1 Push Buttons and Operator Interface Specifier s Guide MAGELiS Operator Terminals File 900 CONTENTS Schneider Electric Brands Description Page Product Description XBTH/P/E/HM/PM Display Units and Terminals XBTH Display Units with Line Alphanumeric Screen XBTP Terminals with Line Alphanumeric Screen XBTE Terminals with or 4 Line Alphanumeric Screen XBTHM/PM Display Units with 8 Line Matrix Screen XBTF Terminals with Graphic Screen Development Software Separate Parts XBTF Bus and Network Connections Wiring Diagrams Dimensions Declaration of Conformity

2 Schneider Electric All Rights Reserved /00

3 Product Description General The MAGELiS operator terminals come with the following features: Alphanumeric LCD or fluorescent displays - or 0-inch size Graphical matrix display Monochrome or color screen Touch sensitive types Configuration software based on the Windows programming environment All terminals programmable using the same software package and the same configuration procedure Graphics terminals using a symbols library that allows the programmer to develop customized, animated screens Many different protocols supported that allow communication with a wide variety of programmable controllers NOTE: A bullet ( ) in the catalog number denotes a character that can vary. / Schneider Electric All Rights Reserved 49

4 Product Description Terminals Display Units with Alphanumeric Screen Terminals with Alphanumeric Screen Display Units with Matrix Screen Display Type Fluorescent green matrix ( x 7 pixels), height 0. in. ( mm) or Back-lit LCD ( x 7 pixels), height 0.3 in. (9 mm) Fluorescent green matrix ( x 7 pixels), height 0. in. ( mm) or Back-lit LCD ( x 7 pixels), height 0. in. ( mm) Back-lit monochrome matrix LCD (40 x 4 pixels) height 0. or 0.4 in. (.3 or 0. mm) Capacity lines of 0 characters or 4 lines of 40 characters 4 to 8 lines of 0 to 40 characters Data Entry Display only or Via keypad with 4 function keys or service keys Via keypad with 8 function keys 9 service keys or function keys 0 service keys numeric keys Via keypad with 4 function keys 0 service keys alphanumeric keys Memory Capacity Application 8 KB/ KB Flash EEPROM KB Flash EEPROM 384 KB Flash EEPROM Extension via PCMCIA Type II Functions Maximum Number of Pages Variables per Page 0 Representation of the Variables 00/00 application pages 8/ alarm pages Alphanumeric 400 application pages alarm pages Recipes Curves Alarm Logs Dependent on the model 800 applications pages alarm pages Display only or Via keypad with 4 function keys or service keys 00 application pages alarm pages Alphanumeric, bargraph, gauge Real-Time Clock Access to the PLC real-time clock Built-in Access to the PLC real-time clock Alarm Relay No Yes No Communication Asynchronous Serial Port Downloadable Protocols RS 3 C / RS 48 / RS 4 UNI-TELWAY, MODBUS, AEG and for Allen Bradley, GE Fanuc, Omron, Siemens brand PLCs Buses and Networks AS-i with module at. intervals AS-i with module at. intervals Printer Port Development Software Operating Systems RS 3 C asynchronous serial link (dependent on the model) XBTL000/L003/L004 (under Windows 3. or Windows 9) MAGELiS Type of Terminal XBTH XBTP XBTE XBTHM Page 8 0 XBTL003/L004 (under Windows 9 and Windows NT 4.0) Schneider Electric All Rights Reserved /00

5 Product Description Terminals Display Units with matrix screen Terminals with graphic screen Display Type Capacity Data Entry Back-lit monochrome matrix LCD (40 x 4 pixels) height 0. or 0.4 in. (.3 or 0. mm) 4 to 8 lines of 0 to 40 characters Via keypad with function keys 0 service keys numeric keys 4 dynamic function keys Back-lit monochrome LCD (30 x 40 pixels) or Color LCD STN with touch-sensitive screen (30 x 40 pixels) Back-lit monochrome LCD (40 x 480 pixels) or Back-lit color TFT LCD (40 x 480 pixels).7 in. (4 mm) 9. in. (4 mm) monochrome (XBTF0 only) 0.4 in. (4 mm) color Via touch-sensitive screen with 4 touch-sensitive keys (XBTFC) Touch n Click Via keypad with 0 static function keys 8 dynamic function keys service keys alphanumeric keys Via touch-sensitive screen with 8,, or touch-sensitive keys () (XBTFC) Touch n Click Via keypad with static function keys 0 dynamic function keys service keys alphanumeric keys Memory Capacity Application KB Flash EEPROM 8 MB Flash EEPROM (using Type II PCMCIA card) Extension via PCMCIA Type II Functions Maximum Number of Pages 400 application pages alarm pages printout form pages () 8 MB or MB Variables per Page 0 4 Representation of the Variables Alphanumeric 0 to 40 application, alarm, help, and printout form pages, depending on the memory card used ( alarms max) Alphanumeric, bitmap, bargraph, gauge, potentiometer, selector Recipes Maximum records with maximum 000 values Curves Alarm Logs Dependent on the model Yes Real-time Clock Access to the PLC real-time clock Alarm Relay No Yes Communication Asynchronous Serial Port Downloadable Protocols RS 3 C / RS 48 / RS 4 UNI-TELWAY, MODBUS, AEG and for Allen Bradley, GE Fanuc, Omron, and Siemens brand PLCs Buses and Networks AS-i with module MODBUS Plus, FIPIO /FIPWAY with optional Type III PCMCIA card Printer Port Development Software Operating Systems RS 3 C asynchronous serial link (dependent on the model) XBTL000/L003/L004 MAGELiS XBTL003/L004 (under Windows 9 and NT 4.x) Type of Terminal XBTPM XBTF0/F03/FC XBTF0/F03/FC Page 3 8, 70 8, 70 () Dependent on the model. 30 to 300 application, alarm, help, and printout form pages, depending on memory card used ( alarms max) / Schneider Electric All Rights Reserved

6 Product Description Architectures, connections to control systems MAGELiS operator dialogue terminals communicate with control system equipment: Via serial link Via fieldbus In network architectures Point-to-point or multidrop connection with the PLC via serial link Quantum All terminals incorporate an RS 3 C, RS 4/48 asynchronous serial link as standard. Nano The use of a UNI-TELWAY, MODBUS, or KS protocol means that communication can be set up easily with Schneider Electric PLCs: TSX, MODICON, April, or A-Line. XBT-HM Micro XBT-F MODBUS Third-party protocols provide connection to PLCs offered by the main market suppliers: DF, DH48 for Allen Bradley PLC/SLC00 PLCs SNPX for General Electric Series 90 PLCs Sysway for Omron C00 PLCs AS/394R, MPI/PPI for Siemens Simatic S/S7 PLCs UNI-TELWAY XBT-P Connection to PLCs via fieldbus The addition of a Type III PCMCIA communication card to XBTF terminals with graphic screen enables connection to various industrial networks: FIPIO Bus TBX TBX Premium FIPIO MODBUS Plus XBTF terminals with graphic screen use the bus master PLC to provide operator dialogue and interactive control of various devices connected on the bus. Several terminals with graphic screen can be connected on the same bus. ATV- XBT-F Schneider Electric All Rights Reserved /00

7 Product Description Connection to network architectures The addition of a Type III PCMCIA communication card to XBTF terminals with graphic screen means that they can be integrated into single or multiple network architectures: FIPWAY network MODBUS Plus network XBT-F MODBUS Plus Premium Micro MOMENTUM Quantum FIPIO Bus XBT-F ATV- / Schneider Electric All Rights Reserved 3

8 XBTH/P/E/HM/PM Display Units and Terminals General Presentation XBTH/P/E display units and terminals with alphanumeric screen are used to represent messages and variables. Various keys can be used to modify variables, control the device, or browse in a dialogue application. XBTH XBTP XBTE XBTHM/PM terminals with matrix screen can also be used to display bitmap images and animated bar chart and gauge objects. XBTHM XBTPM Operation All the MAGELiS display units and terminals with alphanumeric and matrix screens have the same user interface: function keys, service keys, and numeric or alphanumeric keys. Configuration MAGELiS display units and terminals can be configured using the same XBTL00 software in a Windows environment. For terminals with an alphanumeric screen, XBTL00 software employs pages. Each page can be viewed in its entirety. Selecting a line of text shows what will appear on the product screen (two to four lines, depending on the model). For XBTHM terminals with a matrix screen, XBTL00 software offers up to 8 lines of 40 characters, and animated bar chart and gauge objects. Communication XBTH/P/E/HM/PM terminals communicate with PLCs via an integrated point-to-point or multidrop serial link. XBTH PLC The communication protocols used are those of Schneider PLCs as well as those of the other main market suppliers. Functions Depending on the model, XBTH/P/E/HM/PM display units and terminals have function keys and service keys on the front panel. Function Keys Function keys are defined for the whole application. They can be used for accessing a page, pulse control, and toggle set/reset. Service Keys Service keys are the arrow keys and the control keys combined. Service keys are used for modifying the parameters of the control system Schneider Electric All Rights Reserved /00

9 The control keys are used to perform the following actions: MAGELiS Operator Terminals XBTH/P/E/HM/PM Display Units and Terminals ENTER MOD ESC SHIFT MENU HOME SYST ALARM PRINT Confirm a selection or entry, acknowledge an alarm Change to the mode for entering pages, passwords, fields or graphic objects Cancel an entry, suspend or stop a current action Access the second of the dual key functions Access a menu containing the operating functions Return to the entry point of the current menu Example: return to the first page of the application Access the confidential mode, which contains the implementation functions View the alarms Print The arrow keys are used to: Change page within a menu Move within a page Select the value of a digit Select a value from a list of choices When used with the SHIFT key, increment or decrement the value of a variable field Description XBTH/P/E/HM/PM display units and terminals include: 4 3 On the front panel:. A communication monitoring indicator lamp. A keypad activity indicator lamp (dependent on the model) 3. Fluorescent or LCD back-lit display 4. Function keys with indicator lamp and reusable labels. Service keys with indicator lamp. Twelve numeric keys (for XBTP0 ) Twelve alphanumeric keys [0 to 9, (+/ ), (.)] associated with three alphabetical access keys (A to Z) for XBTE On the rear:. A plug-in terminal block for 4 Vdc power supply and a connection for the alarm relay (dependent on the model). A female -pin SUB-D connector for connection to PLCs, FTX configuration terminals, or PC compatibles 3. A male 9-pin SUB-D connector for the printer connection (dependent on the model) 3 / Schneider Electric All Rights Reserved

10 XBTH Display Units with Line Alphanumeric Screen Selection XBTH0 00 Display Units with Lines of 0 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log 4 Multilingual XBTH (0.) See page Multilingual XBTH000.3 (0.) 4 Multilingual XBTH000.3 (0.) With Printer Port and Log See page 7 4 Multilingual XBTH00.3 (0.) Display Units with Lines of 0 Characters (LCD) Downloadable Exchange Protocol No Printer Port, No Log UNI-TELWAY See page 7 Function Number of Keys Service Supply Voltage (VDC) 4 and via terminal socket on the TSX Nano/Micro/Premium PLC Language Version Number Multilingual XBTH800.3 (0.) XBTH0 0 XBTH00 00 Display Units with Lines of 0 Characters (Back-Lit LCD) Downloadable Exchange Protocol No Printer Port, No Log See page 7 Function Number of Keys Service Alphanumeric Alphanumeric Alphanumeric Supply Voltage (VDC) Language Version Number 4 Multilingual XBTH (0.) 4 4 Multilingual XBTH000.3 (0.) 4 Multilingual XBTH000.3 (0.) Separate Parts Description Use Number Development Software Under Windows 3. or 9, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in the Product MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Number XBTL003 and XBTL004 XBTX (0.) Schneider Electric All Rights Reserved /00

11 XBTH Display Units with Line Alphanumeric Screen Specifications Type of Display Unit XBTH0 0 (Fluorescent) XBTH800 (LCD) XBTH0 00 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC , EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 40 to +8 F ( 40 to +70 C) 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with 4 or screws (supplied), pressure-mounted on a panel of thickness in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) XBTH00 00 XBTH0 00 Keys No keys 4 function keys service key Electrical Characteristics Display Unit Power Supply XBTH0 0 service keys Fluorescent green matrix characters ( x 7 pixels) lines of 0 characters, height 0. in. ( mm) XBTH800 XBTH00 00 XBTH0 00 service keys No key 4 function keys service key LCD ( x 7 pixels) lines of 0 characters, height 0.3 in. (9 mm) Voltage 4 Vdc not isolated During configuration: 4 Vdc not isolated During operation: Vdc via TSX Nano/Micro/Premium PLC terminal port Voltage Limits 8 30 V Ripple % maximum Consumption 0 W. W 0 W Operating Characteristics Signaling Memory Log Function Transmission (asynchronous serial link) Downloadable Protocol Real-Time Clock Printer Port (asynchronous serial link) XBTH00 00 XBTH0 00 XBTH0 0 XBTH80 Back-lit LCD ( x 7 pixels) lines of 0 characters, height 0.3 in. (9 mm) 4 Vdc not isolated XBTH00 00 XBTH0 00 XBTH0 00 service keys XBTH0 00 LED LEDs 4 LEDs LED LEDs 4 LEDs 8 KB Flash EEPROM, KB (XBTH00) 00 application pages approximately ( lines per page) available alarm pages ( lines per page) Permits storage of alarm pages (XBTH00) 8 KB Flash EEPROM 00 application pages approximately ( lines per page) 8 available alarm pages ( lines per page) 8 KB Flash EEPROM, KB (XBTH000) 00 application pages approximately ( lines per page) available alarm pages ( lines per page) RS 3 C / RS 8 / RS 4 RS 3 C / RS 48 RS 3 C / RS 48 / RS 4 Multiple (see pages 4 and 7) Access to the PLC real-time clock UNI-TELWAY (see pages 4 and 7) Multiple (see page 4 and 7) RS 3 C (XBTH00) Connection Power Supply Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port Female -pin SUB-D connector Printer Port Male 9-pin SUB-D connector / Schneider Electric All Rights Reserved 7

12 XBTP Terminals with Line Alphanumeric Screen Selection XBTP0 00 Terminals with Lines of 0 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log Multilingual XBTP000.8 (0.8) See page Multilingual XBTP000.8 (0.8) With Printer Port and Log See page Multilingual XBTP00.8 (0.8) XBTP0 0 Terminals with Lines of 0 Characters (Back-Lit LCD) Downloadable Exchange Protocol Function Number of Keys Service Alphanumeric Alphanumeric Supply Voltage (VDC) Language Version Number No Printer Port, No Log Multilingual XBTP000.8 (0.8) See page Multilingual XBTP000.8 (0.8) With Printer Port and Log See page Multilingual XBTP00.8 (0.8) Separate Parts Description Use Number Development Software Under Windows 3. or 9, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in the Product MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Number XBTL003 and XBTL004 XBTX (0.) Schneider Electric All Rights Reserved /00

13 XBTP Terminals with Line Alphanumeric Screen Specifications Type of Terminal XBTP0 0 (Fluorescent) XBTP0 0 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC , EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 40 to +8 F ( 40 to +70 C) 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 009, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with 4 or screws (supplied), pressure-mounted on a panel of thickness in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) XBTP000 XBTP0 0 XBTP000 XBTP0 0 Keys Electrical Characteristics Display Unit Power Voltage Supply Voltage Limits Ripple Consumption Operating Characteristics Signaling Memory 8 function keys 9 service keys function keys 0 service keys numeric keys Fluorescent green matrix characters ( x 7 pixels) lines of 0 characters, height 0.0 in. ( mm) 4 Vdc not isolated 8 30 V % maximum 0 W 8 function keys 9 service keys function keys 0 service keys numeric keys Back-lit LCD ( x 7 pixels) lines of 0 characters, height 0.3 in. (9 mm) XBTP000 XBTP0 0 XBTP000 XBTP0 0 7 LEDs LEDs 7 LEDs LEDs KB Flash EEPROM 400 application pages approximately ( lines per page) available alarm pages ( lines per page) Log Function Permits storage of alarm pages (XBTP00) Permits storage of alarm pages (XBTP00) Transmission (asynchronous serial link) RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) Real-Time Clock Printer Port (asynchronous serial link) Access to the PLC real-time clock RS 3 C (XBTP00) Connection Power Supply Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port Female -pin SUB-D connector Printer Port Male 9-pin SUB-D connector RS 3 C (XBTP00) / Schneider Electric All Rights Reserved 9

14 XBTE Terminals with or 4 Line Alphanumeric Screen Selection Terminals with Lines of 40 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page Multilingual XBTE0400. (.0) With Printer Port and Log See page Multilingual XBTE040. (.0) XBTE04 0 Terminals with 4 Lines of 40 Characters (Fluorescent) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page Multilingual XBTE000. (.0) With Printer Port and Log See page Multilingual XBTE00. (.0) XBTE0 0 Terminals with Lines of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol Function Number of Keys Service Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page Multilingual XBTE0300. (.0) With Printer Port and Log See page Multilingual XBTE030. (.0) XBTE03 0 Terminals with 4 Lines of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol Function Number of Keys Service Alphanumeric Alphanumeric Alphanumeric Alphanumeric Supply Voltage (VDC) Language Version Number No Printer Port, No Log See page Multilingual XBTE000. (.0) With Printer Port and Log See page Multilingual XBTE00. (.0) XBTE0 0 Separate Parts Description Use Number Development Software Under Windows 3. or 9, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in Product MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Number XBTL003 and XBTL004 XBTX (0.) Schneider Electric All Rights Reserved /00

15 XBTE Terminals with or 4 Line Alphanumeric Screen Specifications Type of Terminal XBTE04 0/XBTE0 0 (Fluorescent) XBTE03 0/XBTE0 0 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC , EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 40 to +8 F ( 40 to +70 C) 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with 4 or screws (supplied), pressure-mounted on a panel of thickness in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Keys Function 4 Service 0 Alphanumeric Electrical Characteristics Display Unit Fluorescent green matrix characters ( x 7 pixels) Back-lit LCD ( x 7 pixels) XBTE04 0 XBTE0 0 XBTE03 0 XBTE0 0 lines of 40 characters, height 0.0 in. ( mm) 4 lines of 40 characters, height 0.0 in. ( mm) Power Voltage 4 Vdc not isolated Supply Voltage Limits 8 30 V Ripple % maximum Consumption 0 W 0 W Operating Characteristics Signaling 33 LEDs + buzzer Memory 384 KB Flash EEPROM 800 application pages approximately ( lines per page) available alarm pages ( lines per page) 400 application pages approximately (4 lines per page) 8 available alarm pages (4 lines per page) Log Function Transmission (asynchronous serial link) Permits storage of alarm pages RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) lines of 40 characters, height 0.0 in. ( mm) 4 lines of 40 characters, height 0.0 in. ( mm) Real-Time Clock Printer Port (asynchronous serial link) Alarm Relay Connection Power Supply and Alarm Relay Serial Port Printer Port Access to the PLC real-time clock RS 3 C (XBTE040 and XBTE00) N.O. contact min. ma/ Vdc max. 0. A/4 Vdc Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Female -pin SUB-D connector Male 9-pin SUB-D connector RS 3 C (XBTE030 and XBTE00) / Schneider Electric All Rights Reserved

16 XBTHM/PM Display Units with 8 Line Matrix Screen Selection XBTHM00700 XBTHM0700 Display Units with 8 Line Matrix Screen of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol See page 7 Function Number of Keys Service Alphanumeric Supply Voltage (VDC) Language Version Number 4 Multilingual XBTHM (0.) No Printer Port, No Log 4 4 Multilingual XBTHM (0.) 4 Multilingual XBTHM (0.) Power Suite 4 Multilingual XBTHM0700A8.3 (0.) With Printer Port and Log 4 Multilingual XBTHM070.3 (0.) Terminal specifically for controlling up to eight ATV8/ATV8 variable-speed drive controllers. Separate Parts Description Use Number Development Software Under Windows 9 or NT 4.0, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in Product Number MAGELiS User s Manual A Bound (48 x 0 mm, approx. x 8. in) XBTL003 and XBTL004 XBTX (0.) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. XBTHM07 0 Specifications Type of Display Unit XBTHM0 7 0 (Back-Lit LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC , EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to + F (0 to +0 C) Storage 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with spring clips (supplied), pressure-mounted on a panel of thickness in. ( mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) XBTHM00700 XBTHM0700 XBTHM07 0 Keys No keys 4 function keys + service key service keys Electrical Characteristics Display Unit Back-lit LCD (40 x 4 pixels) 8 lines of 40 character, height 0. in. (.3 mm), single size 4 lines of 0 characters height 0.4 in. (0. mm), double height, double width Power Supply Voltage 4 Vdc not isolated Voltage Limits 8 30 V Ripple % maximum Consumption W Operating Characteristics XBTHM00700 XBTHM0700 XBTHM07 0 Signaling LED LEDs 4 LEDs Memory 384 KB Flash EEPROM 00 application pages approximately (8 lines per page), available alarm pages ( lines per page) Transmission (asynchronous serial link) RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) Real-Time Clock Access to the PLC real-time clock Printer Port (asynchronous serial link) RS 3 C (XBTHM070) Connection Power Supply Plug-in terminal block 3 screw terminals, 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port Female -pin SUB-D connector Printer Port Male 9-pin SUB-D connector Schneider Electric All Rights Reserved /00

17 XBTHM/PM Display Units with 8 Line Matrix Screen Selection XBTPM Terminals with 8 Line Matrix Screen of 40 Characters (Back-Lit LCD) Downloadable Exchange Protocol No Printer Port See page 7 Function Number of Keys Dynamic Function Service Alphanumeric Supply Voltage (VDC) Language Version Number Multilingual XBTPM (0.) With Printer Port See page Multilingual XBTPM070.3 (0.) Separate Parts Description Use Number Development Software Under Windows 9 or NT 4.0, for downloading the application and protocols See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Documentation Description Format Included in the Product Number MAGELiS User's Manual A Bound (48 x 0 mm, approx. x 8. in) XBTL003 and XBTL004 XBTX (0.) Add the following suffixes EN: English, FR: French, DE: German, ES: Spanish, T: Italian. Specifications Type of Display Unit XBTPM07 0 (Back-lit matrix LCD) Environment Conforming to Standards IEC 3-, IEC 008--, IEC , EN 3-, UL 08, CSA C- No. 4 Product Certifications CE, UL, CSA, UL E48; CCN: NRAQ, CSA LR 44087; Class 0, UL FM Class Division Temperature Operation +3 to + F (0 to +0 C) Storage 4 to +40 F ( 0 to +0 C) Degree of Protection IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with spring clips (supplied), pressure-mounted on a panel of thickness in. (. mm) Material Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Keys Function static, 4 dynamic Service Numeric Electrical Characteristics Display Unit Back-lit LCD (40 x 4 pixels) 8 lines of 40 characters, height 0. in. (.3 mm), single size 4 lines of 0 characters, height 0.4 in. (0. mm), double height, double width Power Supply Voltage 4 Vdc, not isolated Voltage Limits 8 30 V Ripple % maximum Consumption W Operating Characteristics Signaling LEDs Memory KB Flash EEPROM 400 application pages approximately available alarm pages depending on distribution Transmission (asynchronous serial link) RS 3 C / RS 48 / RS 4 Downloadable Protocol Multiple (see pages 4 and 7) Real-Time Clock Access to the PLC real-time clock Printer Port (asynchronous serial link) RS 3 C (XBTPM070) Connection Power Supply Plug-in terminal block 3 screw terminals 3/4 (.08 mm) pitch Maximum clamping capacity: # AWG (. mm ) Serial Port -pin SUB-D connector Printer Port 9-pin SUB-D connector / Schneider Electric All Rights Reserved 3

18 XBTF Terminals with Graphic Screen General Presentation Graphic screen operator dialogue terminals are available with or 0 in. (7 or 4 mm) screens, in monochrome or color, with a keypad or a touchsensitive screen. XBTF graphic screen terminals are specially designed for operator dialogue graphic functions. XBTF0/F03 XBTF0/F03 XBTFC0/F04 XBTFC0/F08 Operation All MAGELiS graphic screen terminals have the same user interface: static and dynamic function keys, service keys, alphanumeric keys. Configuration MAGELiS graphic screen terminals can be configured using the same XBTL00 software in a Windows environment. XBTL00 software provides graphic screen terminals with a library of animated graphic objects such as bargraphs, volume indicator meters, selectors, potentiometers, and trending curves. The variable for animating an object can be selected directly from a list of symbols given by the PL7 or CONCEPT TM software. The application program for the graphic terminals is stored on a PCMCIA memory card. Communication XBTF PLC XBTF graphic screen terminals communicate with PLCs via an integrated point-to-point or multidrop serial link, or via a field bus with a PCMCIA Type III card. The communication protocols are those used by Schneider Electric PLCs as well as those of the other main market suppliers. PLC Schneider Electric All Rights Reserved /00

19 XBTF Terminals with Graphic Screen Functions XBTF graphic screen operator dialogue terminals have the following functions: Displaying animated synoptic screens, control, modification of numeric and alphanumeric variables Displaying a service line (status and alarm bar) with the current time Dynamic visualization of operating data (setpoints, measurements, recipes, maintenance messages) and process errors Control via dynamic or static function keys Scaling analog variables Real-time and trending curves Alarm log and managing alarm groups Managing help pages, form pages, recipe pages Pages called by the user or by the PLC Three levels of passwords Printing form pages, date-stamped log and alarms Communication protocol application support in the PCMCIA Type II application memory card The role of the function keys is defined using the XBTL00 software. Modifications cannot be made during operation. Each function key can be associated with an internal bit of the PLC application. Static Function Keys (F ) Static function keys are defined for the whole application. They perform the following actions: Accessing a page Pulse control Toggle set/reset control Static keys can be marked with reusable labels. Dynamic function keys and touch-sensitive keys Dynamic function keys and touch-sensitive keys are associated with a page. Their role can therefore differ from one page to another. They perform the following actions: Accessing a page Latching memory bits Toggling memory bits (on/off) Accessing the modification of a value Direct writing Each dynamic key and touch-sensitive key can be assigned a label or icon illustrating its function. On touch-sensitive terminals, the touch-sensitive zones function in a similar way to the dynamic keys on keypad terminals. / Schneider Electric All Rights Reserved

20 XBTF Terminals with Graphic Screen Service Keys Service keys are the arrow keys and the control keys combined. Service keys are used to modify the parameters of the control system. The control keys perform the following actions: ENTER MOD ESC SHIFT MENU HOME SYST ALARM PRINT Confirm a selection or entry, acknowledge an alarm Change to the mode for entering pages, passwords, fields, or graphic objects Cancel an entry, suspend or stop a current action; display previous pages in succession; quit the alarm display Access the second of the dual key functions Access a menu containing the operating functions that do not have direct access keys Return to the entry point of the current menu Example: return to the first page of the application Access the confidential mode that contains the passwordprotected implementation functions View the alarms Print The arrow keys perform the following actions: Change the page within a menu Change fields on a page Select an object on a page Move within a page Select the value of a digit Select a value from a list of choices When used with the SHIFT key, increment or decrement the value of a variable field Schneider Electric All Rights Reserved /00

21 XBTF Terminals with Graphic Screen XBTF0/F0 Description The front panel of XBTF0/F0 keypad terminals includes: 3 4. A monochrome or color screen.7, 9., or 0.4 in. (4, 4, or 4 mm) depending on the model. x 4 or x dynamic function keys (depending on the model) with indicator lights 3. A communication monitoring indicator light 4. A keypad activity indicator light. x or x static function keys (depending on the model) with indicator lights and re-usable labels. Twelve service keys with indicator lights 7. Twelve alphanumeric keys [0 to 9, (+/ ), (.)] associated with three alphabetical access keys (A to Z) 7 The front panel of XBTF03 touch-sensitive screen terminals includes: 3. A touch-sensitive color screen.7 or 0.4 in. (4 or 4 mm) depending on the model. A communication monitoring indicator light 3. A tactile feedback activity indicator light The front panel of XBTFC touch-sensitive screen terminals includes: 3 4. A touch-sensitive color screen.7 or 0.4 in. (4 or 4 mm) depending on the model. A communication monitoring indicator light 3. A tactile feedback activity indicator light 4. An alarm indicator light. 4, 8,, or touch-sensitive keys (depending on the Touch n Click model) / Schneider Electric All Rights Reserved 7

22 XBTF Terminals with Graphic Screen Selection Terminals with Keypads Downloadable Exchange Protocol Type and Size of Screen Supply Voltage (VDC) Type III Slot for PCMCIA Communication Card Number Monochrome.7 in. (4 mm) 4 No XBTF (.8) Yes XBTF (.8) See page 7 Monochrome 9. in. (4 mm) 4 No XBTF030.0 (.7) Yes XBTF (.7) XBTF04 0 Color 0.4 in. (4 mm) 4 No XBTF040.0 (.7) Yes XBTF (.7) XBTF034 0 Terminals with Touch-Sensitive Screens Downloadable Exchange Protocol See page 7 Type and Size of Screen Color.7 in. (4 mm) Color 0.4 in. (4 mm) Supply Voltage (VDC) 4 4 Type III Slot for PCMCIA Communication Card Number No XBTF (.) Yes XBTF (.) No XBTF (.4) Yes XBTF (.4) Separate Parts Description Use Number Development Software Under Windows 9 or NT 4.0, for downloading the application and protocols See page 7 PCMCIA Type II Memory Cards Application memory See page 7 PCMCIA Type III Memory Cards Bus and industrial networks connection See page 7 Connecting Cables Connection to PLCs, configuration terminals, etc. See page 7 Sheet of Labels Labels for function keys See page 7 XBTMEM08 Replacement Parts Description Use Memory PCMCIA Type II Memory Card PCMCIA Type II Memory Card Number XBTF terminals 8 MB XBTMEM08 0. (0.) XBTF terminals MB XBTMEM 0. (0.) Schneider Electric All Rights Reserved /00

23 XBTF Terminals with Graphic Screen Specifications Type of Terminal XBTF0 XBTF03 XBTF03/F04 XBTF034 Environment Conforming to Standards IEC 3-, IEC 080- level 3, IEC and IEC level 3, IEC 008--, IEC , UL 08, CSA C. No. 4 Product Certifications CE, UL, CSA, UL E48, CCN: NRAQ, CSA LR 44087, Class 0 Temperature Operation +3 to +3 F (0 to +4 C) Storage 4 to +40 F ( 0 to +0 C) Degree of Front Panel IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Protection Rear Panel IP 0, conforming to IEC 09 Mechanical Characteristics Mounting and Fixing Flush-mounted, fixed with spring clips (supplied), pressure-mounted on a panel of thickness in. (. mm) 0 spring clips 8 spring clips spring clips 0 spring clips Material Front Section Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Enclosure Polyphenyl oxide, 0% glass fiber (PPO GFN SE) Keys Dynamic Keys 8 (with LED) 0 (with LED) Static Keys 0 (with LED and re-usable labels) (with LED and re-usable labels) Service Keys Alphanumeric Keys Electrical Characteristics, plus 3 for alphabetical access LED Screen Type.7 in. (4 mm) monochrome, back-lit with levels of grey.7 in. (4 mm) STN colors, back-lit with resistive matrix tactile feedback, plus 3 for alphabetical access XBTF03: 9. in. (4 mm) monochrome, back-lit with levels of grey XBTF04: 0.4 in. (4 mm) TFT colors Resolution 30 x 40 pixels 40 x 480 pixels 0.4 in. (4 mm) TFT colors with resistive matrix tactile feedback Power Supply Voltage 4 Vdc not isolated Voltage Limits 8 30 V, maximum ripple %, maximum microbreaks ms Protection Against polarity inversion and overloads Consumption 3 W Operating Characteristics Signaling LED for communication monitoring, LED for keypad activity (or tactile feedback activity), and LEDs associated with service and alphanumeric keys Operating System Dynamic RAM Memory Application Memory Dialogue Application Max. number of pages MAGELiS. MB On 8 MB PCMCIA Type II card (supplied), 8, MB 0 40 application, alarm, help, form, and recipe pages depending on the memory card used Curves real-time curves real-time curves Real-Time Clock Access to the PLC real-time clock Alarm Relay One volt-free N.O. contact, max. 0. A, 4 Vdc/Vac Connection Power Supply Plug-in terminal, screw terminals, 3/4 (.08 mm) pitch and Maximum clamping capacity: # AWG (. mm Alarm Relay ) PLC Female -pin SUB-D connector Printer/ Configuration Male 9-pin SUB-D connector PC application, alarm, help, form, and recipe pages depending on the memory card used / Schneider Electric All Rights Reserved 9

24 XBTF Terminals with Graphic Screen Touch n Click Terminals Terminals with touch-sensitive screens XBTFC030 Downloadable Exchange Protocol Type and Size of Screen Supply voltage (VDC) Number of touchsensitive keys Number lb (kg) Color.7 in. (4 mm) 4 4 XBTFC (.) See page 7 Color 0.4 in. (4 mm) 4 8 XBTFC (.4) XBTFC (.4) XBTFC (.4) XBTFC04430 Separate parts XBTFC08430 Description Use Number Development Software Under Windows 9 or NT 4.x, for downloading the application and protocols See page 7 Type II PCMCIA Memory Cards Application memory See page 7 Type III PCMCIA Communication Cards Connection to buses and industrial networks See page 7 Connecting Cables Serial link, UNI-TELWAY bus, configuration terminal, printer connection lb (kg) See page 7 Replacement part XBTFC0430 Description Use Memory size Number lb (kg) Type II PCMCIA Memory Card XBTFC terminals 8 MB XBTMEM08 0. (0.) Type II PCMCIA Memory Card XBTFC terminals MB XBTMEM 0. (0.) XBTMEM Schneider Electric All Rights Reserved /00

25 XBTFC Touch n Click Terminals MAGELiS terminals with graphic screen Characteristics Type of terminal XBTFC030 XBTFC04430 XBTFC08430 XBTFC0430 Environment IEC 3-, IEC level 3, IEC and IEC level 3, IEC 008--, Conforming to Standards IEC , UL 08, CSA C. No. 4 Approvals CE, UL, CSA Temperature Relative humidity Operation Storage +3 to +3 F (0 to +4 C) 4 to +40 F ( 0 to +0 C) 0 8% (without condensation) Degree of Front panel IP, conforming to IEC 09, NEMA Type 4, UL Type 4 Protection Back panel IP 0, conforming to IEC 09 Shock Resistance Conforming to IEC ; semi-sinusoidal pulse ms, g in the 3 axes Vibrations Conforming to IEC 008--; 0 7 Hz at 0.07 mm (0.003 in.); 7 0 Hz g for 3 hours per axis Electrostatic Discharge Conforming to IEC , level 3 Electromagnetic Interference Conforming to IEC , 0 V/m Electrical Interference Conforming to IEC , level 3 Mechanical Characteristics Flush-mounted, fixed with spring clips (supplied), Mounting and Fixing pressure-mounted on a panel of thickness in. (. mm) 8 spring clips 0 spring clips Screen protection. mm (0.0 in.) polyester mm (0.08 in.) polyester Material Front frame Polyphenyl oxide, 0% glass fibre (PPO GFN SE ) Keypad Anti-UV treated toughened polyester (Autoflex EB AG) Enclosure Polyphenyl oxide, 0% glass fibre (PPO GFN SE ) Touch-Sensitive Keys 4 in one row 8 in one row in two rows in two columns Electrical Characteristics.7 in. (4 mm) STN colors back-lit with resistive matrix tactile feedback (8 x 4 cells) 0.4 in. (4 mm) TFT colors with resistive matrix tactile feedback XBTFC04 has 3 x 8 cells, XBTFC0 has 9 x 0 cells, XBTFC 08 has 3 x cells Type LCD Screen Definition 30 x 40 pixels 40 x 480 pixels Voltage 4 Vdc not isolated Power Supply Limits 8 30 V, including % maximum ripple, microbreaks ms maximum Protection Against polarity inversion and overloads Consumption 3 W Operating characteristics Signaling communication monitoring LED, keypad activity LED and alarm LEDs Operating System MAGELiS Dynamic RAM Memory. MB Application Memory On Type II PCMCIA card: 8 MB (supplied) or MB Dialogue Application Maximum no. of pages 0 40 application, alarm, help, form, and recipe pages depending on the memory card used ( alarm and form max.) application, alarm, help, form, and recipe pages depending on the memory card used ( alarm and form max.) Curves real-time curves Recipes Maximum 000 parameter values in a maximum of recipe records PLC/ Configuration PC RS 3 C / RS 4 / RS 48 isolated serial link, downloadable communication protocols (see pages and 3) Communication Printer RS 3 C serial link Bus or network Slot for Type III PCMCIA communication card, communication protocols (see page 3) Real-Time Clock Access to the PLC real-time clock Alarm Relay volt-free N.O. contact, max 0. A, 4 Vdc/Vac Connection Power supply and alarm relay PLC Printer/ Configuration PC Plug-in terminal block, screw terminals at intervals of 3/4 (.08 mm) Max clamping capacity: # AWG (. mm ) -pin female SUB-D connector 9-pin male SUB-D connector / Schneider Electric All Rights Reserved 7

26 Development Software XBTL003/L004 Software Functions Simulation on PC compatible XBTL003/L004 software offers the option of simulating all the operator dialogue applications from the design office without the use of graphic terminals and PLCs. The following can be tested using the simulation program and the keyboard on a PC compatible: Navigating between pages Entering variables Displaying variables Simulating an alarm Using the function keys The operator terminals and graphic stations have two types of function keys: static and dynamic.. Static keys These are defined for the whole application. They may have the following functions: Access a page Pulse a PLC memory bit Latch a PLC memory bit. Dynamic keys These are associated with one page. Their role can be reassigned or changed from one page to another. They may have the following functions: Access a page Pulse a PLC memory bit Latch a PLC memory bit Position on a data entry field A label (bitmap image) is assigned to each key, which may vary from page to page Schneider Electric All Rights Reserved /00

27 Development Software XBTL003/004 Software XBTL003/L004 development software is used with the whole range of MAGELiS terminals to create operator dialogue applications designed for controlling automated systems. XBTL003/L004 software runs on PC compatibles equipped with Windows 9 or NT 4.0 operating software. Applications created using XBTL003/L004 software are independent of the protocol used; it is possible to use the same operator dialogue application with all the different PLCs offered by the main market suppliers. Configuration XBTL003/L004 software is the only configuration software package for the MAGELiS range. It runs under Windows 9 or NT 4.0. It is used to create various types of pages easily: Application pages (can be interlinked) Alarm pages Help pages Recipe pages Form pages The pages can contain all sorts of variables and graphic objects, which are either predefined in the XBTL003/L004 software or created using other applications and then imported (bitmap format, etc.). Various properties can be assigned to them: min-max limits, color, movement, weighting, etc. XBTL003/L004 software can be used to configure the function keys to activate commands on the machine or call application pages. It can also be used on the graphic terminals to import the PL7 or CONCEPT PLC symbols database. Main toolbar Midday Bakery Bread Recipe Flour Soda Water Select the quantities of each product Page Information window Use the? button for more information Graphic toolbar Page Tree Structure window The XBTL000 software package is designed for DOS.0 (minimum) with the Windows 3. operating system. Hardware requirements are a minimum of a 38 processor operating at MHz, with 8 MB RAM and 0 MB free hard disk space. / Schneider Electric All Rights Reserved 73

28 Development Software Screen windows XBTL003/L004 software is used to design page contents in WYSIWYG (what you see is what you get): anything created using the software is displayed in exactly the same way on the operator dialogue terminal screen. To assist the designer, the software offers a display unit or a virtual screen depending on the type of terminal. XBTHP XBTE XBTHM XBTF Model pages Midday Bakery Model pages, created by the designer, are pages whose graphic format (text, images, or static objects) applies to all other pages in the same family. There are three types of model pages: Application Alarm Help Model pages are available with XBTF graphic terminals. Alarm pages Alarm pages indicate any faults in the process. The advantage of alarm pages lies in their event-triggered display: During operation When a fault occurs, it is often the consequence of other faults. The priority levels enable the terminal to display the most important fault: the one presenting the highest risk to the process. The occurrence of any fault is time and date stamped. During maintenance operations The terminal memorizes the faults in sequence (log) making it easy to find the cause of the fault. Help pages and help windows Help pages and windows can be associated with application or alarm pages. Help windows can be associated with any variable field Schneider Electric All Rights Reserved /00

29 Development Software Software for MAGELiS Terminals Multilingual software packages are designed for FTX 7 terminals or PC compatibles (minimum requirements: 48 processor, MHz, 30 MB free space on the hard disk and either 8 MB RAM memory with a Windows 9 operating system or MB RAM memory with an NT 4.0 operating system). They include the following communication protocols: UNI-TELWAY, FIPIO, FIPWAY, MODBUS, Jbus, MODBUS Plus, KS. Schneider Pack Software (with Schneider Electric Protocols) Description Compatibility Operating System Support Documentation for alphanumeric and graphic terminals Number XBTL003 French XBTL003F 3.3 (.) Alphanumeric and graphic configuration XBTH/P/E/HM/PM XBTF Windows 9, 98, 000, or NT 4.0 CD-ROM English XBTL003E 3.3 (.) German XBTL003G 3.3 (.) Spanish XBTL003S 3.3 (.) Italian XBTL003T 3.3 (.) Note: Packages contain the XBTZ9 cable and -pin/9-pin connection interface XBTZ9. Open Pack Software (with Schneider Electric and Third Party Protocols) XBTL004 Description Alphanumeric and graphic configuration Compatibility XBTH/P/E/HM/PM XBTF Operating System Windows 9, 98, 000, or NT 4.0 Support CD-ROM Note: Packages contain the XBTZ9 cable and -pin/9-pin connection interface XBTZ9. Documentation Number French XBTL004F 4.4 (.0) English XBTL004E 4.4 (.0) German XBTL004G 4.4 (.0) Spanish XBTL004S 4.4 (.0) Italian XBTL004T 4.4 (.0) Schneider Update Pack with Schneider Electric Protocols Description Compatibility Operating System Support Documentation Number Alphanumeric and graphic configuration XBTH/P/E/HM/PM XBTF/XBTFC Windows 9, 98, 000, or NT 4.0 CD-ROM Five-language PDF format XBTLUP003. (0.) Schneider Pack Software with Schneider Electric Protocols (Light Pack) Description Compatibility Operating System Support Documentation Number Alphanumeric configuration XBTH/P/E Windows 3. or Windows 9 Diskette Ordered separately XBTL000. (0.) Diagnostic Viewer/Remote Network Transfer Option Description Alphanumeric and graphic configuration Compatibility XBTH/P/E/HM/PM XBTF/XBTFC Operating System Windows 9, 98, 000, or NT 4.0 Diagnostics with PL7PRO on TSX7 Premium. Remote transfer over MODBUS Plus or FIPWAY. Dynamic database link from PL7PRO or CONCEPT to XBTL000 Support Documentation Number CD-ROM None TXBTLDIAGCDM. (0.) For a list of Schneider Electric and third party protocols, refer to page 7. / Schneider Electric All Rights Reserved 7

30 Separate Parts Downloadable protocols (onto diskettes) PLC Brands Compatibility Name of Protocol Number Schneider Electric Allen Bradley XBTH/P/E (only for XBTL000 software) XBTH/P/E/HM XBTF lb (kg) UNI-TELWAY V.0 UNI-TELWAY V.0 XBTLUTW0.43 (0.) MODBUS Jbus XBTLMOD0.43 (0.) KS XBTLAEG0.43 (0.) DF DH48 XBTLAB0.43 (0.) GE Fanuc XBTH/P/E SNPX XBTLGE0.43 (0.) Omron Siemens XBTH/P/E/HM XBTF Sysmacway XBTLOMR0.43 (0.) XBTH/P/E/HM AS 394R XBTLSIE0.43 (0.) XBTF PPI, MPI XBTLSIE0.43 (0.) Communication on buses and networks Type of Protocol Compatibility Support Number lb (kg) AS-i XBTH/P/HM Module at. intervals XBTZA (0.30) MODBUS Plus XBTF Type III PCMCIA TSXMBP00.43 (0.) FIPIO XBTF Type III PCMCIA TSXFPP0.43 (0.) FIPWAY FIPWAY on XBTF Type III PCMCIA TSXFPP0.43 (0.) Type II PCMCIA memory cards XBTMEM08 Size Compatibility Approximate Number of Pages Number XBTF0/F03/FC0 XBTF0/F034/FC04 lb (kg) 8 MB XBTF XBTMEM08 0. (0.0) MB XBTF XBTMEM 0. (0.0) Note: The XBTF terminal comes with an 8 MB PCMCIA card. Accessories Type Sold in Lots of Compatibility Number Sheets of re-usable labels XBTH0 00 XBTP0 00 XBTP0 0 XBTE XBTHM XBTF0 XBTF0 XBLYH4 XBLYP8 XBLYP XBLYE4 XBLYHM4 XBLYF0 XBLYF lb (kg) 0. (0.0) Desk holder XBTF XBTZ (0.0) XBTHM/F XBTZ (0.0) Spring clips 0 XBTH/P/E XBTZ (0.0) Power supply connector 0 XBT XBTZ (0.0) Connection to PCs and printers Use Connection Compatibility Number lb (kg) RS3C PC link (. m) 9-pin (male) Any XBT XBTZ (0.0) Between XBTZ9 cable and XBTF terminal 9-pin/-pin XBTF XBTZ9 0. (0.0) Serial printer with printer port 9-pin/-pin Any XBT XBTZ (0.0) Schneider Electric All Rights Reserved /00

Display units With alphanumeric screen

Display units With alphanumeric screen Display units With alphanumeric screen Compact display units Display Capacity lines, 0 characters 4 lines, 0 characters Back-lit LCD, green Back-lit LCD, green Back-lit LCD, 3 colours: green, orange, red

More information

Operator dialogue terminals

Operator dialogue terminals Magelis text displays and operator terminals Characteristics : page /43 References : pages /44 to /46 General Design of the XBT-H/P/E range of display units and terminals Range XBT-H XBT-P XBT/H/P/E display

More information

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM. 6AV3617-1JC30-0AX1 Page 1 Product data sheet 6AV3617-1JC30-0AX1 OPERATOR PANEL OP17/DP12 LC DISPLAY, BACKLIT LED 4X20/8X40 LINESXCHARACTERS SIMATIC S5, 505, S7, M7, NATIVE DRIVERS, PROFIBUS-DP 12 MBAUD,

More information

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5 - TFT - 96 MB Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis

More information

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12 6AV3017-1NE30-0AX0 Page 1 Product data sheet 6AV3017-1NE30-0AX0 TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12 Supply voltage

More information

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

EA7-T8C EA7-T10C EA7-T12C EA7-T15C The new Generation of Touch Panels with ambitious image presentation and integrated operating function With the C-more series, featuring STN and TFT touch screens, AutomationDirect now provides the best

More information

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED 6AV3607-1JC20-0AX1 Page 1 Product data sheet 6AV3607-1JC20-0AX1 OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED Supply voltage

More information

MI4 - Operator Panel : Engineering

MI4 - Operator Panel : Engineering MI4 - Operator Panel : Engineering MI4 - Operator Panel : Engineering Overview MI4 Text Operator Panel MI4 Graphic Operator Panel MI4 Touch Operator Panel Communication modules Accessories MI4-CFG-1 Engineering

More information

Pop. Parker operator panels. Pop CANopen. Compax3 I21T11 CANopen. with integrated axis. standalone SMH/MH. CANopen. digital inputs & outputs

Pop. Parker operator panels. Pop CANopen. Compax3 I21T11 CANopen. with integrated axis. standalone SMH/MH. CANopen. digital inputs & outputs Pop Compax3 powerplmc C1x with integrated axis Compax3 I21T11 powerplmc-e20 standalone SMH/MH digital inputs & outputs servo motors PIO I/O Pop Parker operator panels 2 3 Automation Control and Monitoring

More information

UniOP epad33 and epad33t

UniOP epad33 and epad33t UniOP epad33 and epad33t The epad33 and epad33t are state-of-the-art HMI devices with a 10.4 graphic display and a complete keypad. The aluminum bezel offers an appealing look in a rugged and convenient

More information

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4

Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4 Modicon Premium PLCs TSX 57/PCX 57 Communication Network and Bus Interfaces Installation manual Volume 4 eng May 2007 35009581_02 2 335009581 02 May 2007 Document Set Document Set At a Glance This documentation

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Pop Parker Operator Panels. Catalog: 192-081011 N1 / GB Version 1, December 2001

Pop Parker Operator Panels. Catalog: 192-081011 N1 / GB Version 1, December 2001 Pop Parker Operator Panels Catalog: 192-081011 N1 / GB Version 1, December 2001 192-081011 N1 192-081011N1 Automation Operation and Observation Parker Operator Panels Parker provides operator panels for

More information

ALARM SYSTEM PLC. MODICON 984 - A120 Description. 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN

ALARM SYSTEM PLC. MODICON 984 - A120 Description. 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN ALARM SYSTEM PLC MODICON 984 - A120 Description 01 September 2000 ASI GmbH B. Dittmer LADESTRASSE 3-3A 28197 BREMEN Alarm System PLC 984 - A120, Sheet 2 1. Compact Hardware The Alarm- and Monitoring System,

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Operator Control and Monitoring Devices

Operator Control and Monitoring Devices Operator Control and Monitoring Devices Siemens AG 008 Overview Benefits Integral component of Totally Integrated Automation (TIA): Increased productivity, minimum engineering overhead, reduction in life-cycle

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Magelis XBT N/R/RT 33003962 11/2011. Magelis XBT N/R/RT. Compact Display Units User Manual 11/2011 33003962.03. www.schneider-electric.

Magelis XBT N/R/RT 33003962 11/2011. Magelis XBT N/R/RT. Compact Display Units User Manual 11/2011 33003962.03. www.schneider-electric. Magelis XBT N/R/RT 33003962 11/2011 Magelis XBT N/R/RT Compact Display Units User Manual 11/2011 33003962.03 www.schneider-electric.com The information provided in this documentation contains general descriptions

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue E L E K T R O N I K Appliance description Human Maschine Interfaces - HMI wide range of products in text and touch screen design direct connectable to FPSC and AKAS systems integrated PLC funktionality

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

Solid as a Rock etop 300/400

Solid as a Rock etop 300/400 Solid as a Rock etop 300/400 5 years warranty E X O R I N T E R N A T I O N A L Product Presentation etop 300/400 At a glance Five years warranty Products available with a choice of two operating systems

More information

Repeaters and Mimics Data Sheet

Repeaters and Mimics Data Sheet Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.

More information

Concentrating on the essentials: the new Basic Panels SIMATIC HMI. Answers for industry.

Concentrating on the essentials: the new Basic Panels SIMATIC HMI. Answers for industry. Concentrating on the essentials: the new Basic Panels SIMATIC HMI Answers for industry. Number 1 in operator control and monitoring From simple operator keypads and mobile devices to flexible Multi Panels:

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Tracer Summit Web Server

Tracer Summit Web Server Tracer Summit Web Server Web-based access for the Tracer Summit building automation system March 2003 BAS-PRC014-EN Introduction The Tracer Summit Web Server provides the ability to operate a Tracer Summit

More information

Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301

Product Data. Thermal Comfort Data Logger Type 1221. Including Application Software Type 7301 Product Data Thermal Comfort Data Logger Type 1221 Including Application Software Type 7301 USES: For measuring all physical parameters necessary to evaluate heat stress and thermal comfort For evaluating

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Human/Machine Interfaces The essential guide

Human/Machine Interfaces The essential guide Human/Machine Interfaces The essential guide 2 Other Autres versions: réalisations please : consulter votre your agence Schneider Schneider Electric Electric. agency. Human/Machine Interfaces Magelis In

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION

MACHINEMATE. CNC SYSTEM Hardware SPECIFICATION MACHINEMATE CNC SYSTEM Hardware SPECIFICATION Feb 2005 CONTENTS 1 Introduction / General... 3 1.1 Superior Capability in Technology and Productivity... 3 1.2 General hardware components... 4 1.3 Static

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook 1/46 The 6th Edition April 2013 Copyright 2013.4 Digital Electronics Corporation. All Rights Reserved. Preface This guidebook introduces

More information

FLOOR INDICATORS CATALOGUE

FLOOR INDICATORS CATALOGUE FLOOR CATALOGUE All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 18 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/19 LCD LKG240128C

More information

Alliance System Ordering Guide

Alliance System Ordering Guide Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring

More information

DCS Data and communication server

DCS Data and communication server 8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With

More information

R60 USB to CAN interface Manual (1.5 EN)

R60 USB to CAN interface Manual (1.5 EN) R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522

More information

FLOOR INDICATORS CATALOGUE 2007

FLOOR INDICATORS CATALOGUE 2007 FLOOR CATALOGUE 2007 All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 17 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/21 LCD

More information

Product type designation. Display. Control elements

Product type designation. Display. Control elements Data sheet SIMATIC HMI, KTP700 BASIC DP, BASIC PANEL, KEY AND TOUCH OPERATION, 7" TFT DISPLAY, 65536 COLORS, PROFIBUS INTERFACE, CONFIGURATION FROM WINCC BASIC V13/ STEP7 BASIC V13, CONTAINS OPEN SOURCE

More information

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03 MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following

More information

Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4

Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4 Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless

More information

Instruction manual. testo easyheat Configuration and Analysis software

Instruction manual. testo easyheat Configuration and Analysis software Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of

More information

LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators

LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators LCD240X128A Asansörler İçin Grafik LCD Gösterge Graphic LCD Display for Elevators KULLANICI KILAVUZU USER MANUAL TR/EN TÜRKÇE ENGLISH Publisher ARKEL Elektrik Elektronik Ticaret Ltd. Şti. Date of issue

More information

Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels

Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance) Features Excellent C/P ratio (cost/performance) High-resolution color touch screen RTC (Real Time Clock) Supports 1 Serial Port (RS-232/RS-485, including Self-Tuner) Rubber Keypad WYSIWYG (What You See

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units I123 GB 1207 RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units CUSTOMIZATION SOFTWARE MANUAL List of contents Introduction... 2 Main window... 3 Device model selection... 3 Transmission of data

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages

More information

E-Series. Human Machine Interfaces. Evolution By Design MITSUBISHI ELECTRIC AUTOMATION, INC.

E-Series. Human Machine Interfaces. Evolution By Design MITSUBISHI ELECTRIC AUTOMATION, INC. E-Series Human Machine Interfaces E Evolution By Design MITSUBISHI ELECTRIC AUTOMATION, INC. Discover the Many Facets of Mitsubishi Electric. The Power in Automation Solutions. E-Series is a family of

More information

Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos

Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos HMS Industrial Networks AB Page 1 (37) History Revision Date Description Responsible 1.11 2012-09-26 Typos SDA

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Industrial Bar Code Scanners

Industrial Bar Code Scanners DS6400 Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack APPLICATIONS Automated warehousing Medium conveyor sorting Reading on forklift trucks Picking systems Automated shop

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

5000V Graphical Megohmmeter Model 5070

5000V Graphical Megohmmeter Model 5070 5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

Series Six Plus Programmable Controller

Series Six Plus Programmable Controller Series Six Plus Programmable Controller Gl?K-0147B June 1989 Central Processor Unit 8-Slot Rack 1l-Slot Rack General Description The Central Processor Unit (CPU) for the Series Six Plus Programmable Logic

More information

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply 1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,

More information

VEGA Analogue Addressable Control Panels

VEGA Analogue Addressable Control Panels Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed

More information

MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B

MagIC 6100. Installation Manual. Point of Sales Terminals TD06014B MagIC 6100 Installation Manual Point of Sales Terminals TD06014B Contents Description 3 Introduction 3 Presentation of the MagIC 6100 terminal 3 Technical Data 4 Installation 5 Unpacking 5 Safety recommendations

More information

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and

More information

MultiViu Flex 7 Data Sheet

MultiViu Flex 7 Data Sheet Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Device configurator DRC200

Device configurator DRC200 Operating manual 42/49-27 EN Engineer IT Device configurator DRC200 R&C Process Data Management Software Impressum Device configurator DRC200 Operating manual Document No. 42/49-27 EN Date of issue: 11.02

More information

SIMATIC Flat Panel Monitors

SIMATIC Flat Panel Monitors Product Data Sheet The Flat Panels are rugged industry-standard LCD monitors. Design of front panels: - 12", 15", 17" and 19" TFT Touch - 12" and 15" TFT Key Installation: - They are equally suited to

More information

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production

More information

How To Use Safety System Software (S3)

How To Use Safety System Software (S3) SPECIFICATION DATA Safety System Software (S3) APPLICATION Safety System Software (S 3 ) is a robust, full featured configuration, diagnostic, programming and real-time monitoring package for integrators

More information

TSX ETY 110 Module 8

TSX ETY 110 Module 8 Module 8 Introduction Subject of this chapter What s in this Chapter? This chapter describes the implementation of a TSX ETY 110 module. This chapter contains the following sections: Section Topic Page

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

Second Display Installation Guide Point-of-Sale Hardware System

Second Display Installation Guide Point-of-Sale Hardware System Second Display Installation Guide Point-of-Sale Hardware System 48200150 August 2002 V1.0 1. Accessory VGA Cable Serial Cable Warranty Card Drivers Bank The following drivers in the folders of Driver Bank

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2. Motorized Actuators Motor Cables EZS /EZS for Clean Room Use This cable is a dedicated cable for connecting the linear slide of the EZS Series and EZS Series for Clean Room Use with the controller. Use

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Datex-Ohmeda Critical Care Monitor

Datex-Ohmeda Critical Care Monitor GE Healthcare Datex-Ohmeda Critical Care Monitor Comprehensive monitoring for the challenging Critical Care environment Critical Care monitor offers a flexible range of module frame options, displays and

More information

Rack Mount LCD KVM Assembly Installer/User Guide

Rack Mount LCD KVM Assembly Installer/User Guide Rack Mount LCD KVM Assembly Installer/User Guide Japanese Notification Chinese Notification Taiwanese Notification Rack Mount LCD KVM Assembly Installer/User Guide Avocent, the Avocent logo and The Power

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

FLOOR INDICATORS CATALOGUE 2007

FLOOR INDICATORS CATALOGUE 2007 FLOOR CATALOGUE 2007 All Your Needs For Elevators INDEX 1. LCD Indicators... 3 2. Dot Matrix Indicators... 9 3. Accessories... 17 ALBEN İnşaat Makine Elektrik Elektronik San. ve Tic. Ltd. Şti 2/21 LCD

More information

NortechCommander Software Operating Manual MAN-00004 R6

NortechCommander Software Operating Manual MAN-00004 R6 NortechCommander Software Operating Manual MAN-00004 R6 If the equipment described herein bears the symbol, the said equipment complies with the applicable European Union Directive and Standards mentioned

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

CMS Central Monitoring System

CMS Central Monitoring System General In This Section CMS for Windows CMS Hardware CMS Functional Spec Relational Database Monitoring Interface Communication Network CMS Central Monitoring System General CMS Central Monitoring System

More information

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,

More information