Order by phone Order on-line Order by fax Website
|
|
- Dylan McKinney
- 7 years ago
- Views:
Transcription
1 Mettler Toledo, X-mate Pro, Multi-parameter, Meter The X-mate pro is a multi-parameter, portable meter. Consisting of the base unit MX300, to which you can fit a wide choice of sensors. Parameters include conductivity, ph, salinity, TDS, dissolved oxygen, redox, mv, humidity, ISE and temperature. Unique Duo and Trio sensor modules ideal for environmental monitoring are available. These include ph and conductivity, (plus dissolved oxygen on the Trio) all with built-in temperature. Data logging allows you to take automatic readings at time intervals ranging from 1 minute to 24 hours. The memory allows storage of up to 199 readings along with date, time and identification number, which can be downloaded to a PC when convenient parameters GLP Data logging Electrode condition indicator Single handed use reminder Multi-parameter modules Measuring range Conductivity, µs/cm to 1999 Conductivity, ms/cm 2.00 to ph to mv ±1999 Temperature, C 0 to 80.0 Oxygen, % 0.0 to Oxygen, mg/l 0.0 to 20.0 Concentration, ppm to Humidity, %rh 0 to 100 Thermocouple, C -50 to 950 Concentration calibration 3 points ph calibration 3 points Automatic temp. compensation yes Battery operating period, hrs MX300 Base unit supplied without sensor modules which POA must be ordered separately MX300 Base unit and large field case (empty). Case can take POA up to five sensors. Supplied without sensor modules which must be ordered separately Mono-mate kit. Comprises MX300 base unit, InLab 482 ph POA sensor module, standard field case and buffer sachets Trio-mate kit. Comprises MX300 base unit, InLab 781 POA conductivity, InLab 482 ph and InLab 681 dissolved oxygen sensor modules, large field case and buffer sachets InLab 781 Conductivity sensor module, 4 ring cell with POA integral temperature probe InLab 481 ph sensor module, plastic shaft POA InLab 482 ph sensor module plastic shaft with POA integral temperature probe InLab 489 ISFET ph sensor module with integral POA temperature probe InLab 681 Dissolved oxygen sensor module with POA integral temperature probe InLab 982 Duo module. Two parameter sensor module POA ph/conductivity with integral temperature probe InLab 983 Trio module. Three parameter sensor module POA ph/conductivity/dissolved oxygen integral temperature probe InLab 986 Humidity sensor module POA RS232 Interface module POA m Extension cable POA m Extension cable POA Other sensor modules are available, please enquire on for details shown with
2 Hanna, HI and HI Waterproof Conductivity/ TDS/ C Meters Pocket testers with simultaneous display of EC/TDS and temperature on an LCD screen. Automatic calibration and buffer recognition combine with adjustable automatic temperature compensation for a fast and accurate performance. Ergonomically designed, the waterproof case floats if dropped in water and also has a user replaceable twist & lock probe. Other features include; auto-off switch, stability indicator, low battery indicator, and adjustable EC/TDS conversion factor. Two versions available, depending on the conductivity/tds range. Model HI HI Range 0 to 3999µS/cm 0.01 to 19.99mS/cm 0 to 1999ppm 0.00 to 10.00ppt 0 to 60 C or 32 to 140 F 0 to 60 C or 32 to 140 F Resolution 1µS/cm 0.01mS/cm 1ppm 0.01ppt 0.1 C 0.1 C ±2% Full scale, ±0.5 C ±2% Full scale, ±0.5 C Auto at single point 1413µS, Auto at single point 12880µS/cm, 1382ppm or 1500ppm 6.44ppt or 9.02ppt Temp. comp. Auto with ß variable from 0.0% to 2.4% (both models) Battery 4x1.4V, approx 100 hours life with Hanna BEPS system (both models) Dimensions, mm 163x40x26 (both models) Weight, g 85 (both models) Cat No. Description Price HI conductivity/tds/ C meter POA HI conductivity/tds/ C meter POA Batteries, 1.4V, pack of 12 POA Hanna, HI-8633 and HI-8733 Multi-range Conductivity Meters Two meters ideal for production and quality control which use a 4-ring multi-range PVC probe to measure from deionized water to brine. for the entire range of readings is assured with single point calibration. Where the temperature fluctuates, use the HI-8733 with ATC together with an adjustable coefficient (b) from 0 to 2.5% per C, to ensure accuracy. Two year warranty on both models. Model HI-8633 HI-8733 Ranges 0.0 to 199.9µS/cm 0.0 to 199.9µS/cm 0 to 1999µS/cm 0 to 1999µS/cm 0.00 to 19.99mS/cm 0.00 to 19.99mS/cm 0.0 to 199.9mS/cm 0.0 to 199.9mS/cm Resolutions 0.1µS/cm 0.1µS/cm 1µS/cm 1µS/cm 0.01mS/cm 0.01mS/cm 0.1mS/cm 0.1mS/cm ±1% Full Scale ±1% Full Scale Manual Manual Temp. comp. Manual from 10 to 40 C, Automatic with an adjustable β with β of 2% per C from 0 to 2.5% per C Probe Included with 1 m cable Included with ATC and 1 m cable Battery type/life 1 x 9 V/100 hours approx.continuous use (both models) Dimensions, mm 185x82x45 (both models) Weight, g 55 (both models) HI-8633 conductivity meter with probe and battery POA HI-8733 conductivity meter with probe and battery POA Spare probe for model HI-8633 POA Spare probe for model HI-8733 POA Standard solution, 500 ml of 12880µS/cm for recalibration POA 272
3 Jenway, Model 470, Conductivity/TDS Meter A general purpose, hand held unit with ergonomic design. The liquid crystal display simultaneously shows temperature compensated conductivity or TDS and temperature. The casework is environmentally protected to IP65 making it ideal for the field or any portable situation. It is supplied with epoxy cell (K=1), batteries and instructions. The new results memory function allows 32 readings to be stored in non-volatile memory (results are retained even with no batteries fitted). These results are easily recalled and displayed on the LCD. Backlit LCD Environmentally protected case to IP65 Results memory function 500 hours of battery life* Direct calibration on standard solutions or by direct cell constant entry Simultaneous temperature reading Start up self test (validity check of both system and operator entered values) Carrying case included SP New * 25 C with alkaline cells Conductivity Ranges/resolution µs/0.01 µs µs/0.1 µs µs/1 µs mS/0.01mS mS/0.1mS mS/1mS* ±0.5% ± 2 digits TDS Range/resolution mg/l/0.01mg/l mg/l/0.1mgl mg/l/1mg/l g/l/0.01g/l g/l/0.1g/ g/l/1g/l* ±0.5% ± 2 digits Temperature Range/resolution -10 to 105 C/0.1 C or 14 to 221 F/1 F ±0.5 C/± 1 F ATC range 0 to 100 C/32 to 212 F Manual temp. comp. range 0 to 100 C/32 to 212 F Cell constant Digitally settable 0.01 to Reference temperature 18, 20 or 25 C settable Temperature coefficient 0.00 to 4.00%/ C linear EC ratio (TDS) 0.50 to 0.80 Auto standard recognition 10µS, 84µS, 1413µS or 12.88mS (manual override) Power 2 AA cells Dimensions (lxwxd), mm 175x75x35 Weight, g 250 * only with cell constant > SP Model 470 Conductivity/TDS meter supplied with epoxy cell (K=1), POA batteries and instructions. Supplied with carry case 273
4 Jenway, Models 4150 and 4200 Waterproof Conductivity Meters Completely waterproof and portable with robust, non-glass sensor. The 4150 and 4200 models are both supplied with epoxy conductivity cell (K=1), batteries and instruction manual. An in-built sensor gives a direct read-out of temperature. Model 4150 Conductivity/TDS/ C Meter This standard sensor has a nominal cell constant of The meter also enables the digital selection of cell constant values between and to facilitate the use of the wide range of cell options offered. Data logging up to 100 results Auto standard recognition Menu driven operation User selectable coefficient Model 4200 Conductivity/Resistivity/Salinity/TDS/ C Meter The measuring range of the model 4200 conductivity meter of 0 to 199.9mS is covered by five automatically switched ranges using a single cell. The in built software is able to calculate and report results as total dissolved solids (T.D.S.) in mg/l, salinity in g/l or resistivity in MΩ. The model 4200 offers the facility to download data held in memory to a printer or computer. 1-3 point calibration Auto standard recognition Fully GLP compliant RS232 interface using optional cradle Multi-lingual Mode Conductivity TDS Resistivity Temperature Salinity (4200 only) (4200 only) Ranges/resolution mS/ 0 200g/L/ 0 20MΩ/ -10 to 105 C/ g/L/ 0.1mS 0.1g/L 0.01MΩ 0.1 C 0.1g/L mS/ 0 20g/L/ 14 to 220 F/ 0.01mS 0.01g/L 1 F mS/ mg/L/ 0.001mS 1mg/L µS/ 0 200mg/L/ 0.1µS 0.1mg/L µS/ 0 20mg/L/ 0.01µS 0.01mg/L ±0.5% ±0.5% ±0.5% ±0.5 C/ 0 35 ±1/ ±2 digits ±2 digits ±2 digits ±1 F ±3 Cell constant (digital) Settable (both models) Ref. temp. 18, 20, 25 C (both models) Temp. coefficient 0.00 to 4.00%/ C linear (both models) Probes 4 plate configuration for 4200/2 plate configuration for Model 4150 conductivity meter supplied with epoxy cell with ATC (K=1), POA batteries and instruction manual Model 4200 conductivity meter supplied with epoxy cell with ATC (K=1), POA batteries and instruction manual Carrying case POA M conductivity standard POA For model Conductivity cell K=1 POA column printer POA Paper roll for printer POA Printer ribbon POA Interface cradle POA Interface cable kit POA 274
5 Hanna, HI-9033 Waterproof, Conductivity Meter Rugged and robust, this waterproof hand-held conductivity meter has been designed for use in the field. Featuring single point calibration and automatic temperature compensation, the extensive measurement range is obtainable from a single probe on a 1m cable. Supplied with conductivity probe, batteries and tough carry case Four selectable ranges Automatic temperature compensation Two year warranty Four ranges µS/cm, µS/cm, mS/cm and mS/cm Resolution 0.1µS/cm, 1µS/cm, 0.01mS/cm and 0.1mS/cm ±1% full scale Single point Temperature compensation Automatic from 10 C to 50 C Probe With ATC probe Operating temp., ºC 0 to 50 Dimensions, mm 196x80x60 Weight, g HI-9033 conductivity meter with probe, battery and case POA ,880µS/cm calibration solution, 460ml POA ,413µS/cm calibration solution, 460ml POA µS/cm calibration solution, 460ml POA ,000µS/cm calibration solution, 460ml POA Hanna, HI-9835 Waterproof Multi-range Conductivity/ TDS/ Salinity/ C Meter An extended range waterproof conductivity meter, which also reads TDS, NaCl and temperature. yet suitable for use in the laboratory, all measurements are taken with just one probe with readings displayed on a large dual level LCD screen. With improved resolution and accuracy, the meter can read from de-ionised water to sea water, automatically switching ranges. Main features include automatic calibration with seven pre-programmed buffers, automatic temperature compensation with optional manual or nil compensation for actual conductivity readings, adjustable temperature coefficient and stability indicator. Can be run from mains supply with optional power pack. Supplied complete with probe on 1m of cable, batteries and attaché case Mode Conductivity TDS Salinity Temperature Ranges/Resolution µS/cm / 0.01µS/cm ppm / 0.01ppm %/ C/ µS/cm / 0.1µS/cm ppm / 0.1ppm µS/cm / 1µS/cm ppm / 1ppm mS/cm / 0.01mS/cm g/L / 0.01g/L mS/cm / 0.1mS/cm g/L / 0.1g/L up to 500.0mS/cm actual EC up to ppt ±1% of reading (0.05µS/cm ±1% of reading (0.03 ppm ±1% of reading ±0.4 C or 1 digit whichever greater) or 1 digit whichever greater) 1 point procedure with 6 memorised buffers at; 0.0, 84.0, 1413µS/cm, 12.88, 80.0, 111.8mS/cm. NaCl at 100%. Temperature compensation Auto or manual from 0 to 60.0 C (can be disabled to measure actual conductivity). /TDS factor With adjustable coefficient from 0.00 to 6.00%/C. TDS factor adjustable from 0.40 to 0.80 Battery type/life 4x 1.5V AA/150 hours approx. continuous use, or 12vdc mains supply. Auto-off after 5 minutes (can be disabled) Dimensions, mm/ Weight, g 196x80x60/ HI-9835 waterproof conductivity/tds meter with probe, batteries and carry case. POA HI-12VDC Mains power adaptor POA ,880µS/cm calibration solution, 460ml POA µS/cm calibration solution, 460ml POA ,413µS/cm calibration solution, 460ml POA 275
6 Hanna, HI and HI Waterproof Conductivity/ TDS/ ph/ C Combination Meters New waterproof hand held combined meters measuring conductivity, ph and temperature all with one probe. Simply press a button to go from one parameter to the next. for ph is at two points from 5 memorised buffers. One point conductivity calibration is automatic with user selectable conversion factor. Also features a stability indicator and battery power check. Supplied with combination probe/electrode and attaché case. ph Conductivity TDS Temperature, C Ranges HI to µS/cm ppm 0-60 HI to mS/cm ppt 0-60 Resolution HI µS/cm 1ppm 0.1 HI mS/cm 0.01ppt 0.1 HI ±0.01 2% full scale 2% full scale ±0.5 HI ±0.01 2% full scale 2% full scale ±0.5 Dimensions (wxdxl), mm 143x80x38 (both models) Weight, g 320 (both models) HI conductivity meter/tds/ph/ C meter with probe and attaché case POA HI conductivity meter/tds/ph/ C meter with probe and attaché case POA Replacement probe POA Protective rubber boot POA µS/cm, 460ml calibration solution for HI POA µS/cm, 460ml calibration solution for HI POA ph 4.01 ph buffer solution, 460ml POA ph 7.01 ph buffer solution, 460ml POA Hanna, HI , Compact Conductivity Meter The HI is a robust, portable conductivity meter with a useful wrist strap and an optional outer protective rubber holster for field use. It uses the Hanna 4-ring technology which allows the meter to sample from de-ionised water through to brine without the need to change probes. Simply switch the meter on, dip into the sample and choose the measurement range. All readings are automatically compensated for temperature variations by 2% per ºC. is manual at a single point, choosing the buffer solution most suitable for your application. The probe is durable and has a removable plastic cover for easy cleaning. Range 0.0 to 199.9µS/cm, 0 to 1999µS/cm, 0.00 to 19.99mS/cm, 0.0 to 199.9mS/cm Resolution 0.1µS/cm, 1µS/cm, 0.01mS/cm, 0.1mS/cm, % ±1% full scale Single point via trimmer Temperature compensation Automatic from 10 to 40ºC with ß of 2% Probe 1m cable, 4-ring probe, for use across entire range Battery type/life 1x9V/100 hours use Environment 0 to 50ºC, RH 95% Dimensions, mm 143x80x38 Weight, g HI compact conductivity meter with HI-76302W conductivity POA probe, cable, screwdriver, wrist-strap, 9V battery and manual µS/cm, 460ml calibration solution POA µS/cm, 460ml calibration solution POA µS/cm, 460ml calibration solution POA µS/cm, 460ml calibration solution POA Protective rubber holster POA 276
7 Bench Jenway, Models 4510 and 4520 Conductivity/TDS Meters Model 4510 A general purpose conductivity/tds/temperature bench meter for use in laboratory situations. The instrument includes a 32 reading memory facility. Ideal for routine laboratory applications Automatic temperature compensation Conductivity/TDS display 32 reading memory Automatic range selection RS232 serial interface on standard solutions or direct Analogue recorder output cell constant entry Wall mounting option Model 4520 A laboratory unit with more sophisticated features. Automatic range selection status and reminder Conductivity/TDS display 500 reading memory on up to 3 standard solutions or Comprehensive data logging options direct cell constant entry RS232 serial and IrDA printer interface ATC, including pure water temperature Alarm outputs compensation Analogue recorder output Security code protected user data Wall mounting option Model Conductivity Ranges 0 to 19.99µS/0 to 199.9µS/0 to 1999µS/ 0 to 19.99µS/0 to 199.9µS/0 to 1999µS/0 to 19.99mS/ 0 to 19.99mS/0to 199.9mS/0 to 1999mS* 0 to 199.9mS/0 to 1999mS/0 to 19.99S* *1999mS using X10 cell *19.99S using X10 cell Resolution 0.01µS/0.1µS/1µS/0.01mS/0.1mS/1mS* 0.01µS/0.1µS/1µS/0.01mS/0.1mS/1mS/0.01S* ±0.5% ±2 digits ±0.5% ±2 digits TDS Ranges 0 to 19.99mg/l /0 to 199.9mg/l/0 to 1999mg/l/ 0 to 19.99mg/l /0 to 199.9mg/l/0 to 1999mg/l/ 0 to 19.99g/l/0 to 199.9g/l/0 to 1999g/l* 0 to 19.99g/l/0 to 199.9g/l/0 to 1999g/l* *using X10 cell *using X10 cell Resolution 0.01mg/l to 1g/l 0.01mg/l to 1g/l ±0.5% ±2 digits ±0.5% ±2 digits Resistivity Range/Resolution 0 to 20MΩ/0.01MΩ Salinity Range/Resolution/ 0 to 99.9g/l/0.1g/l/0 to 35 ±1g/l/35 to 99.9±3g/l Temperature Range -10 to 105 C (14 to 221 F) -10 to 105 C (14 to 221 F) Resolution 0.1 C (1 F) 0.1 C (1 F) ±0.5 C (±1 F) ±0.5 C (±1 F) ATC range 0 to 100 C (32 to 212 F) 0 to 100 C (32 to 212 F) Manual TC range 0 to 100 C (32 to 212 F) 0 to 100 C (32 to 212 F) Cell constant to to Temp. coeff. 0.00% to 4.00% 0.00% to 4.00% Ref. temp. 18, 20 or 25 C 18, 20 or 25 C EC ratio 0.50 to to , 2 or 3 point 1, 2 or 3 point Auto std recog. 10µS, 84µS, 1413µS, 12.88mS 10µS, 84µS, 1413µS, 12.88mS Outputs Analogue/RS232 Analogue, RS232 serial & IrDA interface Clock 24 hours, hrs/min/sec or day of month/month/year, leap year corrected. GLP reminder interval (1 to 999 hours) Alarm outputs (open collector and audible). Security code protected user data Display 3 digit LCD Back lit 1/8 VGA monochrome LCD Languages English English, French, German, Italian, Portuguese and Spanish Power 9V power supply 9V power supply Dimensions, mm/weight, g 210x250x55/ x250x55/ Conductivity/TDS meter supplied with glass bodied conductivity cell with ATC K=1, electrode holder, power supply, condensed POA operating instructions and instruction manual Conductivity/TDS meter supplied with glass bodied conductivity cell with ATC K=1, electrode holder, power supply, condensed POA operating instructions and instruction manual. For accessories see page New New
8 Bench Jenway, Model 3540 Conductivity and ph Meter The Model 3540 is ideal for use in water testing applications and in all laboratories where ph and conductivity analysis is required. The bright back lit LCD has five separate tabbed screens, each accessed with the simple navigation keys. The set-up menu gives quick and easy access to the wide range of instrument, ph and conductivity measurement options. of both the ph and conductivity channels is automatic, with the option to select 1, 2 or 3 calibration points for each. Automatically recognised ph buffers conforming to the NIST, DIN and JIS standards can be overridden by manually entered values, as can the 4 automatically recognised conductivity standards. An option to calibrate the conductivity channel to a cell constant is also included. The conductivity channel has a special ultra-pure water function which enables the ideal temperature compensation algorithm for this exacting application. Other modes of operation enable resistivity, salinity and TDS measurement. The ph channel can also display mv values to 0.1mV resolution, enabling ORP/Redox measurements to be made. The in-built data logger can store up to 250 ph and conductivity readings based on manual or automatically timed triggers, as well as from stability and alarm status. Logged results can either be sent to the internal memory or via the RS232 serial port to the optional printer. The comprehensive GLP functions include calibration reminders and status tracking, operator and sample ID management and a supervisor security code for all set-up options. Simultaneous display of ph and conductivity Two independent channels (e.g; ph and/or conductivity) Menu driven operation Datalogging with variable triggers Resistivity, TDS and Salinity modes Comprehensive GLP support Conductivity Range Auto ranging from 0.01µS to 1.999S (19.99S using X10 cell) Resolution 0.01µS to 1mS (0.01S using X10 cell) ±0.5% ±2 digits 1, 2 or 3 points Auto std recog. 10µS, 84µS, 1413µS, 12.88mS Manual std recog. Any value entered within the range or by cell constant value Reference temperature 18, 20, 25 C Temperature coefficient 0 (off) to 4%/ C ph Ranges to Resolution/ 0.001, 0.01, 0.1 selectable/±0.003 mv (Absolute or Relative) Range to Resolution 0.1 ±0.2 Input Impedance >10 12 ohms 1, 2 or 3 points Auto buffer recog. Jenway, NIST, DIN, JIS Manual buffer recog. Any value entered within the range Temperature (for each channel) Range -10 to 105 C (14 to 221 F) Resolution/ 0.1 C (1 F)/±0.5 C (±1 F) ATC range 0 to 100 C (32 to 212 F) Manual TC range 0 to 100 C (32 to 212 F) Outputs Analogue, RS232 serial and alarms Memory 250 reading (ph with conductivity) Clock 24 hours, hrs/min/sec or day of month/month/year, leap year corrected. GLP reminder interval (1 to 999 hours) Alarm outputs (open collector and audible) Security code protected - user and batch ID Display Back lit 1/8 VGA monochrome LCD Power 9V power supply (230V-110V mains adaptor) Dimensions, mm 210x250x55 Weight, g conductivity/ph meter supplied with glass bodied combination POA ph electrode, glass conductivity cell with ATC K=1, electrode holder, ATC probe, BNC shorting plug, 4, 7 and 10 ph buffer sachets, power supply, condensed operating instructions and instruction manual. 278
9 Bench Mettler Toledo, S30K and S70K Conductivity Meters S30K SevenEasy conductivity meter kit This new conductivity meter has four measurement modes: conductivity, resistivity, TDS and salinity. A cost effective solution for the workplace with built-in flexibility enabling it to be used as a portable or bench conductivity meter. Easy access keys and clear LCD displays the conductivity, temperature and standards used. Features include editable cell constant, automatic temperature compensation that can be switched on or off and self diagnostics for ease of use. RS232 interface for connection to PC or printer. Electrode arm that can be attached to the Selectable reference temperature 20 or 25 C meter or stand-alone Manual and auto read Auto buffer recognition Reading stable/ready indicator Linear and non-linear correction Editable cell constant S70K SevenMulti conductivity meter kit The S70 provides reliable conductivity measurement from routine analyses through to the most demanding applications. A new user-friendly instrument featuring an on-line user help screen for quick reference and hot keys for easy operation. Optional expansion units make it possible to measure ph, conductivity, ISE and ISFET using one meter. Comprehensive GLP support with features including: password protection; graphical display of calibration curve; last 10 calibrations with date and time and calibration reminder. In addition to the features listed for S30K model the S70K also features: Display of last 25 readings Memory for 10 methods and 1000 measured values Alphanumeric input of meter ID, user name, sample ID, serial no. User defined high/low limits Timed interval reading, output of readings to printer/memory at defined intervals USP mode, compliance with latest standards for ultra pure water, USP <645> stages 2 and New New Model S30K S70K Conductivity measurement Range 0.1µs/cm 500mS/cm (auto-ranging) 0.01µs/cm 1000mS/cm (auto-ranging) Resolution/ 2 decimal places/±0.5% 2 decimal places/±0.5% Total Dissolved Solids measurement Range 0.1mg/l 2000g/l 0.1mg/l 2000g/l Resolution/ 2 decimal places/±0.5% Adjustable solids factor 2 decimal places/±0.5% Adjustable solids factor Temperature measurement, C Range/Resolution/ -5.0 to 105/0.1/± to 130/0.1/±0.1 Salinity ppt (parts per thousand) ppt (parts per thousand) Resistivity Mega Ω cm Mega Ωcm points 1 of 3 (84µS/cm, 1413µS/cm, 12.88mS/cm) 1 of 4 (84µS/cm, 1413µS/cm, 12.88mS/cm, sat NaCl) & user defined Cell constant Editable Input, edit and recall Inputs Mini-DIN, power, RS232 Mini-DIN, titrator output, power, RS232, analogue output Power Mains (9V DC) or 4 x AA batteries Mains (9V DC) Dimensions (wxdxh), mm 180x180x65 190x240x65 Weight, g (+135g for one expansion unit - supplied)* * Plus 135g for each expansion unit S30K SevenEasy conductivity meter with Inlab 730 conductivity electrode, electrode arm, conductivity standards (2x 1413µS/cm POA and 2x 12.88mS/cm), guide to conductivity measurement booklet, protective cover and meter test certificate S70K SevenMulti benchtop conductivity meter. Supplied as above POA For S70K SevenMulti conductivity meter ph expansion unit POA ISFET expansion unit POA ISE expansion unit POA Replacement protective cover POA For S30K and S70K conductivity meters InLab 710 conductivity probe (4 plate glass for mS/cm) POA Electrode arm assembly POA InLab 720 conductivity probe (2 plate glass for µS/cm) POA RS-P42 Printer (requires RS232 cable) POA InLab 730 conductivity probe ( mS/cm) POA RS232 cable for PC/RS-P42 printer POA Flow cell for use with Inlab 740 and Inlab 720 (reduces CO2 absorption) POA Balance link software (requires RS232) POA InLab 740 conductivity electrode pure water applications POA (SevenEasy only) USP (steel, µS/cm)* Temperature probe (NTC30K) POA * For USP, ultra pure water applications order Inlab 740 conductivity electrode, supplied with a certificate that states the cell constant of each individual probe.
10 Bench New Hanna, HI-2300 Extended Range Bench Conductivity/TDS/Salinity/ C Meter An extended range microprocessor conductivity meter, which also reads TDS, NaCl and temperature. All measurements are taken with just one probe with readings displayed on a large LCD screen. With improved resolution and accuracy the meter can read from de-ionised water to seawater, automatically switching ranges to the scale with the best resolution. Other features include: Automatic calibration with six pre-programmed buffers Automatic temperature compensation with optional manual or nil compensation for actual conductivity readings Adjustable temperature coefficient Adjustable EC and TDS factor GLP features RS232 interface Two year meter guarantee Supplied complete with probe on 1m of cable, probe stand and power adaptor. Model Range Resolution Conductivity 00.0 to 29.99/30.0 to 299.9/300 to 2999 µs/cm 0.01/0.1 ms/cm 3.00 to 29.99/30.0 to ms/cm 0.01/0.1/1 µs/cm Actual conductivity Up to ms/cm actual conductivity* TDS 0.00 to 14.99/15.0 to /150 to 1499 mg/l (ppm) 0.01/0.1/1 ppm 1.50 to 14.99/15.0 to g/l (ppt) 0.01/0.1 g/l Actual TDS Up to g/l (ppt) actual TDS* (with 0.80 factor) NaCl 0.0 to % 0.1 % Temperature 0.0 to 60.0 C 0.1 C EC ±1% of reading ±(0.05 µs/cm or 1 digit, whichever greater) TDS 1% of reading ±(0.03 ppm or 1 digit, whichever greater) NaCl ±1% of reading Temperature ±0.4 C EC 1 point with 6 memorized buffers: 84, 1413, 5000, 12880, or µs/cm NaCl 1 point with optional buffer ( ) Temperature 2 points at 0 and 50 C (plus ±1 C adjustment) Temp. compensation Automatic or Manual from 0 to 60 C (can be disabled to measure actual conductivity) Temp. coefficient 0.00 to 6.00 %/ C (for EC and TDS only) Default value is 1.90%/ C TDS factor 0.40 to 0.80 (default value is 0.50) Probe HI Platinum 4-ring probe, K=1 nominal and built-in temperature sensor (included) GLP Storing of last calibration data Serial interface RS232 - downloading of last calibration data Power supply 12 VDC adaptor (included) Auto off After 5 minutes (can be disabled) Environment 32 to 122 F (0 to 50 C); 95% RH non-condensing Dimensions (lxwxd), mm 230x170x70 Weight, kg 1.2 * Actual conductivity (or TDS) is the non-temperature compensated conductivity (or TDS) value of a solution HI-2300 Extended range bench conductivity/tds/salinity/ C meter with probe, POA probe stand and mains power adaptor µS/cm, 460ml calibration solution POA µS/cm, 460ml calibration solution POA µS/cm, 460ml calibration solution POA % NaCl sea water solution, 230ml POA Windows software POA RS232 connection cable POA 280
11 Bench Hanna, EC-214 and EC-215 Bench Conductivity Meters Two easy to use bench conductivity meters with temperature compensation. The EC-214 compensates manually and the EC-215 automatically and both can be calibrated with a wide range of calibration solutions. Both meters cover four measurement ranges reading from de-ionised water to brine using just one probe. Supplied with EC probe and mains power transformer. Model EC-214 EC-215 Ranges 0.0 to 199.9µS/cm, 0 to 1999µS/cm, 0.00 to 19.99mS/cm, 0.0 to 199.9mS/cm (both models) Resolution 0.1µS/cm, 1µS/cm, 0.01mS/cm, 0.1mS/cm (both models) ±1% full scale (both models) Manual 1 point (both models) Temperature compensation Manual from 0 to 50 C Automatic from 0 to 50 C Dimensions (lxwxd), mm 240x182x74 (both models) Weight, kg 1.0 (both models) EC-214 Bench conductivity meter with probe and mains power transformer POA EC-215 Bench conductivity meter with probe and mains power transformer POA for EC-214 and EC Electrode holder POA µS/cm, 460ml calibration solution POA µS/cm, 460ml calibration solution POA µS/cm, 460ml calibration solution POA Laboratory Conductivity Cells Supplied with 1 metre of cable. Models K20, K21, K22 and K25 are glass free. Type K25 is 4 ring. The temperature range of all cells is 0ºC to 50ºC. When ordering conductivity cells please specify make and model of conductivity meter. These cells do not have an internal ATC, although this is available as an option. Please specify when ordering Cat. No. Model Range Body Plate Dims. Cell Application Price Type Material mm Constant K10 0 to 150mS Glass Pt 120x12 K=1 General POA K20 0 to 10mS Epoxy Carbon 100x12 K=1 Paints, inks, POA dyes, foodstuffs K21 0 to 500µS Epoxy Carbon 120x12 K=0.1 Pure water POA K22 0 to 0.5S Epoxy Carbon 120x12 K=10 Solutions with POA high conduct K25 0 to 1S Epoxy Carbon 120x12 K=0.55 Aqueous/ POA non aqueous K30 0 to 150mS Glass Pt 120x12 K=1 Flow through POA K40 0 to 500µS Glass Pt 120x12 K=0.1 Pure water POA Note: When ordering conductivity cells please specify make and model of conductivity meter. 281
Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen
Laboratory Electrochemistry Products ph Conductivity Dissolved Oxygen Spoilt for choice Small footprint Adjustable viewing angle Wall mountable New style electrode holder Contents page Overview................................3
More informationELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:
BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data
More informationResolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or
More informationOperating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso
Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso SevenEasy Conductivity Italiano Español Français Deutsch English Contents Contents Page 1. Introduction...
More informationDPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters
ELMETRON meters Robust and reliable pocket tester or computerized laboratory equipment Excellent friendly priced quality for research, education and process control 2 DPST-ELMETRON-meters You need a robust,
More information4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
More informationConductivity and TDS Meters
Table of Contents Comparison Charts Introduction Portable Meters Waterproof Meters Printing & Logging Portable Meters Bench Meters Combination EC/TDS/pH Meter Page G2 G3 G6 G11 G14 G15 G16 G1 Comparison
More informationUser Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationEutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature
Eutech 2700 Series Bench Meters ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature Features Comprehensive Backlit Display All Measurements Include Temperature Display Up To 500
More informationUser's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
More informationOPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
More informationMODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL
MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL 430 350/REV A/10-03 MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL CONTENTS Introduction 1 Specification 2 Installation 3 Displays 3-4
More informationUser Guide. Temperature and Humidity Datalogger. Model 42280
User Guide Temperature and Humidity Datalogger Model 42280 Introduction Congratulations on your purchase of the Extech 42280 Thermometer and Relative Humidity Datalogger. The 42280 is a wall-mount, tripod
More informationCompact ph Measuring Instruments
testo 205, 206, 230 Compact ph Measuring Instruments With innovative probe engineering ph C The new ph measuring instruments with innovative probe engineering Measurement of the ph value plays an important
More informationHow To Use An Irius Pid Detector
SIRIUS PID & 4-Gas Detector [ Compact and Versatile for all your needs] SIRIUS [ Maximum versatility in one hand] The new SIRIUS PID Detector combines incredible performance, versatility and ease of use
More informationUser Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending
User Guide ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens Patent Pending Getting Started Remove the cap from the bottom of the ExStik TM to expose the electrode bulb and reference
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationOXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system
Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can
More informationGalvanic Parts Per Million Dissolved Oxygen Systems
Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in
More informationModel 4510 Conductivity/TDS Meter Operating Manual
Model 4510 Conductivity/TDS Meter Operating Manual SAFETY Please read this information carefully prior to installing or using this equipment. 1. The unit described in this manual is designed to be operated
More informationConductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.
Meters Meters is a parameter used to measure the ionic concentration and activity of a solution. The more salt, acid or alkali in a solution, the greater its conductivity. The unit of conductivity is S/m,
More informationMilwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationUSB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
More informationMelting Point Apparatus
Melting Point Apparatus Mel-Temp and IA9000 Series Electrothermal s range of melting point apparatus consists of the Mel-Temp and IA9100, IA9200, IA9300. The MelTemp gives a temperature resolution of ±1ºC,
More informationMilwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationWahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
More informationIncubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
More informationTemperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
More informationUser Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
More informationWireless Data Logger Monitoring Systems
Wireless Data Logger Monitoring Systems Table of Contents About MadgeTech, Inc. Wireless Systems & Components Wireless Data Loggers 2000A Wireless Data Logger Models MadgeTech Cloud Services MadgeTech
More information450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer
450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon
More informationrigel 288 Electrical Medical Safety Analyser Key Features Applications
rigel 288 Electrical Medical Safety Analyser Key Features Versatile Test in Accordance with the leakage requirements of IEC/EN 60601-1, AAMI and NFPA, IEC 62353 (VDE 0751-1) using separate IEC 60601 and
More informationInstruction Manual HI 9146. Portable Waterproof Microprocessor Dissolved Oxygen Meter
Instruction Manual HI 9146 Portable Waterproof Microprocessor Dissolved Oxygen Meter w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction
More informationMelting Point Range. with BioCote antimicrobial protection
Melting Point Range with BioCote antimicrobial protection Stuart has become the laboratory name in melting points. Offering solutions to determine high accuracy melting points from manual to automatic
More informationHighly efficient flue gas analyzer
Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement
More informationUser Manual. Thermo Scientific Orion VERSA STAR
User Manual Thermo Scientific Orion VERSA STAR Advanced Electrochemistry Benchtop Meter 68X006501 Revision A April 2014 Contents Chapter 1 Meter Introduction... 6 Meter Overview... 6 Packing List... 7
More informationElectronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
More informationUSB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationDual Laser InfraRed (IR) Thermometer
User Manual Dual Laser InfraRed (IR) Thermometer MODEL 42570 Introduction Congratulations on your purchase of the Model 42570 IR Thermometer. This Infrared thermometer measures and displays non-contact
More informationDISSOLVED OXYGEN METER Model : DO-5509
DISSOLVED OXYGEN METER Model : DO-5509 Your purchase of this DISSOLVED OXYGEN METER marks a step forward for you into the field of precision measurement. Although this DISSOLVED OXYGEN METER is a complex
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationUSB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
More informationUser's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600
User's Guide ExStik DO600 Dissolved Oxygen Meter II RECALL Dissolved Oxygen DO600 Introduction Congratulations on your purchase of the ExStik DO600 dissolved oxygen / temperature meter which simultaneously
More informationFLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
More informationPAT Tester Printers and Barcode Scanners
PAT Tester Printers and Barcode Scanners Test n Tag Elite An extremely rugged battery powered mobile printer which prints durable synthetic asset labels. Long battery life and high impact resistance make
More informationSevenGo Duo. Quick and Reliable Measurements for Results at your Fingertips. SevenGo Duo Portables SevenGo Duo SevenGo Duo pro
SevenGo Duo SevenGo Duo Portables SevenGo Duo SevenGo Duo pro ph / ORP Conductivity Ion Concentration Dissolved Oxygen Quick and Reliable Measurements for Results at your Fingertips Introduction The SevenGo
More informationUltrasonic Load Monitoring
Ultrasonic Load Monitoring Who We Are One Company, Total Support, Complete Solutions Over many years, Hydratight has provided world-class bolted joint solutions and continues to set international standards
More informationph 200 ph-/redox-/temperature Meter Operating instructions
ph 200 ph-/redox-/temperature Meter Operating instructions 2 Table of Contents Page 1. Scope of delivery...4 2. System description...4 3. Connections...5 4. Display...7 5. Keypad...7 6. Start up...8 7.
More informationData Logging Solutions from Lascar Electronics
Data Logging Solutions from Lascar Electronics Remote Monitoring EL-BT-2 Bluetooth and Humidity Data Logging The EL-BT-2 data logger measures and stores over 1 million temperature and humidity readings.
More informationYSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen
YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen 1. Check the log-book to see if somebody else has already checked the meter for accuracy within the timeframes below. If the meter hasn
More informationACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget
ACE Automated Soil CO 2 Exchange System Automated operation Automatically exposes soil area between measurements CO 2 analyser in chamber Highly accurate CO 2 IRGA housed directly inside soil chamber assembly
More informationEquipment for Analysis
Colourimeters Conductivity Meters Dissolved Oxygen Meters Fluorimeters Flame Photometers Ion Meters ph Meters UV/Visible Spectrophotometers Life Science Spectrophotometers Double Beam Spectrophotometers
More informationShort Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
More informationTurbiDirect TurbiCheck TurbiCheck WL
Turbidity 128 TurbiDirect TurbiCheck TurbiCheck WL www.lovibond.com General Catalogue February 2013 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid
More informationCurrent Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
More informationWhen your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.
Voyager Pro Analytical and Precision Balances When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task. Voyager Pro s Advanced Applications simplify even the
More informationRS DIGITAL THERMOMETER
RS DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL C F MX MN AVG TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION... 1 2. SPECIFICATIONS... 1 3. NAME OF PARTS AND POSITIONS... 3 4. OPERATION INSTRUCTIONS... 5
More informationGround Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
More informationMIT510/2, MIT520/2 and MIT1020/2
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com MIT510/2, MIT520/2 and MIT1020/2 Line supply or battery operated Digital/analog
More informationPortaSens ll G AS DETECTOR
PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor
More informationDistributed by TestEquity LLC 800-950-3457 http://www.testequity.com
Meters Meters Extech sound meters include all the features/functions needed for basic noise level surveys or to meet the requirements for OSHA compliance, community noise ordinances or machine noise evaluation.
More informationUltraBasic Benchtop ph Meter Operation Manual
UltraBasic Benchtop Meter Operation Manual UB-5 Denver Instrument Measuring 4 4 7 10 Meter 22.2 C 4.06 UltraBasic 902388.1 Rev. A UltraBasic Meter Quick Reference 1. Connect a AC adapter to the power connection.
More informationOperating Instructions
Operating Instructions FiveEasyPlus ph meter FEP20 Contents Contents 1. Introduction 3 2. Safety measures 3 3. Installation 4 3.1 Installing the electrode arm (optional for FEP20) 4 4. Operating the FiveEasyPlus
More informationPhysical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
More informationNew thermometers and accessories to grow your business
New s and accessories to grow your business Fluke is introducing a new family of digital, contact s and accessories. Here is the information you will need to order, promote and sell these exciting, new
More information1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
More informationSWISS MADE. Series 320 XB MASTER. Analytical. Precision
SWISS MADE MASTER Series Analytical Precision MASTER Series The Precisa 320 high performance series combines precision and quality, and offers the highest metrological performance and advanced integrated
More informationTest equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
More informationHT580 User Reference Guide. Version 1.0
Version 1.0 NOTICE 1. Li-Ion Battery Pack The HT580 Portable Terminal and the Li-Ion Battery Pack are packaged separately. You will have to install the Battery Pack when you receive your terminal. Please
More informationFluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
More informationRepeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
More informationIon-selective Measurements
Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
More informationWAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F
Wireless Asset Monitoring - Local Food Safety Software BA/WAM-L-F Software Installation and User Guide System Overview The BAPI Wireless Asset Monitoring Local (WAM Local) Software receives temperature
More informationMultifunction HVAC and IAQ Meter
testo 435 Multifunction HVAC and IAQ Meter NEW! The newest technology for temperature, humidity, air flow and more! cfm P CO 2 %RH F Lux All the right parameters for HVAC and IAQ The testo 435 is perfect
More informationRS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationInterface Level And Point Level Analyzers & Sensors
Interface Level And Point Level Analyzers & Sensors Model 2511 Analyzer Model 2505 System Model 2120 System Royce now offers a complete line of Interface Level and Point Level Analyzers that make it possible
More informationOverview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
More informationMelting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
More informationCurrent Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
More informationCompact Water Quality Meter B-700 series
Compact Water Quality Meter B-700 series Actual Size Compact Water Quality Meter Debut! HORIBA s 60 years of sensor engineering realize accurate direct measurement from only a single drop on the unique
More informationOT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
More informationJUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor
Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g. drinking and surface water monitoring,
More informationMicrowave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
More informationLightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
More informationWeighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene
Weighing terminals The stainless steel weighing terminals of the 4 Series: IND429, IND439 and IND449 The optimal solution for demanding applications in the food, pharmaceutical and chemical industries.
More informationPremium Server Client Software
Premium Server Client Software Server / Client SMSPro & GSMS TH series Get the tools on hand Premium Server is designed to cover most of the applications in the market. It gives a hassle free management
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
More informationOperating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007
Operating manual ph/cond 3400i 5 3 0 Tref25 nlf 2 5 0 S/ C TP M AR STO CAL O AR ph/conductivity measuring instrument ba75687e01 01/2007 Accuracy when going to press The use of advanced technology and the
More informationHOBO U14 Data Logger User Manual
HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity
More informationTR Series Surface Roughness Tester for workshop and laboratory
TR Series Surface Roughness Tester for workshop and laboratory Portable, rugged and instant operation on metallic and ceramic surfaces Surface roughness measurement the basics Application Surface roughness
More informationDPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators
Features Ranges 2.5 mbar to 700 bar Accuracy from 0.025% full scale (FS) Integral combined pressure/vacuum pump Dual readout: input and output 4 to 20 ma loop test: auto step and ramp Intrinsically safe
More informationWide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer
User Manual Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer MODEL 42515 Introduction Congratulations on your purchase of the Model 42515 IR Thermometer. The Model 42515 IR thermometer
More informationSTERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
More informationIntegrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
More informationBlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
Manual EN BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000 Contents EN 1.Important safety instructions... 2 2. Installation... 2 3.Product
More information