1 Product Introduction MyoMuscle Telemyo DTS-System Telemetry system for EMG and Biomechanical Sensors
2 DTS Device Family 3 major device categories can be used for the Direct Transmission System technology of EMG and mobil biomechanical sensors cdts Clinical System DTS Desk Receiver System DTS Belt Receiver System Designed for clinical use Pre-processed RMS EMG No EMG raw data supported Up to 4 channel EMG Transmission up to 20m Standard lab system Up to 16 channels Unfiltered EMG raw data Analog out to Mocap systems Transmission up to 20m Portable field system Up to 16 channel (raw EMG) Works an additional receiver Long dist. transmission (100m) Optional data logging
3 Full Compatibility to Other MR3 Modules Any DTS transmitter/receiver combination is fully compatible to MR3 s multi-device modules and configurations
4 DTS = Direct Transmission System The DTS System s transmit EMG and sensor data directly from the subject or application site to the receiver/pc Notebook Direct USB Connection to PC Telemetry DTS Desk Receiver or Clinical Receiver
5 Comfortable Use The DTS technology dramatically simplifies the EMG setup and allows for very natural movement Quick and easy electrode attachment Subjects are not influenced by cables Very helpful for small subjects/children Very natural movement
6 EMG Transmission Probes A small amplifier probe is equipped with a WiFi radio module that transmits EMG data in real time up to 15 meter distance EMG transmission probe Size: 3.2 x 2.2 x 1.5 cm Weight: 14 grams Battery: 8 hours Charging: 2.5 hours
7 Flexible Application Concept A short connection cable allows for free electrode selection and free positioning of transmission probes Support of different cable lengths Snap and Pinch connectors Fine Wire Adaptor Reference electrode integrated on backside Fixation with double adhesive tape
8 Flexible Application Concept The connection cable allows for management of pressure areas, skin prolongation, small or thin muscles Skin prolongation at mm. er.spinae Small muscle areas, e.g. m. interossei Thin muscle regions (e.g. m. sternocleidomastoideus) Transmission probe is moved away from pressure area
9 Free EMG-Electrode Selection Almost any electrode type can be used Fine Wire included Single / Dual electrodes Adhesive or Wet Gel Re-usable (Beckmann style) Centralized or decentralized snap Incontinence probes Numerous styles/manufacturers Commercial Fine Wire or needle electrodes Clinical DTS system works with pre-processed RMS EMG, no raw data and fine wire support!
10 Full Research Compatibility Technical recommendations for kinesiological surface/fine wire EMG are covered by the amplifier technology Compatible to ISEK and SENIAM Guidelines International Society of Electrophysiology and Kinesiology Full EMG bandpass 10 to 500 Hz No Notch filtering within EMG band Adjustable to Fine Wire LP Filter at 1500 Hz CMRR > 100 db Baseline noise < 1 uv RMS Input impedance > 100 Mohm Surface Electromyography for the Non-Invasive Assessment of Muscles Clinical DTS system works with pre-processed RMS EMG, no raw data and fine wire support!
11 Superior Signal Quality High quality baseline noise level, typically below 2.5 uv 100 Mean Baseline Noise VMO, uv Mean, uv 50 Clinical DTS system works with pre-processed RMS EMG, no raw data support! 0 s
12 Technical Transmission Details A very sophisticated WiFi transmission concept manages optimal transmission even in difficult WiFi conditions WiFi Delay guaranteed constant Delay adjustable if needed WiFi channel selectable Sync channel available 32 channel option Sampling rate 1500 or 3000 Hz (< 1ms) (36 312ms) (14 channels) (triggered system start) (requires two receivers) (surface or fine wire)
13 Additional Available DTS Sensors Growing list of available mobile biomechanical and physiological sensors Easy to use, pre-calibrated Software Selection Menu
14 3D Acceleration Small, light-weight 3D acceleration sensor in 6 or 16 G measures acceleration, impact/heel strike, vibration and tremor DTS transmission probe Interface cable allows precise sensor positioning Weight: Length: Width: Height: 2.8 g 2.03 cm 1.5 2cm 0.76 cm Acceleration Sensor Machine Vibration/Acceleration Tremor Measurement Tibia bone / gait analysis
15 2D Electrical Goniometer Axis free 2D flexible goniometer for shoulder, spine, elbow, wrist, hip, knee and ankle range of motion measurements Shoulder Knee Spine Goniometer Elbow DTS transmission probe Range: Accuracy: crosstalk: Available: +/- 180 degrees +/- 2 degrees < 5 degrees in 5 sizes
16 2D Inclinometer Small 2D inclination sensor for head, trunk, all extremities and tools, lever arms on machines, tilting platforms Upper Arm Head Thigh DTS probe with built-in Inclinometer Length: 3.05 cm Width: 3.05 cm Height: 3.05 cm Weight: 45.4 g Accuracy: +/- 2 degrees Trunk
17 Mechanical Goniometer 1D mechanical goniometer for elbow, hip, knee and ankle range of motion measurements Elbow DTS probe Gliding mechanism compensates axis migration Goniometer Knee Length: cm Width: cm Height: cm Weight: 34 g Range: +/- 160 Accuracy: 1
18 Local Pressure Thin pressure sensitive sensor allows for local pressure measurements between human surface and interfaces or ground Wrist Heel DTS probe Pressure Sensor Linearity (Error): <± 5% Repeatability: <± 2.5% of full scale Hysteresis: < 4.5% of full scale Response Time: < 5 μsec Sensitivity: 1 lbs, 25 lbs, 100 lbs
19 Hand Grip Strength High precision and research compatible hand grip dynamometer in selectable 5 grip sizes Force Grip Sensor Range: N Sensitivity: 5.56 mv / N 5 grip positions: mm DTS probe
20 Foot Switch System Accurate foot switch system with 2 or 4 sensors per foot, sensitivity adjustment and multi-level signal output DTS Probe Foot switch sensors Alternative foot soles Response time: Output Range: Sensitivity Adjustment: Diameter : ~2 ms 0 to +5 volts 015 to 1.2 kg/cm mm
21 Multi-Sensor Setups Complex multi-sensor setups can be arranged within a few minutes EMG Goniometer Accelerometer Original recording of 100m sprint
22 DTS System in Action Clean, stable signal even in high impact conditions Stable artifact free baseline Highly dynamic jump activity
23 DTS System in Action DTS Telemetry connected to Bertec 3D force plate instrumented treadmill EMG of 4 leg muscles Goniometer signal of knee joint Inclination signal of trunk 3D forces of Bertec treadmill
24 DTS System in Action DTS System used with contact free optical foot switch system Optogait EMG signals of 4 leg muscles 2D Goniometer signal Inclination sensor for arm swing 3D accelerometer tibia bone Virtual foot switch Optogait
25 DTS System in Action DTS system in multi-sensor clinical gait analysis on floor EMG of 4 Leg muscles Goniometer knee joint Inclination arm swing 3D accelerometer tibia bone Multi-level foot switch signal
26 DTS System in Action DTS connected to Bionix 3D trunk training machine Rotation and tilt signal from 3D trainer EMG of trunk muscles
27 DTS System in Action DTS in combination with MyoMotion, MyoPressure-S and MyoVideo Vertical ground reaction force curve 3D angle data from MyoMotion EMG of lower body muscles
28 Clinical DTS System in Action cdts system in combination with MyoVideo and foot switches 2 channels EMG Foot Switch signal Auto-tracked angles from video
29 Clinical DTS System in Action cdts system in combination with MyoMotion: PC workspace evaluation 3D Motion Angles from MyoMotion 2 channels EMG
30 Clinical DTS System in Action cdts system in combination with Moby handheld force sensor Force Signal from Moby 2 channels EMG
31 The Belt Receiver Concept Belt Receiver Concept
32 The Belt Receiver Concept The belt receiver is designed for field studies, mobile use and mainly meant to used so that the subject carries it around (eg. mounted to belt) Synchronized DV Video Mini Receiver Telemetry DTS Belt Receiver
33 Flexible Belt Receiver Design Depending on the experimental design, the DTS Belt receiver can be used in 3 transmission modes Retransmission Portable Belt receiver mode Long distance telemetry (100m) Telemetry Direct USB Connection USB - Desktop mode Direct transmission (15 m) EMG probes on subject Data Logging No PC needed Fully mobile in field studies
34 Belt Receiver: Retransmission Mode Belt receiver is positioned at subject s belt: retransmission to a second receiver connected to PC allows longer distance (up to 100m) Up to 100m! A second USB receiver receives WiFi retransmission data
35 Belt Receiver long distance In Retransmission mode transmission the belt receiver can be used with 3 different USB receiver models USB PC Interface Standard Device MINI Receiver (accessory) with additional 8 AD inputs 2400R Receiver (accessory) with additional 8 AD inputs Analog output for all channels
36 Belt Receiver: Retransmission Mode For long distance transmission up to 100m in sports science, ergonomics and other field study conditions
37 Belt Receiver: USB Connection Mode Belt Receiver can directly be connected to PC: for stationary or laboratory use up to meters transmission distance Up to 10-15m!
38 Belt Receiver: Data Logger Mode WiFi card is replaced with a compact flash card: long duration recording (8 hours) for monitoring and field studies Unlimited in distance Offline! No PC needed!
39 Integration of Other Input Signals The optional Mini Receiver in combination with Belt receiver allows direct connection of 8 stationary input signals from e.g. force plates or isokinetics Stationary biomechanical devices Telemetry System Isokinetics Force Plates WiFi Mini Receiver Analysis PC Analog Input USB Multiple Devices
40 Analog Output Option The optional Analog Output Receiver in combination with belt receiver converts telemetric data to analog output signals that can be directly connected to A/D boards of motion capture systems Motion Capture Systems Telemetry System WiFi Analog Output Receiver Analysis PC Analog Output USB
41 Belt Receiver: Wireless Sync System Both the Mini and Analog Output Receiver are equipped with a wireless sync system to allow shared recording starts MINI Receiver Wireless Sync Signal receiver connected to the portable DTS receiver Any External System with Sync In/Out External Sync In or Out Analog Out Receiver Real time sync (1ms) Sync Port at DTS System
42 Free Educational Booklets Free download at:
EVIDENCE-BASED BIOMECHANICS
EVIDENCE-BASED BIOMECHANICS BEST IN CLASS Technology Software Customer Service EVIDENCE-BASED DIAGNOSTICS EVIDENCE-BASED ADVANTAGE We invite you to experience the highest quality, state-of-the-art measurement
More information1 Synchronising Xsens Systems with Noraxon TeleMyo
1 Synchronising Xsens Systems with Noraxon TeleMyo The steps described below show how to make it possible for Xsens Awinda or Sync Station to send a signal (Awinda / Sync Station is Sync OUT and Noraxon
More informationResearch-Grade Research-Grade. Capture
Research-Grade Research-Grade Motion Motion Capture Capture The System of Choice For Resear systems have earned the reputation as the gold standard for motion capture among research scientists. With unparalleled
More informationHUR Rehab Line H E A L T H & F I T N E S S E Q U I P M E N T
H E A L T H & F I T N E S S E Q U I P M E N T HUR Rehab Line HUR naturally different Contents HUR naturally different HUR SmartCard 1 HUR Rehab Line key to rehabilitation 2 SmartCard FCM Rehab Line computerized
More informationInstruction Manual Service Program ULTRA-PROG-IR
Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationPRODUCT SHEET OUT1 SPECIFICATIONS
OUT SERIES Headphones OUT2 BNC Output Adapter OUT1 High Fidelity Headphones OUT1A Ultra-Wide Frequency Response Headphones OUT3 see Stimulators OUT100 Monaural Headphone 40HP Monaural Headphones OUT101
More informationBuilding a Simulink model for real-time analysis V1.15.00. Copyright g.tec medical engineering GmbH
g.tec medical engineering GmbH Sierningstrasse 14, A-4521 Schiedlberg Austria - Europe Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 office@gtec.at, http://www.gtec.at Building a Simulink model for real-time
More informationMTw Development Kit WIRELESS MOTION TRACKERS
MTw Development Kit WIRELESS MOTION TRACKERS MTw Development Kit incorporates multiple wireless motion trackers (MTw) with the Awinda Station, dedicated software and a set of full body-click-in straps.
More informationShoulders (free weights)
Dumbbell Shoulder Raise Dumbbell Shoulder Raise 1) Lie back onto an incline bench (45 or less) with a DB in each hand. (You may rest each DB on the corresponding thigh.) 2) Start position: Bring the DB
More informationMovement artifacts electrical noise caused by the movement of the sensor surface with respect to the skin surface
BIOHARNESS 42 Aero Camino, Goleta, CA 93117 Tel (805) 685-0066 Fax (805) 685-0067 info@biopac.com www.biopac.com 12.15.08 Field Comparison: Zephyr BioHarness / Polar HR Monitor Introduction The Zephyr
More informationSix-servo Robot Arm. DAGU Hi-Tech Electronic Co., LTD www.arexx.com.cn. Six-servo Robot Arm
Six-servo Robot Arm 1 1, Introduction 1.1, Function Briefing Servo robot, as the name suggests, is the six servo motor-driven robot arm. Since the arm has a few joints, we can imagine, our human arm, in
More informationAuthor: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.
Standards for Reportin ng EMG Data Author: Dr. Roberto Merletti, Politecnico di Torino, Italy The Standards for Reporting EMG Data, written by Dr. Robertoo Merletti, are endorsed by the International Society
More informationTilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology
Tilt switches MEMS technology, one or two axis N3 / N4... + long lifetime and highly reliability due to mechanism-free MEMS technology + combinable output signals + one or two axis measurement + tilt range
More informationProduct Overview 9100D
Product Overview 9100D Portable Shaker Vibration Calibrator The Modal Shop 3149 East Kemper Road Cincinnati, OH 45241 Phone: +1.513.351.9919 Fax: 513.458.2171 info@modalshop.com Brief Overview We've taken
More informationSMART SENSOR COLLECTION
TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8
More informationUser Guide MTD-3. Motion Lab Systems, Inc.
User Guide MTD-3 Motion Lab Systems, Inc. This manual was written by Motion Lab Systems using ComponentOne Doc-To-Help. Updated Tuesday, June 07, 2016 Intended Audience This manual is written to provide
More informationTrigno/Vicon System Integration
Delsys and Vicon Analog Integration Motion capture systems will often have the ability to sample analog data channels as a convenient means for synchronizing external data streams with motion capture data.
More informationLaboratory Construction Guidelines Vicon MX Systems
Laboratory Construction Guidelines Vicon MX Systems These Vicon MX Laboratory Construction Guidelines illustrate how to prepare a life sciences laboratory for installation of your new Vicon MX motion measurement
More informationIntroduction Configuring Your HP Mouse Batteries Replacing the Batteries Mouse Sensor Technology Navigating the HP Mouse Control Center
Introduction Congratulations on your purchase of an HP mouse. This mouse is the latest in a wide range of computer peripherals manufactured by HP. It is designed to provide you with the highest level of
More informationAn internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
More informationMPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
More informationTRIMBLE ATS TOTAL STATION ADVANCED TRACKING SYSTEMS FOR HIGH-PRECISION CONSTRUCTION APPLICATIONS
TRIMBLE ATS TOTAL STATION ADVANCED TRACKING SYSTEMS FOR HIGH-PRECISION CONSTRUCTION APPLICATIONS BY MARTIN WAGENER APPLICATIONS ENGINEER, TRIMBLE EUROPE OVERVIEW Today s construction industry demands more
More informationFUNDAMENTALS OF ROBOTICS
FUNDAMENTALS OF ROBOTICS Lab exercise Stäubli AULINAS Josep (u1043469) GARCIA Frederic (u1038431) Introduction The aim of this tutorial is to give a brief overview on the Stäubli Robot System describing
More informationExercise 1: Knee to Chest. Exercise 2: Pelvic Tilt. Exercise 3: Hip Rolling. Starting Position: Lie on your back on a table or firm surface.
Exercise 1: Knee to Chest Starting Position: Lie on your back on a table or firm surface. Action: Clasp your hands behind the thigh and pull it towards your chest. Keep the opposite leg flat on the surface
More informationUPPER BODY Rowing will strengthen and tone your upper body. Shoulders, back and arms are all involved in the rowing stroke.
THE ULTIMATE WORKOUT It is rare to find an activity that works as many muscle groups through as wide a range of motion as rowing. Knees, hips, arms and shoulders will each see 90 130 degrees of rotation
More informationMoveInspect HF HR. 3D measurement of dynamic processes MEASURE THE ADVANTAGE. MoveInspect TECHNOLOGY
MoveInspect HF HR 3D measurement of dynamic processes MEASURE THE ADVANTAGE MoveInspect TECHNOLOGY MoveInspect HF HR 3D measurement of dynamic processes Areas of application In order to sustain its own
More informationHow To Control Gimbal
Tarot 2-Axis Brushless Gimbal for Gopro User Manual V1.0 1. Introduction Tarot T-2D gimbal is designed for the Gopro Hero3, which is widely used in film, television productions, advertising aerial photography,
More informationProduct Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
More informationConnect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.
17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily
More informationCommunication Packages: Manual Method
Communication Packages: Manual Method Diver USB Reading Unit Handheld connection PC connection Connect your PC, Laptop, or Pocket-PC to a Diver with the Reading Unit to: - Download data - Program settings
More informationGeneral Guidelines. Neck Stretch: Side. Neck Stretch: Forward. Shoulder Rolls. Side Stretch
Stretching Exercises General Guidelines Perform stretching exercises at least 2 3 days per week and preferably more Hold each stretch for 15 20 seconds Relax and breathe normally Stretching is most effective
More informationMH - Gesellschaft für Hardware/Software mbh
E.d.a.s.VX Data acquisition on board road and track vehicles The E.d.a.s.VX System is designed for portable applications running on 12 Volts DC, and is capable of measuring at selectable rates up to 30,000,000
More informationCompressor Supreme Force Feedback User Manual
1. Setting up Compressor Supreme 1. Connect the gear shifter to the back panel of the steering wheel column. 2. Connect the foot pedals to the back panel of the steering wheel column. 3. Connect the A.C.
More informationSPID Azimuth Antenna rotator Type: BIG-RAK/HR
WWW.RFHAMDESIGN.COM SPID Azimuth Antenna rotator Type: BIG-RAK/HR SPID BIG-RAK/HR MD-02 Rotor Controller Type BIG-RAK/HR is a 1 engine rotor system (Azimuth) and delivered including: BIG-RAK/HR rotor 0.2
More informationLower Body Exercise One: Glute Bridge
Lower Body Exercise One: Glute Bridge Lying on your back hands by your side, head on the floor. Position your feet shoulder width apart close to your glutes, feet facing forwards. Place a theraband/mini
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationCurrent Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
More informationAVR 158. Audio/video receiver. Quick-Start Guide ENGLISH
158 Audio/video receiver ENGLISH Quick-Start Guide 158 Introduction, Speaker Placement and Connection Introduction Thank you for choosing a harman kardon product! This quick-start guide contains all the
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationGeoMax GNSS Zenith10 & Zenith20 Series
GeoMax GNSS Zenith10 & Zenith20 Series GeoMax About Us At GeoMax we provide a comprehensive portfolio of integrated solutions by developing, manufacturing and distributing quality construction and surveying
More informationDetermining the Posture, Shape and Mobility of the Spine
Determining the Posture, Shape and Mobility of the Spine The World of Biomechanics Assessment of the Mobility Function Using a special Triple Cervical marker set comprising miniature ultrasound transmitters,
More informationTechnical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
More informationLaboratory Guide. Anatomy and Physiology
Laboratory Guide Anatomy and Physiology TBME04, Fall 2010 Name: Passed: Last updated 2010-08-13 Department of Biomedical Engineering Linköpings Universitet Introduction This laboratory session is intended
More informationiworx Sample Lab Experiment HN-2: Stretch Receptors and Reflexes
Experiment HN-2: Stretch Receptors and Reflexes Exercise 1: Achilles Tendon Reflex Aim: To determine conduction time from tendon tap to response of the gastrocnemius muscle in the Achilles tendon reflex
More informationSAMPLE WORKOUT Full Body
SAMPLE WORKOUT Full Body Perform each exercise: 30 secs each x 2 rounds or 2-3 sets of 8-12 reps Monday & Wednesday or Tuesday & Thursday Standing Squat Muscles: glutes (butt), quadriceps (thigh) Stand
More informationType-D EEG System for Regular EEG Clinic
Type-D EEG System for Regular EEG Clinic Type-D EEG amplifier Specifications 1. For Type-D Amplifier Input channels: 12/24/36/48 Monopolar EEG + 12channels Bipolar EEG+12 channels PSG. Power supply: Internal
More informationUSER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
More informationBidirectional wireless communication using EmbedRF
Bidirectional wireless communication using EmbedRF 1. Tools you will need for this application note... 2 2. Introduction... 3 3. Connect EmbedRF Board to USB Interface Board... 3 4. Install and Run EmbedRF
More informationDAKTON µ BOX MANUAL µbox User Manual 1
µbo User Manual 1 DAKTON µ BO: compact data logger and sensor µ BO is a sensor and a data logger together. It records data processed by DAKTON DASHBOARD with the addition of lateral and longitudinal accelerations.
More informationINFRARED PARTS MANUAL
INFRARED PARTS MANUAL PIR325 FL65 GLOLAB CORPORATION Thank you for buying our Pyroelectric Infrared components. The goal of Glolab is to produce top quality electronic kits, products and components. All
More informationKIN 335 - Biomechanics LAB: Ground Reaction Forces - Linear Kinetics
KIN 335 - Biomechanics LAB: Ground Reaction Forces - Linear Kinetics Reading Assignment: 1) Luhtanen, P. and Komi, P.V. (1978). Segmental contribution to forces in vertical jump. European Journal of Applied
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More information22.302 Experiment 5. Strain Gage Measurements
22.302 Experiment 5 Strain Gage Measurements Introduction The design of components for many engineering systems is based on the application of theoretical models. The accuracy of these models can be verified
More informationInstructor Training Program Levels 1 through 4 Uneven Bars
USA Gymnastics Online: Technique: Uneven Bars Page 1 of 9 Instructor Training Program Levels 1 through 4 Uneven Bars Level 1 - Uneven Bars MOUNT: BACK HIP PULLOVER Grasp bar with hands "shoulder width"
More informationYes No Correction Date. Seated Position Do you know how to adjust your chair? Is your chair adjusted for support & comfort?
UC Davis Health System - Computer Workstation Self Evaluation Assessment Date: Employee Name: Employee ID#: Department: Supervisor: Union Affiliation: Date of Hire (if new hire) Reason for Assessment (circle
More informationTotal Access. Stage 2 IFI accredited equipment. ceptional
Total Access Stage 2 IFI accredited equipment ceptional Features and Benefits Raised iconography on main console controls Colour contrasted belt and deck Laser cut numbers for easy seat positioning Colour
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More informationSE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9
SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9 Learning Goals: At the end of this lab, the student should have basic familiarity with the DataMan
More informationFiber Optic Distributed Temperature Sensor (B-DTS)
Fiber Optic Distributed Temperature Sensor (B-DTS) Low-cost Brillouin BOTDA scattering version For more information about our strain and temperature sensor system and related products, please visit www.ozoptics.com
More informationWahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
More informationEDM Cloud Remote Monitoring Solutions. Crystal Instruments, January 2014
EDM Cloud Remote Monitoring Solutions Crystal Instruments, January 2014 Architecture 1: EDM Cloud runs on the Internet Spiders at multiple locations Client Browser EDM Data Server Ethernet or Wireless
More informationP300 Spelling Device with g.usbamp and Simulink V3.12.03. Copyright 2012 g.tec medical engineering GmbH
g.tec medical engineering GmbH 4521 Schiedlberg, Sierningstrasse 14, Austria Tel.: (43)-7251-22240-0 Fax: (43)-7251-22240-39 office@gtec.at, http://www.gtec.at P300 Spelling Device with g.usbamp and Simulink
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More informationUnderstanding Dynamic Range in Acceleration Measurement Systems. February 2013 By: Bruce Lent
in Acceleration Measurement Systems February 2013 By: Bruce Lent Topics to discuss Definition of dynamic range The effective range Making full use of the high level Using filters to improve dynamic range
More informationWe bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement
MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters
More informationCNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual
LaserProbe4500 CNC-STEP "LaserProbe4500" 3D laser scanning system Instruction manual 2 Hylewicz CNC-Technik Siemensstrasse 13-15 D-47608 Geldern Fon.: +49 (0) 2831 133236 E-Mail: info@cnc-step.com Website:
More informationWireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
More informationMATRIX borehole logging system
MATRIX borehole logging system Combining their long experience in the slimhole logging industry Mount Sopris and ALT have teamed up to develop M A T R I X, providing a single solution to the multiplication
More informationAEO Head Movement Tracker X-GYRO 1000 USER MANUAL(V1.1bata 20091019)
AEO Head Movement Tracker X-GYRO 1000 USER MANUAL(V1.1bata 20091019) Introduction: X-GYRO 1000 is a two axis head tracking system, based on G sensor technique, designed for tracking complicated three-dimensional
More informationNeurodiagnostic Equipment Solutions
Neurodiagnostic Equipment Solutions Neurodiagnostic Equipment Solutions for the Private Practice Quality patient care Reliable information Efficient workflow Dependable service www.natus.com Neurodiagnostic
More informationMANUAL FOR RX700 LR and NR
MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical
More informationibaby Monitor Model: M3s User Manual
ibaby Monitor Model: M3s User Manual Index 1 Introduction...3 1.1 The package contents...3 1.2 Product Features...3 1.3 Product Specifications...4 2 Appearance and Interface...5 2.1 Appearance...5 2.2
More informationProper Workstation Setup
Proper Workstation Setup A Step by Step Guide to help you organize your workstation and reduce the risk of injury Step 1 Review Work Habits Working in a stationary position for long periods will increase
More informationFLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
More informationIRB 2600ID-15/1.85 Simple integration, high performance
Per Lowgren, Product Manager, Medium robots IRB 2600ID-15/1.85 Simple integration, high performance February 9, 2011 Slide 1 Overview of main features General purpose robot for integrated dressing solutions.
More informationContinuous, remote monitoring and logging of electromagnetic fields
MULTI-BAND EMF AREA MONITOR AMB-8057-03/G Continuous, remote monitoring and logging of electromagnetic fields Discrimination of GSM and UMTS contributions to total EMF values Electric field monitoring
More informationERGONOMICS. University at Albany Office of Environmental Health and Safety 2010
ERGONOMICS University at Albany Office of Environmental Health and Safety 2010 WHAT IS ERGONOMICS? From the Greek: ergon work and nomoi natural laws Defined by Webster as: Biotechnology WHAT IS ERGONOMICS?
More informationWind Direction Smart Sensor (S-WDA-M003)
(S-WDA-M003) The Wind Direction smart sensor is designed to work with HOBO Stations. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Station. All sensor parameters
More informationCisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem
Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem The Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem (DPC3010) provides DOCSIS broadband service providers with a cost-effective solution for delivering high-speed
More informationBluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]
Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205] Users Manual Robokits India info@robokits.co.in http://www.robokitsworld.com Page 1 Bluetooth + USB 16 Servo Controller is used to control up to
More information1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
More informationA complete, 24-hour HD video EEG solution
A complete, 24-hour HD video EEG solution PORTABLE & PATIENT FRIENDLY LifeLines ieeg Portable comprises the most critical features requested by leading clinicians and researchers around the globe: Immediate
More informationCornell Digital Reading Room Ergonomics Checklist
Cornell Digital Reading Room Ergonomics Checklist The Cornell Digital Reading Room Ergonomics Checklist is intended as a quick evaluation of the working environment for radiologists who work with digital
More informationStandards for surface electromyography: the European project "Surface EMG for non-invasive assessment of muscles (SENIAM)
Standards for surface electromyography: the European project "Surface EMG for non-invasive assessment of muscles (SENIAM) D.F. Stegeman 1,3, H.J. Hermens 2 1 Institute of Neurology, Department of Clinical
More informationPS 29M DUAL CHANNEL BELTPACK IN METAL CASE
PS 29M DUAL CHANNEL BELTPACK IN METAL CASE USER MANUAL October 2013 This product is designed and manufactured by: ASL Intercom BV Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
More informationThe Universal DAQ Device. Connect and measure immediately!
The Universal DAQ Device. Connect and measure immediately! XXL performance in mini format 8 universal connectors 1) on each QuantumX device suited for most common transducer technologies: 1) See technical
More informationHear The Future...Now! SIEM-2T/SIEM-2R
Hear The Future...Now! SIEM-2T/SIEM-2R UHF PLL Mono In Ear Monitoring System 856 59508-03 ATTENTION Please pay high attention to the following information. The guideline published by Occupational Safety
More informationWATCHWITZ BLAZON WATCHWITZ- BLAZON
WATCHWITZ BLAZON WATCHWITZ- BLAZON WATCHWITZ BLAZON *images for illustration purpose only WATCHWITZ BLAZON 101 > Live Broadcasting Solution WATCHWITZ BLAZON 102 > Live Broadcasting Solution with Professional
More informationBarcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards.
Barcode positioning systems BPS 8, BPS 34/37 Innovations that truly move you forwards. PRODUCT INFORMATION Flexible, tolerant and millimetre precision. The Leuze electronic barcode positioning system.
More informationTargus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.
Targus Wireless RF Mouse Visit our Web site at: www.targus.com Features and specifications are subject to change without notice. 2004 Targus Group International and Targus, Inc.. 400-0111-001B USER S GUIDE
More informationDigital Audio and Data Distribution System
SEICAM 3000 Digital Audio and Data Distribution System SEICAM 3000 Digital Audio and Data Distribution System Data Exchange for Internal / External Communications DDN 3001 front view SEICAM 3000 The Innovation
More informationOuter Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.
1. MODEL: 23CR08FH-50ND 2 Dimension & Weight Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm Baffle Opening 20.1 φ mm Height Refer to drawing Weight 4.0Grams 3 Magnet Materials Rare Earth Size φ 9.5
More informationTHE ULTIMATE WORKOUT JOIN THE ROWING COMMUNITY
A Sport for All People turn to rowing for many reasons: training for a world championship, recovering from injury, cardiac rehabilitation, managing diabetes, keeping fit, losing weight, camaraderie the
More informationTemperature Alert. LAN-based Temperature and Humidity Data Logger
Temperature Alert LAN-based Temperature and Humidity Data Logger LAN-based Temperature and Humidity Monitoring - Supports Simultaneous WiFi and Hardwired Interfaces -20 C to +60 C (-4 F to +140 F) Standard
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationTypes of 3D Scanners and 3D Scanning Technologies.
Types of 3D Scanners and 3D Scanning Technologies. There are many types of 3D scanners and 3D scanning technologies. Some are ideal for short range scanning while others are better suited for mid or long
More information