4A, the error in astigmatic correction (AKP error ) showed no correlation to the intended spherical correction (R 2 = ns) or the intended astigmatic correction (R 2 = 0.03; P = <.001). Figure 5A shows the bivariate analysis of the polar values. Confidence ellipses are given for individual samples and for the combined mean, and demonstrate a significant combined error of treatment (Hotelling s T 2 = 108; P <.001). The astigmatic error, given in conventional net cylinder format, was 0.17 D at 8 relative to the preoperative stronger meridian, and the mean defocus after surgery was 0.48 ± 0.35 D. A total of 602 eyes were treated for plano refraction (± 0.25 D), and 487 of these eyes (81%) had a UDVA of 20/25 or better (Figure 6A). By 3 months, 19 eyes had lost two or more lines in CDVA (Figure 6B); however, these patients were offered a late reexamination, and all eyes recovered to within one line of the preoperative CDVA. High Astigmatism In highly astigmatic eyes, the intended and achieved spherical equivalent corrections 3 months after surgery were strongly correlated (R 2 = 0.97; P <.001) 242 Copyright SLACK Incorporated

4 TABLE 2 Mean ± SD Polar Values (D) in Eyes With High and Low Astigmatism Parameter Preoperative Postoperative Target Error of treatment High astigmatism SE power ± ± ± ± 0.48 a AKP 1.22 ± ± ± ± 0.42 a AKP ± ± ± 0.37 b Low astisgmatism SE power ± ± ± ± 0.49 AKP 3.22 ± ± ± ± 0.65 a,c AKP ± ± ± 0.47 SD = standard deviation; D = diopters; SE = spherical equivalent; AKP = astigmatic polar value, or the astigmatic power, at the main meridian; AKP +45 = astigmatic power at the reference meridian, 45 counterclockwise from the main meridian. a Significant undercorrection (paired t test, P <.001). b Significant torsion (paired t test, P <.001). c Significant difference from low astigmatic eyes (unpaired t-test; P <.001). Figure 3. (A) Achieved versus intended astigmatic correction for eyes with low (open circles) and high astigmatism. In the high astigmatic eyes, crosses indicate eyes treated with laser setting 1 and closed circles indicate eyes treated with laser setting 2. Points above and below the dashed lines indicate over- and undercorrection, respectively. (B) Error in astigmatic correction at the main meridian (AKP error ) as a function of the intended astigmatic correction for eyes with low (open circles) and high (closed circles) astigmatism. Figure 4. Error in astigmatic correction at the main meridian (AKP error ) as a function of the intended spherical correction for (A) low and (B) high astigmatic eyes. Journal of Refractive Surgery Vol. 30, No. 4,

5 Figure 5. Bivariate representation of the error of treatment in (A) low and (B) high astigmatic eyes. AKP error indicates the error of treatment at the main meridian (positive values representing the amount of undercorrection). DAKP +45 indicates the induced astigmatism at a 45 oblique meridian; representing the amount of torsion or rotation of the cylinder axis. Confidence ellipses comprising 95% of the observations are given for individual samples (dashed red) and for the combined mean (solid green); the ellipses being equivalent to the standard variation, respectively the standard error of mean in a univariate analysis. The dimensions of the confidence ellipses indicate the relative inaccuracy of the treatments. The statistical significance may be read directly from the figure, with the combined mean errors being significantly different from zero, as the origin is not included in the confidence ellipses (solid green). All values are given in diopters. Figure 6. (A) Cumulative percentage of eyes obtaining the specified uncorrected distance visual acuity in Snellen lines. The figure includes only eyes treated for plano refraction. (B) Percentage of eyes with the specified loss or gain in corrected distance visual acuity 3 months after surgery. (Figure 1B). A total of 77% of the eyes were within ±0.5 D of the intended correction and 97% were within ±1.0 D (Figure 2). Table 2 shows the polar values of the high astigmatic eyes. The average reduction in spherical equivalent power was 5.76 ± 2.45 D, and the surgically induced flattening at the main meridian averaged 2.61 ± 0.76 D. A significant undercorrection in AKP was observed. However, in high astigmatic eyes no significant change at the oblique meridian was found (DAKP +45 ), indicating that no torsion of the cylinder axis had been induced. Similarly, there were no significant differences in DAKP +45 between right and left eyes. Comparing the low and high astigmatic groups, significantly more undercorrection was seen after operation for high astigmatism, whereas no difference was observed with respect to the error in spherical correction or induced torsion (Table 2). The intended and achieved astigmatic corrections were weakly correlated (R 2 = 0.38, P <.001), with an average undercorrection of 19% per diopter of attempted correction (Figure 3A). Of the 20 eyes with an astigmatic undercorrection of more than 1.00 D, significantly more eyes had been treated with laser setting 244 Copyright SLACK Incorporated

6 1 (11 of 28 eyes) than with laser setting 2 (9 of 78 eyes) (chi-square test; P <.001), and when considering only eyes treated with laser setting 2, the average undercorrection in high astigmatic eyes was reduced to 16% per diopter of attempted correction. In high astigmatic eyes, the error in astigmatic correction (AKP error ) showed only a weak correlation to the intended spherical correction (R 2 = 0.05; P =.03) (Figure 4B) or to the intended astigmatic correction (R 2 = 0.12; P <.001) (Figure 3B). Considering all eyes (both low and high cylinders), the correlation between AKP error and the intended astigmatic correction was still weak (R 2 = 0.13; P <.001). The bivariate analysis of the polar values is given in Figure 5B for eyes with high astigmatism. The confidence ellipse for the combined means showed a significant combined error of treatment (Hotelling s T 2 = 43; P <.001). The astigmatic error, given in conventional net cylinder format, was 0.59 D at 1 relative to the preoperative stronger meridian, and the mean defocus after surgery was 0.60 ± 0.36 D. In the high astigmatic group, 91 eyes were treated for plano refraction (± 0.25 D), and 58 of these eyes (64%) had a UDVA of 20/25 or better (Figure 6A). By 3 months, 1 eye had lost two or more lines of CDVA (Figure 6B). In Figure 7, an optical coherence tomography image of the changes 3 months after SMILE for high astigmatism is shown. At the main meridian, an abrupt stromal change was observed corresponding to the edge of the removed lenticule. Matching changes in epithelial thickness could be seen in the overlying epithelium (Figure 7A). In contrast, a smooth interface was seen at the 90 orthogonal meridian (Figure 7B). DISCUSSION The current study demonstrates that SMILE offers precise and safe correction of low to high degrees of myopic astigmatism. Overall, the correction of spherical equivalent power was very precise, although eyes with low cylinders showed a slight undercorrection in contrast to high astigmatic eyes. With respect to the cylinder correction, a significant undercorrection of astigmatism was observed and the error of treatment increased with higher attempted astigmatic correction. On average, the undercorrection was 13% per diopter of attempted cylinder correction in low astigmatic and 16% per diopter in highly astigmatic eyes. In a recent study, we evaluated the outcome of FS-LASIK for high astigmatism in myopic eyes using the Carl Zeiss Meditec MEL-80 excimer laser. 9 The patients in this previous study were recruited from the same population as those in the current study and showed Journal of Refractive Surgery Vol. 30, No. 4, 2014 Figure 7. Anterior segment optical coherence tomography at the lenticule edge 3 months after a 3.5 diopters astigmatic correction with SMILE. (A) Image taken at the main meridian. An abrupt stromal change is observed at the edge of the removed lenticule (arrow). The slightly sloped edge is most likely due to the 0.1-mm transition zone. The overlying epithelium shows matching changes (arrowheads) with thin epithelium at the edge (1) and an increased thickness more centrally (2). (B) Image taken 90 orthogonal to the main meridian. The interface is seen as smooth with no abrupt changes. similar preoperative characteristics. After FS-LASIK, we found an error in AKP error of 0.77 ± 0.62 D, which was close to our current observations of 0.59 ± 0.65 D after SMILE. However, in FS-LASIK, an undercorrection of 21% per diopter of attempted cylinder correction in highly astigmatic eyes was found, which was somewhat higher than in the current study. In contrast, the U.S. Food and Drug Administration approval studies for the MEL-80 excimer laser 14 found a correction ratio (induced/intended astigmatic correction) of up to 1.42 in eyes with low astigmatism, indicating considerable overcorrection. Similarly, the U.S. Food and Drug Administration approval of the Wavelight Allegretto 15 reported a correction ratio of 1.16, again indicating overcorrection of the astigmatic correction after LASIK in predominantly low astigmatic eyes. From a clinical point of view, however, slight undercorrection would be preferred to overcorrection because a change in the direction of the cylinder axis probably is poorly accepted by patients. No other studies on SMILE have performed a rigorous evaluation of astigmatic corrections. However, one study evaluated the outcome for up to 6 months after 200-kHz femtosecond lenticule extraction in myopic 245

7 eyes with primarily lower degrees of astigmatism. 10 An undercorrection of approximately 10% was reported, which was similar to the observations in this study. Furthermore, the authors found no indication of rotation of the cylinder axis. The current study demonstrated a minor induced torsion in left eyes corrected for low astigmatism. However, induced torsion would be expected to be more prominent in highly astigmatic eyes, and to be independent of side because the surgical approach is identical for left and right eyes. Thus, the observed torsion by 3 months is most likely a chance finding. Furthermore, the torsion was small and of little clinical significance, as shown by the net cylinder values of 0.17 D at 8 and 0.59 D at 1 in low and high astigmatic eyes, respectively. In SMILE, decentration of the lenticule may contribute to postoperative astigmatism and coma. In this study, induced higher-order aberrations and decentration of the lenticule were not evaluated. However, in a previous study, the average decentration after SMILE was found to be small. 4 In other studies, femtosecond lenticule extraction and FS-LASIK have been demonstrated to induce similar amounts of coma. 16 Furthermore, astigmatism induced by decentration would most likely influence the main cylinder axis, and in the current study the observed torsion was small, which is why it seems unlikely that decentration had any major impact on the postoperative cylinder. Nevertheless, docking of the eye in the SMILE procedure may be more challenging in highly astigmatic eyes, and it would be of interest to evaluate the induction of higher-order aberrations in a future study. Interestingly, we found the laser settings to influence the outcome after SMILE in highly astigmatic eyes. Thus, the initial laser setting (with low energy and close spot spacing) had significantly more eyes with an undercorrection of at least 1 D than the laser setting with higher energy and larger spot spacing. A similar pattern could not be observed in eyes corrected for low astigmatism. Why laser settings should have an impact on the precision of the astigmatic correction is not obvious because the shape of the lenticule should be identical. However, we recently reported that visual recovery is slower after setting 1 than setting 2. 6 Similarly, other studies have reported that the laser scanning trajectory and energy levels influence the postoperative outcome. 17,18 Whether additional adjustments in the laser parameters can further improve the astigmatic corrections remain to be elucidated. In this study, patients were only evaluated after 3 months. However, the refraction may change during the first months after surgery; probably more so after astigmatic corrections than after pure spherical corrections. Regression after refractive surgery including photorefractive keratectomy and LASIK may occur due to an increase in epithelial thickness after myopic refractive surgery 19 or due to wound repair with deposition of new stromal tissue. 19,20 In SMILE, the wound repair has been demonstrated to be limited, 21 but an increase in central epithelial thickness has been noted. 22 Most studies have reported little to no regression after SMILE 2,3 ; yet, epithelial hyperplasia could influence the postoperative refraction and contribute to the observed astigmatic undercorrection in this study. In contrast to excimer laser treatments, the peripheral transition zone in SMILE is small. Whereas this probably has little consequence in myopia where the lenticule becomes thinner toward the edge, it could be significant in high astigmatic corrections where the lenticule edge in the main meridian may become very steep. Because abrupt changes in corneal thickness are usually mitigated by compensatory epithelial hyperplasia, this could contribute to undercorrection or postoperative regression of the obtained refractive change at the specific meridian. In optical coherence tomography images, we found a rather prominent stromal change corresponding to the lenticule edge with matching changes in epithelial thickness. In previous studies of keratorefractive procedures, changes in epithelial thickness have been demonstrated to occur within the first few weeks after surgery. 19 Unfortunately, the temporal changes could not be evaluated in the current study, and it remains to be determined if the changes in epithelial thickness at the main meridian contributes to the observed astigmatic undercorrection and may change further with increasing time after surgery. In this study, a loss of two or more lines in CDVA was found in 2.8% of low astigmatic eyes and 0.9% of high astigmatic eyes 3 months after surgery. In comparison to LASIK this is a relatively high loss in CDVA. 23 However, patients with a significant visual loss were seen at an extended follow-up, where all eyes were found to have returned to within one line of their preoperative CDVA. Furthermore, in a recent study we evaluated the complications and safety of the first 1,574 eyes treated with SMILE at our department and found late recovery of CDVA in all 24 eyes with a significant loss by 3 months. 6 Patients with low astigmatism generally fared better with respect to UDVA than patients with high cylinders. This was to be expected due to less residual astigmatism in the low astigmatic eyes, although the spherical equivalent refraction was slightly less precise. The observed difference in UDVA between low and high astigmatic eyes matched the average defocus value that was marginally better in low astigmatism. 246 Copyright SLACK Incorporated

8 The current study demonstrates that predictable and safe correction of myopic astigmatism can be performed with SMILE. However, a small but significant undercorrection was found, in particular for high degrees of astigmatism. In contrast, minimal torsion was induced by the treatment. Overall, the results were on par with previous evaluations of FS-LASIK and femtosecond lenticule extraction. AUTHOR CONTRIBUTIONS Study concept and design (AI, JH); analysis and interpretation of data (AI); writing the manuscript (AI); critical revision of the manuscript (JH); administrative, technical, or material support (JH) REFERENCES 1. Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: all-in-one femtosecond laser refractive surgery. J Cataract Refract Surg. 2011;37: Sekundo W, Kunert KS, Blum M. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study. Br J Ophthalmol. 2011;95: Vestergaard A, Ivarsen AR, Asp S, Hjortdal JØ. Small-incision lenticule extraction for moderate to high myopia: predictability, safety, and patient satisfaction. J Cataract Refract Surg. 2012;38: Hjortdal JØ, Vestergaard AH, Ivarsen A, Ragunathan S, Asp S. Predictors for the outcome of small-incision lenticule extraction for myopia. J Refract Surg. 2012;28: Zhao J, Yao P, Li M, et al. The morphology of corneal cap and its relation to refractive outcomes in femtosecond laser small incision lenticule extraction (SMILE) with anterior segment optical coherence tomography observation. PLoS One. 2013;8:e Ivarsen A, Asp S, Hjortdal, J. Safety and complications of more than 1500 small-incision lenticule extraction procedures (published online ahead of print December 20, 2013). doi: /j. ophtha Ophthalmology. 7. Abolhassani A, Shojaei A, Baradaran-Rafiee AR, Eslani M, Elahi B, Noorizadeh F. Vector analysis of cross cylinder LASIK with the NIDEK EC-5000 excimer laser for high astigmatism. J Refract Surg. 2009;25: Sugar A, Rapuano CJ, Culbertson WW, et al. Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy: a report by the American Academy of Ophthalmology. Ophthalmology. 2002;109: Ivarsen A, Næser K, Hjortdal J. Laser in situ keratomileusis for high astigmatism in myopic and hyperopic eyes. J Cataract Refract Surg. 2013;39: Kunert KS, Russmann C, Blum M, Sluyterman V L G. Vector analysis of myopic astigmatism corrected by femtosecond refractive lenticule extraction. J Cataract Refract Surg. 2013;39: Næser K, Hjortdal J. Polar value analysis of refractive data. J Cataract Refract Surg. 2001;27: Næser K. Assessment and statistics of surgically induced astigmatism. Acta Ophthalmol. 2008;86: Næser K, Hjortdal J. Multivariate analysis of refractive data: mathematics and statistics of spherocylinders. J Cataract Refract Surg. 2001;27: U.S. Food and Drug Administration. Medical Devices. Carl Zeiss Meditec MEL 80 Excimer Laser System - P Available at: P060004b.pdf. Accessed October 11, U.S. Food and Drug Administration. Medical Devices. Wave- Light ALLEGRETTO WAVE Excimer Laser System - P Available at: P020050b.pdf. Accessed October 11, Vestergaard A, Ivarsen A, Asp S, Hjortdal JØ. Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx flex and comparison with a retrospective study of FS-laser in situ keratomileusis. Acta Ophthalmol. 2013;91: Shah R, Shah S. Effect of scanning patterns on the results of femtosecond laser lenticule extraction refractive surgery. J Cataract Refract Surg. 2011;37: Riau AK, Ang HP, Lwin NC, Chaurasia SS, Tan DT, Mehta JS. Comparison of four different VisuMax circle patterns for flap creation after small incision lenticule extraction. J Refract Surg. 2013;29: Ivarsen A, Fledelius W, Hjortdal JØ. Three-year changes in epithelial and stromal thickness after PRK or LASIK for high myopia. Invest Ophthalmol Vis Sci. 2009;50: Moller-Pedersen T, Cavanagh HD, Petroll WM, Jester JV. Stromal wound healing explains refractive instability and haze development after photorefractive keratectomy: a 1-year confocal microscopic study. Ophthalmology. 2000;107: Riau AK, Angunawela RI, Chaurasia SS, Lee WS, Tan DT, Mehta JS. Early corneal wound healing and inflammatory responses after refractive lenticule extraction (ReLEx). Invest Ophthalmol Vis Sci. 2011;52: Vestergaard AH, Grauslund J, Ivarsen AR, Hjordal JØ. Central corneal sublayer pachymetry and biomechanical properties after refractive femtosecond laser lenticule extraction. J Refract Surg. 2014;30: Farjo AA, Sugar A, Schallhorn SC, et al. Femtosecond lasers for LASIK flap creation: a report by the American Academy of Ophthalmology. Ophthalmology. 2013;120:e5-e20. Journal of Refractive Surgery Vol. 30, No. 4,

Anterior Segment Cornea/External Disorders

Anterior Segment Cornea/External Disorders Anterior Segment Cornea/External Disorders New Developments in the Lenticule Extraction Procedure Jesper Hjortdal 1 and Anders Ivarsen 2 1. Clinical Professor; 2. Assistant Professor, Department of Ophthalmology,

More information

Power Vascular Analysis of Anterior and Postoperative Corneal After Refractive Lasers

Power Vascular Analysis of Anterior and Postoperative Corneal After Refractive Lasers Ophthalmology Volume 015, Article ID 915853, 6 pages http://dx.doi.org/10.1155/015/915853 Clinical Study Anterior and Posterior Corneal Astigmatism after Refractive Lenticule Extraction for Myopic Astigmatism

More information

FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US

FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US JON DISHLER, MD DENVER, COLORADO, USA INTRODUCTION AND STUDY OBJECTIVES This article summarizes the first US

More information

For approximately two decades photorefractive keratectomy. Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK.

For approximately two decades photorefractive keratectomy. Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK. Cornea Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK Anders Ivarsen and Jesper Hjortdal PURPOSE. To examine long-term changes in corneal power and aberrations in myopic patients

More information

In 2001, femtosecond (FS) laser technology was introduced

In 2001, femtosecond (FS) laser technology was introduced CLINICAL SCIENCE Clinical Outcomes After SMILE and Femtosecond Laser-Assisted LASIK for Myopia and Myopic Astigmatism: A Prospective Randomized Comparative Study Manli Liu, PhD, Yile Chen, PhD, Danyang

More information

Comparing Femtosecond Lenticule Extraction (FLEx) and Femtosecond Laser In-situ Keratomileusis (LASIK) for Myopia and Astigmatism

Comparing Femtosecond Lenticule Extraction (FLEx) and Femtosecond Laser In-situ Keratomileusis (LASIK) for Myopia and Astigmatism Original Article Philippine Journal of OPHTHALMOLOGY Comparing Femtosecond Lenticule Extraction (FLEx) and Femtosecond Laser In-situ Keratomileusis (LASIK) for Myopia and Astigmatism Tina Marie Saban-Roa,

More information

Richard S. Hoffman, MD. Clinical Associate Professor of Ophthalmology Oregon Health & Science University

Richard S. Hoffman, MD. Clinical Associate Professor of Ophthalmology Oregon Health & Science University Zeiss Mel 80 and Visumax Refractive Laser Systems Richard S. Hoffman, MD Clinical Associate Professor of Ophthalmology Oregon Health & Science University No Financial Interest ZEISS Workstation CRS-Master

More information

Retreatment by Lifting the Original Laser in Situ Keratomileusis Flap after Eleven Years

Retreatment by Lifting the Original Laser in Situ Keratomileusis Flap after Eleven Years Retreatment by Lifting the Original Laser in Situ Keratomileusis Flap after Eleven Years Hassan Hashemi, MD 1,2 Mehrdad Mohammadpour, MD 3 Abstract Purpose: To describe a case of successful laser in situ

More information

RELEX SMILE AND SMILE EXTRA.. OUR 1 YEAR RESULTS AND PATIENTS SURVEY

RELEX SMILE AND SMILE EXTRA.. OUR 1 YEAR RESULTS AND PATIENTS SURVEY RELEX SMILE AND SMILE EXTRA.. OUR 1 YEAR RESULTS AND PATIENTS SURVEY DR SANDIP MITRA MD FRCS CORNEA AND REFRACTIVE FELLOW (ROYAL VICTORIA EYE AND EAR HOSPITAL, AUSTRALIA) RELEX SMILE UNIT AT THE ALZAHRA

More information

Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction

Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction Zhao et al. BMC Ophthalmology 2014, 14:68 CASE REPORT Open Access Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction Jing Zhao, Peijun Yao, Zhi Chen, Meiyan

More information

Life Science Journal 2014;11(9) http://www.lifesciencesite.com. Cross cylinder Challenging cases and their resultswith Nidek Quest (EC-5000)

Life Science Journal 2014;11(9) http://www.lifesciencesite.com. Cross cylinder Challenging cases and their resultswith Nidek Quest (EC-5000) Cross cylinder Challenging cases and their resultswith Nidek Quest (EC-5000) Gamal Mostafa Abo El Maaty, Mohamed Elmoddather, Mahmoud Ibrahem Ghazy, Mohamed Al-Taher Ophthalmology Department, Faculty of

More information

Comparative Study of Visual Outcome between Femtosecond Lasik with Excimer Laser and All Femtosecond Relex Small Incision Lenticule Extraction (Smile)

Comparative Study of Visual Outcome between Femtosecond Lasik with Excimer Laser and All Femtosecond Relex Small Incision Lenticule Extraction (Smile) IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-853, p-issn: 2279-861.Volume 14, Issue 11 Ver. IX (Nov. 215), PP 44-53 www.iosrjournals.org Comparative Study of Visual Outcome between

More information

Anterior Elevation Maps as the Screening Test for the Ablation Power of Previous Myopic Refractive Surgery

Anterior Elevation Maps as the Screening Test for the Ablation Power of Previous Myopic Refractive Surgery Anterior Elevation Maps as the Screening Test for the Ablation Power of Previous Myopic Refractive Surgery Soo Yong Jeong, MD, Hee-Seung Chin, MD, PhD, Jung Hyub Oh, MD, PhD Department of Ophthalmology,

More information

Comparison of Residual Stromal Bed Thickness and Flap Thickness at LASIK and Post-LASIK Enhancement in Femtosecond Laser-Created Flaps

Comparison of Residual Stromal Bed Thickness and Flap Thickness at LASIK and Post-LASIK Enhancement in Femtosecond Laser-Created Flaps Comparison of Residual Stromal Bed Thickness and Flap Thickness at LASIK and Post-LASIK Enhancement in Femtosecond Laser-Created Flaps Lingo Y. Lai, MD William G. Zeh, MD Clark L. Springs, MD The authors

More information

Preliminary U.S. FDA Outcomes of SMILE

Preliminary U.S. FDA Outcomes of SMILE Preliminary U.S. FDA Outcomes of SMILE D. REX HAMILTON, MD, MS, FACS HEALTH SCIENCES CLINICAL PROFESSOR OF OPHTHALMOLOGY MEDICAL DIRECTOR, UCLA LASER REFRACTIVE CENTER STEIN EYE INSTITUTE, GEFFEN SCHOOL

More information

Efficacy, safety, predictability, aberrations and corneal. corneal biomechnical parameters after SMILE and FLEx: Metaanalysis.

Efficacy, safety, predictability, aberrations and corneal. corneal biomechnical parameters after SMILE and FLEx: Metaanalysis. 陨 灶 贼 允 韵 责 澡 贼 澡 葬 造 皂 燥 造 熏 灾 燥 造 援 9 熏 晕 燥 援 5 熏 May 18, 圆 园 16 www. ijo. cn 栽 藻 造 押 8629 原 愿 圆 圆 源 缘 员 苑 圆 8629-82210956 耘 皂 葬 蚤 造 押 ijopress 岳 员 远 猿 援 糟 燥 皂 窑 Meta-Analysis 窑 Efficacy, safety, predictability,

More information

Vector analysis of low to moderate astigmatism with small incision lenticule extraction (SMILE): results of a 1-year follow-up

Vector analysis of low to moderate astigmatism with small incision lenticule extraction (SMILE): results of a 1-year follow-up Zhang et al. BMC Ophthalmology 2015, 15:8 RESEARCH ARTICLE Open Access Vector analysis of low to moderate astigmatism with small incision lenticule extraction (SMILE): results of a 1-year follow-up Jiamei

More information

Wavefront technology has been used in our

Wavefront technology has been used in our Wavefront Customized Ablations With the WASCA Asclepion Workstation Sophia I. Panagopoulou, BSc; Ioannis G. Pallikaris, MD ABSTRACT PURPOSE: WASCA (Wavefront Aberration Supported Cornea Ablation) is a

More information

Flapless. All-femto. Single-step.

Flapless. All-femto. Single-step. Supplement to October 2012 ReLEx smile Flapless. All-femto. Single-step. Laser vision correction beyond LASIK. ReLEx smile Flapless. All-femto. Single-step. CONTENTS 3 Biomechanical Advantages of ReLEx

More information

OCT-guided Femtosecond Laser for LASIK and Presbyopia Treatment

OCT-guided Femtosecond Laser for LASIK and Presbyopia Treatment Shinagawa LASIK Center OCT-guided Femtosecond Laser for LASIK and Presbyopia Treatment Minoru Tomita, MD, Ph.D 1) Executive Medical Director at Shinagawa LASIK Center, Tokyo, Japan 2) Clinical Professor

More information

LASIK VS. SMILE CLINICAL REVIEW AND REPORT FOR EYE CARE PROFESSIONALS

LASIK VS. SMILE CLINICAL REVIEW AND REPORT FOR EYE CARE PROFESSIONALS LASIK VS. SMILE CLINICAL REVIEW AND REPORT FOR EYE CARE PROFESSIONALS 968) was one of almologists who staff position at oronto because rt anti-semitism. series of events impact on the nto. Determined possible

More information

Alain Saad, MD, Alice Grise-Dulac, MD, Damien Gatinel, MD, PhD

Alain Saad, MD, Alice Grise-Dulac, MD, Damien Gatinel, MD, PhD CASE REPORT Bilateral loss in the quality of vision associated with anterior corneal protrusion after hyperopic LASIK followed by intrastromal femtolaser-assisted incisions Alain Saad, MD, Alice Grise-Dulac,

More information

Femtosecond Lasers in LASIK Surgery

Femtosecond Lasers in LASIK Surgery Femtosecond Lasers in LASIK Surgery Dr Chan Tat Keong Senior Consultant Refractive Surgery Service Singapore National Eye Centre Disclosure Speaker has no financial interest in the products to be discussed

More information

Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens

Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens Donald R. Sanders, MD, PhD; Edwin J. Sarver, PhD ABSTRACT PURPOSE: To demonstrate the methodology

More information

Uniquely Safe. predictably better for our patients. enhancement, may be significantly reduced.

Uniquely Safe. predictably better for our patients. enhancement, may be significantly reduced. Uniquely Safe Clinical Support: Six different studies verify the improved safety of flap creation with the INTRALASE FS laser when compared to traditional microkeratomes. Clinical studies validate the

More information

Despite being a relatively safe and

Despite being a relatively safe and APACRS Asia-Pacific The news magazine of the Asia-Pacific Association of Cataract & Refractive Surgeons Supplement to EyeWorld Asia-Pacific Winter 2015 Shaping the refractive laser landscape Sponsored

More information

Mathematical Model to Compare the Relative Tensile Strength of the Cornea After PRK, LASIK, and Small Incision Lenticule Extraction

Mathematical Model to Compare the Relative Tensile Strength of the Cornea After PRK, LASIK, and Small Incision Lenticule Extraction ORIGINAL ARTICLE Mathematical Model to Compare the Relative Tensile Strength of the Cornea After PRK, LASIK, and Small Incision Lenticule Extraction Dan Z. Reinstein, MD, MA(Cantab), FRCOphth; Timothy

More information

Conductive keratoplasty (CK) utilizes radiofrequency energy. Original Article

Conductive keratoplasty (CK) utilizes radiofrequency energy. Original Article Original Article Comparing the Rate of Regression after Conductive Keratoplasty with or without Prior Laser-Assisted in situ Keratomileusis or Photorefractive Keratectomy Majid Moshirfar, Erik Anderson

More information

Pre-Operative Laser Surgery Information

Pre-Operative Laser Surgery Information Pre-Operative Laser Surgery Information Contact 1800 10 20 20 Our Facility The Canberra Eye Laser Centre has always been at the forefront of refractive technology employing the most up to date equipment

More information

Overview of Refractive Surgery

Overview of Refractive Surgery Overview of Refractive Surgery Michael N. Wiggins, MD Assistant Professor, College of Health Related Professions and College of Medicine, Department of Ophthalmology Jones Eye Institute University of Arkansas

More information

Multi-Centre Evaluation of TransPRK outcomes with SCHWIND AMARIS using SmartPulse Technology

Multi-Centre Evaluation of TransPRK outcomes with SCHWIND AMARIS using SmartPulse Technology study 2015 Multi-Centre Evaluation of TransPRK outcomes with SCHWIND AMARIS using SmartPulse Technology David T. Lin, MD, Canada, Paolo Vinciguerra, MD, Italy, Maria C. Arbelaez, MD, Oman, Shady T. Awwad,

More information

Quality Control in Refractive Surgery

Quality Control in Refractive Surgery Quality Control in Refractive Surgery Stefan Pieger*, M.Sc. Ingenieurbüro Pieger GmbH, Wendelstein, Germany Introduction Personal experience as application specialist for refractive excimer lasers since

More information

The Evolution of the Optical Zone in Corneal Refractive Surgery. Bruce Drum, Ph.D.

The Evolution of the Optical Zone in Corneal Refractive Surgery. Bruce Drum, Ph.D. The Evolution of the Optical Zone in Corneal Refractive Surgery. Bruce Drum, Ph.D. FDA, Division of Ophthalmic and ENT Devices, Rockville, MD Disclaimer This presentation represents the professional opinion

More information

Comparison Combined LASIK Procedure for Ametropic Presbyopes and Planned Dual Interface for Post-LASIK Presbyopes Using Small Aperture Corneal Inlay

Comparison Combined LASIK Procedure for Ametropic Presbyopes and Planned Dual Interface for Post-LASIK Presbyopes Using Small Aperture Corneal Inlay Comparison Combined LASIK Procedure for Ametropic Presbyopes and Planned Dual Interface for Post-LASIK Presbyopes Using Small Aperture Corneal Inlay Minoru Tomita, MD, PhD 1,2 1) Shinagawa LASIK, Tokyo,

More information

ReLEx smile Minimally invasive vision correction Information for patients

ReLEx smile Minimally invasive vision correction Information for patients ReLEx smile Minimally invasive vision correction Information for patients Seeing is living Our eyes are our most important sensory organ. The human brain obtains over 80 % of its information via the sense

More information

The pinnacle of refractive performance.

The pinnacle of refractive performance. Introducing! The pinnacle of refractive performance. REFRACTIVE SURGERY sets a new standard in LASIK outcomes More than 98% of patients would choose it again. 1 It even outperformed glasses and contacts

More information

2. Materials and Methods

2. Materials and Methods Ophthalmology Volume 216, Article ID 267298, 7 pages http://dx.doi.org/1.1155/216/267298 Clinical Study Comparison of the Early Clinical Outcomes between Combined Small-Incision Lenticule Extraction and

More information

One of the exciting new research areas in laser

One of the exciting new research areas in laser Future Challenges to Aberration-free Ablative Procedures Cynthia Roberts, PhD One of the exciting new research areas in laser refractive surgery is the development of sophisticated devices to measure the

More information

The Efficacy of Multi-Zone Cross-Cylinder Method for Astigmatism Correction

The Efficacy of Multi-Zone Cross-Cylinder Method for Astigmatism Correction Korean J Ophthalmol Vol. 18:29-34, 2004 The Efficacy of Multi-Zone Cross-Cylinder Method for Astigmatism Correction Seong Joo Shin, MD, Hae Young Lee, MD Department of Ophthalmology, Seoul Adventist Hospital,

More information

How To Compare 3 Year Changes In Corneal Thickness After Photorefractive Keratectomy Or Laser In Situ Keratomileusis

How To Compare 3 Year Changes In Corneal Thickness After Photorefractive Keratectomy Or Laser In Situ Keratomileusis Three-Year Changes in Epithelial and Stromal Thickness after PRK or LASIK for High Myopia Anders Ivarsen, Walther Fledelius, and Jesper Ø. Hjortdal From the Department of Ophthalmology, Århus University

More information

your bestchoice for Laser Vision Correction www.aucklandeyelaser.co.nz

your bestchoice for Laser Vision Correction www.aucklandeyelaser.co.nz your bestchoice for Laser Vision Correction www.aucklandeyelaser.co.nz Auckland Eye is the Centre of Excellence for Laser Eye Surgery in Auckland Welcome to a life of freedom from contact lenses and glasses.

More information

Changes in central corneal thickness and refractive error after thin-flap laser in situ keratomileusis in Chinese eyes

Changes in central corneal thickness and refractive error after thin-flap laser in situ keratomileusis in Chinese eyes Zhao et al. BMC Ophthalmology (2015) 15:86 DOI 10.1186/s12886-015-0083-2 RESEARCH ARTICLE Open Access Changes in central corneal thickness and refractive error after thin-flap laser in situ keratomileusis

More information

Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques

Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques Julio Narváez MD Associate Professor of Ophthalmology Loma Linda University Non-Refractive Applications of Femtosecond

More information

Case Report Laser Vision Correction on Patients with Sick Optic Nerve: A Case Report

Case Report Laser Vision Correction on Patients with Sick Optic Nerve: A Case Report Case Reports in Ophthalmological Medicine Volume 2011, Article ID 796463, 4 pages doi:10.1155/2011/796463 Case Report Laser Vision Correction on Patients with Sick Optic Nerve: A Case Report Ming Chen

More information

Refractive Surgery. Common Refractive Errors

Refractive Surgery. Common Refractive Errors Refractive Surgery Over the last 25 years developments in medical technology and Refractive Surgery allow almost all need for glasses and contact lenses to be eliminated. Currently there are a number of

More information

LASIK. Complications. Customized Ablations. Photorefractive Keratectomy. Femtosecond Keratome for LASIK. Cornea Resculpted

LASIK. Complications. Customized Ablations. Photorefractive Keratectomy. Femtosecond Keratome for LASIK. Cornea Resculpted Refractive Surgery: Which Procedure for Which Patient? David R. Hardten, M.D. Minneapolis, Minnesota Have done research, consulting, or speaking for: Alcon, Allergan, AMO, Bausch & Lomb, Inspire, Medtronic,

More information

LASIK for Hyperopia With the WaveLight Excimer Laser

LASIK for Hyperopia With the WaveLight Excimer Laser LASIK for Hyperopia With the WaveLight Excimer Laser A. John Kanellopoulos, MD; Joseph Conway, MD; Lawrence H. Pe, MD ABSTRACT PURPOSE: To evaluate the safety and effi cacy of the ALLEGRETTO WAVE excimer

More information

Accelerated Refractive Performance

Accelerated Refractive Performance Accelerated Refractive Performance Get There at the Speed of WaveLight Designed to accommodate your refractive technology goals now and into the future, the WaveLight Workstation is a faster way to get

More information

Corporate Medical Policy Implantation of Intrastromal Corneal Ring Segments

Corporate Medical Policy Implantation of Intrastromal Corneal Ring Segments Corporate Medical Policy Implantation of Intrastromal Corneal Ring Segments File Name: Origination: Last CAP Review: Next CAP Review: Last Review: implantation_of_intrastromal_corneal_ring_segments 8/2008

More information

The Recovery of Optical Quality after Laser Vision Correction

The Recovery of Optical Quality after Laser Vision Correction pissn: 111-8942 eissn: 292-9382 Korean J Ophthalmol. 213 Forthcoming. Posted online 213 July 18 Original Article The Recovery of Optical Quality after Laser Vision Correction Hyeong-Gi Jung, Tae-Hyung

More information

Refractive Surgery Issue. Inlays and Presbyopia: On the Horizon P. 24. Crack a SMILE or Raise a Flap? P. 30. LASIK Xtra: Who Should Get It? P.

Refractive Surgery Issue. Inlays and Presbyopia: On the Horizon P. 24. Crack a SMILE or Raise a Flap? P. 30. LASIK Xtra: Who Should Get It? P. MULTIMODAL IMAGING OF PLACOID DISORDERS P. 42 WILLS RESIDENT CASE SERIES P. 67 NTG: THE NOCTURNAL BLOOD PRESSURE FACTOR P. 54 WISE CHOICES FOR OCULAR DIAGNOSES P. 50 NEW WAYS TO DETECT KERATOCONUS P. 58

More information

KERATOCONUS IS A BILATERAL, ASYMMETRIC, CHRONIC,

KERATOCONUS IS A BILATERAL, ASYMMETRIC, CHRONIC, Comparison of and Intacs for Keratoconus and Post-LASIK Ectasia MUNISH SHARMA, MD, AND BRIAN S. BOXER WACHLER, MD PURPOSE: To evaluate the efficacy of single-segment Intacs and compare with double-segment

More information

Cornea and Refractive Surgery Update

Cornea and Refractive Surgery Update Cornea and Refractive Surgery Update Fall 2015 Optometric Education Dinner Sebastian Lesniak MD Matossian Eye Associates Disclosures: None Bio: Anterior Segment and Cornea Surgery Fellowship Wills Eye

More information

Refractive Surgery. Evolution of Refractive Error Correction

Refractive Surgery. Evolution of Refractive Error Correction Refractive Surgery Techniques that correct for refractive error in the eye have undergone dramatic evolution. The cornea is the easiest place to place a correction, so most techniques have focused on modifying

More information

Long-Term Outcomes of Flap Amputation After LASIK

Long-Term Outcomes of Flap Amputation After LASIK Long-Term Outcomes of Flap Amputation After LASIK Priyanka Chhadva BS, Florence Cabot MD, Anat Galor MD, Sonia H. Yoo MD Bascom Palmer Eye Institute, University of Miami Miller School of Medicine Miami

More information

Active Cyclotorsion Error Correction During LASIK for Myopia and Myopic Astigmatism With the NIDEK EC-5000 CX III Laser

Active Cyclotorsion Error Correction During LASIK for Myopia and Myopic Astigmatism With the NIDEK EC-5000 CX III Laser Active Cyclotorsion Error Correction During LASIK for Myopia and Myopic Astigmatism With the NIDEK EC-5000 CX III Laser Sudhank Bharti, MD; Harkaran S. Bains ABSTRACT PURPOSE: To investigate the predictability

More information

LASIK SURGERY IN AL- NASSIRYA CITY A CLINICOSTATISTICAL STUDY

LASIK SURGERY IN AL- NASSIRYA CITY A CLINICOSTATISTICAL STUDY Thi-Qar Medical Journal (TQMJ): Vol(4) No(4):1(14-21) SUMMARY: LASIK SURGERY IN AL- NASSIRYA CITY A CLINICOSTATISTICAL STUDY Dr. Ali Jawad AL- Gidis (M.B.Ch.B., D.O., F.I.C.O.)* Background: LASIK which

More information

Case Reports Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking

Case Reports Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking Case Reports Post-LASIK ectasia treated with intrastromal corneal ring segments and corneal crosslinking Kay Lam, MD, Dan B. Rootman, MSc, Alejandro Lichtinger, and David S. Rootman, MD, FRCSC Author affiliations:

More information

LASIK SURGERY OUTCOMES, VOLUME AND RESOURCES

LASIK SURGERY OUTCOMES, VOLUME AND RESOURCES MOH Information Paper: 2006/17 LASIK SURGERY OUTCOMES, VOLUME AND RESOURCES By Dr. Ganga Ganesan 1 I INTRODUCTION LASIK stands for Laser-Assisted In Situ Keratomileusis and is a surgical procedure that

More information

publication list - SMILE - 05 2015

publication list - SMILE - 05 2015 2015 May J Cataract Refract Surg. Wang Y, Cui C, Li Z, Tao X, Zhang C, Zhang X, Mu G. Corneal ectasia 6.5 months after small-incision lenticule extraction ectasia 2015 May Ophthalmic Physiol Opt Gyldenkerne

More information

Collagen Cross-linking combined with PRK and LASIK

Collagen Cross-linking combined with PRK and LASIK Collagen Cross-linking combined with PRK and LASIK./*0&1#*!"#$%%&'&(%&)2*+,* +$345"%*,46$57&62*8")$694)4&#/:6*;#)%4#45"%*?6&@$))&62*ABC*8"#:&#$*+$345"%*D51&&%2*AB!"#$%%&'&(%&)*+,!

More information

Small Incision Corneal Refractive Surgery using the. Astigmatism: Results of a 6 months prospective study

Small Incision Corneal Refractive Surgery using the. Astigmatism: Results of a 6 months prospective study Small Incision Corneal Refractive Surgery using the procedure for the Correction of Myopia and Myopic Astigmatism: Results of a 6 months prospective study Walter Sekundo, MD 1, Kathleen S. Kunert 2, Marcus

More information

Medical Director, Shinagawa LASIK Center, Tokyo, Japan Adjunct Professor, Department of Ophthalmology, Wenzhou Medical College, Wenzhou, China

Medical Director, Shinagawa LASIK Center, Tokyo, Japan Adjunct Professor, Department of Ophthalmology, Wenzhou Medical College, Wenzhou, China Medical Director,, Tokyo, Japan Adjunct Professor, Department of Ophthalmology, Wenzhou Medical College, Wenzhou, China Financial disclosure: Ziemer Group AG, Switzerland AcuFocus, CA Schwind Eye-Tech-Solutions,

More information

The future of laser refractive surgery is exciting

The future of laser refractive surgery is exciting The Cornea is Not a Piece of Plastic Cynthia Roberts, PhD Editorial The future of laser refractive surgery is exciting with the potential for ever-improved postoperative visual performance. In the past,

More information

INTRACOR. An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the

INTRACOR. An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the INTRACOR An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the 1 Dr Luis Ruiz Presbyopia treatment with INTRACOR Luis

More information

TABLE OF CONTENTS: LASER EYE SURGERY CONSENT FORM

TABLE OF CONTENTS: LASER EYE SURGERY CONSENT FORM 1 BoydVision TABLE OF CONTENTS: LASER EYE SURGERY CONSENT FORM Risks and Side Effects... 2 Risks Specific to PRK... 3 Risks Specific to LASIK... 4 Patient Statement of Consent... 5 Consent for Laser Eye

More information

Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda

Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda Slit Skiascopic-guided Ablation Using the Nidek Laser Scott MacRae, MD; Masanao Fujieda ABSTRACT PURPOSE: To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with

More information

Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trial

Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trial Ang et al. Trials 2012, 13:75 TRIALS STUDY PROTOCOL Open Access Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority

More information

ALL-LASER LASIK USING THE ZEISS VisuMax MEL 80 REFRACTIVE WORKSTATION

ALL-LASER LASIK USING THE ZEISS VisuMax MEL 80 REFRACTIVE WORKSTATION ALL-LASER LASIK USING THE ZEISS VisuMax MEL 80 REFRACTIVE WORKSTATION A two-center study related to clinical outcome for all-laser LASIK corrections using the VisuMax MEL80 TM workstation RAINER WILTFANG,

More information

Intracorneal Ring Segments Implantation Followed by Same-day Topography-guided PRK and Corneal Collagen CXL in Low to Moderate Keratoconus

Intracorneal Ring Segments Implantation Followed by Same-day Topography-guided PRK and Corneal Collagen CXL in Low to Moderate Keratoconus SURGICAL TECHNIQUE Intracorneal Ring Segments Implantation Followed by Same-day Topography-guided PRK and Corneal Collagen CXL in Low to Moderate Keratoconus Waleed Al-Tuwairqi, MD; Mazen M. Sinjab, MD,

More information

Wavefront-guided Custom Ablation for Myopia Using the NIDEK NAVEX Laser System

Wavefront-guided Custom Ablation for Myopia Using the NIDEK NAVEX Laser System Wavefront-guided Custom Ablation for Myopia Using the NIDEK NAVEX Laser System Jan Venter, MD ABSTRACT PURPOSE: To determine the predictability, effi cacy, safety, and stability of LASIK using custom ablation

More information

Good Reasons to SMILE Latest clinical experiences with minimally invasive, fl apless surgery

Good Reasons to SMILE Latest clinical experiences with minimally invasive, fl apless surgery Supplement to September 2015 Sponsored by ZEISS Good Reasons to SMILE Latest clinical experiences with minimally invasive, fl apless surgery SMILE 3 rd Generation LASIK 2 nd Generation PRK 1 st Generation

More information

JRS Standard for Reporting Astigmatism Outcomes of Refractive Surgery

JRS Standard for Reporting Astigmatism Outcomes of Refractive Surgery EDITORIAL JRS Standard for Reporting Astigmatism Outcomes of Refractive Surgery Dan Z. Reinstein, MD, MA(Cantab), FRCOphth; Timothy J. Archer, MA(Oxon), DipCompSci(Cantab); J. Bradley Randleman, MD S tandardization

More information

Laser in situ keratomileusis (LASIK) has been. Retreatment of Hyperopia After Primary Hyperopic LASIK REPORTS

Laser in situ keratomileusis (LASIK) has been. Retreatment of Hyperopia After Primary Hyperopic LASIK REPORTS REPORTS Retreatment of Hyperopia After Primary Hyperopic LASIK Julio Ortega-Usobiaga, MD, PhD; Rosario Cobo-Soriano, MD, PhD; Fernando Llovet, MD; Francisco Ramos, MD; Jaime Beltrán, MD; Julio Baviera-Sabater,

More information

Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision

Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision Customized Corneal Ablation and Super Vision Scott M. MacRae, MD; James Schwiegerling, PhD; Robert Snyder, MD, PhD ABSTRACT PURPOSE: To review the early development of new technologies that are becoming

More information

SCHWIND CAM Perfect Planning wide range of applications

SCHWIND CAM Perfect Planning wide range of applications SCHWIND CAM Perfect Planning wide range of applications ORK-CAM PresbyMAX PALK-CAM PTK-CAM 2 SCHWIND CAM the system solution The latest version of the modular SCHWIND CAM represents an even more efficient

More information

Financial Disclosure. LASIK Flap Parameters IntraLase Microkeratome 6/9/2008. Femtosecond LASIK Flaps: What Could We Customize Yesterday?

Financial Disclosure. LASIK Flap Parameters IntraLase Microkeratome 6/9/2008. Femtosecond LASIK Flaps: What Could We Customize Yesterday? Financial Disclosure Arturo Chayet, MD Tijuana, BC Mexico Perry S. Binder, MS, MD San Diego CA USA I have the following financial interests or relationships to disclose: AMO/IntraLase Corporation - C Acufocus

More information

ZEISS Refractive Technologies Opt for excellence when performing 2 nd Generation Laser Vision Correction

ZEISS Refractive Technologies Opt for excellence when performing 2 nd Generation Laser Vision Correction Insert to July/August 2015 Sponsored by ZEISS ZEISS Refractive Technologies Opt for excellence when performing 2 nd Generation Laser Vision Correction PRK 1 st Generation LASIK 2 nd Generation SMILE 3

More information

Our Commitment To You

Our Commitment To You SYSTEM SUPPORT Quality-crafted, the system boasts dependability with high efficiency and low gas usage. We provide responsive service and maintenance contract options, supported by our nationwide direct

More information

Topographically-guided Laser In Situ Keratomileusis to Treat Corneal Irregularities

Topographically-guided Laser In Situ Keratomileusis to Treat Corneal Irregularities Topographically-guided Laser In Situ Keratomileusis to Treat Corneal Irregularities Michael C. Knorz, MD, Bettina Jendritza, MD Objective: To evaluate the predictability and safety of topographically guided

More information

Dr. Booth received his medical degree from the University of California: San Diego and his bachelor of science from Stanford University.

Dr. Booth received his medical degree from the University of California: San Diego and his bachelor of science from Stanford University. We've developed this handbook to help our patients become better informed about the entire process of laser vision correction. We hope you find it helpful and informative. Dr. Booth received his medical

More information

Consumer s Guide to LASIK

Consumer s Guide to LASIK Consumer s Guide to LASIK A Community Service Project brought to you by Price Vision Group Your Guide To A Successful LASIK Procedure The purpose of this educational guide is to help prospective patients

More information

Laser in situ keratomileusis for mixed astigmatism using a modified formula for bitoric ablation

Laser in situ keratomileusis for mixed astigmatism using a modified formula for bitoric ablation European Journal of Ophthalmology / Vol. 18 no. 6, 2008 / pp. 869-876 Laser in situ keratomileusis for mixed astigmatism using a modified formula for bitoric ablation D. DE ORTUETA, C. HAECKER Augenlaserzentrum

More information

Simultaneous Correction of Unilateral Rainbow Glare and Residual Astigmatism by Undersurface Flap Photoablation After Femtosecond Laser-Assisted LASIK

Simultaneous Correction of Unilateral Rainbow Glare and Residual Astigmatism by Undersurface Flap Photoablation After Femtosecond Laser-Assisted LASIK THERAPEUTIC REFRACTIVE SURGERY Simultaneous Correction of Unilateral Rainbow Glare and Residual Astigmatism by Undersurface Flap Photoablation After Femtosecond Laser-Assisted LASIK Damien Gatinel, MD;

More information

Long-term stability of the posterior cornea after laser in situ keratomileusis

Long-term stability of the posterior cornea after laser in situ keratomileusis ARTICLE Long-term stability of the posterior cornea after laser in situ keratomileusis Joseph B. Ciolino, MD, Stephen S. Khachikian, MD, Michael J. Cortese, OD, Michael W. Belin, MD PURPOSE: To study long-term

More information

The concept of a proactive intervention involving in situ

The concept of a proactive intervention involving in situ CLINICAL SCIENCE Epithelial Remodeling After Femtosecond Laser-assisted High Myopic LASIK: Comparison of Stand-alone With LASIK Combined With Prophylactic High-fluence Cross-linking Anastasios J. Kanellopoulos,

More information

Patient-Reported Outcomes with LASIK (PROWL-1) Results

Patient-Reported Outcomes with LASIK (PROWL-1) Results Patient-Reported Outcomes with LASIK (PROWL-1) Results Elizabeth M. Hofmeister, MD CAPT, MC, USN Naval Medical Center San Diego Refractive Surgery Advisor for Navy Ophthalmology Assistant Professor of

More information

refractive surgery a closer look

refractive surgery a closer look 2011-2012 refractive surgery a closer look How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly onto the retina, the light-sensitive

More information

Wavefront-guided Enhancements Using the WaveLight Excimer Laser in Symptomatic Eyes Previously Treated With LASIK

Wavefront-guided Enhancements Using the WaveLight Excimer Laser in Symptomatic Eyes Previously Treated With LASIK Wavefront-guided Enhancements Using the WaveLight Excimer Laser in Symptomatic Eyes Previously Treated With LASIK A. John Kanellopoulos, MD; Lawrence H. Pe, MD ABSTRACT PURPOSE: To describe our clinical

More information

final corrected draft

final corrected draft Archived at the Flinders Academic Commons http://dspace.flinders.edu.au/dspace/ This is the author s final corrected draft of this article. It has undergone peer review. Citation for the publisher s version:

More information

LASIK in the Presbyopic Age Group

LASIK in the Presbyopic Age Group LASIK in the Presbyopic Age Group Safety, Efficacy, and Predictability in 40- to 69-Year-Old Patients Ramon C. Ghanem, MD, 1,2 Jose de la Cruz, MD, 1,2 Faisal M. Tobaigy, MD, 1 Leonard P. K. Ang, FRCS(Ed),

More information

Total Corneal Astigmatism Correction With Limbal Relaxing Incisions Made by Femtosecond Laser System

Total Corneal Astigmatism Correction With Limbal Relaxing Incisions Made by Femtosecond Laser System Total Corneal Astigmatism Correction With Limbal Relaxing Incisions Made by Femtosecond Laser System Pilavas J 2, Nissirios N 1,2, Hatsis A 1,2 1 Long Island Vision Experts, Rockville Centre, NY and 2

More information

Clinical Study Corneal Epithelial Remodeling after LASIK Measured by Fourier-Domain Optical Coherence Tomography

Clinical Study Corneal Epithelial Remodeling after LASIK Measured by Fourier-Domain Optical Coherence Tomography Ophthalmology Volume 2015, Article ID 860313, 5 pages http://dx.doi.org/10.1155/2015/860313 Clinical Study Corneal Epithelial Remodeling after LASIK Measured by Fourier-Domain Optical Coherence omography

More information

Comparison of Two Procedures: Photorefractive Keratectomy Versus Laser In Situ Keratomileusis for Low to Moderate Myopia

Comparison of Two Procedures: Photorefractive Keratectomy Versus Laser In Situ Keratomileusis for Low to Moderate Myopia Comparison of Two Procedures: Photorefractive Keratectomy Versus Laser In Situ Keratomileusis for Low to Moderate Myopia Jae Bum Lee, Jae Sung Kim, Chul-Myong Choe, Gong Je Seong and Eung Kweon Kim Institute

More information

Early Clinical Outcomes of Wavefront-Guided Myopic LASIK Treatments Using a New- Generation Hartmann-Shack Aberrometer

Early Clinical Outcomes of Wavefront-Guided Myopic LASIK Treatments Using a New- Generation Hartmann-Shack Aberrometer ORIGINAL ARTICLE Early Clinical Outcomes of Wavefront-Guided Myopic LASIK Treatments Using a New- Generation Hartmann-Shack Aberrometer Steven Schallhorn, MD; Mitch Brown, OD; Jan Venter, MD; David Teenan,

More information

Lasik Xtra in: Hyperopia AK Xtra Clear cornea cataract surgery

Lasik Xtra in: Hyperopia AK Xtra Clear cornea cataract surgery Lasik Xtra in: Hyperopia AK Xtra Clear cornea cataract surgery A. John Kanellopoulos, M.D. Clinical Profesor of Ophthalmology New York University School of Medicine, New York, NY, USA Laservision.gr Institute,

More information

How To Implant A Keraring

How To Implant A Keraring Corneal Remodeling Using the Keraring A variety of thicknesses, arc lengths, and optical zone sizes allows tailoring of the procedure to the individual patient. BY DOMINIQUE PIETRINI, MD; AND TONY GUEDJ

More information

Keratorefractive Surgery for Post-Cataract Refractive Surprise. Moataz El Sawy

Keratorefractive Surgery for Post-Cataract Refractive Surprise. Moataz El Sawy Keratorefractive Surgery for Post-Cataract Refractive Surprise Moataz El Sawy Departmentof Ophthalmology, Faculty of Medicine,MenoufiyaUniversity, Egypt mfelsawy@yahoo.co.uk Abstract: Purpose: To evaluate

More information

VISX Wavefront-Guided LASIK for Correction of Myopic Astigmatism, Hyperopic Astigmatism and Mixed Astigmatism (CustomVue LASIK Laser Treatment)

VISX Wavefront-Guided LASIK for Correction of Myopic Astigmatism, Hyperopic Astigmatism and Mixed Astigmatism (CustomVue LASIK Laser Treatment) CustomVue Advantage Patient Information Sheet VISX Wavefront-Guided LASIK for Correction of Myopic Astigmatism, Hyperopic Astigmatism and Mixed Astigmatism (CustomVue LASIK Laser Treatment) Statements

More information

MicroScan. Excimer laser system for all types of vision corrections OPTOSYSTEMS LTD.

MicroScan. Excimer laser system for all types of vision corrections OPTOSYSTEMS LTD. MicroScan Excimer laser system for all types of vision corrections OPTOSYSTEMS LTD. МicroScan is a new generation excimer laser system for all types of vision corrections: myopia, hypermetropia, astigmatism.

More information