CONCRETE SEGMENTAL RETAINING WALLS

Size: px
Start display at page:

Download "CONCRETE SEGMENTAL RETAINING WALLS"

Transcription

1 CONCRETE SEGMENTAL RETAINING WALLS 1.00 GENERAL 1.01 DESCRIPTION A. The work shall consist of furnishing and installing concrete segmental retaining wall (CSRW) units to the lines, grades and dimensions shown on the detailed drawinsg and as specified herein. B. Work includes furnishing leveling pad, unit fill and backfill material as specified herein and as shown on the construction shop drawings. C. Work includes furnishing approved CSRW facing and cap units as shown on the construction shop drawings. D. Work includes installation of wall drainage system as shown on the construction shop drawings. E. Work includes furnishing soil reinforcement as shown on the construction shop drawings DEFINITIONS A. Concrete Segmental Retaining Wall Facing (CSRW) Units: a preapproved facing unit which meets all physical and performance criteria in this specification, as determined by the ENGINEER prior to award of the contract, machine made from Portland Cement, water and mineral aggregates. B. CSRW Cap Unit: a unit designed specifically to top or finish an approved CSRW Unit. C. Unit Fill: aggregate fill placed in the open areas of CSRW units. D. Foundation Soil: compacted or in-situ soil beneath the entire wall. E. Soil Reinforcement Geogrid: a structural geotextile formed by a regular network of integrally connected tensile elements with apertures of sufficient size to allow interlocking with surrounding soil, rock or earth and function primarily as structural reinforcement, as specified in Division 31 Section GEOGRID SOIL REPLACEMENT. F. Reinforced Backfill: compacted soil which is reinforced with geogrid, as defined by the reinforced soil volume indicated on the plans. G. Retained Soil: compacted or in-situ soil behind the reinforced backfill zone. H. Leveling Pad: a level compacted gravel or unreinforced concrete footing upon which the first course of CSRW units are placed REFERENCE DOCUMENTS A. Geosynthetic Research Institute GG1-87 Standard Test Method for Geogrid Rib Tensile Strength GG2-87 Standard Test Method for Geogrid Junction Strength GG3 (a&b)-91 Tension Creep Testing of (Stiff & Flexible) Geogrids GG4 (a&b)-91 Determination of Long-Term Design Strength of (Stiff & Flexible) Geogrids Concrete Segmental Retaining Wall

2 GG5-91 Geogrid Pullout B. American Society for Testing and Materials Standards ASTM CB-90 Specification for Concrete Aggregates ASTM C Hollow Load-Bearing Masonry Units ASTM C Methods of Sampling and Testing Concrete Masonry Units ASTM C Solid Load Bearing Concrete Masonry Units ASTM C Specification for Portland Cement ASTM C Specification for Blended Hydraulic Cements ASTM D-698 Moisture Density Relationship for Soils, Standard Method ASTM D-1557 Modified Proctor Density ASTM D-422 Gradation Analysis ASTM D-4318 Atterberg Limits ASTM D-4595 Tensile Properties of Geotextiles by the Wide-Width Strip Method ASTM D-4632 Tensile Properties of Geotextiles ASTM D-52 Tensile Creep Testing of Geosynthetics ASTM G Resistivity ASTM G Alkalinity C. NCMA TEK 50 A Specifications for Segmental Retaining Wall Units D. NCMA SRWU-1 Determination of Connection Strength between E. Geosynthetics and Segmental Concrete Units F. NCMA SRWU-2 Determination of Shear Strength between Segmental G. Concrete Units H. NCMA Design Manual for Segmental Retaining Wall 1.04 SUBMITTALS Submittals shall be in accordance with Division 1 Section SUBMITTALS PROCEDURES, and shall include: A. A minimum of the previous two years experience and a minimum of 40,000 square feet of documentable satisfactory experience installing Soil Reinforced Segmental Retaining Walls over eight feet in height. Provide a project list indicating the required experience before beginning construction of CSRW walls. B. Manufacturer s specifications (latest edition) for proposed materials, method of installation, and list of materials proposed for use. C. Samples of CSRW units showing finish and potential color variation shall be provided to the OWNER prior to construction. D. A notarized manufacturer s certification prior to start of work stating the CSRW system meets the requirements of this specification. E. A certificate of compliance with test report documentation certifying that the reinforced backfill materials comply with Section 2.03 of this specification. F. Detailed CSRW shop drawings, sealed by a Professional Engineer licensed in the state where the wall is to be constructed, including: Concrete Segmental Retaining Wall

3 1. Proprietary product literature indicating specifically which CSRW units are proposed for use on the project, including color, face style, and texture. 2. Proprietary product specifications indicating compressive strength, unit weight, aggregate mix, and percent absorption for the units proposed. 3. Proprietary product literature for soil reinforcements proposed for use in the CSRW system indicating exactly which reinforcements are to be used, wide width tensile strength, and results of 10,000 hour testing. This information should also include manufacturer recommended reduction factors for creep, biological/chemical damage, installation damage, factor of safety for uncertainties, and any other reductions identified by the manufacturer to be used for design with the proposed reinforcement. 4. Results of connection strength testing performed by a certified testing laboratory for the specific CSRW unit and specific soil reinforcements proposed according to NCMA test method SRWU Results of shear strength testing between CSRW units performed by a certified testing laboratory according to NCMA test method SRWU Wall profiles, reinforcement elevations, reinforcement lengths, reinforcement types, top of wall, bottom of wall, proposed grades at top of wall, and stations showing beginning of and ending of wall as well as the beginning and ending of turns and radii. 7. Design parameters for the retaining wall, including the design criteria specified herein, required bearing capacity of wall subgrade, and construction details. 8. Hand calculations and/or computer output accompanied by hand calculations addressing required design parameters according to NCMA recommendations. 9. A certificate of Errors and Omissions Insurance with a minimum value of $500,000 per occurrence for the Licensed Professional Engineer sealing the shop drawings DELIVERY, STORAGE AND HANDLING A. Check the materials upon delivery to assure the specified type, grade, color and texture of CSRW units have been received. B. Prevent excessive mud, wet concrete, epoxies, and like materials which may affix themselves, from coming in contact with the materials. C. Protect the materials from damage. Damaged material shall not be incorporated into the retaining wall structure SPECIAL PROVISIONS A. Unless otherwise shown on the plans, wall batter shall be a maximum of 4 degrees. Blocks shall be placed horizontally, and positive means of obtaining batter shall be provided. B. The Contractor s Professional Engineer responsible for design of the CSRW wall shall interpret subsurface conditions within the CSRW foundation area, and shall provide recommendations for any subsoil improvements required. Foundation area of concrete segmental retaining walls shall be taken to extend from a minimum of 6 inches from the front face of the block to the horizontal extent of the geogrid reinforcement. C. Include the cost of all means of subsoil improvement as recommended by the Contractor s Professional Engineer in the unit price bid per SF of facing area. D. Prior to undertaking any grading or excavation of the site, survey to confirm the location of the retaining walls, as well as any underground features, including utility locations within the area of construction. Concrete Segmental Retaining Wall

4 E. Coordinate installation of underground utilities with wall installation. F. Minimum geogrid length shall be five feet or 70 percent of the wall height, whichever is greater. G. The Design Criteria for the CSRW system shall be: 2.00 MATERIALS 1. Internal Stability of Walls: Minimum Factor of Safety on Tensile Overstress 1.0 Minimum Factor of Safety on Geogrid Pullout 1.5 (peak load criterion) Minimum Factor of Safety on Geogrid Pullout 1.0 (serviceability criterion) Minimum Factor of Safety on Facing Shear 1.5 (peak load criterion) Minimum Factor of Safety on Facing Shear 1.0 (serviceability criterion) Minimum Factor of Safety for Connections 1.5 (peak load criterion) Minimum Factor of Safety for Connections 1.0 (serviceability criterion) Minimum Factor of Safety for Uncertainties External Stability of Walls: Minimum Factor of Safety Against Base Sliding 1.5 (static condition) Minimum Factor of Safety Against Overturning 2.0 Minimum Factor of Safety for Global Stability 1.5 Minimum Factor of Safety for Bearing Capacity Design shall address hydrostatic loading, seismic loading, rapid drawdown, surcharge, velocity effects, and back slopes where appropriate SEGMENTAL RETAINING WALL UNITS A. CSRW units shall meet all physical and performance criteria set forth in this specification and the construction shop drawings. CSRW units made by the following manufacturers have been determined to meet the requirements of this specification inch depth Anchor Vertica Pro, as manufactured by Pavestone Anchor Wall Systems. 2. Compact Unit, as manufactured by Keystone Retaining Wall Systems. B. CSRW units shall meet the following structural requirements: 1. Concrete used to form all CSRW units including cap units shall have a minimum net 28- day compressive strength of 3,000 psi. The CSRW units shall have adequate freeze/thaw protection, as indicated by a maximum absorption rate of 8 percent. 2. Cementitious materials used in the manufacture of the units shall be Type I, Type II or Type III Portland cement in accordance with ASTM C Other constituents: Air entraining agents, coloring pigments, integral water repellents, finely ground silica and other constituents previously established as suitable for use in segmental retaining wall units, conforming to applicable ASTM Standards or shown by test or experience to be not detrimental to the durability of the segmental concrete facing units or to any material used in masonry construction. Concrete Segmental Retaining Wall

5 4. Exterior dimensions of units may vary in accordance with ASTM C 90. CSRW concrete facing unit dimensions shall not differ more than " 1/8 inch from the manufacturer s molded dimension, nor more than 1/16 inch in height from front to back of unit. 5. CSRW units shall provide a minimum weight equivalent to 125 pcf. Unit fill placed within the dimensions of the units may be considered as 80 percent of the effective unit weight. 6. Only CSRW Systems with positive interlocking fascia connections such as pins, locators, lips, keyways, or clips are acceptable. 7. If fiberglass connecting pins are required, the pins shall be 2 diameter thermoset isopthalic polyester resin-protruded fiberglass reinforcement rods, with a minimum flexural strength of 128,000 psi and a short beam shear of 6,400 psi. C. FINISH AND APPEARANCE All CSRW units shall be sound and free of cracks or other defects that would interfere with the proper placing of the unit or significantly impair the strength or permanence of the construction. D. SAMPLING AND TESTING Compressive strength test specimens shall conform to the saw-cut coupon provisions of Section of ASTM C 140 with the following exception: 1. Coupon shall have a minimum thickness of 1-1/2 inches BASE LEVELING PAD MATERIAL AND UNIT FILL FOR BLOCK A. Base Leveling Pad Material: For channel walls, the base leveling pad material shall be either an extension of the 6 concrete channel lining, or lean, unreinforced Class E concrete 6 thick. For overbank walls, the base leveling pad shall be lean, unreinforced Class E concrete 2 thick or compacted granular fill as specified in Division 31 Section COMPACTED FILL. The base leveling pad shall be constructed to the elevations shown in the approved construction shop drawings. B. Unit Fill: Fill for units shall consist of granular fill as specified in Division 31 Section COMPACTED FILL. C. Drainage Backfill: For all CSRW wall sections, place a minimum of 12 of granular fill behind the CSRW units, as shown in the Contract Drawings and construction shop drawings REINFORCED WALL BACKFILL A. Soils with more than 35% passing the No. 200 sieve, soils with Plastic Index greater than 10, soils with Angle of Internal Friction less than 30 degrees as indicated by Consolidated Drained Triaxial Testing and soils not free of organic material shall not be permitted for use in the reinforced zone. B. Wall backfill material reinforced with geogrid shall have a ph in the range of 3 to 10 as determined in accordance with ASTM G51. C. Do not run mechanical vibrating plate compactors on top of the CSRW units. Compaction of fill between CSRW units and the three foot zone behind the CSRW units shall be accomplished by running hand-operated compaction equipment just behind units. Compact fill to minimum 95% Standard Proctor Density (ASTM D 698). D. The reinforced backfill shall be placed in maximum 8-inch-thick compacted lifts, and shall be compacted to a minimum of 95% Standard Proctor Density (ASTM D 698). Concrete Segmental Retaining Wall

6 E. Furnish to the ENGINEER a Certificate of Compliance certifying that the reinforced backfill materials comply with this section of the specifications RETAINED BACKFILL OR COMMON BACKFILL A. Soil placed behind the reinforced backfill shall be general earth backfill, as described in Division 31 Section COMPACTED FILL. B. Retained backfill shall be compacted as recommended in Division 31 Section COMPACTED FILL EXECUTION 3.01 EXCAVATION A. Excavate to the lines and grades shown on the Drawings. Take precautions to minimize over-excavation. Over-excavation shall be filled with approved compacted material at the CONTRACTOR s expense. Do not to disturb embankment materials beyond the lines shown on the Drawings. B. Excavation of unsuitable soils and replacement with approved compacted material shall be performed in accordance with Section 31, COMPACTED FILL. Contractor s Professional Engineer responsible for design of the CSRW wall shall inspect the excavation and furnish a report approving the subgrade prior to placement of leveling pad material. C. Over-excavated areas in front of wall face shall be filled with approved compacted material at the CONTRACTOR s expense before the wall is built to over four feet in height. D. Verify location of existing structures and utilities prior to excavation. Ensure all surrounding structures are protected from the effects of wall excavation. E. Coordinate installation of new utilities and improvements to existing utilities with wall installation. F. In areas where soft, disturbed or otherwise unsuitable soils are encountered within the zone of influence of the wall loading in the excavations, such unsuitable soils shall be overexcavated to the depths and extent indicated in the contract documents and replaced with suitable material as described in Section 31, COMPACTED FILL LEVELING PAD CONSTRUCTION A. Leveling pad shall be placed as shown on the construction shop drawings. The leveling pad should extend laterally a minimum distance of 6 inches from the toe and heel of the lower most CSRW unit. B. Foundation soil for the leveling pad shall be proof rolled and the top 12 inches compacted to minimum 95% Standard Proctor Density (ASTM D 698) and tested prior to placement of leveling pad materials. C. For overbank walls, compacted granular fill is allowable. The granular leveling pad material shall be compacted to provide a level hard surface on which to place the first course of CSRW units. Well-graded sand can be used to smooth the top 2 to 3 inch of the leveling pad. Alternatively, use a bed of mortar on top of the leveling pad to level the first course of CSRW units. Compaction will be with mechanical plate compactors to minimum 95% of Standard Proctor Density (ASTM D 698). Concrete Segmental Retaining Wall

7 3.03 CSRW UNIT INSTALLATION A. First course of CSRW units shall be placed on the leveling pad. The CSRW units shall be leveled side-to-side, front-to-rear and aligned with adjacent units. The first course is the most important to ensure accurate and acceptable results. Ensure CSRW units are in full contact with the leveling pad. B. Place the front of the CSRW units side-by-side, and shall not leave gaps between the front of adjacent units. Alignment may be done by means of a string line or offset from base line to the back of the units. Layout of curves and corners shall be in accordance with CSRW manufacturer s installation guidelines. C. Install fascia block connections per CSRW manufacturer s recommendations, and place fiberglass connecting pins (if required). Fill all voids of CSRW units with unit fill and tamp fill. D. Place and compact drainage fill between and behind units, and place and compact infill soil behind drainage fill. E. Sweep all excess debris from top of units and install next course. Ensure that each course is completely unit filled, backfilled, and compacted prior to proceeding to the next course. F. Repeat procedure to the extent of wall height, checking alignment every 3 courses to ensure level rows of CSRW units. Stacking of CSRW units without placing core fill in the previous course of units will not be permitted. G. As appropriate where the top of the wall changes elevation, units can be stepped with grade or turned into the embankment with a convex return end. Provide appropriate buried units on compacted leveling pad in the area of the convex return end CAP INSTALLATION A. Place CSRW Cap units per manufacturer s recommendations. Backfill and compact to finished grade. B. Permanent mechanical connection of Cap units to CSRW units shall be provided by construction epoxy. Apply adhesive to bottom surface of Cap unit and install on CSRW units below. Adhesive shall be as recommended by the CSRW manufacturer. END OF SECTION Concrete Segmental Retaining Wall

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13) Page 1 of 7 STONE STRONG SYSTEMS SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised ) PART 1: GENERAL 1.01 Description A. Work includes furnishing and installing precast modular blocks

More information

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Classic 8 with PCS unit segmental retaining wall

More information

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1: GENERAL SPECIFICATIONS 1.01 Work Included A. Work shall consist of furnishing and constructing a Rockwood Vintage TM unit segmental retaining wall (SRW)

More information

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Specification Guidelines: Allan Block Modular Retaining Wall Systems Specification Guidelines: Allan Block Modular Retaining Wall Systems The following specifications provide Allan Block Corporation's typical requirements and recommendations. At the engineer of record's

More information

1. ASTM C 140 - Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

1. ASTM C 140 - Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units SPECIFICATION FOR SEGMENTAL RETAINING WALL SYSTEMS PART 1: GENERAL 1.01 Description A. Work shall consist of furnishing materials, labor, equipment and supervision to install a segmental retaining wall

More information

SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM Section 32 32 23 Concrete Segmental Retaining Wall Page 1 of 12 PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM A. Concrete segmental retaining wall units.

More information

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission. SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS Prepared by Risi Stone Systems Used by permission. 1-800-UNILOCK www.unilock.com FOREWORD This outline specification has been prepared for

More information

SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM Anchor [coarse-split products] SECTION 32 32 23 CONCRETE SEGMENTAL RETAINING WALL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Concrete segmental retaining wall units 2. Geosynthetic reinforcement

More information

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP) SPECIFICATIONS INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP) Part 1 General 1.1 CONFORMITY Conforms to the requirements of the general conditions of the contract.

More information

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com

RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL 11 Featuring Highland Stone anchorwall.com TABLE OF CONTENTS 2 TABLE OF CONTENTS BEFORE YOU BEGIN............................

More information

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains

More information

C. Section 014510 TESTING LABORATORY SERVICE.

C. Section 014510 TESTING LABORATORY SERVICE. SECTION 014500 QUALITY CONTROL PART 1 GENERAL 1.01 RELATED REQUIREMENTS A. Drawings and General Provisions of Contract, including General and Special Conditions and other Division 1 Specification Sections,

More information

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS Section Page 36-1 GENERAL... 36.1 36-2 PIPEMAKING EQUIPMENT... 36.1 36-3 TRENCH EXCAVATION... 36.1 36-4 SPECIAL FOUNDATION TREATMENT...

More information

SECTION 31 20 00 EARTH MOVING

SECTION 31 20 00 EARTH MOVING SECTION 31 20 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for excavating, filling, and grading for earthwork at Parking Structure, new exit stair and as required to

More information

SECTION 1 GENERAL REQUIREMENTS

SECTION 1 GENERAL REQUIREMENTS Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,

More information

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION 33 41 13 PUBLIC STORM UTILITY DRAINAGE PIPING SECTION 33 41 13 PUBLIC STORM PART 1 - GENERAL 1.01 SECTION INCLUDES A. Storm drainage piping, fittings, and accessories at proposed station areas and locations other than under and immediately adjacent

More information

Division 2 Section 32 14 13.19 Section 02795

Division 2 Section 32 14 13.19 Section 02795 Note: The text must be edited to suit specific project requirements. It should be reviewed by a qualified civil or geotechnical engineer, or landscape architect familiar with the site conditions. Edit

More information

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition. Design Guide Basis of Design This section applies to the design and installation of earthwork and backfill. Design Criteria No stockpiling of excavation materials is allowed unless the Geotechnical Engineer

More information

DIVISION 300 BASES SECTION 304 AGGREGATE BASE COURSE DESCRIPTION MATERIALS CONSTRUCTION REQUIREMENTS

DIVISION 300 BASES SECTION 304 AGGREGATE BASE COURSE DESCRIPTION MATERIALS CONSTRUCTION REQUIREMENTS 304.06 DIVISION 300 BASES SECTION 304 AGGREGATE BASE COURSE DESCRIPTION 304.01 This work consists of furnishing and placing one or more courses of aggregate and additives, if required, on a prepared subgrade.

More information

SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT A. The requirements for construction of permeable interlocking concrete pavement: 1. Install the interlocking

More information

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES

SECTION 33 05 16.13 PRECAST CONCRETE UTILITY STRUCTURES SECTION 33 05 16.13 PRECAST CONCRETE PART 1 - GENERAL 1.01 SECTION INCLUDES A. This item shall consist of the construction of both sanitary and storm sewer precast concrete manholes in accordance with

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by

More information

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS December 2014 CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS 1. DESCRIPTION... 1 1.1 General... 1 1.2 Definitions... 1 1.3 Referenced Standard Construction Specifications...

More information

SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.

SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250. 02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily

More information

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone GEOSYNTHETIC SOIL REINFORCEMENT Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone DESIGN MANUAL & KEYWALL OPERATING GUIDE GEOSYNTHETIC SOIL REINFORCEMENT Keystone retaining walls

More information

40-9 PERMEABLE INTERLOCKING CONCRETE PAVEMENT

40-9 PERMEABLE INTERLOCKING CONCRETE PAVEMENT 40-9 PERMEABLE INTERLOCKING CONCRETE PAVEMENT 40-9.01 GENERAL 40-9.01A Summary Section 40-9 includes specifications for furnishing and installing concrete pavers for permeable interlocking concrete pavement

More information

Section 2100-Trenching and Tunneling

Section 2100-Trenching and Tunneling SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial

More information

PERMEABLE INTERLOCKING CONCRETE PAVEMENT

PERMEABLE INTERLOCKING CONCRETE PAVEMENT [NOTE TO SPECIFICATION WRITER: This guide specification for the use of permeable interlocking concrete pavers for pedestrian and vehicular traffic application was developed based on the use of an open-graded

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,

More information

SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications describes construction of permeable interlocking concrete

More information

Chapter 3 Pre-Installation, Foundations and Piers

Chapter 3 Pre-Installation, Foundations and Piers Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory

More information

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary

More information

Lighthouse Engineering, L.L.C.

Lighthouse Engineering, L.L.C. Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: Office@LighthouseEng.com Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering

More information

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

GRADATION OF AGGREGATE FOR CONCRETE BLOCK GRADATION OF AGGREGATE FOR CONCRETE BLOCK Although numerous papers have been written concerning the proper gradation for concrete mixes, they have generally dealt with plastic mixes, and very little published

More information

SECTION 02795 UNI PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SECTION 02795 UNI PERMEABLE INTERLOCKING CONCRETE PAVEMENT SECTION 02795 UNI PERMEABLE INTERLOCKING CONCRETE PAVEMENT Note: This guide specification is intended for use in the U.S. It describes construction of permeable interlocking concrete pavers on a permeable,

More information

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety

More information

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering Geotechnical Bulletin GB 1 PLAN SUBGRADES Geotechnical Bulletin GB1 was jointly developed by the Offices

More information

SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) SECTION 32 14 13.19 PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795) Note: This guide specification for U.S. applications describes construction of permeable interlocking concrete

More information

Precast Modular Block (PMB) for Retaining Wall Systems

Precast Modular Block (PMB) for Retaining Wall Systems Precast Modular Block (PMB) for Retaining Wall Systems Field Installation Best Practices Manual TABLE OF CONTENTS INTRODUCTION 3 DEFINITIONS 3 CONSTRUCTION RESPONSIBLILITES 4 Precast Retaining Wall Dealer

More information

Designed and Engineered to Perform

Designed and Engineered to Perform History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the

More information

INSTALLATION SPECIFICATIONS FOR AQUAPERM TM PAVER

INSTALLATION SPECIFICATIONS FOR AQUAPERM TM PAVER INSTALLATION SPECIFICATIONS FOR AQUAPERM TM PAVER Applicable to all AquaPerm TM Permeable Unit Paver Systems FOREWORD These outline specifications have been prepared for the general guidance of architects,

More information

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL. STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill

More information

The Verdura Wall check with your local building department

The Verdura Wall check with your local building department The Verdura Wall The Verdura Wall by Soil Retention Products, Inc of Carlsbad, California can be constructed as a gravity retaining structure or a geosynthetic reinforced segmental retaining wall, depending

More information

SECTION 311 PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE

SECTION 311 PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE 311.1 DESCRIPTION: This item shall consist of a cement treated subgrade base course composed of a mixture of local soil, portland

More information

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified. Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

More information

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements 16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information

SECTION 32 1816 PLAYGROUND SURFACING TILES

SECTION 32 1816 PLAYGROUND SURFACING TILES SECTION 32 1816 PLAYGROUND SURFACING TILES PART 1 GENERAL 1.01 SECTION INCLUDES A. Resilient playground safety surfacing tiles. B. Coordinate with work shown in other sections so the work is installed

More information

SECTION 02400 - STORM DRAIN SYSTEM

SECTION 02400 - STORM DRAIN SYSTEM SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And

More information

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown

More information

Guide for SOLID CONCRETE BLOCK SEALS

Guide for SOLID CONCRETE BLOCK SEALS Guide for SOLID CONCRETE BLOCK SEALS July, 2006 Mine Safety and Health Administration SOLID CONCRETE BLOCK SEAL Formersection 30 CFR 75.335(a)(1) specifies requirements for seals constructed using solid

More information

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY Approved and adopted as Official Document Number 800576 this 10th day of December, 1980 Donald R. Boyd, P.E., Director Water

More information

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions. SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings

More information

DESIGN GUIDELINES FOR EARTH RETENTION

DESIGN GUIDELINES FOR EARTH RETENTION DESIGN GUIDELINES FOR EARTH RETENTION Strata Systems, Inc. 380 Dahlonega Rd., Suite 200 Cumming, GA 30040 USA www.geogrid.com TABLE OF CONTENTS MECHANICS OF RETAINING WALLS... 3 THE STRATAWEB SOLUTION...4

More information

Acceptance Codes APPENDIX - A. Acceptance Criteria

Acceptance Codes APPENDIX - A. Acceptance Criteria 1111 Receipt of a satisfactory Test Report from WSDOT Materials Laboratory is required indicating the lot (or lots) or batch of material meets the requirement of the specifications under which it is listed.

More information

DENVER MODEL 30 X 30 SPECIFICATIONS

DENVER MODEL 30 X 30 SPECIFICATIONS DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

SECTION 02530 STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.

SECTION 02530 STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250. 02530-1 of 5 SECTION 02530 STORM DRAINAGE STRUCTURES 02530.01 GENERAL A. Description Storm drainage structure construction shall include, but not necessarily be limited to, furnishing and installing or

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

Stormwater/Wetland Pond Construction Inspection Checklist

Stormwater/Wetland Pond Construction Inspection Checklist : Construction Inspection ChecklistsTools Stormwater/Wetland Pond Construction Inspection Checklist Project: Location: Site Status: Date: Time: Inspector: SATISFACTORY/ UNSATISFACTORY COMMENTS Pre-Construction/Materials

More information

SECTION 32 14 00 PERVIOUS INTERLOCKING CERAMIC PAVERS

SECTION 32 14 00 PERVIOUS INTERLOCKING CERAMIC PAVERS SECTION 32 14 00 PERVIOUS INTERLOCKING CERAMIC PAVERS Pervious interlocking pavers.doc Note: This guide specification for U.S. applications describes construction of permeable interlocking ceramic pavers

More information

PVC PIPE PERFORMANCE FACTORS

PVC PIPE PERFORMANCE FACTORS PVC PIPE PERFORMANCE FACTORS PVC pipe, like all flexible pipe products, is very dependent on the surrounding soil for its structural capacity, in addition, the pipe material must have sufficient inherent

More information

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE FORM A PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE The following suggested specifications are written as a guide to assist the specifier in writing his own specifications. Specific circumstances

More information

SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS

SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING

More information

The Manitoba Water Services Board SECTION 022180 Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11

The Manitoba Water Services Board SECTION 022180 Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11 Page 1 of 11 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the excavation of trenches (or excavation of tunnels); the supply and placing of bedding and backfill materials;

More information

COLORADO MODEL. 35 x 65 SPECIFICATIONS

COLORADO MODEL. 35 x 65 SPECIFICATIONS COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square

More information

SECTION 02401 SHEETING, SHORING AND BRACING

SECTION 02401 SHEETING, SHORING AND BRACING SECTION 02401 SHEETING, SHORING AND BRACING This section should be edited to reflect soil conditions specific to the project site and the recommendations of a Geotechnical Engineer licensed in the State

More information

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio Seven Easy Steps to Installing Your Own Walkway, Driveway and Patio Without Mortar or Concrete Brick is one of the world s oldest and most enduring building materials. Those same qualities also make it

More information

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration

More information

High Strain Dynamic Load Testing of Drilled Shafts

High Strain Dynamic Load Testing of Drilled Shafts Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain

More information

Installation Guidelines for Segmental Block Wall. Contents 1. INTRODUCTION... 2 2. MATERIALS... 2

Installation Guidelines for Segmental Block Wall. Contents 1. INTRODUCTION... 2 2. MATERIALS... 2 Johannesburg +27 (0)11 922 3300 Pinetown +27 (0)31 717 2300 Cape Town +27 (0)21 531 8110 East London +27 (0)43 727 1055 www.kaytech.co.za Installation Guidelines for Segmental Block Wall Contents 1. INTRODUCTION...

More information

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional

More information

Pavement Thickness. esign and RCC-Pave Software. Roller-Compacted Concrete Pavement: Design and Construction. October 24, 2006 Atlanta, Georgia

Pavement Thickness. esign and RCC-Pave Software. Roller-Compacted Concrete Pavement: Design and Construction. October 24, 2006 Atlanta, Georgia Roller-Compacted Concrete Pavement: Design and Construction Pavement Thickness esign and RCC-Pave Software Gregory E. Halsted, P.E. Pavements Engineer Portland Cement Association October 24, 2006 Atlanta,

More information

6 RETROFITTING POST & PIER HOUSES

6 RETROFITTING POST & PIER HOUSES Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This

More information

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS TABLE OF CONTENTS 2.18 CONCRETE AND/OR CORRUGATED STEEL STORM SEWER... 1 2.18.1 GENERAL... 1 2.18.2 MATERIALS... 1 2.18.2.1 Storm Sewer Pipe... 1 2.18.2.2 Cement Mortar... 1 2.18.2.3 Granular Materials...

More information

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND.

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION 623.10 CONCRETE BONDING COMPOUND. 623.10.1 Description. This work shall consist of preparing the surface,

More information

Section 02702 SEWER PIPE INSTALLATION AND TESTING

Section 02702 SEWER PIPE INSTALLATION AND TESTING PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete

More information

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use

More information

Section 402. STORM SEWERS

Section 402. STORM SEWERS 402.02 Section 402. STORM SEWERS 402.01. Description. This work consists of constructing storm sewers of the size and class required, including excavation, bedding, and backfill. 402.02. Materials. Provide

More information

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS

CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations

More information

APPENDIX G SETTLEMENT

APPENDIX G SETTLEMENT APPENDIX G SETTLEMENT TABLE OF CONTENTS G.1 IN T R O D U C T IO N... 1 G.2 MATERIAL PLACEMENT AND COMPACTION... 1 G.2.1 Incom pressible M aterials... 1 G.2.2 Compressible Materials... 2 G.2.3 Soil P lacem

More information

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing 1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

SECTION 32 32 15-1 PRECAST MODULAR BLOCK GRAVITY RETAINING WALL

SECTION 32 32 15-1 PRECAST MODULAR BLOCK GRAVITY RETAINING WALL SECTION 32 32 15 PART 1 GENERAL 1.01 SUMMARY A. This Section includes furnishing all materials and labor required for the design and construction of a precast concrete modular block (PMB) retaining wall

More information

LAYING BLOCK AND BRICK

LAYING BLOCK AND BRICK LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct

More information

GUIDE SPECIFICATIONS FOR CONSTRUCTION OF AQUAPAVE PERMEABLE STORMWATER MANAGEMENT SYSTEM

GUIDE SPECIFICATIONS FOR CONSTRUCTION OF AQUAPAVE PERMEABLE STORMWATER MANAGEMENT SYSTEM GUIDE SPECIFICATIONS FOR CONSTRUCTION OF AQUAPAVE PERMEABLE STORMWATER MANAGEMENT SYSTEM SECTION 32 14 13.19 AquaPave Permeable Interlocking Concrete Pavement Note: This guide specification is for the

More information

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated. CAST IN PLACE DETECTABLE/TACTILE WARNING SURFACE TILE PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Special Conditions and Division 1 Specifications

More information

For the purposes of this Part, the following words shall have the following meanings:

For the purposes of this Part, the following words shall have the following meanings: LOUISIANA REVISED STATUTES TITLE 51. TRADE AND COMMERCE CHAPTER 2. PARTICULAR GOODS PART XIV-B. MINIMUM STANDARDS FOR INSTALLATION OF MANUFACTURED HOMES Current through all 2010 Regular Session Acts 912.21.

More information

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS Chapter 11 Slope Stabiliza bilization and Stability of Cuts and Fills THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS are 1) to create space for the road template and driving surface; 2) to balance material

More information

TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL

TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL SCOPE This section of the specifications includes requirements for the Slurry Trench Cutoff Wall and related work as indicated on the

More information

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE 6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction

More information

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline

More information

Stabilenka HUESKER. and Separation. Engineering with Geosynthetics SKER HUESKER HUESKER HUESKER HUESKERHUES

Stabilenka HUESKER. and Separation. Engineering with Geosynthetics SKER HUESKER HUESKER HUESKER HUESKERHUES HUESKER Engineering with Geosynthetics rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr rhuesker HUESKER Woven HUESKER HUESKER Fabrics HUESKER HUESKERr SKER HUESKER HUESKER HUESKER HUESKERHUES rhuesker

More information

Technical Notes 3B - Brick Masonry Section Properties May 1993

Technical Notes 3B - Brick Masonry Section Properties May 1993 Technical Notes 3B - Brick Masonry Section Properties May 1993 Abstract: This Technical Notes is a design aid for the Building Code Requirements for Masonry Structures (ACI 530/ASCE 5/TMS 402-92) and Specifications

More information

Construction Specification for Concrete Curb and Concrete Curb and Gutter

Construction Specification for Concrete Curb and Concrete Curb and Gutter Engineering & Construction Services Division Standard Specifications for Road Works TS 3.50 April 2015 for Concrete Curb and Table of Contents TS 3.50.01 SCOPE... 3 TS 3.50.02 REFERENCES... 3 TS 3.50.03

More information

Specification for Cast-in-Place Concrete Pipe

Specification for Cast-in-Place Concrete Pipe ACI 346-01 Specification for Cast-in-Place Concrete Pipe Reported by ACI Committee 346 Eric T. Moran Chairman Curtiss W. Gilley Secretary James B. Bennett Gordon Bluth Robert G. Gofonia Alfred L. Kaufman,

More information

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT City of Swartz Creek 8083 Civic Drive Swartz Creek, MI 48473 810-635-4464 Fee Received: $ Date: / / Receipt No: Demolition Permit (including Right of

More information

NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE NAPCA BULLETIN 18-99 APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE GENERAL a. These specifications may be used in whole or in part by any party without

More information

SECTION 32 32 16 PRECAST MODULAR BLOCK RETAINING WALL

SECTION 32 32 16 PRECAST MODULAR BLOCK RETAINING WALL SECTION 32 32 16 PART 1 GENERAL 1.01 SUMMARY A. This Section includes furnishing all materials and labor required for the design and construction of a precast concrete modular block (PMB) retaining wall

More information

San Antonio Water System Standard Specifications for Construction ITEM NO. 1103 POINT REPAIRS AND OBSTRUCTION REMOVALS

San Antonio Water System Standard Specifications for Construction ITEM NO. 1103 POINT REPAIRS AND OBSTRUCTION REMOVALS ITEM NO. 1103 POINT REPAIRS AND OBSTRUCTION REMOVALS 1103.1 DESCRIPTION: 1. Repair of sanitary sewer lines by replacing short lengths of failed pipe with new pipe. 2. Repair of service laterals located

More information