Fuse base with fusible link
|
|
- George Solomon King
- 7 years ago
- Views:
Transcription
1 Fuse base with fusible link Series 851 Operating instructions Additional languages
2 General Information Contents 1 General Information Manufacturer Information regarding the operating instructions Further documents Conformity with standards and regulations...3 Explanation of the symbols Symbols in these operating instructions...3. Warning notes....3 Symbols on the device... 3 Safety notes Operating instructions storage Safe use Modifications and alterations...5 Function and device design Function Technical data... Transport and storage Mounting and installation Dimensions / fastening dimensions Mounting / dismounting, operating position Electrical Connection Commissioning Maintenance and repair Maintenance Cleaning Maintenance Repair Returning the device Disposal Accessories and Spare parts General Information 1.1 Manufacturer R. STAHL Schaltgeräte GmbH Am Bahnhof Waldenburg Germany Phone: Fax: Internet: info@stahl.de 1. Information regarding the operating instructions ID-No.: 195 / Publication Code: BA00 III en 0 Fuse base with fusible link 195 / Series BA00 III en 0
3 1.3 Further documents Data sheet 851 For further languages, see 1. Conformity with standards and regulations See certificates and EC Declaration of Conformity: Explanation of the symbols.1 Symbols in these operating instructions Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive atmosphere Danger due to energised parts Explanation of the symbols 195 / BA00 III en 0 Fuse base with fusible link Series 851 3
4 Safety notes. Warning notes Warning notes must be observed under all circumstances, in order to minimize the risk due to construction and operation. The warning notes have the following structure: Signalling word:, WARNING, CAUTION, NOTICE Type and source of danger/damage Consequences of danger Taking countermeasures to avoid the danger/damage Danger to persons Non-compliance with the instruction results in severe or fatal injuries to persons..3 Symbols on the device WARNING Danger to persons Non-compliance with the instruction can result in severe or fatal injuries to persons. CAUTION Danger to persons Non-compliance with the instruction can result in light injuries to persons. NOTICE Avoiding material damage Non-compliance with the instruction can result in material damage to the device and / or its environment. Symbol Bedeutung ATEX-Notified Body for Quality Assessment. 1338E00 According to marking, device approved for hazardous areas. 0198E00 Input 159E00 Output 158E00 3 Safety notes 3.1 Operating instructions storage Read the operating instructions carefully and store them at the mounting location of the device. Observe applicable documents and operating instructions of the devices to be connected. Fuse base with fusible link 195 / Series BA00 III en 0
5 Function and device design 3. Safe use Read and observe the safety notes in these operating instructions! Use the device in accordance with its intended and approved purpose only. We cannot be held liable for damage caused by incorrect or unauthorized use or by non-compliance with these operating instructions. Before installation and commissioning, make sure that the device is not damaged. Work on the device (installation, maintenance, overhaul, repair) may only be carried out by appropriately authorized and trained personnel. During installation and operation observe the information (characteristic values and rated operating conditions) on the rating, data and information plates located on the device. Always consult with R. STAHL Schaltgeräte GmbH in case of operating conditions which deviate from the technical data. 3.3 Modifications and alterations Explosion hazard due to modifications and alterations to the device! Non-compliance results in severe or fatal injuries. Do not modify or alter the device. No liability or warranty for damage resulting from modifications and alterations. Function and device design Explosion hazard due to improper use! Non-compliance results in severe or fatal injuries. Use the device only according to the operating conditions described in these operating instructions..1 Function The fuse elements Series 851 safe electric circuits in hazardous areas. They must be installed in an enclosure of type of the protection Ex-e "Increased safety". The fuse element 851/01 is equipped with customary fuse links of the Neozed system and the fuse element 851/0 with customary fuse links of the Diazed system. They are mainly used in Ex-e power distribution boards for protection of consumer terminals. 195 / BA00 III en 0 Fuse base with fusible link Series 851 5
6 Technical data 5 Technical data Marking Type designation 851 Explosion Protection Global (IECEx) Gas IECEx PTB 0.003U Ex d e IIC Gb Ex d e I Mb Europe (ATEX) Gas PTB 0 ATEX 108 U E II G Ex de IIC Gb E I M Ex de I Mb Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), Serbia (SRPS) Technical Data Design 851/01 851/0 Electrical data Rated insulation 550 V 90 V voltage Rated operational voltage 00 V AC, 50 V DC 500 V AC/DC Rated operational current I e D01 1 A, D0 5A Operating class gg gg DII 5 A, DIII 3 A Fuse base with fusible link 195 / Series BA00 III en 0
7 t t Technical Data Current characteristics Ambient conditions Ambient temperature Temperature classes Mechanical data Enclosure material Time/current characteristic of the fuse links (tolerance range max. ± 10%) [s] vs A A A 10 A 13 A 1 A I p [A] -55 C C Epoxy resin 07105E00 851/01 851/0 [s] vs A A A 10 A 1 A 0 A 5 A 3 A 35 A 50 A 3 A Type Temperature Rated current class 851/01 T max. A T5 max. 10 A T max. 5 A 851/0 T max. 0 A T5 max. 35 A T max. 3 A Technical data I eff [A] 0595E / BA00 III en 0 Fuse base with fusible link Series 851 7
8 Transport and storage Selection Table Size thread Rated current Order number fuse element For further technical data, see Fuse link 05359E00 Adapter D01 A 851/ A A A A D0 0 A 851/ A D II E 7 A 851/ A A A A A A D III E A 851/ A A E E E00 Transport and storage Transport and store the device only in the original packaging. Store the device in a dry place (no condensation) and vibration-free. Do not drop the device. 7 Mounting and installation A prerequisite for safe functioning of the fuse element is its permanent mounting. 8 Fuse base with fusible link 195 / Series BA00 III en 0
9 Mounting and installation 7.1 Dimensions / fastening dimensions Dimensional Drawings (All Dimensions in mm / [inches]) - Subject to Alterations 0571E00 851/01 fuse element 851/0 fuse element 7. Mounting / dismounting, operating position The fuse element must only be installed, if it is fitted in an enclosure, that meets the requirements of an approved type of protection, according to IEC / , e.g. "Increased safety e". During installation of the component in an enclosure, that meets the requirements of the type of protection "Increased safety e", the clearance and creepage distances, according to IEC/ , must be adhered to. NOTICE Overheating A too short distance between individual components can cause overheating. Due to thermal reasons, a minimum distance of 9 mm has to be observed when several components are connected together. Fasten the device to the mounting holes, provided for this purpose, using suitable screws and accessories (see dimensional drawings). 057E00 When mounting the component, ensure presence of a flat surface. The operating position is optional. 195 / BA00 III en 0 Fuse base with fusible link Series 851 9
10 Maintenance and repair 7.3 Electrical Connection During installation, observe the following: The conductor must be connected carefully. The conductor insulation must reach to the clamping units. Do not damage the conductor (nicking) when stripping it. Ensure that the maximum permissible conductor temperatures and the maximum permissible surface temperature are not exceeded by selecting suitable electric lines and means of running them. 7. Commissioning Explosion hazard due to incorrect installation! Non-compliance results in severe or fatal injuries. Check the device for proper installation and function before commissioning. Comply with the national regulations. Before commissioning, make sure that: the components are not damaged, the device has been installed according to regulations, no foreign bodies are inside the device, all detachable connections have been tightened firmly, the prescribed tightening torques have been observed, the connection has been performed correctly. Mount / replace fuse link: - loosen safety screw. - unscrew fuse carrier. - if necessary, insert adapter. - if necessary, remove defective fuse link. - insert new fuse link into the fuse carrier. - screw the fuse carrier and the fuse link into the fuse base hand tight. - fasten the safety screw. 8 Maintenance and repair WARNING Risk of electric shock or malfunctioning of the device due to unauthorized work! Non-compliance can result in severe injuries and material damage. Work performed on the device must only be carried out by appropriately authorized and qualified electricians. 10 Fuse base with fusible link 195 / Series BA00 III en 0
11 8.1 Maintenance Maintenance and repair Danger due to energised parts! Risk of death or severe injuries! Before starting any maintenance work, disconnect the device from the power supply. Secure the device against unauthorized switching. WARNING Replacement of the fuse links must only be performed when the system is disconnected. Consult the relevant national regulations to determine the type and extent of inspections. Adapt inspection intervals to the operating conditions. During maintenance of the device, check at least: if the clamping screws holding the cables are securely seated, if the device enclosure and / or protective enclosure have cracks or other visible signs of damage, compliance with the permissible temperatures (according to 0079), if the nut is held securely in place A defect of the fuse link can be detected from the outside by means of the indicating pin. 8. Cleaning Clean the device only with a cloth, brush, vacuum cleaner or similar items. When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching cleaning agents. Do not use aggressive detergents or solvents. 8.3 Maintenance Observe the relevant national regulations in the country of use. 8. Repair If the components are damaged, they must be replaced. 195 / BA00 III en 0 Fuse base with fusible link Series
12 Disposal 8.5 Returning the device Use the "Service form" to return the device when repair/service is required. On the internet site " under "Downloads > Customer service": Download the service form and fill it out. Send the device along with the service form in the original packaging to R. STAHL Schaltgeräte GmbH. 9 Disposal Observe national and local regulations and statutory regulation regarding disposal. Separate materials when sending it for recycling. Ensure environmentally friendly disposal of all components according to the statutory regulations. 10 Accessories and Spare parts NOTE Malfunction or damage to the device due to the use of non-original components. Non-compliance can result in material damage. Use only original accessories and spare parts from R. STAHL Schaltgeräte GmbH. For accessories and spare parts, see data sheet on our homepage Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Adapter key 851/01 for replacement of adaptor Neozed Adapter key 851/0 0507E00 for replacement of adapter Diazed Terminal cover 0510E00 IP10 cover E00 1 Fuse base with fusible link 195 / Series BA00 III en 0
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationOperating Instructions
Operating Instructions Control unit Ex p > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationExplosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
More informationThe table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationFLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
More informationInstructions for Safe Use
Instructions for Safe Use (Certification N:o VTT 08 ATEX 029) Thank you for choosing Slam Trans portable transformer for your job site. Purpose of this manual is to provide you all the necessary safety
More informationInstallation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
More informationATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
More informationInfrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
More informationINSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed
More informationi410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
More informationModel 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
More informationTechnical data sheet TDS0070
Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier
More informationAntenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
More informationControl and Distribution Boxes made of Stainless Steel Series 8150
www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with
More informationalpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG Safety precautions Safety precautions The DSL modem alpha DSL WTM EG complies with the European norm EN60950 safety of information technology
More informationInstruction Manual Differential Pressure Transmitter
DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
More informationMounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationCompact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationAccessories SUNNY REMOTE CONTROL
Accessories SUNNY REMOTE CONTROL Mounting Instructions SRC20-MO-IEN121010 IMEN-SRC20 Version 1.0 EN SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This
More informationUser s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
More informationSOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
More informationaseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
More informationCAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 7-6 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
More informationMICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W
MICA HEATER INSTRUCTION MANUAL Model No: UHM-786 230V 50Hz 2200W Safety Precautions To reduce the risk of personal injury or damage to property, basic safety precautions must be observed including the
More informationDaily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
More informationTIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationOperating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard
More informationOperating Instructions Bedienungsanleitung Mode d emploi
Operating Instructions Bedienungsanleitung Mode d emploi DW 400 www.bron-kobold.com Operating instructions DW 400 Before use Please read all the information contained in these operating instructions carefully.
More informationOperating Instructions Drill rig DRU160
Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationHVAC Clamp Meter. Users Manual
902 HVAC Clamp Meter Users Manual PN 2547887 May 2006 Rev. 1, 3/07 2006-2007 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies. LIMITED
More informationEPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationInstructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationUSER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
More informationFloodlight Range Installation Guide
SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected
More informationAddendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
More informationHow To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
More information1. CONGRATULATIONS! You have bought a great new product from MAGICFX.
PRODUCT CODE : MFX0301 VERSION : 1.0 DATE : 11.12.2012 User documentation MAGICFX Power Shot 1. CONGRATULATIONS! You have bought a great new product from MAGICFX. MAGIC FX is a Dutch manufacturer of professional
More informationOriginal instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationDocumentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationElektromotoren und Gerätebau Barleben GmbH
Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety
More informationMIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
More informationUT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
More informationAchat 115MA full-range speaker. user manual
Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de
More informationIf you are familiar with these matters, then you can use this manual as a work of reference.
PRODUCT CODE : MFX0370 VERSION : 1.0 DATE : 16.12.2013 User documentation MAGICFX Confetti Gun 1. FOREWORD Congratulations! You have bought a great new product from MAGICFX. The MAGIC FX Confetti Gun is
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationAcclaim III Recessed Fluorescent Luminaires ATEX
Acclaim III Recessed Fluorescent Luminaires ATEX INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment.
More informationalpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationOperating Instructions Electronics module VEGADIF 65
Operating Instructions Electronics module VEGADIF 65 Document ID: 36132 Differential pressure Contents Contents 1 About this document 1.1 Function.................................. 3 1.2 Target group..............................
More informationElektromotoren und Gerätebau Barleben GmbH
Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1 Safety instructions
More information3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
More informationKNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119
EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationHAIR CLIPPER. Model No. HC5150 HC5150 2. 3.
All technical modifications reserved. 09/08. TSC 08.0634 HAIR CLIPPER 2. 3. 1. Model No. HC5150 4. 10/UK/HC5150 Version 03/10 Part No. T22-29458 REMINGTON is a Registered Trade Mark of Spectrum Brands,
More informationOperating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationBeoLab 7-1 BeoLab 7-2. Guide
BeoLab 7-1 BeoLab 7-2 Guide CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified service personnel. WARNING: To prevent
More informationReliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS
STORAGE and HANDLING The LED Illuminator meets or exceeds all applicable specifications when shipped from the factory. All units should be inspected upon receipt to ensure that no damage has been incurred
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationUSER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
More informationInstallation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V
Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................
More informationTina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationUser Manual. CFG253 3 MHz Function Generator 070-8362-04
User Manual CFG253 3 MHz Function Generator 070-8362-04 Copyright Tektronix, Inc. 1993. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
More informationConnection technology from ifm.
Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special
More informationCAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
BeoLab 4000 Guide CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No User-serviceable parts inside. Refer servicing to qualified
More informationINFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationKNX R. Rain Sensor. Installation and Adjustment
EN KNX R Rain Sensor Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical specifications... 3 2. Installation and commissioning... 4 2.1. Installation notes... 4 2.2. Location... 4
More informationLED Par 56 Short DMX ORDERCODE 42421
LED Par 56 Short DMX ORDERCODE 42421 Congratulations! You have bought a great, innovative product from Showtec. The Showtec LED Par 56 brings excitement to any venue. Whether you want simple plug-&-play
More information12. Inspection and Maintenance
12. and Maintenance Mandatory Be sure to inspect the inverter regularly and periodically to prevent it from breaking down because of the environment of use, such as temperature, humidity, dust and vibration,
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationRousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
More informationOPERATORS MANUAL MG22 MEAT GRINDER MG22/0209 ED 1 0011220
OPERATORS MANUAL MG22 MEAT GRINDER MG22/0209 ED 1 0011220 TO INSURE BOTH SAFE AND TROUBLE-FREE PERFORMANCE, WE STRESS THAT ALL PERSONNEL THAT WILL BE INVOLVED WITH YOUR NEW UNIVEX MEAT GRINDER MUST READ
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationPTB 07 ATEX 2048. Example/Beispiel/Exemple. Flipperventil 6144. Operating Instructions
PTB 07 ATEX 2048 Geräte mit IIC 2G EX ia Zulassung Device with IIC 2G EX ia approval Appareils avec mode de protection IIC 2G EX ia Example/Beispiel/Exemple Flipperventil 6144 Operating Instructions Bedienungsanleitung
More informationDehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
More information3/4 PIPE CLAMP WITH STAND
3/4 PIPE CLAMP WITH STAND Model 94053 ASSEMBLY AND OPERATING INSTRUCTIONS (3/4 DIAMETER PIPE NOT INCLUDED.) 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com
More informationOperating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 8-0 Fax +49 (0) 7938 8-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard
More informationNFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
More informationModel UT713 OPERATING MANUAL
Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC
More information