Technical Data. Programmer/Timer controls SM Channel Multi Purpose Programmer
|
|
- Damian Powers
- 7 years ago
- Views:
Transcription
1
2 The SMART family of programmers are a feature packed range, offering flexibility and reliability for use in any domestic heating and hot water installations. The blue back light on the programmer can be switched permanently on or off, depending on the user s preference. When the back light is off, it can be lit at the push of a button and will then turn off again. The programmer can be configured for 24 hour, 5/2 day or 7 day operation, and has the flexibility of up to three on/off timings per day. SM Channel Multi Purpose Programmer The SM1247 is a single channel multi purpose programmer, designed primarily for timed control of your heating and hot water. Ideal for use with a combination boiler or a single heating zone. It can also be used in conjunction with an existing programmer to control additional heating zones or for when additional hot water cylinder control is required. Programmer/Timer controls Large, easy to read LCD with blue back light 7 day, 5/2 or 24 hour operation 2 on/offs or 3 on/offs per day Automatic BST/GMT 1 hour time change Factory set clock and date Easy to use overrides Fits on industry standard backplate Electronics N L Mains COM OFF ON Fused 6A SM1247 Electronics N L HW CH HW CH Mains Fused 6A OFF OFF ON ON SM2247 2
3 SM Channel Multi Purpose Programmer The SM2247 is a two channel multi purpose programmer, designed for separate control of your heating and stored hot water. The heating and hot water programmes are independent of each other, giving you the opportunity to operate the system in the most energy efficient and cost effective manner. SM Channel Multi Purpose Programmer The SM3247 is our top of the range three channel multi purpose programmer, offering three completely independent time controlled channels. Ideal for control of two individual heating zones and separate hot water control giving you the opportunity to operate the system in the most energy efficient and cost effective manner. The multi-channel capabilities enables installers to comply with Part L of the amended Building Regulations by providing separate timed heating control for living and sleeping zones whilst also providing timed control of hot water. Electronics N L HW CH1 HW CH1 Mains Fused 6A OFF OFF ON ON SM CH2 CH2 OFF ON Power Supply 230V AC, 50Hz Operating Temperature 0 C to 35 C Total Switch Rating 230V AC, 6(2)A (Total) Contact Type 1B, Micro-Disconnection(Voltage Free) Battery Type Lithium Cell CR2032 Enclosure Protection: IP30 Plastics Thermoplastic, flame retardant Insulation Class Double Wiring For fixed wiring only Backplate Industry standard Clock BST/GMT time change Program Cycle Program On/offs per day Program Resolution Program Selection Program Override Heating System Complies with 140mm x 87mm x 37mm 12 hour am/pm, 1 minute resolution, accuracy +/- 2 sec/day Automatic 24hr, 5/2day or 7day selectable 2on/off, 3on/off selectable 10mins Auto, On all day, On constant, off +1,2 or 3Hr, Advance Pumped, Gravity selectable (SM1247/SM2247) EN , EN , EMC Directive 2004/108/EC, LVD Directive 2006/95/EC 3
4 The SMRTP is a 5/2 or 7 day programmable room thermostat designed to provide automatic time and temperature control of all domestic central heating applications. SMRTP Programmable Room Thermostat The SMRTP programmable room thermostat has a large, easy-to-read LCD display, includes many features, making it ideal for situations where a higher flexibility of control is required. This programmable room thermostat provides true 7 day (or 5/2 day) programming options, with up to six time and temperature events being available each day. The SMRTP comes pre-programmed for ease of use, but the user can create their own individual programme or modify the existing option. With built in summer/winter changeover, this product eliminates the need for time-setting and BST/GMT time changes. Time and date are factory-set, making time setting or adjustment unnecessary. Programmable Room Thermostat Large, easy to read LCD with blue back light 7 day or 5/2 programming options Up to 6 time and temperature events Easy to use overrides Automatic BST/GMT 1 hour time change Factory set clock and date Pre-set built in programme Programmable Room Thermostat SMRTP Programming 7 & 5/2 day Power Supply 2 X Alkaline Batteries 1.5V (Type AA) Temperature Adjustment Range 7 C to 34 C Total Switch Rating 8(2)A 230 Vac Contact type 10A, 250 Vac (volt free changeover contacts) Power Reserve 3 years Plastics Thermoplastic, flame retardant Protection Rating IP30 110mm x 83mm x 26mm Number of events per day Up to 6 BST/GMT time change Automatic Factory Pre-set programme Yes Complies with EN , EN , EMC Directive 2004/108/EC, LVD Directive 2006/95/EC 4
5 The SMRTPRF is a 5/2 or 7 day wireless programmable room thermostat designed to provide automatic time and temperature control of all domestic central heating applications. SMRTPRF Wireless Programmable Room Thermostat The SMRTPRF wireless programmable thermostat has a large, easy-to-read LCD display, includes many features, making it ideal for situations where a higher flexibility of control is required. This programmable room thermostat is battery powered and provides true 7 day (or 5/2 day) programming options, with up to six time and temperature events being available each day. The SMRTP/SMRTPRF come pre-programmed for ease of use, but the user can create their own individual programme or modify the existing option. With built in summer/winter changeover, this product eliminates the need for time-setting and BST/GMT time changes. Time and date are factory-set, making time setting or adjustment unnecessary. Wireless Programmable Room Thermostats Large, easy to read LCD with blue back light 7 day or 5/2 programming options Up to 6 time and temperature events Easy to use overrides Automatic BST/GMT 1 hour time change Factory set clock and date Pre-set built in programme Wireless Programmable Room Thermostat SMRTPRF Programming 7 & 5/2 day Power Supply 2 X Alkaline Batteries 1.5V (Type AA) Temperature Adjustment Range 7 C to 34 C Total Switch Rating 8(2)A 230 Vac Contact Type Wireless Power Reserve 3 years Plastics Thermoplastic, flame retardant Protection Rating IP30 110mm x 83mm x 26mm Number of events per day Up to 6 BST/GMT time change Automatic Factory Pre-set programme Yes Complies with EN , EN , EMC Directive 5
6 The stylish range of Electronic Room Thermostats from SMART are designed to outperform many older thermostats and should be able to produce savings in the order of 10% over and above those achieved by traditional units using older technology. The temperature control accuracy of +/- 0.6ºC will reduce the temperature swing that normally occurs with older style thermostats. SMRTED Electronic Room Thermostat, with LCD Display The SMRTED room thermostat is economical and simple to use. Simply turn the control dial to the desired temperature to control the room temperature. The SMRTED includes a battery powered LCD display which displays the current room temperature. When the temperature is adjusted, the LCD display will briefly display the revised temperature before returning to the current room temperature. SMRTE2 Electronic Room Thermostat The SMRTE2 Electronic Room Thermostat is an economical and simple to use room thermostat. Simply turn the control dial to the desired temperature to control the room temperature. This unit also includes a neon indicator that lights up when the system is calling for heat, so you know when the system is being turned ON or OFF. The SMRTE2 requires a live and neutral power supply of the appropriate voltage. Electronic Room Thermostats Large, clear adjustable dial TPI Technology (SMRTED) Neon indicator when system is turned ON/OFF LCD display (SMRTED) Double insulated Surface mounted Temperature control accuracy of +/- 0.6ºC Standard industry black plate Electronic Room Thermostat, with LCD Display SMRTED Fixing Standard Industry Back plate Sensing Element Electronic Switch Rating 8(2)A 230V Ac, Temperature setting Range 5 C to 35 C Current Rating 16(4) Amp Terminal Differential <0.6 C at 4 /hour Switch type S.P.S.T. L83 x H83 x D35 Complies with: EN , En , EMC Directive 2004/108/EC, LVD Directive 2006/95/EC Electronic Room Thermostat SMRTE2 Fixing Standard Industry Back plate Sensing Element Electronic Switch Rating 8(2)A 230V Ac, Temperature setting Range 5ºC to 35ºC Current Rating 16(4) Amp Terminal Differential <0.6 C at 4 /hour Switch Type S.P.S.T. L83x H83x D35 Complies with: EN , En , EMC Directive 2004/108/EC, LVD Directive 2006/95/EC 6
7 The modern and stylish Wireless Electronic Room Thermostat from SMART is designed to outperform many older thermostats and should be able to produce savings in the order of 10% over and above those achieved by traditional units using older technology. The temperature control accuracy of +/- 0.6ºC will reduce the temperature swing that normally occurs with older style thermostats. SMRTERFW Wireless Electronic Room Thermostat, with LCD Display The SMRTERFW room thermostat is economical and simple to use. Simply turn the control dial to the desired temperature to control the room temperature. The SMRTERFW includes an LCD display which displays the current room temperature. When the temperature is adjusted, the LCD display will briefly display the revised temperature before returning to the current room temperature. Wireless Electronic Room Thermostat Large, clear adjustable dial TPI Technology Neon indicator when system is turned ON/OFF LCD display Surface mounted Temperature control accuracy of +/- 0.6ºC Standard industry back plate Wireless Electronic Room Thermostat, with LCD Display SMRTERFW Fixing Standard Industry Back plate Power Supply 2 x AA/MN1500 alkaline batteries Sensing Element Electronic Switch Rating 8(2)A 230V Ac, Temperature setting Range 5 C to 35 C Current Rating 16(4) Amp Terminal Differential <0.6 C at 4 /hour Switch type S.P.S.T. L83 x H83 x D35 Complies with: EN , En , EMC Directive 2004/108/EC, LVD Directive 2006/95/EC 7
8 SMRTM Mechanical Room Thermostat SMCTS Clamp-on Cylinder Thermostat System The SMRTM mechanical room thermostat is an economical and simple to use room thermostat. Simply turn the mechanical control dial to your desired temperature to control your room temperature. This unit also produces an audible click when you turn the dial past the current temperature so you know when the system is being turned ON or OFF. The mechanical two wire thermostat is very easy to install and, by having volt free contacts, is suitable for systems with either a combination or normal boiler. If you have a three wire installation, simply cut back and make safe the neutral, and this two wire thermostat will give you years of faithful service. System The SMCTS Cylinder Thermostat is configured specifically for the control of domestic hot water cylinders to suit householder lifestyles and can provide energy savings when set between the recommended 60 C - 65 C. Supplied complete with a mounting strap for the cylinder and a spring for the heating pipes, this unit is very easy to fit around either the cylinder or pipe. The bimetallic sensor ensures accurate hot water temperature control, while the large clear adjustable dial is easy to read and adjustable between 0 C and 80 C. The Cylinder Thermostat can be used to switch directly a wet central heating circulating pump or boiler, or to operate zone valves. Mechanical Room Thermostat Cylinder Thermostat Volt free contacts Audible click when dial is turned past current temperature and system is turned on/off Surface mounted Large, clear adjustable dial Fits on industry standard back plate Mechanical Room Thermostat SMRTM Power Supply 230V Ac, 50-60Hz Temperature setting Range 10 C to 30 C Current Rating 16(4) Amp Terminal Differential Approx 4 C Operating Temperature Range 0 C to 40 C L83x H83x D37 EN , En , Complies with: EMC Directive 2004/108/EC, LVD Directive 2006/95/EC Double insulated Bimetallic sensor ensures accurate hot water temperature control Wide temperature range Surface mounted Large, clear adjustable dial Cylinder strap and hooks Clamp-on Cylinder Thermostat SMCTS Operation Range Min 0 C - Max 80 C Tolerance Min ± 6 C - Max ± 4 C Differential ± 8 C Switch Action SP PT Type 1CL Contact Rating 16(4) A 230V Protection IP40 Max Surface Temperature 110 C Fixing Plastic coated spring wire (1800m) with hooks 8
9 System SMTRV Thermostatic Radiator Valve The SMTRV is a stylish and easy to use Thermostatic Radiator Valve (TRV) that has been designed to provide years of trouble free service. The liquid filled head is easy to fit and has the option to manually set and lock a maximum temperature, to provide even more heating control. System SMABV22 Auto Bypass Valve The SMABV22 is designed to maintain the water flow in central heating systems fitted with TRVs. They do this by maintaining the desired minimum flow rate through the boiler and limit circulation pressure when water paths may be closed. The SMABV22 reduces system noise that may be caused from TRVs or zone valves closing, eliminates pump impeller wear that can result from high flow resistance, enhances the life of the boiler heat exchanger by ensuring minimum flow rate at all times, and saves energy by only allowing flow through the bypass when needed. The use of an ABV is recommended by the UK Government as Best Practice in the CHeSS guide to central heating systems. Building Regulation advice states that if a bypass is installed, an ABV must be fitted. Thermostatic Radiator Valve Auto Bypass Valve Bi-directional flow design Can be mounted vertically or horizontally Optional locking facility for public areas Liquid filled sensor for consistent and reliable results Simple to use and easy to install Thermostatic Radiator valve Maximum Working Pressure Maximum Differential Pressure Pipework Connection Sensing Element Thermostatic Radiator valve Pack Includes SMTRV 10.0 bar 1.0 bar 15mm Liquid SMTRVP 1 x 15mm TRV valve & head 1 x 15mm Lockshield 2 x 15mm Tailpiece 2 x 1 /2 Olive 22mm compression fitting Reduces system noise 16 bar maximum pressure 120 C intermittent temperature High capacity flow, up to 50 litres per minute Wide differential pressure range, 0.05 to 0.5 Automatic Bypass Valve SMABV22 Connections 22mm Compression Joints Differential Pressure Range 0.05 to 0.5 Max Working Pressure 16 Bar Working Temperature 120 C Intermittent Ensures a constant flow through the boiler 9
10 System SMAVB Automatic Air Vent, 3/8" and 1/2" The SMAVB Automatic Air Vent is designed for heating systems and other closed circuit hot water systems which require the efficient, automatic removal of air when a system is filling with water. The SMAVB allows quick and easy removal of trapped air from sealed heating systems without draining down the system and reduces, and often eliminates, the need for bleeding. The SMAVB features a vacuum break on the base of the valve to prevent an air lock forming and to encourage air to be released from water. The SMAVB can be fitted anywhere in the positive pressure side of the system where air is likely to be trapped, although it should be installed in an accessible and visible area to ensure it can be serviced easily. System SMAVB15 Automatic Air Vent, Cylinder Style with 15mm Compression Fittings The SMAVB15 Automatic Air Vent is designed for heating systems and other closed circuit hot water systems which require the efficient, automatic removal of air when a system is filling with water. The SMAVB15 allows quick and easy removal of trapped air from sealed heating systems without draining down the system and reduces, and often eliminates, the need for bleeding. The SMAVB15 is a cylinder-style Automatic Air Vent with 15mm compression fittings. It can be fitted anywhere in the positive pressure side of the system where air is likely to be trapped, although it should be installed in an accessible and visible area to ensure it can be serviced easily. Automatic Air Vent Automatic Air Vent 3/8" and 1/2" BSP connections Vacuum break to prevent air locks Ensures efficient and automatic removal of air Simple to service and / or clean Saves time and money when installing a new heating system Reduces and often eliminates the need for bleeding Prevents corrosion and problems with operation Automatic Air Vent Connections Operating Temperature Max Working Pressure Valve Body Material SMAVB 3/8 and 1/2 inch 110ºC Maximum 6 Bar Brass 15mm compression fittings Brass body Ensures efficient and automatic removal of air Saves time and money when installing a new heating system Prevents corrosion and problems with operation Automatic Air Vent Connections Operating Temperature Max Working Pressure Valve Body Material SMAVB15 15mm Compression fitting 110ºC Maximum 6 Bar Brass 10
11 System SMZV222/SMZV282/SMZV223 2/3 Port Zone Valves The SMART range of Motorised Zone Valves are easy-fit, with a simple clip on/off detachable actuator head and plug & play cable. The actuator has been designed to fit directly onto the valve body used by the market leader, and similar type bodies, with the two supplied screws - making it a quick-fit direct replacement for most households. The spring return valves have been designed to be used in commercial, industrial and domestic central heating systems which, when correctly wired with an appropriate room thermostat, cylinder thermostat and programmer, will control the water flow from the boiler to hot water, and from the boiler to central heating. SMZVA222/SMZVA223 2/3 Port Actuator Heads System SMWC1 Wiring Centre The SMWC1 Wiring Centre is designed to be a safe and convenient method of system wiring. The SMWC1 provides a safe means of connection whilst reducing installer time by simplifying the wiring and circuit testing, with a dedicated terminal block for each system component. The SMWC1 is suited to all popular heating systems and manufactured in a robust fire retardant ABS. 2 & 3 Port Zone Valves Wiring Centre A direct replacement for the market leader Spring return action Manual lever for filling / draining the system Replacement actuator head and motor available and easy to exchange Detachable lead Quiet operation, minimum power usage Quick and easy to install 2 Port Zone Valve, 22mm & 28mm SMZV222 & SMZV282 3 Port Zone Valve, 22mm SMZV223 Actuator Head SMZVA222 (2 Port) SMZVA223 (3 Port) Supply Voltage VAC, 50/60Hz Power Consumption 5W Cable Length 1m - Plug in Cable Fluid Temperature Min-Max +5 C -+88 C Operating Temperature 5 C to +50 C Flow Direction As per arrow on valve body Auxiliary Switch Rating 250VAC 4A (2 Port) / 250VAC 3A (3 Port) Response Opening 12 seconds Response Closing 5 seconds Max Static Pressure 8 Bar Max Close-off Pressure 1 Bar (2 Port) / 0.69 Bar (3 Port) Complies with EN , EN , EMC Directive 2004/108/EC, LVD Directive 2006/95/EC Simplifies wiring and circuit testing Suited to all popular heating systems Reduces installer time Robust fire retardant ABS Dedicated terminal block for each system component Wiring Centre SMWC1 Protection Rating IP20 Maximum Ambient Temperature 55ºC Maximum Current - PCB 5A 230V 50Hz Fuse Rating 2A 230V 50Hz 11
12 12 Smart Controls Votec House Hambridge Lane Newbury Berkshire RG14 5TN
Installation & User Instructions
103 electro-mechanical 24 hour timeswitch for controlling hot water and heating Installation & User Instructions including Factory Replacement Units (FRU) Certification Mark This product complies with
More informationProgrammable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationWireless 7 Day Programmable Room Thermostat
Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable
More informationCM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationSET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark
SET1E Electronic timeswitch for heating & hot water Installation & User Instructions Certification Mark Index INDEX Installation Product specification 3 Installation 4-5 Wiring 5-10 Replacement 11-13 User
More informationevohome Wireless Radiator Zoning Kit Installation & User Guide
evohome Wireless Radiator Zoning Kit Installation & User Guide Getting the most from your evohome system Installation & User Guide 1 Getting the most from your evohome system Thanks for choosing an evohome
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationElectric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
More informationFully Pumped Systems
Fully Pumped Systems (also see the picture gallery and System Basics) The term for any boiler that uses a pump to move all the heat from the boiler to every part of the system is fully pumped. As a rule
More informationSET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions
SET3M electro-mechanical 24 programmer for heating & hot water Installation & User Instructions Index Installation Product specification 3 Installation 4-5 Wiring 6-12 Replacement 13-15 User Your programmer
More informationMaxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
More informationFrequently Asked Questions
What is a Thermostatic Radiator Valve? TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler.they should
More informationELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationInstallation Guide for Hive Active Heating
Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during
More informationTable of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature
LHZ USER GUIDE LHZ User Guide LHZ would like to thank you for purchasing your LHZ radiator. You have purchased a high quality, German designed and manufactured heating device, which will give you soft
More informationits ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
More informationXE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to
More informationGuidance on how to comply with the 2010 Building Regulations Part L
Guidance on how to comply with the 2010 Building Regulations Part L Version 2.0 10 December 2010 This guide supports the official guidance covering the use of controls in boiler based, gas and oil fired
More informationCR9971 2 Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use
ROBERTS Sound for Generations CR9971 2 Band Auto Set Dual Alarm Clock Radio Please read this manual before use Contents Contents... 1 Controls...2-5 Switching on... 6 Setting the time manually... 6 Setting
More informationTICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System
TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install
More informationDrayton Digistat +2RF
Drayton Digistat +2RF T Programmable Room Thermostat Wireless 24 Hour Model: RF700/22090 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130
More informationGuidance on how to comply with the 2013 Building Regulations Part L
Guidance on how to comply with the 2013 Building Regulations Part L Version 1.0 6 April 2014 This guide supports the official guidance covering the control of gas and oil fired wet central heating installations
More informationHEATING CONTROLS MAY 2014
HEATING MAY 2014 YOUR HEATING PARTNER About Us EPH Controls Ltd. is a specialist heating controls company serving both the residential and commercial markets. Formed 17 years ago, EPH began trading as
More informationINSTALLATION & TECHNICAL MANUAL
The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk
More informationAlpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
More informationDC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
More informationInstallers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.
DOMESTIC HEATING CONTROLS ARE EASY PART 5 - RADIATOR THERMOSTATS Fig.1. RAS-C 2 and RAS-D 2 radiator thermostats with RLV-D lockshield valve Radiator Thermostats (TRVs), the original and straight forward
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationTMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationRVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
More informationOperating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2
Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2 Heatmiser UK td Tel: +44(0)1254 776343 Primrose House www.heatmiser.co.uk Primrose Street Darwen ancashire BB3 2DE Contents Contents 1 Installation
More informationOperators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
More informationFAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationData sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G
Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN
More informationData sheet ECC 12 and 22
Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe
More informationPlease also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
More informationHeating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
More informationSmile. The All-In-One Heating Controller
Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationUSERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
More informationRF 1. Contents: Connecting diagram. Detailed information:
Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)
More informationHand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationSensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.
Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual
More informationSELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
More informationCOMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationT5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
More informationHCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationFIREDEX 2200. Conventional Fire Panels
68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class
More informationManual & Technical Documentation V1.1
Manual & Technical Documentation V1.1 tado Smart Thermostat tado Extension Kit ENGLISH Content Product Packages Compatibility Intelligence & Security Functions Smart Thermostat Usage Menu Structure Special
More informationOperating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
More informationUSERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
More informationWater Metering System SmartMeter Prepayment. SmartMeter Prepayment. Water Metering System
Water Metering System SmartMeter Prepayment SmartMeter Prepayment Water Metering System Water Metering System SmartMeter Prepayment SmartMeter Prepayment Water Metering System A dynamic approach to Prepayment
More informationMAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL
More information225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
More informationThis unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More informationCM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?
WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?...an explanation for householders A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set On and Off time periods
More informationecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationwww.the Floor Heating Warehouse.co.uk
www.the Floor Heating Warehouse.co.uk Underfloor Heating Installation Guide (Grundfoss Pump System) General Overview: Our water based underfloor heating system can be installed by your own plumber or heating
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More information1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationHigh Output Boiler Systems
High Output Boiler Systems Information for Dual System Link up methods For use in GB & IE (Great Britain and Republic of Ireland). This appliance has been certified for use in countries other than those
More informationFor installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
More informationwww.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A
SmartChargePro7 RSCPR7-12v, 7A SmartChargePro10 RSCPR10-12v, 10A SmartChargePro15 RSCPR15-12v, 15A SmartChargePro25 RSCPR25-12v, 2 / 6 / 12 / 25A SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro50
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationFrequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55
Frequently Asked Questions Air Top Diesel Heaters 2000STC, Evo 40 & Evo 55 Question 1 What power outputs are the heaters available in? There are 3 models 2kW, 4kW and 5.5kW Question 2 What voltage are
More informationINNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
More informationUNDERFLOOR HEATING SYSTEMS DETAILS AND NOTES
UNDERFLOOR HEATING SYSTEMS DETAILS AND TES CONTENTS 1 MANIFOLD DETAILS AND DIMENSIONS 2 TYPICAL CIRCUIT LAYOUT DETAILS 3 JOISTED SYSTEM DETAIL ( PLATES FROM ABOVE ) 4 JOISTED SYSTEM DETAIL ( PLATES FROM
More informationZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8
ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8 Quick Start A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device.
More informationCM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES CM927 can be installed without disrupting your room décor as no wiring connection is required between the room unit and the boiler Attractive, slim, ultra-modern
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
More informationCO2 Alarm. Operation. Application
CO Alarm 100-77V AC Supply Voltage Two pre-configured alarm and control thresholds Thresholds factory set to customer requirements on dispersive infrared sensing technology Optional internal audible alarm
More informationSmart Thermostat page 1
Smart Thermostat page 1 3. APPROACH In today s home appliances market, automation is becoming the norm and Smart Thermostat is a typical automation appliance able to be applied easily at home. With Smart
More informationWireless Thermostats 230v and Battery Operated Instruction Manual
Wireless Thermostats 230v and Battery Operated Instruction Manual For models: JGSTATW2W JGSTATW2B JGSTATW1W JGSTATW1B Contents Box contents: Wireless Thermostats 230v and Battery Operated Instruction Manual
More informationLK Electric Boiler - 4,5
LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered
More informationMFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationOwner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable
Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10 Programmable thermostat Thermostat programmable Termostato programable Read and save these instructions. Veuillez lire le mode d
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationTS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
More informationElectric Flow Boiler
Electric Flow Boiler Installation & technical Manual If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: info@electric-heatingcompany.co.uk or visit our website www.electric-heatingcompany.co.uk
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationUSB-500 Series Stand-Alone, Low-Cost Data Loggers
Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use
More informationFlow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
More information