Table of Contents Safety Information.. 1 Your Digital Multimeter Making Measurements... 12

Size: px
Start display at page:

Download "Table of Contents Safety Information.. 1 Your Digital Multimeter Making Measurements... 12"

Transcription

1 Users Manual

2

3 Table of Contents Safety Information.. 1 Important Safety Instructions. 1 Symbol Explanation. 4 Your Digital Multimeter Introduction... 5 Names of Components... 8 LCD Display Other Functions Making Measurements Introduction Measuring DC/AC Volts Measuring DC/AC Milliamps. 15 Measuring DC/AC Amps Measuring Resistance and Continuity 19

4 Measuring Capacitance Measuring Inductance Measuring Frequency Measuring Temperature Diode Testing TTL Logic Testing Transistor Testing User Maintenance Replacing the batteries. 33 Replacing the Fuses 34 Others 35 Specifications General Specifications.. 36 Resolution and Accuracy 37

5 Safety Information READ THIS MANUAL CAREFULLY BEFORE USING THIS MULTIMETER! The digital multimeter has been designed according to IEC concerning safety requirements for electrical measuring instruments with an overvoltage category (1000V CAT ) and pollution 2. Important Safety Instructions Injury or death can occur even with low voltages and low current. It is extremely important that you read this safety information before using your multimeter. Follow all safety practices and proper operating procedures for equipment being tested. 1

6 Disconnect the power and discharge high-voltage capacitors before testing in Ohms, Continuity, Diode, Capacitance, and other test of on circuit Inspect the test leads for damaged insulation or exposed metal. Check test lead continuity. Damaged leads should be replaced. Do not use the instrument if it looks damaged. Select the proper function and range for your measurement. User caution when working above 60V DC or 30V AC rms. Such voltages pose a shock hazard. Disconnect the live test lead before disconnecting the common test lead. When using the probes, keep your fingers away from probe contacts. Keep your fingers behind the finger guards on the probes. When measuring current, turn the power off to the circuit being tested before connecting the meter test lead in the circuit. 2

7 Place test leads in proper input terminals Measurement time must fewer 10 seconds at measuring great current every times, and the interval time must more 15 minutes every times. Do not operate this multimeter in an explosive atmosphere (i.e., in the presence of flammable gases or fumes, vapor or dust.). Never replace the protective fuse inside the multimeter with a fuse other than the specified or approved equal fuse. Replace only with same type of fuses. To avoid electrical shock, disconnect the test leads and any input signals before replacing the fuses. Replace only with same type of battery. To avoid electrical shock, disconnect the test leads and input signals before replacing the battery. Do not attempt calibration or service unless trained and another person capable of rendering first aid and resuscitation is present. 3

8 Symbol Explanation Attention! Refer to the user manual Dangerous voltage may be present at terminals Ground (Earth terminal) AC(Alternating current) DC(Direct current) AC or DC Battery Fuse Conforms to European Union directives Double insulation (Protection Class Ⅱ) 4

9 Your Digital Multimeter Introduction This meter is a portable professional measuring meter with digital and 40 segment graph bar display. And the meter has functions of date hold and back light, to easily read measurement result. Overload protection and low battery indication are provided, this meter is ideal for use in the fields, workshop, school, hobby, and home applications. Include following measuring functions: DC/AC Volts DC/AC Current Resistance Capacitance Inductance Frequency Temperature Continuity Diode Transistor TTL logic 5

10 AC hfe khz H mh M k ma A uf nf mv V LIGHT / HOLD Lx/Cx 200m Lx u 2u 200n 20n 2n Cx 10A ON OFF 2m 20m hfe PNP NPN 200 2k 20k kHz 200m 20m 2m A ma Lx COM 200k 2M 20M 200m 2 20 V V CAT II V Hz 1000V 700V Figure 1 6

11 D ELECTRICA E TEST LEADS G BATTERY C EETS:IEC1010 CAT III POLLU VENT FIRE, US 10A/250V 6 0.5A/250V 5.5V X 6 SIZE A Figure 2 7

12 Names of Components. LCD Display measuring result and function, and other symbol. ⑵. key When measuring AC, you must press down this key at Volts or Current range. ⑶. LIGHT Key When press down the key, Backlight will be on; backlight will be self-off about six seconds later. ⑷. Power Switch When press down this key, the meter s power will be on. ⑸. Function/Range selector rotary switch This switch selects the function and range. ⑹. Cx socket This Cx socket is made testing capacitor. ⑺.10A input terminal (socket) This is the positive input terminal for current measurement (AC or DC) up to 10A. 8

13 . /ma/lx input terminal (socket) This is the positive input terminal for temperature, ma or inductance. ⑼.COM input terminal (socket) This is the negative (ground) input terminal for all measurement modes. ⑽.V/Ω/Hz input terminal (socket) This is the positive input terminal for volts, resistance, frequency, diode continuity and logic. ⑾.Transistor socket This socket is made testing transistor. ⑿.HOLD key To press down this key, the display value will be locked and keep unchanged. To press the key again, the locked status will be erased and enter normal measurement status. ⒀.Lx/Cx key This key must be pressed down when measuring capacitance and inductance. ⒁.Bottom case 9

14 .Meter s bracket ⒃.Battery cover ⒄.Special screws The screws are used to fix battery. LCD Display AC hfe khz H mh M k ma A uf nf mv V Figure 3 ⑴. The HOLD function is on. ⑵. AC measurement status. ⑶. Negative measurement value. ⑷. hfe Transistor measurement status. 10

15 . Indication low battery ⑹. Analog graph bar ⑺. TTL logic test, When display, indication high logic; when display, indication low logic. ⑻. Display unit of measurement. ⑼. Continuity measurement status. ⑽. Display unit of measurement. ⑾. Diode measurement status. ⑿. Indication dangerous voltage (high volts). Other Functions ⑴. Auto power off. The meter will auto power off after about 10 minutes. Press up the key and press down the key, the power will be on again. ⑵. Buzzer. When doing continuity test, if the resistance is smaller than 50Ω, the buzzer will be sound. And when doing TTL logic test, if measurement result is low logic, the buzzer will be sound. 11

16 . Backlight. If the light is dark to make the reading difficult when measuring, you can press LIGHT key to open the back light. ⑷. Date Hold. If you need data hold when measuring, you can put on HOLD button, it will hold the reading; if you put the button again, data hold is not continue. Making Measurements Introduction This chapter shows overall procedures for making measurements in any of the rotary selector positions. Necessary input connections are shown. And safety information is showed. 12

17 Measuring DC/AC Volts ON OFF 200m Lx u 2u 200n 20n 2n Cx 10A 2m 20m hfe PNP NPN 200 2k 20k kHz 200m 20m 2m A ma Lx COM 200k 2M 20M 200m 2 20 V V CAT II V Hz V 1000V 700V Figure 4. Connect the black test lead to the COM jack and the red test lead to the V jack. ⑵. Set the range switch at the desired V range position. Connect the test leads as shown Figure 4. ⑶. When only the figure OL is displayed, it 13

18 indicates over range situation and the higher range has to be selected.. You can get a reading from LCD display. The polarity of the red lead connection will be indicated along with the voltage value. ⑸. When measuring AC volts, please press down the key; when measuring DC volts, please press up the key. WARNING: Can t measure higher than 1000V DC or 700V AC RMS. When the magnitude of the voltage to be measured is unknown, always set the rotary selector at the highest range. Don t touch any electrical conductors, to avoid electrical shock. After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 14

19 Measuring DC/AC Milliamps ON OFF 200m Lx u 2u 200n Cx 10A hfe 2m 20m 20n 2n m 20m 2m A ma Lx 200 2k 20k 2M 20M 200m 2 20 V kHz 1000V CAT II COM PNP NPN 200k V Hz ma 1000V 700V Figure 5. Connect the black test lead to the COM jack and the red test lead to the ma jack. ⑵. Set the range switch at the desired ma range position. Connect the test leads as shown Figure 5. ⑶. When only the figure OL is displayed, it indicates over range situation and the higher 15

20 range has to be selected.. You can get a reading from LCD display. The polarity of the red lead connection will be indicated along with the voltage value. ⑸. When measuring AC current, please press down the current, please press up the key; when measuring DC key. WARNING: Can t measure higher than 200mA in ma range, otherwise the fuse will blowout. After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 16

21 Measuring DC/AC Amps ON OFF 200m Lx u hfe 2m 20m PNP NPN 200 2k 20k 200k 2M 20M 200m A 2u 200n Cx 10A 20n 2n m 20m 2m A ma Lx kHz COM V CAT II V Hz V 1000V 700V Figure 6. Connect the black test lead to the COM jack and the red test lead to the 10A jack. ⑵. Set the range switch at the desired 10A range position. Connect the test leads as shown Figure 6. ⑶. When only the figure OL is displayed, it 17

22 indicates over range situation.. You can get a reading from LCD display. The polarity of the red lead connection will be indicated along with the voltage value. ⑸. When measuring AC current, please press down the current, please press up the key; when measuring DC key. WARNING: Can t measure higher than 10A, otherwise the fuse will blowout. Measurement time must fewer 10 seconds at measuring great current every times, and the interval time must more 15 minutes every times. After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 18

23 Measuring Resistance and Continuity 200m Lx u 200n Cx 2u 10A 20n 2n ON OFF hfe 2m 20m m 20m 2m A ma Lx 200 2k kHz COM 20k 200 PNP NPN 200k 20 2M 20M 200m V 1000V CAT II V Hz 1000V 700V Figure 7. Connect the black test lead to the COM jack and the red test lead to the Ω jack. ⑵. Set the range switch at the desired resistance range position. Connect the test leads as shown Figure 7. ⑶. When only the figure OL is displayed, it 19

24 indicates over range situation and the higher range has to be selected.. You can get a reading from LCD display. ⑸. When doing continuity test, if the resistance is smaller than 50Ω, the buzzer will be sound. Connect the test leads as shown Figure 7. WARNING: Before measuring resistance in circuit to be sure power off; and to be sure capacitance has been discharge fully. After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 20

25 Measuring Capacitance 200m Lx u 2u 200n 20n 2n Cx 10A ON OFF 2m 20m hfe PNP NPN 200 2k 20k kHz 200m 20m 2m A ma Lx COM 200k 2M 20M 200m V V CAT II V Hz 1000V 700V Figure 8. Set the range switch at the desired Cx range position and select proper range. and press down Lx/Cx key. ⑵. Insert the capacitance to the test socket as shown Figure 8. 21

26 . When only the figure OL is displayed, it indicates over range situation and the higher range has to be selected. ⑷. You can get a reading from LCD display. WARNING: Before measuring capacitance in circuit to be sure power off; and to be sure that has been discharge fully. After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 22

27 Measuring Inductance 200m Lx u 2u 200n 20n 2n Cx 10A ON OFF 2m 20m hfe PNP NPN 200 2k 20k kHz 200m 20m 2m A ma Lx COM 200k 2M 20M 200m 2 20 V V CAT II V Hz 1000V 700V Figure 9. Connect the black test lead to the COM jack and the red test lead to the Lx jack. ⑵. Set the range switch at the desired Lx range position. Connect the test leads as shown Figure9. 23

28 . When only the figure OL is displayed, it indicates over range situation and the higher range has to be selected. ⑷. You can get a reading from LCD display. WARNING: Before measuring inductance in circuit to be sure power off; and to be sure capacitance has been discharge fully. After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 24

29 Measuring Frequency ON OFF 200m Lx u 2u 200n 20n 2n Cx 10A 2m 20m hfe PNP NPN 200 2k 20k kHz 200m 20m 2m A ma Lx COM 200k 2M 20M 200m 2 20 V V CAT II V Hz V 1000V 700V Figure 10. Connect the black test lead to the COM jack and the red test lead to the Hz jack. ⑵. Set the range switch at the desired 20 khz range position. Connect the test leads as shown Figure10. 25

30 . When only the figure OL is displayed, it indicates over range situation. ⑷. You can get a reading from LCD display. WARNING: Determine that the amplitude level of the signal to be measured is not greater than the input voltage limit (250V). After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 26

31 Measuring Temperature 200m Lx u 2u 200n 20n 2n Cx 10A ON OFF 2m 20m hfe PNP NPN 200 2k 20k kHz 200m 20m 2m A ma Lx COM 200k 2M 20M 200m 2 20 V V CAT II V Hz 1000V 700V Figure 11. Insert the Thermocouple to the COM jack and jack. ⑵. Set the range switch at the desired range position. Connect the test leads as shown Figure11. 27

32 . Put the Thermocouple on the object to be measured. ⑷. When only the figure OL is displayed, it indicates over range situation. ⑸. You can get a reading from LCD display. WARNING: The meter will display temperature inside meter, if no thermocouple. Don t enter and measure other signal. After measuring completely, disconnection the thermocouple and object to be measured, and remove the thermocouple from the meter. 28

33 Diode testing 200m Lx u 2u 200n 20n 2n Cx 10A ON OFF 2m 20m hfe PNP NPN 200 2k 20k kHz 200m 20m 2m A ma Lx COM 200k 2M 20M 200m 2 20 V V CAT II V Hz 1000V 700V Figure 12. Connect the black test lead to the COM jack and the red test lead to the jack. ⑵. Set the range switch at the desired range position. Connect the test leads as shown Figure12. 29

34 . The typical voltage drop should be about 0.6V for silicon diode or 0.3V for germanium diode ⑷. If the diode is reversing biased or there is an open circuit, The OL is displayed on LCD. ⑸. You can get a reading from LCD display. WARNING: Before measuring in circuit to be sure power off; and to be sure capacitance has been discharge fully. After measuring completely, disconnection the test leads with the circuit to be measured, and remove the test leads from the meter. 30

35 TTL Logic Testing ON OFF hfe 2m 20m 200m Lx u PNP NPN 200 2k 20k 200k 2M 20M 200m 2u 200n Cx 10A 20n 2n m 20m 2m A ma Lx kHz COM V CAT II V Hz V 1000V 700V Figure 13. Connect the black test lead to the COM jack and the red test lead to the V jack. ⑵. Set the range switch at the desired range position. Connect the test leads as shown Figure13. ⑶. When only the figure OL is displayed, it indicates over range situation and the higher 31

36 range has to be selected.. When volts (logic level) 0.8V, the will be displayed on LCD and buzzer will be sound. When volts (logic level) 2.0V, the displayed. will be Transistor Testing ON OFF hfe 2m 20m 200m Lx u PNP NPN 200 2k 20k 200k 2M 20M 200m 2u 200n Cx 10A 20n 2n m 20m 2m A ma Lx kHz COM V V CAT II V Hz 1000V 700V Figure 14 ⑴. Set the range switch at the desired hfe range position. Test as shown Figure14. ⑵. You can get a reading from LCD display. 32

37 User Maintenance Replacing the Batteries If the meter display on LCD, the battery must be replaced to maintain proper operation. Following procedure to replacing the battery:. Press POWER key to OFF. Disconnect test leads from any live source and remove the test leads from the input terminals. ⑵. Remove the two special screws on the battery cover and open the cover. ⑶. Remove the exhausted battery and replace with a new 9V battery (IEC6F22 JIS006P NEDA1604 type). ⑷. Don t use the meter before the batter cover is in place and fastened fully. 33

38 Replacing the Fuses Following procedure to replacing the fuse:. Press POWER key to OFF. And disconnect test leads from any live source and remove the test leads from the input terminals. ⑵. Remove the two screws on the battery cover and open the cover. ⑶. Remove the blown fuse and replace with fuse of the same size and rating. Make sure the new fuse is centered in the fuse holder. ⑷. The ma input terminal is protected by F0.5A/250V fast blow ceramic fuse, Φ5 20. The A input terminal is protected by F10A/250V fast blow ceramic fuse, Φ ⑸. Don t use the meter before the batter cover is in place and fastened fully. 34

39 Others. Clean your digital multimeter with a damp cloth and mild detergent. Do not use abrasives, solvents, or alcohol. ⑵. If any faults or abnormalities are observed, the meter can not be used any more and it has to be checked out. 35

40 Specifications General Specifications Maximum voltage between terminals and earth ground: 1000V. Display: 1999 counts, automatic polarity. And 40 segments bar graph. Over range: OL will be displayed. Low battery: will be displayed Updates: approx. 3 times per second. Data hold Back light Power supply: 9V IEC6F22, JIS006P, NEAD1604 type. Temperature: operating 0~40 C Storage -10~50 C Relative humidity: 20~80%RH Safety: Designed to IEC1010_ V CAT. Size: (mm). 36

41 Resolution and Accuracy Accuracy is given as ±(%reading +digits) at 18~28, relative humidity up to 80%. All specifications assume less than 1 year. ⑴. DC Voltage Range 200mV Resolution 0.1mV Accuracy (%rdg + digits) 2V 0.001V 20V 0.01V ±(0.5%+3) 200V 0.1V 1000V 1V ±(0.8%+3) Input impedance: 10MΩ Overload protection: DC1000V or AC700V 37

42 . AC Voltage Range 200mV Resolution 0.1mV 2V 0.001V 20V 0.01V 200V 0.1V Accuracy (%rdg + digits) ±(1.0 %+5) 700V 1V ±(1.2%+5) Input impedance: 10MΩ Frequency range: 40~400Hz. Overload protection: DC1000V or AC700V ⑶. DC Current Range 2mA 20mA Resolution 0.001mA 0.01mA Accuracy (%rdg + digits) ±(1.0%+3) 200mA 0.1mA ±(1.5%+5) 10A 0.01A ±(2.0%+5) Overload protection: ma --- F0.5A/250V Fuse A ---- F10A/250V Fuse 38

43 . AC Current Range 2mA 20mA Resolution 0.001mA 0.01mA Accuracy (%rdg + digits) ±(1.2%+5) 200mA 0.1mA ±(2.0%+5) 10A 0.01A ±(3.0%+5) Overload protection: ma --- F0.5A/250V Fuse A ---- F10A/250V Fuse Frequency range: 40~400Hz. ⑸. Resistance Range 200Ω 0.1Ω 2kΩ 20kΩ 200kΩ 2MΩ Resolution 0.001kΩ 0.01kΩ 0.1kΩ 0.001MΩ Accuracy (%rdg + digits) ±(1.0%+3) 20MΩ 0.01MΩ 200MΩ 0.1MΩ ±(5.0%+3) Open circuit voltage: 0.45V; Overload protection: 250Vp 39

44 . Capacitance Range 2nF 20nF 200nF 2μF 20μF Resolution 0.001nF 0.01nF 0.1nF 0.001μF 0.01μF Accuracy (%rdg + digits) ±(4.0%+5) ⑺. Inductance Range Resolution 2mH 0.001mH 20mH 0.01mH 200mH 0.1mH 2H 0.001H 20H 0.01H Accuracy (%rdg + digits) ±(4.0%+5) Overload Protection: F 200mA/250V fuse (quick acting, resistance 1Ω) Tested Inductance: Q 10,Internal impedance 1kΩ 40

45 . Frequency Range Resolution Accuracy (%rdg + digits) 20kHz 0.01kHz ±(1.5%+5) Sensitivity: 250mV rms and input no more 10V rms Overload Protection: 250V ⑼. Temperature Range Resolution Accuracy (%rdg + digits) -20~ ±(3.0%+3) Overload Protection: ma ---- F0.5A/250V ⑽. Transistor Range Function Display: read approximate hfe value hfe (0-1000) of transistor under test (ALL TYPE) Base Current: approx. 10µA,Vce: approx. 2.8V 41

46 . Diode Range Resolution Function 1mV Forward DC Current: approx. 1mA Reversed DC Voltage: approx.2.8v Display :read approximate forward voltage of diode Overload Protection: 250V DC or rms AC ⑿. Continuity Range Function Built-in buzzer will sound, if resistance is lower than 50Ω. Open circuit voltage: approx. 2.8V Overload Protection: 250V DC or rms AC ⒀. TTL Logic Range Function When logic level is less or on 0.8V, LCD displays and the buzzer produces sound. When logic level is more and on 2.0V, LCD displays. Overload Protection: 250V DC or rms AC 42

47

48 HYS005129

Model UT33A: OPERATING MANUAL Table of Contents (1)

Model UT33A: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation

More information

UT202A Operating Manual. Contents

UT202A Operating Manual. Contents Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols

More information

Manual Ranging MultiMeter

Manual Ranging MultiMeter Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!

More information

Model UT201/202: OPERATING MANUAL. Table of Contents

Model UT201/202: OPERATING MANUAL. Table of Contents Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness

More information

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL

Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS

More information

AutoRanging Digital MultiMeter

AutoRanging Digital MultiMeter Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons Measurement Operation A. DC

More information

Model UT58A/B/C: OPERATING MANUAL

Model UT58A/B/C: OPERATING MANUAL Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols

More information

User's Guide. True RMS Industrial Multimeter

User's Guide. True RMS Industrial Multimeter User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),

More information

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents P/N:110401103671 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons

More information

Table of Contents. Page 3 4 5 6 8 9 10 11 13 13 14 16 17 19

Table of Contents. Page 3 4 5 6 8 9 10 11 13 13 14 16 17 19 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Multimeter Structure Functional Buttons Display Symbols Measurement

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

7 FUNCTION DIGITAL MULTIMETER

7 FUNCTION DIGITAL MULTIMETER 7 FUNCTION DIGITAL MULTIMETER 90899 OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools. All rights

More information

72-7730 72-7732 Intelligent Digital Multimeters

72-7730 72-7732 Intelligent Digital Multimeters 72-7730 72-7732 Intelligent Digital Multimeters Model 72-7730/72-7732 OPERATING MANUAL TABLE OF CONTENTS CHAPTER TITLE PAGE 1. Before You Start Overview Inspection Safety Information Rules For Safe Operation

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

10 Multimeter. Users Manual

10 Multimeter. Users Manual 10 Multimeter Users Manual 1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. 10 MULTIMETER m m Mk SELECT RANGE OFF VDC VAC

More information

Model UT60A: OPERATING MANUAL. Table of Contents. Page 3 4 5 6 8 9 10 11 14 17 17 17 19 19

Model UT60A: OPERATING MANUAL. Table of Contents. Page 3 4 5 6 8 9 10 11 14 17 17 17 19 19 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols Measurement

More information

Seven function digital multimeter

Seven function digital multimeter Seven function digital multimeter 98025 Set up And Operating Instructions Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com

More information

User Guide. Model 380260 Insulation Tester / Megohmmeter

User Guide. Model 380260 Insulation Tester / Megohmmeter User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity

More information

Model UT71A/B OPERATING MANUAL

Model UT71A/B OPERATING MANUAL Model UT71A/B OPERATING MANUAL CHAPTER TITLE PAGE 1. 2. Before You Start Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Getting Acquainted Turning

More information

DIGITAL MULTIMETER OPERATION MANUAL ITEM 98674 DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER OPERATION MANUAL ITEM 98674 DIGITAL MULTIMETER CONTENTS CONTENTS ITEM 98674 OPERATION MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DOS AND DON TS 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 4 2. DESCRIPTION 6 2.1 NAMES OF PARTS 7 2.2 SWITCH, BUTTONS AND

More information

User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300

User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300 User Guide 4 wire Earth Resistance Tester Model GRT300 Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according

More information

How To Use A Cdm250 Digital Multimeter

How To Use A Cdm250 Digital Multimeter User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this

More information

323/324/325. Calibration Manual. Clamp Meter

323/324/325. Calibration Manual. Clamp Meter 323/324/325 Clamp Meter Calibration Manual February 2013 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

HVAC Clamp Meter. Users Manual

HVAC Clamp Meter. Users Manual 902 HVAC Clamp Meter Users Manual PN 2547887 May 2006 Rev. 1, 3/07 2006-2007 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies. LIMITED

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

Model UT713 OPERATING MANUAL

Model UT713 OPERATING MANUAL Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC

More information

i410/i1010 AC/DC Current Clamp

i410/i1010 AC/DC Current Clamp /i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating

More information

HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech

HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech HOW TO USE MULTIMETER COMPILE BY: Dzulautotech 1. GENERAL Electricity is absolutely necessary for an automobile. It is indispensable when the engine is started, the air fuel mixture is ignited and exploded,

More information

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter mm AVO410 Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter User manual Bedienungsanleitung Manuel utilisateur Guía del usuario Gebruikershandleiding

More information

Ground Resistance Clamp On Tester

Ground Resistance Clamp On Tester USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground

More information

INTRODUCTION SAFETY PRECAUTIONS/

INTRODUCTION SAFETY PRECAUTIONS/ Title Page No. INTRODUCTION..................................1 SAFTY PRCAUTIONS/WARNINGS.................1 SPCIFICATIONS................................3 CONTROLS AND INDICATORS......................6

More information

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one. 1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter

More information

Table of Contents. Page No.

Table of Contents. Page No. Table of Contents Title Page No. INTRODUCTION... 2 SAFETY PRECAUTIONS/S... 2 SPECIFICATIONS... 3 CONTROLS AND INDICATORS... 8 TESTING PROCEDURES... 10 AUXILIARY FUNCTIONS... 17 BATTERY AND FUSE REPLACEMENT...

More information

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12 Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of

More information

ABCs of DMMs Multimeter features and functions explained Application Note

ABCs of DMMs Multimeter features and functions explained Application Note ABCs of DMMs Multimeter features and functions explained Application Note Digital multimeters offer a wide selection of features. Choosing the right meter for the job can be challenging unless you know

More information

Hygro-Thermometer + InfraRed Thermometer Model RH101

Hygro-Thermometer + InfraRed Thermometer Model RH101 User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative

More information

Table of Contents. Title

Table of Contents. Title Table of Contents Title Page No. INTRODUCTION... 2 SAFETY PRECAUTIONS/WARNINGS... 2 SPECIFICATIONS... 3 CONTROLS AND INDICATORS... 8 TESTING PROCEDURES... 10 AUXILIARY FUNCTIONS... 17 BATTERY AND FUSE

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE Warning...................................... Caution.............................................. Safety Alert Symbol : READ and UNDERSTAND

More information

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...

More information

Model 77 Series IV Digital Multimeter

Model 77 Series IV Digital Multimeter Model 77 Series IV Digital Multimeter Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration adjustment procedures unless qualified to do so. The

More information

115C and 117C. True-rms Multimeters. Users Manual

115C and 117C. True-rms Multimeters. Users Manual 115C and 117C True-rms Multimeters Users Manual PN 2538695 July 2006, Rev. 1, 2/07 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective

More information

Dual Display Digital Multimeter

Dual Display Digital Multimeter Dual Display Digital Multimeter GDM-8246 GW INSTEK PART NO. 82DM-82460MG1 This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual

More information

What is a multimeter?

What is a multimeter? What is a multimeter? A multimeter is a devise used to measure voltage, resistance and current in electronics & electrical equipment It is also used to test continuity between to 2 points to verify if

More information

T+ and T+ PRO Electrical Tester

T+ and T+ PRO Electrical Tester T+ and T+ PRO Electrical Tester Instruction Sheet Introduction The Fluke T+ and T+ PRO Electrical Testers (the Tester ) have the following features: AC and dc voltage measurement, 12 V to 600 V, with or

More information

Users Manual. ProcessMeter

Users Manual. ProcessMeter 787 ProcessMeter Users Manual April 1997, Rev.3, 12/01 1997, 1898, 2000, 2001 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. LIMITED

More information

Essential Electrical Concepts

Essential Electrical Concepts Essential Electrical Concepts Introduction Modern vehicles incorporate many electrical and electronic components and systems: Audio Lights Navigation Engine control Transmission control Braking and traction

More information

Model 1756 Test Lead Kit

Model 1756 Test Lead Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you

More information

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03

Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,

More information

1587/1577. Insulation Multimeters. Users Manual

1587/1577. Insulation Multimeters. Users Manual 1587/1577 Insulation Multimeters Users Manual PN 2401027 April 2005 2005 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies. LIMITED WARRANTY

More information

Multimeter with Temperature

Multimeter with Temperature 16 Multimeter with Temperature P Read First: Safety Information Instruction Sheet To ensure that the meter is used safely, follow these instructions: Do not use the meter if the meter or test leads appear

More information

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1

More information

User s Manual Before using the inverter, you need to read and save the safety instructions.

User s Manual Before using the inverter, you need to read and save the safety instructions. User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information

More information

Integrating Sound Level Meter and Datalogger

Integrating Sound Level Meter and Datalogger USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,

More information

RS DIGITAL THERMOMETER

RS DIGITAL THERMOMETER RS DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL C F MX MN AVG TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION... 1 2. SPECIFICATIONS... 1 3. NAME OF PARTS AND POSITIONS... 3 4. OPERATION INSTRUCTIONS... 5

More information

Fluke 3000 FC Series Test Tools Technical Data

Fluke 3000 FC Series Test Tools Technical Data Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect

More information

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller 12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Ground Resistance Clamp-On Tester

Ground Resistance Clamp-On Tester User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 82IP-303A0ME E1 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

The Basics of Digital Multimeters

The Basics of Digital Multimeters IDEAL INDUSTRIES INC. The Basics of Digital Multimeters A guide to help you understand the basic Features and Functions of a Digital Multimeter. Author: Patrick C Elliott Field Sales Engineer IDEAL Industries,

More information

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions) ENGLISH (Original instructions) INSTRUCTION MANUAL Radio BMR00 WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Symbols The following show

More information

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL 162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION

More information

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES

INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES CONTENTS / EN CONTENTS Title Page I. SAFETY INFORMATION...1 II. INTRODUCTION...3 III. SPECIFICATIONS...4 3-1 Environmental Conditions...4

More information

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN User's Guide Digital Psychrometer Model RH390 MAX MIN F C WBT Dew Point Introduction Congratulations on your purchase of the Extech RH390 Digital Psychrometer. This device measures Humidity, Air Temperature,

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

Multifunction Process Calibrator

Multifunction Process Calibrator 725 Multifunction Process Calibrator Product Overview PN 1549644 English January 2000 Rev.2, 8/05 2000-2005 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter AMP-210 AMP-210-EUR 600A AC TRMS Clamp Multimeter AMP-220 AMP-220-EUR 600A AC / DC TRMS Clamp Multimeter AMP-310 AMP-310-EUR 600A AC TRMS Clamp Multimeter AMP-320 AMP-320-EUR 600A AC / DC TRMS Clamp Multimeter

More information

Table of Contents Title Page No.

Table of Contents Title Page No. Table of Contents Title Page No. INTRODUCTION..................................2 SAFTY PRCAUTIONS/WARNINGS.................2 SPCIFICATIONS................................3 CONTROLS AND INDICATORS......................8

More information

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Technical Note Freedom/Fleet Power 512-0084-01-01 Rev 1 Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers Overview This document is a guide for troubleshooting inverters, battery chargers,

More information

Model 187 & 189. Users Manual. True RMS Multimeter

Model 187 & 189. Users Manual. True RMS Multimeter Model 187 & 189 True RMS Multimeter Users Manual ugust 2000, Rev.2, 6/02 2000, 2002 Fluke Corporation. ll rights reserved. Printed in U.S.. ll product names are trademarks of their respective companies.

More information

RADIANT PLASMA 4700 Plasma Spark Generator

RADIANT PLASMA 4700 Plasma Spark Generator RADIANT PLASMA 4700 Plasma Spark Generator Installation Guide / User Manual A S P A R K O F F R E S H A I R Aquapulser.com Contents 1 Introduction 2 1.1 About the Product....................................

More information

Technical Note Series

Technical Note Series Technical Note Series SKIN CONDUCTANCE SENSOR (SA9309M) S TN0 0 0 8-0 0 S k i n C o n d u c t a n c e S e n s o r Page 2 IMPORTANT OPERATION INFORMATION WARNING Type BF Equipment Internally powered equipment

More information

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter ELECTRICAL INSTRUMENT AND MEASUREMENT Electrical measuring instruments are devices used to measure electrical quantities such as electric current, voltage, resistance, electrical power and energy. MULTIMETERS

More information

Multi Media Cable Tester TM-901N/TM-902/TM-903

Multi Media Cable Tester TM-901N/TM-902/TM-903 Multi Media Cable Tester TM-901N/TM-902/TM-903 User Manual HB2TM9020010 TENMARS ELECTRONICS CO., LTD Table of Contents 1 Introduction... 1 2 Safety Precaution... 1 3 The verifier does the following:...

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

Loop Calibration and Maintenance

Loop Calibration and Maintenance Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains

More information

Thermistor Thermometer MODEL NO. 93210-00

Thermistor Thermometer MODEL NO. 93210-00 Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:

More information

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide Verify that you received the following items in the shipment of your handheld scope: 1 Power cable 1 Li-Ion battery pack, 10.8 V (included

More information

AC Direct Off-Line Power Supplies

AC Direct Off-Line Power Supplies AC Direct Off-Line Power Supplies r Introduction Many DC power supplies found in electronic systems, including those in this Tech School, rectify the 120 volts available at an electric outlet. The initial

More information

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Agilent U1230 Series Handheld Digital Multimeters (DMMs) Agilent U1230 Series Handheld Digital Multimeters (DMMs) Data Sheet Retool your expectations with the new Agilent U1230 Series Handheld DMMsthe first to combine a built-in LED flashlight, both audible

More information

How To Use A Power Supply Unit (Upu)

How To Use A Power Supply Unit (Upu) BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and

More information

MODEL 2202IQ (1991-MSRP $549.00)

MODEL 2202IQ (1991-MSRP $549.00) F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

PR-D9W. GB Version 1

PR-D9W. GB Version 1 PR-D9W Version 1 Table of contents Important safety instructions... 2-3 Introduction... 4 Controls... 5-8 Using your weather alert radio for the first time... 9 Operating your radio Search tuning AM/FM...

More information

Achat 115MA full-range speaker. user manual

Achat 115MA full-range speaker. user manual Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

ECO SENSORS, INC. OZONE SENSOR AND MONITOR ECO SENSORS, INC. OZONE SENSOR AND MONITOR Model A-22 11-07 INSTRUCTIONS FOR USE Sensor Rubber boot to protect against mechanical damage. Data and power jacks on the side. SM-X precalibrated sensor module.

More information

Fundamentals of Signature Analysis

Fundamentals of Signature Analysis Fundamentals of Signature Analysis An In-depth Overview of Power-off Testing Using Analog Signature Analysis www.huntron.com 1 www.huntron.com 2 Table of Contents SECTION 1. INTRODUCTION... 7 PURPOSE...

More information

AGILENT E5071C ENA NETWORK ANALYZER

AGILENT E5071C ENA NETWORK ANALYZER AGILENT E5071C ENA NETWORK ANALYZER Flow Diagram of Procedure The operational flow of the software is depicted by the flowchart shown below. Basic Calibration Before executing calibration, you need to

More information

www.elektroexpressz.hu

www.elektroexpressz.hu www.elektroexpressz.hu 2013 1 UT10 SERIES / UT20 SERIES Modern Pocket - Size Digital Multimeters Pocket-Size Digital Multimeters UNI-T UT10A UT10A DC Voltage 400mV/4V/40V/300 ±(0.8%+1) AC Voltage 4V/40V/300V

More information

Digital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester

Digital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,

More information

Benchtop Computer Monitor Generator

Benchtop Computer Monitor Generator Model: 1280B Benchtop Computer Monitor Generator USER MANUAL Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of

More information

Lab E1: Introduction to Circuits

Lab E1: Introduction to Circuits E1.1 Lab E1: Introduction to Circuits The purpose of the this lab is to introduce you to some basic instrumentation used in electrical circuits. You will learn to use a DC power supply, a digital multimeter

More information