1 Indirect Calorifiers & Storage Tanks High Performance Stainless Steel and Glass Lined Tanks

2 Hot Water Storage Tanks and Calorifiers The Evinox range of indirect storage tanks feature Stainless Steel and Glass Lined models with capacities ranging from 100 to 5000 litres. Our fast recovery rates, large volumes, and low standby losses provide comfort, convenience, efficiency and reliability. Stainless Steel EBS Twin Coil Tank Features Choice of Stainless Steel or Glass lined tanks Single and twin coil models available. Tanks suitable for commercial and residential applications Capacities from 100 to 5000 Litres Simple installation and maintenance Robust tanks built for high performance and long life Stainless Steel Storage Tanks Our Stainless Steel tank range enables you to store a small amount of hot water but recover it very quickly, providing vast amounts of hot water on demand. When compared with other tanks, the EBS features a larger coil, which ensures rapid recovery. Features EBS Tank Range Choice of 100, 150, 200 and 00 litre single coil tanks, and 200 or 00 litre twin coil models Excellent performance provided via an input coil heat exchanger ensuring very fast recovery rates and exceptional continuous output performance. Tank and integrated coil constructed entirely from 16L austenitic stainless steel to provide durability Quality insulation for minimum heat losses Simple installation and maintenance, with easy-toreach connections, wiring and inspection trap Full WRC and WRAS approval

3 Glass Lined Storage Tanks & Calorifiers Our Glass Lined tank range offers versatility with a large number of models available to suit most systems. Omicron single coil tanks offer capacities from 500 to 5000 litres Omega twin coil tanks provide capacities from 500 to 5000 litres Series Y range designed for use with heat pumps and condensing boilers Series BF calorifiers offer large capacities up to 5000 litres High performance tanks suitable for large DHW demands 50 or 100mm CFC free insulation minimises heat losses Internal double enameled coating according to DIN 475 and a magnesium anode to provide optimum protection against corrosion Full compliance with WRAS Glass lined Omega Twin Coil Tank Models Tank Sizes EBS EBS OMICRON OMEGA Series Y Series BF Single Coil Twin Coil Single Coil Twin Coil Single Coil Calorifiers 100 Page Page Page 4-5 Page Page 4-5 Page Page 8-11 Page Page Page 8-11 Page Page 8-11 Page Page Page 8-11 Page Page Page 8-11 Page Page Page 8-11 Page Page Page 8-11 Page Page Page 8-11 Page Page Page 8-11 Page Page 18-19

4 Stainless Steel Tanks EBS Single Coil Tanks The EBS range of single coil mains fed un-vented tanks eliminate the need for cold water storage, and provide hot water at mains pressure to all outlets. Ranging from 100 to 00 litres capacity, the thermal transfer rate provided by the EBS tank out performs other hot water tanks due to the significantly larger surface area of the coils. The tanks can also be supplied for vented use. The high output coils are designed to complement Evinox boilers ensuring rapid recovery times and allowing the boiler to run in the condensing mode while producing hot water. The unit is equipped with a secondary return to allow the installation of a domestic hot water ring main, if required. Each module and integral coil is constructed from high grade 16L austenitic stainless steel. The prefabricated insulation provides very high standards of efficiency, with minimal heat loss. The EBS tank features a kw electrical immersion heater as standard. Options Unvented or vented models Optional tank stand for use in apartments to allow for simple installation of washing machine underneath L austenitic stainless steel tank 2 16 L austenitic stainless steel coil Expanded polystyrene insulation 4 ABS plastic casing 5 Domestic cold water inlet 6 Domestic hot water outlet 7 Primary circuit inlet Primary circuit outlet 9 Domestic water recycling circuit 10 Inspection trap 2 11 Thermometer 12 Water temperature setting aquastat 5

5 0 EBS-01-E A REAR VIEW TOP VIEW Models EBS EBS EBS EBS-1 00 Dimension A 795mm 1020mm 1245mm 1695mm Models EBS WRC number Tank water capacity litre Tank useful volume litre Primary capacity (internal exchanger volume) litre 4,1 4, 9,4 9,7 Exchanger surface dm² 78,5 81,7 177,5 184,6 Nominal exchanger power kw Exchanger load losses mce Continuous flow rate at 40 C l/min Load losses at continuous flow rate mce Primary flow rate l/h Maximum domestic hot water storage temperature C 80 Domestic hot water temperature safety thermostat C 90 Tank cooling constant according to EN 625 Wh/24h.l. C Static tank heat losses (maintenance consumption) kwh/24h Heat losses (tank at 65 C) W Max service pressure bar/mp 10/1 Thermostat preset C 20 to 80 Thermostat differential C 6 Ø Domestic cold water intake inch /4 /4 /4 /4 Ø Domestic hot water outlet inch /4 /4 /4 /4 Ø Primary inlet inch /4 /4 /4 /4 Ø Primary outlet inch /4 /4 /4 /4 Ø Recycling inch /4 /4 /4 /4 Ø Access flap mm 100 Ø Exchanger tube mm 25 x 1 Max electrical power with the immersion heater kit* W 000 Empty weight kg Packaged weight kg * The electrical power may be reduced to 2000 W or 1000 W if required. This should be done by the installer during electrical connection. Refer to the Immersion Heater Kit Manual for further information 5

6 EH VSsp RSsp EH 400 min. So T C AQUA-01-E T4 VSsp So T ww T E T2 A RHsp VHsp T2 VHsp F G KW/E Z WW Z H I Stainless Steel Tanks EBS Twin Coil Tanks The EBS range of twin coil, mains fed, un-vented stainless steel tanks are available in 200 or 00 litre models. The upper coil, within the twin coil tank, has been designed to be connected to a boiler whilst the lower coil is connected to an additional energy source, such as solar collectors. The extremely large coils provide a very high rate of thermal heat transfer, which ensures a low return temperature at the boiler as well as maximising the performance of the heating system. Each module and integral coil is constructed from high grade 16L austenitic stainless steel. The prefabricated insulation provides very high standards of efficiency, with minimal heat loss. The EBS tank features a kw electrical immersion heater as standard. A typical arrangement using the EBS twin coil tank would include Evi-Sol solar collectors, gas boiler, Evi-Sol Controls and Solar Pump Station to provide a system for heating and domestic hot water. Options Unvented or vented models J C B D D E EH KW WW VH SP VS SP RH SP RS SP Z T T 2 T T 4 So Drain Sleeve for electric resistance (0ption) Domestic cold water intake Hot water outlet Primary intake - (boiler to tank) (upper exchanger) Primary intake - (solar sensor to tank) (lower exchanger) Primary output - (tank to boiler) (upper exchanger) Primary outlet - (tank to solar sensor) (lower exchanger) Domestic hot water recycling Thermometer pocket Domestic hot water temperature sensor pocket - solar Domestic hot water temperature sensor pocket - heating (CTN) Pocket for a water overheating safety thermostat and for a domestic hot water temperature adjustment thermostat. Safety valve outlet EBS A 146mm 1796mm B 656mm 656mm C 100mm 100mm D 105mm 105mm E 76mm 961mm F 578mm 578mm G 65mm 77mm H 177mm 177mm I 77mm 110mm J 908mm 125mm ØVH SP /RH SP 1" 1" ØVS SP /RS SP 1" 1" ØKW/WW 1" 1" ØZ /4" /4" ØEH 1½" 1½" ØSo 22mm 22mm

7 Model SOLAR 200 SOLAR 00 WRC number Total water capacity litre Maximum storage temperature in boiler or solar mode C 80 Tank cooling constant (Cr) according to EN 625 Wh/24h.l. C 0,189 0,146 Maintenance consumption kwh/24h 1,705 1,99 Tank heat loss (ΔT 45K) W 71,1 82,8 Domestic hot water service pressure bar 6 Max boiler and solar exchanger service pressure bar 10 Empty weight (without packaging) kg 50 64,5 Packaged weight kg Upper exchanger - boiler side : Total capacity domestic hot water heated by the upper exchanger litre Primary capacity litre 5,2 5,2 Exchange surface dm 2 98,5 98,5 Exchanger power for: - t dep = 90 C and t ecs = 45 C kw 4,0 4,0 - t dep = 85 C and t ecs = 60 C kw 26,7 26,7 Continuous flow rate for : - t dep = 90 C and t ecs = 45 C l/h t dep = 85 C and t ecs = 60 C l/h Primary flow rate l/h Loss of exchanger load at max power mbar Lower exchanger - solar side : Total capacity domestic hot water heated by the lower exchanger litre Primary capacity litre 5,2 7,5 Exchange surface dm 2 98,5 141,7 Exchanger power for - t dep = 90 C and t ecs = 45 C kw 7,8 51,0 Primary flow rate l/h Loss of exchanger load at max power mbar 8 76 Electrical resistance : Electrical power max* W 000 Volume heated by electrical resistance litre Time for temperature to rise to 65 C hour 4,6 Electrical power supply / frequency 20 V - 50 Hz Intensity absorbed A 8,7 8,7 Protection index IP 44 t sto = Storage temperature t dep = Primary start temperature t aef = Cold water intake temperature (10 C) t ecs = Domestic hot water outlet temperature The heat loss stated concerns the tank alone without its connection pipes. You must insulate these thermally with care to maintain as little heat loss as possible on the heating system * The electrical power may be reduced to 2000 W or 1000 W if required. This should be done by the installer during electrical connection. Refer to the Immersion Heater Kit Manual for further information. Please refer to the technical installation manual for recovery times with different boiler combinations. This can be downloaded at 7

8 Glass Lined Tanks Series Omicron & Omicron Plus Single coil tanks The single coil Omicron range of storage tanks have been designed for domestic hot water (DHW) production. The tanks feature an internal double enamel coating according to DIN 475 and a magnesium anode to provide optimum protection against corrosion. The 500 litre tank features 50 mm PU hard foam insulation, and the 750 and 1000 litre models have 100 mm PU soft foam insulation, to minimise heat losses. The Omicron Plus is equipped with a solar control unit and solar pumping station pre-mounted on the tank. Larger models up to 5000 litres capacity are available. Please contact our technical department on for further information. Model shown is Omicron Plus

9 Omicron 500 Omicron 750 & AC AC AS 4 AS 1 1 FL AF RS FL AF RS 1 Sensor Ø 20* 2 Pumped DHW return 1" Thermometer Ø 20* 4 Electrical heating cartridge 1" 1 / 2 5 Safety limit thermostat 1/2 6 Magnesium anode 1" 1 / 2 RS Boiler return 1" AS Boiler flow 1" FL Flange for inspection Ø 180 AF Inlet cold water 1" AC Outlet hot water 1" D1 Diameter without insulation D2 Diameter with insulation - AF and AC connections are 1" for 500 litre tanks Connections are 1¼" for 750 and 1000 litre tanks * Blind tube is Ø20mm for 500 litre tank Connections are ½" for litre tanks Omicron Plus AC AF Tank Coil Model 1* 2* * 4* 5* RS* AS* FL* AF* AC* H H - Height with insulation 100 mm Ø D1 Ø D2 R - Tilting height without insulation R - Titling height with insulation temperature ( C) pressure (Bar) Coil m² Coil capacity (L) pressure (Bar) Weight (Kg) Soft foam insulation delivered separately * Dimension is measured from the centre of the connection to the base. Larger models are available up to 5000 Litres, please contact our technical team for information. Dimensions in mm 9

10 Feature Omicron 500 Omicron 750 Omicron 1000 Coil capacity Litres DHW consumption at 15 C - 40 C without boiler back-up Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Coil Immediate Withdrawal Storage Quantity/ litres temperature Withdrawal of hot domestic water 6 C Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Continuous withdrawal of DHW at 15 C - 45 C Water heater s power Flow kw DHW consumption temperature l/h Flow of primary circuit 80 C m /h Water heater s power Flow kw Coil DHW consumption temperature l/h Flow of primary circuit 70 C m /h Water heater s power Flow kw DHW consumption temperature l/h Flow of primary circuit 60 C m /h Pressure loss Lower Coil m Standby heat loss kwh/24h Note: Heat loss according to EN B Tank temperature: 65 C Room temperature: 20 C Temperature gradient: 45 C Omicron Plus Solar Control Panel Omicron Plus Solar Pump Station

11 Omicron Coil Pressure Loss.5 Pressure loss mh2o ,6 m 2 0,8 m 2 0,85 m 2 1,2 m 2 1,4 m 2 1,8 m 2 2,4 m 2 m Flow rate l/h Omicron Plus Solar Twin Pump Station Omicron Plus with Solar Twin Pump Station fitted 11

12 Glass Lined Tanks Series Omega / Omega Plus Twin coil solar cylinders The Omega range of twin coil, solar cylinders have been designed for domestic hot water (DHW) production in connection with traditional heating systems and solar installations. The tanks feature an internal double enamel coating according to DIN 475 and a magnesium anode to provide optimum protection against corrosion. The 500 litre tank features 50 mm direct injected PU hard foam CFC free insulation and the 750 and 1000 litre models have 100 mm PU soft foam CFC free insulation, to minimise heat losses. Insulation is delivered separately for 750 and 1000 litre models. The Omega Plus is equipped with a solar control unit and solar pumping station pre-mounted on the tank. Larger models up to 5000 litres capacity are available. Please contact our technical department on for further information. Model Shown is Omega Plus

13 Omega Omega 750 & AC AS2 RS2 5 AC AS AS1 4 RS2 AS1 1 1 FL AF RS1 FL AF RS1 1 Sensor Ø 20* 2 Pumped DHW return 1" Sensor Ø 20* 4 Electrical heating cartridge 1" 1 / 2 5 Safety limit thermostat 1/2 6 Magnesium anode 1" 1 / 2 RS1 Boiler return 1" AS1 Boiler flow 1" RS2 Boiler return 1" AS2 Boiler flow 1" FL Flange for inspection Ø 180 AF Inlet cold water 1" AC Outlet hot water 1" D1 Diameter without insulation D2 Diameter with insulation - AF and AC connections are 1" for 500 litre tanks Connections are 1¼" for 750 and 1000 litre tanks * Blind tube is Ø20mm for 500 litre tank Connections are ½ for litre tanks Omega Plus AC AF Tank Coils Model 1* 2* * 4* 5* RS1* AS1* RS2* AS2* FL* AF* AC* H H - Height with insulation 100 mm Ø D1 Ø D2 R - Tilting height without insulation R - Tilting height with insulation temperature ( C) pressure (Bar) Upper coil m² Upper coil capacity (L) Lower coil m² Lower coil capacity (L) pressure (Bar) Weight (Kg) Soft foam insulation delivered separately * Dimension is measured from the centre of the connection to the base. Larger models are available up to 5000 Litres, please contact our technical team for information. Dimensions in mm 1

14 Feature Unit of Measure Omega 500 Omega 750 Omega 1000 Capacity Upper coil Litres Capacity Lower coil Litres DHW consumption at 15 C - 40 C without boiler back-up Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Upper coil Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Immediate Withdrawal Storage Quantity/ litres temperature Withdrawal of hot domestic water 6 C Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Lower coil Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Withdrawal of hot domestic water Flow - l/m Consumption time Time/Min Immediate Withdrawal Quantity/ litres Continuous withdrawal of DHW at 15 C - 45 C Water heater s power flow kw DHW consumption temperature l/h Flow of primary circuit 80 C m /h Water heater s power flow kw Upper coil DHW consumption temperature l/h Flow of primary circuit 70 C m /h Water heater s power flow kw DHW consumption temperature l/h Flow of primary circuit 60 C m /h Water heater s power flow kw DHW consumption temperature l/h Flow of primary circuit 80 C m /h Water heater s power flow kw Lower coil DHW consumption temperature l/h Flow of primary circuit 70 C m /h Water heater s power flow kw DHW consumption temperature l/h Flow of primary circuit 60 C m /h Pressure loss Upper coil m Lower coil m Standby heat loss kwh/24h Note: Heat loss according to EN B Tank temperature: 65 C Room temperature: 20 C Temperature gradient: 45 C

15 Omega Coils Pressure Loss.5 Pressure loss mh2o ,6 m 2 0,8 m 2 0,85 m 2 1,2 m 2 1,4 m 2 1,8 m 2 2,4 m 2 m Flow rate l/h Omega Plus Solar Pump Station Omega Plus Solar Twin Pump Station 15

16 Series Y High performance tanks for systems including heat pumps and condensing boilers The series Y tank range has been designed for the production of domestic hot water for systems using heat pumps and condensing boilers. The tanks are suitable for applications where there is a large DHW demand. Due to the large heat exchange surface of the heating coil, high volumes of hot water can be produced, even with low primary flow temperature. The heating coil is constructed using an oval tube that increases the rate of flow and provides highly efficient heat transfer. Internally the tanks are protected from corrosion with an enamel coating, according to the DIN 475, and a magnesium anode. The Series Y tank features directly injected 50 mm, CFC free, polyurethane hard foam insulation, which minimises heat losses. Performance Data Feature Unit of Measure Series Y 500 Withdrawal of hot domestic water 15 C - 40 C without heating Withdrawal of hot domestic water l/m 15.6 Duration of flow Min Immediate Withdrawal litres 560 Withdrawal of hot domestic water l/m 5.0 Duration of flow Water heater temperature input 6 C Min Immediate Withdrawal litres 55 Withdrawal of hot domestic water l/m 54. Duration of flow Min Immediate Withdrawal litres 489 Continuous withdrawal of hot domestic water 15 C - 45 C Water heater power kw 101 Withdrawal of hot domestic water Input temperature 80 C l/h 2892 Flow of primary circuit m/h.8 Water heater power kw 91 Withdrawal of hot domestic water Input temperature 70 C l/h 2615 Flow of primary circuit m/h. Water heater power kw 54.5 Withdrawal of hot domestic water Input temperature 60 C l/h 1560 Flow of primary circuit m/h 4.0 Water heater power kw 7 Withdrawal of hot domestic water Input temperature 50 C l/h 106 Flow of primary circuit m/h 4.2 Pressure loss Coil m² 5.7

17 D2 AC AS RS AF FL 1 Sensor ½ 2 Thermometer ½ Vent for security valve 1 ½ 4 Electrical heating resistance 1 ½ 5 Safety limit thermostat ½ 6 Magnesium anode 1 ½ 7 Pumped DHW return 1 FL Flange for inspection Ø 180 RS Boiler inlet 1 AS Boiler outlet 1 AF Inlet cold water 1 AC Outlet hot water 1 Pressure loss coil mh2o Flow in L/h Tank Coils Model 1* 2* 4* 5* 7* AF* AC* FL* RS* AS* Ø D1 Ø D2 with insulation Tank Height Height with insulation 100 mm Tiliting height with insulation temperature ( C) pressure (Bar) Coil m² Coil capacity (L) pressure (Bar) Weight (Kg) * Dimension is measured from the centre of the connection to the base. Dimensions in mm 17

18 Series BF Calorifiers The multifunctional BF calorifier range provides domestic hot water (DHW) for traditional heating systems and solar installations. There are tank variants: F1 with a singleflange, F2 with two flanges and F with three flanges. The flanges enable the installation of heat exchangers such as finned copper exchanger or stainless steel bundle exchangers. The multifunctional cylinders are also suitable for connection with an external plate exchanger. In this situation the exchange surface can be exactly matched to the required power of different energy sources (gas, oil boilers, wood or wood pellet boilers and to solar collectors). The BF series is especially suitable for heating systems with large thermal power and large solar systems. The 1000 litre calorifier features an internal double glass enamel coating according to DIN 475; from 1500 litres the internal treatment is SINTERFLON coating. All tanks in the BF range are delivered with a magnesium anode for optimum protection against corrosion. The Series BF tank features CFC free, 100/125 mm, polyurethane soft foam insulation, which minimises heat losses. Copper Finned Tube Heat Exchangers Type m² L (mm) D (mm) A (mm) G * kw Single tube / Single tube / Single tube / Single tube /4 7.7 Double tube Double tube Double tube Double tube Single finned tube heat exchanger Performance in kw with the following conditions: Primary temperatures flow 80 C / return 70 C Double finned tube heat exchanger Secondary tank temperatures: Cold water supply 10 C / Hot water consumption 50 C

19 Single Tube Coil Area Of Coil Flow Rates (l/h) (m²) Pressure losses (m H2O) Pressure losses (m H2O) Pressure losses (m H2O) Pressure losses (m H2O) Double Tube Coil Area Of Coil Flow Rates (l/h) (m²) Pressure losses (m H2O) Pressure losses (m H2O) Pressure losses (m H2O) Pressure losses (m H2O) Ø D S FL 8 FL2 8 FL1 7 1 Free disposal 1 ½ 2 Free disposal 1 ½ Free disposal 1 ½ 4 Free disposal 1 ½ 5 Outlet hot water 1 6 Inlet cold water 1 7 Inlet cold water 1000 litre tank connection is 1 ¼ From 1500 litres the connection is 1 ½ 8 Connection for sensor ½ F1 With one flange F2 With two flanges F With flanges 9 Safety limit thermostat S Connection for sensor ½ FL1 Flange 00mm for heat exchanger 1 ½ FL2 Flange 00mm for heat exchanger 1 FL Flange 00mm for heat exchanger 1 D1 Diameter without insulation D2 Diameter with insulation Tank Model 1* 2* * 4* 7* S* F1* F2* F* H - Height Ø D1 Ø D2 with insulation Insulation Height with insulation100 mm Tiliting height without insulation pressure (Bar) temperature ( C) Treatment BF1 BF2 BF Soft Enamelling Soft Sinterflon Soft Sinterflon Soft Sinterflon Soft Sinterflon Soft Sinterflon Soft Sinterflon * Dimension is measured from the centre of the connection to the base. Dimensions in mm 19

20 Integrated heating intelligence Evinox Limited. Blenheim House. 1 Blenheim Road. Epsom. Surrey. KT19 9AP. T: +44 (0) E: info@evinox.co.uk technical@evinox.co.uk Evinox reserves the right to make changes and improvements which may necessitate alteration to the specification without prior notice. This is not a contractual document A

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating! ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating! Solar energy: free and inexhaustible. Energy and resources The solar age has begun. Low expenditure

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Solar Hot Water Heaters

Solar Hot Water Heaters Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS StainlessLite Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS Gledhill built on service, quality and tradition The Gledhill

More information

DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS

DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS DIETRISOL SOLAR WATER HEATING SYSTEMS NON-POLLUTING,

More information

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List VITOCELL-V 00 Indirect-fired domestic hot water storage tank 4 to 0 / 60 to Technical Data Manual Model Nos. and pricing: see Price List Vitocell-V 00 4 to / 60 to Vitocell-V 00 0 / Vitocell-V 00 CVA Series

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

MARCH 2007 EDITION WATER HEATERS GENERAL CATALOGUE

MARCH 2007 EDITION WATER HEATERS GENERAL CATALOGUE MARCH 2007 EDITION WATER HEATERS GENERAL CATALOGUE 1 Index 6_ LEGEND 42_ CYLINDERS 10_ ELECTRIC STORAGE WATER HEATERS SUPER GLASS R SUPER GLASS R SMALL TI TRONIC TI TRONIC SLIM TI TRONIC INDUSTRIAL TI

More information

SOLAR HEATING SYSTEMS. www.orkli.com

SOLAR HEATING SYSTEMS. www.orkli.com SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

STATIONARY WATER HEATERS

STATIONARY WATER HEATERS OPERATING AND INSTALLATION MANUAL STATIONARY WATER HEATERS OKCE 100 NTR / 2,2 kw OKCE 125 NTR / 2,2 kw OKCE 160 NTR / 2,2 kw OKCE 200 NTR / 2,2 kw OKCE 250 NTR / 2,2 kw OKCE 300 NTR / 2,2 kw OKCE 300 NTR

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

High-efficient gas boiler CompactGas

High-efficient gas boiler CompactGas High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard

More information

HEAT INTERFACE UNITS (Modular)

HEAT INTERFACE UNITS (Modular) HEAT INTERFACE UNITS The Rhico T Fire Modular is probably the most versatile HIU available, the basic unit is a indirect heating only module incorporating a circulation pump on the secondary circuit. (A

More information

Smile. The All-In-One Heating Controller

Smile. The All-In-One Heating Controller Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

Apartment and Communal Heating Solutions

Apartment and Communal Heating Solutions Apartment and Communal Heating Solutions Apartment and Communal Heating Due to the increasing requirements for more energy efficient buildings and changes to the Code for Sustainable Homes Legislation,

More information

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert. Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.com SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS

More information

Gas Condensing Boilers

Gas Condensing Boilers Gas Condensing Boilers www.johnsonandstarley.co.uk QuanTec Ultra Efficient Condensing Gas Boilers Including HR28C with Integral Passive Flue Gas Heat Recovery As market leaders and innovators, Johnson

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun American Solar Water Heating Systems The American solar thermal system is more than just a solar water heater - it s the

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

Commercial Gas Water Heater

Commercial Gas Water Heater Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate

More information

STORAGE CALORIFIERS & BUFFER VESSELS

STORAGE CALORIFIERS & BUFFER VESSELS STORAGE CAORIFIERS & BUFFER VESSES Page Contents Page Background Information Storage Volume & Recovery Time Primary Heat Source Materials of Construction Thermal Insulation Options System Considerations

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

YUTAKI S. Domestic Heating

YUTAKI S. Domestic Heating YUTAKI S ECOLOGY & COMFORT OUTDOOR UNIT RAS 3HVRNME-AF YUTAKI-S MODULE RWM 2~10.0HFSN3E The Yutaki S heat pump is the ideal solution both in new installations and refurbishments. Its exceptional performance

More information

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name. ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the

More information

Commercial Electric Water Heater

Commercial Electric Water Heater MODEL SE Commercial Electric Water Heater 6-120 Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages Features Heavy Duty Construction Hydrastone cement lining

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Solar Thermal Systems

Solar Thermal Systems Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann

More information

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International Presentation Overview Water Heater Piping Strategies How to size a water heater?

More information

Solar hot water systems that give energy efficiency a whole new meaning

Solar hot water systems that give energy efficiency a whole new meaning Solar hot water systems that give energy efficiency a whole new meaning The power to cut your energy bills for years to come When it comes to clean, cost effective energy solutions, the Leda Solar Hot

More information

Light Duty Commercial Electric Water Heater

Light Duty Commercial Electric Water Heater Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and

More information

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1 Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital

More information

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K The Die competent Kompetenzmarke brand for für energy Energiesparsysteme saving systems Conventional gas fired boilers open vented / sealed unvented CGU-2 / CGU-2K CGG-2 / CGG-2K NEW The next generation

More information

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as

More information

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction

More information

HOT WATER SYSTEMS. www.thermann.com.au

HOT WATER SYSTEMS. www.thermann.com.au HOT WTER SYSTEMS www.thermann.com.au GS HOT WTER SYSTEM The Thermann 4 star Gas hot water heater can suit almost any family type. With an adjustable thermostat for safety and efficiency it allows you to

More information

SF15K SF05KSS, SF10KSS

SF15K SF05KSS, SF10KSS Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water

More information

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency

More information

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME UNDERSTANDING HOT WATER SYSTEMS IN THE HOME This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

Kompressoren. Adsorption Dryer AD

Kompressoren. Adsorption Dryer AD Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated

More information

Create the right atmosphere with renewables.

Create the right atmosphere with renewables. The complete ROTEX heat pump product range Create the right atmosphere with renewables. ROTEX air-to-water and ground source heat pumps for new build and modernisation. The inexhaustible heat source on

More information

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

SOLAR HOT WATER SOLUTIONS stainless steel roof systems SOLAR HOT WATER SOLUTIONS stainless steel roof systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a

More information

VIESMANN. VITODENS Gas condensing boiler 1.9 to 35.0 kw. Technical guide. VITODENS 200-W Type B2HA, B2KA. VITODENS 222-W Type B2LA

VIESMANN. VITODENS Gas condensing boiler 1.9 to 35.0 kw. Technical guide. VITODENS 200-W Type B2HA, B2KA. VITODENS 222-W Type B2LA VIESMANN VITODENS Gas condensing boiler 1.9 to 35.0 kw Technical guide VITODENS 200-W Type B2HA, B2KA Wall mounted gas condensing boiler 3.2 to 35.0 kw For natural gas and LPG VITODENS 222-W Type B2LA

More information

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water modules:

More information

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

www.garrisonwaterheaters.com Electric & Gas Water Heaters

www.garrisonwaterheaters.com Electric & Gas Water Heaters www.garrisonwaterheaters.com Electric & Gas Water Heaters Hot Water: Take it for Granted with Garrison According to the U.S. Department of Energy, the average American home uses 64 gallons of hot water

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio Valves, controls + systems Innovation + Quality Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio ErP made easy! ErP Directive Content ErP Directive

More information

Solar Collector Series. Product List

Solar Collector Series. Product List Solar Collector Series List FULL COLLECTORS (MANIFOLD, TUBES & ROOF FRAME) : CSR00051 Apricus Collector : AP10 10-Way Manifold, 10 Tubes and Standard Roof Frame CSR00052 Apricus Collector : AP20 20-Way

More information

maximise the sun s energy with warmflow solar Warmflow Solar

maximise the sun s energy with warmflow solar Warmflow Solar maximise the sun s energy with warmflow solar Warmflow Solar Warmflow Solar warmflow solar - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we

More information

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB

CALEFFI. SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production. SATK20 - SATK30 series 01209/13 GB SATK wall-mounted Heat Interface Unit - HIU Instantaneous domestic hot water production SATK20 - SATK30 series ACCREDITED CALEFFI 01209/13 GB ISO 9001 FM 21654 ISO 9001 No. 0003 The latest generation heat

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk

Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

DESIGN, DEVELOPMENT AND EUROPEAN MANUFACTURING ECO DOMESTIC HOT WATER ECONOMY COMFORT ECOLOGY UP TO 85% ECONOMY. New Design

DESIGN, DEVELOPMENT AND EUROPEAN MANUFACTURING ECO DOMESTIC HOT WATER ECONOMY COMFORT ECOLOGY UP TO 85% ECONOMY. New Design DESIGN, DEVELOPMENT AND EUROPEAN MANUFACTURING ECO DOMESTIC HOT WATER ECONOMY COMFORT ECOLOGY PROBABLY THE MOST ADVANCED SOLAR WATER HEATER IN THE WORLD HOT WATER 4 HOURS A DAY WORK DAY AND NIGHT, RAIN

More information

SunMor SM-V30 Solar Water Heater Installation Manual

SunMor SM-V30 Solar Water Heater Installation Manual SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2

WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2 HAC_C0.qxd 7/4/08 9: Page 74 Chapter Pipe sizing Pipes and fittings should be sized so that the flow rates for individual draw-offs are equal to the design flow rates shown in table.. During simultaneous

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Thermo Siphon Solar Systems

Thermo Siphon Solar Systems Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter

More information

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling

Stove-boiler for solid fuels 12-30 KW Directions for use and assembling Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min. www.kaeser.com

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min. www.kaeser.com Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min www.kaeser.com Made in Germany KAESER s renowned MOBILAIR range of portable compressors is

More information

Versati Air to Water Heat Pump

Versati Air to Water Heat Pump Versati Air to Water Heat Pump VERSATI DC Inverter Multifunctional Air To Water Heat Pump Nowadays, people are increasingly focusing on heating costs as well as environmental issues. Traditional heating

More information

Heat Recovery based on Exhaust Air

Heat Recovery based on Exhaust Air Heat Recovery based on Exhaust Air Heating Domestic Hot Water Controlled Ventilation Preheated Supply Air MADE IN SWEDEN VENTILATION HEALTH ASPECTS Ventilation, which means totally hygienic inside air,

More information

Master & Amplifier For ModuSat Communal Heating

Master & Amplifier For ModuSat Communal Heating Master The ModuSat master controller provides a convenient central point for connection of all ModuSat HIU S on a communal heating scheme. The ModuSat s and master are linked via a hard wired Modbus RS485

More information

Professional Report. Map section. Location of the system. Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m

Professional Report. Map section. Location of the system. Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m Puulämmitys 6 x SF3 Location of the system Map section Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m This report has been created by: Samppa Takala Samppa Takala Nyrhintie 14 28760 Pori

More information

VIESMANN. VITODENS Gas condensing boiler 3.8 to 35.0 kw. Technical guide. VITODENS 200-W Type WB2C. VITODENS 222-W Type WS2B. VITODENS 300-W Type WB3D

VIESMANN. VITODENS Gas condensing boiler 3.8 to 35.0 kw. Technical guide. VITODENS 200-W Type WB2C. VITODENS 222-W Type WS2B. VITODENS 300-W Type WB3D VIESMNN VITODENS Gas condensing boiler 3.8 to 35.0 kw Technical guide VITODENS 200-W Type WB2C Wall mounted gas condensing boiler, 4.8 to 35.0 kw, for natural gas and LPG VITODENS 222-W Type WS2B Compact

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information