---- N. Chicago. Mike Massart Lic#

Size: px
Start display at page:

Download "---- N. Chicago. Mike Massart Lic# 450.0000181"

Transcription

1 Scott 4064 N. Lincoln #228 Chicago, IL (773) Property Address: Prepared for: Chicago IL October 7, 2011 Inspector: Mike Massart Lic# Inspection #: CLIENTS REALTOR: SELLERS REALTOR: GENERAL INFORMATION Main Entry Faces: Estimated Age: Unit Type: Stories: Space Below Grade: People Present: East 80+/- Years Two Flat Two Basement & Crawl Client Client's Realtor Time of Inspection: 12:30 Weather: Temp: Soil Condition: Fair 70s Damp o F Unit Occupied: No SERVICES REQUESTED: Building Inspection see also photo supplement Cover... Page #1 Terminology... Page #2 Roof... Page #3 Exterior... Page #4 Grounds... Page #5 Heating / Cooling... Page #6 TABLE OF CONTENTS: Plumbing... Page #7 Electrical... Page #8 Kitchen / Laundry... Page #9 Bathrooms... Page #10 Interior... Page #11 Foundation... Page #12 Summary... pp 13 & 14 Page #1

2 Component is performing its intended function under normal use, though it may show sings of wear. Not Applicable Component is not present at the property, but is not conspicuous by its absence. For instance, "sump pump" may be described "not applicable" in the report of a slab home with no basement. Not Present Component is not present, though it is commonly found in properties of similar type. For example, a sump pump may be described as "not present" in a home with a basement. View Limited Due to finished areas, belongings, roof height/pitch or other conditions, item was not readily accessible. The following "PERSPECTIVE" terms are used to describe component deficiencies. Further Review Safety Concern Client should contact a specialist in specific trade (heating, plumbing, etc.) to evaluate the component(s). Component, or lack thereof, poses a safety or health hazard to occupants or users of the property. Safety Suggestion Voluntary upgrade of a modern safety feature. Client is encouraged to consider the feature, especially if the property is to be used or occupied by children, elderly individuals, etc. This suggestion is NOT intended as a negotiating tool, as many safety upgrades were not available at time of construction. Serious Concern Component has a high probability of incurring substantial expense to repair or replace in the near term. Component is not an easily addressed replacement item, and affects the quality of the building. Health Concern Component shows substantial evidence of environmental or other condition, such as mold, which may be hazardous, especially to sensitive individuals; it is serious enough to warrant immediate attention. Upon being alerted of a "Safety, Serious, or Health" concern, client should contact a specialist in the appropriate trade (heating, electrical, structural/foundation, mold/environmental, etc.). Maintenance Components are worn, older, or lacking paint, caulk, mortar, etc. Though they should be repaired, these components are NOT likely to incur unreasonable expense to repair or replace in the near future. Fair, Marginal Components are worn, older, or otherwise not optimal; however, they do not pose a serious concern, especially given the age and type. These components do NOT require a substantial repair expense. Component shows significant wear/damage, and though present, is not performing as intended, and/or is likely to require substantial expense to repair or replace in the near future. Client should contact a specialist in the related field (licensed plumber, electrical contractor, roofer, etc.) in a timely fashion, and should budget/plan for resolution in the near future. SEE COMMENT suggestion Italicized comments indicate suggestions for the client, and are separate from reported deficiencies. Such items may relate to efficiency, comfort or maintenance, but at times may improve safety. Parts of the report may go beyond description of deficient items; inspector may make suggestions for optimizing the property. Such suggestions are not considered negotiating items. Page #2

3 Roof Type Roof Covering Estimated Age # of Layers Inspection Method Main Roof Flat Modified Bitumen Membrane 8 + Years 4+ Walked Roof Roof Coverings Vents Membrane Roof Vents None Viewed Flat roof surface is uneven, poorly applied, and poorly/partially patched. Air pockets were present below the surface of the modified bitumen roofing. This can lead to cracking over time, and condensation of water vapor. Note water damage to front BR ceiling indicating leakage from poor HVAC unit curb. Flat roofs require periodic inspection/maintenance; water ponding due to obstructions or poor slope should be avoided. **Inspector cannot view/warrant sheathing, underlayment condition without damaging covering. **Roofs are expected to last years in our climate. Refer to licensed roofer for life expectancy comment/estimate. Penetrations serve mechanical systems/appliances. Flashings Chimneys Plumbing Vents Roof cement is used over flashing flanges, these are supposed to be below roof membrane. Steel and iron pipes have separated at kitchen plumbing vent pipe; this may be unused however. Chimney Furnace--Brick Gutters Galvanized Downspouts Run Off Drains Skylights View Limited None ***The chimney review is limited to the visible and/or accessible components only. Serious wear/cracking present at chimney mortar, flues are visible due to gaps in masonry. Metal chimney liner was not installed when the modern 80% efficient furnace was tied to the older masonry chimney. Liners are recommended, and in many cases required by the manufacturer, to insure exhaust flow and prevent damage to masonry. Due to freeze thaw cycles, gutter ice dams can occur in the absence of optimal attic insulation/ventilation. During semiannual cleaning, check gutters for proper slope. Aluminum gutters, though preferred for smaller pitched roofs, are subject to sagging from ice when employed behind flat roofs. Downspout is not diverted away from the home. Unable to determine the condition of the buried drain pipes. Check downspout connections periodically to prevent blockage. Page #3

4 Wall Types Wall Coverings Trim Windows Hose Faucets Electrical Masonry Brick Stone Aluminum Aluminum Caulking Vinyl Lights GFCI Outlets Main Service Wall Coverings Brick Stone Aluminum Fair Marginal Rising damp is indicated by efflorescence (white mineral) and mortar damage at lower masonry. This indicates water moving upward from the foundation. Foundation water should be addressed, as mere patching of mortar, etc. does not address source. Mortar damage is also noted at upper side walls, front portion. Many bricks are cracked and NE corner is bulging, related to sagging/rust of 1st fl. LR window lintel. Alum. siding is dented. Trim Aluminum Caulking See Comment Not Completed Keep grade several inches from bottom of brick or frame wall to limit effect of water, insects. Note gaps betw. brick and alum. siding, at rear. ***Aluminum trim was largely intact; however, aluminum covers the steel window lintels. Gaps around lintels are intended to function as a drainage port for the masonry wall. Doors Front Doorbell, Light Rear Present Caulking will fail in time. Check regularly, remove old cracked caulk prior to reinstallation. To insure safe egress, client is advised against double-keyed deadbolts. Windows Vinyl Screens Glass Block Hose Faucets *** Representative sample of accessible windows operated from the interior. Exact accounting for all storms/screens not performed. Keep hoses off in cold weather to prevent freezing. Shut off any interior valve(s) prior to winter. Despite recent new plumbing, no hose faucet is provided. Electrical Lights GFCI Outlets Main Service Not Present Timer, motion detector, and/or photovoltaic cell actuated lighting was not altered for testing. If not provided, recommend adding GFCI outlets for safety/to prevent extension cord use. ` The elec. service raceway pipe is loose at the N alum. siding, strap is missing. Additional Comments Annual wood destroying pest inspections are recommended. Client should walk around property annually to check the grounds and exterior. Owners of buildings housing small children should pay special attention to lead paint and wood varnishes, especially in old windows; contact lead paint specialist for survey/testing. Page #4

5 PORCHES / PATIOS Location Front Type Stoop Patio Material Concrete Concrete Enclosure Open Open WALKS & STEPS Material Concrete Walks & Steps Walks Steps See Below Concrete has cracked and settled, was poorly patched, slopes to house: at S side. Driveway Not Applicable **A degree of cracking and wear is expected in our climate, especially on concrete which has been excessively salted. Consider de-icing products which are not harmful to concrete. Drainage & Grading Property Drainage Foundation Grading Vegetation Trees Shrubs Fair See Comment suggestion See Comment suggestion Lot drainage is largely flat, which is typical for this type of property. Grading is pitched toward the home at some side areas. Where feasible, maintain a positive slope away from the foundation to direct runoff away. If this is not feasible in areas, consider use of buried drain tiles (PVC pipes or polyethylene hoses in shallow gravel bed) to direct water away from the home. Note large tree w/some marginal limbs, have sewer checked. Keep vegetation at least six inches away from the walls; check tree limbs regularly. Excessive watering next to the foundation can affect wall coverings and lead to seepage. ***Comments pertain to how vegetation affects the building, not the health of the plants. Retaining Walls Not Applicable Porches/Patios Front Stoop Patio FT steps were patched marginally, lack uniform riser height. Garage Garage brickwork marginal but walls overall intact incl. newer vinyl. Roof is new but poorly applied, modified bitumen placed over uneven surface; sagging noted, due to sagging/cracked rafters below; note rotten rafters at the one car bay. Neither bay has GFCI outlet; note smaller than typical dimension for N bay, etc. Page #5

6 Heating: Brand Goodman Fuel Gas-2d fl. Gas-1st fl. Type Mid-Efficient Forced Air Rating 70,000 BTU 70,000 BTU Est. Age New Expected Life Tests Visual Flame Pattern Gas Detector Cooling: Goodman Electric Central A/C 2 1/2 Ton (two units) New Visual Heating Unit Furnace Operation General Condition Limit Controls Wiring Clearances Ventilation Exhaust Vent Thermostat Heat Exchanger Energy Source Gas Shut Off Gas Pipes Electric Shut Off Further Review Further Review Test Limited see roof page Test Limited View Limited Present Present Furnace operated but is unusually noisy, at bsmt. Rooftop unit can't be tested as gas hasn't been completed. **Louvered door (or upper & lower vents) should be maintained to provide ample air. Keep paints, bleach, combustibles, etc. away from gas appliances; recommend annual servicing. Modern heat exchangers are not visible without disassembly. Heat exchangers and exhaust piping should be checked regularly, especially if disturbed by roof work. Distribution Ductwork Blower Fan Registers Additional Components Filter suggestion See Above Some 2nd fl. ductwork has insulation inside, visible at heat registers. Duct poorly located for rear BR. No heating ducts/registers are completed for the finished basement. Annual servicing should include blower. Unable to verify capability of ductwork to uniformly heat or cool each room; consider "balancing" system during servicing. Ductwork should be substantially airtight, incl. filter slot; any insulation should be intact so as not to be respirable. Change filter monthly; keep secured in channel/slot. Pleated/tightly woven filters can reduce air flow compared to inexpensive (blue) filters. If air cleaning is desired add separate air cleaner. Air Cleaner Not Present Cooling Unit Operation General Condition Wiring Not Tested Not Tested see electrical pg. A/C not operated so as not to damage unit: temp. had been <60 degrees within the last 48 hrs. Cleanliness Condensate Drain suggestion suggestion Whenever furnace blower or ducts are dirty, evaporator coil (at furnace) should be serviced. **Check condensate drain line often; maintain flexible wrap close to duct plenum. Drain should terminate above rim of drain or sink; ideally, with trap/air gap near plenum. Keep outside unit clear of vegetatin, maintain 1' of side clearance, 4' clearance above. Page #6

7 Water Supply Supply Pipes Main Water Shut Off Well Pressure Tank Well Pump Public Copper Basement N/A N/A Waste System Public Waste Pipes Cast Iron, Clay Galvanized PVC Waste System Clean Out Gas Pipes Gas Shut Off Basement Black Iron At Meters Basement Water Heater Location Size Type Est. Age Expected Life Richmond Basement 40 Gallon Gas New Water Piping Water Pressure Visible Leaks Service Cross connection Main Shut Off Pipe Insulation Waste Piping Drainage Further Review Visible Leaks None Visible Vents Ejector Pump Not Present Clean Outs Further Review Supports View Limited Gas Piping Comments Piping Type Shut Offs Leaks Detected Supports Further Review None Visible View Limited None Viewed Present View Limited Present View Limited **Additional comments, if applicable, can be found on kitchen, bathroom, foundation pages. Water flow is very low, despite new copper piping in the bldg.; per owner/contractor service to the city shutoff is planned for. However the "Buffalo Box"/blue box city water shutoff, isn't visible in parkway; note large tree nearby. No notch in street & curb found (notch is often made when a service upgrade occurs). Have reviewed by licensed plumbing contractor. As a result of low flow, dishwashers were not tested. **Each shutoff valve not operated, due to potential for leakage, especially on older valves. When opening traditional style valve, back off slightly to prevent it from sticking open. Tubs with 1 1/2" piping often drain somewhat slowly due to rusted galvanized piping. Despite cosmetic upgrades, older steel waste piping remains, viewed at bathroom sinks, note slow tub drainage. Debris hadn't been cleaned out of catch basin and bmst. floor drain. Gurgling at the kitchen sinks is due to defective venting. Flexible under-sink waste piping was improperly used; this indicates less than professional installation, and is more likely to back up. Recommend having smooth piping installed by qualified plumber. **Sub-slab sewer piping not visible; recommend video inspection to determine condition. Two gas leaks were detected: at fittings above each of the meters, marked w/yellow tape. Unable to verify whether gas was shut off before old fireplace valve, 2nd fl. Water Heater Water Heater Tank Water Shut Off Temp Control Burner Safety Relief Valve Exhaust Vent Clearances Drain Valve Present see roof page Not Tested Note poor exhaust venting, open chimney. Page #7

8 Panel Panel Location System Service Entrance Panel Type Main Wire Branch Wiring Each Unit Basement 100 Amp Volt Overhead Circuit Breakers Aluminum Copper Service 100 Amp Volt Metal Conduit Armored Cable Panel Main Panel Main Breaker Branch Breakers Amp/Wire Match Connections Ground/Bonding Panel Cover Grounding Further Review Further Review Safety Concern Safety Concern Serious Concern Further Review Right panel is ~40 years old and substantially rusted, cant be opened due to magnet for access cover. Left panel is new but not professionally installed, no proper water pipe ground is found. 14 gauge wires were too small for 20 amp breakers at several circuits, unable to verify why 15 amp general lighting circuits weren't used--only single pole circuits are 20 amp. Panel is Square D Homeline type, Big Box store product. Anti-oxidant putty was not completed at the aluminum main service wires. This is recommended to prevent loose connections due to oxidation/pitting of aluminum. Outer wire insulation was abraded/damaged, indicating lack of care during wire pulling. This is the case at MANY branch wring areas/most areas where wiring is visible, incl. rooftop HVAC wiring, wires for incomplete bsmt. ceiling lights, etc. Inner wire insulation was intact where visible, but is not visible in the conduit pipes. A degree of "skinning" of the outer clear wire insulation is often encountered, but here the extreme degree indicates wires being damaged from being tugged through conduit/box connections without lubricant. Due to amateur wiring attempts and for safety, this needs thorough repairs incl. wholesale replacement/rewiring of damaged or suspect wires, by qualified licensed electrical contractor. Bonding Further Review Ground Rod Not Present Ground to Water None Viewed Pipe Recommendation Branch Circuit Wiring Conductors Safety Concern Methods See Above Outlets Fixtures Further Review Junction Boxes View Limited Ground Fault Protection Kitchen Bathrooms Garage Exterior Basement Smoke Detectors Smoke Detectors CO Detectors Present Present Not Present Not Present Not Present Safety Concern Safety Concern Water pipes are used for electrical grounding. Potential repair, pipe upgrade, or addition of dielectric unions can interrupt continuity of ground. During timely electrical repairs/upgrades, have ground wire attached to city side of water shutoff; supplemental/driven rod ground is recommended also. Several three prong outlets tested with open ground: one ea. at ea. of the 1st fl. BRs (outlets lack intended safety feature, and conduit lacks metal to metal contact.) Many outlets tested with reversed polarity, several rooms of 2nd fl. Newer BRs were made out of rear enclosed porch, however only one outlet provided: new walls & baseboards, new windows & doors but long walls w/no outlets noted. At E wall of 2nd fl. rear BR, live wires were simply terminated in the wall cavity, w/o a proper box, note wood near the wires. An outlet is inoperative at kit. left, 1st fl. Though ground fault circuit interrupter outlets were not in use at time of construction, GFCI outlets are recommended at damp areas (exterior/garage, kitchen, bath, basement), with the exception of equipment such as refrigerators, sump pumps, etc. Push "test" button monthly. Carbon monoxide detectors are now required by law, within 15' of each sleeping area. Smoke detectors should be within 15' of each BR as well, and at each stairwell. No smoke and CO detectors are found. Page #8

9 Kitchen Walls and Ceiling Floor Doors/Windows see exterior pg. Light Fixtures Outlets GFCI Outlets Cabinets (wood/laminate) Counters see electrical pg. Sink Faucet Water Pipes Waste Pipes see plumbing pg. Heat Source Appliances Gas Range Gas Oven Dishwasher Refrigerator Disposal Range Hood Microwave Oven Laundry Washer Dryer, gas Wall/ceiling/floor Floor Drain Dryer Vent Not Tested Not Tested Not Present Not Completed Not Tested Appliances operated properly unless othewise noted. No warranty is expressed Anti-tip brackets, gas connectors which sense and stop leaks, and other safety upgrades are recommended. Recommend cabinet type screws to insure that cabinets are secured.client should periodically check appliance recalls at Sink & Faucet Washer Hookups Washer Drain Dryer 220 Outlet Dryer Gas Outlet Not Present suggestion Component considered functional notwithstanding minor drips, cosmetic wear. **Washer hoses and dryer gas connectors should be replaced if more than five years old. Modern gas connectors, and metal braided water hoses, have integral shutoff valves to sense and stop leaks; suggest upgrade. Dryer vent and integral dryer lint path should be cleaned regularly. Page #9

10 The property has the following bathrooms - All are reported on this page 1 - Full Bath - (Each Unit) 1 - Full Bath - (Basement) Walls and Ceilings Floors (Ceramic Tile) Doors Light Switches and Fixtures Outlets GFCI Outlets GFCI outlets tripped properly when faulted. each bath Exhaust Fan Sink/Cabinet and Faucet Fans were usually not required if window present. Howver, they are recommended to convey moisture outside. Toilets Tub/Shower and Faucet/Valve Test Limited Tub/Shower Wall Surround **A degree of shrinkage cracking and wear is anticipated in any grouted tile surface. Maintain caulk on surfaces likely to become wet, including cracked inside corner grout lines. Water, Waste and Vent Pipes see plumbing pg. Heat Sources Not Completed Page #10

11 The property has the following interior rooms - All are reported on this page In Each Unit: Stairway Partially Finished Living Room Enclosed Porch Basement Bedrooms Dining Room Hallways Walls and Ceilings (Plaster, Drywall) (Particle Board) Walls and ceilings are in overall serviceable condition. Imperfections like uneven plaster/wall surfaces and stress cracks, etc. are typical to older buildings. Most Areas Floors Floor Coverings (Hardwood Flooring) Ceiling is water damaged, FT BR; rear walls are water damaged, rear BRs. Second Floor First Floor Heating Source Fireplace Light Switches and Fixtures Outlets Ceiling Fans Doors and Windows see heating pg. Not See Comment see electrical pg. see exterior pg. Bare bulb closet fixtures may come in contact with stored items; recommend covered fixtures as safety upgrade. Modern three way switched lighting not completed such as for DR, as part of upgrades. ***Amt. of outlets is inadequate for modern needs. During repairs, recommend adding fixed outlets to limit extension cord use--especially near windows/at likely A/C location(s). Stairs Railings Glass block windows prevent emergency egress from basement BRs. Note that sliding windows, etc. are available for bsmt. window sizes. Note that upgraded burglar bars, which are operable from inside by occupant, are available. Newer rear stairs don't have consistent nosings (treads overlapping risers), lack graspable handrails, guard rail is <36", etc. Enclosed Porch Page #11

12 Foundation Basement Crawlspace Type Poured Concrete Frame Knee Wall Floor Type Concrete Concrete Access Inside Entered Floor Framing Wood Joist Steel Column Access To: Basement Crawlspace Foundation Exposed Walls Floor Floor Framing Subflooring Joists Beams Columns Sill Plates NOTE! Visibility Limited Fair Further Review View Limited Insulation, semi-finished wall and ceiling areas, and/or stored goods, etc. limit foundation visibility, Client should review any concealed areas at walk-through before closing. Basement has finished walls and ceilings. Some cracking is noted at foundation (viewed under stairs), doesn't appear structurally significant, however most is finished. Floor has cracked and settled/heaved. Heaving often indicates water pressure below the slab. Note partial patching, incomplete removal of tile mastic, etc. ***A degree of cracking and sloping is expected at older poured concrete. Joist was cut without a standard header being added, part of rear encl. porch that was repurposed to be a BR. Wood sill plate is rotten as a result of water affecting the rear enclosed porch structure. Water Penetration Basement Further Review Floor Drain see plumbing pg. Sump Pump Not Present Insulation Perimeter Further Review Ventilation Windows see exterior pg. Mold is indicated by spore growth/dark stains at some of the lower foundation walls, incl. older drywall below the newer drywall (under front vestibule). For information on mold removal and prevention, call US EPA hotline at (800) or visit Note musty odor at front, etc. Batt insulation works by trapping air. This is extremely common above grade and is very often used below grade; however batt insulation (as opposed to foam types) is not recommended below grade, as condensation can lead to mold when air is trapped. Exposed Plumbing Supply Pipes Waste Pipes Signs of Leaks Floor Drain Exposed Electrical see electrical pg. general home suggestion **Even in the absence of water penetration, mold can grow in small unventilated areas under porches, near pumps, pipes, meters, etc. Such closets should be ventilated with louvered doors or grilles; dehumidifiers should be used spring through fall. Components are as described on plumbing and electrical pages. "Minor" seepage leads to mold when trapped near paper faced drywall, insulation, etc. During any upgrades, consider products such as fiberglass backed gypsum/drywall, rigid insulation, etc. Wall vapor barriers are NOT recommended as they trap moisture. Page #12

13 This summary page is provided for quicker access to the information within the report. It is not intended as a substitute for reading the inspection report. Items listed below may be discussed further on the corresponding report page. This summary page is intended to highlight the concerns in the report which, in the inspectors opinion, were more than routine maintenance and normal minor concerns. ROOF EXTERIOR GROUNDS GARAGE HEATING PLUMBING ELECTRICAL Flat roof surface is uneven, poorly applied, and poorly/partially patched. Air pockets were present below the surface of the modified bitumen roofing. Note water damage to front BR ceiling indicating leakage from poor HVAC unit curb. Roof cement is used over flashing flanges, these are supposed to be below roof membrane. Steel and iron pipes have separated at kitchen plumbing vent pipe. Serious wear/cracking present at chimney mortar, flues are visible due to gaps in masonry. No metal liner is provided. Downspout is not diverted away from the home. Rising damp is indicated by efflorescence (white mineral) and mortar damage at lower masonry. Mortar damage is also noted at upper side walls, front portion. Many bricks are cracked and NE corner is bulging, related to sagging/rust of 1st fl. LR window lintel. Alum. siding is dented. Despite recent new plumbing, no hose faucet is provided. The elec. service raceway pipe is loose at the N alum. siding, strap is missing. Concrete has cracked and settled, was poorly patched, slopes to house: at S side. FT steps were patched marginally, lack uniform riser height. Garage brickwork marginal but walls overall intact incl. newer vinyl. Roof is new but poorly applied, modified bitumen placed over uneven surface; sagging noted, due to sagging/cracked rafters below; note rotten rafters at the one car bay. Neither bay has GFCI outlet. Furnace operated but is unusually noisy, at bsmt. Rooftop unit can't be tested as gas hasn't been completed. Some 2nd fl. ductwork has insulation inside. No heating ducts/registers are completed for the finished basement. Water flow is very low, despite new copper piping in the bldg.; per owner/contractor service to the city shutoff is planned for. However the "Buffalo Box"/blue box city water shutoff, isn't visible in parkway. Have reviewed by licensed plumbing contractor. Despite cosmetic upgrades, older steel waste piping remains, viewed at bathroom sinks. Debris hadn't been cleaned out of catch basin and bmst. floor drain. Gurgling at the kitchen sinks is due to defective venting. Two gas leaks were detected: at fittings above each of the meters, marked w/yellow tape. Unable to verify whether gas was shut off before old fireplace valve, 2nd fl. Note poor water heater exhaust venting, open chimney. Right panel is ~40 years old and substantially rusted, cant be opened due to magnet for access cover. Left panel is new but not professionally installed.14 gauge wires were too small for 20 amp breakers at several circuits, unable to verify why 15 amp general lighting circuits weren't used--only single pole circuits are 20 amp. Panel is Square D Homeline type, Big Box store product. Several three prong outlets tested with open ground: one ea. at ea. of the 1st fl. BRs. Many outlets tested with reversed polarity, several rooms of 2nd fl. Newer BRs were made out of rear enclosed porch, however only one outlet provided: new walls & baseboards, new windows & doors but long walls w/no outlets noted. At E wall of 2nd fl. rear BR, live wires were simply terminated in the wall cavity, w/o a proper box, note wood near the wires. Outer wire insulation was abraded/damaged, indicating lack of care during wire pulling. This is the case at MANY branch wring areas/most areas where wiring is visible, incl. rooftop, bsmt. ceiling lights, etc. Extreme degree of abrasion indicates wires being damaged from being tugged through conduit/box connections without lubricant. Due to amateur wiring attempts and for safety, this needs thorough repairs incl. wholesale replacement/rewiring of damaged or suspect wires, by qualified licensed electrical contractor. Carbon monoxide and smoke detectors not provided. pp 13 & 14

14 This summary page is provided for quicker access to the information within the report. It is not intended as a substitute for reading the inspection report. Items listed below may be discussed further on the corresponding report page. KITCHEN BATHROOMS INTERIOR Ceiling is water damaged, FT BR; rear walls are water damaged, rear BRs. Newer rear stairs don't have consistent nosings (treads overlapping risers), lack graspable handrails, guard rail is <36", etc. FOUNDATION Floor has cracked and settled/heaved. Heaving often indicates water pressure below the slab. Note partial patching, incomplete removal of tile mastic, etc. Joist was cut without a standard header being added, part of rear encl. porch. Wood sill plate is rotten as a result of water affecting the rear enclosed porch structure. Mold is indicated by spore growth/dark stains at some of the lower foundation walls, incl. under front vestibule. pp 13 & 14

15 PROPERTY INSPECTIONS INSPECTION PHOTO SUPPLEMENT RE: report #8491 Scope: photos of a sample of reported conditions; refer to narrative report ROOF Chimney; broken kitchen vent stack; patching attempts 1

16 Poor curb for HVAC unit Note old built up tar & gravel roof layers below this roof, poor flashing EXTERIOR Poor patch at steps; rust jacking due to sagging/rusting 1 st fl. LR lintel 2

17 rising damp, S gangway Garage roof new but poor, open clay coping; cracked & rotten rafters 3

18 MECHANICAL Abraded wire insulation, rooftop HVAC and basement; wires in wall opening, 2 nd fl. rear BR; open chimney Poor water flow, flexible new tubing, old steel waste piping; note old gas pipe 4

19 INTERIOR rear BR otherwise new/created out of encl. porch, but only one outlet/some long walls lack outlets Water stains also at this area; note very narrow closet FOUNDATION/BASEMENT Gas leaks found at bsmt. front; debris in catch basin, rear 5

20 Rotted sill plate, unsupported joist, rear; mold at front/s area under stairs 6

8** W. Any Street Chicago. Mike Massart Lic# 450.0000181

8** W. Any Street Chicago. Mike Massart Lic# 450.0000181 Scott 4064 N. Lincoln #228 Chicago, IL 60618 (773) 635-7873 202744 Property Address: Prepared for: Chicago IL May 6, 2007 Inspector: Mike Massart Lic# 450.0000181 Inspection #: CLIENTS REALTOR: SELLERS

More information

www.citiesinspection.com October 5, 2015 Dear Client,

www.citiesinspection.com October 5, 2015 Dear Client, www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.

More information

HOME INSPECTION CHECKLIST

HOME INSPECTION CHECKLIST CLOSING.COM LEARNING CENTER HOME INSPECTION CHECKLIST CONTENTS Attic 1 Balconies 1 Basement 1 Bathroom 2 Ceiling, Floors and Walls 2 Crawlspace 3 Decks and Porches 3 Doors and Windows 4 Drainage 4 Driveways

More information

Vision Home Inspection

Vision Home Inspection Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the

More information

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111

A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 A.C.E. Home Inspection Service www.acehomeweb.com St. Peters, MO 63376 (636) 978-9111 Inspector Name: Tim Knight, ASHI Member 202490 Inspection No: 12121212 Inspection Date: 1/1/2012 Client: Address: John

More information

PROPERTY INSPECTION REPORT Property Address:

PROPERTY INSPECTION REPORT Property Address: Scott Certified Member P. O. Box 9007 Indianapolis, IN 690-007 (7)-750-60 Fax: 7-876-8 PROPERTY INSPECTION REPORT Property Address: Prepared for: Inspection Inspector: Lou Buehler Inspection #: BUYERS

More information

Total Home Inspection Checklist

Total Home Inspection Checklist Total Home Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

Self-Home Inspection Checklist

Self-Home Inspection Checklist To be used as a first home visit for note taking. Visit www.homeinspectiondirect.com for more tips and information about buying a home and hiring a home inspector. This form in no way replaces a professional

More information

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois Accurate Home Inspection of Illinois 815-260-1727 1213 Norley st. Joliet, illinois 60435 aaccurate1@yahoo.com We Inspect to Protect!!! Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave.,

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT (850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304

More information

Inspection Tech. (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg

Inspection Tech. (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg Inspection Tech (330) 310-6559 http://www.inspectiontech.us a_westerburg@inspectiontech.us Inspected By: Aaron Westerburg Inspection Tech Home Inspection Report Prepared For: Mr. & Mrs. Homebuyer Property

More information

Home Inspection Report

Home Inspection Report 4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 tripleainspections@gmail.com Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:

More information

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide A comfortable house is a great source of happiness. - Sydney Smith Home Maintenance Guide HOME GUIDE By conducting regular maintenance checks, you can prevent small inexpensive repairs from becoming more

More information

Georgia Home Inspection Services

Georgia Home Inspection Services Cover Page Property Inspection Report My street, Anytown GA, 30000 Inspection prepared for: John Doe Inspection Date: 7/18/2011 Time: 5pm Age: 25+ Size: >1500 Weather: Clear This ranch style home is in

More information

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000

Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000 Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,

More information

Vari Inspection Services

Vari Inspection Services Cover Page Vari Inspection Services Property Inspection Report Inspection prepared for: Sample Real Estate Agent: None - Date of Inspection: 5/13/2015 Inspector: Tony Vari License # HI8047 23110 STRD 54

More information

Inspecting to a higher standard.

Inspecting to a higher standard. Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com

More information

159 Morningside Avenue, Toronto

159 Morningside Avenue, Toronto 159 Morningside Avenue, Toronto Inspection Report February 6, 2013 159 Morningside Avenue, Toronto Inspection Report Overall Condition: This 60±-year-old home was extensively renovated and extended in

More information

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM

Printed Monday, August 27, 2007 Inspected By: Michelle Teague. Client Information: Inspection, Condo City Lane Chicago, IL. Inspected 8/22/07 8:00 AM Pa g e 1 o f 1 5 All About Homes, LLC Michelle M. Teague Owner 312-371-7414 Phone 773-508-6209 Fax www.michelleinspects.com michelle@michelleinspects.com 1725 W. Granville Ave. Chicago, IL 60660 Printed

More information

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Inspection Report Atlanta Strip Mall Commercial Building Property Address: Page 1 of 25 Inspection Report Atlanta Strip Mall Property Address: Smyrna GA 30082 Page 2 of 25 South East Building Consultants Ray Thoroman Serving the entire State of Georgia 6 678-410-3005 Page 3 of

More information

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C. CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front

More information

Orlando Home Inspection Services

Orlando Home Inspection Services PLEASE NOTE: Orlando Home Inspection Services Serving Central Florida since 1999 P O Box 915451, Longwood, Florida, 32791-5451 Phone: (321) 228-2493 Fax: (407) 374-8505 Web: http://www.orlando-home-inspections.com

More information

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com

Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Crawford Inspection Services C.C.B. # 76914 www.crawfordinspections.com Portland Area PO Box 665 West Linn, OR 97068 Ph: (503) 650-6957 Salem Area 5434 River Rd. N; #192 Keizer, OR 97303 Ph: (503) 362-5809

More information

SWF Home Inspections

SWF Home Inspections Cover Page SWF Home Inspections Property Inspection Report Inspection prepared for: Mr & Mrs Home Buyer Real Estate Agent: My Favorite Agent - Date of Inspection: 7/4/2013 Age of Home: 2004 Size: 1568

More information

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES CHRIS CURLES and ASSOCIATES INSPECTION SERVICES Inc. Chris Curles, President www.homeinspectionsatlanta.com chriscurl@comcast.net Office: 770-493-0227 Professional Member Of: GAHI # 93006 ASHI # 211725

More information

Structure Survey Findings:

Structure Survey Findings: Structure Survey Findings: Visible portions of the following were observed: foundations; structure to walls, columns, floors, roofs, overhang posts, and columns; attached or firmly abutting decks, balconies,

More information

Home Inspection Report

Home Inspection Report Report# 21009 Page 1 of 24 Home Inspection Report Property Address: 123 Maple Lane, St. Augustine, FL 32092 Prepared For: Mr. Smith Prepared By: EDGE Inspections www.edgeinspections.com PO Box 601055 Jacksonville,

More information

COMPREHENSIVE PROPERTY INSPECTIONS

COMPREHENSIVE PROPERTY INSPECTIONS COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited

More information

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Page 1 of 22 Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado 80212 303-885-1288 Printed Friday, January 16, 2015 Inspected By: Dale Gibbs Referral Information Joe Agent Client Information:

More information

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections

Inspection Report. Prepared For: Sampath Sample. Property Address: 12712 Waterside Drive. Alpharetta, GA 30004. Atlanta Home Inspections Page 1 of 37 Inspection Report Prepared For: Sampath Sample Property Address: Alpharetta, GA 30004 Atlanta Home Inspections Matthew A Thoroman 6625 Hwy. 53 E. Ste. 410-151 Dawsonville Ga 30534 (678)-410-8062

More information

19 Ellis Park Road, Toronto

19 Ellis Park Road, Toronto 19 Ellis Park Road, Toronto Inspection Report September 9, 2015 19 Ellis Park Road, Toronto Inspection Report Overall Condition: This is a solidly built older double-brick home that is in fairly original

More information

Inspection Item COMMENTS

Inspection Item COMMENTS APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:

More information

A and S Property Inspector

A and S Property Inspector Cover Page A and S Property Inspector Property Inspection Report Inspection prepared for: xxxxx xxxxx Real Estate Agent:.. - Date of Inspection: 8/25/2014 Time: 10am Age of Home: 1999 Size: 1841 Weather:

More information

Inspecton Report. Property Address:

Inspecton Report. Property Address: Inspecton Report Provided by: National Home Inspections Inspector: Bob Smith 456 S Main Denver, CO 46312 (645) 423-3242 bob@nationalhomeinspections.com www.nationalhomeservices.com Property Address: 873

More information

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: 1860. Inspection Date: Saturday, February XX, XXXX SUMMARY REPORT Report Number: 1860 Inspection Date: Saturday, February XX, XXXX Property Address: XX XXXXX XXX Toronto, ON XXX XZX Client Name: Xxxx Xxxxxxxxxxxxx Prepared by: Andrew Marioselva BSc,CHI

More information

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist

More information

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire.

Recommend that the dryer vent be cleaned annually to remove lint that may cause a fire. Attached Garage Garage-house door isn't auto-closing. Recommend installing hinges with springs or an automatic door closing device so door closes automatically to prevent vehicle fumes from entering building.

More information

South Carolina Home Inspector Standards of Practice

South Carolina Home Inspector Standards of Practice South Carolina Home Inspector Standards of Practice The following Standards provide guidelines for the Residential Home Inspector and outline what the Residential Home Inspector should observe, identify,

More information

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen May 2008 Wisconsin Area PO BOX 115 Lake Geneva, WI 53147 CELL (414) 550-4765 Home Performance with ENERGY STAR Evaluation Report Customer

More information

Simplify. Homeownership

Simplify. Homeownership Simplify Homeownership Home Pulse An Innovative Program To Maintain Your Home. The Home Pulse Preventive Maintenance Plan will keep your home looking great, dramatically slow the deterioration process

More information

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas 5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 harris31@sbcglobal.net INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction

More information

Peak Home Inspection Services

Peak Home Inspection Services 09:48 July 28, 2009 Page 1 of 13 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection A Acceptable Functional with no

More information

Estimating Database Checklist

Estimating Database Checklist Estimating Database Checklist If you are creating a new estimating database for projects, the following list offers a thorough listing of Main and Sub Categories. You can also use it as a checklist to

More information

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)355-1748 Inspection Report provided by: Delaware Property Inspection Inspector: Richard Hiddemen (302)355-1748 ASHI # 243377 DPR #H4-0000018 DDA #06-444 Delaware 1992105842 Wilmington #03857 New Castle #2010-845

More information

ink Home Inspections, LLC

ink Home Inspections, LLC Cover Page ink Home Inspections, LLC Property Inspection Report 98156 Inspection prepared for: Carey Smith Real Estate Agent: agent 007 - ACME Homes Date of Inspection: 9/14/2013 Time: 9:00am - 12:00pm

More information

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668 Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:

More information

Building Condition Assessment Report

Building Condition Assessment Report Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.

More information

Home Inspection Report

Home Inspection Report 123 Somewhere Street Somewhere, US 12345 Home Inspection Report Yourtown, US 12345 Page 1 of 20 Marginal Summary This summary is not the entire report. The complete report may include additional information

More information

If there are any further questions with regards to the report or inspection, please call.

If there are any further questions with regards to the report or inspection, please call. National Home Inspection Ltd. 1055 Woodbine Avenue Toronto, Ontario M4C 4C2 TEL: (416) 467-7809 FAX: (416) 429-5443 April 15, 2014 SUMMARY INSPECTION REPORT PROPERTY: 75 Fairlawn Avenue, Toronto, Ontario

More information

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010 Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # 3380 000373, expires 1/2010 Tel: (804) 378-0861 terry@prospectpropertiesva.com Inspection

More information

Building Condition Assessment Report

Building Condition Assessment Report C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Cincinnati, Ohio 45000 Prepared for: Dean Murphy Prepared by: BEDROCK ENTERPRISES, INC. 4060 Simca Lane Cincinnati, OH 45211 20:13 July 07, 2008 Page 1 of 18 Definitions NOTE: All

More information

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS Insurance Inspection Report 1234 Main Street Tallahassee, Florida Report Prepared For: Charles Smith Report Prepared

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 555 Wind Way, Fake City, OR 54645 Inspection Date: Monday May 12, 2014 Prepared For: John Doe Prepared By: House to Home 3468 N. Bartlett Ave Milwaukee, WI 53211 262-754-5973 christopher@ahit.com

More information

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL 32204. South East Building Consultants

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL 32204. South East Building Consultants Page 1 of 53 Inspection Report Jacksonville Property Address: Jacksonville FL 32204 South East Building Consultants Ray Thoroman Inspecting Jacksonville FL and entire South East Page 2 of 53 Table of Contents

More information

Home Inspection Report

Home Inspection Report 123 Somewhere Street Somewhere, US 12345 Home Inspection Report Yourtown, US 12345 Page 1 of 24 Table of Contents Invoice 2 Definitions 3 General Information 3 Lots and Grounds 4 Exterior 5 Roof 6 Garage/Carport

More information

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check #1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility

More information

Pre-Drywall Inspection Report

Pre-Drywall Inspection Report SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion

More information

INSPECTION CONNECTION, INC.

INSPECTION CONNECTION, INC. INSPECTION CONNECTION, INC. Professional Real Estate Inspections and Consulting Services 2932 West 100 th Street Evergreen Park, IL 60805 708-346-0708 800-573-1113 mike@inspection2020.com 312-429-1230

More information

Strickland Home Inspections, LLC 10200 38th Ct N Plymouth, MN 55441. Inspection Report. xxxx St Clair Ave St Paul, MN 55105

Strickland Home Inspections, LLC 10200 38th Ct N Plymouth, MN 55441. Inspection Report. xxxx St Clair Ave St Paul, MN 55105 10200 38th Ct N Plymouth, MN 55441 Inspection Report xxxx St Clair Ave St Paul, MN 55105 Page 1 of 27 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior Surface and Components

More information

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: 61-30.801 Standards of Practice, General. (1) Home inspections performed to these Standards of Practice are intended to provide the client with information

More information

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division

Code Enforcement Inspection Manual. City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division Code Enforcement Inspection Manual City of Virginia Beach Department of Housing and Neighborhood Preservation Code Enforcement Division LIVING ROOM 304.15 EXTERIOR DOOR(S) Check door(s) and trim for condition,

More information

Integrating Healthy Housing Considerations into Weatherization Inspections. Jim LaRue

Integrating Healthy Housing Considerations into Weatherization Inspections. Jim LaRue Cleveland Cuyahoga County Healthy House Project Training Integrating Healthy Housing Considerations into Weatherization Inspections Jim LaRue Joint inspections for housing health hazards Weatherization

More information

Inspection Report. Mr. Happy 2 flat owner. Property Address: Focal Point Home Inspection Ltd.

Inspection Report. Mr. Happy 2 flat owner. Property Address: Focal Point Home Inspection Ltd. Page 1 of 35 Inspection Report Mr. Happy Property Address: Joseph Poelsterl 450.010220 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Page 2 of 35 Table of Contents Cover Page Table of Contents

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792

More information

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066 Page 1 of 58 Inspection Report Prepared For: Atlanta Commercial Customer Property Address: Building 5 Marietta, GA 30066 Superior Home Inspections Ray Thoroman 8070 Ivy Shaw Dr. Gainesville,GA 30506 678-410-3005

More information

API America s Property Inspections

API America s Property Inspections API America s Property Inspections DESCRIPTION OF HOUSE: Ranch CONCLUSION Mr. xxxx INSPECTION ADDRESS 00/00/2011 APPROXIMATE AGE: 10 years (according to the homeowner) TYPE OF BASIC CONSTRUCTION: Poured

More information

BUILDING INSPECTION REPORT

BUILDING INSPECTION REPORT PROPERTY INSPECTED: BUILDING INSPECTION REPORT REPORT NO: 5657 CLIENT: INSPECTORS: Malcolm Whipkey / Clyde Volk APPROX. AGE OF BUILDING: 50+ Years BUILDING DESIGN: Commercial Building with Four (4) Office

More information

City of St. Charles Basement Finish or Remodel

City of St. Charles Basement Finish or Remodel City of St. Charles Basement Finish or Remodel Building & Code Enforcement Division 2 East Main Street St. Charles IL 60174 630.377.4406 (Office) 630.443.4638 (Fax) http://www.stcharlesil.gov Please direct

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

GENERAL WIRING RULES FOR HOUSES

GENERAL WIRING RULES FOR HOUSES GENERAL WIRING RULES FOR HOUSES 1. Romex has to be installed in drilled holes in joists or studs even above suspended ceilings - No stapling to bottom edges of joists or studs. You may staple wire to flat

More information

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection! NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection! Current Owner Name: Mpls City Property Atn Cped (p Contact: Mpls City Property Atn Cped (p Business/Relationship: Owner Address:

More information

Home Inspection Report

Home Inspection Report Home Inspection Report Report Number: 144 For The Property Located On: 123 Any Street 27587 Prepared For Exclusive Use By: Mr. Sample N/A,,, Report Prepared By: Edward Carapezza; License No.: 3447 Inspector

More information

Home Maintenance Checklist

Home Maintenance Checklist Regular maintenance keeps your home functioning efficiently and safely and helps protect its value. We're happy to offer this checklist of ongoing and seasonal maintenance steps to help you safeguard your

More information

I NI NP R Inspected Items

I NI NP R Inspected Items 6/ /07 The Inspection of the property listed above must be performed in compliance with the rules of TREC. The inspection is of conditions which are present and visible at the time of the inspection, and

More information

ROCK-SOLID Inspections

ROCK-SOLID Inspections Home Inspection Services 123 S. Main Street Chicago IL 60000 Inspection prepared for: Joe Citizen Inspection Date: 2-28-2006 Time: 4:30pm Weather: Clear 30 degrees Inspector: Rich Rochowicz 3642 W. 113th

More information

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick Prepared by: The Inspection Guys www.inspectionguys.com 16 Mt. Bethel Road, Suite 171 Warren, NJ 07059 800-903-0670 Fax: 732-238-7092

More information

Property Inspection Report

Property Inspection Report Property Inspection Report 1234 Bear St., Denver, CO 80223 Prepared For: John Smith Inspection Date: 12/11/2015 Prepared By: Bill Heine, Certified Professional Inspector ResInspect, LLC 303-359-7573 Email:

More information

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN 12345. 1234 USA Drive. Morris Home Inspection Group, LLC

Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN 12345. 1234 USA Drive. Morris Home Inspection Group, LLC Inspection Report Mr. Sample Sample Property Address: 1234 USA Drive Indianapolis IN 12345 1234 USA Drive Morris Home Inspection Group, LLC Cedric Morris HI01200039 Fishers, IN 46037 317-550-6281 Table

More information

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396 BUILDING ANALYSIS REPORT July 25, 2014 John Doe 1234 Smith Road Atlanta, Georgia 30396 Agent: Ausker and Barbara Morris AT Morris Realty Group, Inc. 3162 Johnson Ferry Road, Suite 260-25 Marietta, Georgia

More information

Home Inspection Report

Home Inspection Report Home Inspection Report?? Tremont Ave, Westfield, NJ 07090 Inspection Date: Tuesday March 31, 2015 Prepared For: Tim Jones Prepared By: Cornerstone Home Inspection 9736504151 Report Number: 33115 Inspector:

More information

License Requirements for Persons Engaging in the Business of Inspection Practice:

License Requirements for Persons Engaging in the Business of Inspection Practice: SC Standards of Practice SOUTH CAROLINA RESIDENTIAL BUILDERS COMMISSION HOME INSPECTOR STANDARDS OF PRACTICE Adopted by the Residential Builders Commission May 13, 1998 PURPOSE: The purpose of a residential

More information

Home Management Checklist: Spring

Home Management Checklist: Spring Home Management Checklist: Spring HVAC System Attic Plumbing and Electrical Service air conditioning unit (Ventilation inspected as part of service call). Ensure gutters are discharging water away from

More information

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10 PROPERTY DESCRIPTION PROPERTY INSPECTED: INSPECTION ADDRESS: 4722 Baltimore Avenue

More information

2. What building projects are exempted? (permit not required)

2. What building projects are exempted? (permit not required) BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1234 School House Road Yourtown, US 12345 Prepared for: Bob Smith Prepared by: Your Company Name Here 9600 Colerain Ave Suite 110 Cincinnati, OH 45215 17:26 August 02, 2006 Page

More information

INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

INVOICE. DATE: May 11, 2005. DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. INVOICE DATE: May 11, 2005 CLIENT: The Buyer DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl. TOTAL FEE: $ See Schedule Tom Villani Hallmark Inspection

More information

Real Estate Inspection Report

Real Estate Inspection Report 1010 22nd Ave N Naples, Florida 34103 Real Estate Inspection Report 470 Golden Gate Blvd W Naples, Florida 34120 Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior

More information

Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102

Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102 Page 1 of 26 Home Systems Data Inc. 7305 E. Peakview Ave. Centennial CO. 80111 303-773-6102 Printed Friday, January 14, 2011 Inspected By: None None Realtor NONE Client Information: Name, Your 123 Street

More information

RRIO Checklist. Use of checklist: Definitions: Limitations

RRIO Checklist. Use of checklist: Definitions: Limitations CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units

More information

Whole House Inspection Report

Whole House Inspection Report Whole House Inspection Report Exclusively For: [Name] [Address] [City, State Zip] Office: 816-746-0003 800-752-0003 April 11, 2006 [Name] [Address] Overland Park KS 66223 REF: 0019724 [Inspection Address]

More information

HOME INSPECTION REPORT

HOME INSPECTION REPORT Edgewood Home Inspections, Inc. 407 W. Smith Valley Rd. #1032 Greenwood, IN 46142 (317) 833-6048 HOME INSPECTION REPORT Indianapolis IN 46000 Inspector's Name: License Number: Scott Kissel HI00800073 TABLE

More information

Home. Safe. Home. home inspection report

Home. Safe. Home. home inspection report home inspection report Home. Safe. Home. Each office is independently owned and operated. 2013 The HomeTeam Inspection Service, Inc. All rights reserved. What is a home inspection? The purpose of a home

More information

Home Inspection Report

Home Inspection Report Home Inspection Report 1234 School House Road Yourtown, US 12345 Prepared for: Bob Smith Prepared by: Your Company Name Here 9600 Colerain Ave Suite 110 Cincinnati, OH 45215 17:22 August 02, 2006 Page

More information

How To Insure Against Problems With Your Home Warranty

How To Insure Against Problems With Your Home Warranty Subcontractor Warranty Policy ALL WARRANTY REQUESTS MUST BE IN WRITING. Please submit all warranty requests online by visiting: www.rigginscustomhomes.com/customerservice.html Please fill out the form

More information

Propery Inspection Report

Propery Inspection Report Propery Inspection Report Cover Page,, Ok Inspection prepared for: Date of Inspection: 9/28/2014 Time: 8:30 AM Age of Home: 2011 MOL Weather: Clear 62 degrees Inspector: License #130 5400 Hwy 177, Marland,

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing 1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize

More information

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space)

COST OF WORK FORM. Abbreviations: ea = each, LF = linear feet, SF = square feet, HSF = square feet of living area (including garage conversion space) COST OF WORK FORM All costs shown are estimates using base grade materials, taxes, and labor. For houses where a higher quality is indicated, the costs should be increased for work requiring upgraded materials.

More information

Attachment #23 Health Safety Table. Client Education Inform issue and document. How to clean & maintain gutters. How to adjust sprinklers

Attachment #23 Health Safety Table. Client Education Inform issue and document. How to clean & maintain gutters. How to adjust sprinklers Exterior Visual Health & Safety Issue Allowable Action Site Drainage Exterior grade does not slope 2% within the first 10' Site drainage causing bulk moisture in crawl space or basement Repairs to existing

More information