Expert Integrated Systems. Technischer Überblick
|
|
- Charles Wilkerson
- 8 years ago
- Views:
Transcription
1 Expert Integrated Systems Technischer Überblick
2 Test : PureFlex Technical Support V1 Teil I/II 1
3 Test : PureFlex Technical Support V1 Teil II/II 2
4 Die Schaffung eines integrierten Systems adressiert die wachsenden IT-Herausforderungen. Networking Storage Virtualization Servers Management 3
5 Expert Integrated Systems Eine voll integrierte und offene Infrastruktur mit einem single pane of glass Systems Management. Flexible und offene Umgebung AIX i Linux Windows PowerVM KVM VMware HyperV Integrierte Infrastruktur Integrated, Flexible Management Availability Virtualization Platform Servers Storage Networking 4
6 Expert Integrated Systems - die nächste Generation IT- Infrastruktur IT-Systeme für das nächste Jahrzehnt entwickelt Integration von Computing, Network und Storage Multi-Hypervisor-Support (VMware, KVM, HyperV und PowerVM) Anbindung von 3rd Party Speicherlösungen (Virtualisierung SVC Code) Standard Baustein für virtuelle Workloads Integrierte Management-Software mit neuen Funktionen: Aufwärtskompatibilität in vorhandene Systems Management Lösungen (z.b. Tivoli, CA, BMC, HP) Workload-Optimierung auf Basis von benutzerdefinierten Richtlinien Durchgängiges, einheitliches Systemsmanagement Reduzierung der Admin- und Managementkosten bei gleichzeitiger Steigerung der Anpassungsfähigkeit schafft Freiräume für Innovation. 5
7 Was ist ein Software Application Pattern? Ein Software Application Pattern (Ausführungsmodell) ist : Ein Modell für eine Multi-Server Umgebung beschrieben und dargestellt in einer Datei interpretierbar und ausführbar in dem Deployment Tool zum Austausch zwischen Entwicklern und Anwendern / Teams Software Application Patterns werden über den IWD für das PureApplication System definiert werden exportiert und importiert zum Austausch zwischen Teams und anderen Systemen sind in zwei Varianten verfügbar : Virtual Applications und Virtual Systems können in mehreren Systemen verwendet werden : PureAS, IWD and SCE 6
8 -Virtual Applications und Virtual Systems -Client View -Logical View -Physical View - VMs -IPAS Client IWD and/or Image -Create Virtual Application and deploy -Image Builder -Create Virtual System -and deploy -Create Virtual System -with Custom image and deploy ConstructionTool Build (ICON) Custom Image or extend/capture & add to Catalog Custom Image Virtual Application Builder UI Virtual System Pattern UI Virtual System Pattern UI -Add Custom image to Image Catalog Cloud Group A Web Server WAS OD Router DMgr DB2 LDAP -Cloud Group B WAS WAS DB2 DB2 -Cloud Group C WAS Custom Image WAS DMgr DB2 WAS LDAP -Mgmt DB2 WAS DB2 OD Router WAS Custom Image WebServer 7-42-U -41-U -40-U -39-U -38-U -37-U -36-U -35-U -34-U -33-U -32-U -31-U -30-U -29-U -28-U -27-U -26-U -25-U -24-U -23-U -22-U -21-U -20-U -19-U -18-U -17-U -16-U -15-U -14-U -13-U -12-U -11-U -10-U -9-U -8-U -7-U -6-U -5-U -4-U -3-U -2-U -1-U
9 IBM hat die Unterstützung eines breiten Ökosystems 125 optimierte Lösungen von führenden IBM Partnern und ISVs sind bereits heute weltweit für das IBM PureApplication System zertifiziert und verfügbar Das PureSystem Center bietet: Zugang zu einem umfassenden Ökosystem von IBM und IBM zertifizierten Experten einen optimierten Download, leicht einsetzbare Anwendungsmodelle von mehr als 100 führenden ISVs eine Suchefunktion für Anwendungen auf Basis von Branchen und Systemen 8
10 9
11 Introducing the IBM PureSystems family Flex System (The elements of PureFlex and PureApplication) Management Compute Networking Storage Infrastructure System: Expert at sensing and Anticipating resource needs to optimize your infrastructure Platform System: Expert at optimally deploying and running applications for rapid time-tovalue Platform System: A data platform system optimized exclusively for delivering data services Flexible Choice Built-in expertise Integration by design Simplified Experience 10
12 IBM PureFlex - System-Konfigurationen Express - Chassis - Management Node (Standard sw) - 10Gb Network Switch - 8Gb FC Sw. - V7000 Storage w/2 ssd + 8 hdd (Power) - 2 PS 4 fans - Rack w/ Blue door - SCE (default off) Standard - Chassis - Management Node (Advanced sw) - 10Gb Network Switch - 2 x 8 Gb FC Sw. - V7000 Storage w/2 ssd + 16 hdd (Power), + 4 hdd (x, sce only) - 4 PS 6 fans - Rack w/ Blue door - SCE (default on) Enterprise - Chassis - Management Node (Advanced sw) - 2 x 10Gb Network Switch - 2 x 8 Gb FC Sw - TOR = 2 Eth, 2 FC - V7000 Storage w/ 4 ssd + 16 hdd (Power), + 4 hdd (x, sce only) - 6 PS 8 fans - Rack w/ Blue door - Chassis - SCE (default on) Selectable ITE P, x or IPL Compute Node + Operating System + Virtualization Selectable ITE P, x or IPL Compute Node + Operating System + Virtualization Selectable ITE 2P,2x or 2IPL Compute Node + Operating System + Virtualization 11
13 Die Editionen des IBM PureFlex Systems Express Standard Enterprise Infrastruktur für kleine und mittelgroße Unternehmen. Infrastruktur für Anwendungen mit einer hohen Anforderung an Integration von Servern, Storage und Netzwerk *Smart Cloud Entry Infrastruktur für skalierbare Cloud- Umgebungen mit Redundanzen für einen unbrechungsfreien Betrieb. *Smart Cloud Entry Wartung und Dienstleistungen 36 Monate Gewährleistung 5x9 36 Monate Mircocode Support Durchführung 1 x pro Jahr Lab Services (3 Tage) 36 Monate Gewährleistung 5x9 36 Monate Wartungserweiterung 7x24 36 Monate Microcode Support Durchführung 1 x pro Jahr 36 Monate Account Advocate 5x9 Lab Services (5 Tage) 36 Monate Gewährleistung 36 Monate Wartungserweiterung 7x24 36 Monate Microcode Support Durchführung 2 x pro Jahr 36 Monate Account Advocate 7x24 Lab Services (7 Tage) 12
14 13
15 14
16 15
17 16
18 17
19 18
20 19
21 Foundation Services Solutions -20 An integrated set of private cloud enablement technologies An infrastructure and platform as a service designed for enterprise-class service delivery New business and industry software as a service solutions 20
22 -Foundation -Platform as a Service Technologies -Application -Application -Application -Application -Integration Lifecycle Resources Environments Management -Infrastructure as a Service Technologies -Infrastructure -Management -Availability and -Security and -Usage and -Platform and Administration Performance Compliance Accounting Virtualized Standardized Automated -An integrated set of technologies for enabling private/hybrid clouds and the virtualization, automation and management of service delivery
23 -Foundation -SmartCloud Orchestrator -SmartCloud Provisioning -SmartCloud Entry Virtualized Standardized Automated 22
24 What s in IBM s Cloud Management Offerings? SmartCloud Entry SmartCloud Provisioning SmartCloud Orchestrator Self Service Portal for VM Provisioning Cloud Administration Multi-tenancy, Isolation Basic Single Image Composition, Manipulation Approvals / Rejection (Full workflow) Quota, Capacity Reporting and Expiration Optimized IBM Hardware, runs on all Rapid, Scalable Provisioning Automatic Fault Tolerant HW/SW Workload Mobility (composite VMs as group) Image Library (Search / Compare, Versioning, and SW Stacks) Virtual System Patterns Optimized Virtual Application Patterns Runbook Automation Solution Extensibility and Integration Hybrid cloud support Service Usage and Accounting Built in Cloud Monitoring Capacity Planning Analytics 23
25 Der Mehrwert eines IBM PureSystems Integration Einfache Beschaffung, alle Komponenten ab Werk integriert Pay as you grow Management Durchgängiges Systems-Management Für alle Infrastrukturkomponenten Inklusive der Virtualisierungsschicht Aufwärts kompatibel Automatisierung Automatisiertes Deployment von Applikationen Updates und dynamische Skalierung von Workloads Bessere Ausnutzung vorhandener Ressourcen Firmware Updates ohne Unterbrechung Support EIN zentraler Ansprechpartner für alle Servicefälle 24
26 Das Integrated Technology Element (ITE) Portfolio Systems Management Appliance Pure Systems Chassis Storage Node with Controller 2S EP & EN Intel Nodes IBM Fiber and Ethernet Switches 2S Power7 Node 2S Node with Storage Exp. 2S Node with Exp. Unit 4S EN Intel Node 4S Power7 Node 25
27 Die Chassis Details: Front - und Rückansicht 10 U (440) 14 Node Bays (7 Full Wide) Front Internal Storage Node Half Width Node bays 26
28 schematischer Aufbau des Chassis Shuttle Chassis Node Bay Shelf - Remove for Full Wide node - Remove Two Shelves for Full Wide, Double High Node 27
29 -Midplane -Passive Midplane No Active Components -Single Power Plane Supports N+N and N+1 Power Passive Midplane No Active Components (connectors only) Single Power Plane Supports N+N and N+1 Power Supports balanced three phase power Enables large node pitch (node height) required to support future technologies -Front -Management, 3 Pair x 6 Column Molex Impact -Power Supply Molex Ten60 14p30s (8p used) -Switch Power, 3 Pair Molex Impact -Rear -Switch, 4 Pair x 6 Column Molex Impact -CME (management), 2 Pair x 84 Column Molex Impact -(shown with protective covers installed) -Mezzanine, 3 Pair x 8 Column Molex Impact -Power, 60 Amp, 12VDC -Tyco MBXLe -Fan Power and Signal, Tyco MBXLe 2p24s2p -Personality Card Connector (PCIe) 28
30 -Rear -Personality Caraka VPD Card -Front -Front -Lightpipes mounted in shuttle -VPD Card -Front Panel Card 29
31 Flex Chassis Cooling Flex Chassis has four cooling zones Two primary cooling zones within the chassis for nodes Cooling adjust to the needs of the components in a cooling zone No one size fits all cooling Noise Attenuation modes (important for loudness into datacenter) 5 modes + off 5 least amount of attenuation 1 most amount of attenuation Off no attenuation NGP temperature range 5 to 40 C (41 to 104 F) < 3000ft Designed to meet ASHRAE ClassA3 See page 8 of the following
32 Cooling Paths Zoned Cooling Between Subsystems Node Cooling Zone 1+2 Power Supply Cooling Zone 3 Zoned Cooling: Nodes Left / Right Subsystems Node, Switch, and PSU Modules Industry leading fan efficiency - ~45% Switch Cooling Zone 4 31
33 Flex Chassis Power Overview Efficient use of 3-phase, 32A VAC (International) Chassis contains up to six 2500W power supplies - Supports both N+N and N+1 power redundancy - Efficient balancing of N+N power across all 3 phases - Power supply unit (PSU) is sized to efficiently use PDU power Power supplies plug to single power plane - Highly reliable midplane - no active components - PS designed to provide fault isolation High Efficiency - PSU certified to 80+ Platinum - Low power loss mid-plane and connectors 32 32
34 Data Center and Rack Power - Optimized For 3 Phase, 32 A, 230 VAC Power Building Power 230VAC, 32Amp, 3 Phase 24 A / Phase 24 A / Phase 24 A / Phase Single Phase Output VAC 12 Amps Attributes Two Chassis Fully Utilize PDU Power 12 Amps Six Power Supplies Balance 3 Phase Power Single Chassis Power Plane for Power Sharing Two to Three PS Failures Before System Failure N+N Power for Data Center Power Redundant N+1 Power by Default 72 Amps Supplied Maximum 72Amps Consumed 33
35 2500W Power Supply Output 12 VDC -Dual Sourced: Emerson and Delta -Fans - 2, 40 mm counter rotating -Input Power Connector -C19, 200 to 208 VAC; 220 to 240 VAC 34
36 Europa Power Supplys. 35
37 36
38 Das Integrated Technology Element Portfolio Systems Management Appliance Next Generation Platform Chassis Storage Node with Controller 2S EP & EN Intel Nodes IBM Fiber and Ethernet Switches 2S Power7 Node 2S Node with Exp. Unit 4S Power7 Node 37
39 System infrastructure Integration without compromise, designed for the next decade V7000 Technology Storage IBM Integrated Storage Node Faster deployment and increased administrative efficiency Up to 80% storage utilization No compromise. Get performance and cost benefits through Easy Tier Minimizes downtime for backup, restore and replication Double high / double wide Node High Performance Shared Block Storage Advanced management capabilities with Thin Provisioning, Flash Copy, Performance Management and Optimization Metro / Global Mirroring and External Virtualization options Dual hot swappable controllers for high availability Highly available shared storage, Dual controller, up to 240 SFF (HDD and SSD) Performance and features to support single to multiple chassis Next Generation Platform Node form factor and JBOD expansion module FC, iscsi, & FCoE host protocol options Integrated Storage Management Storage Virtualization of external Storage SSD Tiering (Easy Tier) 38
40 Domino DB2 Exchange ADR SVC Node vdisk ADR Management Code A hot spot is formed when an application makes frequent use of the same area of a vdisk. Here, those extents are stored on magnetic disk IO Monitor generates usage statistics and sends them to the Data Placement Advisor IOM DPA DMP DM Data Placement Advisor identifies hot spots, and outputs potential data migrations to the Data Migration Planner Data Migration Planner decides which migrations to do based on the available storage and its characteristics Data Migrator uses SVC data migration capabilities to seamlessly migrate the data to higher performing storage without any application interruption Magnetic Disk SSD 39
41 Standard Rack Enclosure Flex System Chassis Flex System Chassis Integrated scalable storage Scalable to 240 drives; clustered systems support up to 960 drives Integrated into the chassis Scalable to external rack expansion Scalable within Flex System chassis Storage node 40
42 Flex System Konfigurationen im Bereich Server und Storage Separate Server & Storage Racks Integrated Rack (w/ Internal and External Storage) External Storage Internal Chassis Storage 41
43 SAS Network Cabling 42 42
44 Das Integrated Technology Element (ITE) Portfolio Systems Management Appliance Pure Systems Chassis Storage Node with Controller 2S EP & EN Intel Nodes IBM Fiber and Ethernet Switches 2S Power7 Node 2S Node with Storage Exp. 2S Node with Exp. Unit 4S EN Intel Node 4S Power7 Node 43
45 2S Intel-EP ITE IBM Flex System x240 Standard ITE Form Factor 2-Socket Sandy Bridge-EP (Xeon E Series Processor) 135W, 130W, 115W, 95W, 80W, 70W, 60W (4 8 core) 24 LP DDR3 DIMMs / Up to 1600MHz 3 DIMMs per channel Support LRDIMMs, RDIMMs, or UDIMMs at either 1.35V or Memory with 1R/2R RDIMMs Memory Mirroring, Memory Sparing Chipkill x4 Independent Mode (4 channels) No support for Lockstep (i.e. no x8 chipkill) Up to 768GB Memory capacity with 32GB LR-DIMMs Up to 384GB Memory capacity with 16GB RDIMMs 2x2.5 Hotswap SAS/SATA/HDD/SSD LSI 2004 SAS Controller / RAID 0, 1 / 6Gbs + Optional RAID Flash-cache LOM (LAN on Motherboard) - ServerEngines / Emulex BE3 10Gb LOM supports iscsi and FCoE with FoD Models with LOM and LOM-less Up to 2 Fabric Mezzanine Cards (PCIe Gen3) Each Mezz connector: 1x16 PCIe port and 1x8 PCIe port Installing Mezz 1 card requires removal of LOM Periscope connector Embedded Hypervisor ESXi on Flash key option (2 USB Keys for redundant boot option supported on unique DIMM air baffle) Front panel one USB connector and one dongle Dongle includes two USB, video, and one serial port Management imm V2 Management Controller 44 44
46 2x IO Mezzanine Cards IBM Flex System x240 - Interior view Power Connector 2x Intel E Processors 24x LP DIMMs Power Button Keyboard, Video, Mouse Dongle Connector Front Release CAM handle 2x Hot Swap, Small Form Factor HDDs 45 45
47 Front IBM Flex System x240 - Layout Storage Backplane for 2x Hot Swap, Small Form Factor HDD/SSDs 24x LP DIMMs LOM Periscope Conn Mezz 1 SAS 10Gb LOM CPU1 CPU0 H8 immv2 Mezz 2 FPGA Power SSB 2x Intel E Processors Mezz 0 IO Expansion ITE I/F 2x IO Mezzanine Fabric Card I/Fs Management 46 46
48 System infrastructure 2S Intel-EN ITE IBM Flex System x220 Compute Standard Width compute node 2-socket Sandy Bridge-EN 12 LP DDR3 DIMMs / 1333MHz / 1600MHz 1G base with FoD to 10Gb 2 hot swap 2.5 SAS/SATA SSDs or HDDs 47
49 System infrastructure 4S Intel-EP ITE Compute Full Width compute node 4-socket Sandy Bridge-EP 48 LP DDR3 DIMMs / 1333MHz / 1600MHz 10Gb LOM 2 hot swap 2.5 SAS/SATA SSDs or HDDs 48
50 IBM Flex System x240 with the PME attached 2S x86 Node with the PME attached PME Cable 2 Extra Mezz slots PCIe Bridge Chip PCIe Full Width, Full Height Slots (x2) PCIe Low Profile Slots (x2) Compute Node PME Node Attached to Compute Node PCIe Adapters load from front 49
51 IBM Flex System Storage ITE 50
52 System infrastructure IBM Flex System x240 with 8 x SSD Storage IBM ex Flash for high IOPS storage expansion SAS Mezz Cards Supports SSDs 4 drives over DIMMs and 4 in the drive bays 1.6 TB TB Capacity Support for 200 GB drives 2 SSDs 4 SSDs (not hot-swap) 2 SSDs (These are mutually exclusive with the 2 USB Memory Keys) 51
53 System infrastructure IBM Flex System x240 with the Dual Hypervisor Compute Dual Enabled Hypervisor ESXi on Flash Key Option Available with 2s EP and EN & 4S EP x86 Compute nodes 2 Hypervisor Keys 2 Hypervisor Keys 52
54 Lightpath, LED locations, lightbox Remove ITE from chassis Push power button to activate Approx. 25 sec life 53
55 Power7 2S ITE IBM Flex System p260 54
56 IBM Flex System p260 - Layout POWER7 3.22/3.55GHz POWER7 3.22/3.55GHz DIMMs DIMMs DIMMs DIMMs DIMMs DIMMs DIMMs DIMMs Mezz 1 IO Hub IO Hub Mezz 2 SAS Controller ETE FSP Cores: 3.30 / or 3.55 GHz Max Memory: 256 GB HDDs: 300 / 600 / 900GB SSDs: 177GB IO interface cards 8Gb Fiber Channel 10Gb Ethernet HDD or SSD Mounted on cover Located over memory and connected with a ribbon cable 55
57 IBM Flex System p260 - Hard Drive Mounting 56
58 57
59 Linux Node p24l 58
60 Power7 4S ITE IBM Flex System p460 59
61 IBM Flex System p460 - Layout POWER7 3.22/3.55GHz POWER7 3.22/3.55GHz DIMMs DIMMs DIMMs DIMMs DIMMs DIMMs DIMMs DIMMs DIMMs IO Hub Mezz 2 Mezz 1 Mezz 3 Mezzanine Adapter Cores: 16 / 32 Cores Max Memory: 512 GB HDDs: 300 / 600 / 900GB SSDs: 177GB IO interface cards 8Gb Fiber Channel 10Gb Ethernet POWER7 3.22/3.55GHz DIMMs DIMMs DIMMs DIMMs DIMMs IO Hub IO Hub Mezz 4 FSP HDD or SSD Mounted on cover Located over memory POWER7 3.22/3.55GHz DIMMs DIMMs SAS Controller -Supports Dual VIOs 60
62 Processor Designs POWER5 POWER5+ POWER6 POWER7 Technology 130 nm 90 nm 65 nm 45 nm Size 389 mm mm mm mm 2 Transistors 276 M 276 M 790 M 1.2 B Cores / 6 / 8 Frequencies 1.65 GHz 1.9 GHz 3-5 GHz 3-4+ GHz L2 Cache 1.9 MB Shared 1.9 MB Shared 4 MB / Core 256 KB / Core L3 Cache 36 MB 36 MB 32 MB 4 MB / Core Memory Cntrl / 1 2 / 1 LPAR 10 / Core 10 / Core 10 / Core 10 / Core
63 IBM VIO Workload management and provisioning AIX 5L V5.3 partitions AIX 5L V5.2 Linux partitions i5/os ** Virtual I/O Server Unassigned on demand Hardware Management Console* (HMC) Hypervisor AIX 5L kernels Linux kernels Virtual Processors SLIC Virtual Networks VEnet VSCSI IVM* Virtual Storage resources Processors Service processor Memory Expansion slots Local devices and storage Networks and network storage 62
64 AIX 5L V5.3 Linux Linux AIX 5L V5.3 AIX 5L V5.3 AIX 5L V5.3 AIX 5L V 5.3 Power Prozessor 1 CPU Virtual I/O server partition -IVM -Storage sharing -Ethernet -sharing 2 CPUs -Linux Dynamically resizable CPU -i5/os -AIX 5L -V5R3**-V5.2 Virtual I/O paths Hypervisor CPUs CPUs -AIX 5L -V5.3 6 CPUs Micro-Partitioning - Virtual I/O Server Shared Ethernet Shared SCSI and Fibre Channel-attached disk subsystems Supports AIX 5L V5.3 and Linux* partitions - Micro-Partitioning Share processors across multiple partitions Minimum partition 1/10 th processor AIX 5L V5.3, Linux*, or i5/os** - Partition Load Manager**** Balances processor and memory request - Managed via HMC or IVM*** 63
65 64
66 AIX Basic s NIM mksysb smitty NMON System i nur über VIO wg. Blocksize 65
67 Intel EP ITE with LOM/1 Mezz and with 2 Mezz Cards LOM Connector (or Second Mezzanine Card) Mezzanine Card - NGP: IO Fabric Mezzanine Card - NGP: IO Fabric Mid-plane ITE with LOM Connector and 1 Mezzanine Card ITE ITE with 2 Mezzanine Cards Enables ITE LOM for NGP chassis Connects two ports from base ITE directly to NGP Chassis mid-plane 66 Periscope Removable to allow use of standard mezzanine cards Periscope and mezzanine cards engage the same mid-plane connector 66
68 67
69 68
70 Flexible IO: LOM + Mezz 1 card + Integrated Mgmt Management Links for ITE, ITME and ScSE Dual 1Gb Eth links for ITME Dual 1Gb Eth (IMM) to redundant chassis management elements (CMM) Periscope connector for LOM 10Gb Ethernet 10Gb Ethernet Management Module 2 Scalable Switch Modules LOM 2S ITME IMM IOM Bay1 IOM Bay3 IOM Bay2 IOM Bay4 FC or IB mgmt FC/IB Management Module 1 69
71 Flexible IO: LOM or Mezz 1 + Mezz 2 card Periscope connector for LOM 10Gb Ethernet 10Gb Ethernet Management Module 2 ITE 2 p Eth LOM imm2 IOM Bay1 IOM Bay3 IOM Bay2 IOM Bay4 IOM Bay1 IOM Bay3 IOM Bay2 IOM Bay4 FC or IB FC/IB Management Module 1 Each ITE supports LOM + two Mezz cards Mezz card 1 connects to ScSE 1 and 2 Mezz card 2 connects to ScSE 3 and 4. 70
72 Flexible IO Scale for Bandwidth or Redundancy or both Mezz Card 1 with 4 Eth ports Mezz Card 2 with 2 FC/IB ports Periscope connector removed for Mezz card 1 Management Module 2 10Gb Ethernet 10Gb Ethernet Scalable Switch Modules 2S ITE 4 p LOM Eth imm2 10Gb Ethernet 10Gb Ethernet IOM Bay1 IOM Bay3 IOM Bay2 IOM Bay4 FC or IB FC/IB Management Module 1 71
73 Das Integrated Technology Element (ITE) Portfolio Systems Management Appliance Pure Systems Chassis Storage Node with Controller 2S EP & EN Intel Nodes IBM Fiber and Ethernet Switches 2S Power7 Node 2S Node with Storage Exp. 2S Node with Exp. Unit 4S EN Intel Node 4S Power7 Node 72
74 73
75 Adapter Switch IO Roadmap Ethernet & FCoE Fibre Channel InfiniBand 52 port 1Gb Switch Base: 14/10 (internal/external) 64 port 10Gb Ethernet Switch Base: 14/10 1/10Gb Pass Thru 20 port 8Gb (Qlogic) 20 port 8Gb Pass Thru (Qlogic) 48 port 16Gb (Brocade) QDR Switch Mellanox upgrade: FDR 4 port 1Gb - Broadcom 4 port 10Gb - Emulex 2 port 10Gb - Mellanox 2 port 8Gb Qlogic 2 port 8Gb Emulex 2 port 8Gb -- Brocade QDR & FDR Adapter - Mellanox 74 74
76 IBM 10Gb Virtual Fabric Switch Pool of uplink ports Next generation Flexibility Scale for Bandwidth or Ports or both IBM 10Gb Switch: Wired for up to three 10Gb ports per node and twenty two external ports. 14 internal ports Logical partition 1 Base Switch: Enables fourteen internal 10Gb ports (one to each server) and ten external 10Gb ports Supports the 2 port 10Gb LOM and Virtual Fabric capability First Upgrade via FoD: Enables second set of fourteen internal 10Gb ports (one to each server) and two 40Gb ports 14 internal ports Logical partition 2 Each 40Gb port can be used as four 10Gb ports Supports the 4-port Virtual Fabric adapter 14 internal ports Logical partition 3 Second Upgrade via FoD: Enables third set of fourteen internal 10Gb ports (one to each server) and four external 10Gb ports Capable of supporting a six port card in future 75
77 IBM 1Gb Scalable switch Key Features Dual Density switch 52 port Switch. 28 internal 1Gb ports and 20 external 1Gb ports & 4 external 10Gb ports Base: 14 internal 1Gb ports and 10 1Gb RJ45 ports Upgrade 1: 4 10Gb uplinks. Upgrade 2: 14 internal 1Gb ports and 10 external 1Gb RJ45 ports Upgrade 1 can be applied to base or to upgrade 2. 10Gb SFP+ ports can function at 1Gb or 10Gb L2 Ethernet functionality 10 RJ-45 1GbE uplink Ports Upgrade 10 1Gb Upgrade 4 10Gb Base 76 IBM Confidential 76
78 IBM 10Gb Scalable switch Key Features Triple Density switch 64 port Switch. 42 internal 10Gb ports and 22 external 10Gb ports Base: 14 internal 10Gb ports and 10 external SFP+ 10Gb ports Upgrade 1: Two 40Gb QSFP ports that can be used as 8 10Gb ports. Upgrade 2: 14 internal 10Gb ports and 4 external SFP+ 10Gb ports Upgrade 1 required to apply upgrade 2. 10Gb SFP+ ports can function at 1Gb or 10Gb 40Gb QSFP ports can function at 10Gb or 40Gb L2/L3 Ethernet functionality Virtual Fabric Support CEE support coming 2Q12 10 uplink Ports (SFP+) Upgrade #2 2x40G Ports QSFP (or 8x10Gb) Upgrade option #1 Base 77 77
79 IBM 10Gb Pass Thru module Key Features 14 internal 10Gb ports and 14 external 10Gb ports Auto negotiates to 1Gb Unmanaged module. No switching. Virtual Fabric Support CEE support Kein support für 4 Port Ethernet Adapter! 78 78
80 SAN Switche 79
81 Das Integrated Technology Element (ITE) Portfolio Systems Management Appliance Pure Systems Chassis Storage Node with Controller 2S EP & EN Intel Nodes IBM Fiber and Ethernet Switches 2S Power7 Node 2S Node with Storage Exp. 2S Node with Exp. Unit 4S EN Intel Node 4S Power7 Node 80
82 Flex System Management Appliance 32 GB of memory 8 Core CPU 2 Solid State Drives (200 GB) Raid 1 mirrored drives 1TB HDD drive 2, Solid State Drives Cover Over Solid State Drives Connection into Private Management Network 81
83 Next Generation Platform w/ Integrated Chassis Management Chassis Mgmt Chassis Management Module Provides BladeCenter customers straight-forward transition from familiar Chassis Level management model Provides backward compatibility w/ BladeCenter AMM Commands Flex System Management Appliance Adds easy-to-use multi-chassis management Integrated x86 & Power servers, Storage & Network management Network fabric management Virtualization Management including resource pools Workload Management and Placement Advisors Robust Security Energy Management Failover to redundant NGP Management Appliance Advanced management capabilities available thru priced add-ons NGP CMM Single Chassis Management Multiple Chassis Mgmt NGP Management Appliance Base & Extensions Platform Mgr. Chassis Mgr. Storage Mgr Active Energy Mgr Network Mgr POWER SW Multi-Chassis Management Appliance IBM Confidential 82
84 PureFlex System Manager is the accelerator for IBM s integration strategy Enable Resiliency & Simplicity Extensible Highly Available Scalable, Hierarchical Headless, embeddable Appliance ready -Integrate IBM Drive tighter integration with Tivoli, Storage, and Research groups Integrated management for Workload Optimized Systems -Lead in Virtualization Management Virtualization Lifecycle Management Capture and deploy workloads with VMControl -Platform and Virtualization Management -Integration -Manage Storage, Network & Security Storage, I/O and Network virtualization Enable compliance and cloud security offerings -Optimize Energy Usage Reduce operational costs with smarter energy monitoring & management -Expand Ecosystem and Usage Deliver REST Web services integration Extend IHV/ISV coverage OEM and branding services Manage non-ibm resources -PureFlex System Manager - the Secret Sauce for IBM PureFlex IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 83
85 Platform Management Expertise inside PureFlex System Manager Simplified management to optimize your datacenter -Servers -Network -Storage -Security -Virtualization -Mobile UI -PureFlex System Manager Comes pre-installed and pre-configured Auto-discovery and inventory of hardware Single pane of glass Fully integrated across compute, network, and storage User friendly chassis maps IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change Born virtualized so you can deploy workloads day one 84
86 Efficiency, control, and agility -Efficiency Consolidation / Virtualization -Control -Open / Dynamic -Agility Deploy / Performance Improve efficiency and utilization through integration Improve control through simplicity, automation, compliance / security Increase agility and flexibility at the enterprise level IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 85
87 Key functions: Platform management -Integrated Management via PureFlex System Manager Initial Set Up and Time to Value Lifecycle Management Discovery / Inventory Monitoring and Automation Plans Configuration Update -CMM/IMM/IOM New Look and Feel with Backward Compatibility Launch in Context Role based Security -Power Systems Management Full Configuration VIOS Manipulate Power compute nodes IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 89
88 Server Management Simplified Setup: Start, manage, learn Monitor Resources: Health Summary, Alerts, Thresholds, Updates, Service / Support Visualize / Navigate Physical and Virtual Relationships: Intuitive drilldown / Views, Topology map, finger tip trouble shooting Automate Responses: Custom actions / filters, configure, edit, relocate, automation plans Manage firmware and Software updates: Set policies to track and automate firmware and software compliance. -90 IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 90
89 Storage Management Integrated with virtual server management, allowing virtual disks to be defined and attached Dynamic storage provisioning as part of image deployment Enable policy-driven placement within storage system pools -Hypervisor -Hypervisor -Virtual I/O Stack -(intrinsic to hypervisor or external) Dynamic zoning/masking as part of virtual server relocation Integration with IBM Tivoli Storage Productivity Center (TPC) XiV -Filesystem -Storage Pools Storwize v7000 TPC SVC IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 91
90 Network management Discovery, inventory, and status monitoring of switches Graphical network topology views -VLAN 500 -VSI Type ID -VLAN 300 Support for KVM, phyp, and VMware virtual switches as well as physical switches Basic protocol and VLAN configuration of switches Integration with server management -Logical Network Profile A (VEB) -Logical Network Profile B (VEB and VEPA) -Logical Network Profile C (VEPA) -Logical Network - A -Logical Network - B -Logical Network - C Provides per-virtual machine network usage and performance statistics to VMControl -Server System -Pool -Network System Pool -Server System -Pool Logical views of servers and network devices grouped by subnet and VLAN Provides the ability to automatically provision and move VLANs for virtual machines -Server System Pool IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 92
91 Security management Secure Chassis integrating secure boot, secure protocols, user management, signed firmware and planned support for TCG Dynamic Root of Trust Measurement (DRTM). Enforce central policy for components All components running with the same security policy provided by CMM Enforced by the management controllers, secure IO Modules and DRTM Locks" settings to prevent user from inadvertently or maliciously enabling insecure protocols Ensures all IO modules running with hardened attack surface Centralized management of user accounts and authorization Ensures consistent set of users/roles/authorities Ensures no "back door" user accounts exist Vulnerability Analysis End-to-end audit logs Identification and remediation Secure boot and TCG standards (with planned DRTM compliance for ITEs) IBM leadership in adoption of new security standards Delivers secure infrastructure for multi-tenant / cloud applications Includes management controllers in trust domain Hardware SPI headers to validate firmware authenticity (detect supply-chain attacks) IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 93
92 Energy management Activated and monitoring chassis by default Monitors, Thresholds, Trending, Cost Calc, SDK, CLI, Provides energy readings for CMM Chassis and subsystems (Cooling, Power, ITE, Switch) IMM System x ITE FSP Power System ITE Provide energy input for PureFlex System Manager chassis GUI view Power Capping, Power Savings, Chassis Power Redundancy, Outlet Control, Energy Policies IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 94
93 -Mobile Management Designed optimized and simplified for mobile scenarios and handheld limitations Multi-chassis monitoring on a mobile platform Killer app - users say they d switch mobile devices to use it -Multi-chassis -Chassis -Blade IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 95
94 Key functions: Virtualization management -Virtualization Management Lifecycle Management (Create, edit, start/stop, delete VMs) for all Hypervisors Image Management (Capture, Edit, Deploy) for PowerVM and KVM Resource Pooling for Storage, Network, and Virtual Servers (PowerVM and KVM) Virtual Mobility and policy driven placement for PowerVM and KVM workloads Use existing VCenter capabilties for VMWare -Network Virtualization Discovery and Configuration of Network Elements -Storage Virtualization Discovery and Configuration of External Storage devices a la etpc Includes auto discovery of Storwize v7000 IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 96
95 Virtualization management Virtualization Management Manage Virtual Servers and Hosts HMC and Systems VS Life-cycle management Topology Maps Create empty virtual server Monitoring, automation Capture, deploy Edit virtual resources Edit Hosts Edit Virtual Servers GUI or command line Launch to Platform Manager Relocate Live relocation Plan for relocation IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 97
96 PureFlex Fabric Management Server deployment LAN and SAN administrators don t need to wait for the hardware to arrive Done ahead of time MAC and WWNs IP address assignments SAN zoning Storage LUN masking Server replacement No need to reconfigure LAN/SAN resources when a Server is replaced SAN zoning and LUN masking is unaffected Replacement Servers in the same slots retain MAC and WWN addresses Server failover Fully Automated Failover Network and storage switch independent Launched from PureFlex Management Appliance IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 98
97 Key functions: Configuration and support -Configuration Manager plug-ins outside of using CMM -Remote Presence -Service & Support Manager w/call Home Configure Chassis and Internal Switch Components Configuration of Compute Nodes Login and take over Compute node from Administrators console Mount DVD drive remotely Perform Bare Metal Install remotely Automatically detect and log HW Problems Notify IBM directly of HW Outages IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 99
98 PureFlex System Firmware and Software Compliance Manage updates from one pane of glass Automatically check for new updates Show and install updates needed by your systems Monitor system compliance Create compliance policies to automatically notify you when a system is out of date Show and resolve compliance issues to install the missing updates IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 100
99 Remote Control New Thumbnail bar best of breed Can monitor multiple sessions in one console -Watch a reboot progress in background -Flyover Details -Resizable IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change -Powerful Toolbar power on/off, mount local files, etc. 101
100 Additional PureFlex System Manager capabilities Future PureFlex System Manager Functions: Chassis Map Overlays Display Status of Chassis Components Energy Characteristics of Components LED status Display LED Status on Chassis Map Remotely activate/deactivate/flash LEDs Energy Management Energy and Environmental Status Monitoring Energy management capabilities Energy Policies for Workload Management Security PureFlex System Manager Centralized User Management Centralized Security Policy Unified Fabric Management IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 102
101 Additional Future PureFlex System Manager capabilities Internal Storage Management Internal V7000 Support FCoE and SMI-S Converged Switch Element Manager LiC Multi Chassis Mgmt Manage Multiple PureFlex System Managers from Single Control Point Increased Scalability (17 Chassis from 1 PureFlex System Manager) Fuel Gauge (Metering) for PureFlex System Manager UI Enhancements Translation to Tier 1 languages Networking Fabric Optimization Workload Optimization Osiris Virtual Switch SNEM Lite RAS Enhancements PureFlex System Manager Resiliency Ease of Use / Time to Value Systems Profiles Bare Metal Deployment Out of Band Updates Advanced Workload Management Mobile Management IBM Confidential For IBM and Business Partner Education Use Only Plans Subject to Change 103
102 NGP Management Appliance Software Stack IBM NGP Management Appliance Resource Optimization Active Energy Manager Storage Control (Embedded TPC) VM Control Network Control Resource Life Cycle Management Base and Agent Service and Support Manager NGP Platform Manager Extension Dashboard UI - Graphical Chassis Map Auto Discovery Quick Start Wizards Centralized User & Security Mgmt Open Fabric Manager Remote Console Feature on Demand Network Control Fabric Management Systems Director Management Console (SDMC) for Power ITEs 104
103 FSM Screenshot 105
104 Screenshot FSM 106
105 IBM Systems Director Editions Version 6.3 Products System x Power Systems Express Express Standard Enterprise IBM System Director 6.2 Active Energy Manager 4.3 Monitoring Management (including Max Perf Mode) VMControl 2.3 Express Standard (Express + Image Mgmt) Enterprise (Standard + System Pools) Network Control 1.2 (including ITNM Discovery) Transition Manager 6.2 for HP SIM Service and Support Manager 6..2 ITM base FP2 (TEPS, TDW, TCR) TADDM v7.2 ITM for Energy Management V6.2.1 DB2 ESE V9.7 FP1 TCR 1.3 ITM System p Agents ITM V6.2.2 Tivoli Perf Analyzer ITM V6.2.2 Tools FP2 ITM V6.2.2 UNIX/Win/Linux Agent FP2 Install Launchpad V6.2 (STG and Tivoli products) Support Worldwide SWMA SWMA SWMA SWMA 107
106 Hot Air Recirculation Detection Smarter Solutions - Chassis Management Module will monitor and compare inlet temperatures across chassis inlet and nodes 108
107 Benefit of Rack Floor Recirculation Baffle Actual client installation with real measured benefit -16 o C -23 o C -Bottom Open to Recirculation -Baffle Installed - Bottom Closed to Recirculation - Rack baffles enabled reduction in CRAC set points - Provided 19kW in Savings at Room Level! 109
108 -New Rear Door Heat Exchanger - Chiller and CDU are not part of the Flex Cooling Option - Building Water Chiller - CDU (Cooling Distribution Unit) - Rack Mount or Standalone - Water Conditioning Unit Keeps building water separate from building water 1. Maintains clean water to Rear Door 2. Maintains water temperature 3. Maintains water pressure 4. Limits spill volume during fault 110
109 Optimized for Enhanced Cooling & Cable Management FLEX SYSTEM is compatible with standard 19 racks. Railhawk offers additional features. Cable Egress Thermal Sealing Plane (front EIA flange) Key Design Features: - 42U height mm width x 1100 mm depth mm deep with rear door water cooled heat exchanger - 50 lbs/eia weight capacity - Ship-loadable via outriggers - Square EIA rail mount points - Supports 4 strip (zero U) PDUs - 3 PDU pockets per side, 6 per rack - Plentiful cable egresses - Cable trays front to back - Support Dagger RDHx Rear PDU Access 6x Cable Channels Strip PDU Support 4X Cable Tie Points Cable Egress Cable Channels Front of Rack Cable Egress Floor Baffle/Skirt Outrigger 111
110 112
111 113
112 114
113 Bladecenter Chassis 115
114 BC E Basics -Upper Midplane -Half -Upper and -lower -Processor -Blade -connectors -Lower Midplane -Half 116
115 BC H Basics 117
116 BC-H Midplane -Power Module Connectors -Blade power connector 118
117 BC H Topology 119
118 120
119 HS23 121
120 BC-H Chassis Änderungen 122
121 Neue Lüfter 123
122 124
123 IBM System x Gesamtpräsentation -Die aktuellste Version ist auf Download zu finden!
124 Ressourcen im Internet (Partnerworld und IBM BusinessPartner Guidebook (Partnerworld Login nötig zum Download) Basis Informationen für neue BP s Quick-Facts Deutsch Produkte System x Literatur Broschüren IBM System x Produktübersicht Datenblätter Deutsch Produkte System x Literatur Broschüren Datenblätter IBM System x Pricebook Excel Übersicht IBM System x Produkte mit Listpreisen Technical Delivery Assessment (TDA) [Solution Assurance] Qualitätssicherungsprozess für gelungene Projekte ServicePac Selector Tool Tool um die passenden ServicePacs zu suchen 126-1
125 IBM Presales Tools Configuration and Options Guide Welcher Adapter passt in welchen Slot xref Hardware Details Specs der Server Serve Raid Quick Reference Guide & Redbooks Fotos der Raid Adapter und was kann welcher Adapter und wo passt er rein Power Konfigurator Berechnung des Stromverbrauchs / BTU s Serverproven und SSIC Welches Betriebssystem ist auf dem Server (und Adapter) supportet Announcement Letters Ankündigungsschreiben der Server & verbindliche Garantieinformationen CRU replacement Video s Wie baue ich meinen Server zusammen IBM Systems College und System Connect expert Online Ausbildung durch IBM IBM System x Techline Support Repository Online Kompendium für IBM System x
126 IBM Presales Tools (Sonstige wichtige Informationsquellen) Sametime Gateway für IBM Businesspartner IBM Support Foren IBMquicklinks Redbooks (Newsletter anmelden) My Support notification (IBM System x) IBM Server xpert Group IBM PSC Websites 128
127 IBM Presales Tools econfig, Compete Sales Tools (CompeteCenter), Techline, Supportline, Tiger Team 129
128 Für Euch hängen wir uns voll rein! Rainer Korda Hirschbergstrasse 1 D Poing rainer@korda-it.com 130
129 Die Familie der Expert Integrated Systems client tuned systems expert integrated systems Einzel- Komponenten Flex System Build to Order: basierend auf System x, Storage, und Networking ITEs PureFlex System Express Standard (SCE) Enterprise (SCE) PureApplication System S,M, L & XL PureBusiness System Kundeneigene Konfiguration mit optimierten Komponenten Ab Werk Integrierte, aufeinander abgestimmte und optimierte Infrastruktur Ab Werk Integrierte und optimierte application platform z.b. für Datenbank oder Web Anwendungen Ab Werk integrierte application platform für hoch optimierte business applications (Z.B. ERP, DWH und Indutrielösungen) Viele verschiedene Workloads Viele verschiedene Workloads Einige pre tuned workloads Ausgewählte highly tuned workloads 131
Expert Integrated Systems. Sales Überblick. 2012 IBM Corporation
2012 Expert Integrated Systems Sales Überblick 2012 IBM Corporation Test 000-780: IBM PureFlex System Sales V1 Die Schaffung eines integrierten Systems adressiert die wachsenden IT-Herausforderungen. Networking
More informationpræsentation oktober 2011
Johnny Olesen System X presale præsentation oktober 2011 2010 IBM Corporation 2 Hvem er jeg Dagens agenda Server overview System Director 3 4 Portfolio-wide Innovation with IBM System x and BladeCenter
More informationCloud Infrastructure Management - IBM VMControl
Cloud Infrastructure Management - IBM VMControl IBM Systems Director 6.3 VMControl 2.4 Thierry Huche IBM France - Montpellier thierry.huche@fr.ibm.com 2010 IBM Corporation Topics IBM Systems Director /
More informationPrivate Cloud on Pure Systems. Smarter Computing Solutions 2012 Briefing
Private Cloud on Pure Systems Smarter Computing Solutions 2012 Briefing Overwhelming IT Complexity Drives Cost Up $217 B $247 B est. $100 B 8% 29% 63% $130 B 11% 43% 46% $175 B 16% 33% 51% 12% 22% 66%
More informationPowerVC 1.2 Q4 2013 Power Systems Virtualization Center
PowerVC 1.2 Q4 2013 Power Systems Virtualization Center At last a simple tool to spin-off Power Virtual Machines with very little effort Nigel Griffiths IBM Power Systems Corporation Advanced Technology
More informationUCS M-Series Modular Servers
UCS M-Series Modular Servers The Next Wave of UCS Innovation Marian Klas Cisco Systems June 2015 Cisco UCS - Powering Applications at Every Scale Edge-Scale Computing Cloud-Scale Computing Seamlessly Extend
More informationThe Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer
The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration
More informationCisco Unified Computing System Hardware
Cisco Unified Computing System Hardware C22 M3 C24 M3 C220 M3 C220 M4 Form Factor 1RU 2RU 1RU 1RU Number of Sockets 2 2 2 2 Intel Xeon Processor Family E5-2400 and E5-2400 v2 E5-2600 E5-2600 v3 Processor
More informationPower Redundancy. I/O Connectivity Blade Compatibility KVM Support
1.Blade server Blade Chasis Specification Blade Chassis Form Factor 6U-10U rack mountable Chasis to House at least 6 or more Blade Servers Chasis Should be configured with 6 blades Network Redundancy I/O
More informationIBM PureData System for Transactions. Technical Deep Dive. Jonathan Rossi, PureSystems Specialist rossij@us.ibm.com
IBM expert integrated system Technical Deep Dive Maria N. Schwenger, PureSystems Specialist schwenge@us.ibm.com Jonathan Rossi, PureSystems Specialist rossij@us.ibm.com IBM PureData System for Transactions
More informationHow To Build A Cisco Ukcsob420 M3 Blade Server
Data Sheet Cisco UCS B420 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C-Series Rack Servers with networking and storage
More informationShifting Gears: VMControl to PowerVC
ATS Experts Exchange November 2013 Shifting Gears: VMControl to PowerVC Glen Corneau, Agenda A review of VMControl Express, Standard and Enterprise Editions Image repositories System Pools PowerVC Based
More informationPrivate cloud computing advances
Building robust private cloud services infrastructures By Brian Gautreau and Gong Wang Private clouds optimize utilization and management of IT resources to heighten availability. Microsoft Private Cloud
More informationMicrosoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products. IBM Systems and Technology Group ISV Enablement January 2014
Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products IBM Systems and Technology Group ISV Enablement January 2014 Copyright IBM Corporation, 2014 Table of contents Abstract...
More informationPCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation
PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies
More informationSUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater
More informationHUAWEI Tecal E6000 Blade Server
HUAWEI Tecal E6000 Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The HUAWEI Tecal E6000 is a new-generation server platform that guarantees comprehensive and powerful
More informationIBM BladeCenter H with Cisco VFrame Software A Comparison with HP Virtual Connect
IBM BladeCenter H with Cisco VFrame Software A Comparison with HP Connect Executive Overview This white paper describes how Cisco VFrame Server Fabric ization Software works with IBM BladeCenter H to provide
More informationMicrosoft Hybrid Cloud IaaS Platforms
IronPOD 400 Converged Systems Series Microsoft Hybrid Cloud IaaS Platforms IronPOD System 400 Series System Overview IRON Networks converged system products simplify Microsoft infrastructure deployments
More informationMaxDeploy Ready. Hyper- Converged Virtualization Solution. With SanDisk Fusion iomemory products
MaxDeploy Ready Hyper- Converged Virtualization Solution With SanDisk Fusion iomemory products MaxDeploy Ready products are configured and tested for support with Maxta software- defined storage and with
More informationUNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment
DATASHEET TM NST6000 UNIFIED HYBRID STORAGE Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment UNIFIED The Nexsan NST6000 unified hybrid storage appliance is ideal for
More informationMESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220
MESOS CB220 Cluster-in-a-Box Network Storage Appliance A Simple and Smart Way to Converged Storage with QCT MESOS CB220 MESOS CB220 A Simple and Smart Way to Converged Storage Tailored for SMB storage
More informationData Sheet Fujitsu PRIMERGY BX400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server Blade Made Easy Fujitsu PRIMERGY BX Blade Servers provide a faster, simpler and lower-cost way to build and run an IT infrastructure in your midsize organization,
More informationGrid on Blades. Basil Smith 7/2/2005. 2003 IBM Corporation
Grid on Blades Basil Smith 7/2/2005 2003 IBM Corporation What is the problem? Inefficient utilization of resources (MIPS, Memory, Storage, Bandwidth) Fundamentally resources are being wasted due to wide
More informationMit Soft- & Hardware zum Erfolg. Giuseppe Paletta
Mit Soft- & Hardware zum Erfolg IT-Transformation VCE Converged and Hyperconverged Infrastructure VCE VxRack EMC VSPEX Blue IT-Transformation IT has changed dramatically in last past years The requirements
More informationFujitsu PRIMERGY Servers Portfolio
Fujitsu Servers Portfolio Complete server solutions that drive your success shaping tomorrow with you Higher IT efficiency and reduced total cost of ownership Fujitsu Micro and Tower Servers MX130 S2 TX100
More informationRemote/Branch Office IT Consolidation with Lenovo S2200 SAN and Microsoft Hyper-V
Remote/Branch Office IT Consolidation with Lenovo S2200 SAN and Microsoft Hyper-V Most data centers routinely utilize virtualization and cloud technology to benefit from the massive cost savings and resource
More informationVTrak 15200 SATA RAID Storage System
Page 1 15-Drive Supports over 5 TB of reliable, low-cost, high performance storage 15200 Product Highlights First to deliver a full HW iscsi solution with SATA drives - Lower CPU utilization - Higher data
More informationIBM PureSystem: evoluzione ed integrazione dei sistemi per la semplificazione dell IT
Patrizia Guaitani PureSystems Technical Leader, Senior Infrastructure Architect 25 settembre 2013 IBM PureSystem: evoluzione ed integrazione dei sistemi per la semplificazione dell IT Document number Market
More informationConfiguration Maximums
Topic Configuration s VMware vsphere 5.1 When you select and configure your virtual and physical equipment, you must stay at or below the maximums supported by vsphere 5.1. The limits presented in the
More informationSAN TECHNICAL - DETAILS/ SPECIFICATIONS
SAN TECHNICAL - DETAILS/ SPECIFICATIONS Technical Details / Specifications for 25 -TB Usable capacity SAN Solution Item 1) SAN STORAGE HARDWARE : One No. S.N. Features Description Technical Compliance
More informationImproving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200
Improving IT Operational Efficiency with a VMware vsphere Private Cloud on Lenovo Servers and Lenovo Storage SAN S3200 Most organizations routinely utilize a server virtualization infrastructure to benefit
More informationAccelerate private cloud with Data#3 and IBM
Accelerate private cloud with Data#3 and IBM Integrated, cloud accelerated solutions Nick Day, IBM: Chris Farrow, Data#3: sbcday@au1.ibm.com chris_farrow@data3.com.au Agenda Why are Australian organisations
More informationUnified Computing System When Delivering IT as a Service. Tomi Jalonen DC CSE 2015
Unified Computing System When Delivering IT as a Service Tomi Jalonen DC CSE 2015 Key Concepts 2 Unified Computing Product Innovation Manager Comprehensive Role-Based Management and Automation for Ease
More informationCopyright 2013, Oracle and/or its affiliates. All rights reserved.
1 Oracle SPARC Server for Enterprise Computing Dr. Heiner Bauch Senior Account Architect 19. April 2013 2 The following is intended to outline our general product direction. It is intended for information
More informationDD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
More informationIBM PureFlex System. The infrastructure system with integrated expertise
IBM PureFlex System The infrastructure system with integrated expertise 2 IBM PureFlex System IT is moving to the strategic center of business Over the last 100 years information technology has moved from
More informationDeploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform
1 Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform Implementation Guide By Sean Siegmund June 2011 Feedback Hitachi Data Systems welcomes your feedback.
More informationFujitsu PRIMERGY BX Blade Server
Fujitsu PRIMERGY BX Blade Server Driving your success with unbeatable performance and efficiency Highlights Inhalt Highlights 2 IT requirements and challenges 3 Fujitsu PRIMERGY Blade Server Server consolidation
More informationSMB Direct for SQL Server and Private Cloud
SMB Direct for SQL Server and Private Cloud Increased Performance, Higher Scalability and Extreme Resiliency June, 2014 Mellanox Overview Ticker: MLNX Leading provider of high-throughput, low-latency server
More informationTipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2
Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,
More informationHP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN
HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN Table of contents Executive summary... 2 Introduction... 2 Solution criteria... 3 Hyper-V guest machine configurations...
More informationManagement of VMware ESXi. on HP ProLiant Servers
Management of VMware ESXi on W H I T E P A P E R Table of Contents Introduction................................................................ 3 HP Systems Insight Manager.................................................
More informationHitachi Unified Compute Platform (UCP) Pro for VMware vsphere
Test Validation Hitachi Unified Compute Platform (UCP) Pro for VMware vsphere Author:, Sr. Partner, Evaluator Group April 2013 Enabling you to make the best technology decisions 2013 Evaluator Group, Inc.
More informationDeploying Microsoft Exchange Server 2010 on the Hitachi Virtual Storage Platform with Hitachi Dynamic Tiering
1 Deploying Microsoft Exchange Server 2010 on the Hitachi Virtual Storage Platform with Hitachi Dynamic Tiering Reference Architecture Guide By Jeff Chen May 2011 Month Year Feedback Hitachi Data Systems
More informationIBM i on a POWER blade (read-me first)
IBM i on a POWER blade (read-me first) Installation and Configuration Guide Mike Schambureck and Keith Zblewski (schambur@us.ibm.com and zblewski@us.ibm.com) IBM i Lab Services,Rochester, MN April 2013
More informationA Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.
Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density
More informationHow To Write An Article On An Hp Appsystem For Spera Hana
Technical white paper HP AppSystem for SAP HANA Distributed architecture with 3PAR StoreServ 7400 storage Table of contents Executive summary... 2 Introduction... 2 Appliance components... 3 3PAR StoreServ
More informationUN 4013 V - Virtual Tape Libraries solutions update...
UN 4013 V - Virtual Tape Libraries solutions update... - a Unisys storage partner Key issues when considering virtual tape Connectivity is my platform supported by whom? (for Unisys environments, MCP,
More informationIBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack, BladeCenter and tower servers 2 IBM System x family brochure Highlights IBM System x and BladeCenter servers help deliver
More informationGetting started with IBM i on an IBM Flex System compute node.
F Getting started with IBM i on an IBM Flex System compute node. Mike Schambureck (schambur@us.ibm.com) IBM i Lab Services,Rochester, MN Jan 2013 Getting Started with IBM i on an IBM PureFlex System Compute
More informationCisco UCS B200 M3 Blade Server
Data Sheet Cisco UCS B200 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C-Series Rack Servers with networking and storage
More informationIBM Upward Integration Module (UIM) Advanced Technical Sales Wayne Wigley
IBM Upward Integration Module (UIM) Advanced Technical Sales Wayne Wigley 1 Agenda vsphere Architecture with Required IBM Components for UIM ESXi Images IBM Customized Image IBM Upward Integration for
More informationTechnical Brief: Egenera Taps Brocade and Fujitsu to Help Build an Enterprise Class Platform to Host Xterity Wholesale Cloud Service
Technical Brief: Egenera Taps Brocade and Fujitsu to Help Build an Enterprise Class Platform to Host Xterity Wholesale Cloud Service ... Egenera needed an enterprise class platform to host their wholesale
More informationCisco UCS C24 M3 Server
Data Sheet Cisco UCS C24 M3 Rack Server Product Overview The form-factor-agnostic Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking
More informationFujitsu PRIMERGY Servers Portfolio
Fujitsu Servers Portfolio Dynamic Infrastructures for workgroup, datacenter and cloud computing shaping tomorrow with you Higher IT efficiency and reduced total cost of ownership Fujitsu Micro and Tower
More informationConfiguration Maximums
Configuration s vsphere 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions
More information1. Specifiers may alternately wish to include this specification in the following sections:
GUIDE SPECIFICATION Seneca is a leading US designer and manufacturer of xvault security and surveillance solutions. The xvault product line combines our IP expertise and solution partnerships with certified
More informationORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK
ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK KEY FEATURES PROVISION FROM BARE- METAL TO PRODUCTION QUICKLY AND EFFICIENTLY Controlled discovery with active control of your hardware Automatically
More informationCapacity planning for IBM Power Systems using LPAR2RRD. www.lpar2rrd.com www.stor2rrd.com
Capacity planning for IBM Power Systems using LPAR2RRD Agenda LPAR2RRD and STOR2RRD basic introduction Capacity Planning practical view CPU Capacity Planning LPAR2RRD Premium features Future STOR2RRD quick
More informationCUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers
CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW Dell PowerEdge M-Series Blade Servers Simplifying IT The Dell PowerEdge M-Series blade servers address the challenges of an evolving IT environment by delivering
More informationTerms of Reference Microsoft Exchange and Domain Controller/ AD implementation
Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation Overview Maldivian Red Crescent will implement it s first Microsoft Exchange server and replace it s current Domain Controller
More informationAchieve Automated, End-to-End Firmware Management with Cisco UCS Manager
Achieve Automated, End-to-End Firmware Management with Cisco UCS Manager What You Will Learn This document describes the operational benefits and advantages of firmware provisioning with Cisco UCS Manager
More informationUnified Computing Systems
Unified Computing Systems Cisco Unified Computing Systems simplify your data center architecture; reduce the number of devices to purchase, deploy, and maintain; and improve speed and agility. Cisco Unified
More informationHow To Run A Power5 On A Powerbook On A Mini Computer (Power5) On A Microsoft Powerbook (Power4) On An Ipa (Power3) On Your Computer Or Ipa On A Minium (Power2
Planning for Virtualization Jaqui Lynch Userblue Jaqui.lynch@mainline.com http://www.circle4.com/papers/ubvirtual.pdf Agenda Partitioning Concepts Virtualization Planning Hints and Tips References 1 Partitioning
More informationCisco UCS B440 M2 High-Performance Blade Server
Data Sheet Cisco UCS B440 M2 High-Performance Blade Server Product Overview The Cisco UCS B440 M2 High-Performance Blade Server delivers the performance, scalability and reliability to power computation-intensive,
More informationHow To Buy An Fujitsu Primergy Bx400 S1 Blade Server
Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server BLADE MADE EASY - tailor-made for medium-sized companies Fujitsu PRIMERGY BX Blade Servers meet all the requirements of medium-sized companies as well
More informationPioneer DreamMicro. Blade Server S75 Series
Pioneer DreamMicro Blade Server S75 Series Advantage of Blade Server? Easy Maintenance Hot Swappable High Availability Redundant Architecture Space Saving Cableless Rack Mount Server Blade Server Pioneer
More informationAnnex 1: Hardware and Software Details
Annex : Hardware and Software Details Hardware Equipment: The figure below highlights in more details the relation and connectivity between the Portal different environments. The number adjacent to each
More informationHP Cloudline Overview
HP Cloudline Overview Infrastructure for Cloud Service Providers Dave Peterson Hewlett-Packard Company Copyright 2015 2012 Hewlett-Packard Development Company, L.P. The information contained herein is
More informationIBM PureSystems: Familia de Sistemas Expertos Integrados
IBM PureSystems: Familia de Sistemas Expertos Integrados Carlos Etchart Sales Support Specialist IBM Está IT listo para el Cambio? New server spending Power & cooling costs Server mgmt & admin costs 2013
More informationCOMPLEXITY AND COST COMPARISON: CISCO UCS VS. IBM FLEX SYSTEM (REVISED)
COMPLEXITY AND COST COMPARISON: CISCO UCS VS. IBM FLEX SYSTEM (REVISED) Not all IT architectures are created equal. Whether you are updating your existing infrastructure or building from the ground up,
More informationRedpaper. IBM BladeCenter Foundation for Cloud: Integration Guide. Solution overview. Stephen Smith David Watts
Redpaper Stephen Smith David Watts IBM BladeCenter Foundation for Cloud: Integration Guide Solution overview IBM BladeCenter Foundation for Cloud delivers an ideal platform to expedite virtualized computing
More informationPreparation Guide. How to prepare your environment for an OnApp Cloud v3.0 (beta) deployment.
Preparation Guide v3.0 BETA How to prepare your environment for an OnApp Cloud v3.0 (beta) deployment. Document version 1.0 Document release date 25 th September 2012 document revisions 1 Contents 1. Overview...
More informationVirtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V
Virtualizing Microsoft SQL Server 2008 on the Hitachi Adaptable Modular Storage 2000 Family Using Microsoft Hyper-V Implementation Guide By Eduardo Freitas and Ryan Sokolowski February 2010 Summary Deploying
More informationVirtual SAN Design and Deployment Guide
Virtual SAN Design and Deployment Guide TECHNICAL MARKETING DOCUMENTATION VERSION 1.3 - November 2014 Copyright 2014 DataCore Software All Rights Reserved Table of Contents INTRODUCTION... 3 1.1 DataCore
More informationSPEED your path to virtualization.
SPEED your path to virtualization. 2011 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Introducing HP VirtualSystem Chief pillar of
More informationCisco UCS C220 M3 Server
Data Sheet Cisco UCS C220 M3 Rack Server Product Overview The Cisco Unified Computing System (Cisco UCS) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking and storage
More informationBosch Video Management System High Availability with Hyper-V
Bosch Video Management System High Availability with Hyper-V en Technical Service Note Bosch Video Management System Table of contents en 3 Table of contents 1 Introduction 4 1.1 General Requirements
More informationIVA & UCS. Frank Stott UCS Sales Specialist frstott@cisco.com. 2010 Cisco and/or its affiliates. All rights reserved.
IVA & UCS Frank Stott UCS Sales Specialist frstott@cisco.com 2010 Cisco and/or its affiliates. All rights reserved. 1 Presented jointly by Cisco, NetApp, and VMware 2010 Cisco and/or its affiliates. All
More informationCisco UCS B-Series M2 Blade Servers
Cisco UCS B-Series M2 Blade Servers Cisco Unified Computing System Overview The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and
More informationHP Virtual Connect. Tarass Vercešuks / 3 rd of October, 2013
HP Virtual Connect Tarass Vercešuks / 3 rd of October, 2013 Trends Creating Data Center Network Challenges Trends 2 Challenges Virtualization Complexity Cloud Management Consumerization of IT Security
More informationIBM Flex System Manager IBM Redbooks Product Guide
IBM Flex System Manager IBM Redbooks Product Guide IBM Flex System Manager (FSM) is a systems management appliance that drives efficiency and cost savings in the data center. IBM Flex System Manager provides
More informationCisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
More informationBest Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server
Best Practices Guide: Network Convergence with Emulex LP21000 CNA & VMware ESX Server How to deploy Converged Networking with VMware ESX Server 3.5 Using Emulex FCoE Technology Table of Contents Introduction...
More informationPowerLinux introduction
PowerLinux introduction Course materials may not be reproduced in whole or in part without the prior written permission of IBM. 9.0 Unit objectives After completing this unit, you should be able to: Recognize
More informationCloud Optimize Your IT
Cloud Optimize Your IT Windows Server 2012 The information contained in this presentation relates to a pre-release product which may be substantially modified before it is commercially released. This pre-release
More informationData Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster
More informationIntel Cluster Ready Appro Xtreme-X Computers with Mellanox QDR Infiniband
Intel Cluster Ready Appro Xtreme-X Computers with Mellanox QDR Infiniband A P P R O I N T E R N A T I O N A L I N C Steve Lyness Vice President, HPC Solutions Engineering slyness@appro.com Company Overview
More informationHUAWEI Tecal E9000 Converged Infrastructure Blade Server
E9000 Converged Infrastructure Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The E9000 is a new-generation blade server that integrates computing, storage, switching,
More informationBoas Betzler. Planet. Globally Distributed IaaS Platform Examples AWS and SoftLayer. November 9, 2015. 20014 IBM Corporation
Boas Betzler Cloud IBM Distinguished Computing Engineer for a Smarter Planet Globally Distributed IaaS Platform Examples AWS and SoftLayer November 9, 2015 20014 IBM Corporation Building Data Centers The
More informationHUS-IPS-5100S(D)-E (v.4.2)
Honeywell s HUS-IPS-5100S(D)-E is a controller-based IP SAN unified storage appliance. Designed for centralized mass data storage, this IP SAN solution can be used with the high performance streaming server
More informationEvaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation
Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation Evaluation report prepared under contract with HP Executive Summary The computing industry is experiencing an increasing demand for
More informationNEC EXPRESS5800/R320c-E4 Configuration Guide
NEC EXPRESS5800/R320c-E4 Configuration Guide VMware model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure
More informationConfiguration Maximums
Topic Configuration s VMware vsphere 5.0 When you select and configure your virtual and physical equipment, you must stay at or below the maximums supported by vsphere 5.0. The limits presented in the
More informationDirect Attached Storage
, page 1 Fibre Channel Switching Mode, page 1 Configuring Fibre Channel Switching Mode, page 2 Creating a Storage VSAN, page 3 Creating a VSAN for Fibre Channel Zoning, page 4 Configuring a Fibre Channel
More informationIBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack and tower servers 2 IBM System x family brochure IBM System x servers Highlights IBM System x and BladeCenter servers
More informationHyperscale Use Cases for Scaling Out with Flash. David Olszewski
Hyperscale Use Cases for Scaling Out with Flash David Olszewski Business challenges Performanc e Requireme nts Storage Budget Balance the IT requirements How can you get the best of both worlds? SLA Optimized
More informationIBM Storwize V7000 Midrange Disk System
IBM Storwize V7000 Midrange Disk System Most powerful and easy-to-use innovative midrange disk system in the storage marketplace Highlights IBM Storwize V7000 delivers sophisticated enterprise-class storage
More informationHP10 Gb Netzwerk. Copyright 2011 Hewlett-Packard GmbH
HP10 Gb Netzwerk 1 10Gb Netzwerk Industrie Standard Server Für eine 10Gb LAN Verbindung zwischen Server und Switch werden: Menge Produkt-Nr Beschreibung Listenpreis Summe Switch 2x 455883-B21 10Gb Short
More information