1 Request for Quote Windows + Doors Replacement Britannia Water Purification Plant 2731 Cassels Street Ottawa, On RFP-BWPP-WDR Presented by: Marc Légaré
2 B r i t a n n i a W P P W i n d o w s a n d D o o r s R e p l a c e m e n t P a g e 2 General Scope of Work Replace 7 Windows, set of double doors and transom panel, including frames. (Figure 1 Windows and door layout) Scope of work should include, but is not limited to: Type A Windows (Refer to figure 2): Replace existing fire rated windows with new fire rated windows. New frames and associated materials to match existing. Two (2) to be replaced, refer to figure 2 and specification for more detail; Type B Windows (Refer to figure 3): Replace existing operable windows with new operable windows (Awning Style). New frames and associated materials to match existing. Five (5) to be replaced, refer to figure 3 and specification for more detail; Type C Transom Window and double doors (Refer to figure 4): Replace existing transom window with new transom window. Replace existing 34-1/2 wide double doors with a new set a double doors that meet the new Ontario Legislated Accessibility Criteria (See figure 4 for more detail). New frames and associated materials to match existing. Refer to figure 4 and specification for more detail. Contractor to coordinate with 360 Advanced Security Corporation (ASC) for the removal and re-instatement of the security hardware on the double doors. Payment to 360 ASC will be handled separately by the
3 B r i t a n n i a W P P W i n d o w s a n d D o o r s R e p l a c e m e n t P a g e 3 Figure 1 Windows & Door Layout 7 Windows to be replaced - See Figure 2 & 3 for details ; Double doors and transom to be replaced - See Figure 4 for details.
4 B r i t a n n i a W P P W i n d o w s a n d D o o r s R e p l a c e m e n t P a g e 4 Figure 2 Typical Window A Detail Non-Operable window x 2 ; Replace existing 3 panel window with single panel window ; Fire rated fix curtain wall frames ; Fire rated sealed unit glazing ; Frame material/color to match existing.
5 B r i t a n n i a W P P W i n d o w s a n d D o o r s R e p l a c e m e n t P a g e 5 Figure 3 Typical Window B Detail Top window panel to be replaced with non-operable window panel ; Center and bottom window panel to be replaced with single window operable window (awning style) ; Frame material/color to match existing.
6 B r i t a n n i a W P P W i n d o w s a n d D o o r s R e p l a c e m e n t P a g e 6 Figure 4 Typical Door C Detail Transom window panel to be replaced ; Double doors to be replaced with one 38 door to meet new AODA requirement and a side panel that can opened ; Frame material/color to match existing. END OF SCOPE OF WORK
7 B r i t a n n i a W P P W i n d o w s a n d D o o r s R e p l a c e m e n t P a g e 7 General Instructions Examination: Prior to beginning work, examine all conditions likely to affect the work, including the following: 1. Examine the site, which includes work area, adjacent areas and areas used for access, as well as storage and disposal. 2. Identify and record any existing damage. Assume responsibility and cost for repair of any undocumented existing damage on the site. Scheduling: Time is of the essence of the work. Take necessary measures to complete work in accordance with the accepted schedule and as follows: Submittals: Provide all required submittals prior to beginning work at the site. Maintain these and other required documents on site. Submit the following: 1. Construction schedule in acceptable, legible and readily reproducible format, showing dates for mobilization, for start and finish of work and for demobilization. 2. Shop drawings: 1. Take all field measurements required for proper layout and installation of the work. Examine and confirm out-of-square and out- of-plane tolerances in existing components and assemblies. 2. Provide shop drawings for all window assemblies, complete with layout, typical details, drainage, anchorage and tie-in details. 3. Shop drawings are to be sealed and signed by Professional Engineer. 3. Permits and certificates. 4. Site-specific health and safety plan, including health and safety procedures, hazard assessment and control, emergency response and evacuation plan as well as emergency contact information and phone numbers. 5. Product data including technical data as well as WHMIS MSDS. 6. Names of construction site personnel and replacements. 7. Photo record of any existing damage, to acceptance by. Taxes, Permits and Certificates: Pay all taxes and fees. Provide all required permits and certificates, including the following: Use of Site: Building and premises will remain in normal operation during the construction plate. Comply with Manager s requirements regarding use of site, including the following: 1. Use building power, water services only as permitted by Manager. Protect and maintain the services used. 2. Smoking on the site is not permitted. Access and Protection: Provide all access and conveying equipment and protection required for the work including the following: 1. When work is in progress within 4.6 metres (15 ) of a public passage, provide protection of the public, consisting of a minimum of continuous barricades or, where required, fully decked overhead protection, all complete with warning signs. 2. Protect finished work, work in progress, materials being handled or stored and existing adjacent or underlying construction. Provide protection to prevent damage to building surfaces and grounds. 3. Protect building construction and interior from water infiltration. Do not remove more glazing components and seals than can be replaced on the same day.
8 B r i t a n n i a W P P W i n d o w s a n d D o o r s R e p l a c e m e n t P a g e 8 4. Protect against spread of dust, dirt and debris beyond work area or into building interior. Work Procedure: Provide all labour, tools, equipment and materials required for a complete job and as follows: 1. Use only the indicated materials and applications or equals accepted by The City of Ottawa during tender period. Accessories, tools and application procedures are to be as indicated and as recommended by manufacturer of product applied. 2. Carry out work only in optimal environmental conditions recommended by product manufacturers and acceptable to The. Assume responsibility and cost to remove and replace work exposed to unacceptable conditions. 3. Cut, patch and make good as required for the work. Except as indicated, do not cut, drill or modify any part of the existing construction. 4. Carry out work that generates excessive noise, per the Manager s discretion, outside of regular building hours. Clean-up: Clean up as required and as follows: 1. Remove loose debris immediately. Provide for proper, environmentally responsible, off-site disposal of removed materials. 2. Maintain clean and tidy work area. Clean up daily, or more often as the work progresses. 3. Clean all exposed metal and glass surfaces included in the work to existing condition and to acceptance by The. Close-out: Upon completion of work at the site, immediately close out operations to The s acceptance and as follows: 1. Clean up at work area and areas used for parking, storage and disposal. 2. Make good all damage caused by work operations. Repair any undocumented previously existing damage on the site. 3. Remove all tools, equipment, excess materials and debris. Return all keys. 4. Provide two (2) copies of project records, including contact information for contractor and principal subcontractors, warranties, technical data for products used and principal suppliers as well as all contract documents. End of General Instructions
9 Materials Use the indicated materials or equals accepted by The. Aluminum Windows: Match Existing. Accessories: Clip angles. Thermal break and glazing gaskets. Operable Windows (Awning Type): Window assembly components, profiles and sizes as required. Operable awning units to be complete with extruded aluminum insect screen frames and glassfibre mesh, extruded aluminum butt hinge with stainless steel pins. Finish and colour to match existing around building. Aluminium Metal Sill Flashings: To match Existing. Accessories: Sheet metal screw fasteners with anti-corrosion coating Aluminium Sheet for Spandrel Panel: To match existing windows Accessories: Sheet metal screw fasteners with anti-corrosion coating Glazing gaskets: silicone or silicone-compatible dense neoprene or EPDM, Shore A Durometer of 60 plus or minus 5, profile and dimensions as required. Screw Port Corner Blocks: silicone or silicone-compatible dense neoprene or EPDM, Shore A Durometer of 60 plus or minus 5, depth and width to match dimension of screw port and thermal break, length as required. Setting Blocks: silicone or silicone compatible, 80 Durometer, hardness plus/minus 5, profiled to allow drainage. Length 100 mm (4 ) minimum, width as required to support full thickness of glass units, but not so wide as to block drainage. Glazing Tape: New, preshimmed glazing tape with a continuous shim rod. Dimension of shim rod must be greater than dimension of existing gasket raceway. Products: Polyshim 2 by Tremco Silicone Sealant: One component, moisture curing, non-sag, medium modulus, silicone sealant, in standard colour to The s acceptance. Products: Contractors Weatherproofing Sealant by Dow Corning or accepted equal. Accessories: Non-reactive cleaning agent Rigid Insulation: Extruded polystyrene rigid plastic foam boards, with butt edge, 25mm thick. Products: Styrofoam Cavitymate by Dow or accepted equal Spray Applied Foam: One component polyurethane foam sealant. Products: ENERFOAM by Dow or accepted equal Interior Wood Trim: MDF or Pine to match profile of existing. Execution The following is a detailed description of the replacement procedures. Carry out all work where and as directed by The. See attached Photos for reference. Workmanship 1. Carry out work to required standards and as follows: 1. True to line, elevation, level, plumb and square and without warp or rack of frames, to a tolerance of 1:600 or greater as specified by manufacturer. 2. As directed, remove and replace unacceptable work. Assume associated costs. Window Frame Installation 6/29/2015 Request for Proposal Process Tracker Page 2
10 RFP Process Tracker 1. Install window assemblies in accordance with manufacturer s instructions and accepted shop drawings. 2. Install frames as required and anchor, shim and fix frame in correct position, ensuring proper and even clearances to adjoining construction. 3. Install thermal breaks as required and in continuous lengths, without intermediate joints. 4. For pressure plate system, at framing junctures, install corner blocks to close gaps between adjoining screw ports, to direct drainage from the vertical glazing cavities into the horizontal cavities. Install as required and as follows: 1. Size each corner block to form an exact continuation of adjoining screw port and thermal break and as required to ensure proper compression by pressure plates. Ensure tight fit, allowing for thickness of adhesive. 2. As adhesive, apply a coat of sealant to contact surfaces. 3. Install corner blocks aligned square, true and flush to adjoining surfaces. 4. Fully close gaps in the drainage surface by applying a thin smear of sealant extending onto adjoining screw port surfaces. 5. Install interior glazing tape as required and as follows: 1. Install in continuous lengths, without intermediate joints. 2. Ensure tight fits at all corner junctures. 3. Seal joints with cap bead of sealant. 6. Provide metal flashings where required and as follows: 1. At base of all windows, provide sill flashings, with drip edges, extending from under the pressure plate. 2. Size flashings in maximum possible lengths. Install splice plate under necessary intermediate butt joints in flashings. 3. Temporarily support and secure flashings with shims and adhesive. Do not drive fasteners into window components. 7. Size pressure plates and snap caps in continuous length along framing members, without intermediate joints and without gaps at butt joints. Position pressure plates with slots for drainage from horizontal glazing cavities at lower edges of glass units. Glazing 8. Solidly fill cavity between window frame and adjacent construction with continuous spray applied foam. 1. Warranty: 1. In addition to other warranty requirements, provide the following: 1. A five (5) year extended warranty against defects in materials and workmanship for the work of this Section. 2. A ten (10) year extended warranty against edge seal failure for insulating glass units. 2. Insulating Glass Units: 1. Insulating glass units are to be as follows: 1. 6 mm outboard pane, clear tempered mm air space 3. 6 mm inboard pane, clear tempered with Low-E on #3 surface 2. Fabrication of insulating glass units is to be as follows: 6/29/2015 Request for Proposal Process Tracker Page 3
11 RFP Process Tracker 1. Maintain specified separation of two panes of glass with non-corrosive, desiccant filled, stainless steel, warm-edge spacer core having bent corners and welded joints. 2. Dehydrate air space and hermetically seal inner and outer panes at periphery with continuous primary seal of flexible sealant. 3. Provide continuous secondary seal using silicone sealant. 3. Tempered glass to CAN/CGSB Low emissivity coatings ( Low-E ) are to be neutral in colour. Applied so as to ensure maximum uniformity, edge deleted where silicone sealant is in contact with glass. 3. Spandrel Units: 1. Spandrel units are to be as follows: 1. 3 mm thick aluminum exterior face panel mm thick extruded polystyrene insulation 3. 3 mm thick aluminum interior panel 4. Install Insulating glass units as specified and in accordance with IGMAC manual. 5. Install setting blocks and shims in accordance with instructions of insulating glass manufacturer and as required for proper drainage of water from the bottom of glazing cavities. Sealant 1. Warranty: 1. In addition to other warranty requirements, provide the following: 1. A five (5) year extended warranty against defects in materials and workmanship for the work of this Section. 2. Contractor s warranty that sealant will remain fully bonded and leak proof for warranty period. 2. Primers: as recommended by sealant manufacturer. 3. Clean surfaces for primer or sealant as recommended by manufacturers and as required. 4. Install sealant along all jambs and head of window framing, between snap caps and adjacent construction. 5. Install sealant as recommended by manufacturer and for weather seal as follows: 1. Provide joint fillers, outsized 30% to 50% for proper compression, in continuous lengths. Install in glazing cavity positioned between the edges of the glass units. Do not obstruct drainage cavities. 2. Apply sealant over the joint filler to fill remainder of cavity. Do not obstruct the glazing cavities or restrict the drainage of water. Neatly tool surface. 6/29/2015 Request for Proposal Process Tracker Page 4
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationSun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationDIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS
DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the contract, including general and supplementary conditions and other Division 1
More informationReplacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More information7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME
7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationInstallation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows
Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read
More informationClad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
More informationBasement Window Installation Guide Hopper and Sliding
Basement Window Installation Guide Hopper and Sliding americancraftsmanwindows.com Project Requirements: Installation must comply with all applicable building codes. Existing window frame, wall and weatherresistant
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nailing fin. While the use of these installation instructions
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationSECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
More informationImportant Information for Installer & Homeowner
Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side
More informationWINDOW INSTALLATION GUIDE
WINDOW INSTALLATION GUIDE is not responsible for or liable for any use or misuse of the information contained in this window installation guide. Window Installation Guide This guide provides basic information
More informationWINDOW PANNING AND TRIMS
OCTOBER, 2010 PANNING AND TRIMS GENERAL INFORMATION 1 EXTERIOR PANNING Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows.
More informationSECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
More informationJANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs
JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC 97909-071 085113 ALUMINUM WINDOWS Guide Specs SECTION 085113 ALUMINUM WINDOWS This suggested guide specification has been developed using the current edition
More informationDow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
More informationWe urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
More informationINSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW
Vinyl Windows and Doors Manufactured by Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW Lea las instrucciones en español en el reverso.
More informationBrick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
More informationSECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
More informationInstallation Guide for Andersen Architectural Clad Outswing Commercial Doors
Installation Guide for Andersen Architectural Clad Outswing Commercial Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for vinyl windows without a nailing fin (including finless, flush fin and flange). Read these instructions
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationPART 1 PROJECT DESCRIPTION 1.01 GENERAL INFORMATION
Detailed Specifications for Window Replacement for the Metropolitan Sewer District of Greater Cincinnati Little Miami Wastewater Treatment Plant 225 Wilmer Ave. Cincinnati, OH 45226 Administration Building,
More informationWINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING
WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements
More informationInstallation Instructions
Installation Instructions 1. Position the unit onto bridging packers. These keep the unit away from any water sitting inside the frame. 2. Centralise the unit within the frame and pack the edges with appropriate
More informationREDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES
REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES Tools Required Tape Measure Hammer Slotted Screw Driver #2 & #3 Philips Screw Driver 3-4 Foot Level 12 Pry Bar Cold Chisel
More informationTundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
More informationSECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
More informationINSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg
Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to
More informationSECTION 07 42 13 METAL WALL PANELS
Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: info@alpolic.com www.alpolic-northamerica.com This MANU-SPEC utilizes
More informationWe urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.
Important Information for New Construction Installations Attention Installer! We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden
More informationINSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS
2009 Pella Corporation INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS Part Number: 80WH0100 Installation Instructions for Typical Wood Frame Construction.
More informationDE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
More informationInstallation Window Building In Details
Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers
More informationInstallation Guide for Andersen Architectural Wood Inswing Entry Doors
Installation Guide for Andersen Architectural Wood Inswing Entry Doors Congratulations! You have just purchased one of the many fine Andersen products. Proper assembly, installation and maintenance are
More informationAAMA 2400-10. Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure
A M E R I C A N A R C H I T E C T U R A L AAMA 2400-10 Standard Practice for Installation of Windows with a Mounting Flange in Open Stud Frame Construction for Low Wind/Water Exposure M A N U F A C T U
More informationvinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? Standard Features easy, trouble-free operation. window material formulated and
vinyl replacement windows LOOKING FOR VINYL REPLACEMENT WINDOWS? We are confident that we carry a style and size to suit your application. You can be sure that your investment will add value to your home,
More informationEggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art
D O O R F R A M E S Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art D O O R F R A M E S Eggers Industries
More informationWELCOME. Recommended Window Installation. 1.5 credits Minnesota Department of Labor and Industry
WELCOME Recommended Window 1.5 credits Minnesota Department of Labor and Industry In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized
More informationOptimum Windows Reliant Installation Manual
Optimum Windows Reliant Installation Manual 1) Ordering the proper installation components.. PG s 1 2) Receiving, Handling, Storing & Protecting.PG s 2-3 3) Preparing for the Install..PG s 3-4 4) Installing
More informationActive and Passive Sash Replacement
for Andersen Gliding Windows Read all instructions carefully before attempting this procedure. If you have any questions about your ability to complete the procedure, call Andersen at 1-888-888-7020 for
More information4 5/16 Subframe Installation
4 5/16 Subframe Installation The subframe system is a great installation tool for installing windows in masonry conditions. Typically subframes are used in masonry openings so that windows can be anchored
More informationA D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
More informationFree 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
More informationTable of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
More informationISSUE 2. Installation Guide
ISSUE 2 Installation Guide Here at Slide and Fold, we LOVE our Bi-Fold Plus range of folding-sliding doors. We want to ensure that your customers love them too. So we have created a new, detailed installation
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
More informationGreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
More informationSECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK
SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,
More information!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationINSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS
INSTRUCTIONS FOR COORDINATION SECTION 06651 SOLID SURFACE FABRICATIONS 1. Paragraph 1.02 Provide solid surface countertops at sinks locations. Provide solid surface window sills at drywall framing walls.
More informationTHIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150
THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction
More informationHoliday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.
PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation
More informationTested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)
THE B6 GLAZING SYSTEM GLAZING SYSTEMS FOR SEPTEMBER 2013 THE B6 HEEL BEAD SEAL SECURITY GLAZING SYSTEM Page 1 DESCRIPTION The B6 Heel Bead Seal Security Glazing System is suitable for installing all types
More informationResidential Garage Door Terminology
A Air Infiltration: The leakage or passage of air through a door system Anodize: A hard non-corrosive oxide film on the surface of aluminum Astragal: A compressible or deformable seal provided on the bottom
More informationIntroduction...COMB-2 Design Considerations and Examples...COMB-3
SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant
More informationBarewood Octagon and Elongated Windows Installation Instructions
Step-by-step instructions to a beautiful window. Measuring and Installation of your new window from Century Specialty Windows couldn't be easier with our step-by-step instructions. Quality, function and
More informationINSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS
INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.
More informationHeavy Glass Frameless Shower Door With Return Panel
202 Anderson Ave., elvue, KS 66407 Phone: 800-669-9867 Fax: 800-393-6699 www.onyxcollection.com Heavy Glass Frameless Shower Door With Return Panel Full Showers with Return ench Seat with Return FRLSDRPL-0116
More informationAstragal: a vertical member placed at the meeting edges of a double door to provide a weather seal and may be used to anchor the fixed door.
Window and Door Dictionary AAMA: American Architectural Manufacturers Association. A national trade association that establishes voluntary standards for the window, door, and skylight industry. Ambient
More informationStorage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.
Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.
More informationBuilt to Last. Built for Beauty. Good. Solid. Logix. TM
Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a
More informationCLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
More informationPART E SPECIFICATIONS
PART E SPECIFICATIONS Page 1 of 5 PART E - SPECIFICATIONS GENERAL E1. APPLICABLE SPECIFICATIONS, STANDARD DETAILS AND DRAWINGS E1.1 The City of Winnipeg Works and Operations Division Standard Construction
More informationSECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationIMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.
More informationPROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick
1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware
More informationAssessing Curtain Walls
Assessing Curtain Walls Considerations and Best Practices Paul E Beers GCI Consultants, LLC pbeers@gciconsultants.com What is a Curtain Wall System? A curtain wall system is an outer covering of a building
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationConfort 26. Sliding Systems. Sapa Building System
Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are
More information09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec 03500 Master Spec. 03 49 00 Page 1
C. S. I. Spec 03500 Page 1 PART 1 - GENERAL 1.01 SUMMARY:.01 Provide special glassfiber reinforced cement (GRC) shapes in accordance with the requirements of the contract documents..02 The installing contractor
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationK. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11
K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins
More informationInstallation Detailed installation instructions are provided which should be strictly followed.
Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial
More informationH-Stud Area Separation Wall System
12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic
More informationC. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.
SECTION 081216 - INTERIOR ALUMINUM DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
More informationInsulView Window Installation Instructions
InsulView Window Installation Instructions 1. The entire building is normally sheeted with the 2" 2 ½ OR 3 wall panel and the windows installed at a later time. A window retrofit of an existing building
More informationHow To Install Your Frameless Shower Enclosure
How To Install Your Frameless Shower Enclosure a) Installing Single Frameless Door Side Mounted Wall Hinges b) Installing Frameless Door with In-Line Panel c) Installing Frameless Door Between In-Line
More informationPERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM CORPORATION. SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall
Architectural Testing PERFORMANCE TEST REPORT Rendered to: UNITED STATES ALUMINUM CORPORATION SERIES/MODEL: 450 Center Glaze PRODUCT TYPE: Aluminum Curtain Wall Title Summary of Results Air Infiltration
More informationHow To Test For An Architectural Test
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System
More informationArchitectural Casework 06400-01. 1.01 Description of Work
06400-01 1.01 Description of Work A. Extent of each type of architectural millwork and casework as indicated on drawings. Types of architectural casework shall include both stained and plastic laminated
More informationROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationConfort 160. Sliding Systems. Sapa Building System
Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic
More informationPERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Round Top Single PRODUCT TYPE: In-swing Round Top Single Door RH-4 Title Uniform Load Deflection Test
More informationRooflight INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary
More informationPlaisance 50. Windows and doors. Sapa Building System
Plaisance 50 Windows and doors Sapa Building System Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a building depth. The system offers a wide range of inward and outward
More informationGUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced
More informationDESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 8 DOORS AND WINDOWS 08 50 00 WINDOWS
SECTION INCLUDES Metal Windows Vinyl/Aluminum Clad Wood Windows Solid Fiberglass and Vinyl Windows Wood Windows (Historic Preservation only) RELATED SECTIONS 02 83 00 Lead Paint Remediation 06 10 00 Rough
More informationSTANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS
ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the
More informationINSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for Vinyl windows with an integral nail fin. Not all window types may be installed into every wall
More information