DCP DC- Series (Soft Launch) 1. Competitive Pricing 2. V6 FCU Selection Software Enabled 3. Lighter In Weight

Size: px
Start display at page:

Download "DCP DC- Series (Soft Launch) 1. Competitive Pricing 2. V6 FCU Selection Software Enabled 3. Lighter In Weight"

Transcription

1 DCP DC- Series (Soft Launch) 1. Competitive Pricing 2. V6 FCU Selection Software Enabled 3. Lighter In Weight 1

2 C Series VS D Series C Series D Series ½ OD Coil 3/8 OD Coil Headline Motor Yongan Motor Torin Fan Torin / Nicotra Fan Slight Dimensional Change from C to D Series 2

3 INTRODUCTION YORK Ducted Direct Drive Fan Coil Air Conditioners are designed to fulfill the air conditioning requirements of today s living. These requirements include dependable trouble-free operation where units will be installed above ceilings and hallways and in closets; compact space-saving design to allow more valuable living space; and the quiet performance affordable by a centrally-located unit that is ducted to individual rooms. Although primarily intended for apartment markets, these versatile units can also be used in low static pressure applications where ducted units are needed. NOMENCLATURE DCP 06 D C Voltage Code: Generation: C 220/240V-1PH-50/60HZ B to Z Size: Product Range: DCP (Blow Through) FEATURES 8 unit sizes offer a wide capacity range from 600 to 2000 nominal CFM. This offer precisely matches most of the room load requirements, assuring maximum performance and operating efficiency. Design for service/maintenance is practiced where coil surface is exposed for easy cleaning and the fan motor assembly could be easily removed for service. Easy removal of filters is kept. Flexible Piping Connection comes along with left / right hand connection at your preference. Special Features Upon Request 1. Double Skin Unit with High IAQ, Reduced Noise Level and Aesthetic Outlook. 2. Heating Coil / Heater requirement. 3. Special Insulation (Thickness / Type) for different applications. 4. Energy Saving VAV couple spare part. 5. Various Coil Fin Materials. 3

4 GUIDE SPECIFICATION General Furnish and install YORK Ducted Model Fan Coil air conditioners as indicated and scheduled on the plans. Basic Unit And Cabinet The basic unit shall be fabricated of GI sheet to JIS G All cabinet units shall be acoustically and thermally insulated with polyethylene foam insulation. Coil Coils shall be a minimum of three rows and have 3/8 inch OD copper tubes with aluminium fins mechanically bonded to the tubes. All coils shall be fitted with access valve. Coils should be factory leak-tested at 350 psig and suitable for working pressure to 250 psig. Capacity rating is ensured in accordance to ARI 410. Motor High Performance motor shall be 3 speeds, permanent split capacitor type, with UL listed thermal overload protection. Motor bearings shall be of ball bearing type. Fan Fan shall be of the centrifugal, forward-curved type. Fan wheels shall be statically and dynamically balanced. Fan wheels and housings shall be galvanized steel. Unit sizes shall have one motor and one fan. Unit sizes shall have two motors and two fans. Drain Pan All models shall have drain pans with oven baked polyester powder coat, exterior surface insulated with polyethylene foam. The drain connection shall be 1 inch OD steel pipe. Condensate pans shall be not less than 1 inch deep and shall extend completely under the coil and return bends. Filters Washable Synthetic Fiber filters. 4

5 SPECIFICATIONS( 3 ROW COIL) MODEL DCP 06-DC DCP 08-DC DCP 10-DC DCP 12-DC DCP 14-DC DCP 16-DC DCP 18-DC DCP 20-DC Airflow (Medium Speed) Total Cooling Capacity Water Flow Rate Head Loss COIL Type Number of Rows / FPI Tube Face Area m 3 /h CFM Btu/hr kw usgpm l/s maq ft.wg Seamless Copper Tube / Corrugated Aluminium Fin 3R / 12 FPI 9.53mm O.D. m ft Face Velocity m/s fpm Max. Working Pressure psig 250 Testing Pressure psig 350 Connection (Copper Tube) 7/8 1-1/8 Piping Direction MOTOR Type Right / Left 3-Speed Permanent Split Capacitor Motor Number of Motor Rating Output (per unit motor) watt RLA(240V/1ph/50Hz) (per unit motor) A Poles 6 FAN Type Centrifugal Fan (Forward-Curved Steel Fan Wheels) Blower Size (Qty) DD 9 x 7 (1) DD 9 x 9 (1) DD 9 x 9 (1) DD 9 x 7 (2) DD 9 x 7 (2) DD 9 x 9 (2) DD 9 x 9 (2) DD 9 x 9 (2) FRAME Casing Insulation DRAIN PAN Material Finishing Connection DIMENSION (REAR PLENUM) Galvanized Steel Polyethylene Foam : 6mm Galvanized Steel Epoxy Polyester Powder Coating 32mm O.D. Steel Pipe Depth mm Width mm Height mm UNIT WEIGHT (DRY COIL) 3 Rows Coil Unit kg

6 SPECIFICATIONS(4 ROW COIL) MODEL DCP 06-DC DCP 08-DC DCP 10-DC DCP 12-DC DCP 14-DC DCP 16-DC DCP 18-DC DCP 20-DC Airflow (Medium Speed) Total Cooling Capacity Water Flow Rate Head Loss COIL Type Number of Rows / FPI Tube Face Area m 3 /h CFM Btu/hr kw usgpm l/s maq ft.wg Seamless Copper Tube / Corrugated Aluminium Fin 4 Rows / 12 FPI 9.53mm O.D. m ft Face Velocity m/s fpm Max. Working Pressure psig 250 Testing Pressure psig 350 Connection (Copper Tube) 7/8 1-1/8 1-3/8 Piping Direction MOTOR Type Right / Left 3-Speed Permanent Split Capacitor Motor Number of Motor Rating Output (per unit motor) watt RLA(240V/1ph/50Hz) (per unit motor) A Poles 6 FAN Type Centrifugal Fan (Forward-Curved Steel Fan Wheels) Blower Size (Qty) DD 9 x 7 (1) DD 9 x 9 (1) DD 9 x 9 (1) DD 9 x 7 (2) DD 9 x 7 (2) DD 9 x 9 (2) DD 9 x 9 (2) DD 9 x 9 (2) FRAME Casing Insulation DRAIN PAN Material Finishing Connection DIMENSION (REAR PLENUM) Galvanized Steel Polyethylene Foam : 6mm Galvanized Steel Epoxy Polyester Powder Coating 32mm O.D. Steel Pipe Depth mm Width mm Height mm UNIT WEIGHT (DRY COIL) 4 Rows Coil Unit kg

7 SPECIFICATIONS(6 ROW COIL) MODEL DCP 06-DC DCP 08-DC DCP 10-DC DCP 12-DC DCP 14-DC DCP 16-DC DCP 18-DC DCP 20-DC Airflow (Medium Speed) Total Cooling Capacity Water Flow Rate Head Loss COIL Type Number of Rows / FPI Tube Face Area m 3 /h CFM Btu/hr kw usgpm l/s maq ft.wg Seamless Copper Tube / Corrugated Aluminium Fin 6 Row / 12 FPI 9.53mm O.D. m ft Face Velocity m/s fpm Max. Working Pressure psig 250 Testing Pressure psig 350 Connection (Copper Tube) 1-1/8 1-3/8 Piping Direction MOTOR Type Right / Left 3-Speed Permanent Split Capacitor Motor Number of Motor Rating Output (per unit motor) watt RLA(240V/1ph/50Hz) (per unit motor) A Poles 6 FAN Type Centrifugal Fan (Forward-Curved Steel Fan Wheels) Blower Size (Qty) DD 9 x 7 (1) DD 9 x 9 (1) DD 9 x 9 (1) DD 9 x 7 (2) DD 9 x 7 (2) DD 9 x 9 (2) DD 9 x 9 (2) DD 9 x 9 (2) FRAME Casing Insulation DRAIN PAN Material Finishing Connection DIMENSION (REAR PLENUM) Galvanized Steel Polyethylene Foam : 6mm Galvanized Steel Epoxy Polyester Powder Coating 32mm O.D. Steel Pipe Depth mm Width mm Height mm UNIT WEIGHT (DRY COIL) 6 Rows Coil Unit kg

8 NOTES:- The performances are based on the following conditions: Cooling Capacity : -Entering air temperature = C (80 0 F) DB, C (67 0 F)WB -Entering chilled water temperature = C (45 0 F) -Leaving chilled water temperature = C (55 0 F) Airflow: : -Medium fan speed -240V-1Ph-50Hz power supply -Under dry coil condition at 0.2inWg external static pressure -Unit with filters 8

9 ELECTRICAL DATA MODEL: DCP 06, 08, 10DC MODEL: DCP 12, 14, 16DC 9

10 MODEL: DCP 18, 20DC 10

11 AIR DELIVERY (DCP DC SERIES- HIGH STATIC) 4-ROW COIL (240V / 1Ph / 50Hz) WITH FILETR(S) EXTERNAL STATIC PRESSURE - inwg (mmaq) UNIT SIZE MOTOR SPEED 0.20 (5.0) 0.25 (6.4) 0.30 (7.6) 0.35 (9.0) 0.4 (10.2) CFM CMH CFM CMH CFM CMH CFM CMH CFM CMH HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW NOTES: 1. Data compiled are based on units WITH filter(s) 2. Values are based on four row dry coil. 3. For each additional row of dry coil, add 0.05 inwg of static pressure. 4. Wet Coil Conditions occur when the sensible / total heat ratio is 0.91 or less. Wet coil CFM is 92% of dry coil CFM. 5. Units are not suitable to be operated under condition where static pressure is below 0.2 inwg. 11

12 AIR DELIVERY (DCP DC SERIES- HIGH STATIC) 4-ROW COIL (230V / 1Ph / 60Hz) WITH FILTER(S) EXTERNAL STATIC PRESSURE - inwg (mmaq) UNIT SIZE MOTOR SPEED 0.20 (5.0) 0.25 (6.4) 0.30 (7.6) 0.35 (9.0) 0.4 (10.2) CFM CMH CFM CMH CFM CMH CFM CMH CFM CMH HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW NOTES: 1. Data compiled are based on units WITH filter(s) 2. Values are based on four row dry coil. 3. For each additional row of dry coil, add 0.05 inwg of static pressure. 4. Wet Coil Conditions occur when the sensible / total heat ratio is 0.91 or less. Wet coil CFM is 92% of dry coil CFM. 5. Units are not suitable to be operated under condition where static pressure is below 0.2 inwg. 12

13 AIR DELIVERY (DCP DC SERIES- HIGH STATIC) 4-ROW COIL (240V / 1Ph / 50Hz) WITHOUT FILTER(S) EXTERNAL STATIC PRESSURE - inwg (mmaq) UNIT SIZE MOTOR SPEED 0.20 (5.0) 0.25 (6.4) 0.30 (7.6) 0.35 (9.0) 0.4 (10.2) CFM CMH CFM CMH CFM CMH CFM CMH CFM CMH HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW NOTES: 1. Data compiled are based on units WITHOUT filter(s) 2. Values are based on four row dry coil. 3. For each additional row of dry coil, add 0.05 inwg of static pressure. 4. Wet Coil Conditions occur when the sensible / total heat ratio is 0.91 or less. Wet coil CFM is 92% of dry coil CFM. 5. Units are not suitable to be operated under condition where static pressure is below 0.2 inwg. 13

14 AIR DELIEVERY (DCP DC SERIES- HIGH STATIC) 4-ROW COIL (230V / 1Ph / 60Hz) WITHOUT FILTER(S) EXTERNAL STATIC PRESSURE - inwg (mmaq) UNIT SIZE MOTOR SPEED 0.20 (5.0) 0.25 (6.4) 0.30 (7.6) 0.35 (9.0) 0.4 (10.2) CFM CMH CFM CMH CFM CMH CFM CMH CFM CMH HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW HIGH MEDIUM LOW NOTES: 1. Data compiled are based on units WITHOUT filter(s) 2. Values are based on four row dry coil. 3. For each additional row of dry coil, add 0.05 inwg of static pressure. 4. Wet Coil Conditions occur when the sensible / total heat ratio is 0.91 or less. Wet coil CFM is 92% of dry coil CFM. 5. Units are not suitable to be operated under condition where static pressure is below 0.2 inwg. 14

15 COOLING CAPACITY - 3 ROW COIL ENTERING WATER TEMPERATURE 40 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 15

16 COOLING CAPACITY - 3 ROW COIL ENTERING WATER TEMPERATURE 45 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 16

17 COOLING CAPACITY - 3 ROW COIL ENTERING WATER TEMPERATURE 50 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 17

18 COOLING CAPACITY - 4 ROW COIL ENTERING WATER TEMPERATURE 40 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 18

19 COOLING CAPACITY - 4 ROW COIL ENTERING WATER TEMPERATURE 45 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 19

20 COOLING CAPACITY - 4 ROW COIL ENTERING WATER TEMPERATURE 50 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 20

21 COOLING CAPACITY - 6 ROW COIL ENTERING WATER TEMPERATURE 40 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 21

22 COOLING CAPACITY - 6 ROW COIL ENTERING WATER TEMPERATURE 45 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH NOTES: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 22

23 COOLING CAPACITY - 6 ROW COIL ENTERING WATER TEMPERATURE 50 0 F UNIT 76/65 78/65 80/67 82/67 82/69 SIZE GPM PD TH SH TH SH TH SH TH SH TH SH Notes: 1. Total Heat (TH) and Sensible Heat (SH) are expressed in MBH. 2. Pressure Drop (PD) is given in Feet of Water. 3. Water Temperature Rise = Total MBH / (0.5 x GPM) 23

24 COIL CONNECTIONS MODEL HDR CON.(OD-inch) ROW A (mm) B (mm) C (mm) D (mm) E (mm) DCP 06-10DC 7/8 DCP 12-20DC 1-1/ DCP 06-10DC 1-1/8 DCP 12-14DC 1-1/ DCP 16-20DC 1-3/8 350 DCP 06-10DC 1-1/8 DCP 12-20DC 1-3/ Note.: + 10mm 24

25 SHOPFLOOR (DCP DC Series) 25

26 UNIT SIZE DIMENSIONS (MM) ROW A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) FILTER SIZE 340 X 520 X X 650 X X 750 X X 880 X X 505 X X 565 X X 630 X X 680 X 22 26

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Manual CLIFC Fan & Coil Variable Speed Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation

More information

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14 Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Chilled Water Fan Coil Unit

Chilled Water Fan Coil Unit Chilled Water Fan Unit Model: HFCF02~HFCF14 Airflow Range: 200~2400m 3 /h Features and Benefits The Best Choice for Comfort The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal

More information

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way

More information

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Greensource iseries HY Model Unitary Air Handler/Fan Coil Engineering Submittal Sheet Overview Model Nomenclature HY 035 00-1 HY - HYDRONIC AIR HANDLER NOMINAL CAPACITY IN THOUSANDS OF BTUH VOLTAGE DESIGNATION 1 = 208-230/1/60 ELECTRIC HEAT KW 00 - NO ELECTRIC

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost

More information

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as: CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living

More information

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS

More information

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

catalog Single Package Vertical Air Conditioners and Heat Pumps

catalog Single Package Vertical Air Conditioners and Heat Pumps catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs. COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions. LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use

More information

TWE+TTA TWE+TWA 6.25-20 T.R.

TWE+TTA TWE+TWA 6.25-20 T.R. TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES

More information

Contents and Nomenclature

Contents and Nomenclature DX Coils Contents and Nomenclature Nomenclature... 1 Evaporator Coil Types EN... 2 EF... 2 ER... 2 EJ... 3 EK... 3 Evaporator Construction Connections... 4 Tubing... 4 Headers... 5 Tube Supports... 5 Coil

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.

A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment. SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.

More information

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

Innovent LASER Packaged Fresh Air Conditioning Units

Innovent LASER Packaged Fresh Air Conditioning Units LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent

More information

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44. FORM NO. O11-608 REV. 2 Supersedes Form No. O11-608 Rev. 1 OIL FURNACES CLASSIC PREMIUM CLASS UPF OIL FURNACES ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.30 kw] The Rheem Classic

More information

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS FOR COOLERS ABOVE +34ºF Low silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 BTU/HR./10ºF TD LSA LSE, LSR & LST FOR COOLERS AND FREEZERS FROM -20ºF TO +34ºF Low silhouette, draw

More information

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115

CFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115 Air Circulators High Velocity Floor Fans Circulate Large Volumes of Air Product Specifications Size Spd HP HZ CFM/WATT @.0 SP AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

SECTION 15732 AIR CONDITIONING UNIT

SECTION 15732 AIR CONDITIONING UNIT SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration

More information

QUICKAIRE. Vertical Fan Coils Utility/Closet QUICK SHIPMENT. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.

QUICKAIRE. Vertical Fan Coils Utility/Closet QUICK SHIPMENT. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany. Style W-2 1/14 QUICKAIRE Vertical Fan Coils Utility/Closet QUICK SHIPMENT P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com YOU HAVE A DIRECT LINE TO US! QUICKAIRE Fan/Coil

More information

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL AQV09JA High Wall 9,000 Btu/h Heat Pump Nom Cooling Capacity (Btu/h) 9,000 SEER 20.0 Cool Capacity Range (Btu/h) 3,100 to 11,900 Nom Heating Capacity (Btu/h) 11,950 HSPF 10.0 Heating COP 3.7

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

ROOF TOP MOUNTED Air Handler Specification

ROOF TOP MOUNTED Air Handler Specification ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor

More information

IV. Rear Mount System

IV. Rear Mount System Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

Dehumidification Frequently Asked Questions

Dehumidification Frequently Asked Questions Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful

More information

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling.

SPACE COOLERS. P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com. The leader in packaged Space Cooling. SPACE COOLERS P.O. Box 956 Paoli, PA 19301 (800) 523-7590 FAX (610) 251-0805 www.coilcompany.com The leader in packaged Space Cooling. 2 Table of Contents Description Space Cooler from Coil Company. A

More information

Performance Rating of Room Fan- Coils

Performance Rating of Room Fan- Coils ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

CHILLED WATER DATA ROOM UNITS

CHILLED WATER DATA ROOM UNITS Critical Infrastructure for the World s Leading Data Centers CHILLED WATER DATA ROOM UNITS Downflow Net Sensible Cooling 79 220kW Upflow Net Sensible Cooling 66 206kW A Nortek Company DATA CENTER COOLING

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

Defining Quality. Building Comfort. Heating and Cooling Coils

Defining Quality. Building Comfort. Heating and Cooling Coils Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.

More information

HVAC Systems: Overview

HVAC Systems: Overview HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct

More information

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay Original HVAC Units: Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue Photo Essay One fan motor draws air from the lower section of the unit,

More information

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION 238221 - BLOWER COIL UNITS ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90 6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2

More information

GCS16-024-030-036-048-060

GCS16-024-030-036-048-060 Packaged Unit & Gas Heat 2-5 Ton Capacity 50,000-120,000 Btuh Input Heating Capacity GCS16-024-030-036-048-060 FEATURES Designed for outdoor rooftop or ground level installations Down-flow or horizontal

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

AIR-COOLED CONDENSERS Technical Guide

AIR-COOLED CONDENSERS Technical Guide BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser

More information

Single Package Vertical Air Conditioners. Vert-I-Pak

Single Package Vertical Air Conditioners. Vert-I-Pak Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

Explosion-Proof Electric Unit Heaters

Explosion-Proof Electric Unit Heaters Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,

More information

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01

UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

A. Section includes air conditioning units, controls and control panels.

A. Section includes air conditioning units, controls and control panels. SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes air conditioning units, controls and control panels. 1.2 REFERENCES A. Air-Conditioning, Heating, and

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

CARRIER REFRIGERATION EQUIPMENT AND PARTS

CARRIER REFRIGERATION EQUIPMENT AND PARTS EVAPORATOR COILS CONDENSING UNITS 1/2 Through 80 HP COMPLETE REFRIGERATION PACKAGES AIR DEFROST ELECTRIC DEFROST HOT GAS DEFROST Ceiling Temp Low Height Unit Coolers SW Series Literature No. C 230.0 January,

More information

GCS16 GCS20 WARNING CAUTION

GCS16 GCS20 WARNING CAUTION Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

CB29M Bulletin #490071 February 1996

CB29M Bulletin #490071 February 1996 ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

Local Dealer: www.cebrands.com

Local Dealer: www.cebrands.com Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication

More information

FAN COIL UNIT SOFTWARE User Manual

FAN COIL UNIT SOFTWARE User Manual User Manual Thanks for using Tiba fan coil units' selection software. To start the selection process to software selection there are some steps we need to follow: Front page: 1. Only selection 2. Performance

More information

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Advances in Gas Cooler Design and the New Gas Cooler Product Selector Advances in Gas Cooler Design and the New Gas Cooler Product Selector Simon Jones Engineering Manager Sean Armitage Sales Manager Introduction GEA Searle Over 90 years experience in the design and manufacture

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO. TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled

More information

Basic Nameplate Information

Basic Nameplate Information Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address

More information