KAPA qpcr Library Quantification for NGS Express

Size: px
Start display at page:

Download "KAPA qpcr Library Quantification for NGS Express"

Transcription

1 KAPA qpcr Library Quantification for NGS Express Application Guide PerkinElmer 2200 Warrenville Road Downers Grove, IL Document Number BETA Copyright 2012, PerkinElmer, Inc. All Rights Reserved

2 Trademark Acknowledgement is a registered trademark of PerkinElmer, Inc. VersaTip is a trademark of PerkinElmer, Inc. JANUS is a registered trademark of PerkinElmer, Inc. WinPrep is a registered trademark of PerkinElmer, Inc. SYBR and MicroAmp are registered trademarks of Life Technologies Corporation. Nextera, MiSeq, and illumina are trademarks or registered trademarks of Illumina, Inc.

3 Table of Contents Required Materials List... 4 NGS Express Kits & Reagents... 4 Labware & Consumables... 5 NGS Express Custom Deck Tiles and Racks... 6 Reagent and Sample Preparation... 7 NGS Express Well Maps... 8 KAPA qpcr Sample Plate Well Map... 9 KAPA qpcr Reagent Rack Well Map KAPA qpcr Dilution Plate Well Map KAPA qpcr Assay Plate Well Map Advanced Protocol Logic: Validation of User Entries Error Checking: Required Entries Error Checking: Sample Count Error Checking: Skipped Samples Error Checking: Duplicate Samples PerkinElmer 3

4 Required Materials List Materials Required but Not Supplied: Required Kits & Reagents Item (Kits & Reagents) Vendor/Part Number KAPA SYBR FAST Universal qpcr Kit 1 x 1ml Illumina Primer Premix (10X) 6 x 80ul Illumina DNA Standards KAPA SYBR FAST ABI Prism qpcr Kit 1 x 1ml Illumina Primer Premix (10X) 6 x 80ul Illumina DNA Standards KAPA SYBR FAST Bio Rad icycler qpcr Kit 1 x 1ml Illumina Primer Premix (10X) 6 x 80ul Illumina DNA Standards KAPA SYBR FAST LightCycler qpcr Kit 1 x 1ml Illumina Primer Premix (10X) 6 x 80ul Illumina DNA Standards Water, molecular biology grade (Used for qpcr Water Controls) 10mM Tris HCL, ph % Tween 20 (Used for Serial Dilution Buffer) MicroAmp Optical Adhesive Film (1 Film) KAPA Biosystems KK4824 (KK4601+ KK4808) KAPA Biosystems KK4835 (KK KK4808) KAPA Biosystems KK4844 (KK KK4808) KAPA Biosystems KK4854 (KK KK4808) general lab supplier general lab supplier Life Technologies PerkinElmer 4

5 Labware & Consumables These materials are included in the NGS Express system package. Item (Labware & Consumables) Disposable Tip 25ul, Clear, Sterile Filter Tips, (4 Boxes) Vendor/Part Number PerkinElmer Hard Shell PCR Plates, 96 well, (2 Plates) Bio Rad HSP 9631 MicroAmp Optical 96 Well Reaction Plate (1 Plate) Life Technologies N MicroAmp Splash Free 96 Well Base (1 Support) Life Technologies Lid Universal, Polystyrene, (1 Lid) Seahorse (various distributors) Screw Cap Microtubes, 2.0mL capacity (16 Tubes) Sarstedt Caps for Microtubes, blue (Optional for Reagent Storage) Sarstedt PerkinElmer 5

6 Custom Deck Tiles and Racks These materials are included in the NGS Express system package. Item (NGS Supports & Deck Tiles) NGS Reagent Rack (1 Rack) Vendor/Part Number PerkinElmer VersaLift Tool PerkinElmer 96 Torroid Magnet PerkinElmer VersaMover Base PerkinElmer VersaMover Basket PerkinElmer VersaMover Base PerkinElmer Inheco 96 PCR Plate Support 33mm (1 Support; Not used in KAPA Protocol) PerkinElmer PerkinElmer 6

7 Reagent and Sample Preparation The NGS Express reagent rack requires both kit and non kit regents for KAPA qpcr Library Quantification. A choice of 4 KAPA SYBR FAST qpcr kits is available (Universal, ABI Prism, Bio Rad icycler, and LightCycler), and include Primer Premix, Illumina DNA Standards, ROX High and ROX Low dyes. Only 1 kit is required for operation on the NGS Express. Individual kit components can be purchased/assembled as needed. NGS Express requires the following Setup Guidelines: Notes: All reagents placed on the NGS Express should be transferred into 2ml Sarstedt screw cap microtubes. Critical dimensions, including diameters, heights, depths, well bottoms, etc. are preprogrammed into the automated workflow; using alternative microtubes could impact assay results and may cause damage to the NGS Express system. Alternative tube types can be accommodated, but requires modification to the labware definitions prior to use (consult with your product specialist). All reagents should be thoroughly thawed and vortexed prior to aliquoting into Sarstedt tubes. Failure to do so could impact concentrations and subsequent qpcr results. NGS Express_DNA Library Samples: DNA Libraries 1 8 (10µl): DNA Libraries/Source Samples should be aliquoted into a 96 WellHard Shell PCR plate. The NGS Express will access samples from these wells and needed to complete the requested serial dilutions. 1 8 DNA Libraries (DNA Libraries; Column 1, wells 1 10µl) NGS Express_KAPA qpcr Reagents: DNA Standards 1 6 (30µl): Illumina DNA Standards 1 6 arrive in 80µl aliquots as part of the KAPA SYBR FAST qpcr kit. These standards will be used undiluted (neat) in the NGS Express protocol. 6 X DNA Standards (DNA Standard; 6 30µl) H 2 0/Controls (30µl): Water and/or Control reagents are not supplied in the KAPA SYBR FAST qpcr Kit, and must be supplied independently. Two positions are allocated on the NGS Express Reagent Rack for these controls. Water blanks and or controls are recommended for baseline (blank) reads during qpcr analysis; these samples will be dispensed in similar volumes as DNA Standards 1 6. Recommended Molecular Biology Grade Water (H 2 0; 2 30µl) Optional Configuration: Replace one water control with an internal/custom laboratory specific control sample (H 2 0; 1 30µl, Control; 1 30µl) PerkinElmer 7

8 KAPA qpcr MMX (KAPA qpcr Master Mix + 10X Primer Premix); (250µl): KAPA qpcr Master Mix is composed of sub components from the KAPA SYBR FAST reagent kit. These components include a 1ml tube Illumina 10X Primer Premix, and 5ml bottle of qpcr Master Mix. These components must be premixed prior to using on the NGS Express. Notes: The first time you use the KAPA SYBR FAST qpcr Kit, premix the following components. Mix by vortexing for 10 seconds and record the date and component details. KAPA SYBR FAST qpcr Kit Component Illumina Primer Premix (10X) Volume 1ml KAPA SYBR FAST qpcr MASTER Mix (2X) 5ml 6ml (Total Volume) KAPA qpcr MMX (KAPA qpcr MMX; 4 250µl) Dilution Buffer (250µl): Dilution Buffer reagents are not supplied in the KAPA SYBR FAST qpcr Kit, and must be supplied independently. Four positions are allocated on the NGS Express Reagent Rack for DNA dilution buffer. Dilution buffer aliquots can be alternatively composed of high grade molecular biology water or an optional Tris HCL Tween buffer (Recommended for reducing surface adherence of DNA to plastic surfaces). Molecular Biology Grade Water (H 2 0; 2 250µl) Optional Dilution Reagent: 10mM Tris HCL, ph % Tween 20 (Tris HCL Tween; 4 250µl) NGS Express Well Maps The following pages show the placement of reagents and samples to start the KAPA qpcr run. PerkinElmer 8

9 KAPA qpcr Sample Plate Well Map DNA Samples Loaded in Column 1 of DNA Sample Plate Sample Plate positioned on NGS Express Deck Position [F1] Samples must be in Bio Rad Hard Shell 96 PCR Plate PerkinElmer 9

10 KAPA qpcr Reagent Rack Well Map Thaw, Vortex, and Spin Reagents Tubes Reagents for 1 8 DNA Libraries,, Standards, Controls w/triplicate Serial Dilutions (Total 96 qpcr Reactions) Reagents must be in 2ml Sarstedt screw cap microtubes DNA Standard_1 (30µl) DNA Standard_2 (30µl) KAPA qpcr MMX (250µl) DNA Standard_3 (30µl) DNA Standard_4 (30µl) DNA Standard_5 (30µl) Dilution Buffer (250µl) DNA Standard_6 (30µl) H20/Control (30µl) PerkinElmer 10

11 KAPA qpcr Dilution Plate Well Map Dilution Plate must be EMPTY at start of run Dilution Plate positioned on NGS Express Deck Position [D1] Dilutions will be performed in a Bio Rad Hard Shell 96 PCR Plate Dilutions selected in the drop menu will determine how which dilutions are used for qpcr setup PerkinElmer 11

12 KAPA qpcr Assay Plate Well Map qpcr Plate must be EMPTY at start of run qpcr Plate positioned on NGS Express Deck Position [B1] qpcr reactions will be aliquoted in a MicroAmp Optical 96 Well Plate Dilutions selected in the drop menu will determine the final qpcr Plate format. PerkinElmer 12

13 Advanced Protocol Logic: Validation of User Entries The NGS Express Software will require valid user entries within the NGS Select tab questions. Required entries apply to User Data, KAPA SYBR FAST qpcr Setup Questions, Lot Numbers, and Sample ID s. Open fields for Notes, and fields for Notifications are optional. All user entries will be captured within the summary of the NGS Express automated reports. Error Checking: Required Entries Question: Valid Entry Invalid Entry User ID Any selection from drop down menu Blank (Empty) Note: Red Error Indicator in upper right corner of user entry field Number of Samples (1 8) Any integer value 1 8 Blank (Empty); Any integer value 0, or >8; Any non integer value Reaction Volume (qpcr) Any selection from drop down menu Note: Red Error Indicator in upper right corner of user entry field N/A; Forced drop down menu PerkinElmer 13

14 Question: Valid Entry Invalid Entry Dilution Range (qpcr) Any selection from drop down menu N/A; Forced drop down menu Notes: Any text entry N/A (Optional Entry) Kit Type Any selection from drop down menu N/A; Forced drop down menu KAPA qpcr Kit (Lot Number) Any text or numeric value containing at least 1 character Blank (Empty) Note: Red Error Indicator in upper right corner of user entry field PerkinElmer 14

15 Question: Valid Entry Invalid Entry ROX Dye (Lot Number) Any text or numeric value Blank (Empty) DNA Standards (Lot Number) Any text or numeric value Note: Red Error Indicator in upper right corner of user entry field Blank (Empty) Sample ID (Unique ID s Required) Any unique text or numeric value Note: Red Error Indicator in upper right corner of user entry field Blank (Empty); Skipped Samples; Duplicate Samples Message/ Recipients 1 3 Any text entry Note: Red Error Indicator in upper right corner of user entry field N/A (Optional Entries) PerkinElmer 15

16 Error Checking: Sample Count NGS Express Software will automatically verify DNA Library Sample counts at the start of each KAPA qpcr Library Quantification run. Two independent user entries in the JAA Select tab will be compared (Number of Samples, and the total number of Unique Sample ID s entered). If the user entered sample count value mismatches with the total number of Unique Sample ID s, a User Error Message will appear. (3 Samples Requested) Match (Sample Counts) Mismatch (Sample Counts) 3 ID s 4 ID s Protocol Continues as Normal Corrective Action: Close out of error message pop up window, and return to the JAA Select tab. Re enter values for Number of Samples and/or entries for Unique Sample ID s. PerkinElmer 16

17 Error Checking: Skipped Samples NGS Express Software will automatically verify a continuous sequence of sample ID s has been entered at the start of each KAPA qpcr Library Quantification run. If blank entries are present between sample ID s, a User Error Message will appear. Continuous (Skipped) Red Tab: Entry Error Indicator Protocol Continues as Normal Corrective Action: Close out of error message pop up window, and return to the JAA Select tab. Re enter sample unique names for each of the Sample ID s fields in continuous sequence. PerkinElmer 17

18 Error Checking: Duplicate Samples NGS Express Software will automatically verify unique sample ID s have been entered at the start of each KAPA qpcr Library Quantification run. If duplicate entries are present, a User Error Message will appear. Unique ID s Duplicate ID s Protocol Continues as Normal Corrective Action: Close out of error message pop up window, and return to the JAA Select tab. Re enter sample unique names for each of the Sample ID s fields. PerkinElmer 18

19 NGS Express Reporting Function The Reporting function captures information about the run such as the values of runtime variables and copies of relevant files. Upon run completion, the Reporting function will create a Zip folder located in the C:Packard/Janus/Bin/NGSReports folder. NGS Express will create a Pipetting Summary, Run Report, and Pipetting Log. Several properties of the run are always reported, including protocol name, test ID (from WinPREP database), and WinPREP software version. Refer to the NGS User Installation Guide for custom setup instructions. NGS Express Function The functions for KAPA qpcr Library Quantification requires user configuration for address and network connections. No error will message will be presented if s are not configured or if the network loses connectivity. Refer to the NGS User Installation Guide for custom setup instructions. PerkinElmer 19

Sequencing Library qpcr Quantification Guide

Sequencing Library qpcr Quantification Guide Sequencing Library qpcr Quantification Guide FOR RESEARCH USE ONLY Introduction 3 Quantification Workflow 4 Best Practices 5 Consumables and Equipment 6 Select Control Template 8 Dilute qpcr Control Template

More information

mircute mirna qpcr Detection Kit (SYBR Green)

mircute mirna qpcr Detection Kit (SYBR Green) mircute mirna qpcr Detection Kit (SYBR Green) For detection of mirna using real-time RT-PCR (SYBR Green I) www.tiangen.com QP110302 mircute mirna qpcr Detection Kit (SYBR Green) Kit Contents Cat. no. FP401

More information

RealStar HBV PCR Kit 1.0 11/2012

RealStar HBV PCR Kit 1.0 11/2012 RealStar HBV PCR Kit 1.0 11/2012 RealStar HBV PCR Kit 1.0 For research use only! (RUO) Product No.: 201003 96 rxns INS-201000-GB-02 Store at -25 C... -15 C November 2012 altona Diagnostics GmbH Mörkenstraße

More information

qpcr Quantification Protocol Guide

qpcr Quantification Protocol Guide qpcr Quantification Protocol Guide FOR RESEARCH USE ONLY Topics 3 Introduction 5 User-Supplied Consumables and Equipment 7 Select Template 8 Dilute qpcr Template 9 Dilute Libraries 10 Prepare Reaction

More information

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr) RNA Extraction and Quantification, Reverse Transcription, and Real-time Preparation of Samples Cells: o Remove media and wash cells 2X with cold PBS. (2 ml for 6 well plate or 3 ml for 6cm plate) Keep

More information

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C Product Description The microrna cdna Synthesis Mix has been designed to easily convert micrornas into cdna templates for qpcr

More information

Guide to using the Bio Rad CFX96 Real Time PCR Machine

Guide to using the Bio Rad CFX96 Real Time PCR Machine Guide to using the Bio Rad CFX96 Real Time PCR Machine Kyle Dobbs and Peter Hansen Table of Contents Overview..3 Setup Reaction Guidelines 4 Starting up the Software 5 Setup Protocol on Software 6 Setup

More information

Your Personal Pipetting Robot

Your Personal Pipetting Robot Your Personal Pipetting Robot Quality creates value www.dornier-ltf.com Easiness meets......versatility The PIRO Liquid Handling System provides a versatile pipetting platform with many options for the

More information

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent SPARK DNA Sample Prep Kit Ion Torrent (SPK0002-V08) Frequently Asked Questions Under what circumstances would I use SPARK DNA Sample Prep Kit for Ion Torrent? Enzymatics SPARK DNA Sample Prep Kit for Ion

More information

HBV Quantitative Real Time PCR Kit

HBV Quantitative Real Time PCR Kit Revision No.: ZJ0002 Issue Date: Aug 7 th, 2008 HBV Quantitative Real Time PCR Kit Cat. No.: HD-0002-01 For Use with LightCycler 1.0/LightCycler2.0/LightCycler480 (Roche) Real Time PCR Systems (Pls ignore

More information

Reconstituting and Diluting Primers and TaqMan Probes

Reconstituting and Diluting Primers and TaqMan Probes Reconstituting and Diluting Primers and TaqMan Probes Introduction TaqMan primers are commonly shipped in a lyophilized state. TaqMan probes are sometimes shipped in the lyophilized state, but more often

More information

FOR REFERENCE PURPOSES

FOR REFERENCE PURPOSES BIOO LIFE SCIENCE PRODUCTS FOR REFERENCE PURPOSES This manual is for Reference Purposes Only. DO NOT use this protocol to run your assays. Periodically, optimizations and revisions are made to the kit

More information

Human Herpes Virus 4 (Epstein Barr)

Human Herpes Virus 4 (Epstein Barr) Techne qpcr test Human Herpes Virus 4 (Epstein Barr) nonglycosylated membrane protein (BNRF1) gene 150 tests For general laboratory and research use only 1 Introduction to Human Herpes Virus 4 (Epstein

More information

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... TM Primerdesign Ltd TM Primerdesign Ltd Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene genesig Standard Kit 150 tests DNA testing Everything... Everyone... Everywhere...

More information

Real-time quantitative RT -PCR (Taqman)

Real-time quantitative RT -PCR (Taqman) Real-time quantitative RT -PCR (Taqman) Author: SC, Patti Lab, 3/03 This is performed as a 2-step reaction: 1. cdna synthesis from DNase 1-treated total RNA 2. PCR 1. cdna synthesis (Advantage RT-for-PCR

More information

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... TM Primerdesign Ltd TM Primerdesign Ltd Human Herpes Virus 1 (Herpes simplex type 1) Capsid assembly and DNA maturation gene genesig Standard Kit 150 tests DNA testing Everything... Everyone... Everywhere...

More information

SYBR Green Realtime PCR Master Mix -Plus-

SYBR Green Realtime PCR Master Mix -Plus- Instruction manual SYBR Green Realtime PCR Master Mix -Plus- 0810 F0925K SYBR Green Realtime PCR Master Mix -Plus- Contents QPK-212T 1mLx1 QPK-212 1mLx5 Store at -20 C, protected from light [1] Introduction

More information

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing TM Primerdesign Ltd TM Primerdesign Ltd Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene genesig Advanced Kit 150 tests DNA testing Everything... Everyone... Everywhere...

More information

TaqMan Fast Advanced Master Mix. Protocol

TaqMan Fast Advanced Master Mix. Protocol TaqMan Fast Advanced Master Mix Protocol For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. Information in this document is subject to change without notice. APPLIED

More information

Quantification of Mycobacterium Tuberculosis. 150 tests

Quantification of Mycobacterium Tuberculosis. 150 tests Quantification of Mycobacterium Tuberculosis rep 13E12 For general laboratory and research use only 150 tests Introduction to Mycobacterium Tuberculosis Mycobacterium tuberculosis is the bacterium that

More information

USER GUIDE. Encore PART NOS. 8041 and 8042. SP Rapid Library Systems

USER GUIDE. Encore PART NOS. 8041 and 8042. SP Rapid Library Systems USER GUIDE Encore PART NOS. 8041 and 8042 SP Rapid Library Systems Patents, Licensing and Trademarks 2012 2013 NuGEN Technologies, Inc. All rights reserved. The Encore, Ovation and Applause families of

More information

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests TM Primerdesign Ltd TM Primerdesign Ltd Dengue Virus subtypes 1,2 3 and 4 3 Untranslated Region (3 UTR) genesig Standard Kit 150 tests DNA testing Everything... Everyone... Everywhere... For general laboratory

More information

UltraClean PCR Clean-Up Kit

UltraClean PCR Clean-Up Kit UltraClean PCR Clean-Up Kit Catalog No. Quantity 12500-50 50 Preps 12500-100 100 Preps 12500-250 250 Preps Instruction Manual Please recycle Version: 02212013 1 Table of Contents Introduction... 3 Protocol

More information

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing. User manual imegen Anchovies II ID kit Anchovies species (E. encrasicolus and E. japonicus) DNA detection by sequencing Reference: Made in Spain The information in this guide is subject to change without

More information

Creating a Color Compensation file for Roche LightCycler 480 vers.i & vers. II

Creating a Color Compensation file for Roche LightCycler 480 vers.i & vers. II Creating a Color Compensation file for Roche LightCycler 480 vers.i & vers. II Due to ROX and Cy5 dye emmision spectra overlap Roche LightCycler 480 can pick up signals from a dye measured by another channel.

More information

TITRATION OF raav (VG) USING QUANTITATIVE REAL TIME PCR

TITRATION OF raav (VG) USING QUANTITATIVE REAL TIME PCR Page 1 of 5 Materials DNase digestion buffer [13 mm Tris-Cl, ph7,5 / 5 mm MgCl2 / 0,12 mm CaCl2] RSS plasmid ptr-uf11 SV40pA Forward primer (10µM) AGC AAT AGC ATC ACA AAT TTC ACA A SV40pA Reverse Primer

More information

Lyme Disease. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... RecA gene. 150 tests. Primerdesign Ltd.

Lyme Disease. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... RecA gene. 150 tests. Primerdesign Ltd. TM Primerdesign Ltd TM Primerdesign Ltd Lyme Disease RecA gene genesig Standard Kit 150 tests DNA testing Everything... Everyone... Everywhere... For general laboratory and research use only 1 Introduction

More information

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests. TM Primerdesign Ltd TM Primerdesign Ltd Hepatitis B Virus Core Protein Region genesig Advanced Kit 150 tests DNA testing Everything... Everyone... Everywhere... For general laboratory and research use

More information

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

UltraClean Forensic DNA Isolation Kit (Single Prep Format) UltraClean Forensic DNA Isolation Kit (Single Prep Format) Catalog No. Quantity 14000-10 10 preps 14000-S 1 prep Instruction Manual Please recycle Version: 10302012 1 Table of Contents Introduction...

More information

Taqman TCID50 for AAV Vector Infectious Titer Determination

Taqman TCID50 for AAV Vector Infectious Titer Determination Page 1 of 8 Purpose: To determine the concentration of infectious particles in an AAV vector sample. This process involves serial dilution of the vector in a TCID50 format and endpoint determination through

More information

Agilent High Sensitivity DNA Kit Guide

Agilent High Sensitivity DNA Kit Guide Agilent High Sensitivity DNA Kit Guide Agilent High Sensitivity DNA Agilent Technologies Notices Agilent Technologies, Inc. 2009, 2013 No part of this manual may be reproduced in any form or by any means

More information

AxyPrep TM Mag PCR Clean-up Protocol

AxyPrep TM Mag PCR Clean-up Protocol AxyPrep TM Mag PCR Clean-up Protocol Intro The AxyPrep Mag PCR Clean-up kit utilizes a unique paramagnetic bead technology for rapid, high-throughput purification of PCR amplicons. Using this kit, PCR

More information

Fixed and Adjustable Spacing Electronic Pipettes

Fixed and Adjustable Spacing Electronic Pipettes viaflo Fixed and Adjustable Spacing Electronic Pipettes viaflo Electronic Pipettes All viaflo pipettes function as repeaters, mixers, serial dilutors, manual pipettes, handheld sample processors and more!

More information

How To Get Rid Of Small Dna Fragments

How To Get Rid Of Small Dna Fragments AxyPrep TM Mag FragmentSelect-I Protocol (Fragment Size Selection for Illumina Genome Analyzer and Life Technologies SoLiD) Introduction The AxyPrep Mag FragmentSelect-I purification kit utilizes a unique

More information

Stratagene QPCR Mouse Reference Total RNA

Stratagene QPCR Mouse Reference Total RNA Stratagene QPCR Mouse Reference Total RNA Instruction Manual Catalog #750600 Revision C.0 For Research Use Only. Not for use in diagnostic procedures. 750600-12 LIMITED PRODUCT WARRANTY This warranty limits

More information

Whole genome Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform

Whole genome Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform Whole genome Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform Introduction, 2 Sample Prep Workflow, 3 Best Practices, 4 DNA Input Recommendations, 6

More information

Agarose Gel Electrophoresis with Food Color- Teacher Guide

Agarose Gel Electrophoresis with Food Color- Teacher Guide Page 1 of 7 Project Home Gateway to the Project Laboratory Activities What the Project can do in the classroom Biotechnology Resources Favorite resources online and in print Agarose Gel Electrophoresis

More information

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics MLX BCG Buccal Cell Genomic DNA Extraction Kit Performance Characteristics Monolythix, Inc. 4720 Calle Carga Camarillo, CA 93012 Tel: (805) 484-8478 monolythix.com Page 2 of 9 MLX BCG Buccal Cell Genomic

More information

Applied Biosystems KRAS Mutation Analysis Reagents. Protocol

Applied Biosystems KRAS Mutation Analysis Reagents. Protocol Applied Biosystems KRAS Mutation Analysis Reagents Protocol For Research Use Use Only. Not intended for any animal or human therapeutic or diagnostic use. Information in this document is subject to change

More information

qstar mirna qpcr Detection System

qstar mirna qpcr Detection System qstar mirna qpcr Detection System Table of Contents Table of Contents...1 Package Contents and Storage Conditions...2 For mirna cdna synthesis kit...2 For qstar mirna primer pairs...2 For qstar mirna qpcr

More information

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB10.03.07

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB10.03.07 Techne qpcr test Lyme Disease RecA gene 150 tests For general laboratory and research use only 1 Introduction to Lyme Disease Lyme disease is an infectious disease caused mainly by three species of bacteria

More information

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye amplification tech note 6047 Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye Liz Jordan and Richard Kurtz, Gene Expression Division, io-rad

More information

Transformation Protocol

Transformation Protocol To make Glycerol Stocks of Plasmids ** To be done in the hood and use RNase/DNase free tips** 1. In a 10 ml sterile tube add 3 ml autoclaved LB broth and 1.5 ul antibiotic (@ 100 ug/ul) or 3 ul antibiotic

More information

ncounter Gene Expression Assay Manual Total RNA and Cell Lysate Protocols

ncounter Gene Expression Assay Manual Total RNA and Cell Lysate Protocols ncounter Gene Expression Assay Manual Total RNA and Cell Lysate Protocols v.20090807 For research use only. Not for use in diagnostic procedures. Limited License Subject to the terms and conditions of

More information

Your Power for Health. PCR Labware. Innovation & Quality. www.gbo.com

Your Power for Health. PCR Labware. Innovation & Quality. www.gbo.com Your Power for Health Labware Innovation & Quality www.gbo.com New from Greiner Bio-One WHITE Tube Strips, 96 & 384-well Microplates White polypropylene ideally suited for q Ultra thin tube walls ensure

More information

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR

Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR Creating Standard Curves with Genomic DNA or Plasmid DNA Templates for Use in Quantitative PCR Overview Genomic DNA (gdna) and plasmids containing cloned target sequences are commonly used as standards

More information

Eppendorf PCR Consumables Compatibility Guide for PCR and qpcr Cyclers

Eppendorf PCR Consumables Compatibility Guide for PCR and qpcr Cyclers APPLICATION NOTE No. 266 I November 2012 Eppendorf PCR Consumables Compatibility Guide for PCR and qpcr Cyclers Rafal Grzeskowiak 1, Sandrine Hamels 2, Beate Riekens 1 1 Eppendorf AG, Hamburg, Germany;

More information

Factors Influencing Multiplex Real-Time PCR

Factors Influencing Multiplex Real-Time PCR APPLICATION NOTE Multiplex Real-Time PCR Factors Influencing Multiplex Real-Time PCR Introduction Multiplex PCR is the simultaneous amplification of more than one target sequence in a single reaction [1].

More information

EPIK mirna Select Hi/Lo-ROX Kit. Product Manual

EPIK mirna Select Hi/Lo-ROX Kit. Product Manual EPIK mirna Select Hi/Lo-ROX Kit Product Manual 2 Product Manual www.bioline.com/mirna EPIK mirna Select Hi/Lo-ROX Kit EPIK mirna Select Kit TABLE OF CONTENTS 1 Kit contents 04 2 Description 04 3 Storage

More information

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit Product Bulletin Human Identification Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit The Quantifiler kits produce reliable and reproducible results, helping to

More information

Aurora Forensic Sample Clean-up Protocol

Aurora Forensic Sample Clean-up Protocol Aurora Forensic Sample Clean-up Protocol 106-0008-BA-D 2015 Boreal Genomics, Inc. All rights reserved. All trademarks are property of their owners. http://www.borealgenomics.com support@borealgenomics.com

More information

Application Note. Single Cell PCR Preparation

Application Note. Single Cell PCR Preparation Application Note Single Cell PCR Preparation From Automated Screening to the Molecular Analysis of Single Cells The AmpliGrid system is a highly sensitive tool for the analysis of single cells. In combination

More information

T100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover

T100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover BiotubeTM System Simport offers a wide choice of racks containing 96 x 1.2 ml tubes (8.8 mm top dia. x 45 mm H, or strips of 8 or 12. Tubes, strips, caps and boxes are available as separate units as well.

More information

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... 150 tests. Primerdesign Ltd.

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... 150 tests. Primerdesign Ltd. TM Primerdesign Ltd TM Primerdesign Ltd Lyme Disease RecA gene genesig Advanced Kit 150 tests DNA testing Everything... Everyone... Everywhere... For general laboratory and research use only 1 Introduction

More information

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas ExpressArt Bacterial H-TR cdna synthesis kit With extreme selectivity against rrnas suitable for 2 to 4 µg total RNA Catalogue No. 8004-A30 (30 rxns) Reagents Materials are provided for 30 cdna synthesis

More information

empcr Amplification Method Manual - Lib-A

empcr Amplification Method Manual - Lib-A GS Junior Titanium Series May 2010 (Rev. April 2011) For life science research only. Not for use in diagnostic procedures. 1. WORKFLOW The emulsion-based clonal amplification (empcr amplification) of a

More information

HiPer RT-PCR Teaching Kit

HiPer RT-PCR Teaching Kit HiPer RT-PCR Teaching Kit Product Code: HTBM024 Number of experiments that can be performed: 5 Duration of Experiment: Protocol: 4 hours Agarose Gel Electrophoresis: 45 minutes Storage Instructions: The

More information

Human Luteinizing Hormone (LH) Custom Kit

Human Luteinizing Hormone (LH) Custom Kit Human Luteinizing Hormone (LH) Custom Kit 18089-v2-2015Jan 1 MSD Toxicology Assays Human Luteinizing Hormone (LH) Custom Kit This package insert must be read in its entirety before using this product.

More information

QuickZyme Soluble Collagen Assay

QuickZyme Soluble Collagen Assay QuickZyme Soluble Collagen Assay Version June 2012 FOR RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC PROCEDURES This package insert must be read in its entirety before using this product. Introduction Collagen

More information

Protocol 001298v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

Protocol 001298v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION Please refer to http://www.agencourt.com/technical for updated protocols and refer to MSDS instructions when handling or shipping

More information

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

Related topics: Application Note 27 Data Analysis of Tube Formation Assays. Tube Formation Assays in µ-slide Angiogenesis Related topics: Application Note 27 Data Analysis of Tube Formation Assays. Contents 1. General Information... 1 2. Material... 2 3. Work Flow Overview...

More information

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests Quantification of Hepatitis B Virus Core Protein Region For general laboratory and research use only 150 tests Introduction to Hepatitis B Virus Originally known as serum hepatitis, hepatitis B has only

More information

BR-10150B. Bringing power and flexibility down to size. BIOMEK NX LABORATORY AUTOMATION WORKSTATION

BR-10150B. Bringing power and flexibility down to size. BIOMEK NX LABORATORY AUTOMATION WORKSTATION BR-10150B Bringing power and flexibility down to size. BIOMEK NX P LABORATORY AUTOMATION WORKSTATION Small footprint Easy fit on standard lab benches Many configurations to suit application needs Biomek

More information

Quantification of Propionibacterium acnes. Standard kit 150 tests

Quantification of Propionibacterium acnes. Standard kit 150 tests Primerdesign TM Ltd Quantification of Propionibacterium acnes Recombinase A (reca) gene For general laboratory and research use only Standard kit 150 tests Introduction to Propionibacterium acnes Propionibacterium

More information

EZ Load Molecular Rulers. Catalog Numbers 170-8351 20 bp 170-8352 100 bp 170-8353 100 bp PCR 170-8354 500 bp 170-8355 1 kb 170-8356 Precision Mass

EZ Load Molecular Rulers. Catalog Numbers 170-8351 20 bp 170-8352 100 bp 170-8353 100 bp PCR 170-8354 500 bp 170-8355 1 kb 170-8356 Precision Mass EZ Load Molecular Rulers Catalog Numbers 170-8351 20 bp 170-8352 100 bp 170-8353 100 bp PCR 170-8354 500 bp 170-8355 1 kb 170-8356 Precision Mass EZ Load Molecular Rulers Quantity DNA sufficient for 100

More information

Cluster Generation. Module 2: Overview

Cluster Generation. Module 2: Overview Cluster Generation Module 2: Overview Sequencing Workflow Sample Preparation Cluster Generation Sequencing Data Analysis 2 Cluster Generation 3 5 DNA (0.1-5.0 μg) Library preparation Single Cluster molecule

More information

Absolute Quantification Getting Started Guide

Absolute Quantification Getting Started Guide 5 cdna Reverse Primer Oligo d(t) or random hexamer Synthesis of 1st cdna strand 3 5 cdna Applied Biosystems 7300/7500/7500 Fast Real-Time PCR System Absolute Quantification Getting Started Guide Introduction

More information

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube User Manual CelluLyser Lysis and cdna Synthesis Kit Version 1.4 Oct 2012 From cells to cdna in one tube CelluLyser Lysis and cdna Synthesis Kit Table of contents Introduction 4 Contents 5 Storage 5 Additionally

More information

BigDye Terminator v3.1 Cycle Sequencing Kit. Protocol. DRAFT August 27, 2002 12:32 pm, 4337035A_v3.1Title.fm

BigDye Terminator v3.1 Cycle Sequencing Kit. Protocol. DRAFT August 27, 2002 12:32 pm, 4337035A_v3.1Title.fm BigDye Terminator v3.1 Cycle Sequencing Kit Protocol August 27, 2002 12:32 pm, 4337035A_v3.1Title.fm Copyright 2002, Applied Biosystems. All rights reserved. For Research Use Only. Not for use in diagnostic

More information

Genomic DNA detection assay

Genomic DNA detection assay Genomic DNA detection assay Detection of genomic DNA by real-time PCR Contents CTRL Internal controls and gdna detection Contents Kit Contents 3 Reagents and Equipment to Be Supplied by User 3 Kit Storage

More information

RealLine HCV PCR Qualitative - Uni-Format

RealLine HCV PCR Qualitative - Uni-Format Instructions for use PCR KIT FOR EXTRACTION OF RNA AND REAL TIME PCR DETECTION KIT FOR HEPATITIS C VIRUS RNA Research Use Only Qualitative Uni Format VBD0798 48 tests valid from: December 2013 Rev11122013

More information

ab185916 Hi-Fi cdna Synthesis Kit

ab185916 Hi-Fi cdna Synthesis Kit ab185916 Hi-Fi cdna Synthesis Kit Instructions for Use For cdna synthesis from various RNA samples This product is for research use only and is not intended for diagnostic use. Version 1 Last Updated 1

More information

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products Genolution Pharmaceuticals, Inc. Revolution through genes, And Solution through genes. Life Science and Molecular Diagnostic Products www.genolution1.com TEL; 02-3010-8670, 8672 Geno-Serum Hepatitis B

More information

LABORATORY ORDERING INFORMATION (valid June 2011)

LABORATORY ORDERING INFORMATION (valid June 2011) LABORATORY ORDERING INFORMATION (valid June 2011) GENERAL You can search past orders in the orders ( pinks ) database - search by supplier, item description, catalog number, even name of person who did

More information

miracle mirna qpcr Instruction Manual Store at -20 Version 3.0 (Aug.2013)

miracle mirna qpcr Instruction Manual Store at -20 Version 3.0 (Aug.2013) miracle mirna qpcr Instruction Manual Store at -20 Version 3.0 (Aug.2013) Contents I. PRODUCT INTRODUCTION 1 A. OVERVIEW 1 B. KIT CONTENTS 1 1. REAGENT KITS 1 2. PRIMER SETS 3 3. MIRACLE ON CALL SCREEN

More information

Path-ID Multiplex One-Step RT-PCR Kit

Path-ID Multiplex One-Step RT-PCR Kit USER GUIDE Path-ID Multiplex One-Step RT-PCR Kit TaqMan probe-based multiplex one-step real-time RT-PCR detection of RNA targets Catalog Numbers 4428206, 4428207, 4440022 Publication Part Number 4440907

More information

QIAGEN Supplementary Protocol

QIAGEN Supplementary Protocol QIAGEN Supplementary Protocol Isolation of Peripheral Blood Mononuclear Cells (PBMC) and Purification of Total RNA from PBMC Using the RNeasy Micro or Mini Kit This protocol describes how to isolate PBMC

More information

Western Blot Protocol Protein isolation

Western Blot Protocol Protein isolation Western Blot Protocol Protein isolation A. Preparation of cell lysates. - Preparation of materials: -Dial the microcentrifuge temperature control setting to 4 C -Prepare a bucket of ice -Prepare lysis

More information

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr User Manual Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr User Manual United States/Canada 800.662.2566 Asia Pacific +1.650.919.7300 Europe +33.(0)1.3904.6880 Japan +81.(0)77.543.6116 Clontech Laboratories,

More information

Proto col. GoClone Repor ter Construc ts: Sample Protocol for Adherent Cells. Tech support: 877-994-8240. Luciferase Assay System

Proto col. GoClone Repor ter Construc ts: Sample Protocol for Adherent Cells. Tech support: 877-994-8240. Luciferase Assay System Luciferase Assay System Proto col GoClone Repor ter Construc ts: Sample Protocol for Adherent Cells LightSwitch Luciferase Assay System GoClone Reporter Assay Workflow Step 1: Seed cells in plate format.

More information

Borrelia burgdorferi

Borrelia burgdorferi Techne qpcr test Borrelia burgdorferi Outer surface protein A (ospa) gene 150 tests For general laboratory and research use only 1 Introduction to Borrelia burgdorferi Borrelia burgdorferi is a Gram negative

More information

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476 BioScience quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476 This method describes a Real-time semi-quantitative TaqMan PCR procedure for the determination of

More information

Application Note. Biotechnology Explorer Crime Scene Investigator PCR Basics. Kit: A Real-Time PCR Extension

Application Note. Biotechnology Explorer Crime Scene Investigator PCR Basics. Kit: A Real-Time PCR Extension Biotechnology Explorer Crime Scene Investigator PCR Basics Kit: Table of Contents Introduction.............................................. 2 Learning Objectives......................................

More information

Streptococcus pneumoniae

Streptococcus pneumoniae Techne qpcr test Streptococcus pneumoniae alpha-fucosidase gene 150 tests For general laboratory and research use only 1 Introduction to Streptococcus pneumoniae Streptococcus pneumoniae, or pneumococcus,

More information

Herpes Simplex Virus 1 and 2

Herpes Simplex Virus 1 and 2 Techne qpcr test Herpes Simplex Virus 1 and 2 HSV1 - UL23 thymidine kinase (TK) gene HSV2 - UL36 large tegument protein gene 150 tests For general laboratory and research use only 1 Introduction to Herpes

More information

16S Metagenomic Sequencing Library Preparation Preparing 16S Ribosomal RNA Gene Amplicons for the Illumina MiSeq System

16S Metagenomic Sequencing Library Preparation Preparing 16S Ribosomal RNA Gene Amplicons for the Illumina MiSeq System 16S Metagenomic Sequencing Library Preparation Preparing 16S Ribosomal RNA Gene Amplicons for the Illumina MiSeq System Introduction 2 16S Library Preparation Workflow 5 Amplicon PCR 6 PCR Clean Up 8 Index

More information

Application Guide... 2

Application Guide... 2 Protocol for GenomePlex Whole Genome Amplification from Formalin-Fixed Parrafin-Embedded (FFPE) tissue Application Guide... 2 I. Description... 2 II. Product Components... 2 III. Materials to be Supplied

More information

HBV PCR detection Kit USER MANUAL

HBV PCR detection Kit USER MANUAL For professional use only HBV PCR detection Kit (PREP-NA DNA/RNA Extraction Kit included) USER MANUAL "DNA-Technology, Research & Production" LLC Russia, 142281, Moscow Region, Protvino, 2 Zheleznodorozhnaya

More information

PowerFecal DNA Isolation Kit

PowerFecal DNA Isolation Kit PowerFecal DNA Isolation Kit Catalog No. Quantity 12830-50 50 Preps Instruction Manual Inhibitor Removal Technology (IRT) is a registered trademark of MO BIO Laboratories, Inc. and is covered by the following

More information

Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated. Screening

Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated. Screening Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated in situ TREC qpcr Assay for SCID Screening J Bai, T Henry, J Benfer, S Berberich, T Kreman, and L DesJardin State

More information

Classic Immunoprecipitation

Classic Immunoprecipitation 292PR 01 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Classic Immunoprecipitation Utilizes Protein A/G Agarose for Antibody Binding (Cat.

More information

The GeneAmp PCR System 9700. Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

The GeneAmp PCR System 9700. Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700 The GeneAmp PCR System 9700 Results you can trust. A PCR platform you can grow with. GeneAmp PCR System 9700 The GeneAmp PCR System 9700 fits your lab bench, your applications and your budget. The GeneAmp

More information

Mir-X mirna First-Strand Synthesis Kit User Manual

Mir-X mirna First-Strand Synthesis Kit User Manual User Manual Mir-X mirna First-Strand Synthesis Kit User Manual United States/Canada 800.662.2566 Asia Pacific +1.650.919.7300 Europe +33.(0)1.3904.6880 Japan +81.(0)77.543.6116 Clontech Laboratories, Inc.

More information

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from 200-300μL of Plasma and Serum

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from 200-300μL of Plasma and Serum SUPPLEMENTAL PROTOCOL WHITE PAPER Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from 200-300μL of Plasma and Serum Bee Na Lee, Ph.D., Beckman Coulter Life Sciences Process

More information

User Manual/Hand book. qpcr mirna Arrays ABM catalog # MA003 (human) and MA004 (mouse)

User Manual/Hand book. qpcr mirna Arrays ABM catalog # MA003 (human) and MA004 (mouse) User Manual/Hand book qpcr mirna Arrays ABM catalog # MA003 (human) and MA004 (mouse) Kit Components Cat. No. MA003...Human Whole Genome mirna qpcr Profiling Kit (-20 C) The following components are sufficient

More information

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS 77 78 90 x 14 mm Petri Dish Made in polystyrene. Vented. Supplied in groups of 20 units, packaged in heat sealed bags. Code 200200 is ASEPTIC. Code 200209 is sterile by gamma radiation. Suitable for automatic

More information

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control is a is a state of the art transfection reagent, specifically designed for the transfer of sirna and mirna into a variety of eukaryotic cell types. is a state of the art transfection reagent, specifically

More information

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life... 3

More information

AmpFlSTR Identifiler Direct PCR Amplification Kit

AmpFlSTR Identifiler Direct PCR Amplification Kit USER GUIDE AmpFlSTR Identifiler Direct PCR Amplification Kit for use with: 200 reaction kit (Part no. 4467831) 1000 reaction kit (Part no. 4408580) Publication Part Number 4415125 Rev. J For Forensic or

More information

Gene Expression Macro Version 1.1

Gene Expression Macro Version 1.1 Gene Expression Macro Version 1.1 Instructions Rev B 1 Bio-Rad Gene Expression Macro Users Guide 2004 Bio-Rad Laboratories Table of Contents: Introduction..................................... 3 Opening

More information