10 seconds is all you need to assign a room thermostat to the Master Controller.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "10 seconds is all you need to assign a room thermostat to the Master Controller."

Transcription

1 MAKInG MoDeRn LIVInG PossIBLe application guide simple to install. a pleasure to use. cf2 + wireless Floor heating and cooling control. made beautifully simple. 10 seconds is all you need to assign a room thermostat to the Master Controller. cf2.danfoss.com

2 welcome to cf2 + everything about this system has been designed for simplicity, both during installation and in operation. With its highly reliable and easy-to-use 2-way wireless communication, CF2 + is ideally suited to an extremely wide range of applications, from domestic projects to offices, healthcare facilities, hotels or public buildings. In this short application guide, we show you just some of the many applications that CF2 + can be used for, with convenient headings to help you decide which configuration is best for your project. once you have decided on your system, you can use the relevant table to choose the ideal combination of products. As simple as that. We very much hope that this guide will be helpful, and thank you for considering Danfoss. Danfoss Hydronic Floor Heating 2 CF2 + Wireless Floor Heating and Cooling Control

3 Contents 4 Floor heating system with condensing boiler and mixing shunt 11 2-pipe automatic Floor heating cooling change over system 5 Floor heating system with condensing boiler and wireless relay 12 3-pipe automatic Floor heating cooling change over system 6 combined Floor heating and radiator system with condensing boiler and mixing shunt 13 3-pipe automatic Floor heating cooling change over system and wireless chiller relay 7 8 maximum configuration up to 30 rooms and/or 45 actuators Floor heating system with heat pump or other sustainable heat source pipe automatic Floor heating cooling change over system and dew point sensor 4-pipe automatic Floor heating cooling change over system 9 Floor heating system with mixing valve tvm-h 17 Flip-out product overview 10 weather compensated Floor heating system connected to district heating cf2.danfoss.com 3

4 Floor heating system with condensing boiler and mixing shunt 1 and 2 family houses, new build and renovation.» temperature controlled per room» energy savings on heat production and pump energy Mixing shunts» FHM» In this basic application the temperature in each room is controlled by a CF-R room thermostat.» every 5 minutes the CF-MC Master Controller receives a signal from each of the CF-R Room thermostats. the signal contains information about the actual and desired room temperature. the CF-MC Master Controller signals to the room thermostats that the message was received (2-way communication).» When there is a heat demand, the room thermostat communicate to the Master Controller. It opens the assigned actuator(s) and provide water to flow through the rooms heating circuit(s).» the flow temperature is controlled by the mixing shunt.» on heat demand the pump and boiler will automatically be activated.» When the desired room temperature is reached, the Master Controller will close the actuator(s) and stop the flow.» the boiler and pump will automatically be turned off. product type need optional thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds 4 CF2 + Wireless Floor Heating and Cooling Control

5 Floor heating system with condensing boiler and wireless relay 1 and 2 family houses, new build and renovation.» temperature controlled per room» energy savings on heat production and pump energy» Wireless solution for boiler control Mixing shunts» FHM Floor heating pipes» FH» the basic application idea is identical to the previous application with condensing boiler and mixing shunt. A few differences are:» the heat demand is also sent to the Wireless Relay.» the Wireless Relay activates the boiler which is installed in another room.» the boiler will be turned off when the heat demand is cancelled. thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds cf2.danfoss.com 5

6 combined Floor heating and radiator system with condensing boiler and mixing shunt 1 and 2 family houses, new build and renovation.» temperature controlled per room» energy savings on heat production and pump energy» Floor heating and radiator heating controlled by 1 system Mixing shunts» FHM Radiator accessories» RA / RLV» one Master Controller is installed to control both floor heating and radiators.» Radiators need to be supplied via a separate manifold directly connected to the boiler supply and return.» every single Master Controller output can be defined as floor or radiator via the CF-RC Remote Controller. this ensures optimal regulation, right supply temperature, comfort and energy savings.» the circulation pump from the mixing shunt will be activated on heat demand from the floor defined rooms.» the flow temperature for floor heating is controlled by the mixing shunt. the flow temperature for the radiators is depending on boiler settings.» the boiler will be activated on both floor and radiator defined rooms heat demand. thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds 6 CF2 + Wireless Floor Heating and Cooling Control

7 maximum configuration up to 30 rooms and/or 45 actuators bigger sized houses, new build, renovation and light commercial buildings.» temperature controlled per room» energy savings on heat production and pump energy» optimal solution for bigger sized houses and buildings Mixing shunts» FHM» For bigger installations it is possible to combine up to three CF-MC Master Controllers to function as one system.» one Master Controller is defined as Master via the CF-RC Remote Controller. the second and third Master Controller are defined as slaves and communicate with the Master wirelessly.» Maximum configuration is capable of operating up to 30 rooms with up to 45 circuits» the system can be controlled from one CF-RC. every single output can be defined as floor or radiator. this ensures optimal regulation, right supply temperature, comfort and energy savings.» the pump and boiler relays can have a common setting or can be configured individually for each CF-MC.» optimal solution for bigger houses and light commercial (e.g. offices) or public buildings (e.g. schools). thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds cf2.danfoss.com 7

8 Floor heating system with heat pump or other sustainable heat source 1 and 2 family houses, new build and renovation.» temperature controlled per room» energy savings on heat production» Increase in heatpump efficiency and life time value» Reduced need for a buffer tank or by-pass valve Heatpumps» DHP» no need for a mixing shunt to control flow temperature.» special Low energy optimizer feature optimizes control when sustainable heat sources (e.g. heat pump) are used.» Low energy optimizer feature intelligently distributes the heat in a way ensuring smooth and stable flow over the time by opening actuators one at a time. this protects the heat pump against short working cycles (minimizing the number of starts/stops).» the feature reduces the need for a buffer tank or by-pass valve. thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds 8 CF2 + Wireless Floor Heating and Cooling Control

9 Floor heating system with mixing valve tvm-h 1 and 2 family houses, new build and renovation.» temperature controlled per room» energy savings on heat production and pump energy» Cheaper solution for price sensitive projects Mixing Valves» tvm-h» In this application the mixing shunt from the basic application with condensing boiler is substituted by a simple mixing valve.» the thermostatic mixing valve can be set to a desired maximum flow temperature.» the outlet temperature of the mixing valve is kept on a constant level at all times.» the pump from the mixing shunt is replaced by a separate pump which is also controlled via the Master Controller. thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds cf2.danfoss.com 9

10 weather compensated Floor heating system connected to district heating where to use 1 and 2 family houses, new build and renovation.» temperature controlled per room» energy savings on heat production and pump energy» outdoor temperature compensation» Additional energy savings Mixing shunts» FHM Weather Compensators» ecl Actuators» ABV-nC temperature sensors» esm» the District Heating network provides the installation with heating water.» normally floor heating mixing shunts are set to one mixing temperature setting for all year use.» It is possible to easy upgrade all FHM-C Mixing shunts with an ecl Weather Compensator. the weather compensator controls the supply temperature for the floor heating based on the outdoor temperature.» ecl combined with a ABV thermal Actuator automatically ensures that supply temperature is kept at minimum level all year around and thereby energy is automatically saved. thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds 10 CF2 + Wireless Floor Heating and Cooling Control

11 2-pipe automatic Floor heating cooling change over system Multi family houses, new build, renovation and light commercial buildings.» Floor heating and cooling automatically controlled» no user interaction needed» Used in applications with a central change-over between heating and cooling on primary side of the system.» Depending on the supply temperature which is measured by the Pipe sensor the Master Controller will automatically switch between heating and cooling mode.» the Pipe sensor is mounted to the supply pipe and connected to the Master Controller.» the desired change-over temperature can be defined via CF-RC. thermostats CF-R s P/D/F wireless relay CF-WR dew point sensor CF-Ds *) *) It is highly recommended to use a Dew Point sensor in all applications with cooling involved. cf2.danfoss.com 11

12 3-pipe automatic Floor heating cooling change over system Multi family houses, new build and renovation and light commercial buildings.» end user can decide on floor heating cooling change over temperature» Possibility to exclude some rooms from the cooling Valves» RA-C, RA-G Actuators» twa-a» Instead of centrally operated heating cooling change over it is possible to have end user decide on heating or cooling mode.» Via CF-RC it is possible to define one of the standard CF-RD thermostats as a Master thermostat to sequential control of heating and cooling stages according to the room temperature where it is placed. As long as the measured temperature is lower than the desired temperature the operation mode is heating. When the measured temperature is higher than the desired temperature the operation mode is cooling.» It is possible to overrule the automatic change over to a manual change over.» to prevent constant change between heating and cooling mode an adjustable neutral zone for 2K or 4K is integrated.» 2 Master Controller outputs for actuators controlling supply heating and cooling pipes can be defined via CF-RC Remote.» It is possible to redefine the pump relay on the CF-MC Master Controller to control a chiller (if change between boiler and chiller is needed).» to inform end users on the operation mode a heating/cooling indicator on the CF-RD master thermostat display is included. thermostats CF-R D (as master) s/p/f wireless relay CF-WR dew point sensor CF-Ds *) *) It is highly recommended to use a Dew Point sensor in all applications with cooling involved. 12 CF2 + Wireless Floor Heating and Cooling Control

13 3-pipe automatic Floor heating cooling change over system and wireless chiller relay Multi family houses, new build, renovation and light commercial buildings.» end user can decide on floor heating cooling change over temperature» Possibility to exclude some rooms from the cooling» easy integration of remote situated chiller for cooling Valves» RA-C, RA-G Actuators» twa-a» the basic application idea is identical to the previous application for 3-pipe automatic change over systems. A few differences are:» the Wireless Relay CF-WR can be defined to control a chiller. It can be used to operate the valve on supply pipe from the chiller.» the valve on the heating supply pipe from boiler can be operated by the boiler relay on the CF-MC Master Controller.» the 2 Master Controller outputs are not used to control supply actuators and therefore can be used as floor heating cooling outputs. products type need need thermostats CF-R D (as master) s/p/f wireless relay CF-WR dew point sensor CF-Ds *) *) It is highly recommended to use a Dew Point sensor in all applications with cooling involved. cf2.danfoss.com 13

14 3-pipe automatic Floor heating cooling change over system and dew point sensor Multi family houses, new build, renovation and light commercial buildings.» end user can decide on floor heating cooling change over temperature» Possibility to exclude some rooms from the cooling» Build in protection against condensation in cooling operation mode Valves» RA-C, RA-G Actuators» twa-a» the basic application idea is identical to the previous applications for 3-pipe automatic change over systems. A few differences are:» to protect against condensation a CF-Ds Dew Point sensor is mounted on the supply pipe from the chiller.» It is possible to redefine output no. 5 on the CF-MC Master Controller to provide 24V dc power supply to the CF-Ds dew point sensor.» the CF-Ds dew point sensor needs to be connected to the global stand-by input on the CF-MC Master Controller. thermostats CF-R D (as master) s/p/f wireless relay CF-WR dew point sensor CF-Ds 14 CF2 + Wireless Floor Heating and Cooling Control

15 4-pipe automatic Floor heating cooling change over system Multi family houses, new build and renovation and light commercial buildings.» end user can decide on floor heating cooling change over temperature» Possibility to exclude some rooms from the cooling» separated heating and cooling supply and return system Valves» RA-C, RA-G Actuators» twa-a» Instead of centrally operated heating cooling change over it is possible to have end user decide on heating or cooling mode.» Via CF-RC it is possible to define one of the standard CF-RD thermostats as a Master thermostat to sequential control of heating and cooling stages according to the room temperature where it is placed.» As long as the measured temperature is lower than the desired temperature the operation mode is heating.» When the measured temperature is higher than the desired temperature the operation mode is cooling.» to prevent constant change between heating and cooling mode an adjustable neutral zone for 2K or 4K is integrated.» Up to 4 CF-MC Master Controller outputs for actuators controlling the supply/return pipes can be defined via the CF- RC Remote Controller.» It is possible to redefine the pump relay on the CF-MC Master Controller to control a chiller.» to protect against condensation a CF-Ds Dew Point sensor can be mounted on the supply pipe from the chiller.» to inform end users on the operation mode a heating/cooling indicator on the CF-RD Master thermostat display is included. thermostats CF-R D (as master) s/p/f wireless relay CF-WR dew point sensor CF-Ds *) *) It is highly recommended to use a Dew Point sensor in all applications with cooling involved. cf2.danfoss.com 15

16 many applications + one system

17 CF-RS» 088U0210 Room Thermostat, Standard» temperature setting from 5 35 o C by turning knob CF-RP» 088U0211 Room Thermostat, Public» tamperproof. no direct access to settings» this room thermostat is particularly suited for public and semicommercial installations CF-RD» 088U0214 Room Thermostat, Display» Displays either actual temperature or setting temperature» temperature setting from 5 35 o C by push buttons» Can be set as Master to control heating-cooling change over temperature» symbols indicating e.g. setback/timer function, heating, cooling» electronic limitation of min./max. room temperature via menu on display» Alarm icons and error codes in display, e.g. low battery indicator CF-RF» 088U0215 Room Thermostat, Infrared Floor Sensor this room thermostat includes most of the features of the CF-RD plus» Measures the floor surface temperature by Infrared Floor sensor» Regulates the room temperature according to min. and max. floor temperature settings» Icon in display for floor sensor CF-RC» 088U0221 Remote Controller» Wireless connection to all CF2 components via Master Controller» temperature setback program for zone control of up to 6 zones and period programming for energy saving during holidays etc.» Alarm log and easy failure identification» Individual setting of each output on Master Controller for either floor heating or radiator system» Forecast function in relation to night setback» Advanced settings for cooling and Heat Pump applications» And lot of other features included CF-RU» 088U0230 Repeater Unit» the Repeater Unit extends the wireless transmission range to the Master Controller from Room thermostats» If e.g. a Room thermostat is out of reach of the Master Controller, the Repeater Unit will repeat the wireless signal, thus re-establishing connection CF-DS» 088U0251 Dew Point Sensor» Cooling without condensation CF-WR» 088U0252 Wireless Relay» Flexible installation no wiring» extra relay for controlling Condensing Boiler, Chiller or Pump ESM-11» 087B1165 Pipe Sensor» simple solution for automatic heating cooling change over in 2-pipe systems TWA-A» 088H3110 Thermal Actuator» For Danfoss RA valves with 22 mm connection» For Danfoss FHF manifolds with 22 mm connection TWA-K» 088H3140 Thermal Actuator» For non Danfoss valves with M30x1.5 connection» For non Danfoss manifolds with M30x1.5 connection CF-EA» 088U0250 External Antenna» Recommended when Master Controller is mounted in or close to a metal cabinet/box» 2 meter cable CF-EC» 088U0255 Extended Antenna Cable» 5 meter cable Master Controller CF-MC 10 outputs» 088U outputs» 088U0245» 2-way wireless transmission at 868 MHz» LeD indicator for status on each output» Wireless installation of room thermostats and other system components» 24 V short-circuit protected outputs» Versions with 5 and 10 outputs available» Regulation by PWM (Pulse Width Modulation) principle» two separate relays for both pump and boiler control» Actuator outputs accommodate several cable types for easy cable fixing and strain relief» Automatic self diagnosis program with error indication» optional heating/cooling switch» Connections for Dew Point sensor and Pipe sensor

18 MAKInG MoDeRn LIVInG PossIBLe cf2 + intuitive simple beautiful proven experience Danfoss have been innovating heating systems for over 75 years and have over 10 years experience with wireless floor heating controls. Danfoss has been designing and developing heating control systems for over 75 years and we have over 10 years experience in advanced wireless solutions. throughout that time, it has been our goal to simplify both installation and operation to ensure maximum end user value and energy savings. While making your job as an installer both easier and more satisfying. With the development of the CF2 + system, we believe that we have set a whole new standard of functionality while radically simplifying installation, ease of use and energysaving potential. to support this, we have e.g. created enhanced information and technical tools, including videos showing how to install the system correctly and clear, informative technical specification sheets. And with our international sales, service and technical support network, you can rely on Danfoss to ensure satisfied customers every time. CF2 + Floor Heating and Cooling Control. Made beautifully simple. Learn more scan the QR code to view our installation video. Beautifully simple. vbspq102 pravda.dk

HCE80/HCC80/HCE80R/HCC80R

HCE80/HCC80/HCE80R/HCC80R HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp

More information

Overview - Danfoss Link and living software versions

Overview - Danfoss Link and living software versions Danfoss Link CC Mk II (with minisd card) software..35.3.7.4.5 0--00 The initial Danfoss Link CC software: Supports all features from the original Devilink software. New functionality providing control

More information

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar

More information

RF 1. Contents: Connecting diagram. Detailed information:

RF 1. Contents: Connecting diagram. Detailed information: Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Everything you need to help your heating business grow

Everything you need to help your heating business grow Everything you need to help your heating business grow Because we can deliver everything you need from a single source, we make it easy for you to provide your customers with the best indoor and outdoor

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...

More information

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions

RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions RVR Hybrid System Controller Installation Instructions 1 Introduction to Hybrid Systems The RVR Hybrid system uses a combination of the Immergas Audax range of heat pumps with gas or oil boilers to create

More information

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:

More information

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with

More information

Smile. The All-In-One Heating Controller

Smile. The All-In-One Heating Controller Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from

More information

Your tool for designing efficient balancing solutions for heating and cooling systems

Your tool for designing efficient balancing solutions for heating and cooling systems Application guide Your tool for designing efficient balancing solutions for heating and cooling systems 18 applications Our recommended applications for heating and cooling systems will improve comfort

More information

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings. 1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring

More information

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure. LMS The modular management system for condensing boilers Control Products & Systems OEM Answers for infrastructure. LMS advanced electronics and proven software At times of dwindling resources, rising

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Fully Pumped Systems

Fully Pumped Systems Fully Pumped Systems (also see the picture gallery and System Basics) The term for any boiler that uses a pump to move all the heat from the boiler to every part of the system is fully pumped. As a rule

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

Guidance on how to comply with the 2010 Building Regulations Part L

Guidance on how to comply with the 2010 Building Regulations Part L Guidance on how to comply with the 2010 Building Regulations Part L Version 2.0 10 December 2010 This guide supports the official guidance covering the use of controls in boiler based, gas and oil fired

More information

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller Intuitive control TLC 700 The multifunctional controller TLC 700 The intelligent controller for complex systems TEDDINGTON As easy as Teddington air curtain systems are the ultimate when it comes to the

More information

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump. EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS AGRI-ALERT ALARM SYSTEMS Peace of Mind Agri-Alert is a complete alarm system for monitoring temperature, power, feed and watering systems, burglary,

More information

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary

RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary January 2013 TABLE OF CONTENTS INTRODUCTION... 3 GENERAL RECOMMENDATIONS... 3 Communication with customers in the field of environmental sustainability...

More information

Thermostat with display

Thermostat with display H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations

More information

Implementing a Reliable Furnace Monitoring System

Implementing a Reliable Furnace Monitoring System Category: Manufacturing Implementing a Reliable Furnace Monitoring System Products Used: RT Series PXI (PXI 1002 And PXI 8156B) LabVIEW Real-Time by V. Arunachalam Sr. Project Engineer Anand Chinnaswamy

More information

Uponor Smatrix Wave PLUS U@home R-167 INSTALLATION AND OPERATION MANUAL HELP AND TUTORIAL

Uponor Smatrix Wave PLUS U@home R-167 INSTALLATION AND OPERATION MANUAL HELP AND TUTORIAL Uponor Smatrix Wave PLUS U@home R-167 INSTALLATION AND OPERATION MANUAL HELP AND TUTORIAL 09 2015 I Table of contents I Installation and configuration... 3 What is inside your U@home package?...3 U@home

More information

Passion for KNX innovation

Passion for KNX innovation Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can

More information

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump. English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface

More information

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature LHZ USER GUIDE LHZ User Guide LHZ would like to thank you for purchasing your LHZ radiator. You have purchased a high quality, German designed and manufactured heating device, which will give you soft

More information

User Manual THR840DUK Digital Thermostat

User Manual THR840DUK Digital Thermostat User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical

More information

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5

More information

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install

More information

June 27, 2009. Dear Customer,

June 27, 2009. Dear Customer, June 27, 2009 Dear Customer, We are pleased to announce new products and sales tools to help you have even more success with the Pro1 line of professional heating and cooling products. Please review the

More information

Daikin Altherma. hybrid heat pump. The natural combination

Daikin Altherma. hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet

More information

PRODUCT LIST Facility DDC Access WebXL DDC

PRODUCT LIST Facility DDC Access WebXL DDC PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470

More information

Data sheet Thermostatic sensors type RA 2000

Data sheet Thermostatic sensors type RA 2000 Thermostatic sensors type RA 2000 EN 215-1 RA 2990 RA 2992 RA 2920 RA 5060 RA 5074 Application The RA series is a comprehensive programme of radiator thermostats which covers all central and district heating

More information

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control

More information

3466 Building Energy Management Training Systems

3466 Building Energy Management Training Systems 3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

Master & Amplifier For ModuSat Communal Heating

Master & Amplifier For ModuSat Communal Heating Master The ModuSat master controller provides a convenient central point for connection of all ModuSat HIU S on a communal heating scheme. The ModuSat s and master are linked via a hard wired Modbus RS485

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS

HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS PIP301: Blueprint Reading This module covers the basic skills required for interpreting information provided by drawings. These skills are essential in

More information

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu

INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016 Your partner in an automated industry Our combination of technical know-how, product responsibility and on-time deliveries guarantees you the best WHY CHOOSE

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Flush-mounted room thermostats

Flush-mounted room thermostats s 3 076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600 Flush-mounted room thermostats for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment RDF300

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Installation Guide for Hive Active Heating

Installation Guide for Hive Active Heating Installation Guide for Hive Active Heating Important note: Installation should only ever be carried out by a qualified engineer. Technical Support If you need to contact Hive s Technical Support team during

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

Nest Learning Thermostat Installation Guide. Installation step-by-step

Nest Learning Thermostat Installation Guide. Installation step-by-step Nest Learning Thermostat Installation Guide Installation step-by-step Contents Compatibility. 3 In the box. 4 Before you start. 5 Choose an installation method. 6 Replacing an existing wired thermostat.

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

Air Source Heat Pump Installation and Maintenance Manual

Air Source Heat Pump Installation and Maintenance Manual Air Source Heat Pump Installation and Maintenance Manual Model Numbers: RC090MHXEA RC160MHXEA January 2013 www.samsungehs.co.uk Hendra - January 2013 1 The outdoor unit (boiler) Deciding on Where to Install

More information

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units INSTALLATION INSTRUCTIONS OPTION 1xxx 1104_1000_EN Comfort Regulation (Carel pco) Detailed instructions RZAHUC program version 1.1 Regulation for Reznor Air Handling Units INDEX 1. Introduction... 4 1.1.

More information

AMICO Information. Management System (AIMS)

AMICO Information. Management System (AIMS) AMICO Information Management System (AIMS) ALERT- 2 Installation and Maintenance Manual v 2.5 Table of Contents INTRODUCTION...3 Theory of Operation... 3 Network Diagram... 4 INSTALLATION... 5 Medical

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED High Efficiency Condensing Boilers Proven Reliability, American-Made Home Heating Comfort. Look for this logo throughout this literature to see the unique features that set U.S. Boiler Company apart from

More information

Energy efficiency in building automation and control

Energy efficiency in building automation and control Energy efficiency in building automation and control Proven applications for heating and cooling supply Answers for infrastructure. Efficient VAC control protects the environment and increases comfort

More information

LG AIR CONDITIONING SYSTEMS

LG AIR CONDITIONING SYSTEMS LG AIR CONDITIONING SYSTEMS THE NEW STANDARD IN COMFORT INNOVATIVE COMFORT SOLUTIONS AT LG, WE BELIEVE COMFORT SHOULD ALWAYS BE BEAUTIFUL. 4 Table of Contents INTRODUCTION 04-07 ART COOL 08-11 SINGLE

More information

Federation of European Heating, Ventilation and Air-conditioning Associations

Federation of European Heating, Ventilation and Air-conditioning Associations Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 REHVA

More information

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT Motion Detector 360 Degrees 5420/360 Installation Instructions REGISTERED DESIGN REGISTERED PATENT Installation Instructions The Infra-red Monitor Motion Detector from Clipsal provides high performance

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

HEATING, VENTILATION & AIR CONDITIONING

HEATING, VENTILATION & AIR CONDITIONING HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating

More information

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T HMG 6 T 4930240 HME 6 T 4930245 HM 12 T 4940245 Updated: Dec-14 (subject to change) Page 1 of 61 Contents 1 Contents 2 FUNCTIONAL

More information

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES CM927 can be installed without disrupting your room décor as no wiring connection is required between the room unit and the boiler Attractive, slim, ultra-modern

More information

Sanitary Type Electronic Flow Switches

Sanitary Type Electronic Flow Switches Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts

More information

WIRELESS INSTRUMENTATION TECHNOLOGY

WIRELESS INSTRUMENTATION TECHNOLOGY BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904

More information

Retail & Commercial Solutions. Siemens EcoView. Energy Management Made Easier. www.siemens.com/ecoview

Retail & Commercial Solutions. Siemens EcoView. Energy Management Made Easier. www.siemens.com/ecoview Retail & Commercial Solutions Siemens EcoView Energy Management Made Easier www.siemens.com/ecoview Control energy usage. Reduce costs. Introducing Siemens EcoView an easy-to use and affordable end-to-end

More information

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+) 1. In addition to the information scheduled below, the pre-tender designer is responsible for: (i)

More information

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity Theta Dual service BFC, SGE, SGS for 20/0/0 kw heating capacity Module to combine central heating with a high efficiency water heater Plate heat exchanger with DHW pump, three-way mixing valve, control

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No. 910-00009-01 Rev 05. 1.1. Components. 1.2. Prerequisites for Site Survey

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No. 910-00009-01 Rev 05. 1.1. Components. 1.2. Prerequisites for Site Survey 1. Overview The Cypress Envirosystems Wireless Pneumatic Thermostat (WPT) retrofits an existing pneumatic thermostat to provide Direct Digital Control (DDC) like zone control functionality at a fraction

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx 756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang

More information

Brochure 2012-2013.EX

Brochure 2012-2013.EX VERTIGA Brochure 2012-2013.EX VERTIGA The new benchmark for design at super-low water temperatures The ultimate expression of form and function. Vertiga combines the power of Jaga Top Performers, the efficiency

More information

Seeing by Degrees: Programming Visualization From Sensor Networks

Seeing by Degrees: Programming Visualization From Sensor Networks Seeing by Degrees: Programming Visualization From Sensor Networks Da-Wei Huang Michael Bobker Daniel Harris Engineer, Building Manager, Building Director of Control Control Technology Strategy Development

More information

High-efficient gas boiler CompactGas

High-efficient gas boiler CompactGas High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard

More information

Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION

Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION Model: 308-1412 Manual DC: 080215 WIRELESS COLOR FORECAST STATION FRONT VIEW SENSOR TX141TH-Bv2 LED TX Sensor Battery Cover Sensor Battery Compartment 2 AA Buttons Battery Compartment 3 AAA BACK VIEW Battery

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Designer. of control solutions NA O7.124A

Designer. of control solutions NA O7.124A u n i v e r s a l c o m f o r t Designer of control solutions NA O7.124A CONTROL ADAPTED TO THE ENTIRE RANGE V for Vision: Our range of CIAT controls features all the techniques used for air conditioning,

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI Wenjun Zhao Shenzhen Hangsheng Electronics Co., Ltd, Shenzhen 518103, China E-mail: tangwind@gmail.com Abstract In

More information

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS Radiantec ONTROLS FOR RADIANT HEATING GENERAL SUPPLEMENT 410 ONTROLS This supplement presents a layman s language narrative about Radiantec ompany controls, their design and their installation. This supplement

More information

API Marine. BMS Presentation. Ballast Measurement Systems

API Marine. BMS Presentation. Ballast Measurement Systems API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter

More information

HVAC and Lighting Control Products for Open Building Automation Systems

HVAC and Lighting Control Products for Open Building Automation Systems HVAC and Lighting Control Products for Open Building Automation Systems Distech Controls offers an extensive line of feature-rich and cost effective controllers for building automation, covering HVAC

More information

Certified HVAC - Refrigeration Training Program

Certified HVAC - Refrigeration Training Program FINAL CERTIFICATION AWARDED BY IMRTC - USA Certified HVAC - Refrigeration Training Program This highly specialized and concentrated Program is ideally suited to following individuals who: A people who

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information