2.9. Ex-Linear light fitting with metal housing for surface mounting. AB 12 LED / AB 12 E / AB 12 C (Zone 1, 2, 21, 22)
|
|
- Jade Amberly Martin
- 7 years ago
- Views:
Transcription
1 .9 Ex-Linear light fitting with metal housing for surface mounting AB 1 LED / AB 1 E / AB 1 C (Zone 1,, 1, ) The robust lighting concept for hazardous areas With its flameproof housing made of copper free aluminium (Cu < 0.1 %), high degree of protection IP67 and a protective tube made of borosilicate glass with a high mechanical and thermal stability, this luminaire is the ideal solution for harsh and hazardous environments. The luminaire for all types of applications The AB 1 luminaire series with G13 sockets for fluorescent lamps are either fitted with electronic (AB 1.. E) or electromagnetic ballasts (AB 1.. C). The AB1LED series is intended for use with LED tubes for direct connection without ballast operation. The easy-to-open threaded cover, the large terminal compartment and the lamp assembly on a guide carriage facilitate servicing. An optional external reflector ensures an application-specific light distribution. The optional protective wire guard made of stainless steel provides added safety. Features Robust Ex-d housing For fluorescent lamps or LED-tubes Easy opening due to screw cover on end individual circuits (double lamp version) Large terminal compartment High degree of protection IP EATON
2 Ordering details AB 1 LED / AB 1 E / AB 1 C.9 Ordering details Type Content Terminals Throughwiring single-ended Cable gland/ thread AB 1 LED for retrofit LED-tubes AB 10 LED1E AB 140 LED1E AB 165 LED1E AB 10 LED1E AB 140 LED1E AB 165 LED1E AB 1 E with electronic ballast (EVG) AB 10 E ( x 18 W) AB 140 E ( x 36 W) AB 165 E ( x 58 W) AB 10 E ( x 18 W) AB 140 E ( x 36 W) AB 165 E ( x 58 W) Scope of delivery without lamp and fixing accessories Metal cable glands see catalogue part :.3.1 ff Threaded plug Order No. 1 x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR EATON 1..69
3 .9 Ordering details / Accessories AB1 Ordering details Type Content Terminals Throughwiring single-ended AB 1 C with electro-magnetic ballast AB 10 C ( x 18/0 W) AB 140 C ( x 36/40 W) AB 165 C ( x 58/65 W) AB 10 C ( x 18/0 W) AB 140 C ( x 36/40 W) AB 165 C ( x 58/65 W) AB 1 PL for PL-lamps AB 136 PL ( x 36 W PL) AB 136 PL ( x 36 W PL) Scope of delivery without lamp and fixing accessories Metal cable glands see catalogue part :.3.1 ff Cable gland/ thread Threaded plug Order No. 1 x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x 3/4'' Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x M5 Ex-d NOR x 3/4'' Ex-d NOR Accessories Type Content Application Order No. LED tube 9 W 600 mm 1100 lm / 840 AB 10 LED 1E LED tube 18 W 100 mm 300 lm / 840 AB 140 LED 1E LED tube 7 W 1500 mm 3400 lm / 840 AB 165 LED 1E Accessories Type Content Application Order No. Reflector RAB 0 Reflector, AISI 304 for AB 10. / AB 136 PL NOR Reflector RAB 40 Reflector, AISI 304 for AB NOR Reflector RAB 65 Reflector, AISI 304 for AB NOR Reflector GRAB 0 Reflector + wire guard ANSI 304 for AB 10../AB 136 PL NOR Reflector GRAB 40 Reflector + wire guard ANSI 304 for AB NOR Reflector GRAB 65 Reflector + wire guard ANSI 304 for AB NOR Reflector RAB 0 Reflector, AISI 316 for AB 10../AB 136 PL NOR Reflector RAB 40 Reflector, AISI 316 for AB 140 NOR Reflector RAB 65 Reflector, AISI 316 for AB 165 NOR Reflector GRAB 0 Reflector + wire guard ANSI 316 for AB 10../AB 136 PL NOR Reflector GRAB 40 Reflector + wire guard ANSI 316 for AB NOR Reflector GRAB 65 Reflector + wire guard ANSI 316 for AB 165 NOR EATON
4 Dimension drawing / Polar curve AB 1 LED / AB 1 E / AB 1 C.9 Polar curve AB 1...LED/E/C AB Reflector RAB C 0 C l/cd/klm Reflector with wire guard GRAB Wiring diagram AB 1... LED 1 E 114 L PE N Type AB 1 LED 1 E optional entries, on request entries A B M8x1mm A B AB AB AB AB 136 PL Dimensions in mm EATON 1..71
5 .9 Technical data AB1 / AB 1 LED Technical data AB 1 LED AB1 E EC-Type Examination Certificate LOM 0 ATEX 013 X LOM 0 ATEX 013 X IECEx Certificate of Conformity IECEx BKI X Marking accd. to 94/9/EC D II G Ex d IIB T6 Gb D II D Ex t IIIC T85 C Db D II G Ex d IIB T5 Gb D II D Ex t IIIC T76 C/T93 C Db Marking accd. to IECEx Ex d IIB T5 /Ex d IIC T5 Ex td A1 IP67 T76 C Permissible ambient temperature -0 C up to +40 C (T6) -0 C up to + 40 C Rated voltage max. 77 V 198 V - 54 V AC 175 V - 80 V DC Frequency Hz 50/60 Hz Power factor cos Circuit direct EVG Protection class I I Lamp / Illuminant x T8 LED-tube 9-5 W or x T6 / W x T8 LED-tube up to 50 W, both ends supply voltage (Retrofit) Lamp cap G13 accd. to IEC G13 accd. to IEC Light output ratio 90 % 73% Connecting terminals L, N and PE: x, 5 mm² / PE ext. x 6 mm² L1, N and PE: x.5 mm / PE ext. x 6 mm Enclosure colour grey grey Enclosure material copper-free aluminium with powder coating copper-free aluminium with powder coating Cable glands / gland plates / enclosure drilling direct entry: x 3/4 NPT or x M5 1 x Ex-d blanking plug 3/4 or M5 direct entry: x 3/4 NPT or x M5 1 x Ex-d blanking plug 3/4 or M5 Degree of protection accd. to EN 6059 IP67 IP67 Protective cover / protective bowl borosilicate glass borosilicate glass 1..7 EATON
6 Technical data AB1 C.9 Technical data EC-Type Examination Certificate IECEx Certificate of Conformity AB1 C LOM 0 ATEX 013 X IECEx BKI X Marking accd. to 94/9/EC D II G Ex d IIB T5 Gb D II D Ex t IIIC T76 C/T93 C Db Marking accd. to IECEx Ex d IIB T5 / Ex d IIC T5 Ex td A1 IP67 T93 C Permissible ambient temperature -0 C up to +55 C Rated voltage 30 V Frequency 50 Hz Power factor cos 0.9 Circuit conventional ballast with ignitor Protection class I Lamp / Illuminant x T6 / W Lamp cap G13 accd. to IEC Light output ratio 70 % Connecting terminals L1, N and PE: x.5 mm / PE ext. x 6 mm Enclosure colour grey Enclosure material copper-free aluminium with powder coating Cable glands / gland plates / enclosure drilling Degree of protection accd. to EN 6059 Protective cover / protective bowl direct entry: x 3/4 NPT or x M 5 1 x Ex-d blanking plug 3/4 or M5 IP67 borosilicate glass EATON 1..73
2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design
.8 Ex-Recess-mounted, ceiling emergency light fittings in compact metal design RLF/RLF-INOX 50 18-58 W / RLF/RLF-INOX 50... N 18-36 W (Zone 1,, 1, ) The explosion-protected lighting concept for clean rooms
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationEXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES
EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationCompact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationIIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel
Explosion protection Description Flameproof enclosures BARTEC B or EJB series are designed to be installed in industrial plants, where potential hazardous atmospheres occur. These areas are either classified
More informationTerminal Boxes in Glass Fiber Reinforced Polyester (GRP)
Features Variants options Glass fiber reinforced polyester (GRP) enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 16 enclosure size options Various terminal
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationFlameproof Audible Signal 115 db (A) Series YA90
Clifford Snell www.stahl.de > Max sound output 115 db (A) / 1 m > 2 stage alarm, independently selectable 2nd stage > IP66 rated as standard > 32 selectable tones meeting international regulations > Light
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationControl and Distribution Boxes made of Stainless Steel Series 8150
www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationHID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications
Applications Powerful, efficient floodlights for large areas such as industrial complexes and ship loading areas. Rated for use in hazardous areas. Features Highly efficient, integrally ballasted floodlight.
More informationTechnical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
More informationAbtech Custom Solutions
Abtech Custom Solutions Our Philosophy Abtech recognises that not every customer can find a solution to meet their requirements out of a catalogue or off the shelf, and in keeping with the traditions of
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationExplosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
More informationTechnical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationTwin EL Wall luminaires for halogen lamps or ceramic metal halide lamps
Twin EL Wall luminaires for halogen lamps or ceramic metal halide lamps The Twin EL series has two reflectors and an adjustable lampholder making it possible to have inversely proportional light distribution
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationDuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
More informationSafety instructions VEGADIS DIS81.CEIA/V****
Safety instructions VEGADIS DIS81.CEIA/V**** CSA 14.2662675 Ex d IIC T6 T1 Gb 0044 Document ID: 48926 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
More informationSafety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More informationSITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
More informationMaterial: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:
Oil & Gas / Heavy Industry EX-Proof Stainless Steel Shaft Encoder - Ø 68 mm Shaft - Ø 10 mm to Ø 5/8 inch Resolution up to 10,000 ppr IP 66 (IP 67 option) ATEX certified EX-Proof IECEx certified EX-Proof
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationNightscape High performance floodlights and spotlights for discharge lamps
Nightscape High performance floodlights and spotlights for discharge lamps Nightscape is a range of floodlights and spotlights which offers new possibilities for the architectural illumination of buildings.
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationComponents for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
More informationNightspot A2 Floodlights for LEDs and high pressure discharge lamps
Nightspot A2 Nightspot A2 Floodlights for LEDs and high pressure discharge lamps Nightspot floodlights are available with rotationally symmetrical reflectors in different sizes for metal halide lamps and
More informationPlastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationTerminal Box. Specifications TNCN
Terminal box The /TNCC range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main body is manufactured from minimum 1,5 mm sheet
More informationWatertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W
Watertight Luminaire, surface, 1x18W / x18w / x4w / 1x36W / x36w / x54w IP67 00 cd/klm 18W 36W 30V/ 50/60Hz 1x18W 5105 0005..-xxx.8 x18w 5105 0001..-xxx 3.8 x4w 5105 0045..-xxx 3.0 x54w 5105 0044..-xxx
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationIndustrial Linergy LED
Eaton s commitment to supplying energy saving innovative products is the driving force behind. follows in the tradition of highly efficient large space luminaires which have the performance and flexibility
More informationSuperlight Compact Nano
Willy Meyer+Sohn GmbH+Co. KG Stemmessiepener Weg 5 D-58675 Hemer Telephone: +49 (0) 23 72/98 91-0 Telefax: +49 (0) 23 72/98 91-48 E-mail: info@meyer-lighting.com www.meyer-lighting.com 258 00 530-1211
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationInstructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationStainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationREVO-LB. REVO LB (Low Bay Industrial Luminaires)
REVO-LB REVO LB (Low Bay Industrial Luminaires) LOW BAY INDUSTRIAL LUMINAIRES The REVO-LB luminaires have been developed as a new series to be used on low ceilings (Low Bay) adding to our successful energy-saving
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
More informationTechnical Specifications
ZCAM3 HAZARDOUS AREA THERMAL IMAGING CAMERAS DS-003 Issue 01 ZIZCAM Ltd are a UK based manufacturer of CCTV Cameras for use in the Hazardous Oil, Gas and Petrochemical industries. Consequently our products
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationFlow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
More informationSTB Series Enclosures
STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard
More informationH45 LED - Direct and indirect pendant
RAL 01 10 00 IP 20 230V 50/60Hz Specifications Direct and indirect light pendant linear luminaire. Aluminium profile. Diffusers in frosted polycarbonate profile. Driver included. Supplied with clear base,
More informationSignal Tower modulsignal50
Signal Tower modulsignal50 S I G N A L G E R Ä T E modulary construction with bayonet locking system fast and easy to operate, mount, configurate and change of modules troublefree and fingersafe bulb change
More informationEX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
More informationNightspot High performance floodlights for discharge lamps and LEDs
Nightspot High performance floodlights for discharge lamps and LEDs Design: Roy Fleedwood The Nightspot series of floodlights comes in three sizes and with rotationally symmetrical reflectors: - Nightspot
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
More informationOperating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
More informationTEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
More informationDisabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions
Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of
More information97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
More information1756 ControlLogix Chassis Specifications
Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,
More informationExplosion Proof Combination Signal - 110 db (A) / 5 Joule Series YL60
www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationBrochure. Light fittings, floodlights and beacons New LED range for hazardous areas
Brochure Light fittings, floodlights and beacons New LED range for hazardous areas 2 ABB DTS - New LED range for hazardous areas LIT-140GB-LED Introduction LED: Save time, money and energy ABB DTS new
More informationConnection technology from ifm.
Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationDimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
More informationRosemount 752 FOUNDATION fieldbus Remote Indicator
Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional
More informationSoftware and Display instruments
Software and Display instruments 272 Overview Software and Display instruments 276 VEGA Inventory System 278 DTM Collection und PACTware 279 VEGACONNECT 280 PLICSCOM, PLICSLED 282 VEGADIS 81, 82, 176 271
More information3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
More informationFluxa Area floodlights for high pressure discharge lamps and LEDs
Fluxa Area floodlights for high pressure discharge lamps and s Fluxa is a series of area floodlights with symmetrical or wide beam reflectors. There are 4 sizes for high pressure discharge lamps or with
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed
More informationLightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS
LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS 1 st Edition 29 th November 2013 Table of content a. Disclaimer... 3 b. Introduction... 3 c. Summary check lists for components...
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationRESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany
RESOLUX / HIGHLITE/ COMPACT LINE Technology Lighting as its best. Designed and produced in Germany RESOLUX 505 RESOLUX 650 RESOLUX 720 / 730 / 750 Application Suitable for high switching frequencies as
More information13 SERIES. Electronic step relays 10-16 A 13.81 13.91
13 Electronic step relays 10-16 A 13 13.81 - Electronic step relay - Rail mount - 1 Pole 13.91 - Electronic step relay and timing step relay Switch box mount - 1 Pole Fixed time (10 minutes) timing function
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationThermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)
Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured
More informationTurbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
More informationAcclaim III Recessed Fluorescent Luminaires ATEX
Acclaim III Recessed Fluorescent Luminaires ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment.