Section A. This Section includes the following: 1. Stile and Rail Medium Density Fiberboard (M.D.F) doors, fire-rated and nonfire-rated.
|
|
- Wilfrid Barnett
- 7 years ago
- Views:
Transcription
1 Part 1 General Section Related Documents A. Drawings and general provisions 1.2 Summary A. This Section includes the following: 1. Stile and Rail Medium Density Fiberboard (M.D.F) doors, fire-rated and nonfire-rated. 2. Fire Rated Stile and Rail Doors (with intumescent cores) 3. Stile and Rail True and False Louver Doors B. Related Sections include the following: 1. Section LEED Requirements (if applicable) 2. Section General Requirements 3. Section Wood, Plastics and Composites 4. Section Specialty Doors and Frames 5. Section Door Hardware 6. Section Glazing 7. Section Finishes C. American Society for Testing and Materials (ASTM): 1. ASTM D Standard Methods for Evaluating the properties of Wood-Based Fiber and Particle Board Panel Materials. 2. ASTM E a Standard Methods of Fire Tests of Door Assemblies D. Quality Standards 1. NWWDMA (National Wood Window & Door Association) Industry Standard 2. AWI (Architectural Woodwork Institute) Standards, 7th Edition. 3 Medium Density Fiberboard Doors: Comply with ANSI A208.2, Standard for Medium Density Fiberboard (MDF) 4. UL10C. 5. NFPA ASTM E CARB (California Air Resources Board) Emission standards for Formaldehyde Standards E. Approved Labeling Agencies for Fire Rated Doors. 1. Underwriters Laboratories (UL)
2 2. Warnock Hersey/Intertek. 3. QAI Laboratories F. ALL MDF shall be double refined material and have a minimum 48 pound density. 1.3 SUBMITTALS A. Shop drawings: Indicate location, size, and hand of each door, identifying symbols, fire ratings, clearances, elevation of each kind of door; details of construction, and other necessary data. 1. Factory-Machined Doors: Templates required for lockset cut-outs, hinge cutouts, and any other hardware or prep necessary. Customer may be asked to supply actual hardware samples. B. Product Data: For each type of door. Include details of core and patented construction. Include factory-finishing specifications and the following: 1. Detailed specifications for construction and fabrication. 2. Specifications and Installation Instructions 3. Finishing Instructions for field-finished doors. 4. Recommendation for care and maintenance of doors. C. LEED Submit appropriate documentation to support LEED credits required. STANDARD MR4.1 and 4.2: Interior MDF doors to contain a minimum of 86% recycled content as certified by Scientific Certification Systems (SCS) or other independent certification body. OPTIONAL MR 7.0: Forest Stewardship Council FSC Material Independently verified through third party certification body and current certificate must be available and submitted with project documents. (FSC-C015231) EQ 4.4: No Added Urea Formaldehyde Material DELIVERY, PROJECT CONDITIONS, STORAGE, AND HANDLING A. Comply with requirements of referenced standard and manufacturers written instructions 1. Delivery: Do not deliver doors to building until it is entirely enclosed, drywall, HVAC, plaster and concrete work is completed and dry and humidity in the building has reached average relative humidity at occupancy levels.
3 1.6 WARRANTY 2. Handling: Do not drag doors across one another or 'walk' a door on its corners 3. Storage: Stack doors flat and off floor on a level surface in a dry, well ventilated area. Do not stand on end. Keep doors covered while allowing air circulation. 4. Protection: Do not subject doors to abnormal heat, dryness, humidity or drastic changes in these conditions. Allow sufficient time for doors to acclimate to average existing conditions of the area before installation. 5. Doors require light sanding before being painted. A. General Warranty: Supa Doors are warranted for interior use only. Contact manufacturer for full warranty coverage details and updates. PART 2 - PRODUCTS 1. Interior MDF Doors: Limited Lifetime. 2.1 MANUFACTURERS A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering Stile and Rail, continuously laminated, MDF doors may be incorporated into the Work. All doors must be sourced from one single manufacturer with at least 20 years experience constructing MDF doors. Routed doors are not acceptable. 1. SUPA Doors B. Substitutions: Substitutions allowed only upon review and approval by architect. 2.2 DOOR TYPES A. MDF (Medium Density Fiberboard) Doors: Available in 1-3/8 inches and 1-3/4 inches thick, stile and rail, continuously laminated construction, sizes as noted on Door Schedule with panel/sticking/molding design as specified by Interior Designer/Owner. Doors to have a hardwood keyed woodedge down the full length of each stile. Exposed woodedges that are not interlocking into door edge are not acceptable. B. Core Materials 1. Non-rated Core: Medium Density Fiberboard 2. Fire Rated Core (20 Minute):; Medium Density Fiberboard (see door schedule for locations). 3. Fire rated Stile and Rail using intumescent core with Warnock Hersey Label (45, 60, 90 Minutes) 4. All core materials should make door achieve STC 32 or greater to minimize sound transmission on this project (applicable to 1-3/4 doors or thicker).
4 C. Panels: Detail as shown on architectural plans. 1. Panels shall NOT be quoted or supplied with less than the following thicknesses. For 1-3/4 thick doors: For 1-3/8 thick doors: 5/8 Flat panel and 1-1/4 raised panels 1/4 Flat panel and 7/8 raised panel 2. Gaps between panel and sticking or molding profiles are not acceptable. All gaps must be filled before shipping. D. Pocket Doors: 1 3/8 inches thick and 1 3/4 inches thick, MDF construction, sizes as noted on Door Schedule with panel/molding design as selected by Interior Designer/Owner. 1. MDF Pocket/Slider doors are to be ordered with top woodeges in addition to the side keyed or concealed woodedges. D. MDF Louvers: Manufacturers Standard solid MDF, Stile and Rail, louvers with individual 2-1/4 slats (1-3/8" & 1-3/4" thick doors). Less than 2-1/4 true louver blades are not to be used. E. MDF False Louver: Manufacturers standard solid MDF, Stile and Rail, louvers with false louver slats (1 3/8 & 1-3/4 thick doors). Louver slats face down in both directions with a minimum 1-9/16 louver face. F. Glass Doors: Any glass included in the doors must be tempered or laminated glass. Doors shall be quoted and manufactured in TRUE DIVIDED LITE construction unless noted otherwise. 2.3 ACCESSORIES Wood Jambs: When applicable wood jambs may be requested to be supplied by manufacturer in knocked down or prehung units. Wood jambs should be stapled AND screwed together for additional durability due to the solid weight of the doors. 2.4 FABRICATION A. Fabricate Non-Rated Doors in compliance with NWWDA. B. Fabricate Fire Rated Doors in compliance with NWWDA and Warnock Hersey/UL/QAI requirements. Attach Fire-Rating Label to door-edge for rating to be acknowledged. C. Factory pre-fit and bevel doors. Pre fit fire-rated doors in accordance with NFPA 80. D. Optional Factory pre-machine doors for hardware that is not surface-applied (machining normally required on all fire doors unless dealer is licensed through Intertek). Templates are required 2.5 FINISHING A. Factory-prime doors in compliance with AWI Quality Standard Section Priming
5 should be with a low VOC water based primer. Minimum two coats are required. Request finishing instructions from manufacturer before painting doors. Finish doors on all six sides to maintain warranty. PART 3-EXECUTION 3.1 EXAMINATION A. Examine doors and install door frames before hanging doors. Confirm that frames comply with type, size, location and swing requirements and are installed plumb and square. B. Inspect doors for damage, manufacturing defects or pre-finish inconsistency. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Prefit doors to frames and machine for hardware to whatever extent not previously worked at factory as required for proper fit and uniform clearance at each edge. 3.3 INSTALLATION A. Install door in accordance with manufacturer's recommendations. B. Installation of doors should be done by skilled installer who has read the manufacturers warranty coverage. Do not over tighten hinge screws, and see manufacturer's recommendations for installation of hinges. Doors may be applied with auto body filler and sanded if lines appear near hinges. 3.4 ADJUSTING AND PROTECTING A. Adjust doors as required and leave in proper operating condition. B. Inform General Contractor of proper procedures required to protect installed doors from damages or deterioration until acceptance of entire project. C. Repair any scratches and/or gouges with auto body filler and sand with sandpaper for smooth finish. This will not affect the warranty of the doors.
SECTION 062043 FIRE-RATED WOOD JAMBS
SECTION 062043 FIRE-RATED WOOD JAMBS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. [Solid wood] [Particle board] fire-rated interior door[ and sidelight] frames. 2. Intumescent/wood fire-rated interior
More informationEggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art
D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries
More informationINSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationDIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
More informationC. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.
SECTION 081216 - INTERIOR ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationBASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401
BASIC FIRE DOOR REQUIREMENTS SHEET NO. 401 Fire door openings are classified by their locations in the building. The location determines the length of exposure protection required, based on the potential
More informationINSTALLATION INSTRUCTIONS for Bifold Doors (JII103)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationTurning nature s beauty into works of art
f l u s h d o o r s Eggers 5-ply flush doors are the very embodiment of form marrying function - extraordinary beauty and exceptional durability. We are able to produce a variety of custom architectural
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More information09 00 03 GENERAL PROVISIONS
09 00 03 GENERAL PROVISIONS A. For renovation projects, consider the building s character and existing finishes. All material patches should blend as closely as possible. Some buildings on campus have
More informationTechnical Data Honeycomb Door Leaf 8-1-99
8--99 8-/8 8-7/8 B 8-/4 A A Dim. A Leaf Width B ELEVATION F DESIGN Vertical edge seams mechanically interlocked Square hinge and lock edges 4-/ x.4 full mortise hinge prep Gov. 60/6 cyl lock prep...prefix
More informationCLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
More informationFF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1
FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1 Issue Date: 3/3/2009 Each furniture item scheduled in this specification manual is assigned a "key" code; each key code is crossreferenced
More informationActive and Passive Sash Replacement
for Andersen Gliding Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete the procedure, call Andersen at 1-888-888-7020 for
More informationCLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
More informationArchitectural Casework 06400-01. 1.01 Description of Work
06400-01 1.01 Description of Work A. Extent of each type of architectural millwork and casework as indicated on drawings. Types of architectural casework shall include both stained and plastic laminated
More informationPre-Cut Sauna Specifications
Pre-Cut Sauna Specifications When to specify a Pre-Cut Liner Sauna: Please review diagrams at the beginning of these specs. Pre-Cut saunas are best suited for projects that require the four walls and ceiling
More informationSECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
More informationSECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
More informationA. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section: SPECIFIER NOTE:
This is a guidance document with sample specification language intended to be inserted into project specifications on this subject as appropriate to the agency's environmental goals. Certain provisions,
More informationSECTION 08740 ELECTRO-MECHANICAL HARDWARE
SECTION 08740 ELECTRO-MECHANICAL HARDWARE PART 1 - GENERAL 1.1 SUMMARY: A. Section Includes: 1. Items known commercially as electro-mechanical hardware, required for special applications at limited doors.
More informationRACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES
1807 Elmwood Avenue, Suite 275 Buffalo, New York 14207 (800) 543-5155 RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES Fiberesin Wall System Provide materials and labor to complete courts
More informationCore and Frame Details
and Frame Details February, 2014 Contents Architectural Flush Wood Door Codes 1-2 Performance Standards 3 GRAHAM SUPREME DOOR GSD SR 35-40 4 GSD SR 41-45 5 GSD SR 31, 33, 39, and 44 6 GSD SR 46-47 7 GRAHAM
More informationCustomer Service 800.780.8889 or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips
reflect your style TM Customer Service 800.780.8889 or visit us online at smithnoble.com Wood Shutters Step by Step Installation Troubleshooting Tips Easy Care Instructions STEP 1 Your New Shutter Thank
More informationSECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex
(Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide
More informationSECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
More informationHOW TO INSTALL A BEAUTIFUL NEW KITCHEN
HOW TO INSTALL A BEAUTIFUL NEW KITCHEN Easy to follow step-by-step kitchen cabinet installation TOOL AND MATERIAL LIST Hammer Pry bar Screwdriver Phillips Flathead Level Tape measure Pencil Straight edge
More informationRACO Interior OfficeFronts. SolutionsII Typical Details. SolutionsII
SolutionsII 1 SolutionsII Product Typical Overview Details I. GENERAL DESCRIPTION Work Included: Furnish all necessary materials, labor and equipment for the complete installation of interior aluminum
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationENTRANCE MATS & GRIDS
152 Rollins Avenue #102 Rockville, MD 20852 800-762-9010 240-780-3309 (f) http://www.americanfloormats.com ENTRANCE MATS & GRIDS PART I - GENERAL 1.01 Summary A. This section includes the following types
More information07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
More informationDIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
More informationCOMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
More informationPERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
Architectural Testing PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Mahogany Entry Door PRODUCT TYPE: 6' x 8' Double Outswing Hardwood TDL Door with Half Circle TDL Transom
More informationSECTION 10670 STORAGE SHELVING. Copyright 2007-2011 ARCAT, Inc. - All rights reserved
1 SECTION 10670 STORAGE SHELVING Copyright 2007-2011 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Vinyl-coated ventilated shelving. B. Laminated closet systems. C. Specialty
More informationGigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
More informationSash Replacement Guide
for Andersen 200/400 Series Awning Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete this procedure, call Andersen at 1-888-888-7020
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationGuide Specifications for Maple Flooring Systems
Guide Specifications for Maple Flooring Systems MFMA Guide Specification for Resilient Pre-Engineered Fixed Panel System Purpose This Guide Specification is designed to assist in the production of actual
More informationREPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012
TEST REPORT REPORT NUMBER: 100758576MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 RENDERED TO Fire Door Caulk LLC.
More informationAutomatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 aaadm@aaadm.com Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
More informationquality door and window systems for metal buildings
quality door and window systems for metal buildings knock-down door systems Features and Benefits: Galvanized Doors and Frames Insulated Door Cores Textured Steel Door Faces Completely Reversible (non-handed
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationSECTION 10 5700 WARDROBE AND CLOSET SPECIALTIES PART 1 - GENERAL
SECTION 10 5700 WARDROBE AND CLOSET SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1
More informationSECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: info@alpolic.com www.alpolic-northamerica.com This MANU-SPEC utilizes
More information2. Division 05 Structural Steel Framing for steel framework requirements
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
More informationSapa: SECTION 05520 ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS
PART 1 GENERAL Sapa: SECTION 05520 ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS 1.1 SECTION INCLUDES A. Aluminum and Glass Handrails B. Aluminum Railings 1.2 RELATED SECTIONS A. Section 05700 - Ornamental
More informationRepair and Remodeling Estimating Methods. 4th Edition. RSMeans
Brochure More information from http://www.researchandmarkets.com/reports/2214808/ Repair and Remodeling Estimating Methods. 4th Edition. RSMeans Description: This estimating guide for repair and remodeling
More informationB. Related categories: The following categories contain requirements that relate to this section:
ORIENTED STRAND BOARD PART I. - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
More informationn Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame
Weather Fin and bulb help keep bad weather outside and good air inside Windows: n Many light kits are available 1-LU 4 X 48 1-LE 16 X 16 1-LA 20 X 24 1-LI 20 X 24 1-B 22 X 36 1-LW 16 X 16 W/GRID 9-LB 22
More informationSECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationYour Company Name. Your Company Address Your City, State, Zip Your Phone Number Your Email Address. Project Information
Your Company Address Your City, State, Zip Your Phone Number Your Email Address Customer Information John Smith 0 Sandy Lane Blvd Tampa, FL 3342 Project Information Estimate Prepared By: Jones Estimating
More informationINSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW
Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationREDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES
REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES Tools Required Tape Measure Hammer Slotted Screw Driver #2 & #3 Philips Screw Driver 3-4 Foot Level 12 Pry Bar Cold Chisel
More informationSteel Door Frame Installation in Steel Stud Construction
Steel Door Frame Installation in Steel Stud Construction For use with the Steel Door Institute (SDI) video How to Install a Steel Door Frames in Steel Stud Construction This manual gives you step-by-step
More informationA Complete Solution CREATING WALLS THAT DEFINE SPACE
A Complete Solution CREATING WALLS THAT DEFINE SPACE COMPANY HISTORY CLIPPER WALL Clipper partitions are part of the Saint- Gobain Group, one of the worldwide leaders in the construction products industry.
More informationFire-Rated Doors and Hardware. A Guide to Field Inspection
Fire-Rated Doors and Hardware A Guide to Field Inspection Foundation s Mission To promote secure and safe openings that enhance life safety Awareness To be a source of information through awareness campaign
More informationDIY CABINET REFACING INSTALLATION GUIDE
DIY CABINET REFACING INSTALLATION GUIDE CABINET REFACING INSTALLATION Are you ready to reface your outdated cabinets? This guide will show you how to install your new Facelifters Cabinet Refacing Products
More informationUnderwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
More information10615/TRE BuyLine 9964 A new way to look at walls.
10615/TRE BuyLine 9964 A new way to look at walls. TrendWall Long Term Solutions for Facilities on the It s all here. Consider TrendWall your alternative to permanent walls. It s a movable wall system
More information9300BC SERIES Light Commercial Door Closer
Light Commercial Door Closer general information The 9300BC is a durable, economically priced door closer designed for commercial exterior and interior doors such as storefront and industrial applications.
More informationWhy Steel? Performance Study of Steel Doors and Frames Compared to Other Materials. September 2015. Sponsored by SDI, HMMA, CSDMA
Why Steel? Performance Study of Steel Doors and Frames Compared to Other Materials September 2015 Sponsored by SDI, HMMA, CSDMA CANADIAN STEEL DOOR MANUFACTURERS ASSOCIATION L'ASSOCIATION CANADIENNE DES
More informationHMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF
More informationSECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationINSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg
Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to
More informationA ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS
A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS International Code Council National Fire Protection Association Underwriters Laboratories Inc. 5203 Leesburg Pike, Suite 600 1 Batterymarch
More informationSECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
More informationENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
More informationBarewood Octagon and Elongated Windows Installation Instructions
Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationThe replacement or modification of existing windows shall comply with the following requirements:
City of La Habra Heights Building Division 1245 N. Hacienda Road La Habra Heights, CA 90631 Office: (562) 694-6302 ext. 228 Fax: (562) 690-5010 WINDOW REPLACEMENT 2010 CALIFORNIA RESIDENTIAL CODE (CRC)
More information2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots
2.02 Standard Specifications General Entrances Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum entrance doors, door frames and hardware as shown
More information2014 Masonite. Bolection. the beautiful door. premium interior doors. MIC-13320-INT-2014-BolectionBro-123013.indd 1
2014 Masonite Bolection premium interior doors the beautiful door MIC-13320-INT-2014-BolectionBro-123013.indd 1 12/30/13 2:55 PM MASONITE Bolection COLLECTION 2 Series 201 with RM1 Moulding MIC-13320-INT-2014-BolectionBro-123013.indd
More informationDoors and frames. Technical data manual 2015 rev. 8/17/15
Doors and frames Technical data manual 2015 rev. 8/17/15 Technical data manual Main table of contents NAVIGATE VIA: A) Rollover links in each TOC (each item below is a link), B) Bookmarks on the left,
More informationSteel Door Institute. Fire Rated Doors and Frames
Steel Door Institute Fire Rated Doors and Frames 1 1. Nomenclature and Overview 2. Fire Rated Frames 3. SDI 118 4. Fire Rated Doors 5. Fire Rated Hardware 6. Specialty Products Table of Contents 2 Fire
More informationInstallation Instructions and Ordering Information
The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using
More informationCONTEMPORARY - TRANSITIONAL RECEPTION STATIONS
Reception stations, the first impression expressed to visitors in your office. Transitional styling to coordinate with your other office settings, available in a selection of 16 walnut, cherry, oak, maple
More informationMold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
More informationOffice of the State Fire Marshal. Fire Rated Doors
Office of the State Fire Marshal Fire Rated Doors Fire Rated Doors These doors serve a purpose. They are manufactured in a way that is to help reduce the spread of fire and smoke. Fire rated doors allow
More informationCONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE
CONCEALED BEARING HINGES StANLEy ARCHItECtuRAL HARDwARE STANLEY ARCHITECTURAL HARDWARE TABLE OF CONTENTS Page Table of contents...2 Company history...2 5 knuckle concealed bearing design...3 Full mortise
More informationENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationCalvert USA, Inc. Attic Stairs
Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,
More informationEcoTouch Insulation with PureFiber Technology
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationDelivery Split delivery Off Hr delivery Store off site To tailgate To floor Accepted by
ARCHITECTURAL WOODWORK QUALITY STANDARDS SPECCHEK INSERT MODULAR CABINETS AWI Grades Transparent Fin. Opaque Fin. Laminate clad By room By floor By item Size Width Height Thickness Construction Flush overlay
More informationST. MONICA FOOD PANTRY HOUSTON, TEXAS
PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,
More informationPDQ HINGE SUGGESTED ARCHITECTURAL SPECIFICATIONS METICULOUSLY MANUFACTURED, THE PDQ HINGE IS AVAILABLE IN 3 BASE METALS: SPECIFICATIONS HINGE SERIES
Commercial Hinges PDQ HINGES PDQ wants to be your total one source supplier of contract hardware materials. The introduction of a high quality PDQ hinge is another step in this direction. PDQ hinges are
More informationDESIGN CLARIFICATION (DC)
DESIGN CLARIFICATION (DC) Owner: Victor Valley Wastewater Reclamation Authority Date: 03/03/2015 Contractor: W M Lyles Carollo Project No.: 8299A.20 Project Name: Subregional WRPs DC No.: 001 DC Title:
More informationSCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
More informationOld Goats, Inc. and Screendoors.com WOOD SCREEN DOOR
and Screendoors.com WOOD SCREEN DOOR I. LIMITED Satisfaction Guaranteed WARRANTY I. OLD GOATS, INC. SCREEN DOOR LIMITED WARRANTY This Limited Warranty applies only to wood screen doors ( Covered Products
More informationClass A Office Buildings Commercial Facilities College and University Campuses K-12 Buildings Healthcare Facilities Government & Military Structures
Bringing New Light to Interior Architecture Expansive New Light Frameworks brings new light to interior architecture with doors, frames and windows that pair custom and standard glazing options with an
More informationImportant Information for Installer & Homeowner
Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side
More informationInspecting to a higher standard.
Inspecting to a higher standard. Rob Hopkin Silver Spring, MD 20902 Monday, June 2, 2014 ProTec Inspection Services Inc. 19736 Selby Ave Poolesville, MD 20837 301-972-8531 www.protec-inspections.com rob@protec-inspections.com
More informationATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS
ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS 1.0 GENERAL INFORMATION Structural Interior Design includes all building related elements and components generally part of the building itself,
More information