2.9. Ex-Linear light fitting with metal housing for surface mounting. AB 12 LED / AB 12 E / AB 12 C (Zone 1, 2, 21, 22)

Size: px
Start display at page:

Download "2.9. Ex-Linear light fitting with metal housing for surface mounting. AB 12 LED / AB 12 E / AB 12 C (Zone 1, 2, 21, 22)"

Transcription

1 .9 Ex-Linear light fitting with metal housing for surface mounting AB 1 LED / AB 1 E / AB 1 C (Zone 1,, 1, ) The robust lighting concept for hazardous areas With its flameproof housing made of copper free aluminium (Cu < 0.1 %), high degree of protection IP67 and a protective tube made of borosilicate glass with a high mechanical and thermal stability, this luminaire is the ideal solution for harsh and hazardous environments. The luminaire for all types of applications The AB 1 luminaire series with G13 sockets for fluorescent lamps are either fitted with electronic (AB 1.. E) or electromagnetic ballasts (AB 1.. C). The AB1LED series is intended for use with LED tubes for direct connection without ballast operation. The easy-to-open threaded cover, the large terminal compartment and the lamp assembly on a guide carriage facilitate servicing. An optional external reflector ensures an application-specific light distribution. The optional protective wire guard made of stainless steel provides added safety. Features Robust Ex-d housing For fluorescent lamps or LED-tubes Easy opening due to screw cover on end individual circuits (double lamp version) Large terminal compartment High degree of protection IP EATON

2 Ordering details AB 1 LED / AB 1 E / AB 1 C.9 Ordering details Type Content Terminals Throughwiring single-ended Cable gland/ thread AB 1 LED for retrofit LED-tubes AB 10 LED1E AB 140 LED1E AB 165 LED1E AB 10 LED1E AB 140 LED1E AB 165 LED1E AB 1 E with electronic ballast (EVG) AB 10 E ( x 18 W) AB 140 E ( x 36 W) AB 165 E ( x 58 W) AB 10 E ( x 18 W) AB 140 E ( x 36 W) AB 165 E ( x 58 W) Scope of delivery without lamp and fixing accessories Metal cable glands see catalogue part :.3.1 ff Threaded plug Order No. 1 x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR EATON 1..69

3 .9 Ordering details / Accessories AB1 Ordering details Type Content Terminals Throughwiring single-ended AB 1 C with electro-magnetic ballast AB 10 C ( x 18/0 W) AB 140 C ( x 36/40 W) AB 165 C ( x 58/65 W) AB 10 C ( x 18/0 W) AB 140 C ( x 36/40 W) AB 165 C ( x 58/65 W) AB 1 PL for PL-lamps AB 136 PL ( x 36 W PL) AB 136 PL ( x 36 W PL) Scope of delivery without lamp and fixing accessories Metal cable glands see catalogue part :.3.1 ff Cable gland/ thread Threaded plug Order No. 1 x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x 3/4'' Ex-d NOR Accessories Type Content Application Order No. LED tube 9 W 600 mm 1100 lm / 840 AB 10 LED 1E LED tube 18 W 100 mm 300 lm / 840 AB 140 LED 1E LED tube 7 W 1500 mm 3400 lm / 840 AB 165 LED 1E Accessories Type Content Application Order No. Reflector RAB 0 Reflector, AISI 304 for AB 10. / AB 136 PL NOR Reflector RAB 40 Reflector, AISI 304 for AB NOR Reflector RAB 65 Reflector, AISI 304 for AB NOR Reflector GRAB 0 Reflector + wire guard ANSI 304 for AB 10../AB 136 PL NOR Reflector GRAB 40 Reflector + wire guard ANSI 304 for AB NOR Reflector GRAB 65 Reflector + wire guard ANSI 304 for AB NOR Reflector RAB 0 Reflector, AISI 316 for AB 10../AB 136 PL NOR Reflector RAB 40 Reflector, AISI 316 for AB 140 NOR Reflector RAB 65 Reflector, AISI 316 for AB 165 NOR Reflector GRAB 0 Reflector + wire guard ANSI 316 for AB 10../AB 136 PL NOR Reflector GRAB 40 Reflector + wire guard ANSI 316 for AB NOR Reflector GRAB 65 Reflector + wire guard ANSI 316 for AB 165 NOR EATON

4 Dimension drawing / Polar curve AB 1 LED / AB 1 E / AB 1 C.9 Polar curve AB 1...LED/E/C AB Reflector RAB C 0 C l/cd/klm Reflector with wire guard GRAB Wiring diagram AB 1... LED 1 E 114 L PE N Type AB 1 LED 1 E optional entries, on request entries A B M8x1mm A B AB AB AB AB 136 PL Dimensions in mm EATON 1..71

5 .9 Technical data AB1 / AB 1 LED Technical data AB 1 LED AB1 E EC-Type Examination Certificate LOM 0 ATEX 013 X LOM 0 ATEX 013 X IECEx Certificate of Conformity IECEx BKI X Marking accd. to 94/9/EC D II G Ex d IIB T6 Gb D II D Ex t IIIC T85 C Db D II G Ex d IIB T5 Gb D II D Ex t IIIC T76 C/T93 C Db Marking accd. to IECEx Ex d IIB T5 /Ex d IIC T5 Ex td A1 IP67 T76 C Permissible ambient temperature -0 C up to +40 C (T6) -0 C up to + 40 C Rated voltage max. 77 V 198 V - 54 V AC 175 V - 80 V DC Frequency Hz 50/60 Hz Power factor cos Circuit direct EVG Protection class I I Lamp / Illuminant x T8 LED-tube 9-5 W or x T6 / W x T8 LED-tube up to 50 W, both ends supply voltage (Retrofit) Lamp cap G13 accd. to IEC G13 accd. to IEC Light output ratio 90 % 73% Connecting terminals L, N and PE: x, 5 mm² / PE ext. x 6 mm² L1, N and PE: x.5 mm / PE ext. x 6 mm Enclosure colour grey grey Enclosure material copper-free aluminium with powder coating copper-free aluminium with powder coating Cable glands / gland plates / enclosure drilling direct entry: x 3/4 NPT or x M5 1 x Ex-d blanking plug 3/4 or M5 direct entry: x 3/4 NPT or x M5 1 x Ex-d blanking plug 3/4 or M5 Degree of protection accd. to EN 6059 IP67 IP67 Protective cover / protective bowl borosilicate glass borosilicate glass 1..7 EATON

6 Technical data AB1 C.9 Technical data EC-Type Examination Certificate IECEx Certificate of Conformity AB1 C LOM 0 ATEX 013 X IECEx BKI X Marking accd. to 94/9/EC D II G Ex d IIB T5 Gb D II D Ex t IIIC T76 C/T93 C Db Marking accd. to IECEx Ex d IIB T5 / Ex d IIC T5 Ex td A1 IP67 T93 C Permissible ambient temperature -0 C up to +55 C Rated voltage 30 V Frequency 50 Hz Power factor cos 0.9 Circuit conventional ballast with ignitor Protection class I Lamp / Illuminant x T6 / W Lamp cap G13 accd. to IEC Light output ratio 70 % Connecting terminals L1, N and PE: x.5 mm / PE ext. x 6 mm Enclosure colour grey Enclosure material copper-free aluminium with powder coating Cable glands / gland plates / enclosure drilling Degree of protection accd. to EN 6059 Protective cover / protective bowl direct entry: x 3/4 NPT or x M 5 1 x Ex-d blanking plug 3/4 or M5 IP67 borosilicate glass EATON 1..73

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design .8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel Explosion protection Description Flameproof enclosures BARTEC B or EJB series are designed to be installed in industrial plants, where potential hazardous atmospheres occur. These areas are either classified

More information

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP) Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Flameproof Audible Signal 115 db (A) Series YA90

Flameproof Audible Signal 115 db (A) Series YA90 Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

Control and Distribution Boxes made of Stainless Steel Series 8150

Control and Distribution Boxes made of Stainless Steel Series 8150 www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin

More information

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications Applications Powerful, efficient floodlights for large areas such as industrial complexes and ship loading areas. Rated for use in hazardous areas. Features Highly efficient, integrally ballasted floodlight.

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

Abtech Custom Solutions

Abtech Custom Solutions Abtech Custom Solutions Our Philosophy Abtech recognises that not every customer can find a solution to meet their requirements out of a catalogue or off the shelf, and in keeping with the traditions of

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps

Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps The Twin EL series has two reflectors and an adjustable lampholder making it possible to have inversely proportional light distribution

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

DuroSite TM High Bay Lighting

DuroSite TM High Bay Lighting DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically

More information

Safety instructions VEGADIS DIS81.CEIA/V****

Safety instructions VEGADIS DIS81.CEIA/V**** Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application

More information

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands: Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Nightscape High performance floodlights and spotlights for discharge lamps

Nightscape High performance floodlights and spotlights for discharge lamps Nightscape High performance floodlights and spotlights for discharge lamps Nightscape is a range of floodlights and spotlights which offers new possibilities for the architectural illumination of buildings.

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps Nightspot A2 Nightspot A2 Floodlights for LEDs and high pressure discharge lamps Nightspot floodlights are available with rotationally symmetrical reflectors in different sizes for metal halide lamps and

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Terminal Box. Specifications TNCN

Terminal Box. Specifications TNCN Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet

More information

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W Watertight Luminaire, surface, 1x18W / x18w / x4w / 1x36W / x36w / x54w IP67 00 cd/klm 18W 36W 30V/ 50/60Hz 1x18W 5105 0005..-xxx.8 x18w 5105 0001..-xxx 3.8 x4w 5105 0045..-xxx 3.0 x54w 5105 0044..-xxx

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Industrial Linergy LED

Industrial Linergy LED Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility

More information

Superlight Compact Nano

Superlight Compact Nano Willy Meyer+Sohn GmbH+Co. KG Stemmessiepener Weg 5 D-58675 Hemer Telephone: +49 (0) 23 72/98 91-0 Telefax: +49 (0) 23 72/98 91-48 E-mail: info@meyer-lighting.com www.meyer-lighting.com 258 00 530-1211

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Instructions for Safe Use

Instructions for Safe Use Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

REVO-LB. REVO LB (Low Bay Industrial Luminaires) REVO-LB REVO LB (Low Bay Industrial Luminaires) LOW BAY INDUSTRIAL LUMINAIRES The REVO-LB luminaires have been developed as a new series to be used on low ceilings (Low Bay) adding to our successful energy-saving

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

Technical Specifications

Technical Specifications ZCAM3 HAZARDOUS AREA THERMAL IMAGING CAMERAS DS-003 Issue 01 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

STB Series Enclosures

STB Series Enclosures STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard

More information

H45 LED - Direct and indirect pendant

H45 LED - Direct and indirect pendant RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,

More information

Signal Tower modulsignal50

Signal Tower modulsignal50 Signal Tower modulsignal50 S I G N A L G E R Ä T E modulary construction with bayonet locking system fast and easy to operate, mount, configurate and change of modules troublefree and fingersafe bulb change

More information

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex

More information

Nightspot High performance floodlights for discharge lamps and LEDs

Nightspot High performance floodlights for discharge lamps and LEDs Nightspot High performance floodlights for discharge lamps and LEDs Design: Roy Fleedwood The Nightspot series of floodlights comes in three sizes and with rotationally symmetrical reflectors: - Nightspot

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

TEIP11 I/P signal converter for standard signals. Measurement made easy

TEIP11 I/P signal converter for standard signals. Measurement made easy Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

1756 ControlLogix Chassis Specifications

1756 ControlLogix Chassis Specifications Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,

More information

Explosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60

Explosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60 www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas Brochure Light fittings, floodlights and beacons New LED range for hazardous areas 2 ABB DTS - New LED range for hazardous areas LIT-140GB-LED Introduction LED: Save time, money and energy ABB DTS new

More information

Connection technology from ifm.

Connection technology from ifm. Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Dimensions. LUC-M20 with F12 housing and process connection 2 approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions. Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning

More information

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 752 FOUNDATION fieldbus Remote Indicator Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional

More information

Software and Display instruments

Software and Display instruments Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

Fluxa Area floodlights for high pressure discharge lamps and LEDs

Fluxa Area floodlights for high pressure discharge lamps and LEDs Fluxa Area floodlights for high pressure discharge lamps and s Fluxa is a series of area floodlights with symmetrical or wide beam reflectors. There are 4 sizes for high pressure discharge lamps or with

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed

More information

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS 1 st Edition 29 th November 2013 Table of content a. Disclaimer... 3 b. Introduction... 3 c. Summary check lists for components...

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany

RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX 505 RESOLUX 650 RESOLUX 720 / 730 / 750 Application Suitable for high switching frequencies as

More information

13 SERIES. Electronic step relays 10-16 A 13.81 13.91

13 SERIES. Electronic step relays 10-16 A 13.81 13.91 13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Acclaim III Recessed Fluorescent Luminaires ATEX

Acclaim III Recessed Fluorescent Luminaires ATEX Acclaim III Recessed Fluorescent Luminaires ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment.

More information