1 INDOOR AIR QUALITY : INDOOR AIR QUALITY TO MAXIMISE PRODUCTIVITY By: Ir. Ng Yong Kong 26 TH March Indoor Environmental Quality (IEQ) Primary areas of concern in IEQ Air Quality and Ventilation Thermal Comfort: Design & Controllability of Systems Lighting and Visual Perception Acoustic and Noise Comfort 1

2 1. Indoor Environmental Quality (IEQ) More than just Indoor Air Quality (IAQ) HVAC system provides a comfortable environment for building occupants and contributes significantly to Indoor Health Environment IAQ Definitions by WHO - The physical and chemical nature of indoor air, as delivered to the breathing zone of building occupants, which produces a complete state of mental, physical and social well-being of the occupants, and not merely the absence of disease or infirmity. Good IAQ may be defined as air with no known contaminants at harmful concentrations. Common contaminants or pollutants include gaseous pollutants, such as carbon dioxide (produced by occupants and from combustion appliances), volatile organic compounds (released by carpet glue and other materials), odours and particulates. Good IAQ is essential to ensure the health and comfort of occupants. 2

3 Factors that increase our exposure to indoor air pollutants Reduced ventilation rates to conserve energy The use of synthetic building materials and furnishings The use of chemically formulated personal care products, pesticides, printing inks, and household cleaners. Pollutant Sources Indoor sources Combustion sources Building materials and furnishings Asbestos-containing insulation Household cleaning products HVAC systems Occupants and activities Outdoor sources Radon Pesticides Outdoor air pollution 3

4 Why do we air-condition our buildings? Control Temperature Control Humidity/Moisture Control Air Movement Control Air Quality Control Noise and glare Control the environment increase productivity and comfort Pollutants Types Sick building syndrome (SBS) Sick building syndrome (SBS) is a condition that may be experience by occupants of the buildings. The symptoms include headaches, eye strain and lung irritation. Usually the symptoms disappear when the affected person leaves the mal-functioning building and are of short duration. Sick building syndrome occurs in the buildings which may have a number of defects, including inadequate ventilation, low light levels and /or flickering light fittings, excessive odours, high ambient noise levels, lack of local controls and other factors. 4

5 Pollutants Types Sick building syndrome (SBS) Typically inadequate ventilation may be due to insufficient supplies of fresh air, excessive recirculation of air, poorly maintained air handling units (i.e. filters not replace when needed) or a poorly designed and / or installed ductwork system. Low light levels are the result of light fittings not being replaced, the wrong type of fitting being used, poor lighting controls and / or insufficient numbers of light fittings being installed. Poor levels of daylighting can have the same effect. Pollutants Types Sick building syndrome (SBS) Excessive odours may be due to a poorly designed/installed kitchen ventilation system and inadequate ventilation rates. High noise levels may be present due to the proximity of a space to and adjacent busy road and / or a plant room, insufficient sound insulation and lack of sound absorption materials used on wall and ceiling surfaces. No local controls may be available for an occupant not adjacent to an openable window or window or an adjustable thermostat (in many cases local thermostats may be disabled to prevent excessive adjustment by occupants). 5

6 Pollutants Types Sick building syndrome (SBS) The existence and extent of SBS may be established using questionnaires. Occupants are asked to score their satisfaction level for ambient variables including air temperature, perceived humidity level, local (fresh) air flow, noise, task lighting, glare and odours, and their ability to control some of these values. Pollutants Types Sick building syndrome (SBS) Analysis is then performed on the data to determine whether conditions are satisfactory for the occupants in each assessed area. Results should indicate what modifications might be required to achieve acceptable thermal, lighting and acoustic conditions. In relation to ventilation, this may include increased fresh air flow rates, adjustment of diffusers, more frequent maintenance of ventilation plant and improved occupant access to controls. 6

7 Pollutants Types External (outdoor) air pollution Poor outdoor air quality will have significant impact on indoor air quality. External pollutants include vehicle exhausts, discharges from combustion appliances, industrial process and power station exhausts. Fungal spores and pollen from vegetation may also cause air quality problems. Vehicle exhausts include CO, CO 2, NO x and SO 2, particulates (especially from diesel engines) and VOCs (e.g from petrol and oil). Pollutants Types External (outdoor) air pollution Ozone is generated by the action of sunlight on nitrous oxides (present in vehicle exhausts). Power station release the same pollutants to vehicles, but are usually located in rural or semi-rural areas, so the impact of their pollutants is much reduced. In urban areas, traffic is a significant contributor to external pollution, with additional pollutant emissions coming from building exhausts and industrial processes. 7

8 Outdoor Air Quality Motorists passed a highway toll gate covered by thick haze in Kuala Lumpur, Malaysia, Thursday, Aug. 11, The ominous haze that has shrouded parts of Southeast Asia this month is just one visible element of a much larger problem that is choking hundreds of thousands to death every year across the region, the World Health Organization said. (AP Photo/Andy Wong) What Are OA Intake Restrictions? Significant contaminated exhaust Noxious or dangerous exhaust Chimneys and flues Truck loading area Driveway, street Thoroughfare w/high traffic Garbage dumpster Cooling tower 8

9 RNC/NRNC - Air Cool Split Units It basically comprises an indoor unit with the evaporator and blower and an outdoor unit with the compressor, condenser coil and fan coupled with refrigeration piping. The indoor units is often known as Fan Coil Units ( FCUs )and the outdoor units known as Condensing Units.( C.U.) As a whole, they are known as the Air Cooled Split Units. (ACSUs) Air Cooled Split Units Warm air (recirculating) Fan Coil Unit Cool air Outdoor air Condensing Unit 9

10 Air Cooled Split Units (ACSUs) Inverter type Both indoor and outdoor units are housed in robust casings. The outdoor unit is basically the same construction for all the various types of indoor units. The difference lies in the type of indoor unit. Cassette Wall Mounted Floor Standing Ceiling Exposed Air Cooled Split Units Many Business Establishments are housed in Small Premises using ACSUs. Office Restaurant 10

11 ACSUs ( incld. Inverter type ) : Fresh Air Intake? The wall mounted, floor standing and under ceiling split system has no provision for intake of outdoor air and/or exhaust of stale room. air. Room air is just filtered and recirculated. Can you consider this for large buildings? 11

12 Ducted Systems Introducing OA IAQ Definitions Building-Related Illness (BRI) is a term referring to illness brought on by exposure to the building air, where symptoms of diagnosable illness are identified and can be directly attributed to environmental agents in the air. Eg. of BRI is Legionnaires Disease commonly found in aquatic environment. 12

13 CODES and STANDARDS FOR IAQ PERFORMNCE AND THERMAL COMFORT EQ1: Minimum IAQ Performance Meet the minimum requirements of ventilation rate in ASHRAE Standard 62.1:2010 or the local building code whichever is the more stringent. 13

14 ASHRAE STD Ventilation For Acceptable For Indoor Air Quality Ventilation is the key to Sustainable IAQ and ASHRAE Std 62.1 is the most widely recognised Standard Internationally by most countries and HVAC Engineers in the world. EQ1: Minimum IAQ Performance MS 1525: Air Conditioning and Mechanical Ventilation (ACMV) System Indoor Design Condition Recommended Design DB Temperature 23-26ºC ( F ) Minimum DB Temperature 22ºC Recommended Design RH 55% - 70% Recommended Air Movement 0.15 m/s 0.50m/s Maximum Air Movement 0.7 m/s Outdoor Design Conditions Recommended Outdoor Design 33.3ºC / 27.2ºC Conditions DB / WB ( 92 F/ 81 F ) 14

15 Industry Code of Practice on Indoor Air Quality 2010 DOSH Malaysia* Ministry of Human Resources Table 1: List of Indoor Air Contaminants and the Maximum Limits Acceptable Range for Specific Physical Parameters 2010 Parameter Acceptable range (a) (b) (c) Air temperature Relative humidity Air movement ºC 40 70%

16 List of Indoor Air Contaminants and acceptable limits Indoor Air Contaminants Eight-hours time-weighted average airborne concentration ppm mg/m³ cfu/m³ Chemical contaminants (a) Carbon dioxide (b) Carbon monoxide (c) Formaldehyde (d) Ozone (e) Respirable particulates (f) Total volatile organic compounds (TVOC) C Biological contaminants (a) Total bacterial counts (b) Total fungal counts ASHRAE Standard Specifies conditions likely to be thermally acceptable to at least 80% of the adult occupants in a space 16

17 Indoor Environmental Quality Thermal Comfort (EQ6) Design to ASHRAE : Thermal Environmental Conditions for Human Occupancy in conjunction with relevant localised parameters as listed in MS 1525:2007 Specifies Conditions likely to be thermally acceptable to at least 80% of the adult occupants in a space 6 Primary factors that must be addressed when defining conditions for thermal comfort are: 1.) Metabolic rate 2.) Clothing insulation 3.) Air temperature 4.) Radiant temperature 5.) Air speed 6.) Humidity 17

18 1.) Factors affecting comfort and Indoor Air Quality (IAQ) Space Temperature Relative Humidity Air Velocity Noise and Acoustic Level Ventilation - Supply of Acceptable Air & removal of Unacceptable Air Lack of Maintenance of ACMV ( HVAC ) system ( eg. Filters not cleaned or replace regularly ) What are the IAQ Problems in Buildings? IAQ during design and construction Lack of Commissioning Moisture in Building Assemblies Poor Outdoor Air Quality Moisture and Dirt in Ventilation Indoor Contaminant Sources Contaminants from Indoor Equipment and Activities Inadequate Ventilation Rates Ineffective Filtration and Air Cleaning 18

19 Minimum IAQ Performance *EQ1: Minimum IAQ Performance Meet the minimum requirements of ventilation rate in ASHRAE Standard 62.1:2007 or the local building code whichever is the more stringent. MS 1525:2007 Section Ventilation Outdoor Air-Ventilation Rates should comply with Third Schedule (By Law 41) Article 12 (1) of Uniform Building By Laws, 1984 ( UBBL ) 19

20 Building code requirements Extract from Third Schedule (By-law 41) ASHRAE Comfort Zone 20

21 ASHRAE STD Ventilation For Acceptable For Indoor Air Quality Ventilation is the key to Sustainable IAQ and ASHRAE Std 62.1 is the Leading Standard adopted by most Local Authorities and HVAC Engineers in the world. EQ1: Minimum IAQ Performance ASHRAE Std Ventilation For Acceptable Indoor Air Quality 1.) Ventilation Rate Procedure ( VRP ) 2.) Indoor Air Quality Procedure ( IAQ ) 3.) Natural Ventilation permitted to be used in conjunction with Mechanical Ventilation. 21

22 Acceptable Indoor Air Quality is defined as air in which there are no known Contaminants at harmful Concentrations as determined by Cognizant Authorities and with which a substantial majority ( 80% or more ) of the people exposed do not express dissatisfaction. 1.) Ventilation Rate Procedure ( VRP ) is a prescriptive procedure with a table of minimum required outdoor airflow rates per occupant for a variety of nonresidential occupancies. The airflow rate per square foot of building floor area is basedon the design occupancy density and the required flow rate per person, adjusted to reflect the air distribution system used. 1.) Ventilation Rate Procedure ( VRP ) V bz = R p.p z + R A.A Z ( PEOPLE + AREA COMPONENT ) Where V bz = Design outdoor airflow required in the breathing zone of the occupied space or spaces in a zone,i.e the breathing zone outdoor air flow A z = Zone floor area: the net occupiable floor area of the zone m 2 ( ft 2 ) P z = zone population: the largest number of people expected to occupy the zone during typical usage. R p = outdoor airflow rate required per person as determined from Table 6-1 R a = outdoor airflow rate required per unit area as determined from Table

23 TABLE 6-1 MINIMUM VENTILATION RATES IN BREATHING ZONE People Outdoor Area Outdoor Default Values Occupancy Air Rate Air Rate Category R p Ra Office Buildings cfm/ person COPY L/s person cfm/ft ² L/s m² Occupant Density #1000 ft² cfm/ or #100 m² person Combined Outdoor Air Rate L/s person Office Space Reception areas TABLE 6-1 MINIMUM VENTILATION RATES IN BREATHING ZONE Hotels, Motels, Resort, Dormitories Bedroom / living room Barracks sleeping areas Laundry rooms, central Laundry rooms within dwelling units Lobbies / pre-function Multipurpose assembly

24 ASHRAE Std Ventilation For Acceptable Indoor Air Qualy 1.) Example : Ventilation Rate Procedure ( VRP ) V bz = R p.p z + R a.a z Where V bz = Design outdoor airflow required A z = floor area = 1,000 sq. ft., P z = population = 5 people (20m2/person ) R p = outdoor airflow rate required per person as determined from Table 6-1 = 5 cfm/person R a = outdoor airflow rate required per unit area as determined from Table 6-1 = 0.06 cfm/ft2 V bz = R p.p z + R a.a z = 5 x x 1,000 = 85 cfm i.e 17cfm/person ASHRAE Std Ventilation For Acceptable Indoor Air Qualy 2.) Example : Ventilation Rate Procedure ( VRP ) V bz = R p.p z + R a.a z Where V bz = Design outdoor airflow required A z = floor area = 10,000 sq. ft., P z = population = 100 people R p = outdoor airflow rate required per person as determined from Table 6-1 = 5 cfm/person R a = outdoor airflow rate required per unit area as determined from Table 6-1 = 0.06 cfm/ft2 V bz = R p.p z + R a.a z = 5 x x 10,000 = 1,100 cfm i.e 11cfm/person 24

25 ASHRAE Std Ventilation For Acceptable Indoor Air Quality Ventilation Rate Procedure ( VRP ) V bz = R p.p z + R a.a z Where V bz = Design outdoor airflow required Eg. 2 Banks or bank lobbies ( Default Values ) A z = floor area = 100 m2, P z = population = 15 people R p = outdoor airflow rate required per person as determined from Table 6-1 = 3.8 L/s.person R a = outdoor airflow rate required per unit area as determined from Table 6-1 = 0.3 L/s.m2 V bz = R p.p z + R a.a z = 3.8 x x 100 = = 87 L/s = 6.0 L/s.person MINIMUM VENTILATION RATES IN BREATHING ZONE Occupancy People Outdoor Area Outdoor Design Values Air Rate Air Rate Occupant Density Combined Outdoor Category R p Ra Air Rate cfm/ person L/s person cfm/ft ² L/s m² #1000 ft² cfm/ or #100 m² person L/s person Office Buildings Office Space Banks or Bank lobbies ft2/person ft2/person

26 MINIMUM VENTILATION RATES IN BREATHING ZONE Occupancy Category People Outdoor Area Outdoor Design Values Air Rate R p Air Rate Ra Occupant Density Combined Outdoor Air Rate cfm/ person L/s person cfm/ft² L/s m² #1000 ft² or #100 m² cfm/ person L/s person Hotels, Motels, Resort, Dormitories Places of religious worship ft2/person Libraries ft2/person Retail Mall common areas ft2/person Lecture Classroom ft2/person MINIMUM VENTILATION RATES IN BREATHING ZONE Occupancy Category People Outdoor Area Outdoor Design Values Air Rate R p Air Rate Ra Occupant Density Combined Outdoor Air Rate cfm/ person L/s person cfm/ft² L/s m² #1000 ft² or #100 m² cfm/ person L/s person Hotels, Motels, Resort, Dormitories Lobbies/ prefunction Multi purpose assembly Educational Facilities Computer lab Restaurant Dining rooms ft2/person ft2/person ft2/person 50 10ft2/person

27 Air Classification and Recirculation Class 1: Air with low contaminant concentration, low sensory-irritation intensity, and inoffensive odor. Class 2: Air with moderate contaminant concentration, mild sensory-irritation intensity, or mildly offensive odors. Class 2 air also includes air that is not necessarily harmful or objectionable but that is inappropriate for transfer or recirculation to spaces used for different purposes. 27

28 28

29 Variable Refrigerant System ( VRS )/ Variable Refrigerant Flow ( VRF ) On a single refrigerant pipe, many indoor units can be connected. Many Fan Coil Units ( up to 60 units) Remedial measures- 1.HVAC Specifying engineers Cassette unit with fan, filter and ducting for outdoor air Ashrae Malaysia Chapter one day seminar April

30 Remedial measures-1.hvac Specifying engineers Cassette unit with fan, filter and ducting for outdoor air Ashrae Malaysia Chapter one day seminar April ASHRAE Std Ventilation For Acceptable Indoor Air Quality 2.) Indoor Air Quality Procedure ( IAQ ) is a performance based design approach in which the building and its ventilation system are designed to maintain the concentrations of specific contaminants at or below certain limits identified during the building design and to achieve the design target level of perceived IAQ acceptability by occupants. 30

31 ASHRAE Std Ventilation For Acceptable Indoor Air Quality 2.) Indoor Air Quality Procedure ( IAQ ) It provides an engineered approach to an acceptable IAQ in a building :- i) identify contaminants of concern ii) likely rates of generation and acceptable levels of these contaminants iii) defining a system and outdoor ventilation rate that together will maintain the contaminants concentration below maximum acceptable level Air Purification to remove some or all of the contaminants of concern can be part of the system ASHRAE Standard , Ventilation for Acceptable Indoor Air Quality, specifies minimum ventilation rates and indoor air quality that will be acceptable to the human occupants of a building. Considers chemical, physical, and biological contaminants. Table 6-1 Minimum Ventilation Rates in Breathing Zone (PEOPLE COMPONENT ONLY ) Rp, Flow rate per person or per unit area (ASHRAE ) e.g. Office space 5cfm/person Mall & supermarket 7.5 cfm/person Restaurant & Café 7.5 cfm/person Lecture hall 7.5 Cfm/person Games arcade / Casino 7.5 Cfm/person Computer & Science Lab 10 Cfm/person Disco & Aerobics room 20 Cfm/person 31

32 COST OF USING HIGH FA At Ambient of 92 F DB/81 FWB (33.3 C/ 27.2 C) Cfm ( 300 M³/Hr) of FA Requires 1 Ton ( 3.517KW ) of AC Load High use of Fresh Air Results in High Capital Cost High Operating Cost (Energy & Water Cost) 63 ASHRAE STANDARDS 62 Ventilation for Acceptable Indoor Air Quality LOCATION OFFICE SPACE OA REQUIRMENTS FOR VENTILATION CFM/Person ( ,1999 & 2001) CFM/PERSON 20 MIN.VENTILATION RATES IN BREATHING ZONE ( & 2007) CFM/Person 5 CONFERENCE ROOM CFM/PERSON 20 CFM/Person

33 ASHRAE STANDARDS 62.1 Ventilation for Acceptable Indoor Air Quality LOCATION AUDITORIUM CLASS ROOM OA REQUIRMENTS FOR VENTILATION CFM/Person ( ,1999 & 2001) CFM/PERSON 20 CFM/PERSON 20 MIN.VENTILATION RATES IN BREATHING ZONE ( ,2007 & 2010 ) CFM/Person 5 ( People Component) CFM/Person 7.5 (People Component) 65 CALCULATION FOR ENERGY SAVINGS WITH REDUCTION OF OUTDOOR AIR 66 33

34 ASHRAE (Cfm/person) (Cfm/person) OFFICE 20 5 (15) 67 DB WB ENTHALPY F F Btu/lb of dry air OUTDOOR AIR DESIGN TEMP

35 FOR AN OFFICE WITH 200 PERSONS Savings = 4.45 x CFM x Enthaply = 4.45 x (200 x 15) x = 17.2 tons (60.5kw) 69 No of People Savings in Chiller Tonnage ton (30.3KW) ton (60.5KW) ton (151.3KW) 1, ton (302.6KW) 2, ton (605.3KW) 70 35

36 36

37 37

38 38

39 CO2 Monitoring and Demand Control Ventilation ( EQ3) Ventilation Is Fixed Question: How could we ventilate the space more efficiently? Answers: Measure Ventilation In The Space Like Temperature Vary Ventilation Based On Occupancy Zone Control Ventilation With CO 2 39

40 The effect of CO 2 on man 8,0% Convulsions, immediate paralysis and death Main alarm 3,0% Muscular pain, unconsciousness, convulsions and risk of death Pre alarm 1,50% 0,50% 0,10% 0,04% Shortness of breath and increased heart frequency Hygienic limit value Recommended indoor limit value Fresh air Carbon Dioxide and DCV. Humans are the main indoor source of CO2. Indoor carbon dioxide concentrations can be used to indicate specific and limited aspects of indoor air quality but are not an overall indicator of the quality of indoor air. Demand Control Ventilation adjusts ventilation air based on the number of occupants and the ventilation demands that the occupants create. 40

41 Carbon Dioxide and DCV (2) CO 2 -based DCV has the most energy savings potential in buildings where occupancy fluctuates & when ventilation is over designed. Office buildings, government facilities, retail stores and shopping malls, airports, theaters, auditoriums, conference or lecture halls, entertainment areas are good candidates for DCV CO 2 Demand Controlled Ventilation Examples: Assuming a Conference room with Max. capacity of = 200 people If Designed Ventilation rate = 7 l/s/ person The Amount of ventilation required = 1,400 l/s Now if the Conference room is not fully occupied, say with No. of People = 70 If Ventilation rate is maintained at 7 l/s/ person Amount of ventilation = 490 l/s DCV uses CO2 measurement to indirectly determine level of occupancy and thus ventilation 41

42 Typical Installation AHU Room Return Air CO2 sensor AHU Room AHU Supply Air Fresh Air Fresh air damper Damper Actuator Typical Installation AHU Room Return Air CO 2 sensor AHU Room Return Air AHU Supply Air CO 2 sensor PLC Fresh Air Fresh air damper Damper Actuator 42

43 Carbon Dioxide (CO 2 ) Sensors/Controllers Wall Mount Application Duct Mount Application Great potential for Energy savings when: i.) the space has less than maximum occupancy ii.) the space has variable occupancy pattern iii.) the ventilation is over designed Sensors are recommended to be verified every 3 years n = # of sensors R = terminating resistor 500 n Ω R 2-10 V input 4 20 ma Com V G+ G 0 I 0 G+ G 0 I 0 CO 2 sensor CO 2 sensor 3ph Supply Variable Speed Drive G+ G 0 I 0 CO 2 sensor G+ G 0 I 0 CO 2 sensor FAN Averaging CO 2 Sensor Monitoring & Control using VSD G+ G 0 I 0 CO 2 sensor 43

44 IAQ Before and During Occupancy All ventilation air filters will be changed after the flush-out Pressure sensor to detect filter blockage Purging to eliminate bad odors and improve air quality especially for building space that does not have adequate openable windows Ventilation of the encapsulation, hood or extraction type should be provided so that the spread of contaminants is prevented Building materials and surface finishes should not contain any substances that emit chemicals, bacteria or fungi THANK YOU By: Ir. Ng Yong Kong, ( nyk@nyk.com.my h/p no ) and others. 26 th March

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng. HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains

More information

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce

More information

How To Design A Building In New Delhi

How To Design A Building In New Delhi ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption

More information

THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM

THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM 1 Application Note AT-102 THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM Lawrence B. Kilham 1 and Randall M. Dodd 2 1 Eco Sensors, Inc. Santa Fe, New Mexico, USA larry@ecosensors.com

More information

IEQ-15 Air Distribution System

IEQ-15 Air Distribution System AIM OF CREDIT To encourage and recognise the design and maintenance of air distribution systems that minimise the risk of particulate and microbial contamination to the internal air supply. CREDIT CRITERIA

More information

AG-TQS-IAQ-00 March 4, 2002. Application Guide. TQS with IAQ Inlet

AG-TQS-IAQ-00 March 4, 2002. Application Guide. TQS with IAQ Inlet Application Guide TQS with IAQ Inlet Table of Contents Introduction 2 ASHRAE Standard 62 2 Outdoor Air Requirements For Ventilation For Commercial Buildings 3 EPA Report Energy Costs and IAQ Performance

More information

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Indoor air quality Workers and students spend about half their waking hours at work or school. Therefore, maintaining adequate indoor air quality

More information

ASTACEA4 Inspect complex/central air conditioning systems

ASTACEA4 Inspect complex/central air conditioning systems Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air

More information

Indoor Air Quality Issues for Hotels

Indoor Air Quality Issues for Hotels Indoor Air Quality Issues for Hotels Chai chen Chao DEA 670 Spring, 2000 Thermal Control Relative Humidity Winter Temperature Summer Temperature 30% 68.5 F - 76.0 F 74.0 F - 80.0 F 40% 68.5 F - 75.5 F

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

Mechanical and Natural Ventilation

Mechanical and Natural Ventilation BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same

More information

INDOOR AIR QUALITY INTRODUCTION WHAT ARE THE SYMPTOMS OF SICK BUILDING SYNDROME? WHEN DID POOR INDOOR AIR QUALITY BECOME A PROBLEM?

INDOOR AIR QUALITY INTRODUCTION WHAT ARE THE SYMPTOMS OF SICK BUILDING SYNDROME? WHEN DID POOR INDOOR AIR QUALITY BECOME A PROBLEM? INDOOR AIR QUALITY Public Employees Occupational Safety and Health Program Richard J. Codey Acting Governor November, 2004 INTRODUCTION The average person sends approximately 90% of their time indoors.

More information

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings Advanced Energy Design Guide LEED Strategies for Schools and High Performance Buildings Today s Presenters Stephen Koontz, LEED AP Energy Services Leader Tampa Bay Trane Allen Irvine General Sales Manager

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

VENTILATION CHAPTER 4

VENTILATION CHAPTER 4 CHAPTER 4 VENTILATION SECTION 401 GENERAL 401.1 Scope. This chapter shall govern the ventilation of spaces within a building intended to be occupied. This chapter does not govern the requirements for smoke

More information

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE APPLICATION NOTE TI-138 TSI s IAQ-CALC TM Indoor Air Quality Meter and TH-CALC TM Thermohygrometer calculate Percent Outdoor Air (%OA). In order to take

More information

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems APPLICATION GUIDE Moisture Management in Waterborne Climate Systems Contents Introduction 3 WBCS Concept 3 Condensation 4 Moisture Sources in the Space 4 Impact of a High Moisture Load 5 Designing to Manage

More information

LOCATING AIR INTAKES AND EXHAUSTS

LOCATING AIR INTAKES AND EXHAUSTS LOCATING AIR INTAKES AND EXHAUSTS Summary New ASHRAE standards require an investigation of local ambient air quality and documentation of design assumptions and calculations on measures taken to control

More information

Radford University. Indoor Air Quality Management Plan

Radford University. Indoor Air Quality Management Plan Radford University Indoor Air Quality Management Plan Spring 2015 Introduction Concerns with Indoor Air Quality (IAQ) have increased since energy conservation measures were instituted in office buildings

More information

Glossary of HVAC Terms

Glossary of HVAC Terms Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other

More information

Information paper 20. Prepared by: David Clark. book:

Information paper 20. Prepared by: David Clark. book: Information paper 20 Ventilation rates in offices and natural mechanical Prepared by: David Clark A paper referenced in the book: Cundall Johnston & Partners LLP. 2013 Issue 1.0: 29 July 2013 This information

More information

VENTILATION CHAPTER 4

VENTILATION CHAPTER 4 CHAPTER 4 VENTILATION SECTION MC 401 GENERAL 401.1 Scope. This chapter shall govern the ventilation of spaces within a building intended to be occupied. This chapter does not govern the requirements for

More information

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010 EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

CHAPTER 5 Energy Efficient HVAC Design

CHAPTER 5 Energy Efficient HVAC Design CHAPTER 5 Energy 5.1 Guideline 5.2 Mandatory clause 5.3 Technical notes #$$% #$$% #$$& ( ) +, (./ 5.3.1 on optimization of cooling load estimation %0 Table 5.3.1: Inside design conditions for airconditioned

More information

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition IEQ Management Plan GH Phipps Construction Companies 5995 Greenwood Plaza Blvd., Suite 100 Greenwood Village, Colorado 80111-4710 303.571.5377 PHONE www.ghphipps.com Denver Museum of Nature and Science

More information

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP Construction Indoor Air Quality Management Plans for LEED Matt Gregg, PE, LEED AP Agenda What is a Construction IAQ Management Plan? What are the LEED Requirements? What is the Mechanical Contractor s

More information

Venice Library Humidity Study. for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205. Report April 13, 2015

Venice Library Humidity Study. for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205. Report April 13, 2015 for Williams Building Diagnostics, LLC 305 15 th Street West Bradenton, FL 34205 Report April 13, 2015 Moses & Associates, Inc. 2209 NW 40 th Terrace, Suite A Gainesville, FL 32605 FL License EB-0003097

More information

Specification. Indoor Air Quality Management

Specification. Indoor Air Quality Management GREENGUARD Environmental Institute 2211 Newmarket Parkway, Suite 110 Marietta, GA 30067 1.800.427.9681 Specification Indoor Air Quality Management This Master Specification section is intended for use

More information

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality Camfil Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality Most non-practitioners notice the HVAC system when it is too hot, or too cold, or in other ways not working

More information

Indoor Air Quality- What You Need to Know

Indoor Air Quality- What You Need to Know Indoor Air Quality- What You Need to Know Overview Indoor air quality (IAQ) concerns present ever-mounting problems to facility managers and health and safety personnel. From toxic mold to carbon dioxide

More information

VENTILATION CHAPTER 4

VENTILATION CHAPTER 4 CHAPTER 4 VENTILATION SECTION 1 GENERAL 1.1 Scope. This chapter shall govern the ventilation of spaces within a building intended to be occupied. This chapter does not govern the requirements for smoke

More information

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

There are several types of air cleaning devices available, each designed to remove certain types of pollutants. Please Note: EPA neither certifies nor recommends particular brands of home air cleaning devices. While some home air cleaning devices may be useful in some circumstances, EPA makes no broad endorsement

More information

The Finnish Classification of Indoor Environment and Material Emissions

The Finnish Classification of Indoor Environment and Material Emissions The Finnish Classification of Indoor Environment and Material Emissions Jorma Säteri Finnish Society of Indoor Air Quality and Climate, FiSIAQ Finnish Classification of Indoor Environment 2008 An update

More information

PEOSH. Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview. Eric Weren, MSIH

PEOSH. Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview. Eric Weren, MSIH PEOSH Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview Eric Weren, MSIH Public Employees Occupational Safety and Health Unit IAQ Asthma-Friendly

More information

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,

More information

CHAPTER 4 VENTILATION

CHAPTER 4 VENTILATION CHAPTER 4 VENTILATION SECTION 401 GENERAL 401.1 Scope. This chapter, in conjunction with the building code, shall govern the ventilation of spaces within a building intended to be occupied. Mechanical

More information

CHAPTER 4 VENTILATION

CHAPTER 4 VENTILATION CHAPTER 4 VENTILATION SECTION 1 GENERAL 1.1 Scope. This chapter shall govern the ventilation of spaces within a building intended to be occupied. Mechanical exhaust systems, including exhaust systems serving

More information

LEED Breadth. Introduction

LEED Breadth. Introduction LEED Breadth Introduction As of January 2007, the project team has attempted to achieve a total of 50 points under the Leadership in Energy and Environmental Design for New Construction (LEED-NC) rating

More information

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Methods for Effective Room Air Distribution Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Agenda Overview LEED issues and Update Perimeter Acoustics Thermal Comfort IAQ / Standard 62.1 Update

More information

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone. www.titus-hvac.com

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone. www.titus-hvac.com Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION k-12 education Redefine your comfort zone. www.titus-hvac.com woodgrains dual-function energy solutions table of contents The CBAL-24 is

More information

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application APPLICATION GUIDE Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application Section Comparison of Latent Cooling Performance of Introduction Most commercial HVAC systems

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Photo of scott at AC with guages 1 Agenda Day I Refrigerants Introductions Verifying Charge Super Heat Paperwork & Sign-In Subcooling

More information

HVAC Basic Science - System Capacity

HVAC Basic Science - System Capacity HVAC Basic Science - System Capacity Btu/hour, btu/h, b/h, btuh. btu?? 1 MBH = 1000 btu/hour 1 KBH = 1000 btu/hour 1 ton of cooling= 12,000 btu/hour 1 watt = 3.414 btu/hour 1 kilowatt = 1000 watts = 3,414

More information

Integrating Kitchen Exhaust Systems with Building HVAC

Integrating Kitchen Exhaust Systems with Building HVAC Design Guide 3 Improving Commercial Kitchen Ventilation System Performance Integrating Kitchen Exhaust Systems with Building HVAC This design guide provides information that may help achieve optimum performance

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Energy Efficiency in Industrial HVAC Systems

Energy Efficiency in Industrial HVAC Systems Energy Efficiency in Industrial HVAC Systems Heating, ventilation and air conditioning (HVAC) constitutes up to 35 percent of energy used in manufacturing facilities. This fact sheet is geared towards

More information

Educational Performance, Environmental Management, and Cleaning Effectiveness in School Environments

Educational Performance, Environmental Management, and Cleaning Effectiveness in School Environments Educational Performance, Environmental Management, and Cleaning Effectiveness in School Environments By Michael A. Berry, Ph.D. 16 Charrington Place Chapel Hill, NC 27514 Phone: (919) 493-7409 E-mail:

More information

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis Components HVAC General System Selection Life Cycle Cost Analysis Outdoor Air Design Values Indoor Air Design Values Outdoor Air Ventilation Welding Ventilation Temperature Control Systems Ductwork HVAC

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

Comfort Conditioning & Indoor Air Quality

Comfort Conditioning & Indoor Air Quality This article was published in ASHRAE Journal, May 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Reprinted here by permission from ASHRAE at www.newellinstruments.com.

More information

Dedicated Outdoor Air Systems (D.O.A.S.)

Dedicated Outdoor Air Systems (D.O.A.S.) Commercial and Industrial Climate Control Systems Dedicated Outdoor Air Systems (D.O.A.S.) AMDOAS-1 What is it? Why use one? What are my options? Selection considerations Design steps What is it? A separate

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

Indoor air quality monitoring made easy

Indoor air quality monitoring made easy Indoor air quality monitoring made easy with the Fluke 985 Particle Counter Application Note Introduction Energy savings is top of facilities owners agenda. HVAC system tends to be the largest contributor

More information

Preliminary Final Proposal

Preliminary Final Proposal 1 Butler Memorial Hospital New Inpatient Tower Senior Capstone Project Mechanical Option Preliminary Final Proposal Mechanical System Re-design and Breadth Topics Butler Memorial Hospital New Inpatient

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL CONTENTS HOW YOUR SYSTEM WORKS......... 2 COOLING CYCLE....................... 2 HEATING CYCLE (HEAT PUMPS).......... 2 SYSTEM OPERATION................... 2 SETTING THE THERMOSTATS............ 2 THERMOSTATS.....................

More information

INDOOR AIR QUALITY ASSESSMENT INCIDENT RESPONSE. Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts

INDOOR AIR QUALITY ASSESSMENT INCIDENT RESPONSE. Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts INDOOR AIR QUALITY ASSESSMENT INCIDENT RESPONSE Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts Prepared by: Massachusetts Department of Public Health Bureau of Environmental

More information

Fan Applications & System Guide

Fan Applications & System Guide Fan Applications & System Guide Airflow for general ventilation can be calculated by; Area Method Air Change Method Occupancy Method Ventilation Calculation Methods Area Method Derives the ventilation

More information

i n d o o r a i r q u a l i t y I AQ EN 13779:2007 European standard Camfil Farr clean air solutions

i n d o o r a i r q u a l i t y I AQ EN 13779:2007 European standard Camfil Farr clean air solutions i n d o o r a i r q u a l i t y I AQ Camfil Farr Segment brochure EN 13779:2007 European standard Camfil Farr clean air solutions en 13779 environment, air quality and health The industrialised world is

More information

WHOLE-HOUSE VENTILATION SYSTEMS

WHOLE-HOUSE VENTILATION SYSTEMS Technology Fact Sheet WHOLE-HOUSE VENTILATION SYSTEMS Improved control of air quality Buildings for the 21st Century Buildings that are more energy efficient, comfortable, and affordable that s the goal

More information

"An Office Building Occupant's Guide to Indoor Air Quality"

An Office Building Occupant's Guide to Indoor Air Quality "An Office Building Occupant's Guide to Indoor Air Quality" Office of Air and Radiation (OAR) Indoor Environments Division (6609J) Washington, DC 20460 EPA-402-K-97-003, October 1997 Contents A Summary

More information

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries

More information

Old Dominion University Mold Management Plan

Old Dominion University Mold Management Plan OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY 5255 Hampton Blvd. Spong Hall, suite 2501 Norfolk, Virginia 23529 Phone: (757) 683-4495 Fax: (757) 683-6025 Occupational Safety & Health Environmental Health Laboratory

More information

BUILDING PERFORMANCE METRICS

BUILDING PERFORMANCE METRICS BUILDING PERFORMANCE METRICS Hugh Crowther P. Eng. Executive Vice President, Product Management and Technology There is a steady and determined march towards designing better and better performing buildings.

More information

IAQ - indoor ventilation Air contaminants Molds Requirements for growth Health effects Mold prevention - moisture EH&S mold checks & removal

IAQ - indoor ventilation Air contaminants Molds Requirements for growth Health effects Mold prevention - moisture EH&S mold checks & removal Indoor Air Quality & Mold Class Spring 2012 Building Monitors Meeting Presentation Agenda IAQ - indoor ventilation Air contaminants Molds Requirements for growth Health effects Mold prevention - moisture

More information

Walkthrough Inspection Checklist

Walkthrough Inspection Checklist Walkthrough Inspection Checklist This checklist is to aid during an IAQ Walkthrough of the school. The checklist includes considerations both inside and outside the school building: Instructions: 1. Read

More information

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates Causes of High Relative Humidity Inside Air Conditioned Buildings Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates S. FLORIDA AVE. AMBIENT 91 F db / 78 F wb 16,000 HOURS ANNUALLY THAT wb

More information

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates

More information

Ventilation Standard For Health Care Facilities

Ventilation Standard For Health Care Facilities The following article was published in ASHRAE Journal, October 2008. Copyright 2008 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes

More information

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc.

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air. Trevor Wende Vice President, Marketing Advantix Systems, Inc. LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air Trevor Wende Vice President, Marketing Advantix Systems, Inc. 0 Humidity: The Hidden Cost Driver Conventional A/C process Start

More information

ECHO System for Basements

ECHO System for Basements ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton

More information

Key energy-efficient features of your new home

Key energy-efficient features of your new home Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from

More information

HVAC Checklist - Long Form

HVAC Checklist - Long Form HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,

More information

INDOOR AIR QUALITY ASSESSMENT

INDOOR AIR QUALITY ASSESSMENT INDOOR AIR QUALITY ASSESSMENT Massachusetts Criminal Justice Training Council at the Boylston Town Offices Building 221 Main Street Boylston, Massachusetts Prepared by: Massachusetts Department of Public

More information

Causes and Prevention of Symptom Complaints in Office Buildings: Distilling the Experience of Indoor Environment Quality Investigators

Causes and Prevention of Symptom Complaints in Office Buildings: Distilling the Experience of Indoor Environment Quality Investigators Causes and Prevention of Symptom Complaints in Office Buildings: Distilling the Experience of Indoor Environment Quality Investigators Mark J. Mendell, Richard C. Diamond, William J. Fisk Environmental

More information

CHAPTER 4 VENTILATION AIR SUPPLY

CHAPTER 4 VENTILATION AIR SUPPLY CHAPTER 4 VENTILATION AIR SUPPLY 401.0 General. 401.1 Applicability. This chapter contains requirements for ventilation air supply, exhaust, and makeup-air requirements for occupiable spaces within a building.

More information

Hospital Application Guide. Cost-effective climate control for hospitals

Hospital Application Guide. Cost-effective climate control for hospitals Hospital Application Guide Cost-effective climate control for hospitals Munters is the world leader in dehumidification Munters is the largest manufacturer of dehumidifiers in the world. Since developing

More information

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere

What is LEED? Why pursue LEED accreditation? How does LEED accomplish these goals? Sustainable sites Water efficiency Energy and Atmosphere Green AAON for What is LEED? Sustainability and green have recently become terms used within the building industry (and others) to refer to a construction project that has low environmental impact, or

More information

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. QUALITY AIR STARTS HERE. AccuExchange Energy Recovery Ventilator Improve your home s indoor environment by exchanging stale

More information

Pool Dehumidification Basics

Pool Dehumidification Basics Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing

More information

Flexibility, Efficiency In San Antonio Arena

Flexibility, Efficiency In San Antonio Arena 2005, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Reprinted by permission from ASHRAE Journal, (Vol. 47, No. 9, September 2005). This article may not

More information

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Answers to Your Questions from the Webinar

Answers to Your Questions from the Webinar 2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in

More information

Case Studies: Infrared Heating in Industrial Applications

Case Studies: Infrared Heating in Industrial Applications Case Studies: Infrared Heating in Industrial Applications Chao Chen, Puget Sound Energy ABSTRACT Puget Sound Energy (PSE) is a utility which serves more than one million electric customers and over 700,000

More information

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it

More information

Vectren Commercial/Industrial New Construction Incentive Application

Vectren Commercial/Industrial New Construction Incentive Application Vectren Commercial/Industrial New Construction Application Completing and submitting this application is the first step to apply for incentives through Vectren s Commercial/Industrial New Construction

More information

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS VENTILATION RATES AND IAQ IN EUPEAN STANDARDS AND NATIONAL REGULATIONS Nejc Brelih *1, Olli Seppänen 1 1 REHVA Federation of European heating, ventilation and air conditioning associations Rue Washington,

More information

A Breath of Poor Air: Inspecting Indoor Air Quality in the Classroom Ashley Schopieray

A Breath of Poor Air: Inspecting Indoor Air Quality in the Classroom Ashley Schopieray INTRODUCTION A Breath of Poor Air: Inspecting Indoor Air Quality in the Classroom Ashley Schopieray In this lesson students will learn about IAQ (indoor air quality) and the substances that could be polluting

More information

Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes

Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes Liabilities of Vented Crawl Spaces And Their Impacts on Indoor Air Quality in Southeastern U.S. Homes Jonathan Coulter, Bruce Davis, Cyrus Dastur, Melissa Malkin-Weber and Tracy Dixon Advanced Energy,

More information

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air 0 Optimal Air Quality: Critical to Hotels Provides comfortable environment for guests no overcooling Protects building, carpets

More information

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE

DESERT RESEARCH INSTITUTE MOLD ASSESSMENT AND REMEDIATEION PROCEDURE 1.0 Introduction DESERT RESEARCH INSTITUTE This Desert Research Institute (DRI) Mold Assessment and Remediation Procedure was established to assure that consistent and uniform information is provided to

More information

Building and Grounds Maintenance Checklist

Building and Grounds Maintenance Checklist Building and Grounds Maintenance Checklist Name: School: Room or Area: Date Completed: Signature: Instructions 1. Read the IAQ Backgrounder and the Background Information for this checklist. 2. Keep the

More information

SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION SYSTEM CLEANING

SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION SYSTEM CLEANING SECTION 23 01 30.51 HVAC AIR-DISTRIBUTION PART 1 - GENERAL 1.1 SUMMARY A. Section includes cleaning of interior surfaces of HVAC equipment. The HVAC equipment cleaning work includes the following: 1. Air

More information

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Ductless Mini-Split Systems. Comfort... where you need it, when you need it Ductless Mini-Split Systems Comfort... where you need it, when you need it Ductless mini-splits THE COMFORT SOLUTION Ductless mini-split systems are a great solution to a wide variety of installation challenges,

More information

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

Mold and Mildew Mold and mildew can be detected by sight, smell and touch. Mold and Mildew Mold and mildew can be detected by sight, smell and touch. Molds are usually black (not unlike the molds that grow in showers and between grout), green or tan in color, but can be in various

More information