ТОП-0.66 and ТШП-0.66 CURRENT TRANSFORMERS

Size: px
Start display at page:

Download "ТОП-0.66 and ТШП-0.66 CURRENT TRANSFORMERS"

Transcription

1 ТОП-0.66 an ТШП-0.66 CURRENT TRANFORMER ТОП-0.66 an ТШП-0.66 current transformers are intene for transmission of measuring signals to measurement evices an are applie in electricity metering an counting circuits of a.c. installations of 0 z frequency an up to 0.66 kv (inclusive) rate voltage. Transformers comply wit te requirements of GOT 6- stanar. Climatic version CT as in accorance wit IEC :2 stanar. Transformers are resistant to externally inuce mecanical stresses as for M2 mecanical performance group in accorance wit GOT an are rate for installation at te altitue of not more tan 000 m above sea level. As to installation conitions on worksite, te transformers are incorporate ones an tey allow to be installe in watever attitue position. Insulation termal-enurance class E as to GOT Magnetic cores of te ; 0.2 an 0.2 accuracy class current transformers for 0 A primary currents are of two esigns: - mae of electric steel; 2 - composite type mae of electric steel an nanocrystalline alloy. Magnetiс cores of 0.2 an 0.2 accuracy class are of te 2n esign multiple-unit of electric steel an nanocrystalline alloy. Inex of magnetic core esign variant is inclue into te transformer esignation. Winow type current transformers ТШП-0.66 for 0 A primary currents are of two esigns epening on winow size: -I - 23x03 mm (current transformers for A primary currents); -II - 38x8 mm (current transformers for 000 A primary currents); -III - 60x3 mm (current transformers for A primary currents). Magnetic cores of transformers are mae of electric steel. Te winow esign variant number also is a part of ientification coe of current transformer. econary wining contact terminals are covere wit a transparent plastic cap, wic, if necessary, can be seale up. Transformers are subject to inspection by te Public tanars Boy representatives. ТОП-0.66 an ТШП-0.66 current transformers esign provies ouble contact terminals allowing to carry out control cecks at facilities witout loa-off an, for ; 0.2 an 0.2 accuracy class a seale-up contact terminal for connection to a counter coil, wic prevents electricity stealing. tructural parts of te transformers cases are mae of arly ignitable plastic. As to protection against electric-sock azar te transformers belong to 0 class in accorance wit GOT an ave IP00 protection egree in accorance wit GOT

2 Uner a Customer's orer ТШП current transformers for 600 an 800 A primary currents can be fitte wit an aluminium of imensions an mass given in Figure 6, an ТШП current transformers for 000, 00 an 0 A primary currents wit a copper or aluminium of imensions an mass as to Figure. Basic specifications of te transformers Description voltage, kv seconary current, А Rater frequency, z primary current, А Norm or 60 0; 20; ; 0; 0; ; 00; 0; ; ; ; 00; 600; 800; 000; ; 00; 0; 0; 0 ; 0; ; 20; ; 0.; ; 0.2; 0.2 seconary loa, В А Accuracy class Overall, mounting imensions an mass of te transformers 2 2 oles И И Fig. ТОП series transformers for A primary currents 9

3 Overall, mounting imensions an mass of te transformers oles B 28 2 Fig. 2 ТОП series transformers for, an A primary currents И И B 2 Fig. 3 ТШП series transformers for, an A primary currents 20 Fig. ТШП series transformers for 600 an 800 A primary currents

4 И2 И Л2 2 2 Fig. ТШП series transformers for 000, 00 an 0 A primary currents oles Mass 0. kg 38 =8 Fig. 6 Busbar for 600 an 800 A primary currents Ø oles Ø =0 Mass.8 kg (copper) 0.8 kg (aluminium) Fig. Busbar for 000, 00 an 0 A primary currents 2

5 TRANFORMER ТШП-0,66- У3 ТУ BY b 2 a ТШП-0, c Fig. 8 ТШП series transformers for...0 A primary currents B Overall, mounting imensions an mass of te transformers ТШП-0,66 imensions in millimeters Type esignation primary current, А ТШП Accur acy seconary Fig class loa, V А 0. 0.; 0.; ; 0. 0; ; 20 ; 0.; ; 0; ; 20; В * 2.**.68* 2.8**.33* 2.3**.3* 2.63**.38* 2.8** ; 0; ; 20; * wit aluminum ** wit copper ТШП Mass, kg Mass, kg witout wit 0. ; 0.2;

6 Overall, mounting imensions an mass of te transformers ТОП-0.66 imensions in millimeters Type esignation Accur primary -acy seconary current, А class loa, V А 0; 20; ; 0; 00; ; 0.; ; ; 20 ТОП ; ТОП ; 20; ; 0; ; 00; 0 0 0; 20; ; 0; ; 00; 0; 0 ; ; 0.; ; 0. Fig В 2 Mass, kg Mass, kg witout wit ; ; 20; 0 0; ; 20 0; ; 20; 0 0; ; 20 0; ; 20; 0; ; ; ; ;

7 Overall, mounting imensions an mass of te transformers imensions in millimeters Type esignation ТШП-0.66-I Accur seconary acy primary Fig loa, V А current, А class 800 ; ; 0.; ; 0; ; 0; ; 0 ; 0; ; 0 ; 0; ; 0 ; 0; ; 0 ; 0; ; 0 00 ТШП-0.66-II ТШП-0.66-III ; 0.; В b a c 2 ; 0; ; ; 0; Mass, kg ample of notation (to place an orer, or to refer to) for a typical transformer of 0 A primary current, of A seconary current, of VA seconary loa rating, of accuracy class: Current transformer ТОП / У3 ТУ РБ Te same, but wit a composite magnetic core: Current transformer ТОП / У3 ТУ РБ Example of reference esignation of te esign transformer wit te II winow size (38 8 mm), wit rate primary current 800 A, wit seconary current A, wit accuracy class, wit seconary loa V A, wen orering an in te ocumentation of oter prouct: Current transformer ТШП-0.66-II---800/ У3 ТУ BY 00226/ (were ТУ РБ = Tecnical pecifications of te Republic of Belarus). 2

iglidur PRT Slewing Ring Bearing

iglidur PRT Slewing Ring Bearing igliur igliur Slewing Ring Bearing Stanar range Completely maintenance-free Easy installation, intercangeable sliing pas ig wear resistance For ig loa capacity, ig stiffness Available as stainless steel

More information

Products no longer available

Products no longer available Technical ata sheet R6..R haracterize control valves, 2-way, with flange PN 6 for open an close col an warm water systems for moulating control on the water sie of air-hanling an heating systems air bubble-tight

More information

Tripping Current and Short Circuit Current of High Voltage Tester

Tripping Current and Short Circuit Current of High Voltage Tester Tripping Current an Short Circuit Current of igh oltage Teter Xu hezhun Wang Keqin Abtract: Tripping current an hort circuit current are iportant technical pecification of high voltage teter, an frequently

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

your reliable partner EAS -Compact Backlash-free Torque Limiting Clutches K.490.V14.EN

your reliable partner EAS -Compact Backlash-free Torque Limiting Clutches K.490.V14.EN ES -Compact Backlash-free Torque Limiting Clutches K.490.V4.EN www..com We safeguar the movements of this worl Specialists for power transmission for more than a century mayr power transmission is one

More information

Section 3.3. Differentiation of Polynomials and Rational Functions. Difference Equations to Differential Equations

Section 3.3. Differentiation of Polynomials and Rational Functions. Difference Equations to Differential Equations Difference Equations to Differential Equations Section 3.3 Differentiation of Polynomials an Rational Functions In tis section we begin te task of iscovering rules for ifferentiating various classes of

More information

Lead Screws with Plastic Nuts. Resin Lead Screws. Combination of Shaft nominal dia. & Lead

Lead Screws with Plastic Nuts. Resin Lead Screws. Combination of Shaft nominal dia. & Lead Screws with Plastic Nuts SUS3SUS33 MRH MRH eatures he Shaft is manufacture from SUS3 or SUS33, which gives excellent corrosion resistance. Wie range of combination of Shaft ia. an are available. MRH incorporates

More information

11 CHAPTER 11: FOOTINGS

11 CHAPTER 11: FOOTINGS CHAPTER ELEVEN FOOTINGS 1 11 CHAPTER 11: FOOTINGS 11.1 Introuction Footings are structural elements that transmit column or wall loas to the unerlying soil below the structure. Footings are esigne to transmit

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current

More information

BLS 100 Orifice Plate DIN 19206

BLS 100 Orifice Plate DIN 19206 E91 2006 1Orifice Plate, Orifice Flange, Meterrun, Restriction Orifice Application Flow rate measurement of aggressive an nonaggressive meia particularly for large pipelines. Construction Orifice plate

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

The complete range of consumer switchboards and switchgear

The complete range of consumer switchboards and switchgear Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial

More information

Pluvia Product and Installation Guide

Pluvia Product and Installation Guide Pluvia Prouct an Installation Guie Vali from 1. August 2011 Series 5 Pluvia outlets Page 3 Series 5 Outlet accessories Page 4 Series 7 Pluvia outlets Page 4 Series 7 Pluvia accessories Page 9 Series 7

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Fault location on power cables. Fault location on power cables

Fault location on power cables. Fault location on power cables Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables

More information

INFLUENCE OF GPS TECHNOLOGY ON COST CONTROL AND MAINTENANCE OF VEHICLES

INFLUENCE OF GPS TECHNOLOGY ON COST CONTROL AND MAINTENANCE OF VEHICLES 1 st Logistics International Conference Belgrae, Serbia 28-30 November 2013 INFLUENCE OF GPS TECHNOLOGY ON COST CONTROL AND MAINTENANCE OF VEHICLES Goran N. Raoičić * University of Niš, Faculty of Mechanical

More information

Rack & Pinion Lubrication Systems

Rack & Pinion Lubrication Systems Page Lubricator 125 cm 3 ZE-2 Lubricator 475 cm 3 ZE-3 Selection of the Lubrication for Rack Drives ZE-4 Lubrication System ZE-5 6 Felt Gear ZE-7 8 Lubrication Equipment, Accessories ZE 9 Lubricating Systems

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

CMOS 1.8 V to 5.5 V, 2.5 2:1 Mux/SPDT Switch in SOT-23 ADG719

CMOS 1.8 V to 5.5 V, 2.5 2:1 Mux/SPDT Switch in SOT-23 ADG719 a FEATURE 1.8 V to 5.5 ingle upply 4 (Max) On Resistance.75 (Typ) On Resistance Flatness Automotive Temperature Range: 4 C to +125 C 3 db Bandwidth > 2 MHz Rail-to-Rail Operation 6-Lead OT-23 Package and

More information

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73. Pluvia Syphonic roof rainage system Description Outlets Page 62 Pluvia outlets 12 l Contact foil Page 65 Accessories Page 65 Pluvia outlets 25 l Outlets Page 68 Accessories Page 69 Pluvia outlets 45/60/100

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

L4. Pipes Materials and Loads

L4. Pipes Materials and Loads The Islamic University of Gaza- Civil Engineering Department SanitaryEngineering- ECIV 4325 L4. Pipes Materials an Loas Base on Dr. Fahi Rabah lecture notes Pipes Materials an loas Materials use for pipes:

More information

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World Catalogue 2002 Automatic capacitor banks Building a New Electric World 0Contents Power factor correction 2 Power factor equipment selection guide 3 General technical data 4 Capacitors and banks 50 z 6

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

Metal Film Resistors, Military, MIL-R-10509 Qualified, Precision, Type RN and MIL-PRF-22684 Qualified, Type RL

Metal Film Resistors, Military, MIL-R-10509 Qualified, Precision, Type RN and MIL-PRF-22684 Qualified, Type RL Metal Film Resistors, Military, Qualified, Precision, Type RN and Qualified, Type RL FEATURES Very low noise (- 40 db) Very low voltage coefficient (5 ppm/v) Controlled temperature coefficient Flame retardant

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

An Alternative Approach of Operating a Passive RFID Device Embedded on Metallic Implants

An Alternative Approach of Operating a Passive RFID Device Embedded on Metallic Implants An Alternative Approach of Operating a Passive RFID Device Embee on Metallic Implants Xiaoyu Liu, Ravi Yalamanchili, Ajay Ogirala an Marlin Mickle RFID Center of Excellence, Department of Electrical an

More information

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Customer: Cardiff Hospital NHS (United Kingdom) Machine: Customer: Cardiff Hospital NHS (United Kingdom) Machine: Bench for leak test Model: Easy TS Page 1 of 7 Date: 6 th March 2012 1. Introduction. Easy TS is a compact and reliable table top bench designed

More information

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay

More information

Achieving quality audio testing for mobile phones

Achieving quality audio testing for mobile phones Test & Measurement Achieving quality auio testing for mobile phones The auio capabilities of a cellular hanset provie the funamental interface between the user an the raio transceiver. Just as RF testing

More information

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B, Accessories Temperature Sensors for Injection Molding Types 6192B, 6193B, 6194B, 6195B Temperature sensors for measuring the contact temperature directly in the cavity at the surface of the solidified

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Data Center Power System Reliability Beyond the 9 s: A Practical Approach

Data Center Power System Reliability Beyond the 9 s: A Practical Approach Data Center Power System Reliability Beyon the 9 s: A Practical Approach Bill Brown, P.E., Square D Critical Power Competency Center. Abstract Reliability has always been the focus of mission-critical

More information

How To Evaluate Power Station Performance

How To Evaluate Power Station Performance Proceeings of the Worl Congress on Engineering an Computer Science 20 Vol II, October 9-2, 20, San Francisco, USA Performance Evaluation of Egbin Thermal Power Station, Nigeria I. Emovon, B. Kareem, an

More information

S & C E L E C T R I C C O M P A N Y

S & C E L E C T R I C C O M P A N Y Descriptive Bulletin 811-30 September 11, 2006 Supersees Descriptive Bulletin 811-30 ate 5-12-03 2006 Here Are Five Reasons Why Loabuster Is the Better Way: 1 Range S&C s Loabuster unlike loabreak cutouts

More information

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS

CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS ADVANCED MATERIALS THE KEY TO PROGRESS CURRENT TRANSFORMERS FOR ELECTRONIC WATTHOUR METERS VACUUMSCHMELZE GmbH & Co. KG (VAC) is one of the worldwide

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

A sophisticated design for a demanding field. prima series

A sophisticated design for a demanding field. prima series A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally

More information

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation IOSR Journal of Engineering (IOSRJEN) ISSN (e): 2250-3021, ISSN (p): 2278-8719 Vol. 04, Issue 01 (January. 2014), V6 PP 01-12 www.iosrjen.org Paper on Basbar Trunking System for Electrical Supply to Industrial

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

1 Introduction to the Recommendations and their Application Principles

1 Introduction to the Recommendations and their Application Principles 1 Introuction to the Recommenations an their Application Principles 1.1 National an International Regulations for Piling Wors (1) Since the implementation ofdin EN 1997-1:2009-09: Eurocoe 7: Geotechnical

More information

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Safety Management System. Initial Revision Date: Version Revision No. 02 MANUAL LIFTING

Safety Management System. Initial Revision Date: Version Revision No. 02 MANUAL LIFTING Revision Preparation: Safety Mgr Authority: Presient Issuing Dept: Safety Page: Page 1 of 11 Purpose is committe to proviing a safe an healthy working environment for all employees. Musculoskeletal isorers

More information

U15. Data sheet. Force Transducer. Special features. Mounting dimensions of the connection variants. B2231-3.0 en

U15. Data sheet. Force Transducer. Special features. Mounting dimensions of the connection variants. B2231-3.0 en U15 orce ata sheet Special features - Tensile/compressive force transducer - Nominal (rated) forces 2.5 kn to 1 MN - lass 0.5 per to ISO 376 (in conjunction with K calibration certificate) - Electronic

More information

Medium voltage insulator

Medium voltage insulator Medium voltage insulator Line post insulators type R-ET Commercial designation LPI 24 N ET 1) LPI 24 L ET/5 1)2) LPI 24 L ET/6 1)2) LPI 38 L ET 1) esignation acc. to IEC 720 R 12,5 ET 125 N R 12,5 ET 125

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

DIFFRACTION AND INTERFERENCE

DIFFRACTION AND INTERFERENCE DIFFRACTION AND INTERFERENCE In this experiment you will emonstrate the wave nature of light by investigating how it bens aroun eges an how it interferes constructively an estructively. You will observe

More information

Heat Exchangers. Heat Exchanger Types. Heat Exchanger Types. Applied Heat Transfer Part Two. Topics of This chapter

Heat Exchangers. Heat Exchanger Types. Heat Exchanger Types. Applied Heat Transfer Part Two. Topics of This chapter Applied Heat Transfer Part Two Heat Excangers Dr. Amad RAMAZANI S.A. Associate Professor Sarif University of Tecnology انتقال حرارت کاربردی احمد رمضانی سعادت ا بادی Autumn, 1385 (2006) Ramazani, Heat Excangers

More information

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l Geberit Pluvia Syphonic roof rainage system Description Overview Page 42 Geberit Pluvia outlets 6 l Outlets Page 43 Contact foil Page 43 Outlets Page 44 Geberit Pluvia outlets 14 l eating element Page

More information

KITZ Steel Ball Valves Floating Ball Design

KITZ Steel Ball Valves Floating Ball Design IZ Steel all Valves loating all esign ontents esign an Inspection Stanars IZ Prouct oing Prouct Range esign eatures 0 IZ YPI P all Seats ow mission esign eatures Pressure-emperature Ratings lass / 00 ast

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

CMOS Low Voltage 2.5 Ω Dual SPDT Switch ADG736L

CMOS Low Voltage 2.5 Ω Dual SPDT Switch ADG736L CMO Low Voltage 2.5 Ω ual PT witch AG736L FEATURE 1.8 V to 5.5 V single supply 2.5 Ω (typical) on resistance Low on-resistance flatness Guaranteed leakage performance over 40 C to +85 C 3 db bandwidth

More information

CMOS 1.8 V to 5.5 V, 2.5 Ω 2:1 Mux/SPDT Switch in SOT-23 ADG719

CMOS 1.8 V to 5.5 V, 2.5 Ω 2:1 Mux/SPDT Switch in SOT-23 ADG719 CMOS 1.8 V to 5.5 V, 2.5 Ω 2:1 Mux/SPT Switch in SOT-23 AG719 FEATURES 1.8 V to 5.5 V single supply 4 Ω (max) on resistance 0.75 Ω (typ) on resistance flatness 3 db bandwidth > 200 MHz Rail-to-rail operation

More information

Control Stations in Sheet steel or Stainless Steel Series 8125

Control Stations in Sheet steel or Stainless Steel Series 8125 ontrol Stations in Sheet steel or Stainless Steel www.stahl.de > in electropolished stainless steel 1.4404 (ISI 316L) or zinc-galvanised sheet steel painted > 6 basic enclosure sizes with different enclosure

More information

MATHEMATICS FOR ENGINEERING DIFFERENTIATION TUTORIAL 1 - BASIC DIFFERENTIATION

MATHEMATICS FOR ENGINEERING DIFFERENTIATION TUTORIAL 1 - BASIC DIFFERENTIATION MATHEMATICS FOR ENGINEERING DIFFERENTIATION TUTORIAL 1 - BASIC DIFFERENTIATION Tis tutorial is essential pre-requisite material for anyone stuing mecanical engineering. Tis tutorial uses te principle of

More information

Control Stations Made of Polyester Resin Series 8146

Control Stations Made of Polyester Resin Series 8146 ontrol Stations Made of Polyester Resin www.stahl.de > s made of glass-fibre reinforced polyester resin > 8 basic enclosure sizes with various enclosure heights > an be combined to larger units > Equipped

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

Vrieswijk, T & Srinivasan,A Amerongen,NL, 25 januari 2012

Vrieswijk, T & Srinivasan,A Amerongen,NL, 25 januari 2012 Theory Current Transformers Vrieswijk, T & Srinivasan,A Amerongen,NL, 25 januari 2012 Theory Current Transformers 25 januari 2012 Topics - Theory of current transformers (CTs) - Equivalent Circuit for

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Pressure. Pressure. Atmospheric pressure. Conceptual example 1: Blood pressure. Pressure is force per unit area:

Pressure. Pressure. Atmospheric pressure. Conceptual example 1: Blood pressure. Pressure is force per unit area: Pressure Pressure is force per unit area: F P = A Pressure Te direction of te force exerted on an object by a fluid is toward te object and perpendicular to its surface. At a microscopic level, te force

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Capacitor Voltage Transformer. Answers for energy.

Capacitor Voltage Transformer. Answers for energy. Capacitor Voltage Transformer Answers for energy. Capacitor Voltage Transformer Siemens Capacitor Voltage Transformers are based on technology from Trench, a recognized world leader in the design and manufacture

More information

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Transducers T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V Velocity transducers B A L A N C I N G M A C H I N E S B A L A N C I N G M A C H I N E S Principle of operation A voltage proportional to the velocity

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES xl 3 configurable assemblies IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES XL 3 configurable assemblies guide to migration from IEC 60439 to IEC 61439

More information

A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE. No.107. Guide to the calibration and testing of torque transducers

A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE. No.107. Guide to the calibration and testing of torque transducers A NATIONAL MEASUREMENT GOOD PRACTICE GUIDE No.107 Guie to the calibration an testing of torque transucers Goo Practice Guie 107 Measurement Goo Practice Guie No.107 Guie to the calibration an testing of

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

Marine Catalogue 2013

Marine Catalogue 2013 Marine Catalogue 2013 escription Moel Packaging Hep 2 O Barrier Pipe Re Conuit 15 L = 50 mtr WBCL010305A orer pipe by unit (coil) not by meter 22 L = 50 mtr WBCL010306A straight connector 15 10 pieces

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current

More information

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

SF 6 Gas Insulated Switchgear Type SDF for 170 kv Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

IFC 070 Technical Datasheet

IFC 070 Technical Datasheet IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

HVDC Light Cables. Submarine and land power cables

HVDC Light Cables. Submarine and land power cables HV Light Cables Submarine and land s The HV Light s to offshore platform The light and robust HV Light s can be laid with very cost effecient methods HV Light System HV Light is a transmission system in

More information

STANDARD MICRO-D CONNECTORS

STANDARD MICRO-D CONNECTORS STANDARD MICRO-D CONNECTORS RECTANGULAR CONNECTORS Pigtail connector - Metal shell.............................. 56 Pigtail connector - Low profile - Metal shell.................... 58 Pigtail connector

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before

More information

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed 2006-04

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed 2006-04 Circuit Breaker LTB D with Motor Drive Motor Drive ABB PP/H/HV - Page 1 Ed 2006-04 Technology Traditional technology Traditional spring operating mechanism: Closing mechanism ABB PP/H/HV - Page 2 Tripping

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

Current transformers (CT) & Shunts

Current transformers (CT) & Shunts Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar

More information