8901 Access Control Panel Installation Guide

Size: px
Start display at page:

Download "8901 Access Control Panel Installation Guide"

Transcription

1 1. Introduction 2. Technical Specification 3. System Deployment 4. Panel Layout 5. Detailed Pin Assignment 6. Panel Configuration 7. Sample Connection Circuits System Reader Electrical Lock Door Alarm Door Ajar Door Sensor Release Button Panel Tamper Version C Design. Innovations Page 1 of 17

2 1. Introduction This document provides detailed description about the features, functions and setup of ACX 8901 Control Panel. A. Strength Native TCP/IP on board, 10/100Mbps communication speed Flexibility structure cabling, cat 5 cable, direct to hub or panel to panel daisy chain wiring. Multi-threading program, transactions upload to database server less than 2 sec under 50 panels. User defined 128 bits key for the data exchange between ACX 8901&8902 door access panel to ACX COM Server, prevent the real data to be snooped and simulated by other network point. User defined 128 bits key, scramble RS485 data exchange between ACX 8901&8902 door access panel and ACX reader, prevent reader data to be snooped and copied. Work with ACX 2081 I/O module, save the wiring cost and increase the data security (patented design) Support 7 x card number format, each card number format has 3 x facility code checking Work with ACX LCD reader, display interactive message Work with ACX emergency door open device Supervised Monitor of the Door Sensor Input, Prevent trouble close and open B. Features 32 bits microprocessor, 50MHz External device short circuit protection Thumbed protection Recoverable fuse protection. Status LED represents operating status Auto recover for the TCP/IP failure Battery on board for memory retention, 3 years Firmware can be on-line upgraded Real time clock, less than 1 sec deviation daily. Twin card operation (100 couples) Anti-passback Two door interlock Version C Design. Innovations Page 2 of 17

3 C. Panel Appearance Version C Design. Innovations Page 3 of 17

4 2. Technical Specification Specification 8901 Panel Inputs Panel Outputs Memory PCB Dimension Expansion Holidays Timezone - 1 x IN and 1 x OUT Wigand reader or; - 1 x IN and 1 x OUT ACX scramble RS485 reader - 1 x door sensor input - 1 x request to exit input - 1 x auxiliary input - 1 x controller box tamper input - 1 x ACX high security key open door device - Power input monitoring : A.C. / D.C. / Backup Battary - Work with ACX high security door emergency open device, couple with random key switch & reset panel. - 1 x E-Lock relay dry contact output, max. 10A current rating - 1 x Alarm relay dry contact output, max. 3A current rating - 1 x Door ajar TTL signal output, 5VDC output, 20mA VDC battery charging - 38,000 cardholders, each card holder has 24 bytes content - 45,000 swipe card records events 120mm x 120mm x 12mm 1 x RS485 serial port for expansion, software and hardware interface to other system 100 Holiday dates - 80 x access control time zone - 1 x password time zone - 1 x electric Lock time zone - 1 x alarm time zone - 1 x door ajar time zone - 1 x request to exit time zone - 1 x twin card operation time zone All timezone can be assigned from Monday to Sunday and Holiday, 4 intervals per day, time zone can be selected globally or individually Password Communication - User password, timezone control - Global password, key in the password through keypad reader open door - Duress password, open door but trigger alarm output - Panel to hub, CAT 5 cable (max. 100 meters) - Panel to panel, daisy chain by CAT 5 cable (max. 100 meters) Version C Design. Innovations Page 4 of 17

5 No. of Panels Depends on IP address available Backup Battery Operating Voltage Operating Temperature Operating humidity Wiegand Reader - 12VDC, 7AH backup battery, - provide at least 4 hours operation, excludes electric lock power consumption - 220V, 5A input in AC. - 12VDC, 3A output 0 to 65 C 0-95% relative humidity non-condensing - Communication: Wiegand - Green / Red LED control - Buzzer control - Reader in 6 wires connection - Max. cable length : 150m ACX Reader - Communication : RS485 - High Security scramble data encryption - 7 x LED color control - Buzzer Control - Interactive message display for ACX LCD reader - Reader in 4 wires connection - Max. cable length : 1,200m Version C Design. Innovations Page 5 of 17

6 3. System Deployment There are three ways to connect panels. All of the panels communicate in TCP/IP protocol with each other. CAT5 cable is used to connect the panel to the (LAN) Local Area Network or connect the panels in Daisy Chain. RS 485 protocol is no longer used for inter-panel communications so that the cost is reduced and the speed is increased. Multi-threading is also used to speed up concurrent operations. Pier to Pier Daisy Chain Pier to Pier + Daisy Chain Pier to Pier DATABASE and SOFTWARE Local Area Network TCP/IP TCP/IP TCP/IP.... Daisy Chain DATABASE and SOFTWARE Local Area Network TCP/IP TCP/IP.... Version C Design. Innovations Page 6 of 17

7 Pier to Pier + Daisy Chain DATABASE and SOFTWARE Local Area Network TCP/IP TCP/IP.... TCP/IP.... Version C Design. Innovations Page 7 of 17

8 4. Panel Layout ACX 8901 Single Door TCP/IP Panel 120mm C2 C3 C4 C5 C2 : NO / NC / COM / PWR / GND (1) C3 : Door Ajar / NO / NC / COM (1) C4 : Door Sensor / GND / RTE / GND (1) - AUX IN - Tamper 12VDC, 3ADC RJ45 RJ45 120mm C1 2 x Wiegand or ACX Scramble RS485 reader Power / Ground / D0 / D1 / ACK / Buzzer / RS485 T+ / RS485 T- RS485 Port (for future use) For Emergency Door open Device AC / DC / Backup battery monitoring C6 C7 C8 C10 C9 Start from the left is PIN 1 when face the terminal Version C Design. Innovations Page 8 of 17

9 5. Detailed Pin Assignment 8901 Single Door TCP/IP Controller Connector Summary PIN Description C1 C2 C3 C4 C5 C6 C7 C8 Power Input E-Lock Power (12V, 1.5A) E-Lock Output (Dry Contact) Door Alarm Output (Dry Contact) 1 12VDC, 3ADC 1 Ground 2 Power 3 COM 4 NC 5 NO 1 COM 2 NC 3 NO Door Ajar Output 4 Normal is 0VDC, Door Ajar 5VDC, 200mA output Door Sensor Release Button AUX INPUT Panel Tamper RS485 Port (Custom use) For Emergency Door Open Device Power Status 1 Door Sensor 3 Release button 4 Ground 1 IN#1 3 Tamper 4 Ground 1 RS485 (T+) 2 RS485 (T-) 3 RS485 (T+) 4 RS485 (T-) 1 Power Out (12VDC, 100mA) 3 Signal + 4 Signal - 1 DC Power 2 Backup Battery Version C Design. Innovations Page 9 of 17

10 3 A.C. Power 4 Ground 1 Reader Power (200mA) 3 Data 0 4 Data 1 C9 OUT Reader 5 Green LED (ACK) 6 Buzzer 7 RS485 (T+) ACX RS485 reader only 8 RS485 (T-) ACX RS485 reader only 1 Reader Power (200mA) 3 Data 0 4 Data 1 C10 IN Reader 5 Green LED (ACK) 6 Buzzer 7 RS485 (T+) ACX RS485 reader only 8 RS485 (T-) ACX RS485 reader only 1 RJ45 2 Ports TCP/IP Switch Connect to TCP/IP swtich or next Panel 2 Version C Design. Innovations Page 10 of 17

11 6. Panel Configuration Panel Address 1. Go to the IP Config folder under the Installation folder (Normally C:\Program Files (x86)\acx\x.90 Access Control System\Set IP Config). Open the IP Configuration utility program. 2. Click Scan button. 3. Select the device and modify the IP Address or other parameters. Input the PWD and Click Set button to download configuration to the board. Remark: The Default Key is Version C Design. Innovations Page 11 of 17

12 7. Sample Connection Circuits A. System Daisy Chain Hub TCP/IP 8901/8902 Server L A N TCP/IP TCP/IP 8901/ /8902 Version C Design. Innovations Page 12 of 17

13 B. Reader Wire Color: Reader: C9, C10 1. Red Reader Power 2. Black Ground 3. Green Data 0 4. White Data 1 5. Orange Green LED (ACK) 6. Yellow Buzzer 7. Purple RS485 (T+) 8. Grey RS485 (T-) Wiegand Reader Wiegand Reader ACX Scramble RS485 Reader (Improved Security) Scramble RS 485 Reader Version C Design. Innovations Page 13 of 17

14 E-Lock 8901 Access Control Panel Installation Guide C. Electrical Lock Pin Assignment: E-Lock: C2 1 Ground 2 Power 3 COM 4 NC 5 NO + E-Lock - Normally Closed with Power on Panel E-Lock + - Normally Open with Power on Panel External Power Normally Closed with External Power E-Lock + - External Ground External Power Normally Open with External Power + - External Ground Version C Design. Innovations Page 14 of 17

15 D. Door Alarm (Dry Contact) Pin Assignment: Alarm: C3 1 COM 2 NC 3 NO 4 Normal is 0VDC, Door Ajar 5VDC, 20mA output External Power Normally Open with External Power Alarm Device + - External Ground External Power Normally Closed with External Power Alarm Device + - External Ground E. Door Ajar Output Pin Assignment: Door Ajar: C3 1 COM 2 NC 3 NO 4 Normal is 0VDC, Door Ajar 5VDC, 20mA output LED Connect to LED indication Panel Ground Version C Design. Innovations Page 15 of 17

16 F. Door Sensor and Release Button Input Pin Assignment: Door Sensor and Release Button: C4 1 Door Sensor 3 Release button 4 Ground Door Sensor Connect the Sensor Input Release Button G. Panel Tamper Panel Tamper: C5 Pin Assignment: 1 Door Sensor 3 Release button 4 Ground Normal is Close Connect the Sensor Input Version C Design. Innovations Page 16 of 17

17 H. Emergency Door Open Device Pin Assignment: Emergency Door Open: C7 1 Power Out (12VDC, 100mA) 3 Signal + 4 Signal - Install the ACX J1 key switch panel ACX J1 Pin Assignment for Key Switch Pin Type Function Wire Color 1 Red (V-) Red 2 LED Green (V-) Green 3 VCC (12V) Black 4 Key N.O Amber 5 COM (for Key and Tamper) White 6 Tamper N.O Brown S- S+ GND 12V Control Panel C7 for 8901 C10 for 8902 Version C Design. Innovations Page 17 of 17

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc. SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection

More information

HyperAccess Access Control System

HyperAccess Access Control System Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

EMBEDDED ACCESS CONTROL Hardware Installation Guide

EMBEDDED ACCESS CONTROL Hardware Installation Guide EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel

More information

GV- RK1352 Card Reader

GV- RK1352 Card Reader GV- RK1352 Card Reader The GV-RK1352 is a card reader with keypad, designed to recognize PIN codes, identification cards or both. Featured with the Wiegand and RS-485 outputs, the unit can be connected

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

Installation manual. Version 1.1. www.videx-security.com

Installation manual. Version 1.1. www.videx-security.com Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-A

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASHV1124-A-EN 2011 GeoVision, Inc.

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

CKM-EP2500, CKM-EP1501, and CKM-EP1502 Mercury Network Controllers

CKM-EP2500, CKM-EP1501, and CKM-EP1502 Mercury Network Controllers Johnson Controls, Inc. now offers Mercury Security Corporation s high-quality access control hardware products, which can be integrated with the Johnson Controls P2000 Security Management System (SMS)

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

[FAQ] Troubleshooting Access Control Issues

[FAQ] Troubleshooting Access Control Issues [FAQ] Troubleshooting Access Control Issues Article ID: GV4-14-06-16-t Release Date: 06/16/2014 Applied to GV-ASManager GV-AS Controller GV-Reader Summary When you encounter problems with GV-ASManager,

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

INSTALLATION MANUAL XM3 Reader

INSTALLATION MANUAL XM3 Reader INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad) KCIENSBP KCIEN Heavy Duty Stainless Steel Illuminated Keypads Range: DIGICODE (Stand-Alone Keypad) INSTALLATION MANUAL Features: Input voltage: 12V to 24V AC or 12V to 48V DC Illuminated keys Heavy duty

More information

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara

More information

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0)

Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0) Fleets Vehicle GPS Tracker TS20 User Manual (Version 1.0) Index Contents 1. Package Contents... 3 2. Features and Specifications... 3 3. Mechanical Size... 4 4. Knowledge before Usage... 4 4.1 Factory

More information

P10 - Standalone Access Controller and Reader

P10 - Standalone Access Controller and Reader www.quantek.co.uk T: 01246 417113 P10 - Standalone Access Controller and Reader 1 Description & Features: P10 is a waterproof standalone access control, reading EM&HID card, it uses advanced Microprocessor,

More information

www.sebury.com.cn Digital Keypad Use s Manual

www.sebury.com.cn Digital Keypad Use s Manual K3 K4 www.sebury.com.cn Digital Keypad Use s Manual Contents Introduction Introduction Specifications Intramural Interface Circuit 3 Mounting 3 Wiring 5 Power UP 7 Engineer Programming Mode 7 The K3/K4

More information

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT3 Printer Module: ASCII Protocol Programming Instructions PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send

More information

GSM Autodialer Professional GJD700 Speech & Text Autodialer

GSM Autodialer Professional GJD700 Speech & Text Autodialer Text Edit message GSM Autodialer Professional GJD700 Speech & Text Autodialer Introduction The GSM Autodialer Professional works in conjunction with standard alarm systems and makes use of your preferred

More information

User Manual. Before installation and use, please read the user manual carefully.

User Manual. Before installation and use, please read the user manual carefully. Sebury Technology Co., Ltd. Address: 5/F, Building 8, Xinwu Industrial Park, Xili, Nanshan District, Shenzhen, China. Tel: +86-755-88856 Fax: +86-755-888565 P.C.: 58055 www.sebury.com.cn User Manual Before

More information

PROXIMITY CARD READERS C-10, C-20, C60, C70

PROXIMITY CARD READERS C-10, C-20, C60, C70 Installation Manual PROXIMITY CARD READERS C-10, C-20, C60, C70 VERSION 1.0 CONTENTS 1. General information................................. 3 2. Technical data......................... 4 3. Connection

More information

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP

More information

HWg-STE HWg-STE PoE MANUAL

HWg-STE HWg-STE PoE MANUAL HWg-STE HWg-STE PoE MANUAL www.hw-group.com Page 2 HWg-STE connectors LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors.

More information

GSM Voice Auto Dialer & SMS Sender JC-999

GSM Voice Auto Dialer & SMS Sender JC-999 GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C

More information

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) User Manual Table of Contents 1 Introduction 2 General specification 3 Installation 4 Pin assignment & function of connectors 5 Drawing

More information

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry. IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input

More information

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle

More information

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.

More information

USER MANUAL V5.0 ST100

USER MANUAL V5.0 ST100 GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2

More information

Functional Specification Document

Functional Specification Document Functional Specification Document Access Control Technology Unit C1 South City Business Centre Tallaght Dublin 24 Ireland Ph: + 353 (0) 1 4662570 Web: www.accesscontrol.ie Index Introduction 1.1 Hardware

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

UNC500 HARDWARE MANUAL. new generation building security

UNC500 HARDWARE MANUAL. new generation building security UNC500 HARDWARE MANUAL new generation building security Copyright Notice Copyright 1995-2012 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant to an agreement

More information

Fleets Vehicle GPS Tracker TR-11E User Manual (Version 1.0)

Fleets Vehicle GPS Tracker TR-11E User Manual (Version 1.0) Fleets Vehicle GPS Tracker TR-11E User Manual (Version 1.0) Index Contents 1. Introduction:... 3 1.1 Features... 3 1.2 Specification... 3 1.3 Mechanical Size:... 3 2. Knowledge before Usage:... 4 2.1Factory

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS Read carefully

More information

SNMP Web Management. User s Manual For SNMP Web Card/Box

SNMP Web Management. User s Manual For SNMP Web Card/Box SNMP Web Management User s Manual For SNMP Web Card/Box Management Software for Off-Grid Inverter Version: 1.2 Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2 Features... 1 1.3 Overlook...

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever.

Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever. Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever. Expandability is the most important feature of any access

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

AR-721U/721K/661U User s Guide

AR-721U/721K/661U User s Guide AR-72U/72K/66U User s Guide Feb. 6, 2004 Table of Contents Page. Main Feature --------------------------------- 3 2. AR-72U Installation --------------------------------- 4 2. Steps ---------------------------------

More information

9452/9453 Installation and User Guide

9452/9453 Installation and User Guide 9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10 9452/3 Introduction The 9452 and

More information

User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies

User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies Genius GPS / GSM 810 Real Time GPS Tracker User Manual Android App Download Iphone App Download www.geniuscaralarm.com 1 Genius GPS / GSM 810 Real Time GPS Tracker Welcome to use this real time car GPS

More information

AUTODIALLER / QUICKDIALLER - SA132

AUTODIALLER / QUICKDIALLER - SA132 AUTODIALLER / QUICKDIALLER - SA132 INSTRUCTION LEAFLET ENGLISH www.thermomax-group.com CONTENTS 1 SETUP AT A GLANCE... 2 2 FOREWORD....... 3 3 INSTALLATION...... 4 4 KEYPAD AND INDICATORS...... 5 SETTING

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

UPiS - Uninterruptible Power intelligent Supply

UPiS - Uninterruptible Power intelligent Supply UPiS - Uninterruptible Power intelligent Supply www.pimodules.com Introduction The UPiS is an Advanced Powering add-on Module for the RaspberryPi that adds a wealth of additional features to the powering

More information

3.5 EXTERNAL NETWORK HDD. User s Manual

3.5 EXTERNAL NETWORK HDD. User s Manual 3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility

More information

Controller 5000GL Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. GGBUS L LOCAL BUS

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

9448 Installation and User Guide

9448 Installation and User Guide 9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and

More information

The Access Engine. Building Integration System - The Access Engine. Security Systems

The Access Engine. Building Integration System - The Access Engine. Security Systems The Access Engine 1 What is BIS Access Engine? It is one of the central software modules of the Building Integration System It s a fully integrated access control solution with corresponding access hardware

More information

Access Control Unit User s Guide

Access Control Unit User s Guide NetAXS Access Control Unit User s Guide The configurations described in this document have not been reviewed by Underwriters Laboratories Inc. June 2007 2007 Honeywell. All rights reserved. 800-00233,

More information

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation. This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Rev 06 1211. GSM base station. Installation instructions

Rev 06 1211. GSM base station. Installation instructions Rev 06 1211 GSM base station Installation instructions Output string format Baud rate 115200 bps Parity none Data bits 8 Stop bits 1 Flow control none The output string is a modified version of the Sureguard

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

PCS300 Universal IP Reporting Module V1.0

PCS300 Universal IP Reporting Module V1.0 PCS300 Universal IP Reporting Module V1.0 Reference and Installation Manual Patents: One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111,

More information

VTO6xxx. IP door stations. User manual

VTO6xxx. IP door stations. User manual VTO6xxx IP door stations User manual Table of Contents 1 Product Appearance 2 Basic Function Introduction 2.1 Call Manager Center 2.2 Call User 2.2.1 Connecting Status 2.2.2 Calling Status 2.3 Monitor

More information

SHENZHEN PROYU BIOMETRIC T/A & A/C TERMINAL QUOTATION

SHENZHEN PROYU BIOMETRIC T/A & A/C TERMINAL QUOTATION Biometric Time Attendance Terminal ITEM NO. MAIN SPECIFICATION PY-B3 * Fingerprint Cap.: 1,500 * Record Cap.: 50,000 * Communication: RS232;485;TCP/IP * Workcode: * Check in/out, Break in/out PY-X628 *

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

e-ask electronic Access Security Keyless-entry

e-ask electronic Access Security Keyless-entry e-ask electronic Access Security Keyless-entry e-fob Keyless-entry entry System Full-Function Function Installation Manual FCC ID: TV2EFOB1 (UM20 ~ 22793-02) Table of Contents Introduction... 1 e-fob Operation

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions ETHERNET IRRIGATION CONTROLLER Irrigation Caddy Model: ICEthS1 User Manual and Installation Instructions I R R I G A T I O N C A D D Y M O D E L : I C E T H S 1 User Manual and Installation Instructions

More information

Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n

Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n A convenient, new way Since the launch of Keyscan s Centrally Managed Access Control (CMAC), access control

More information

NStar Build 648. Release Notes. Page 1 of 17

NStar Build 648. Release Notes. Page 1 of 17 NStar Build 648 Release Notes Page 1 of 17 This page is left blank intentionally Page 2 of 17 NStar Build 648 Release Notes Release notes NStar Build 648 Overview These release

More information

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version 1.05.00 CX Series Video Recording Server CX784 / CX788 / CX7816 Quick Start Guide Version 1.05.00 Contents 1.Introduction...1 1.1.Packages Contents...1 1.2.Hardware Features...2 1.3.Functional Features...4 1.4.Hard

More information

WIZ-Embedded WebServer User s Manual (Ver. 1.0)

WIZ-Embedded WebServer User s Manual (Ver. 1.0) [텍스트 입력] WIZ-Embedded WebServer User s Manual (Ver. 1.0) 2007 WIZnet Inc. All Rights Reserved. For more information, visit our website at www.wiznet.co.kr Document History Information Revision Data Description

More information

Adaptability to Enhanced Security

Adaptability to Enhanced Security Installer Guide Adaptability to Enhanced Security AdapTec Plus combines power supply and door access controller features in a compact casing for an encrypted and secure I/O function, enhancing door access

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

Waterproof portable tracker and

Waterproof portable tracker and Catalog for GPS tracking system Model Description Picture Mainstream GPS/GSM/GPRS vehicle tracking device, designed as solution for fleet management, which is a GP4000 robust fleet tracking device not

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

TruPortal: Hardware Installation and Software

TruPortal: Hardware Installation and Software TruPortal: Hardware Installation and Software Agenda Hardware Installation Software Installation Day-to-Day Use Basics Day-to-Day Use Advanced 2 April 12, 2012 HARDWARE INSTALLATION 3 April 12, 2012 Learning

More information

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2] SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port

More information

GST301. (Single Protection Zone) Operation Manual

GST301. (Single Protection Zone) Operation Manual GST301 Gas Extinguishing Control Panel (Single Protection Zone) Operation Manual 2 of 19 CONTENTS 1 OVERVIEW... 4 2 TECHNICAL DATA... 4 3 STRUCTURES... 5 3.1 FRONT SURFACE DESCRIPTION... 5 3.1.1 Indicators...

More information

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements This document explains how to setup and use the Allegion AD-400 wireless locks with the NXT Mercury Powered controllers and the Doors.NET software. These locks have extensive functionality and operating

More information

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...

More information

Access Easy Controller 2.1

Access Easy Controller 2.1 Systems Access Easy Controller 2.1 Access Easy Controller 2.1 4 readers expandable to 32 readers Supports up to 20,480 card holders and 100,000 transactions Classify cardholders based on 254 access groups

More information

Product Guide CM-Relay

Product Guide CM-Relay Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL. Overview CM-Relay combines climate monitoring with remote relay

More information

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O

More information

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide About This Guide 3 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers, administrators and integrators who are authorized to configure

More information

GSM Alarm System User Manual

GSM Alarm System User Manual GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM

More information