Usage Scenario 2 A simple setup for 8 light channels adding control from 3 rd party toggle switches Interface 3 rd Party Toggle Switches As per Usage
|
|
- Harvey Stuart Spencer
- 7 years ago
- Views:
Transcription
1 Usage Scenario 1 A simple setup for 8 light channels Interface Control4 is used to control 8 separate circuits of lighting using one Control4 DIN Rail 8 x 2A Leading Edge Dimmer Module. Each circuit can be controlled via the Control4 Navigator user interface and/or remote controls. A Control4 HC300 or Control4 I/O Extender sends commands to the DIN Rail Dimmer Module via a serial connection to a Control4 DIN Rail Interface. This device converts the protocol commands before forwarding them to the DIN Rail Dimmer Module on the data bus. power (240VAC) is wired directly into the Control4 DIN Rail 8 x 2A Leading Edge Dimmer Module and Control4 DIN Rail. One DIN Rail must be present on the data bus to provide power for bus and the internal electronics of any DIN Rail Dimmer Modules.
2 Usage Scenario 2 A simple setup for 8 light channels adding control from 3 rd party toggle switches Interface 3 rd Party Toggle Switches As per Usage Scenario 1, but with the addition of a Control4 DIN Rail Module on the data bus. In this scenario each circuit can be controlled via a standard 3 rd party toggle switch, as well as the Control4 Navigator user interface and/or remote controls. Eight standard 3 rd party light switches have been connected to the Module as volt-free contacts. Control4 has been programmed with Composer to toggle a corresponding channel on the DIN Rail Dimmer Module on/off when each of the 3 rd party light switches is pressed. (Alternatively, Control4 could be programmed to activate a lighting scene, involving multiple channels on the DIN Rail Dimmer Module simultaneously, when a 3 rd party light switch is pressed.)
3 Usage Scenario 3 A setup for 8 light channels adding control from 3 rd party toggle switches and Network Processor Unit Interface Network Processor Unit C4 DR NPU M 3 rd Party Toggle Switches As per Usage Scenario 2, but with the addition of a Control4 DIN Rail Network Processor Unit. In this scenario each circuit can be controlled via the 3 rd party Keypads, as well as from the Control4 Navigator user interface and/or remote controls. The 3 rd party Keypads can communicate with the Control4 DIN Rail Network Processor Unit on the data bus, as well as the Control4 Director. The Control4 DIN Rail Network Processor Unit has been programmed independently of Composer, via its own web interface, to allow the 3 rd party Keypads to continue controlling the Control4 DIN Rail 8 x 2A Leading Edge Dimmer Module in the event of the Control4 Director being offline.
4 Usage Scenario 4 A setup for 20 light channels Interface 4 x 3A Dimmer Module C4 DR DIM4 M Control4 is used to control 20 separate circuits of lighting using two Control4 DIN Rail 8 x 2A Leading Edge Dimmer Modules and a Control4 DIN Rail 4 x 3A Leading Edge Dimmer Module. Each circuit can be controlled via the Control4 Navigator user interface and/or remote controls. A Control4 HC300 or Control4 I/O Extender sends commands to the DIN Rail Dimmer Module via a serial connection to a Control4 DIN Rail Interface. This device converts the protocol commands before forwarding them to the DIN Rail Dimmer Module on the data bus. power (240VAC) is wired directly into the Control4 DIN Rail Dimmer Modules and Control4 DIN Rail Power Supply. One DIN Rail must be present on the data bus to provide power for bus and the internal electronics of any DIN Rail Dimmer Modules.
5 Usage Scenario 5 and low voltage device control Interface 4 x 5A Relay C4 CR RM4 M Low Voltage devices: Blinds, PIR s, Doorbell etc 0/1 10V LEDs, DSI or DMX loads Voltage: Garage Door Driveway Heater Extractor Fan Magnetic Lock etc. A Control4 HC300 or Control4 I/O Extender sends commands to a Control4 DIN Rail Module and a Control4 DIN Rail 4 x 5A Relay Module via a serial connection to a Control4 DIN Rail Interface. This device converts the protocol commands before forwarding them to the DIN Rail Modules on the data bus. Each device can be controlled via the Control4 Navigator user interface and/or remote controls. In this scenario the Control4 DIN Rail Module is being used to control 0/1-10V SELV devices, DSI and DMX loads and for the integration of 0-10V signals or conventional contact switches. The Control4 DIN Rail 4 x 5A Relay Module is relaying mains voltage to devices that require 240V.
Basics of Dimming. ISC Learning Centre
ISC Learning Centre July 2009 > Dimmers Contents What is a dimmer? Dimmers & customer benefits Dimmers at home Dimmers at the office Dimmers: technical choices Overview of the Schneider Electric offer
More informationcontents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control
Wireless Control Systems Accessories Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Accessories Programming Switching & Dimmer Functions
More informationDALIX PROGRAMMING MANUAL. Gateway KNX-DALI V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com
Gateway KNX-DALI DALIX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com
More informationKNX Lighting Control System
KNX Lighting Control System Part 1 - Specification Lighting control system A. The following specification details the minimum standards for performance of components, material and operation of lighting
More informationT O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module
T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L Dimmer Module General The Dimmer Pack can be used with any of Tokistar s LED Lighting Systems operating from our 6, 8 or VDC LED Drivers.
More informationTHE INPUT/OUTPUT SYSTEM. Key Points
M O D U L E T W O THE 2 INPUT/OUTPUT SYSTEM Key Points In the first module, you learned about the basic architecture and operation of the Allen-Bradley Micrologix 1000, including a brief introduction to
More informationInstallation and User Guide
Installation and User Guide 458-UNI8 8-Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8-channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either
More informationThe ABB i-bus KNX Room Master Concept Your first step into the KNX world
The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,
More informationGLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS- - - - - - SpaceBuild Specification Worksheet. Touch Screens
SpaceBuild Specification Worksheet GLPHASE System The GLPHASE SpaceBuilder system is ideal for medium-sized spaces that require additional options such as expansion modules for more load types, touch screens,
More informationSuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev: 5-16-14 1
SuperIOr Controller The SuperIOr Controller is a game changer in the world of high speed embedded control. The system combines incredible speed of both control and communication with revolutionary configurable
More informationThe Access Engine. Building Integration System - The Access Engine. Security Systems
The Access Engine 1 What is BIS Access Engine? It is one of the central software modules of the Building Integration System It s a fully integrated access control solution with corresponding access hardware
More informationEKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch
Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com
More informationRako Lighting Driver. For use with: Driver software written and provided by:
Rako Lighting Driver For use with: Driver software written and provided by: Introduction This document is a guide to integrating a Rako Lighting system with an RTI control system, via a Rako Ethernet bridge.
More informationIntroduction to Electronic Signals
Introduction to Electronic Signals Oscilloscope An oscilloscope displays voltage changes over time. Use an oscilloscope to view analog and digital signals when required during circuit diagnosis. Fig. 6-01
More informationRadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! 6.4.200 RadioRA2 Inclusive Software v5.0.8 or newer
Manufacturer: Model Number(s): Minimum Core Module Version: Comments: Lutron Document Revision Date: 8/5/2013 OVERVIEW AND SUPPORTED FEATURES Integration Note RadioRA 2 (QS) Lighting and Climate Control
More informationApplied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
More informationSMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
More informationDMX2PWM 9 Channel Dimmer Setup Manual
DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4
More informationA+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
More informationDigidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide
Digidim 458/DIM8 8-Channel Dimmer Module Installation and User Guide Introduction The 458/DIM8 is an 8-channel digital thyristor dimmer module, for leading-edge dimming of resistive and inductive loads.
More informationLGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationControl Interfaces. GRAFIKR Systems. 369-564a 1 10.25.11 LUT-DMX
369-564a 1 10.25.11 DMX 512 Control Interface Description Allows GRAFIK EyeR lighting controls to operate lighting and other equipment that uses the DMX 512 protocol, including: - Strobes, fiber optic
More informationSimplify Data Acquisition with a Built-in LXI Web Server
M E A S U R E M E N T T I P S Volume 9, Number 3 Simplify Data Acquisition with a Built-in LXI Web Server Snapshot: Make temperature measurements quickly and easily There are many applications in which
More informationSpecifications for EM223 24 VDC 4 In/4 Out and EM223 24 VDC 4 In/4 Relay Out
SIMATIC S7-200 EM223 Digital Combination Modules EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out Table 1 Specifications for EM223 2 VDC In/ Out and EM223 2 VDC In/ Relay Out EM223 2VDC In/Out 6ES7 2231BF200XA0
More informationSECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationSupplemental User Guide
Supplemental User Guide SUPPLEMENTAL GUIDE FOR UPDATG FIRMWARE ON Z-MAX TM LIGHTG CONTROL RELAY PANELS WITH MASTER CONTROL MODULE Software revision.00 an up LIT-ZMAXS-00 Rev A, August 2004 Technical Services:
More informationProduct Name LED Panel light Product Models
R Product Name LED Panel light Product Models MacoLEDs Panel-015 100W MacoLEDs Panel-015 100C Manual No:540-F690-10w MACOSTAR HONG KONG LTD 2/F.,Union Industrial Bldg.,48 Wong Chuk Hang Road,Hong Kong.
More informationHome Monitoring and Control service provided by Verizon Online LLC
Home Monitoring and Control service provided by Verizon Online LLC A separate subscription to Verizon FiOS TV is required for use with FiOS TV service. About This Manual This manual is designed for online
More informationOverview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected
Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara
More informationChapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationUSER MANUAL FOR DRIVER RTI & HDL. Driver User Guide January 2016. Index. 1 Overview... 3 2 Driver Option... 3
Driver User Guide January 2016 Index 1 Overview... 3 2 Driver Option... 3 1 3 Supported IP Gateway Types... 3 4 Supported data Types.....4 5 Configure System Settings... 5 6 Configure General Settings...
More informationDigital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
More informationApplication Unit, MDRC AB/S 1.1, GH Q631 0030 R0111
, GH Q631 0030 R0111 SK 0010 B 98 The application unit is a DIN rail mounted device for insertion in the distribution board. The connection to the EIB is established via a bus connecting terminal at the
More informationDC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
More informationDURACION EN MINUTOS CATEGORIA SUB-CATEGORIA NOMBRE DEL CURSO. Integración con 3ros
Integración con 3ros AMC 60 Atlona 18 Baldwin/Kwikset Locks 96 Blackwire Designs 60 Card Access 60 Channel Vision 30 Dune Media Players 60 Eragy 60 Extra Vegetables 120 Forge Rack Products 15 Fusion Research
More informationInwall 4 Input / 4 Output Module
Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...
More informationProgettare per il Solid State Lighting: le sfide da superare
Progettare per il Solid State Lighting: le sfide da superare Power supply - Photometry Remote Control Dott. Ing. Stefano Scalzi stefano.scalzi@torand.it www.torand.it Company introduction Target markets
More informationMY HOME - CONTROL 130
130 MY HOME - CONTROL SECTION CONTENTS 132 General features 142 Catalogue My home control 131 MY HOME GUIDE PROJECT AND INSTALLATION MY HOME control The home management and control from distance As well
More informationEBDSPIR-DD, EBDSPIR-DD-IP
Product Guide EBDSPIR-DD, EBDSPIR-DD-IP Ceiling PIR presence detector DALI / DSI dimming Overview The EBDSPIR-DD PIR (passive infrared) presence detector provides automatic control of lighting loads with
More informationLED light control using DMX512 control method
LED light control using DMX512 control method June 2011 Why intelligent control? Different needs for control Energy saving Dimming according to natural light, on-off according to room occupancy, for example
More informationMicroMag3 3-Axis Magnetic Sensor Module
1008121 R01 April 2005 MicroMag3 3-Axis Magnetic Sensor Module General Description The MicroMag3 is an integrated 3-axis magnetic field sensing module designed to aid in evaluation and prototyping of PNI
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationNETWORKS Controller Area Network (CAN)
SEC TION 2 : DOMEST I C GMLAN Overview GMLAN is the General Motors variation of the CAN Bus. Although it is CAN based, there are enough proprietary features and functions to make this a unique protocol.
More informationService & Support. Higher-level safe switch-off of the power supply of functionally nonsafe standard modules? Wiring Examples.
Higher-level safe switch-off of the power supply of functionally nonsafe standard modules? Wiring Examples FAQ October 2009 Service & Support Answers for industry. Question This entry is from the Service&Support
More informationLED DIMMING A HELPFUL GUIDE...
LED DIMMING A HELPFUL GUIDE... Introduction There are five types of dimming control interfaces described in this document: 2-Wire Forward Phase, 2-Wire Reverse Phase, 3-Wire (Lutron), 4-Wire (0 10V), and
More informationscalability interoperability modularity 458 Architectural Lighting Control People Innovations Solutions
scalability interoperability modularity 458 Architectural Lighting Control People Innovations Solutions scalability interoperability modularity Conran & Partners architects Architectural lighting requires
More informationDesign and Development of SMS Based Wireless Home Appliance Control and Security System
Journal of Modern Science and Technology Vol. 3. No. 1. March 2015 Issue. Pp.80-87 Design and Development of SMS Based Wireless Home Appliance Control and Security System Md. Abdullah Al Asad *, Md. Al
More informationSOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING
AUTOMATION SYSTEM Catalogue SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING automation system Contents 4-11 Catalogue Control devices 4 Sensors 5 Modular controllers 6 False ceiling controllers and Automation
More information2. DESIGN REQUIREMENTS
2. DESIGN REQUIREMENTS The Smart Lock Security system will give the user the ability to control his or her door lock from the convenience of texting from the user s cell phone. The device can be controlled
More informationGLPAC-DIMFLV Crestron Green Light Integrated Lighting System
> > Up to 8 channels of 0-10 Volt dimming control > > Works in 100 to 277 VAC systems > > 16-Amp load rating per channel > > Built-in Control System with Cresnet and Ethernet port > > UL924 compliant emergency
More informationDMX512 Switch (stand alone mode) DALI Touch Dimmer Switch
0 DMX Switch (stand alone mode) DAI Touch Dimmer Switch 78.9 70. 8.. Comply to standard protocol DMX(990) and in compliance with DMX products from other international incorporations. DMX address is manual
More informationABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC 514 049 N0202, page 1
ABB i-bus KNX Room Solutions 2CDC 514 049 N0202, page 1 Room Master RM/S x.1 The Room Master RM/S 1.1 and RM/S 2.1 offers smart home and intelligent building control for hotel rooms and apartments Modern
More informationMGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders
MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders General The MGL Avionics CAN bus interface for the Trig Avionics TT21 and TT22 transponders provides a simple solution to allow any
More informationChapter 9 N.C. C. N.O. Single-Pole Double-Throw
rather than providing multiple choices. The sensor modules used may only be suitable for use with the matching controller so it is wise to read the specifications to make sure the unit suits your application.
More informationProgramming Manual DDP ( Dynamic Display Panel )
2012 Programming Manual DDP ( Dynamic Display ) V 2.1 Created By Sameh and Basem Contents 1-Introduction Objective 1-1 S-bus products 1-2 2- Start Programming S-Bus Programming Software overview 2-1 S-bus
More informationWireless electroinstalation. www.inels.cz. Product ranges
Product ranges 1 History: 2008: Launch of the RF Control system 2009: RF Control & Oasis compatible 2010: RF Touch introduced 2011: RF Pilot available 2012: elan-rf-003 started to be sell 2013: inels Home
More informationVX 2400 Dimmer User's Manual
TM VX 2400 Dimmer User's Manual 21-2119C Manual Revision 1.01 Software Version 1.0 10 March 1994 Table of Contents 1. General Description...3 1.1. Standard Features:...3 2. Installing Options...4 2.1.
More informationABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
More informationM O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System
V RICONTROL M O N I T O R I N G S O L U T I O N S TM INFRASTRUCTURE MANAGEMENT SOLUTIONS Varicontrol-P The Integrated Rack Management System CONTROLLERS Varicontrol-P2, Varicontrol-P4 and Varicontrol-P6
More informationINTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME. Ján Cigánek, Martin Janáček, Stanislav Števo
INTELLIGENT BUILDINGS BUS SYSTEMS, MyHOME Ján Cigánek, Martin Janáček, Stanislav Števo Slovak University of Technology Ilkovičova 3, 812 19 Bratislava, Slovak Republic Tel.: +421 2 60291111 Fax: +421 2
More informationUser Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
More informationDIGITAL CONTROLS OVERVIEW
DIGITAL CONTROLS OVERVIEW START Phase Cutting Dimmers Analogue Dimming switchdim corridorfunction DSI Dimming Dali Dimming Dali-Ag PIR Wiring Diagram s Wiring Diagram s Wiring Diagram s Wiring Diagram
More informationRGB for ZX Spectrum 128, +2, +2A, +3
RGB for ZX Spectrum 128, +2, +2A, +3 Introduction... 2 Video Circuitry... 3 Audio Circuitry... 8 Lead Wiring... 9 Testing The Lead... 11 Spectrum +2A/+3 RGB Differences... 12 Circuitry Calculations...
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
More informationElectrical Symbols and Line Diagrams
Electrical Symbols and Line Diagrams Chapter 3 Material taken from Chapter 3 of One-Line Diagrams One-line diagram a diagram that uses single lines and graphic symbols to indicate the path and components
More informationNSI DDR DIMMING RACK POWER DISTRIBUTION UNIT
Main Power Connections NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT Camlok style "J" series connectors are for connection of up to a 300 Amp 120/240 VAC or 120/208 VAC electrical service. These connections
More informationABB i-bus KNX Switch Actuators SA/S Product Information
ABB i-bus KNX Switch Actuators SA/S Product Information ABB Stotz-Kontakt GmbH Your Partner with Know-How for Future-Oriented Electrical Installation Hugo Stotz, the company founder of ABB Stotz-Kontakt,
More informationModbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
More informationLynx Touch L5100 Technical Training. Z-Wave Setup
Lynx Touch L5100 Technical Training Z-Wave Setup L5100-Z-wave Combines Home Automation and Security Controls up to: - 40 Devices (Lights, switches and lamp modules) - 3 Thermostats - 4 Door Locks Rules
More informationInstallation and Operating Instructions
General The INSTABUS DALI gateway brings the lighting control specfic DALI-Bus and the pluridisciplinary and cross-functional EIB/KNX bus together. Cost effective DALI ECGs can therefore be seamlessly
More informationIntelligent Home Automation and Security System
Intelligent Home Automation and Security System Ms. Radhamani N Department of Electronics and communication, VVIET, Mysore, India ABSTRACT: In todays scenario safer home security is required, As the technology
More informationTebis application software
Tebis application software Input products / ON / OFF output / RF dimmer Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices WYC81xQ
More informationData Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control
More informationProduct data base 2.63 (ETS2 1.2 ETS3.0c / vd2-file) Instabus KNX/EIB System
Audio Audio actuator 4fold 0531 00 Audio actuator 4fold Audio actuator mono Audio actuator stereo Communication Infrared 0588.. IR converter IR transmission/reception C00701 Radio 0868 00 Radio-instabus
More informationELM Security System Electronic Locking & Monitoring
Whitepaper ELM Security System Electronic Locking & Monitoring Issue: September 2006 EMKA Beschlagteile GmbH & Co.KG Release: 1.0 Langenberger Str. 32 42551 Velbert Germany Tel.: 0049 (0) 20 51 / 2 73-0
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More informationLighting Control Overview
Overview Lighting Control Overview RTC Inbuilt real time clock Automatic daylight savings adjustment Atomic clock synchronisation (NTS). Triggers Inputs Schedules Network Conigurable inputs with dynamic
More informationyour home in your hand
your home in your hand Product sheet Summary With xxter you can control your automated home installation with your iphone, ipad, ipod touch or Android device. It is exceptionally easy to use, for both
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationCruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
More informationHOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW
OVERVIEW The purpose of this this specification document is to define the main features and guide lines for the Hotel Room Management System, which includes Access Control, Guest Management, & Building
More informationSmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings
Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...
More informationMH - Gesellschaft für Hardware/Software mbh
E.d.a.s.VX Data acquisition on board road and track vehicles The E.d.a.s.VX System is designed for portable applications running on 12 Volts DC, and is capable of measuring at selectable rates up to 30,000,000
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationLIGHTCOMMANDER II 24/6 LIGHTCOMMANDER II 48/6. User s Manual
LIGHTCOMMANDER II 24/6 LIGHTCOMMANDER II 48/6 User s Manual Version 2.59 August 2007 Table of Contents 0. Introduction... 4 0.1 How to use your Operator s Manual... 4 0.2 Specifications and Installation...
More informationoverview DyNet over RS485
technical guide systems integration overview Integration between various control systems within projects, reduce end-users need to have multiple interactions to perform what seems like one task such as
More informationGSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.1 Date Issued: 2009-12-18. All rights reserved by King Pigeon Hi-Tech. Co., Ltd.
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
More informationChapter 02: Computer Organization. Lesson 04: Functional units and components in a computer organization Part 3 Bus Structures
Chapter 02: Computer Organization Lesson 04: Functional units and components in a computer organization Part 3 Bus Structures Objective: Understand the IO Subsystem and Understand Bus Structures Understand
More informationSmart Thermostat page 1
Smart Thermostat page 1 3. APPROACH In today s home appliances market, automation is becoming the norm and Smart Thermostat is a typical automation appliance able to be applied easily at home. With Smart
More informationTG24 / 48 LIGHTING CONTROLLER
TG24 / 48 LIGHTING CONTROLLER USER MANUAL ( Version: 2.0 ) Net.DO LIGHTING CONTROL EQUIPMENT CO.,LTD Contents 1 Summary... 2 1.1 Function... 2 1.2 Specification parameter... 3 2 Installation... 3 2.1 Safety
More informationMICROCONTROLLER BASED SMART HOME WITH SECURITY USING GSM TECHNOLOGY
MICROCONTROLLER BASED SMART HOME WITH SECURITY USING GSM TECHNOLOGY F. Shawki 1,2, M. El-Shahat. Dessouki 1,3, A. I. Elbasiouny 4, A.N. Almazroui 5, F. M. R. Albeladi 5 1 Assistant Professor, Electrical
More informationProduct Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
More informationIntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
More informationISSN: 2319-5967 ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013
Control4 Smart Home System using Lab VIEW Akshatha N Gowda (1), Girijamba D L (2), Rishika G N (3), Shruthi S D (4),Niveditha S (5) 1,2,3,4 and 5 belongs to Department of Electronics & Communication Engineering
More informationSection 16935 TELEPHONE AUTOMATIC DIALER SYSTEM
Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular
More informationArchitectural Lighting Control System
Architectural Lighting Control System Environ3 architectural lighting control system is a revolutionary networked system of line voltage master keypads, wallbox dimmers, and infrared remotes that provide
More informationTronico Technology Company Limited. First step of IOT - DIY smart home
Tronico Technology Company Limited First step of IOT - DIY smart home What is IOT? 2 The Internet of Things (IoT) is the network of physical objects devices, vehicles, buildings and other items that enables
More informationUsing installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
More information