ESR-2089 Reissued August 1, 2012 This report is subject to renewal September 1, 2014.

Size: px
Start display at page:

Download "ESR-2089 Reissued August 1, 2012 This report is subject to renewal September 1, 2014."

Transcription

1 a ICC-ES Evaluation Report (800) (562) ESR-2089 Reissued August 1, 2012 This report is subject to renewal September 1, A Subsidiary of the International Code Council DIVISION: METALS Section: Cold Formed Metal Framing DIVISION: WOOD, PLASTICS AND COMPOSITES Section: Shear Wall Panels REPORT HOLDER: HARDY FRAMES, INC. 132 PALMA DRIVE, SUITE 200 VENTURA, CALIFORNIA (805) david.lopp@mii.com EVALUATION SUBJECT: Hardy Frame PANEL, Hardy Frame BRACE FRAME, Hardy Frame POST, Hardy Frame BEARING PLATE, AND Hardy Frame SADDLE 1.0 EVALUATION SCOPE Compliance with the following codes: 2009 International Building Code (2009 IBC) 2009 International Residential Code (2009 IRC) 2006 International Building Code (2006 IBC) 2006 International Residential Code (2006 IRC) 2003 International Building Code (2003 IBC) 2003 International Residential Code (2003 IRC) Property evaluated: Structural 2.0 USES Hardy Frame Panel, Hardy Frame Brace Frame, Hardy Frame Post, Hardy Frame Bearing Plate, Hardy Frame Saddle are steel components intended to resist vertical (gravity) loads horizontal in-plane or out-ofplane wind or earthquake loads in wood-framed or coldformed steel-framed construction. The panels, frames components are an alternative type of construction to conventional wood frame cold-formed steel frame construction, permitted in Chapters of the IBC Chapter 6 of the IRC. Installations include concrete or masonry foundations, raised or upper wood floors, portal frames. The Hardy Frame Panels Brace Frames may be used under the IRC when either an engineered design is provided in accordance with Section R of the IRC or installation complies with Section 4.3 of this report. 3.0 DESCRIPTION 3.1 Hardy Frame Panel Hardy Frame Brace Frame: General: The Hardy Frame Panel Hardy Frame Brace Frame are prefabricated vertical lateral force resisting products for use in wood cold-formed steel light-frame construction. Both product types are designed to resist in-plane out-of-plane lateral wind or earthquake loading while supporting vertical gravity loads. The Hardy Frame Panel is a one-piece, cold-formed steel (c-fs), C-shaped panel that is enclosed at the top bottom with c-fs channels as described in the quality documentation. The Hardy Frame Panel in Balloon Wall applications consists of two Panels in a continuous one piece, shop-welded assembly at the top to bottom channel interface. The Hardy Frame Brace Frame is a rectangular c-fs frame with a single diagonal member c-fs vertical studs spaced at 16 inches (406 mm) on center as described in the quality documentation Hardy Frame Panel Brace Frame HFX HFX/S Series: The Hardy Frame HFX series is intended for single or multi-story wood frame construction with net heights that are equal to stard wood stud height, except for the 9 inch (229 mm) Panel width, which is 1 1 / 2 inch (38 mm) greater than a stard wood stud height. The HFX series may be installed over concrete, or masonry foundations, raised wood floors, wood, or steel beams, may be stacked up to two stories when the lower story is placed on a rigid base, such as a concrete foundation. The 9 inch (229 mm) Panel widths Panels in Balloon Wall applications are limited to installation over concrete foundations, masonry foundations or steel beams. The HFX/S series is intended for use in c-fs framing with net heights that corresponds to stard steel stud heights. HFX/S installations are provided for first floor conditions only over a rigid base, such as a concrete foundation. numbers, dimensions, structural design information for both series are provided in Tables A through 4.0, Figure 1 provides product illustrations. 3.2 Hardy Frame Post General: The Hardy Frame Post is prefabricated for use in wood or c-fs frame buildings. The Hardy Frame Post is a 3 1 / 2 -inch-by-3 1 / 4 -inch (89 mm by 82 mm) c-fs tube that is enclosed at the top bottom with c-fs channels as described in the quality documentation, is designed to resist transfer both axial tension compression loads. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2012 Page 1 of

2 ESR-2089 Most Widely Accepted Trusted Page 2 of Hardy Frame Post HFP Series Hardy Frame Post HFP/S Series: The Hardy Frame Post HFP series is intended for wood-framed construction with net heights that corresponds to stard wood stud heights. The Hardy Frame Post HFP/S series is intended for use with c-fs framing with net heights that correspond to stard c-fs stud heights. numbers, dimensions, structural design information for the HFP HFP/S series are provided in Table 5.1, while Figure 1 provides product illustrations. 3.3 Hardy Frame Bearing Plate: The Hardy Frame Bearing Plate is a flat steel plate that is designed constructed to increase the bearing area in contact with wood surfaces. The bearing plate may be used above or below Hardy Frame Panels. The bearing plates are 3 1 / 2 inches (89 mm) wide 18, 24, or 30 inches (45, 610, or 62 mm) long, with slots holes for fasteners. numbers illustrations for the bearing plate are provided in Figure Screws: Wood Screws: Wood screws are for wood-to-wood or steel-to-wood connections. Uses are with the Hardy Frame Panel, Brace Frame, Bearing Plate or Saddle as indicated in this report. Screws must be USP WS Series (ESR-261) or equivalent. Screw dimensions, design, installation requirements must be as indicated in Table 1 of this report Self-drilling Tapping Screws: The screws used for connecting the Hardy Frame panels brace frames to c-fs collector elements must have a minimum tensile strength (P ts ) value of 4,000 pounds (1 92 N) minimum shear strength (P ss ) of 2,000 pounds (8896 N) when tested in accordance with AISI TS-4, must comply with the ICC-ES Acceptance Criteria for Selfdrilling Tapping Screws (AC118) as evidenced by a current ICC-ES evaluation report. 3.5 Hardy Frame Bolt Brace: The Hardy Frame Bolt Brace is a c-fs strap that installs at the embed end of Panel hold-down anchors to prevent independent rod sway during the concrete pour. Bolt Braces are provided with the same hold-down centerline spacing as the corresponding Panel with which they are installed. 3.6 Hardy Frame Saddle: The Hardy Frame Saddle is a splice connector designed constructed to transfer axial compression tension loads. Applications for the saddle include, but are not limited to, wood top plates, engineered floor roof truss members, headers, beams, studs, posts. Hardy Frame Saddles consist of a one-piece c-fs channel with a 3.1-inch-wide (94 mm) web, 1 1 / 2-3-inch-wide (38 6 mm) flanges. The saddles are available in lengths of 24 inches 36 inches (610 mm 914 mm), with additional details as described in the quality documentation. Slots are provided in the web of the Hardy Frame Saddle to allow for field separation into two L-shapes that may be used for splicing members wider than 3 1 / 2 inches (88.9 mm), or whenever separation may be desirable. Sizes structural design information for the Saddle are provided in Tables of this report. Figure 1 Figure 2 provide product illustrations. 3. Materials: 3..1 Hardy Frame Panels, Brace Frames, Posts: All Hardy Frame Panels, Brace Frames, Posts are formed from 9-mil-thick (2.5 mm) (No. 12 gage) carbon steel complying with either ASTM A 653, Designation SS, Grade 50, or ASTM A 1003, Designation SS, Grade 50, steel with a minimum G60 galvanized coating designation Steel Base Plates: All flat steel plates used in the Hardy Frame Panels, Brace Frames, Posts are 3 / 4 -inch-thick (19 mm) carbon steel complying with ASTM A Panel Stiffeners: All side stiffeners used on Hardy Frame Panels are minimum inch-thick (5. mm) [No. 4 gage] carbon steel complying with ASTM A Hold-down Anchors Rods: High Strength or Stard Hold-down anchors must be used. For use with the tables of this report, the High Strength hold-down anchors must comply with ASTM F 1554, Grade 105; or ASTM A 193, Grade B; or ASTM A 354, Grade BD. Stard hold-down anchors must comply with ASTM F 1554, Grade 36 may be used as indicated in the design tables of this report. For Braced Wall panel substitutions ASTM F 1554 Grade 36 hold-down anchors may be used without substantiating calculations. Nuts must be heavy hex type comply with ASTM A 194 Grade 2H. Coupling nuts must comply with the proof stresses engagement lengths in ASTM A 194 IFI 128. The hardened circular washers must comply with ASTM F 436. The plate washers must comply with ASTM A 36 or better. The washer sizes must comply with the 13 th edition of AISC Steel Construction Manual, Part 14, Table Hardy Frame Bolt Brace: The Hardy Frame Bolt Brace is formed from 3-mil-thick (2.5 mm) No. 12 gage carbon steel complying with ASTM A 653 (or ASTM A 1003), Designation SS, Grade 50 Steel with a minimum G60 galvanized coating designation Non-shrink Grout: Required for double-nut installations, non-shrink grout must comply with ASTM C have a minimum specified compressive strength of 5,000 psi (34.4 MPa) at 28 days. The grout must be prepared in accordance with the manufacturer s instructions. Figure 2 provides illustrations of grout placement. 3.. Hardy Frame Bearing Plate: The Hardy Frame Bearing Plate is a 3 / 4 -inch-thick (19 mm), hot-rolled, flat steel plate complying with ASTM A Hardy Frame Saddle: Saddles are formed from 68-mil-thick (No. 14 gage) (1.3 mm) carbon steel complying with either ASTM A 653, Designation SS, Grade 50, or ASTM A 1003, Designation SS, Grade 50, steel, with a minimum G60 galvanized coating designation. 4.0 DESIGN AND INSTALLATION 4.1 Design: General: The allowable values described in this report for Hardy Frame Panels Brace Frames are reported at Stress Design (ASD) level do not include a one-third stress increase for short-term loading. The allowable in-plane shear values, in-plane drifts, allowable axial compression capacities, allowable uplift due to overturning values for both wind seismic loads are presented in Tables 1.1A to 3.1A of this report. Structural capacities drift values shown in these tables include evaluation of bearing stresses on the supporting base materials for the conditions described in the tables of this report do not require further evaluation by the building design professional. The allowable out-of plane loads are presented in Table 4.0 of this Report. For balloon wall applications, out-of plane loads must be resisted by separate wall elements that are designed detailed by the building design professional.

3 ESR-2089 Most Widely Accepted Trusted Page 3 of 58 shear drift values for Panels Brace Frames of the same configuration, but different heights, listed in the design tables of this report can be determined by linear interpolation between the corresponding values of the lower higher wall heights of the same axial load, between the corresponding values of the lower higher axial load of the same Panel or Brace Frame configuration size. For allowable axial loads less than 1,000 pounds (4450 N), interpolation is not permitted. For seismic loads, the system seismic performance coefficients factors for the IBC are permitted to be R 6.5, Ω 0 3.0, C d 4.0. Second order (P-delta) effects on Panel Brace Frame boundary elements for vertical loads greater than those shown on Tables must be analyzed by the building design professional. Combinations of systems intended to resist seismic forces from the same direction shall comply with Section of ASCE/SEI. Where Hardy Frame Panels or Brace Frames are installed in structures with flexible diaphragms in accordance with Section of ASCE/SEI, the Ω 0 may be reduced from 3.0 as set forth in Footnote g, of Table of ASCE/SEI. Hardy Frame Panels or Brace Frames may be permitted to be designed using the allowable design values corresponding to wind when installed in detached one- two-family dwellings in Design categories A, B, C, or located where mapped short-period spectral response acceleration, S S, is less than 0.4g in accordance with IBC Section , exception 1. The building height is limited to a maximum of 65 feet (19.8 m) for structures located in Design Categories D, E, or F, or as limited in Table 503 of the IBC, whichever is more restrictive. Hardy Frame Panels Brace Frames may be stacked up to two stories as described in Section of this report. The cumulative in-plane shear loads overturning moments must be considered as per the sample calculation in Figure 5, Example 2 of this report. When Hardy Frame Panels or Brace Frames are installed on wood or steel beams, the tabulated design values in Table 1.3A must be used the building design professional must consider the additional drift due to beam deflection within the width of panel or brace frame. Where Hardy Frame Panels or Brace Frames of the same height, but different widths, are placed in the same wall line, the applied shear loads must be proportioned based on relative lateral stiffness (see Figure 5, Example 1 of this Report). The stiffness of Hardy Frame Panels Brace Frames must be calculated by dividing the tabulated allowable in-plane shear by the tabulated drift at this value. Where Panels or Brace Frames are combined in the same wall line with other types of lateral-force-resisting systems, applied shear loads must be proportioned based on relative lateral stiffness of the resisting elements. Combination with other lateral force resisting systems of unknown stiffness is prohibited. Calculations proportioning design lateral loads, based on the known stiffness, must be prepared by a building design professional submitted to the code official for approval. Panels Brace Frames may be installed edge-to-edge. Edge-to-edge installations may include different size products, in which case the design lateral loads must be proportioned based on relative stiffness. When two or more identical Panels or Brace Frames of the same stiffness are used in an edgeto-edge installation, the allowable design value of the system is equal to the sum of the corresponding allowable design values for each individual Panel or Brace Frame. Development of a continuous load path, including collector foundation design must be the responsibility of the building design professional. Illustrative framing details are included as guidance for wood-framed construction in Figure 2, for c-fs-framed construction in Figure 3. The building design professional must prepare details to accommodate a specific job situation, in accordance with the applicable code the requirements of this report, subject to the approval of the code official Hardy Frame Panels or Brace Frames on Foundations: For ASD in-plane shear values of Hardy Frame Panels or Brace Frames on concrete or masonry foundations on washers over nuts, Tables 1.1A, 1.1B, 1.1C 2.1A apply. For ASD in-plane shear values of Hardy Frame Panels in Balloon Wall applications on concrete or masonry foundations, Table 3.1 applies. Where wood elements such as a wood sill are within the load path, the analysis must consider effects of the wood element strength deformation on the overall system capacity, which may require modification of the tabulated values. For Hardy Frame Panels on foundation the Tension (uplift) load in the hold-down anchor may be calculated using equations provided in Figure 4 of this report. For Hardy Frame Brace Frames the Tension (uplift) load in the hold-down anchor may be determined as set forth in the footnote in the design tables. Information on anchorage to foundations is found in Sections of this report Hardy Frame Panels or Brace Frames on Raised Upper Floors: For ASD in-plane shear values of Hardy Frame Panels or Brace Frames on raised or upper floors in wood-framed construction, Tables 1.2A 1.3A apply. For Hardy Frame Panels Brace Frames the Tension (uplift) load in the hold-down anchor must be calculated in accordance with the design tables. For these tables to be used, a Hardy Frame Bearing Plate must be installed beneath the panels where indicated in the table footnotes. The system consisting of the panel or brace frame, raised floor, wood floor, lower panel or brace frame foundation must be analyzed detailed to provide a complete, continuous load path capable of transferring loads from the point of origin to the load-resisting elements. This task is the responsibility of the building design professional must be performed to the satisfaction of the code official. Anchor bolts connecting the panel or brace frame to the supporting structure must be limited to resisting tension loads only. Compression shear loads must be resisted by other load-resisting elements as determined by design. Figure 2 (Detail 3B/P Detail 3B/BF) illustrates use of other load-resisting elements Screw Fastenings: Tabulated wood screw quantities in Table 1.0A for resisting the allowable in-plane wind seismic loads utilize a load duration factor, C D, of 1.6 for wood framed construction in accordance with the ANSI/AF&PA NDS. Screw connections in Hardy Frame Panels may be used to resist ASD tension (uplift) forces resulting from wind. In wood-framed construction, the ASD withdrawal, W, may be computed using the values in ESR-261 for the USP Series, or the building design professional may compute withdrawal values in accordance with the ANSI/AF&PA NDS for other screw types. In c-fs-framed construction, Table 1.0B provides tabulated screw quantities for resisting the allowable in-plane wind & seismic loads. The ASD tension, T, may be computed by Eq-1: T = 105 n (lbf) Eq-1 or T = 465 n (N) where: n = number of screws.

4 ESR-2089 Most Widely Accepted Trusted Page 4 of 58 Eq-1 requires three exposed threads through 43-mil-thick (1.1 mm) (No. 18 gage) minimum base-steel thickness. The nominal screw diameter must be 1 / 4 inch (6.4 mm). The screw head diameter must be a minimum of 5 / 16 inch (.94 mm), unless a washer measuring 5 / 16 inch (.94 mm) in diameter by 0.05 inch (1.2 mm) thick is placed under the head. All of the screws must be uniformly spaced along the length of the channel. When the screws are subjected to combined shear withdrawal loads, the building design professional must calculate the fastener capacity in accordance with Section of the ANSI/AF&PA NDS for connections to wood, AISI S100 for connections to steel under the 2009 IBC or IRC or NAS-01 for connections to steel under the 2006 or 2003 IBC or IRC Anchorage to Concrete: Anchorage to concrete for Hardy Frame Panels or Brace Frames must be designed installed to resist tension or shear loads, as applicable, in accordance with Sections , , 1912 of the 2009 IBC, Sections of the 2006 IBC or Section 1913 of the 2003 IBC, as applicable. Foundation design must address requirements in Sections of the report. The Hardy Frame anchorage details in Figure 2 (Details 1-FDN 1A/FDN, 1B/FDN, 1D/FDN 2-FDN) comply with the 2009, IBC. For anchorage requirements, Figure 2 details 1A/FDN 1B/FDN provide concrete anchorage dimensions; detail 1D/FDN provides supplemental shear tie requirements, 2/FDN provides anchorage call-out for each Panel Brace Frame. For anchorage details not addressed in Figure 2, the building design professional must design the holddown anchorage to accommodate the specific condition critical load dem in accordance with the provisions of the applicable code. Hardy Frame Panels Brace Frames provide ductile attachments to anchorage complying with ACI 318 D Shear tie design as shown in Figure 2, Detail 1D-FDN of this report is not required for installations on wood floors, interior foundation applications, or Braced Wall panel applications per IRC or section of the IBC. The building design professional is permitted to calculate detail alternative anchorage solutions for specific conditions per Section 1912 of the IBC Anchorage to Masonry: Cast-in-place anchorage to masonry foundations or walls for Hardy Frame Panels or Brace Frames described in this report must be designed detailed by a building design professional in accordance with Chapter 21 of the IBC Connection to Steel Supports: Connections to steel beams for Hardy Frame Panels or Brace Frames described in this report must be designed detailed by a building design professional in accordance with Chapter 22 of the IBC Portal Frame System: Any Hardy Frame Panel or Brace Frame may be used in a single, double, or multiple bay portal frame system. When two or more identical Panels or Brace Frames of the same size are used, the ASD allowable design load of the system is equal to the sum of the corresponding allowable design loads for each individual Panel or Brace Frame. When different size Panels /or Brace Frames are used in the same line of a wall, the applied load must be proportionately distributed to each frame based on relative stiffness. Section provides more information on proportioning loads. The portal frame system must be designed detailed by the building design professional in accordance with the applicable code ASD Hardy Frame Saddle Values: The ASD axial tension compression values of the Saddle are described in Tables Braced Wall Panels: When Braced Wall Panels or Alternate Braced Wall Panels are required by Section 2308 of the 2009, 2006 or 2003 IBC, Section R602 of the 2009, 2006 or 2003 IRC, they are permitted to be replaced on a one-to-one basis, with Hardy Frame Panels or Brace Frames. 4.3 Installation: General: All Hardy Frame Panels, Brace Frames, Posts may be installed in one or multi-story structures of wood frame or c-fs frame with masonry or concrete foundations as described in Sections of this report. Locations of all products must comply with this report the plans specifications approved by the code official. Supports for all Hardy Frame Panels, Brace Frames, Posts include but are not limited to concrete or masonry foundations, on washers over heavy hex nuts, on solid-sawn wood, engineered wood, open web wood floor trusses, or hot-rolled steel floor systems. Installation details shown in Figures 2 3 are intended to provide guidance for certain typical surrounding framing conditions. A building design professional must establish details specifications, utilizing the Hardy Frame products, in accordance with the applicable code this report, subject to the code official s approval to accommodate specific conditions critical load combinations specific to the particular structure. The nuts at the bolted base connections must be installed snug tight after the application of the dead load above the Panel or Brace Frame before the structure is enclosed. The snugtightened condition is the tightness that is attained with a few impacts of an impact wrench or the full effort of an installer using an ordinary spud wrench to bring the plies into firm contact. More than one cycle through the bolt pattern may be required to achieve the snug-tightened connection Holes in Hardy Frame Panels Brace Frames: Hardy Frame Panels Brace Frames are fabricated with holes to allow electrical mechanical component access. Panels also contain nominally 1 / 4 -inchdiameter (6.4 mm) screw holes in the flanges. The inch-wide ( mm) Panels have two 3-inchdiameter (6 mm) holes in the face (web) that accept perpendicular penetrating items. A single 1-inch-diameter (25 mm) hole may be field-installed by others in the upper half of the Panel, provided it is located 4 inches (102 mm) minimum from any edge, for the inch ( mm) Panel widths, 1 inch (25.4 mm) minimum above or below, but not to the side of, the existing 3-inch-diameter (6 mm) hole Installation in Wood-Framed Construction: The tables for Hardy Frame HFX Series describe products with net heights that are intended for portal frame installations, installation on concrete with a 2x wood filler above installation on concrete without requiring a 2x filler above. The shear transfer at the top of the Panel must be accomplished by connecting to a collector with minimum 3-inch-long (6 mm) wood or lag screws to transfer the lateral load to the resisting element. Top connection fasteners include threaded fasteners, when substantiated by design details, which are subject to the approval of the code official. Height differences between the Panel or Brace Frame the collector may be resolved by specifying custom heights or by utilizing solid filler pieces above the Panel or Brace Frame. When using a wood filler piece that has a net 1 1 / 2 -inch (38 mm) height above the Hardy Frame Panel or Brace Frame, the filler piece must be connected with minimum 4 1 / 2 -inch-long (114 mm) wood screws. The number of screws must be determined for the critical load dem. Larger filler pieces may be used to make up a greater height difference

5 ESR-2089 Most Widely Accepted Trusted Page 5 of 58 provided all shear transfers, reactions, in-plane drifts out-of-plane stability due to in-plane out-of-plane loading are adequately accounted for by the building design professional. A minimum of four nominally 1 / 4 -inchdiameter (6.4 mm) holes are provided at Panel edges to facilitate the attachment of king studs, when required Installation in Cold-formed Steel-Framed Construction: Tables for Hardy Frame HFX/S Series products provide ASD values for the products built to c-fs stud heights from 96 5 / 8 inches to / 8 inches (2454 mm to 398 mm). The shear transfer at the top of the Panel must be accomplished by connections to a collector for the transfer of lateral load to the resisting element. The collector must be minimum 43-mil-thick (1.1 mm) (No. 18 gage) c-fs, fasteners are required to be 1 / 4 -inchdiameter (6.4 mm) self-drilling tapping screws described in an ICC-ES evaluation report issued in accordance with the ICC-ES Acceptance Criteria for Tapping Screw Fasteners (AC118). Filler pieces may be used to make up height differences between the Hardy Frame Panel or Brace Frame the collector, provided all resulting shear transfers, reactions, in-plane drifts out-of-plane stability due to in-plane out-of-plane loading are adequately accounted for by the building design professional. Installation in cold-formed steel-framed construction is limited to Hardy Frame products installed on concrete or masonry foundations Installation on Concrete or Masonry Foundations: For installation on concrete or masonry foundations, the Panels, Brace Frames, or Posts must be attached at the base with nuts over washers to anchors that are embedded in the concrete or masonry below. The Hardy Frame Bolt Brace may be used to position the embedded portion of the anchors. The anchors must be either cast-in types installed either at time of concrete or grout placement; or post-installed mechanical or adhesive types (only for concrete foundations) recognized in a current ICC-ES evaluation report complying with the building design professional s specifications. Details in Figure 2 apply for installation directly on concrete or masonry, or a nut washer Installation on Raised Upper Floor Systems: For installation on solid sawn lumber or engineered wood platform floor systems, a complete adequate continuous load path must be established to transfer all forces reactions from Hardy Frame Panels, Brace Frames, or Posts to the foundation. The hold-down anchoring methods include, but are not limited to, connecting the base to Hardy Frame Panels, Hardy Frame Brace Frames, Hardy Frame Posts, wood posts, a 4-by rim joist, or to a beam located below. The connection may be made with threaded rods or with approved connectors that are screwed or welded to the Hardy Frame Panel, Brace Frame, or Post attached to members below with a connection specified by the building design professional. When through-bolting to the underside of a beam, a Hardy Frame Bearing Plate or other compression load distributing device must be installed on the underside of the wood member. Anchoring may also be achieved by connecting the panels or frames to the foundation with an extended length of threaded rod for tension loads or in conjunction with wood or steel vertical members for compression loads. The shear transfer at the base of the product must be achieved by attaching the bottom channel to wood members below with 1 / 4 -inch-diameter (6.6 mm) wood screws. The installation of a nominally 4-by (minimum) lumber member in the floor system below is required to provide full bearing to meet required edge distances for the screws to transfer the shear load. For multiple-ply nominally 2-by lumber members, installation of additional connectors may be necessary to compensate for decreased screw edge distances Installation of Hardy Frame Saddle: The Hardy Frame Saddle must be placed over wood members fastened into both edges the top or bottom surface, depending on the installation orientation, with fasteners described in Tables When the member depth exceeds 3 1 / 2 inches (89 mm) or framing conditions dictate, the Saddle may be separated into two L-shapes, each attached to one edge the top or bottom surface of the wood members with the appropriate fasteners. 4.4 Special Inspection IBC: In Design Categories C, D, E, F, periodic special inspections must be provided in accordance with Sections 105.3, 105.4, 10.1, with the exception of those structures that qualify under Section 104.1, or If special inspection is required, the inspector is responsible for verifying proper hold-down anchor size placement with respect to embedment length, spacing edge distance; snug-tight condition of bolting as set forth in Section The inspector must also verify proper connection to the member above in accordance with the details in Figures 2 3 the approved plans specifications IRC: In jurisdictions governed by the IRC, special inspections are not required, except where an engineered design according to Section of the IRC is used. Where an engineered design is used, special inspections in accordance with Section must be provided. 5.0 CONDITIONS OF USE The Hardy Frame Brace Frame, Hardy Frame Panel, Hardy Frame Post, Hardy Frame Bearing Plate, Hardy Frame Saddle described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Hardy Frame product sizes are limited to the widths heights set forth in this report, including a maximum of two stories for wood-framed stacked installations, c-fs installations. 5.2 ASD design loads drifts must not exceed the allowable loads drifts noted in this report. 5.3 Building design calculations details, justifying that the use of the Brace Frames, Panels Posts is in compliance with the code this evaluation report, must be submitted to the code official for approval, except for braced alternate braced wall substitutions noted in Section 4.2 of this report. The calculations details must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. 5.4 The Braced Frames Panels used in exterior walls must be covered with an approved exterior wall covering in accordance with Chapter 14 of the IBC or Chapter of the IRC. 5.5 The Hardy Frame products must be installed in accordance with this report, the manufacturer s instructions, the building plans approved by the code official. 5.6 Design of the concrete or masonry foundation system, supporting members for raised upper floor installation, is beyond the scope of this report. The design must include forces induced by the Hardy Frame products described in this report.

6 ESR-2089 Most Widely Accepted Trusted Page 6 of The Hardy Frame Panel, Brace Frame, Post, Bearing Plate, Saddle, are manufactured under a quality control program at Huntington Beach or Corona, California, with inspections by RI Ogawa Associates (AA-05). 6.0 EVIDENCE SUBMITTED 6.1 Hardy Frame Brace Frames, Panels, Posts, Bearing Plates: Data in accordance with the ICC-ES Acceptance Criteria for Prefabricated, Cold-formed, Steel Lateral-force-resisting Vertical Assemblies (AC322), dated October Hardy Frame Saddle: Reports of load tests, structural calculations, installation details, a quality control manual..0 IDENTIFICATION Hardy Frame Panels, Brace Frames, Posts, Bearing Plates, Saddles are identified by labels bearing the following information: manufacturer s name (Hardy Frames, Inc.) address, product name, model number, evaluation report number (ICC-ES ESR-2089), name of the inspection agency (RI Ogawa & Associates, Inc.). TABLE 1.0A Hardy Frame HFX-SERIES - DIMENSIONS & CONNECTORS Net Height Width Depth HD Dia 1 Top Screw Qty 2,3 (ea) Bottom Screw Qty 2,4 (ea) HFX-9x / 2 HFX-9x / 4 HFX-12x / / 8 5 NA HFX-12x / 4 HFX-12x / / / HFX-12x / 4 HFX-18x8 8 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 10 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / / / 8 10 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 NA HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-24x HFX-24x / 4 15 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 14 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-24x / / / 8 14 HFX-24x / 4 HFX-24x / 4 NA HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / / 2 /

7 ESR-2089 Most Widely Accepted Trusted Page of 58 TABLE 1.0A Hardy Frame HFX-SERIES - DIMENSIONS & CONNECTORS (Continued) Net Height Width Depth HD Dia 1 Top Screw Qty 2,3 (ea) Bottom Screw Qty 2,4 (ea) HFX-44x / 4 HFX-44x / HFX-44x / 4 HFX-44x / 4 HFX-44x / / 2 / HFX-44x / 4 For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Hold Down (HD) rods can be Stard (STD) or High Strength (HS). STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section of this report. 2 The No. 14 by 3-inch-long wood screws must have a minimum design lateral load of 311 lbs. (excluding any duration of load stress increase) based on a inch (No. 12 gage) thick steel to wood (specific gravity of 0.50 or greater) connection. Acceptable screws include USP-WS- Series (ICC-ES ESR-261) or equal. 3 When installing a 2-by wood filler piece with a specific gravity of 0.50 or greater at the top connection the minimum screw length must be 4 1 / 2 inches. 4 Bottom screw length must be 4 1 / 2 inches at Panel Brace Frame connections 3-inches at Hardy Frame Bearing Plate. TABLE 1.0B Hardy Frame HFX/S-SERIES - DIMENSIONS & CONNECTORS Net Height Width Depth HD Dia 1 Top Screw Qty 2,3 (ea) HFX/S-9x / / / 8 5 HFX/S-12x / 8 HFX/S-12x / / / 8 6 HFX/S-12x / 8 HFX/S-18x / 8 12 HFX/S-18x / 8 HFX/S-18x / 8 HFX/S-18x / 8 HFX/S-18x / / / 8 10 HFX/S-18x / 8 HFX/S-24x / 8 20 HFX/S-24x / 8 18 HFX/S-24x / 8 HFX/S-24x / 8 HFX/S-24x / 8 HFX/S-24x / 8 HFX/S-32x / 8 HFX/S-32x / / / HFX/S-32x / 8 HFX/S-32x / / 2 / 8 HFX/S-32x / 8 HFX/S-32x / 8 HFX/S-44x / 8 HFX/S-44x / 8 14 HFX/S-44x / 8 HFX/S-44x / 8 HFX/S-44x / / 2 / 8 11 HFX/S-44x / 8 For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Hold Down rods can be Stard (STD) or High Strength (HS). STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section of this report. 2 The No. 14 metal screws must be self-drilling tapping screws with a minimum design lateral load of 302 lbs excluding any duration of load stress increase is based on a connection consisting of inch (No. 12 gage) thick steel in contact with the screw a inch (No. 18 gage) thick steel not in contact with the screw head. Screws must be referenced in a current evaluation report comply with the requirements in Section of this report. 3 Installed screws must extend through the steel thickness a minimum of three exposed threads.

8 ESR-2089 Most Widely Accepted Trusted Page 8 of 58 TABLE 1.1A HardyFrame INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 9" Wide Panels HFX-9x / , ,460 2,000 HFX-9x / , ,510 12" Wide Panels 1,000 1, ,425 1, ,595 3,500 1, ,005 1, ,005 HFX-12x8 8 6,500 1, ,325 1, ,325 1,000 1, ,595 1, ,595 3,500 1, ,005 1, ,005 6,500 1, ,325 1, ,325 1,000 1, ,425 1, ,595 3,500 1, ,005 1, ,005 HFX-12x / 4 6,500 1, ,325 1, ,325 1,000 1, ,595 1, ,595 3,500 1, ,005 1, ,005 6,500 1, ,325 1, ,325 1,000 1, ,425 1, ,595 3,500 1, ,005 1, ,005 HFX-12x / 4 6,500 1, ,325 1, ,325 1,000 1, ,595 1, ,595 3,500 1, ,005 1, ,005 6,500 1, ,325 1, ,325 1,000 1, ,425 1, ,595 3,500 1, ,005 1, ,005 HFX-12x / 4 6, , ,325 1,000 1, ,595 1, ,595 3,500 1, ,005 1, ,005 6, , ,325 18" Wide Panels 1,000 2, ,830 3, ,585 3,500 2, ,630 3, ,585 HFX-18x8 8 6,500 2, ,630 3, ,585 1,000 3, ,930 4, ,015 3,500 3, ,140 4, ,00 6,500 3, ,880 3, ,45 1,000 2, ,605 2, ,620 3,500 2, ,605 2, ,620 HFX-18x / 4 6,500 2, ,605 2, ,620 1,000 3, ,25 3, ,015 3,500 3, ,90 3, ,00 6,500 3, ,260 3, ,45 1,000 2, ,130 2, ,620 3,500 2, ,845 2, HFX-18x / 4 6,500 2, ,55 2, ,620 1,000 3, ,190 3, ,015 3,500 2, ,030 3, ,00 6,500 2, ,260 2, ,45

9 ESR-2089 Most Widely Accepted Trusted Page 9 of 58 TABLE 1.1A HardyFrame INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-24x8 8 HFX-24x / 4 HFX-24x / 4 18" Wide Panels (Continued) 1,000 1, ,285 2, ,620 3,500 1, ,155 2, ,620 6,500 1, ,055 2, ,620 1,000 2, ,190 2, ,015 3,500 2, ,030 2, ,00 6,500 2, ,260 2, ,45 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 6,500 1, ,310 1, ,620 1,000 2, ,190 2, ,015 3,500 2, ,030 2, ,00 6,500 2, ,260 2, ,45 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 6,500 1, ,430 1, ,620 1,000 2, ,190 2, ,015 3,500 2, ,030 2, ,00 6,500 2, ,260 2, ,45 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 6,500 1, ,430 1, ,620 1,000 2, ,190 2, ,015 3,500 2, ,030 2, ,00 6,500 1, ,260 1, ,45 24" Wide Panels 1,000 3, ,365 4, ,020 3,500 3, ,365 4, ,020 6,500 3, ,365 4, ,020 1,000 5, ,565 6, ,95 3,500 5, ,645 6, ,585 6,500 5, ,600 6, ,925 1,000 3, ,085 3, ,180 3,500 3, ,085 3, ,180 6,500 3, ,085 3, ,180 1,000 4, ,10 6, ,490 3,500 4, ,10 6, ,025 6,500 4, ,10 6, ,245 1,000 2, ,560 3, ,985 3,500 2, ,560 3, ,985 6,500 2, ,560 3, ,985 1,000 4, ,300 5, ,335 3,500 4, ,300 5, ,805 6,500 4, ,300 5, ,925

10 ESR-2089 Most Widely Accepted Trusted Page 10 of 58 TABLE 1.1A HardyFrame INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 24" Wide Panels (Continued) 1,000 2, ,055 3, ,620 3,500 2, ,055 3, ,435 6,500 2, ,65 3, ,345 1,000 4, ,20 5, ,865 3,500 4, ,20 4, ,180 6,500 4, ,20 4, ,055 1,000 2, ,480 2, ,620 3,500 2, ,480 2, ,620 6,500 2, ,140 3, ,620 1,000 3, ,985 4, ,865 3,500 3, ,985 4, ,180 6,500 3, ,985 4, ,055 1,000 2, ,855 2, ,620 3,500 2, ,555 2, ,620 6,500 2, ,455 2, ,620 1,000 3, ,95 4, ,865 3,500 3, ,95 4, ,180 6,500 3, ,95 4, ,055 1,000 2, ,180 2, ,620 3,500 2, ,820 2, ,620 6,500 2, ,20 2, ,620 1,000 3, ,960 3, ,865 3,500 3, ,960 3, ,180 6,500 3, ,960 3, ,055 32" Wide Brace Frames 1,000 2, ,35 2, ,630 3,500 2, ,130 2, ,130 6,500 1, ,130 1, ,130 1,000 3, ,295 3, ,295 3,500 2, ,95 2, ,95 6,500 1, ,95 1, ,95 1,000 2, ,15 2, ,630 3,500 1, ,130 1, ,130 6,500 1, ,130 1, ,130 1,000 2, ,295 2, ,295 3,500 2, ,95 2, ,95 6,500 1, ,95 1, ,95 1,000 1, ,005 2, ,630 3,500 1, ,130 1, ,130 6,500 1, ,130 1, ,130 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6,500 1, ,95 1, ,95 1,000 1, ,255 2, ,630 3,500 1, ,130 1, ,130 6, , ,130 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6,500 1, ,95 1, ,95

11 ESR-2089 Most Widely Accepted Trusted Page 11 of 58 TABLE 1.1A HardyFrame INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-32x / 4 HFX-32x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 32" Wide Panels (Continued) 1,000 1, ,40 1, ,630 3,500 1, ,130 1, ,130 6, , ,130 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6,500 1, ,95 1, ,95 1,000 1, ,665 1, ,630 3,500 1, ,130 1, ,130 6, , ,130 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6, , ,95 44" Wide Brace Frames 1,000 2, ,250 3, ,665 3,500 2, ,250 3, ,365 6,500 2, ,365 2, ,365 1,000 4, ,645 4, ,645 3,500 3, ,145 3, ,145 6,500 2, ,145 2, ,145 1,000 2, ,625 3, ,165 3,500 2, ,625 2, ,365 6,500 1, ,365 1, ,365 1,000 3, ,645 3, ,645 3,500 3, ,145 3, ,145 6,500 2, ,145 2, ,145 1,000 2, ,950 3, ,600 3,500 2, ,950 2, ,365 6,500 1, ,365 1, ,365 1,000 3, ,645 3, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145 1,000 2, ,240 3, ,865 3,500 2, ,240 2, ,365 6,500 1, ,365 1, ,365 1,000 3, ,645 3, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145 1,000 2, ,490 2, ,865 3,500 2, ,365 2, ,365 6,500 1, ,365 1, ,365 1,000 2, ,645 2, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145

12 ESR-2089 Most Widely Accepted Trusted Page 12 of 58 TABLE 1.1A HardyFrame INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-44x / 4 For SI: 1 inch = 25.4 mm, 1 lb = 4.45 N, 1 psi = 6.89 kpa. 44" Wide Panels (Continued) 1,000 2, ,15 2, ,865 3,500 1, ,365 1, ,365 6,500 1, ,365 1, ,365 1,000 2, ,645 2, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145 1 The values in this table are Stress Design (ASD) excluding a 1.33 stress increase pertain to installation directly or to nut washer with 5,000 psi minimum non-shrink grout in accordance with Section 3.. Figure 2 of this report, over normal weight concrete with minimum 2,500 psi specified compressive strength. 2 For installation on a nut washer (only) table values must be multiplied by The additional vertical axial loads are concurrent with the allowable in-plane shear load. For Panels the axial load must be applied within the middle 1 / 3 of the panel width or be uniformly distributed across the entire panel width. For Brace Frame the axial load must be acting along the centerline of the post. 4 The values listed are due to overturning assume no resisting axial load. To determine anchor tension loads in panels at design shear values including the effect of axial loads, refer to Figure 4 of this report. For Brace Frames the anchor tension load equals the tabulated uplift minus P, where P is the allowable axial compression load in the Post. 5 in-plane shear drift values may be linearly interpolated for intermediate height or axial loads. 6 STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section 3..4of this report. TABLE 1.1B Hardy Frame INSTALLATION - ON 3,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 9" Wide Panels HFX-9x / 2 1, ,890 1, ,305 2,000 HFX-9x / , ,305 12" Wide Panels 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,05 HFX-12x8 8 6,500 1, ,430 1, ,35 1,000 2, ,50 2, ,50 3,500 1, ,05 1, ,05 6,500 1, ,35 1, ,35 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,05 HFX-12x / 4 6,500 1, ,430 1, ,35 1,000 1, ,50 1, ,50 3,500 1, ,05 1, ,05 6,500 1, ,35 1, ,35 1,000 1, ,430 1, ,050 3,500 1, ,430 1, ,05 HFX-12x / 4 6,500 1, ,430 1, ,35 1,000 1, ,50 1, ,50 3,500 1, ,05 1, ,05 6,500 1, ,35 1, ,35

13 ESR-2089 Most Widely Accepted Trusted Page 13 of 58 TABLE 1.1B Hardy Frame INSTALLATION - ON 3,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-12x / 4 HFX-18x8 8 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 12" Wide Panels (Continued) 1,000 1, ,425 1, ,620 3,500 1, ,425 1, ,05 6,500 1, ,425 1, ,35 1,000 1, ,810 1, ,50 3,500 1, ,05 1, ,05 6,500 1, ,35 1, ,35 18" Wide Panels 1,000 2, ,90 3, ,390 3,500 2, ,90 3, ,390 6,500 2, ,90 3, ,15 1,000 4, ,800 4, ,455 3,500 4, ,680 4, ,455 6,500 4, ,305 4, ,455 1,000 2, ,545 2, ,620 3,500 2, ,545 2, ,620 6,500 2, ,225 2, ,620 1,000 3, ,365 4, ,515 3,500 3, ,230 4, ,935 6,500 3, ,805 4, ,85 1,000 2, ,060 2, ,620 3,500 2, ,20 2, ,620 6,500 2, ,615 2, ,620 1,000 3, ,465 3, ,515 3,500 3, ,320 3, ,935 6,500 3, ,825 3, ,85 1,000 1, ,15 2, ,620 3,500 1, ,045 2, ,620 6,500 1, ,930 2, ,620 1,000 2, ,555 3, ,515 3,500 2, ,380 3, ,935 6,500 2, ,825 3, ,85 1,000 1, ,430 2, ,620 3,500 1, ,320 2, ,620 6,500 1, ,190 2, ,620 1,000 2, ,555 2, ,360 3,500 2, ,380 2, ,360 6,500 2, ,825 2, ,360 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 6,500 1, ,430 1, ,620 1,000 2, ,555 2, ,295 3,500 2, ,380 2, ,295 6,500 2, ,825 2, ,295 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 6,500 1, ,430 1, ,620 1,000 2, ,080 2, ,260 3,500 2, ,080 2, ,260 6,500 2, ,825 2, ,260

14 ESR-2089 Most Widely Accepted Trusted Page 14 of 58 TABLE 1.1B Hardy Frame INSTALLATION - ON 3,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-24x8 8 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-32x / 4 24" Wide Panels 1,000 3, ,355 4, ,055 3,500 3, ,355 4, ,055 6,500 3, ,355 4, ,055 1,000 5, ,540, ,40 3,500 5, ,540, ,40 6,500 5, ,540, ,655 1,000 3, ,095 4, ,085 3,500 3, ,095 4, ,085 6,500 3, ,095 4, ,085 1,000 5, ,095 6, ,030 3,500 5, ,095 6, ,030 6,500 5, ,095 6, ,935 1,000 2, ,595 3, ,85 3,500 2, ,595 3, ,85 6,500 2, ,595 3, ,85 1,000 4, ,185 5, ,665 3,500 4, ,185 5, ,665 6,500 4, ,185 5, ,555 1,000 2, ,015 3, ,550 3,500 2, ,015 3, ,20 6,500 2, ,690 3, ,15 1,000 4, ,115 5, ,030 3,500 4, ,115 5, ,020 6,500 4, ,115 5, ,965 1,000 2, , ,620 3,500 2, ,440 3, ,620 6,500 2, ,040 3, ,620 1,000 3, ,245 4, ,00 3,500 3, ,245 4, ,00 6,500 3, ,245 4, ,985 1,000 2, ,805 2, ,620 3,500 2, ,480 2, ,620 6,500 2, ,355 2, ,620 1,000 3, ,235 4, ,00 3,500 3, ,235 4, ,00 6,500 3, ,235 4, ,985 1,000 2, ,130 2, ,620 3,500 2, ,50 2, ,620 6,500 2, ,635 2, ,620 1,000 3, ,220 4, ,00 3,500 3, ,220 4, ,00 6,500 3, ,220 4, ,985 32" Wide Brace Frames 1,000 2, ,35 2, ,10 3,500 2, ,35 2, ,335 6,500 1, ,335 1, ,335 1,000 3, ,55 3, ,55 3,500 2, ,255 2, ,255 6,500 2, ,255 2, ,255

15 ESR-2089 Most Widely Accepted Trusted Page 15 of 58 TABLE 1.1B Hardy Frame INSTALLATION - ON 3,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 32" Wide Brace Frames (Continued) 1,000 2, ,15 2, ,620 3,500 2, ,15 2, ,335 6,500 1, ,335 1, ,335 1,000 3, ,55 3, ,55 3,500 2, ,255 2, ,255 6,500 1, ,255 1, ,255 1,000 1, ,005 2, ,835 3,500 1, ,005 1, ,335 6,500 1, ,335 1, ,335 1,000 2, ,55 2, ,55 3,500 2, ,255 2, ,255 6,500 1, ,255 1, ,255 1,000 1, ,255 2, ,835 3,500 1, ,255 1, ,335 6,500 1, ,335 1, ,335 1,000 2, ,55 2, ,55 3,500 2, ,255 2, ,255 6,500 1, ,255 1, ,255 1,000 1, ,40 2, ,835 3,500 1, ,335 1, ,335 6,500 1, ,335 1, ,335 1,000 2, ,55 2, ,55 3,500 1, ,255 1, ,255 6,500 1, ,255 1, ,255 1,000 1, ,665 1, ,835 3,500 1, ,335 1, ,335 6,500 1, ,335 1, ,335 1,000 2, ,55 2, ,55 3,500 1, ,255 1, ,255 6,500 1, ,255 1, ,255 44" Wide Brace Frames 1,000 2, ,250 3, ,665 3,500 2, ,250 3, ,385 6,500 2, ,385 2, ,385 1,000 5, ,165 5, ,15 3,500 4, ,65 4, ,65 6,500 3, ,65 3, ,65 1,000 2, ,625 3, ,165 3,500 2, ,625 3, ,385 6,500 2, ,385 2, ,385 1,000 4, ,840 4, ,15 3,500 4, ,65 4, ,65 6,500 2, ,65 2, ,65 1,000 2, ,950 3, ,600 3,500 2, ,950 2, ,385 6,500 1, ,385 1, ,385 1,000 4, ,15 4, ,15 3,500 3, ,65 3, ,65 6,500 2, ,65 2, ,65

16 ESR-2089 Most Widely Accepted Trusted Page 16 of 58 TABLE 1.1B Hardy Frame INSTALLATION - ON 3,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 For SI: 1 inch = 25.4 mm, 1 lb = 4.45 N, 1 psi = 6.89 kpa. 44" Wide Brace Frames (Continued) 1,000 2, ,250 3, ,665 3,500 2, ,250 3, ,385 6,500 2, ,385 2, ,385 1,000 5, ,165 5, ,15 3,500 4, ,65 4, ,65 6,500 3, ,65 3, ,65 1,000 2, ,625 3, ,165 3,500 2, ,625 3, ,385 6,500 2, ,385 2, ,385 1,000 4, ,840 4, ,15 3,500 4, ,65 4, ,65 6,500 2, ,65 2, ,65 1,000 2, ,950 3, ,600 3,500 2, ,950 2, ,385 6,500 1, ,385 1, ,385 1,000 4, ,15 4, ,15 3,500 3, ,65 3, ,65 6,500 2, ,65 2, ,65 1,000 2, ,240 3, ,985 3,500 2, ,240 2, ,385 6,500 1, ,385 1, ,385 1,000 3, ,15 3, ,15 3,500 3, ,65 3, ,65 6,500 2, ,65 2, ,65 1,000 2, ,490 2, ,320 3,500 2, ,490 2, ,385 6,500 1, ,385 1, ,385 1,000 3, ,15 3, ,15 3,500 2, ,65 2, ,65 6,500 2, ,65 2, ,65 1,000 2, ,15 2, ,625 3,500 2, ,15 2, ,385 6,500 1, ,385 1, ,385 1,000 3, ,245 3, ,245 3,500 2, ,65 2, ,65 6,500 2, ,65 2, ,65 1 The values in this table are Stress Design (ASD) excluding a 1.33 stress increase pertain to installation directly or to nut washer with 5,000 psi minimum non-shrink grout in accordance with Section 3.. Figure 2 of this report, over normal weight concrete with minimum 3,000 psi specified compressive strength. 2 For installation on a nut washer (only) table values must be multiplied by The additional vertical axial loads are concurrent with the allowable in-plane shear load. For panels the axial load must be applied within the middle 1 / 3 of the panel width or be uniformly distributed across the entire panel width. For Brace Frame the axial load must be acting along the centerline of the post. 4 The values listed are due to overturning assume no resisting axial load. To determine anchor tension loads in panels at design shear values including the effect of axial loads, refer to Figure 4 of this report. For Brace Frames the anchor tension load equals the tabulated uplift minus P, where P is the allowable axial compression load in the Post. 5 in-plane shear drift values may be linearly interpolated for intermediate height or axial loads. 6 STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section 3..4 of this report.

17 ESR-2089 Most Widely Accepted Trusted Page 1 of 58 TABLE 1.1C Hardy Frame INSTALLATION - ON 4,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 9" Wide Panels HFX-9x / 2 1, ,425 1, ,860 2,000 HFX-9x / 4 1, ,425 1, ,860 12" Wide Panels 1,000 1, ,260 2, ,620 3,500 1, ,130 2, ,620 HFX-12x8 8 6,500 1, ,015 2, ,260 1,000 2, ,355 2, ,065 3,500 2, ,25 2, ,25 6,500 2, ,380 2, ,380 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 HFX-12x / 4 6,500 1, ,430 1, ,620 1,000 2, ,505 2, ,065 3,500 2, ,505 2, ,25 6,500 2, ,380 2, ,380 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 HFX-12x / 4 6,500 1, ,430 1, ,620 1,000 1, ,085 2, ,065 3,500 1, ,085 2, ,25 6,500 1, ,085 1, ,380 1,000 1, ,095 1, ,620 3,500 1, ,095 1, ,620 HFX-12x / 4 6,500 1, ,095 1, ,620 1,000 1, ,015 1, ,065 3,500 1, ,015 1, ,25 6,500 1, ,015 1, ,380 18" Wide Panels 1,000 2, ,0 3, ,10 3,500 2, ,0 3, ,10 HFX-18x8 8 6,500 2, ,425 3, ,845 1,000 4, ,190 4, ,645 3,500 4, ,190 4, ,645 6,500 4, ,190 4, ,645 1,000 2, ,40 3, ,620 3,500 2, ,40 3, ,620 HFX-18x / 4 6,500 2, ,035 3, ,620 1,000 3, ,995 4, ,90 3,500 3, ,995 4, ,90 6,500 3, ,995 4, ,90 1,000 2, ,90 2, ,620 3,500 2, ,595 2, ,620 HFX-18x / 4 6,500 2, ,460 2, ,620 1,000 3, ,90 4, ,865 3,500 3, ,90 4, ,865 6,500 3, ,05 4, ,865

18 ESR-2089 Most Widely Accepted Trusted Page 18 of 58 TABLE 1.1C Hardy Frame INSTALLATION - ON 4,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-24x8 8 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 18" Wide Panels (Continued) 1,000 2, ,390 2, ,620 3,500 1, ,940 2, ,620 6,500 1, ,815 2, ,620 1,000 3, ,500 3, ,00 3,500 3, ,360 3, ,00 6,500 3, ,235 3, ,980 1,000 1, ,340 2, ,620 3,500 1, ,225 2, ,620 6,500 1, ,110 2, ,620 1,000 2, ,585 2, ,585 3,500 2, ,585 2, ,585 6,500 2, ,585 2, ,585 1,000 1, ,430 2, ,620 3,500 1, ,430 2, ,620 6,500 1, ,345 2, ,620 1,000 2, ,545 2, ,545 3,500 2, ,545 2, ,545 6,500 2, ,545 2, ,545 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 6,500 1, ,430 1, ,620 1,000 2, ,415 2, ,520 3,500 2, ,415 2, ,520 6,500 2, ,415 2, ,520 24" Wide Panels 1,000 3, ,310 4, ,035 3,500 3, ,310 4, ,035 6,500 3, ,310 4, ,035 1,000 6, ,35, ,855 3,500 6, ,35, ,855 6,500 6, ,35, ,855 1,000 3, ,05 4, ,020 3,500 3, ,05 4, ,020 6,500 3, ,05 4, ,020 1,000 5, ,280, ,040 3,500 5, ,280, ,040 6,500 5, ,280, ,040 1,000 2, ,595 3, ,40 3,500 2, ,595 3, ,40 6,500 2, ,595 3, ,405 1,000 5, ,355 6, ,105 3,500 5, ,355 6, ,105 6,500 5, ,355 6, ,105 1,000 2, ,030 3, ,395 3,500 2, ,030 3, ,395 6,500 2, ,030 3, ,980 1,000 4, ,25 5, ,110 3,500 4, ,25 5, ,110 6,500 4, ,25 5, ,110

19 ESR-2089 Most Widely Accepted Trusted Page 19 of 58 TABLE 1.1C Hardy Frame INSTALLATION - ON 4,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 24" Wide Panels (Continued) 1,000 2, ,405 3, ,620 3,500 2, ,405 3, ,50 6,500 2, ,040 3, ,45 1,000 3, ,600 5, ,090 3,500 3, ,600 5, ,090 6,500 3, ,600 5, ,090 1,000 2, ,50 2, ,620 3,500 2, ,385 2, ,620 6,500 2, ,355 2, ,620 1,000 3, ,595 4, ,105 3,500 3, ,595 4, ,105 6,500 3, ,595 4, ,105 1,000 2, ,065 2, ,620 3,500 2, ,665 2, ,620 6,500 2, ,630 2, ,620 1,000 3, ,580 4, ,130 3,500 3, ,580 4, ,130 6,500 3, ,580 4, ,130 32" Wide Brace Frames 1,000 2, ,35 2, ,10 3,500 2, ,35 2, ,845 6,500 2, ,845 2, ,845 1,000 4, ,200 4, ,330 3,500 4, ,200 4, ,830 6,500 3, ,830 3, ,830 1,000 2, ,15 2, ,620 3,500 2, ,15 2, ,845 6,500 1, ,845 1, ,845 1,000 3, ,810 4, ,330 3,500 3, ,810 3, ,830 6,500 3, ,830 3, ,830 1,000 1, ,005 2, ,005 3,500 1, ,005 2, ,845 6,500 1, ,845 1, ,845 1,000 3, ,335 3, ,330 3,500 3, ,830 3, ,830 6,500 2, ,830 2, ,830 1,000 1, ,255 2, ,340 3,500 1, ,255 2, ,845 6,500 1, ,845 1, ,845 1,000 2, ,235 3, ,330 3,500 2, ,235 3, ,830 6,500 2, ,830 2, ,830 1,000 1, ,40 2, ,630 3,500 1, ,40 1, ,845 6,500 1, ,845 1, ,845 1,000 2, ,225 2, ,860 3,500 2, ,225 2, ,830 6,500 2, ,830 2, ,830

20 ESR-2089 Most Widely Accepted Trusted Page 20 of 58 TABLE 1.1C Hardy Frame INSTALLATION - ON 4,000 PSI COMPRESSIVE STRENGTH CONCRETE 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-32x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 32" Wide Brace Frames (Continued) 1,000 1, ,665 2, ,885 3,500 1, ,665 1, ,845 6,500 1, ,845 1, ,845 1,000 2, ,325 2, ,325 3,500 2, ,325 2, ,325 6,500 2, ,830 2, ,830 44" Wide Brace Frames 1,000 2, ,250 3, ,665 3,500 2, ,250 3, ,665 6,500 2, ,250 2, ,655 1,000 5, ,165 6, ,550 3,500 5, ,165 6, ,530 6,500 5, ,165 5, ,530 1,000 2, ,625 3, ,165 3,500 2, ,625 3, ,165 6,500 2, ,625 2, ,655 1,000 4, ,840 6, ,455 3,500 4, ,840 5, ,530 6,500 4, ,530 4, ,530 1,000 2, ,950 3, ,600 3,500 2, ,950 3, ,600 6,500 2, ,655 2, ,655 1,000 4, ,430 5, ,030 3,500 4, ,430 5, ,530 6,500 4, ,530 4, ,530 1,000 2, ,240 3, ,985 3,500 2, ,240 2, ,655 6,500 2, ,655 2, ,655 1,000 4, ,905 4, ,490 3,500 4, ,905 4, ,530 6,500 3, ,530 3, ,530 1,000 2, ,490 2, ,320 3,500 2, ,490 2, ,655 6,500 1, ,655 1, ,655 1,000 3, ,910 3, ,515 3,500 3, ,910 3, ,515 6,500 3, ,530 3, ,530 1,000 2, ,15 2, ,625 3,500 2, ,15 2, ,655 6,500 1, ,655 1, ,655 1,000 3, ,245 3, ,245 3,500 3, ,245 3, ,245 6,500 3, ,245 3, ,245 For SI: 1 inch = 25.4 mm, 1 foot = mm, 1 lb = 4.45 N, 1 psi = 6.89 kpa. 1 The values in this table are Stress Design (ASD) excluding a 1.33 stress increase pertain to installation directly or to nut washer with 5,000 psi minimum non-shrink grout in accordance with Section 3.. Figure 2 of this report, over normal weight concrete with minimum 4,000 psi specified compressive strength. 2 For installation on a nut washer (only) table values must be multiplied by The additional vertical axial loads are concurrent with the allowable in-plane shear load. For panels the axial load must be applied within the middle 1 / 3 of the panel width or be uniformly distributed across the entire panel width. For Brace Frame the axial load must be acting along the centerline of the post.

21 ESR-2089 Most Widely Accepted Trusted Page 21 of 58 Notes to TABLE 1.1C (Continued): 4 The values listed are due to overturning assume no resisting axial load. To determine anchor tension loads in panels at design shear values including the effect of axial loads, refer to Figure 4 of this report. For Brace Frames the anchor tension load equals the tabulated uplift minus P, where P is the allowable axial compression load in the Post. 5 in-plane shear drift values may be linearly interpolated for intermediate height or axial loads. 6 STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section 3..4 of this report. TABLE 1.2A Hardy Frame INSTALLATION - ON RAISED FLOORS 1,2 Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-12x8 8 HFX-12x / 4 HFX-12x / 4 HFX-12x / 4 HFX-18x8 8 HFX-18x / 4 HFX-18x / 4 12" Wide Panels 1,000 1, ,165 1, ,585 3,500 1, ,625 1, ,20 6,500 1, ,5 1, ,610 1,000 1, ,150 1, ,565 3,500 1, ,610 1, ,05 6,500 1, ,60 1, ,610 1,000 1, ,305 1, ,690 3,500 1, ,60 1, ,820 6,500 1, ,910 1, ,610 1,000 1, ,20 1, ,60 3,500 1, ,25 1, ,805 6,500 1, ,85 1, ,610 1,000 1, ,395 1, ,0 3,500 1, ,850 1, ,900 6,500 1, ,995 1, ,610 1,000 1, ,360 1, ,45 3,500 1, ,815 1, ,85 6, ,960 1, ,610 1, ,45 1, ,835 3, ,925 1, ,965 6, , ,610 1, ,445 1, ,810 3, ,900 1, ,940 6, , ,610 18" Wide Panels 1,000 2, ,935 3, ,100 3,500 2, ,055 3, ,610 6,500 2, ,610 2, ,610 1,000 2, ,925 3, ,00 3,500 2, ,045 3, ,610 6,500 2, ,610 2, ,610 1,000 2, ,055 2, ,230 3,500 2, ,10 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,025 2, ,10 3,500 2, ,140 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,100 2, ,285 3,500 2, ,215 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,090 2, ,250 3,500 2, ,200 2, ,610 6,500 1, ,610 1, ,610

22 ESR-2089 Most Widely Accepted Trusted Page 22 of 58 TABLE 1.2A Hardy Frame INSTALLATION - ON RAISED FLOORS 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-24x8 8 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 18" Wide Panels (Continued) 1,000 1, ,190 2, ,380 3,500 1, ,300 2, ,610 6,500 1, ,610 1, ,610 1,000 1, ,145 2, ,330 3,500 1, ,260 2, ,610 6,500 1, ,610 1, ,610 1,000 1, ,240 2, ,35 3,500 1, ,345 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,225 2, ,420 3,500 1, ,330 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,295 1, ,505 3,500 1, ,400 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,20 1, ,45 3,500 1, ,35 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,360 1, ,580 3,500 1, ,465 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,320 1, ,540 3,500 1, ,425 1, ,610 6,500 1, ,610 1, ,610 24" Wide Panels 1,000 3, ,00 5, ,0 3,500 3, ,395 4, ,610 6,500 3, ,610 3, ,610 1,000 5, ,620 5, ,610 3,500 4, ,610 4, ,610 6,500 3, ,610 3, ,610 1,000 3, ,555 4, ,610 3,500 3, ,250 3, ,610 6,500 2, ,610 2, ,610 1,000 4, ,0 4, ,610 3,500 3, ,610 3, ,610 6,500 2, ,610 2, ,610 1,000 3, ,160 3, ,610 3,500 3, ,850 3, ,610 6,500 2, ,610 2, ,610 1,000 3, ,855 3, ,610 3,500 3, ,610 3, ,610 6,500 2, ,610 2, ,610 1,000 2, ,655 3, ,610 3,500 2, ,350 2, ,610 6,500 2, ,610 2, ,610 1,000 3, ,910 3, ,610 3,500 2, ,610 2, ,610 6,500 2, ,610 2, ,610

23 ESR-2089 Most Widely Accepted Trusted Page 23 of 58 TABLE 1.2A Hardy Frame INSTALLATION - ON RAISED FLOORS 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 24" Wide Panels (Continued) 1,000 2, ,090 3, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 3, ,00 3, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,450 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,130 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,85 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,180 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 32" Wide Brace Frames 1,000 2, ,040 2, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 2, ,040 2, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540

24 ESR-2089 Most Widely Accepted Trusted Page 24 of 58 TABLE 1.2A Hardy Frame INSTALLATION - ON RAISED FLOORS 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3,5 HFX-32x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 32" Wide Brace Frames (Continued) 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540 44" Wide Brace Frames For SI: 1 inch = 25.4 mm, 1 foot = mm, 1 lb = 4.45 N, 1 psi = 6.89 kpa. 1,000 2, ,610 3, ,295 3,500 2, ,95 2, ,95 6,500 1, ,95 1, ,95 1,000 3, ,295 3, ,295 3,500 2, ,95 2, ,95 6,500 1, ,95 1, ,95 1,000 2, ,005 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6, , ,95 1 The values in this table are Stress Design (ASD) excluding a 1.33 stress increase pertain to installation on Raised Floor Systems that bear on concrete or masonry foundations. 2 Raised Floor System for panels assumes 2-by wood sill plate, Engineered Wood Product (EWP) rim board up to 12 inches deep with F c = 680 psi with a Hardy Frame Bearing Plate installed below the panel. For EWP rim boards up to 18 inches deep, the allowable shear value must be multiplied by 0.96 for 12-inch-wide panels by 0.98 for inch panels. For all panels, the corresponding drift is unchanged. Raised Floor System for Brace Frames assumes 2-by wood sill plate with F c = 625 psi. Engineered Wood Product rim board up to 12 inches deep with F c = 680 psi, floor sheathing a 2-by wood bottom plate below the Brace Frame. For EWP rim boards up to 18 inches deep, the allowable shear value does not change the corresponding drift must be multiplied by 1.03.

25 ESR-2089 Most Widely Accepted Trusted Page 25 of 58 Notes to TABLE 1.2A (Continued): 3 The additional vertical axial loads are concurrent with the allowable in-plane shear load. For panels the axial load must be applied within the middle 1 / 3 of the panel width or be uniformly distributed across the entire panel width. For Brace Frame the axial load is acting along the centerline of the end post. 4 The values listed are due to overturning assume no resisting axial load. To determine the anchor tension load in panels at design shear values including the effect of axial loads, the tension load equals uplift minus P/2, where P is the axial load on the panel. For Brace Frames the anchor tension load equals the tabulated uplift minus P where P is the allowable axial compression load on the end post. 5 shear drift values may be linearly interpolated for intermediate height or axial loads. 6 STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section 3..4 of this report. TABLE 1.3A Hardy Frame INSTALLATION - ON UPPER FLOORS 1,2 Net Height H HD Bolt Dia Grade 6 Axial Load 3, Shear V, HFX-12x8 8 HFX-12x / 4 HFX-12x / 4 HFX-12x / 4 HFX-18x8 8 HFX-18x / 4 12" Wide Panels 1,000 1, ,940 1, ,05 3,500 1, ,350 1, ,485 6,500 1, ,440 1, ,610 1,000 1, ,930 1, ,055 3,500 1, ,340 1, ,460 6,500 1, ,425 1, ,610 1,000 1, ,060 1, ,205 3,500 1, ,460 1, ,610 6, ,545 1, ,610 1,000 1, ,030 1, ,180 3,500 1, ,435 1, ,585 6, ,520 1, ,610 1, ,135 1, ,305 3, ,535 1, ,05 6, ,615 1, ,610 1, ,105 1, ,25 3, ,505 1, ,65 6, ,590 1, ,610 1, ,195 1, ,390 3, ,595 1, ,90 6, , ,610 1, ,10 1, ,360 3, ,50 1, ,60 6, , ,610 18" Wide Panels 1,000 2, ,25 3, ,920 3,500 2, ,040 3, ,610 6,500 2, ,610 2, ,610 1,000 2, ,15 3, ,890 3,500 2, ,035 3, ,610 6,500 2, ,610 2, ,610 1,000 2, ,85 2, ,030 3,500 2, ,145 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,835 2, ,980 3,500 2, ,120 2, ,610 6,500 1, ,610 1, ,610

26 ESR-2089 Most Widely Accepted Trusted Page 26 of 58 TABLE 1.3A Hardy Frame INSTALLATION - ON UPPER FLOORS 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3, Shear V, HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-18x / 4 HFX-24x8 8 HFX-24x / 4 18" Wide Panels (Continued) 1,000 2, ,930 2, ,080 3,500 1, ,185 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,915 2, ,050 3,500 1, ,10 2, ,610 6,500 1, ,610 1, ,610 1,000 1, ,040 2, ,165 3,500 1, ,255 2, ,610 6,500 1, ,610 1, ,610 1,000 1, ,985 2, ,120 3,500 1, ,220 2, ,610 6,500 1, ,610 1, ,610 1,000 1, ,100 1, ,160 3,500 1, ,300 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,080 1, ,200 3,500 1, ,285 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,165 1, ,25 3,500 1, ,350 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,135 1, ,245 3,500 1, ,325 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,250 1, ,340 3,500 1, ,400 1, ,610 6,500 1, ,610 1, ,610 1,000 1, ,200 1, ,305 3,500 1, ,30 1, ,610 6,500 1, ,610 1, ,610 24" Wide Panels 1,000 3, ,00 5, ,0 3,500 3, ,395 4, ,610 6,500 3, ,610 3, ,610 1,000 4, ,420 5, ,610 3,500 4, ,610 4, ,610 6,500 3, ,610 3, ,610 1,000 3, ,555 4, ,610 3,500 3, ,250 3, ,610 6,500 2, ,610 2, ,610 1,000 4, ,555 4, ,610 3,500 3, ,610 3, ,610 6,500 2, ,610 2, ,610

27 ESR-2089 Most Widely Accepted Trusted Page 2 of 58 TABLE 1.3A Hardy Frame INSTALLATION - ON UPPER FLOORS 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3, Shear V, HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-24x / 4 HFX-32x / 4 HFX-32x / 4 24" Wide Panels (Continued) 1,000 3, ,160 3, ,610 3,500 3, ,850 3, ,610 6,500 2, ,610 2, ,610 1,000 3, ,625 3, ,610 3,500 3, ,610 3, ,610 6,500 2, ,610 2, ,610 1,000 2, ,655 3, ,610 3,500 2, ,350 2, ,610 6,500 2, ,610 2, ,610 1,000 3, ,680 3, ,610 3,500 2, ,610 2, ,610 6,500 2, ,610 2, ,610 1,000 2, ,090 3, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,815 3, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,450 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,80 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,85 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 1,000 2, ,915 2, ,610 3,500 2, ,610 2, ,610 6,500 1, ,610 1, ,610 32" Wide Brace Frames 1,000 2, ,040 2, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 2, ,040 2, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540

28 ESR-2089 Most Widely Accepted Trusted Page 28 of 58 TABLE 1.3A Hardy Frame INSTALLATION - ON UPPER FLOORS 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3, Shear V, HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-32x / 4 HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 32" Wide Brace Frames (Continued) 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3,500 1, ,540 1, ,540 6, , ,540 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540 1,000 1, ,040 1, ,040 3, , ,540 6, , ,540 44" Wide Brace Frames 1,000 2, ,610 3, ,295 3,500 2, ,95 2, ,95 6,500 1, ,95 1, ,95 1,000 3, ,295 3, ,295 3,500 2, ,95 2, ,95 6,500 1, ,95 1, ,95 1,000 2, ,005 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95

29 ESR-2089 Most Widely Accepted Trusted Page 29 of 58 TABLE 1.3A Hardy Frame INSTALLATION - ON UPPER FLOORS 1,2 (Continued) Net Height H HD Bolt Dia Grade 6 Axial Load 3, Shear V, HFX-44x / 4 HFX-44x / 4 HFX-44x / 4 44" Wide Brace Frames (Continued) For SI: 1 inch = 25.4 mm, 1 foot = mm, 1 lb = 4.45 N, 1 psi = 6.89 kpa. 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6, , ,95 1 The values in this table are Stress Design (ASD) excluding a 1.33 stress increase pertain to installation on Upper Floor Systems that bear on wood frame walls below. 2 Upper Floor System for panels assumes double 2-by wood plates in the wall below, Engineered Wood Product (EWP) rim board up to 12 inches deep with F c = 680 psi with a Hardy Frame Bearing Plate installed below the panel. For EWP rim boards up to 18 inches deep, the allowable shear value must be multiplied by 0.96 for 12-inch-wide panels by 0.98 for inch panels. For all panels, the corresponding drift is unchanged. Upper Floor System for Brace Frames assumes double 2-by wood plates in the wall below, Engineered Wood Product rim board up to 12 inches deep with F c = 680 psi, floor sheathing a 2-by wood bottom plate with F c = 625 psi below the Brace Frames. For EWP rim boards up to 18 inches deep, the allowable shear value does not change the corresponding drift must be multiplied by The additional vertical axial loads are concurrent with the allowable shear load. For panels the axial load must be applied within the middle 1 / 3 of the panel width or be uniformly distributed across the entire panel width. For Brace Frame the axial load is acting along the centerline of the end post. 4 The values listed are due to overturning assume no resisting axial load. To determine the anchor tension load in panels at design shear values including the effect of axial loads, the tension load equals uplift minus P/2, where P is the axial load on the panel. For Brace Frames the anchor tension load equals uplift minus P where P is the axial load on the end post. 5 shear drift values may be linearly interpolated for intermediate height or axial loads. 6 STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section 3..4 of this report. Refer to Section of this report for additional drift due to support (beam) deflection.

30 ESR-2089 Most Widely Accepted Trusted Page 30 of 58 TABLE 2.1A Hardy Frame HFX/S INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1 Net Height H HD Bolt Dia Grade 5 Axial Load 2 Shear V 4 at V 3,4 Shear V 4 at V 3 9" Wide Panels HFX/S-9x / 8 2, , ,460 12" Wide Panels 1,000 1, ,425 1, ,595 3,500 1, ,005 1, ,005 HFX/S-12x / 8 6,500 1, ,320 1, ,320 1,000 1, ,595 1, ,595 3,500 1, ,005 1, ,005 6,500 1, ,320 1, ,320 1,000 1, ,425 1, ,595 3,500 1, ,005 1, ,005 HFX/S-12x / 8 6,500 1, ,325 1, ,325 1,000 1, ,595 1, ,595 3,500 1, ,005 1, ,005 6,500 1, ,325 1, ,325 1,000 1, ,425 1, ,595 3,500 1, ,005 1, ,005 HFX/S-12x / 8 6, , ,325 1,000 1, ,595 1, ,595 3,500 1, ,005 1, ,005 6, , ,325 18" Wide Panels 1,000 2, ,805 2, ,620 3,500 2, ,530 2, ,620 HFX/S-18x / 8 6,500 2, ,190 2, ,620 1,000 3, ,030 3, ,015 3,500 3, ,260 3, ,00 6,500 3, ,305 3, ,45 1,000 1, ,965 2, ,620 3,500 1, ,80 2, ,620 HFX/S-18x / 8 6,500 1, ,190 2, ,620 1,000 2, ,030 3, ,015 3,500 2, ,260 3, ,00 6,500 2, ,385 2, ,45 1,000 1, ,250 2, ,620 3,500 1, ,150 2, ,620 HFX/S-18x / 8 6,500 1, ,190 2, ,620 1,000 2, ,030 2, ,015 3,500 2, ,260 2, ,00 6,500 2, ,430 2, ,45 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 HFX/S-18x / 8 6,500 1, ,190 1, ,620 1,000 2, ,030 2, ,015 3,500 2, ,260 2, ,00 6,500 2, ,430 2, ,45 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 HFX/S-18x / 8 6,500 1, ,190 1, ,620 1,000 2, ,030 2, ,015 3,500 2, ,260 2, ,00 6,500 2, ,430 2, ,45

31 ESR-2089 Most Widely Accepted Trusted Page 31 of 58 TABLE 2.1A Hardy Frame HFX/S INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1 (Continued) Net Height H HD Bolt Dia Grade 5 Axial Load 2 Shear V 4 at V 3,4 Shear V 4 at V 3 HFX/S-18x / 8 HFX/S-24x / 8 HFX/S-24x / 8 HFX/S-24x / 8 HFX/S-24x / 8 HFX/S-24x / 8 HFX/S-24x / 8 18" Wide Panels (Continued) 1,000 1, ,430 1, ,620 3,500 1, ,430 1, ,620 6,500 1, ,190 1, ,620 1,000 2, ,030 2, ,015 3,500 1, ,260 2, ,00 6,500 1, ,260 1, ,45 24" Wide Panels 1,000 2, ,200 3, ,490 3,500 2, ,200 3, ,490 6,500 2, ,200 3, ,490 1,000 4, ,600 5, ,185 3,500 4, ,600 5, ,00 6,500 4, ,600 5, ,880 1,000 2, ,45 3, ,250 3,500 2, ,45 3, ,250 6,500 2, ,45 3, ,020 1,000 4, ,60 5, ,865 3,500 4, ,60 5, ,180 6,500 4, ,60 5, ,055 1,000 2, ,215 3, ,620 3,500 2, ,215 3, ,610 6,500 2, ,940 3, ,515 1,000 4, ,595 4, ,865 3,500 4, ,595 4, ,180 6,500 4, ,595 4, ,055 1,000 2, ,620 2, ,620 3,500 2, ,620 2, ,620 6,500 2, ,280 2, ,620 1,000 3, ,420 4, ,865 3,500 3, ,420 4, ,180 6,500 3, ,420 4, ,055 1,000 2, ,95 2, ,620 3,500 2, ,655 2, ,620 6,500 2, ,560 2, ,620 1,000 3, ,285 4, ,865 3,500 3, ,285 4, ,180 6,500 3, ,285 3, ,055 1,000 2, ,290 2, ,620 3,500 2, ,905 2, ,620 6,500 1, ,805 2, ,620 1,000 3, ,160 3, ,865 3,500 3, ,160 3, ,180 6,500 3, ,160 3, ,055

32 ESR-2089 Most Widely Accepted Trusted Page 32 of 58 TABLE 2.1A Hardy Frame HFX/S INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1 (Continued) Net Height H HD Bolt Dia Grade 5 Axial Load 2 Shear V 4 at V 3,4 Shear V 4 at V 3 HFX/S-32x / 8 HFX/S-32x / 8 HFX/S-32x / 8 HFX/S-32x / 8 HFX/S-32x / 8 HFX/S-32x / 8 HFX/S-44x / 8 HFX/S-44x / 8 32" Wide Brace Frames 1,000 2, ,505 2, ,630 3,500 2, ,130 2, ,130 6,500 1, ,130 1, ,130 1,000 2, ,295 2, ,295 3,500 2, ,95 2, ,95 6,500 1, ,95 1, ,95 1,000 1, ,825 2, ,630 3,500 1, ,130 1, ,130 6,500 1, ,130 1, ,130 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6,500 1, ,95 1, ,95 1,000 1, ,100 2, ,630 3,500 1, ,130 1, ,130 6,500 1, ,130 1, ,130 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6,500 1, ,95 1, ,95 1,000 1, ,335 1, ,630 3,500 1, ,130 1, ,130 6, , ,130 1,000 2, ,295 2, ,295 3,500 1, ,95 1, ,95 6,500 1, ,95 1, ,95 1,000 1, ,545 1, ,630 3,500 1, ,130 1, ,130 6, , ,130 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6, , ,95 1,000 1, ,30 1, ,630 3,500 1, ,130 1, ,130 6, , ,130 1,000 1, ,295 1, ,295 3,500 1, ,95 1, ,95 6, , ,95 44" Wide Brace Frames 1,000 2, ,395 3, ,860 3,500 2, ,395 3, ,365 6,500 1, ,365 1, ,365 1,000 4, ,645 4, ,645 3,500 3, ,145 3, ,145 6,500 2, ,145 2, ,145 1,000 2, ,50 3, ,330 3,500 2, ,50 2, ,365 6,500 1, ,365 1, ,365 1,000 3, ,645 3, ,645 3,500 3, ,145 3, ,145 6,500 2, ,145 2, ,145

33 ESR-2089 Most Widely Accepted Trusted Page 33 of 58 TABLE 2.1A Hardy Frame HFX/S INSTALLATION - ON 2,500 PSI COMPRESSIVE STRENGTH CONCRETE 1 (Continued) Net Height H HD Bolt Dia Grade 5 Axial Load 2 Shear V 4 at V 3,4 Shear V 4 at V 3 HFX/S-44x / 8 HFX/S-44x / 8 HFX/S-44x / 8 HFX/S-44x / 8 44" Wide Brace Frames (Continued) For SI: 1 inch = 25.4 mm, 1 foot = mm, 1 lb = 4.45 N, 1 psi = 6.89 kpa. 1,000 2, ,060 3, ,45 3,500 2, ,060 2, ,365 6,500 1, ,365 1, ,365 1,000 3, ,645 3, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145 1,000 2, ,335 2, ,865 3,500 2, ,335 2, ,365 6,500 1, ,365 1, ,365 1,000 3, ,645 3, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145 1,000 2, ,55 2, ,865 3,500 2, ,365 2, ,365 6,500 1, ,365 1, ,365 1,000 2, ,645 2, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145 1,000 2, ,95 2, ,865 3,500 1, ,365 1, ,365 6,500 1, ,365 1, ,365 1,000 2, ,645 2, ,645 3,500 2, ,145 2, ,145 6,500 1, ,145 1, ,145 1 The values in this table are Stress Design (ASD) excluding a 1.33 stress increase pertain to installation, directly or to nut washer with 5,000 psi minimum compressive strength non-shrink grout in accordance with Section 3.. Figure 2 of this report over normal weight concrete, with a minimum 2,500 psi compressive strength. 2 The additional vertical axial loads are concurrent with the allowable in-plane shear load. For panels the axial load must be applied within the middle 1 / 3 of the panel width or be uniformly distributed across the entire panel width. For Brace Frame the axial load must be acting along the centerline of the post. 3 The values listed are due to overturning assume no resisting axial load. To determine anchor tension loads in panels at design shear values including the effect of axial loads, refer to Figure 4 of this report. For Brace Frames the anchor tension load equals the tabulated uplift minus P, where P is the allowable axial compression load in the Post. 4 in-plane shear drift values may be linearly interpolated for intermediate height or axial loads. 5 STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section 3..4 of this report.

34 ESR-2089 Most Widely Accepted Trusted Page 34 of 58 TABLE 3.1A Hardy Frame PANELS IN BALLOON WALL APPLICATIONS INSTALLATION ON CONCRETE 1,2 Net Height H HD Bolt Dia Grade 5 Concrete Compressive Strength at V 3,4,3 Axial Load 3 HFX- 18x14 HFX- 18x15 HFX- 18x16 HFX- 18x1 HFX- 18x18 HFX- 18x19 HFX- 18x20 HFX- 24x14 HFX- 24x15 HFX- 24x16 HFX- 24x1 HFX- 24x24 HFX- 24x19 HFX- 24x / / / / / / / / / / / / / / 4 For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 18" Wide Panels 2,500 18,43 32,453 3,000 1, ,54 1, ,168 4,000 16,632 25,320 2,500 18,93 32,593 3,000 1, ,953 1, ,251 4,000 16,989 25,382 2,500 19,433 32,654 3,000 1, ,383 1, ,28 4,000 1,365 25,409 2,500 19,888 32,81 3,000 1, ,5 1, ,362 4,000 1,06 25,465 2,500 20,445 33,092 3,000 1, ,252 1, ,543 4,000 18,118 25,598 2,500 20,885 33,191 3,000 1, ,625 1, ,600 4,000 18,440 25,640 2,500 21,489 26,31 3,000 1, ,134 1, ,988 4,000 18,86 22,06 24" Wide Panels 2,500 18,855 33,15 3,000 2, ,240 3, ,680 4,000 1,59 28,506 2,500 19,000 30,88 3,000 1, ,33 2, ,52 4,000 1,01 26,888 2,500 18,84 31,139 3,000 1, , ,041 4,000 1,594 2,132 2,500 18,600 30,683 3,000 1, ,003 2, ,664 4,000 1,361 26,814 2,500 18,541 30,503 3,000 1, ,949 2, ,515 4,000 1,311 26,68 2,500 18,620 30,02 3,000 1, , ,680 4,000 1,38 26,82 2,500 18,965 31,192 3,000 1, ,341 2, ,085 4,000 1,61 2,10 1 The values in this table are Stress Design (ASD) excluding a 1.33 stress increase pertain to installation directly or to nut washer with 5,000 psi minimum non-shrink grout in accordance with Section 3.. Figure 2 of this report, over normal weight concrete with the minimum tabulated compressive strength. 2 For installation on a nut washer (only) table values must be multiplied by The additional vertical axial loads are concurrent with the allowable in-plane shear load. The axial load must be applied within the middle 1 / 3 of the panel width or be uniformly distributed across the entire panel width. 4 The uplift values listed are due to overturning assume no resisting axial load. To determine anchor tension loads in panels at design shear values including the effect of axial loads, refer to Figure 4 of this report. 5 in-plane shear drift values may be linearly interpolated for Panels of the same width with either intermediate height or axial loads. 6 HS indicates bolts complying with a high strength steel specification as set forth in Section 3..4 of this report. 4,000 3,500 3,000 2,500 2,000 2,000 2,000 4,000 3,500 3,000 2,500 2,000 2,000 2,000

35 ESR-2089 Most Widely Accepted Trusted Page 35 of 58 TABLE 4.0 Hardy Frame PANEL AND BRACE FRAME OUT-OF PLANE DESIGN LOADS Hardy Frame Product Width Out-of-Plane Load (psf) 1,2,3 Nominal Height (H) of Panel or Brace Frame (ft) 8 (inches) HFX 9 inch Panels n/a n/a n/a n/a n/a HFX 12 inch Panels n/a n/a n/a HFX 18 inch Panels HFX 24 inch Panels HFX 32 inch Brace Frame n/a HFX 44 inch Brace Frame n/a For SI: 1 inch = 25.4 mm, 1 foot = mm, 1 psi = 6.89 kpa. 1 wind loads are limited to H/240 deflection for walls with flexible finishes using the 0. factor on the wind load in accordance with footnote f, Table of the 2006 IBC. For other conditions, the tabulated value must be multiplied by The connection at top bottom of panels Brace Frames to the structural supports must be designed detailed for the design loads by the Building Design Professional. 3 Loads shown are Stress Design (ASD) exclude a 1.33 stress increase. 4 For panels in balloon wall applications, out-of-plane loads must be resisted by other framing members, which must be designed detailed by the building design professional. 5 For foot nominal wall heights, 9 inch panels are 9 1 / 2 inches net, height, all other panel widths are 8 inches net height. TABLE 5.1 Hardy Frame POST 1 Net Height Hold Down Diameter Compression 2,3,4 STD Tension 5 HS Tension 5 HFP-Series / 8 HFP8- / / 4 13,500 2,100 26,645 HFP8-1 1 / / / 8 22,400 36,100 / 8 HFP9- / / 4 13,500 2,100 24,10 HFP9-1 1 / / / 8 22,400 36,100 / 8 HFP10- / / 4 13,500 2,100 21,255 HFP / / / 8 22,400 36,100 / 8 HFP11- / / 4 13,500 2,100 18,65 HFP / / / 8 22,400 36,100 / 8 HFP12- / / 4 13,500 2,100 16,645 HFP / / / 8 22,400 36,100 / 8 HFP13- / / 4 13,500 2,100 14,090 HFP / / / 8 22,400 36,100 / 8 HFP/S-Series HFP/S8- / / 8 13,500 2,100 25,45 HFP/S8-1 1 / / / 8 22,400 36,100 / 8 HFP/S9- / / 8 13,500 2,100 23,105 HFP/S9-1 1 / / / 8 22,400 36,100 / 8 HFP/S10- / / 8 13,500 2,100 20,350 HFP/S / / / 8 22,400 36,100 / 8 HFP/S11- / / 8 13,500 2,100 1,990 HFP/S / / / 8 22,400 36,100 / 8 HFP/S12- / / 8 13,500 2,100 15,15 HFP/S / / / 8 22,400 36,100 / 8 HFP/S13- / / 8 13,500 2,100 13,160 HFP/S / / / 8 22,400 36,100 For SI: 1 inch = 25.4 mm, 1 = 4.45 N, 1 psi = 6.89 kpa.

36 ESR-2089 Most Widely Accepted Trusted Page 36 of 58 Notes to TABLE 5.1 (Continued): 1 The values in this table are Stress Design (ASD), exclude a 1.33 stress increase, assume installations directly on a rigid base, or a nut washer with non-shrink grout of 5,000 psi minimum compressive strength over a rigid base, in accordance with Section of this report. 2 The maximum allowable compression of the post must be further limited as follows: a. Wood with 625 psi allowable compression perpendicular to grain =,656 lbs. b. Wood with 680 psi allowable compression perpendicular to grain = 8,330 lbs. c. Normal weight concrete with f c = 2,500 psi = 10,412 pounds. d. Normal weight concrete with f c = 3,000 psi = 12,495 pounds. e. Normal weight concrete with f c = 4,000 psi = 16,660 pounds. 3 For installation on supporting materials other than noted in footnote 2, the Building Design Professional must check the Bearing Stresses based on the Post bearing area of square inches; 4 For compression loads exceeding the allowable bearing stress of the supporting material the Building Design Professional is permitted to design bearing plates to increase the bearing area in order to reduce the bearing stress. 5 STD indicates bolts complying with ASTM F 1554 Grade 36. HS indicates bolts complying with a high strength steel specification as set forth in Section of this report. TABLE 6.1 Hardy Frame SADDLE 1,3,4, Fastener Qty 2 Tension 5,6 Compression HFS d Common 2,950 2,500 HFS d Common 4,280 2,500 For SI: 1 inch = 25.4 mm, 1 foot = mm, 1 lb = 4.45 N. 1 The maximum notched section in the wood member is 4-1/2 inches as shown in Figure 2, Detail SA 1 of this report. 2 Fastener quantity is the number of 16d Common nails to be installed into each of the members to be joined. Table 6.2 of this report provides factors for reducing tabulated loads where other nail styles are used. 3 When the end distance from the joint to the first nail hole is less than 1-inch, omit the (2) nails in the 3-inch side-plate the (1) nail in the 1-1/2 inch side-plate that are nearest the joint must be omitted. 4 For the condition described in footnote 3, there is no reduction in values provided the HFS24 is installed with minimum 22-16d Common nails in each member being joined (44 total) the HFS36 is installed with 31-16d Common nails in each member (62 total). 5 The allowable tension capacities are for normal load duration. The values may be adjusted for other load durations, such as for seismic wind loading in accordance with the AF&PA NDS. 6 tension capacities assume the Saddle is attached to lumber members with a specific gravity of 0.49 or higher Loads shown are Stress Design (ASD) exclude a 1.33 stress increase. TABLE 6.2 Hardy Frame SADDLE ALTERNATIVE FASTENERS Table Nail Type Replacement Nail Description D x L Use Percentage of Load 16d Common 16d Box x 3 1 / d Common N10 x 1.5 No. 9 ga x 1 1 / d Common N16 x 2.5 No. 8 ga x 2 1 / d Common 16d Sinker x 3 1 / d Common 10d Common x d Common 12d Common x 3 1 / For SI: 1 inch = 25.4 mm.

37 ESR-2089 Most Widely Accepted Trusted Page 3 of 58

38 ESR-2089 Most Widely Accepted Trusted Page 38 of 58

39 ESR-2089 Most Widely Accepted Trusted Page 39 of 58

40 ESR-2089 Most Widely Accepted Trusted Page 40 of 58 NOTE: COUPLING NUTS COMPLYING WITH SECTION 3..5 MAY BE USED NOTE: COUPLING NUTS COMPLYING WITH SECTION 3..5 MAY BE USED

41 ESR-2089 Most Widely Accepted Trusted Page 41 of 58

42 ESR-2089 Most Widely Accepted Trusted Page 42 of 58

43 ESR-2089 Most Widely Accepted Trusted Page 43 of 58

44 ESR-2089 Most Widely Accepted Trusted Page 44 of 58

45 ESR-2089 Most Widely Accepted Trusted Page 45 of 58

46 ESR-2089 Most Widely Accepted Trusted Page 46 of 58 NOTE: COUPLING NUTS COMPLYING WITH SECTION 3..5 MAY BE USED NOTE: COUPLING NUTS COMPLYING WITH SECTION 3..5 MAY BE USED

47 ESR-2089 Most Widely Accepted Trusted Page 4 of 58

48 ESR-2089 Most Widely Accepted Trusted Page 48 of 58

49 ESR-2089 Most Widely Accepted Trusted Page 49 of 58

50 ESR-2089 Most Widely Accepted Trusted Page 50 of 58 Hardy Frame PANELS: IBC ANCHORAGE FOR 1 1 / 8 -INCH DIAMETER ANCHORS (A B =0.994 in 2 ) 1,4,8 Concrete Compressive Strength 2,500 psi 3,000 psi 4,000 psi Design Load 2 Concrete Condition at Service Load Anchorage Call-Out 3 5 T ASD l e 6 C a1 & C a2 l e 6 C a1 & C a2 l e 6 C a1 & C a2 Cracked Uncracked Cracked Uncracked STD-SA 21, STD-SB 1, HS-SA 46, HS-SB 32, HS-SC 30, HS-SD 25, HS-SE 20, Balloon-SA 21, STD-SC 21, STD-SD 1, HS-SF 46, HS-SG 32, HS-SH 30, HS-SI 25, HS-SJ 20, Balloon-SB 21, STD-WA 21, HS-WA 46, HS-WB 40, HS-WC 20, Balloon-WA 32, Balloon-WB 33, STD-WB 21, HS-WD 46, HS-WE 40, HS-WF 20, Balloon-WC 32, Balloon-WD 33, For SI: 1 inch = 25.4 mm, 1 in 2 = 645 mm 2, 1 lbf = 4.45 N. 1 Anchorage design complies with ACI 318 Appendix D Condition B with no supplemental reinforcement for cracked uncracked normal weight concrete with the tabulated minimum specified compressive strength. Cracked concrete occurs where analysis indicates cracking (f t > f r ) at service load levels. 2 In Design Categories (SDC) A B for detached 1 2 family dwellings in SDC A, B, C, wind values apply. 3 STD indicates steel anchor bolts complying with ASTM F 1554 Grade 36. HS indicates steel anchor rods complying with a high strength steel specification as set forth in Section 3..4 of this Report. 4 A b is the nominal cross sectional area of the Hold down Anchor. 5 T ASD is the Stress Design tension load. 6 l e is the embedment depth into a foundation that provides the minimum edge end distance requirements C a1 C a2. C a1 is the minimum end distance C a2 is the minimum edge distance to the centerline of the Hold down Anchor. 8 Foundation dimensions consider anchorage only. The Building Design Professional is responsible for the foundation design is permitted to design detail alternative anchorage. 1A / FDN: Hardy Frame - Anchorage for 1-1/8 inch Diameter Anchors

51 ESR-2089 Most Widely Accepted Trusted Page 51 of 58 Hardy Frame BRACE FRAMES 2009 AND 2006 IBC ANCHORAGE FOR / 8 -INCH DIAMETER ANCHORS (A b =0.601 in 2 ) 1,4,8 Concrete Compressive Strength 2,500 psi 3,000 psi 4,000 psi Design Load 2 Concrete Condition at Service Load Anchorage Call-Out 3 5 T ASD l e 6 C a1 & C a2 l e 6 C a1 & C a2 l e 6 C a1 & C a2 Cracked Uncracked Cracked Uncracked STD-SA 13, ' STD-SB 10, HS-SA 28, HS-SB 1, HS-SC 12, STD-SC 13, STD-SD 10, HS-SD 28, HS-SE 1, HS-SF 12, STD-WA 13, HS-WA 28, HS-WB 20, HS-WC 14, HS-WD 12, STD-WB 13, HS-WE 28, HS-WF 20, HS-WG 14, HS-WH 12, For SI: 1 inch = 25.4 mm, 1 in 2 = 645 mm 2, 1 lbf = 4.45 N. 1 Anchorage design complies with ACI 318 Appendix D Condition B with no supplemental reinforcement for cracked uncracked normal weight concrete with the tabulated minimum specified compressive strength. Cracked concrete occurs where analysis indicates cracking (f t > f r ) at service load levels. 2 In Design Categories (SDC) A B for detached 1 2 family dwellings in SDC A, B, C, wind values apply. 3 STD indicates steel anchor bolts complying with ASTM F 1554 Grade 36. HS indicates steel anchor rods complying with a high strength steel specification as set forth in Section 3..4 of this Report. 4 A b is the nominal cross sectional area of the Hold down Anchor. 5 T ASD is the Stress Design tension load. 6 l e is the embedment depth into a foundation that provides the minimum edge end distance requirements C a1 C a2. C a1 is the minimum end distance C a2 is the minimum edge distance to the centerline of the Hold down Anchor. 8 Foundation dimensions consider anchorage only. The Building Design Professional is responsible for the foundation design is permitted to design detail alternative anchorage. 1B / FDN: Hardy Frame - Anchorage for /8 inch Diameter Anchors

52 ESR-2089 Most Widely Accepted Trusted Page 52 of 58 1) SUPPLEMENTAL SHEAR REINFORCEMENT REQUIREMENT IN ACCORDANCE WITH ACI 318 fc = 2500 psi 2) APPLICABLE FDR BOTH WIND AND SEISMIC DESIGN 3) SHEAR REINFORCEMENT IS NOT REQUIRED AT PANELS AND BRACE FRAMES SUPORTED ON WOOD FRAMING OR LOCATED AWAY FROM FOUNDATION EDGES (INTERIOR FOUNDATION) 4) SUPPLEMENTAL SHEAR REINFORCEMENT IS NOT REQUIRED FOR BRACED WALL PANEL APPLICATIONS SET FORTH IN IBC SECTION OR IRC SECTION R602 5) REQUIRE A MINIMUM 6 in. CURB OR STEMWALL WIDTH 6) CONCRETE EDGE DISTANCE FOR ANCHORS MUST COMPLY WITH ACI 318 D.8.2.3

ICC-ES Evaluation Report

ICC-ES Evaluation Report ICC-ES Evaluation Report ESR-2369 Reissued May 1, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

DIVISION: 04 00 00 MASONRY SECTION: 04 05 19.16 MASONRY ANCHORS REPORT HOLDER: HILTI, INC. 7250 DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: 04 00 00 MASONRY SECTION: 04 05 19.16 MASONRY ANCHORS REPORT HOLDER: HILTI, INC. 7250 DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024 0 ICC-ES Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 Most Widely Accepted and Trusted ESR-3342 Reissued 08/2015 This report is subject to renewal 08/2017. DIVISION: 04 00 00 MASONRY

More information

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH 84042 EVALUATION SUBJECT:

REPORT HOLDER: JENWEST ENTERPRISES LLC, DBA ADVANCED CONNECTOR SYSTEMS 321 SOUTH 1240 WEST #15 LINDON, UTAH 84042 EVALUATION SUBJECT: 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3635 Reissued 04/2016 This report is subject to renewal 04/2018. DIVISION: 03 00 00 CONCRETE

More information

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015 0 ICC ES Report ICC ES (800) 42 6587 (562) 699 054 www.icc es.orgg 000 Most Widely Accepted and Trusted ESR 2269 Reissued 02/205 This report is subject to renewal 02/207. DIVISION: 0 00 00 CONCRETE SECTION:

More information

Discipline: Structural Issued 04-26-06

Discipline: Structural Issued 04-26-06 California Department of General Services. Division of the State Architect. Product Acceptance Report STRUCTURAL SHEAR PANEL SURE-BOARD SERIES 200 PANELS PA-132 Discipline: Structural Issued 04-26-06 This

More information

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006

More information

Chapter 6 ROOF-CEILING SYSTEMS

Chapter 6 ROOF-CEILING SYSTEMS Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;

More information

LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 23 WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 23 WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: 0 ICC ES Report ICC ES (800) 4 6587 (56) 699 054 www.icc es.org 000 Most Widely Accepted and Trusted ESR 0 Reissued 07/06 This report is subject to renewal 07/07. DIVISION: 06 00 00 WOOD, PLASTICS AND

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor Supplement to Hilti North American Product Technical Guide Volume 2: Anchor Fastening Technical Guide 2011 Edition 3.3. KWIK

More information

Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com

Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,

More information

Featuring TJ Rim Board and TimberStrand LSL

Featuring TJ Rim Board and TimberStrand LSL #TJ-8000 SPECIFIER S GUIDE TRUS JOIST RIM BOARD Featuring TJ Rim Board and TimberStrand LSL Multiple thicknesses, grades, and products to cover all your rim board needs 1¼" Thickness matches lateral load

More information

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year. ICC-ES Evaluation Report ESR-2270 Reissued September, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE SECTION 2.2 PAGE 1 / 9 l DESCRIPTION UCAN TZ torque controlled mechanical expansion wedge anchors have a Category 1 classification. They are used to resist static, wind and seismic tension and shear loads

More information

6 RETROFITTING POST & PIER HOUSES

6 RETROFITTING POST & PIER HOUSES Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This

More information

THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials.

THE DOW CHEMICAL COMPANY Issued: August 1, 2008 200 LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN 48674 (989) 638-8655 www.dowbuildingmaterials. ICC EVALUATION SERVICE, INC. EvaluateP InformP Protect Los Angeles Business/Regional OfficeP 5360 Workman Mill RoadP Whittier, CA 90601 (562) 699-0543 phonep (562) 695-4694 fax DIVISION: Section: 6 WOOD

More information

Submittal Information

Submittal Information Wedge SPECIFIED FOR ANCHORAGE INTO CONCRETE Wedge anchs feature a stainless steel expansion clip, threaded stud body, nut and washer. Anch bodies are made of plated carbon steel, hot-dipped galvanized

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Connection Solutions

Connection Solutions Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND

More information

Wisconsin Building Products Evaluation

Wisconsin Building Products Evaluation Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation

More information

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as

More information

CPA Steel Stud Framing Page 1 of 11

CPA Steel Stud Framing Page 1 of 11 CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#

More information

Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com

Hilti, Inc. 5400 South 122 nd East Avenue Tulsa, OK 74146. 1-800-879-8000 www.hilti.com Attached are page(s) from the 2014 Hilti North American Product Tech Guide. For complete details on this product, including data development, product specifications, general suitability, installation,

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 32 16 CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 32 16 CONCRETE ROOF TILES REPORT HOLDER: 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1900 Reissued 03/2016 This report is subject to renewal 03/2017. DIVISION: 07 00 00 THERMAL

More information

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16. The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16. Please refer to the publication in its entirety for complete details on this product

More information

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Introduction...COMB-2 Design Considerations and Examples...COMB-3 SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety

More information

STANDARD OPEN PATIO COVER

STANDARD OPEN PATIO COVER STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist

More information

Seismic Technical Guide

Seismic Technical Guide Technical Document Seismic Technical Guide Hanger Wire Attachment Code Requirements 1 The International Building Code (IBC) defines the requirement for hanger wire and their supports and attachment methods.

More information

Formwork for Concrete

Formwork for Concrete UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev. Structural Bolting ASTM A325 and ASTM A490 are the two U.S. standard structural bolts. When looking at the mechanical requirements of bolts it appears that an ASTM A325 and SAE J429 Grade 5 are identical

More information

Bracing Webs in Trusses that have Dissimilar Configurations

Bracing Webs in Trusses that have Dissimilar Configurations Bracing Webs in Trusses that have Dissimilar Configurations Released April 25, 2006 Issue: Truss Design Drawings (TDD) that are prepared in accordance with ANSI/TPI 1, National Design Standard for Metal

More information

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years. ICC-ES Evaluation Report ESR-90 Reissued December, 2009 This report is subject to re-examination in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council

More information

Perforated Shearwall Design Method 1

Perforated Shearwall Design Method 1 Perforated Shearwall Design Method 1 Philip Line, P.E., Bradford K. Douglas, P.E., American Forest & Paper Association, USA Abstract Wood frame shearwalls are traditionally designed using full-height shearwall

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

COMMONLY USED RESIDENTIAL BUILDING CODES

COMMONLY USED RESIDENTIAL BUILDING CODES COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section

More information

DIVISION: 10 00 00 SPECIALTIES SECTION: 10 73 00 PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC.

DIVISION: 10 00 00 SPECIALTIES SECTION: 10 73 00 PROTECTIVE COVERS REPORT HOLDER: METALS BUILDING PRODUCTS/LATIUM USA TRADING, INC. 0 ICC ES Report ICC ES (800) 23 6587 (562) 699 053 www.icc es.org 000 Most Widely Accepted and Trusted ESR 1953 Reissued 06/2016 This report is subject to renewal 06/2017. DIVISION: 10 00 00 SPECIALTIES

More information

Design of Cold-Formed Steel Shear Walls

Design of Cold-Formed Steel Shear Walls DESIGN GUIDE 2 Design of Cold-Formed Steel Shear Walls March 1998 The following publication was developed by R.L. Brockenbrough & Associates for the American Iron and Steel Institute (AISI), In the production

More information

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE.

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. www.r-control.com CONTROL, NOT COMPROMISE. R-CONTROL s STRUCTURAL INSULATED PANELS Note: Information deemed reliable at time of printing. Please visit www.r-control.com for latest information. June 2012 CONTROL, NOT COMPROMISE. www.r-control.com

More information

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections Materials Standard shapes W sections, C channels, Structural T, Angles, Pipes, Tubes, Rods and Plates Fabricated members, Built-up sections Adding plates to beam flanges, Stiffeners to beam webs Built

More information

Technical Notes 3B - Brick Masonry Section Properties May 1993

Technical Notes 3B - Brick Masonry Section Properties May 1993 Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE-PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI

More information

DIVISION: 31 00 00 EARTHWORK SECTION: 31 63 00 BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC.

DIVISION: 31 00 00 EARTHWORK SECTION: 31 63 00 BORED PILES REPORT HOLDER: HUBBELL POWER SYSTEMS, INC. 0 ICC ES Report ICC ES (800) 4 6587 (56) 699 054 www.icc es.org 000 Most Widely Accepted and Trusted ESR 794 Reissued 05/05 This report is subject to renewal 05/06. DIVISION: 00 00 EARTHWORK SECTION: 6

More information

METHOD OF STATEMENT FOR STATIC LOADING TEST

METHOD OF STATEMENT FOR STATIC LOADING TEST Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents

More information

4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections. Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls

More information

www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council *Revised April 2014

www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council *Revised April 2014 ICC-ES Evaluation Report ESR-1647* Issued July 2013 This report is subject to renewal August 1, 2015. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION:

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

PC-Concrete Injectable Concrete Anchoring and Repair System

PC-Concrete Injectable Concrete Anchoring and Repair System PC-Concrete Injectable Concrete Anchoring and Repair System DESCRIPTION: PC-Concrete is a two component (1:1 ratio), 100% solids, high modulus, structural epoxy paste. PC-Concrete is a solvent free, no

More information

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading: SEISMIC DESIGN Various building codes consider the following categories for the analysis and design for earthquake loading: 1. Seismic Performance Category (SPC), varies from A to E, depending on how the

More information

Mark Cramer Inspection Services, Inc.

Mark Cramer Inspection Services, Inc. Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction

More information

LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council. *Corrected March 2014

LEGACY REPORT. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council. *Corrected March 2014 ICC-ES Legacy Report PFC-3700* Issued October 2003 www.icc-es.org (00) 423-57 (52) 99-0543 A Subsidiary of the International Code Council Legacy report on the 1997 Uniform Building Code and the 2000 International

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-900* Reissued March, 20 This report is subject to renewal in one year. A Subsidiary of the International Code Council DIVISION:

More information

Narrow Wall Bracing. Prescriptive Method 1-07. Hardy Frame

Narrow Wall Bracing. Prescriptive Method 1-07. Hardy Frame Narrow Wall racing Prescriptive Method 1-07 ompany and Product Profile Hardy Frames, Inc. manufactures and markets the revolutionary shear wall system. The is a state of the art pre-fabricated shear panel

More information

LP OSB Sheathing & Structural 1 Sheathing

LP OSB Sheathing & Structural 1 Sheathing Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48

More information

Typical Deck Details

Typical Deck Details Fairfax County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code The design details in this document apply to residential, single-level decks only. Construction cannot deviate

More information

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data Technical data HUS-H Carbon steel screw anchor HUS-H diameter 8, 10, 14 10 / 011 Version 011-10 1 HUS-H screw anchor seismic design data Anchor version Carbon steel screw Benefits - Quick and easy setting

More information

STRUCTURAL TESTS AND SPECIAL INSPECTIONS

STRUCTURAL TESTS AND SPECIAL INSPECTIONS CHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONS SECTION 1701 GENERAL 1701.1 Scope. The provisions of this chapter shall apply to Class I buildings and shall govern the quality, workmanship and requirements

More information

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars

Report on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of

More information

RPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130

RPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130 RPS - sales@rpssolar.com - 858 755 4505-2478 San Bruno Cove, San Diego, CA 9230 SWH Solar Mount Rail R-MR-SW-SR-0.5, R-MR-SW-SR-2, R-MR-SW-SR-4, R-MR-SW-SR-4B, R-MR-SW-SR-7 Part No. MR-SW-SR-0.5, MR-SW-SR-2,

More information

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC UL 580 TEST REPORT Rendered to: ARMSTRONG WORLD INDUSTRIES SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC Report No.: Test Dates: 12/14/09 Through: 12/22/09 Report Date: 03/12/10 Expiration

More information

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14 Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318

More information

Detailing of Reinforcment in Concrete Structures

Detailing of Reinforcment in Concrete Structures Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For

More information

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General

More information

4.3.5 - Breakaway Walls

4.3.5 - Breakaway Walls 4.3.5 - Breakaway Walls Elevation of a structure on a properly designed foundation reduces the potential for water damage from flooding. When the space below the lowest elevated floor is maintained free

More information

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards

More information

Steel joists and joist girders are

Steel joists and joist girders are THE STEEL CONFERENCE Hints on Using Joists Efficiently By Tim Holtermann, S.E., P.E.; Drew Potts, P.E.; Bob Sellers, P.E.; and Walt Worthley, P.E. Proper coordination between structural engineers and joist

More information

CHAPTER 6 CONSTRUCTION TYPES

CHAPTER 6 CONSTRUCTION TYPES CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use

More information

Chapter 3 - Structural Design

Chapter 3 - Structural Design Chapter 3 - Structural Design 3.0 General 3.0.1 Design Overview Greenhouse buildings are a complete structure including the structural support and enclosure elements. The primary structural system includes:

More information

Common Errors in Truss Design

Common Errors in Truss Design In today s competitive world of trusses, component manufacturers are always looking for ways to generate more efficient truss designs. Occasionally, truss designs need to be changed in order to be sealed

More information

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY Purpose and Intended Audience The August 24, 2014 South Napa Earthquake has again served as a reminder that

More information

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.

More information

High Strain Dynamic Load Testing of Drilled Shafts

High Strain Dynamic Load Testing of Drilled Shafts Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain

More information

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS. Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION

More information

Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing

Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Standard from CSI Part Section Format. 06212 For Wood Framing 05160 For Metal Framing 09226 For Gypsum Sheathing Specifications for SURE-BOARD Series 200 and 200W Panel for shear PART 1.0 GENERAL 1.01

More information

Uncovered Decks & Porches

Uncovered Decks & Porches Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed

More information

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed

More information

USP SIP Connection Manual

USP SIP Connection Manual USP SIP Connection Manual Structural Insulated Panels (SIP) Lumberton Largo Montgomery Humble Livermore Thornhill, Ontario Copyright 2013 United Steel Products Company 2 Company Information Company History

More information

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS Chapter 3 FOUNDATIONS AND FOUNDATION WALLS This chapter discusses foundations and foundation walls constructed using the two most common foundation materials concrete and masonry. Although the IRC permits

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

TYPICAL PATIO COVERS 111

TYPICAL PATIO COVERS 111 City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS HELENA JUBANY PRESIDENT VAN AMBATIELOS VICE-PRESIDENT E. FELICIA BRANNON VICTOR H. CUEVAS GEORGE HOVAGUIMIAN CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049 Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal

More information

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN

SPECIFICATIONS, LOADS, AND METHODS OF DESIGN CHAPTER Structural Steel Design LRFD Method Third Edition SPECIFICATIONS, LOADS, AND METHODS OF DESIGN A. J. Clark School of Engineering Department of Civil and Environmental Engineering Part II Structural

More information

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS INTERIM PRESIDENT E. FELICIA BRANNON JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR

More information

Hilti HIT-V and HAS Threaded Rod and Hilti HIT-Z Anchor Rod

Hilti HIT-V and HAS Threaded Rod and Hilti HIT-Z Anchor Rod , Monday, HAS March and HIT-Z 24, 2014 Hilti Rod Specifications and Technical Data Hilti and HAS Threaded Rod and Hilti HIT-Z Rod Specifications and Technical Data Hilti has provided threaded rod for many

More information

Seismic Installation for Attic Storage System

Seismic Installation for Attic Storage System Your Performance Partner Seismic Installation for Storage System CONTENTS SSafety Precautions................................. 2 Required Tools..................................... 2 Parts and Fastener

More information

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide

More information

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)

More information

Page & Turnbull imagining change in historic environments through design, research, and technology

Page & Turnbull imagining change in historic environments through design, research, and technology DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED

More information

Residential Decks. Planning and Development Services Department

Residential Decks. Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks

More information