A Model Study of Micropile Group Efficiency under Axial Loading Condition

Size: px
Start display at page:

Download "A Model Study of Micropile Group Efficiency under Axial Loading Condition"

Transcription

1 International Journal of Civil Engineering Research. ISSN Volume 5, Number 4 (2014), pp Research India Publications A Model Study of Micropile Group Efficiency under Axial Loading Condition Nihar Gogoi 1, Sanandam Bordoloi 2 and Binu Sharma 3 1, 2, 3 Civil Engineering Department, Assam Engineering College, Jalukbari, Guwahati, India. Abstract The application of micropiles in retrofitting or as structural support is a technically viable and economically feasible solution in many situations. Micropiles are especially useful in places where heavy machinery cannot gain access in order to lay down conventional piles. As suggested by their name, micropiles have a smaller diameter than conventional pile. These piles comprise of a central steel reinforcement surrounded by grout that fastens the pile with the soil. Owing to its wide application, it is logical to study the interaction between the soil and micropiles under various loading conditions. This paper deals with the investigation of a model experimental study of group micropiles of different length to diameter ratio as well as different spacing between the piles in the group. The piles were installed in sand bed of 50% relative density and subjected to axial loading condition. Ratio of length to diameter has been found to be a major factor that influences ultimate axial resistance of the group. Group efficiencies of micropiles groups were determined at length to diameter ratio varying from 30 to 70 and at 2D, 4D and 6D spacing between the piles. Keywords: Micropiles, pile group efficiency. 1. Introduction Micropiles are piles with a smaller diameter (generally ranging from piles of about 100mm to 250 mm) than conventional piles. These piles comprise of a central steel reinforcement surrounded by grout that fastens the pile with the soil. The grout is interjected under a pressure ranging from 0.8Mpa to 1Mpa. The high pressure grouting causes the fluid part of the cement mix to penetrate into the interstices of the

2 324 Sanandam Bordoloi et al surrounding soil; thereby creating a transition zone comprising of grout mixed soil between the body of the micropile and the soil, resulting in a strong grout-ground bond. The introduction of micropiles occurred in Italy in the year 1950 as a means for underpin old historic buildings and monuments. Micropiles have been gradually gaining popularity around the world since the late 1980 s when the method gained acceptance as a mean to underpin the existing structures. Micropiles exhibit high skin friction, as a result of which the load carrying capacity of micropiles is higher than that anticipated by the conventional bearing capacity theory. Its quick response to the slightest movement of the structure is one of its most notable features. Even when the load reaches crushing strength of concrete they display settlement of only a few mm. Micropile systems are also known to demonstrate flexibility under dynamic loading. Another distinguished feature of micropile is that retrofitting methods that employ micropiles can be applied to liquefied ground. Furthermore, its small boring diameter allows its construction almost at any ground condition and with equipment smaller than that required for a conventional pile. In this investigation a model experimental study has been undertaken on micropiles. Single piles having different length to diameter ratio, and grouped piles having different length to diameter as well as different centre-to-centre spacing were installed in a sand bed having a 50% relative density. The piles and pile groups were subjected to downward vertical axial load. Subsequently their ultimate bearing capacities were determined and the load-settlement curves were plotted in order to determine their group efficiency. 2. Experimental Setup 2.1. Properties of sand The micropiles of different L/D ratio were installed in sand placed inside a model tank of size (1.7m x 1.5m x 0.93m). The coefficient of curvature and uniformity coefficient of the sand were found out to be 0.98 and 2.08 respectively. The effective grain size of the sand was determined as 0.22mm. The minimum void ratio and maximum void ratio were ascertained as 0.68 and 0.88 respectively. The specific gravity of the sand was found out to be Since the tank used for the experiment was to be filled with uniform density, rainfall technique was adopted. Sand was poured uniformly through a strainer from a constant height of 60cm from the surface of the sand bed. The corresponding relative density obtained in the sand was 50%. For sand with relative density of 50%, density and angle of internal friction (ɸ) was found to be 1.5 gm/cc and 38 o respectively Installation of the micropiles Micropiles were installed as single piles of L/D ratios of 30, 50 and 70, and as square groups of 4 piles per group with spacing of 2D, 4D and 6D with L/D ratios of 30, 50 and 70 for each of the spacing conditions. Steel pipes of external diameter 1.2cm and internal diameter 1.0cm were used for casting the piles. At the lower end of the pile a conical wooden shoe was attached. A 2mm diameter mild steel rod was fixed to the

3 A Model Study of Micropile Group Efficiency under Axial Loading Condition 325 wooden shoe and inserted into the pipe as reinforcement. Keeping the steel pipe perfectly vertical, it was driven into the sand manually along with the steel reinforcement and the wooden shoe. The piles were then grouted with cement slurry of water cement ratio 0.6 under a constant gravity head of 100cm. Pile caps were constructed using wooden framework and were reinforced with steel wire mesh Measurement of load and deflection Application of load was carried out using a mechanical jack system where the jack was fixed such that it could slide when required. The proving ring with a constant of 0.99 kg per division (Figure 2) was fixed to the top of the pile cap by ball and socket arrangement. Load tests were carried out four days after grouting. Load-deflection test was done according to the norms of IS 2911 (Pt-4) 1985 code of practice for load test on group piles. Load was measured by means of the proving ring and displacement was measured by a dial gauge fixed to the pile cap. 3. Test Results 3.1. Single micropiles Individual micropiles were cast with L/D ratios of 30, 50 and 70. On the load versus displacement curve (Figure 3), the point at which the curves reach their peak values from which the pile load reduces with further displacement is taken as the ultimate load capacity of the micropile. Figure 4 shows the plot of ultimate axial load resistance versus L/D ratio. It is observed from the plot that the ultimate axial resistance gradually increase from L/D 30 to L/D 70. Fig. 1: Load versus settlement plot for single pile at L/D= 30, 50, 70.

4 326 Sanandam Bordoloi et al Fig. 2: Ultimate load versus L/D ratio for single pile Micropile Groups Micropiles groups of the same L/D ratio as that of the single piles were cast. The pile groups consisted of 4 piles at spacing of 2D, 4D and 6D. Because of space limitations, only the variations in axial pile capacity with the pile head displacement for pile group 4D are shown in Figure 5. Figure 5 clearly shows that the load gradually increases with increase in displacement until the load displacement curves reach their peak values from which the pile load reduces with further continuous displacement. Thus, the ultimate load capacities of the pile groups were determined. It can be seen in Figure 5 that the ultimate load capacity increases with the increase in L/D ratio. Further, with increase in L/D ratio of the pile groups exhibit a decrease in the settlement before failure. Fig. 3: Load versus settlement plot for pile groups at 4D spacing.

5 A Model Study of Micropile Group Efficiency under Axial Loading Condition 327 Fig. 4: Load Vs L/D ratio for 2D spacing. Fig. 5: Load Vs L/D ratio for 4D spacing. Fig. 6: Load Vs L/D ratio for 6D spacing.

6 328 Sanandam Bordoloi et al Figure 6, 7 and 8 show the variation of ultimate axial load with length to diameter ratio of the micropile groups at the three different spacing. It is seen that all the three plots show an almost identical trend. L/D ratio of the micropile groups could not be increased due to the limited tank depth of 0.93 m. 4. Group Efficiency There has been quite a lot of research regarding the group efficiency of micropiles. However, the results have not been in agreement and a reasonable explanation has not yet been arrived at. In the study of piles under vertical loading, a parameter termed as efficiency is often used to evaluate the group effect: η = (1) where η= efficiency of the pile group; Q g = axial capacity of pile group; Q s = axial capacity of single pile; and n = number of pile group. The group efficiencies of the pile groups at 2D, 4D, and 6D spacing had been determined. Table 1 shows the group efficiency of the various pile groups that we studies in our experiment. Table 1: Group efficiency table for different L/D ratio and spacing. Length(cm) L/D ratio Q u (N) Ultimate Load (N) Group Efficiency 2D 4D 6D 2D 4D 6D Fig. 7: Group efficiency (η) versus Spacing/Diameter ratio

7 A Model Study of Micropile Group Efficiency under Axial Loading Condition 329 Group efficiency versus spacing/diameter ratio is shown in Figure 11. The observation shows that the group efficiency increases when the spacing increases from 2D to 4D. However, when the spacing is further increased to 6D, the group efficiency shows a very insignificant change. Thus, maximum group efficiency is observed when the spacing in 4D and the maximum value increases with increase in L/D ratio. The results also show that positive group effect is only observed in the piles groups with L/D ratio 50 and 70 at 4D and 6D spacing. 5. Comparision with Previous Literature Lizzi (1985) reported model test results of group efficiency of micropiles on coarse sand. The experimental consisted of four series of tests, with piles length of 50, 100, 150, and 200 pile diameters, respectively. Each series consisted of 6 groups of 3 piles each, spaced at 2 to 7 diameters, plus additional single piles. The results of the tests are as summarized in the Figure 13. The result showed positive group effect at spacing ranging from 2 to 6 times the pile diameter. Fig. 8: Efficiency Vs Spacing (Lizzi 1985). Comparing the result of the present experiment with that of Lizzi, it was observed that both results show a similar trend for pile groups with L/D ratio of 50 and 70. A positive group effect was observed in all of the piles groups of lengths 50D to 200D studies by Lizzi, while the present experiment show positive group effect in pile groups with length 50D and 70D, and not for 30D. Nonetheless, an increase in the group efficiency from 2D to 4D spacing, similar to the Lizzi s results, has been invariably observed in all the piles groups. Again, it is seen that Lizzi s result shows an increase in the maximum efficiency with increase in depth, similar to the findings of the current experiment.

8 330 Sanandam Bordoloi et al Furthermore, O neill s (1983) study on group of 4 piles conducted on medium dense to dense sand (relative density 50% to 90%) also shows that there is an increase in group efficiency from 2D to 4D spacing and very little decrease thereafter. It can be seen in Figure 14 that the curve is quite similar to the one deduced by the current experiment. Fig. 9: Group efficiencies from test model pile groups in cohesionless soil subjected to vertical loads reported by O neill (1983), Lizzie (1978) and Cambefort (1953) Based on the comparisons, it is seen that there is inconsistency of results of the various researcher workers. However, it is observed that for micropile groups of four, maximum group efficiency is observed when the spacing between the piles is 4D. Most of the curves (group efficiency versus spacing) have shown a similar trend of increase followed by a gradual decrease. 6. Conclusions Based on the results of the present experimental investigation, some conclusions are drawn with respect to ultimate load capacity of micropiles and micropile groups. Ultimate load capacity increased with the increase in length to diameter ratio but the increase was not linear. Furthermore, the settlement before reaching the ultimate load capacity decreased with the increase in length to diameter ratio. A few conclusions were also drawn regarding group efficiency of micropiles. The efficiency increased with increase in spacing between piles in a group up to 4D then slightly decreases with the increase in spacing. It was seen that the maximum efficiency occurs when the spacing between piles is 4D. The maximum efficiency is dependent on L/D ratio and increases with the increase with L/D ratio.

9 A Model Study of Micropile Group Efficiency under Axial Loading Condition 331 Further comprehensive experimental work, covering a broad range of pile characteristics and soil properties, is needed to get definitive conclusions about the effects of spacing on efficiency of pile groups. References [1] Lizzi, F., The Reticolo Di PALI RADICE (Reticulated Root pile) for the improvement of soil resistance physical aspects and design approaches-viii ECSMFE, Helsinki, 1983, pp [2] Sabini, G. and Sapio, G, Behaviour of small diameter piles under axial load, X ICSMFE, Vol.-2, 1981, pp [3] O Neil, M.W. and Pierry, R.F., Behaviour of mini-grouted piles used in foundation underpinning in Beaumont Clay, Houston, Texas, U.S.A. Proceeding of the International Conference piling and deep foundation London/15, 1 May 1989, pp [4] Benslimane, A., Juran, I., Hanna, S. and Drabkin, S., Seismic Behaviour of Micropile System. Proceedings of sessions of Geo-congress 98, October 18-21, 1998, Boston, Massachusetts. [5] Deshmukh, A.M. and Ganpule, V.T.,Design and Construction of mini grouted piles in Bombay region. Pile talk international, July 1990: Jakarta, Indonesia, pp [6] Balasingham Muhunthan, Shanji Shu, and Adrian Rodriguez Marek, Sand State and Performance Analysis of Micropiles, FHWA, June 2006, pp

10 332 Sanandam Bordoloi et al

Interference Effect of Two Nearby Strip Footings. on Reinforced Sand

Interference Effect of Two Nearby Strip Footings. on Reinforced Sand Contemporary Engineering Sciences, Vol. 2, 2009, no. 12, 577-592 Interference Effect of Two Nearby Strip Footings on Reinforced Sand Priyanka Ghosh Assistant Professor, Dept. of Civil Engineering, IIT

More information

Vertical Capacity The program evaluates the uplift and compression capacity of the pile.

Vertical Capacity The program evaluates the uplift and compression capacity of the pile. AllPile Software is a Windows-based analysis program that handles virtually all types of piles, including steel pipes, H-piles, pre-cast concrete piles, auger-cast piles, drilled shafts, timber piles,

More information

EFFECT OF PILE LOAD TESTING SETUP ON THE ACCURACY OF THE RESULTS ABSTRACT

EFFECT OF PILE LOAD TESTING SETUP ON THE ACCURACY OF THE RESULTS ABSTRACT EFFECT OF PILE LOAD TESTING SETUP ON THE ACCURACY OF THE RESULTS HOSSAM E.A. ALI 1 AND AHMED H. ABDEL-RAHMAN 2 ABSTRACT It is a common practice to axially load piles in order to test their load-settlement

More information

The Experimental Study on Uplift Bearing Capacity of Helical Piles in Silt Deposits

The Experimental Study on Uplift Bearing Capacity of Helical Piles in Silt Deposits The Experimental Study on Uplift Bearing Capacity of Helical Piles in Silt Deposits Likhitha.H 1, B.R Ramesh 2 PG student, Department of Geotechnical Engineering, East West Institute of Technology, Bangalore,

More information

Behaviour of Long Pile in Slope Subjected to Inclined Load

Behaviour of Long Pile in Slope Subjected to Inclined Load Behaviour of Long Pile in Slope Subjected to Inclined Load Dr. A. I. Dhatrak 1, Gaurav Bhagat 2 Associate Professor, Department of Civil Engg., Government College of Engineering, Amravati, Maharashtra,

More information

Pullout Capacity of Model Piles in Sand

Pullout Capacity of Model Piles in Sand INDIAN GEOTECHNICAL SOCIETY CHENNAI CHAPTER Pullout Capacity of Model Piles in Sand K. Kimi Bose 1 and A. Krishnan 2 ABSTRACT: A large scale experimental program using vertical and batter model piles in

More information

EXPERIMENTAL EVALUATION OF REINFORCED CONCRETE BEAM RETROFITTED WITH FERROCEMENT

EXPERIMENTAL EVALUATION OF REINFORCED CONCRETE BEAM RETROFITTED WITH FERROCEMENT Int. J. Struct. & Civil Engg. Res. 2013 Y V Ladi and P M Mohite, 2013 Research Paper EXPERIMENTAL EVALUATION OF REINFORCED CONCRETE BEAM RETROFITTED WITH FERROCEMENT Y V Ladi 1 * and P M Mohite 2 *Corresponding

More information

Chapter 18 Pile Foundations

Chapter 18 Pile Foundations Page 18 1 1. Piles are structural members made of (a) steel. (b) concrete. (c) timber. Chapter 18 Pile Foundations 2. Which of the following foundations will have the highest cost? (a) Pile foundation

More information

Paper - 4 - The relation of Micropile Diameters in case of Pressure casting and non-pressure casting (30)

Paper - 4 - The relation of Micropile Diameters in case of Pressure casting and non-pressure casting (30) Paper - 4 - Elarabi, H.; Abbas A., The relation of Micropile Diameters in case of Pressure casting and non-pressure casting,magnt Research Report (ISSN. 1444-8939), Vol.2 (2) Accepted for publication The

More information

Continuous Flight Auger Pile Bridge Foundations (Phase II)

Continuous Flight Auger Pile Bridge Foundations (Phase II) Continuous Flight Auger Pile Bridge Foundations (Phase II) Project No. 5-3940-03 Implementation Report 5-3940-03-1 Texas Department of Transportation by C. Vipulanandan Ph.D., P.E. O. Guvener K. Vembu

More information

HIGH CAPACITY HELICAL PILES A NEW DIMENSION FOR BRIDGE FOUNDATIONS

HIGH CAPACITY HELICAL PILES A NEW DIMENSION FOR BRIDGE FOUNDATIONS Proceedings of 8 th International Conference on Short and Medium Span Bridges Niagara Falls, Canada 2010 HIGH CAPACITY HELICAL PILES A NEW DIMENSION FOR BRIDGE FOUNDATIONS Mohammed Sakr Almita Manufacturing

More information

ODOT LRFD Foundations

ODOT LRFD Foundations Ohio Department of Transportation John R. Kasich, Governor Jerry Wray, Director ODOT LRFD Foundations Alexander Dettloff, P.E. Foundation Engineer Office of Geotechnical Engineering May 07, 2013 AASHTO

More information

Eccentrically Loaded Small Scale Ring Footing on Resting on Cohesionless Soil

Eccentrically Loaded Small Scale Ring Footing on Resting on Cohesionless Soil RESEARCH ARTICLE OPEN ACCESS Eccentrically Loaded Small Scale Ring Footing on Resting on Cohesionless Soil Dr. A. I. Dhatrak 1, Poonam Gawande 2 1 Associate Professor, Department of Civil Engineering,

More information

PERFORMANCE OF BAMBOO REINFORCED CONCRETE BEAM

PERFORMANCE OF BAMBOO REINFORCED CONCRETE BEAM International Journal of Science, Environment and Technology, Vol. 3, No 3, 2014, 836 840 ISSN 2278-3687 (O) PERFORMANCE OF BAMBOO REINFORCED CONCRETE BEAM I.K. Khan Department of Civil Engineering, Aligarh

More information

minijet : A New Type of Micropile

minijet : A New Type of Micropile minijet : A New Type of Micropile Dr. Donald A. Bruce 1, Jeffrey J. Bean 2, and Timothy J. Myers 3 1.0 BACKGROUND In U.S. practice (Reference 1), it is common to classify micropiles on the basis of their

More information

The Results of Dynamic (Pile Driving Analysis) and Traditional Static Piling Tests in Capital of Kazakhstan

The Results of Dynamic (Pile Driving Analysis) and Traditional Static Piling Tests in Capital of Kazakhstan Historical Experience and Challenges of Proceedings of 13th Baltic Sea Geotechnical Conference Geotechnical Problems in Baltic Sea Region ISSN 2424-5968 / ISBN 978-609-457-957-8 Lithuanian Geotechnical

More information

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus Vol.3, Issue.1, Jan-Feb. 2013 pp-284-290 ISSN: 2249-6645 Measurement of Soil Parameters by Using Penetrometer Needle Apparatus Mahmoud M. Abu zeid, 1 Amr M. Radwan, 2 Emad A. Osman, 3 Ahmed M.Abu-bakr,

More information

Anchor Fitted with Special Fin for Soil Reinforcement

Anchor Fitted with Special Fin for Soil Reinforcement MAT EC Web of Conferences 17, 010 13 (2014) DOI: 10.1051/ matecconf/ 20141701013 C Owned by the authors, published by EDP Sciences, 2014 Anchor Fitted with Special Fin for Soil Reinforcement A.N. Abdul

More information

8.5 Structural arrangement of foundation

8.5 Structural arrangement of foundation 8.5 Structural arrangement of foundation Based on structural arrangement of foundations, the various type of foundations are possible. The necessity of erecting towers on a variety of soils has made it

More information

ENGINEERING SPECIFICATION PILE LOAD TEST

ENGINEERING SPECIFICATION PILE LOAD TEST Sheet 1 of 14 ENGINEERING SPECIFICATION PILE LOAD TEST FOR CIVIL WORKS FOR HINDUSTAN PETROLEUM CORPORATION LTD. VISAKH REFINERY DHT PROJECT TEIL JOB NO. : 6261 DOCUMENT NO. : C - 001 A 29.12.2008 For Bid

More information

DRIVEN PIPE PILES IN DENSE SAND

DRIVEN PIPE PILES IN DENSE SAND DRIVEN PIPE PILES IN DENSE SAND BYRON BYRNE GEOMECHANICS GROUP THE UNIVERSITY OF WESTERN AUSTRALIA ABSTRACT: Piles are often driven open ended into dense sand with the aim of increasing the ease of penetration

More information

LABORATORY CONSOLIDATION TEST

LABORATORY CONSOLIDATION TEST 1 LABORATORY CONSOLIDATION TEST Application Settlement problems are actually two problems in one. Both the magnitude of settlement and time rate at which this process occurs must be estimated on the basis

More information

THE EFFECT OF IMPROVEMENT SURROUNDING SOIL ON BORED PILE FRICTION CAPACITY

THE EFFECT OF IMPROVEMENT SURROUNDING SOIL ON BORED PILE FRICTION CAPACITY International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 1, Jan-Feb 2016, pp. 260-273, Article ID: IJCIET_07_01_022 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=1

More information

Experimental Study on Flexural Behavior of Reinforced Concrete Beams by Replacing Copper Slag as Fine Aggregate

Experimental Study on Flexural Behavior of Reinforced Concrete Beams by Replacing Copper Slag as Fine Aggregate International Journal of Civil and Structural Engineering Research ISSN 2348-77 (Online) Experimental Study on Flexural Behavior of Reinforced Concrete Beams by Replacing Copper Slag as Fine Aggregate

More information

International Society for Helical Foundations (ISHF)

International Society for Helical Foundations (ISHF) QUICK DESIGN GUIDE For Screw-Piles and Helical Anchors in Soils Ver. 1.0 Prepared by Dr. Alan J. Lutenegger, P.E., F. ASCE for International Society for Helical Foundations (ISHF) Copyright 2015 (ISHF)

More information

GABION RETAINING WALLS WITH ALTERNATE FILL MATERIALS

GABION RETAINING WALLS WITH ALTERNATE FILL MATERIALS IGC 2009, Guntur, INDIA GABION RETAINING WALLS WITH ALTERNATE FILL MATERIALS K.S. Beena Reader, School of Engineering, Cochin University of Science and Technology, Cochin 682022, India. E-mail: beenavg@cusat.ac.in

More information

DRILLED DEEP FOUNDATIONS

DRILLED DEEP FOUNDATIONS GROUPS: ADVANTAGES Figure 14-2. Group vs. Single Shaft (FHWA NHI-10-016). Large overturning moments are most effectively resisted using groups of shafts. Higher axial capacities. May be cost effective

More information

Large and deep cast-in-place reinforced concrete piles using of shaft grout

Large and deep cast-in-place reinforced concrete piles using of shaft grout IABSE-JSCE Joint Conference on Advances in Bridge Engineering-II, August 8-10, 2010, Dhaka, Bangladesh. ISBN: 978-984-33-1893-0 Amin, Okui, Bhuiyan (eds.) www.iabse-bd.org Large and deep cast-in-place

More information

On the Subject of Piles in Tension. M. England BSc., MSc., DIC. PhD

On the Subject of Piles in Tension. M. England BSc., MSc., DIC. PhD 680 On the Subject of Piles in Tension M. England BSc., MSc., DIC. PhD Fugro Loadtest Ltd., 14 Scotts Avenue, Sunbury on Thames, Middlesex, TW16 7HZ, UK. ABSTRACT Some of the difficulties

More information

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department

More information

DYNAMIC PILE MONITORING FOR OFFSHORE PILE ACCEPTANCE

DYNAMIC PILE MONITORING FOR OFFSHORE PILE ACCEPTANCE DYNAMIC PILE MONITORING FOR OFFSHORE PILE ACCEPTANCE Scott Webster and Robin Givet, GRL Engineers, Inc., Charlotte, NC, USA Dynamic pile Monitoring Services (DMS) have been used for testing of offshore

More information

Analysis of Reinforced Concrete Coupled Shear Wall Using Finite Element Method

Analysis of Reinforced Concrete Coupled Shear Wall Using Finite Element Method ISSN : 2348-0033 (Online ISSN : 2249-4944 (Print Analysis of Reinforced Concrete Coupled Shear Wall Using Finite Element Method Gummadi Amar Assistant Professor, Dhanekula Institute of Engineering & Technology,

More information

Module 5 : Design of Deep Foundations Lecture 22 : Ultimate pile capacity [ Section 22.1 : Procedure for ultimate pile capacity : Static analysis ]

Module 5 : Design of Deep Foundations Lecture 22 : Ultimate pile capacity [ Section 22.1 : Procedure for ultimate pile capacity : Static analysis ] Lecture 22 : Ultimate pile capacity [ Section 22.1 : Procedure for ultimate pile capacity : Static analysis ] Objectives In this section you will learn the following Static analysis Piles in granular soils

More information

Performance Evaluation of Bamboo Reinforced Concrete Beam

Performance Evaluation of Bamboo Reinforced Concrete Beam Compressive (MPa) Setting Time Fineness International Journal of Engineering & Technology IJET-IJENS Vol: 11 No: 04 113 Performance Evaluation of Bamboo Reinforced Concrete Beam M. M. Rahman, M. H. Rashid,

More information

MICROPILE SPECIFICATION

MICROPILE SPECIFICATION MICROPILE SPECIFICATION 1.0 GENERAL The Contractor shall supply, install and test micropiles shown on the drawings or specified herein in accordance with the specification The Contractor shall allow for

More information

Group effects of piles due to lateral soil movement

Group effects of piles due to lateral soil movement University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers Faculty of Engineering and Information Sciences 2013 Group effects of piles due to lateral soil movement

More information

DRILLED DEEP FOUNDATIONS

DRILLED DEEP FOUNDATIONS 14.528 DRILLED DEEP FOUNDATIONS MICROPILES: HISTORY Early 1950 s in Italy Conceived to underpin historic structures and monuments damaged in WW II. 1952 - Palo Radice (Root Pile) patented by Fondedile

More information

CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

CEEN 162 - Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests PURPOSE: The parameters of the shear strength relationship provide a means of evaluating the load carrying capacity of soils, stability of slopes, and pile capacity. The direct shear test is one of the

More information

Comparison of Static and Dynamic Load Test of Pile

Comparison of Static and Dynamic Load Test of Pile Comparison of Static and Dynamic Load Test of Pile C. Rajagopal Post Graduate Student Applied Mechanics Department., S. V. National Institute of Technology, Surat-397, India rajapreethigopal@rediffmail.com

More information

Micropiles an Introduction

Micropiles an Introduction Micropiles an Introduction GeoProfound Engineering Sdn Bhd Micropiles - Timeline 1952 - First introduced in Italy for foundation restoration (underpinning) of WWII damaged buildings 1960 s Widely used

More information

AXIAL LOAD TEST PROCEDURES FOR PILE FOUNDATIONS

AXIAL LOAD TEST PROCEDURES FOR PILE FOUNDATIONS AXIAL LOAD TEST PROCEDURES FOR PILE FOUNDATIONS INTRODUCTION Because of the non-availability of reliable procedures for assessing the load transfer mechanisms between piles and surrounding soil, or for

More information

Prestressed Concrete Piles

Prestressed Concrete Piles FOUNDATION ALTERNATIVES TO MITIGATE EARTHQUAKE EFFECTS 13.17 FIGURE 13.11 Excavation for the grade beam that will span between the two piers. Usually this foundation system is designed by the structural

More information

Comprehensive Design Example 2: Foundations for Bulk Storage Facility

Comprehensive Design Example 2: Foundations for Bulk Storage Facility Comprehensive Design Example 2: Foundations for Bulk Storage Facility Problem The project consists of building several dry product storage silos near an existing rail siding in an open field presently

More information

Presented by: Keller Ground Engineering India Pvt. Ltd., India. 2 Cenotaph Court, No. 28 Cenotaph Road, Taynampet Chennai India

Presented by: Keller Ground Engineering India Pvt. Ltd., India. 2 Cenotaph Court, No. 28 Cenotaph Road, Taynampet Chennai India Vibro Replacement as Foundation for Tank Farms in India Mr. A. Vetriselvan, Deputy General Manager Mr. Deepak Raj, Sr. Geotechnical Engineer Keller Ground Engineering India Pvt. Ltd., India Email Addresses:

More information

Step 11 Static Load Testing

Step 11 Static Load Testing Step 11 Static Load Testing Test loading is the most definitive method of determining load capacity of a pile. Testing a pile to failure provides valuable information to the design engineer and is recommended

More information

Suitability of manufactured sand (M-Sand) as fine aggregate in mortars and concrete

Suitability of manufactured sand (M-Sand) as fine aggregate in mortars and concrete 1 Suitability of manufactured sand (M-Sand) as fine aggregate in mortars and concrete (CSIC project: CP 6597/0505/11-330 dated 5 th July 2011) Project sponsored by: Department of Mines and Geology (Govt.

More information

Determination of Ultimate Lateral Loads in Deep Foundation in Multiple Layers of Cohessionless Soils

Determination of Ultimate Lateral Loads in Deep Foundation in Multiple Layers of Cohessionless Soils Determination of Ultimate Lateral Loads in Deep Foundation in Multiple Layers of Cohessionless Soils 1 B.S.Chawhan, S.S.Quadri, 3 P.G.Rakaraddi, 1 Asst. Prof, Govt. Engineering College, Haveri-581110,

More information

A Reliable Method of Pile Load Test on Cast-in-Situ Pile Group of Existing Building for Retrofitting

A Reliable Method of Pile Load Test on Cast-in-Situ Pile Group of Existing Building for Retrofitting July 2014, Volume 8, No. 7 (Serial No. 80), pp. 881-887 Journal of Civil Engineering and Architecture, ISSN 1934-7359, USA D DAVID PUBLISHING A Reliable Method of Pile Load Test on Cast-in-Situ Pile Group

More information

Study on Shallow Funicular Concrete Shells over Rectangular Ground Plan Ratio 1:0.9

Study on Shallow Funicular Concrete Shells over Rectangular Ground Plan Ratio 1:0.9 Study on Shallow Funicular Concrete Shells over Rectangular Ground Plan Ratio 1:0.9 P. Sachithanantham 1, Dr. S. Sankaran 2, Dr. S. Elavenil 3 1 Research Scholar, Department of Civil Engineering, Bharath

More information

Foundation Engineering Prof. Mahendra Singh Department of Civil Engineering Indian Institute of Technology, Roorkee

Foundation Engineering Prof. Mahendra Singh Department of Civil Engineering Indian Institute of Technology, Roorkee Foundation Engineering Prof. Mahendra Singh Department of Civil Engineering Indian Institute of Technology, Roorkee Module - 03 Lecture - 04 Dynamic Cone Penetration Test Hello viewers, welcome back to

More information

RECTANGULAR FRP TUBES FILLED WITH CONCRETE FOR BEAM AND COLUMN APPLICATIONS

RECTANGULAR FRP TUBES FILLED WITH CONCRETE FOR BEAM AND COLUMN APPLICATIONS RECTANGULAR FRP TUBES FILLED WITH CONCRETE FOR BEAM AND COLUMN APPLICATIONS A. Z. FAM Department of Civil Engineering, Queen s University, Kingston, Ontario, Canada k7l 3N6 D. A. SCHNERCH AND S. H. RIZKALLA

More information

EXPERIMENT 13 DIRECT SHEAR TEST

EXPERIMENT 13 DIRECT SHEAR TEST 158 EXPERIMENT 13 DIRECT SHEAR TEST Purpose: This test is performed to determine the consolidated-drained shear strength of a sandy to silty soil. The shear strength is one of the most important engineering

More information

Satish Chandra.C 1, Gyanen.Takhelmayum 2, Deepa.T 3 Asst. Professor GAT, Asst. Professor GSSIT, Lecturer GSSIT I. INTRODUCTION

Satish Chandra.C 1, Gyanen.Takhelmayum 2, Deepa.T 3 Asst. Professor GAT, Asst. Professor GSSIT, Lecturer GSSIT I. INTRODUCTION Study on Flow and Compressive Strength Properties of Mortars Using Fly Ash and Lime Satish Chandra.C 1, Gyanen.Takhelmayum 2, Deepa.T 3 Asst. Professor GAT, Asst. Professor GSSIT, Lecturer GSSIT Abstract:

More information

Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand

Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand M. S. Dixit Research Scholar, Department of Civil Engineering, Government College of Engineering, Aurangabad (Maharashtra State),

More information

EFFECT OF GEOGRID REINFORCEMENT ON LOAD CARRYING CAPACITY OF A COARSE SAND BED

EFFECT OF GEOGRID REINFORCEMENT ON LOAD CARRYING CAPACITY OF A COARSE SAND BED International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 2016, pp. 01 06, Article ID: IJCIET_07_03_001 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3

More information

APPLICATION OF REINFORCING METHODS FOR EXISTING PILE FOUNDATION ON SOFT GROUND (IN-CAP METHOD)

APPLICATION OF REINFORCING METHODS FOR EXISTING PILE FOUNDATION ON SOFT GROUND (IN-CAP METHOD) APPLICATION OF REINFORCING METHODS FOR EXISTING PILE FOUNDATION ON SOFT GROUND (IN-CAP METHOD) Abstract Hisashi Fukada 1, Koji Kato 2, Mamoru Aoyagi 3, Hirokazu Inagawa 4 and Yukitake Shioi 5 The foundations

More information

Effect of Local and Global Scour on Lateral Response of Single Piles in Different Soil Conditions

Effect of Local and Global Scour on Lateral Response of Single Piles in Different Soil Conditions Engineering, 2012, 4, 297-306 http://dx.doi.org/10.4236/eng.2012.46039 Published Online June 2012 (http://www.scirp.org/journal/eng) Effect of Local and Global Scour on Lateral Response of Single Piles

More information

Bridge Engineering Seminar

Bridge Engineering Seminar Bridge Engineering Seminar Micropile Foundations for Bridges Lexington, KY Dan Thome, P.E. January 10, 2012 Micropiles Overview Installation Techniques Applications/Case Histories Design Load Testing Reasons

More information

METHOD OF STATEMENT FOR STATIC LOADING TEST

METHOD OF STATEMENT FOR STATIC LOADING TEST Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents

More information

Numerical Analysis of Piles in Layered Soils: A Parametric Study

Numerical Analysis of Piles in Layered Soils: A Parametric Study Numerical Analysis of Piles in Layered Soils: A Parametric Study Ravi Kumar Reddy C #1 Padmakar K C #2, Manjari M #3, Ekasaikumar CH #4, Saikumar K P R K #5 # Department of Civil Engineering, K L University

More information

Shaft Friction of Bored Piles in Hard Clay

Shaft Friction of Bored Piles in Hard Clay Pak. J. Engg. & Appl. Sci. Vol. 3 Jul 2008 (p.54 60) Shaft Friction of Bored Piles in Hard Clay A. Akbar 1, S. Khilji 1, S.B. Khan 1, M.S.Qureshi 1 and M. Sattar 2 1 Civil Engineering Department, University

More information

Communication Tower Foundation Selection Criteria

Communication Tower Foundation Selection Criteria Communication Tower Foundation Selection Criteria Introduction This foundation selection criteria document has been prepared by the Engineering Specialties Group as a resource for public and private entities,

More information

Dynamic testing in sensitive & difficult soil conditions

Dynamic testing in sensitive & difficult soil conditions Dynamic testing in sensitive & difficult soil conditions Morgano, C.M., White B.A. & Allin, R.C. GRL Engineers, Inc., Cleveland, Ohio, USA Keywords: dynamic testing, radiation damping, set-up, relaxation,

More information

A SEISMIC RETROFITTING APPLICATION BY MEANS OF MULTI-HELIX MICROPILES. Shigeo Kanai 1

A SEISMIC RETROFITTING APPLICATION BY MEANS OF MULTI-HELIX MICROPILES. Shigeo Kanai 1 A SEISMIC RETROFITTING APPLICATION BY MEANS OF MULTI-HELIX MICROPILES Shigeo Kanai 1 Abstract The Multi-helix Micropile method utilizes a unique method of directly screwing a small steel pipe pile with

More information

Address for Correspondence

Address for Correspondence Research Paper EXPERIMENTAL STUDY OF AN ANGLE SHAPED FOOTING UNDER DYNAMIC LOADING Pancham Kumar 1, Hemant Mahiyar 2 Address for Correspondence 1 Assistant Professor CWEM (Central University of Jharkhand)

More information

6.1 Masonry Retaining Walls

6.1 Masonry Retaining Walls 6.1 Masonry Retaining Walls Introduction This section has been prepared to provide designers, local authorities and builders with some standard design details for reinforced concrete masonry retaining

More information

Micropiles for Structural Support. Elarabi, Abbas

Micropiles for Structural Support. Elarabi, Abbas Paper 1 Elarabi, H.; Abbas A., Micropiles for Structural Support Accepted for publication in International Journal of Engineering Sciences & Research Technology, September 2014 issue. Micropiles for Structural

More information

A Study of the Behavior of Stone Column in Local Soft and Loose Layered Soil

A Study of the Behavior of Stone Column in Local Soft and Loose Layered Soil A Study of the Behavior of Stone Column in Local Soft and Loose Layered Soil Pradip Das Post Graduate Student Civil Engineering Department, National Institute of Technology, Agartala, India e-mail: pradip1000y@gmail.com

More information

BEHAVIOR OF FLOATING PILES IN LIQUEFIABLE SOILS

BEHAVIOR OF FLOATING PILES IN LIQUEFIABLE SOILS th International Conference on Earthquake Geotechnical Engineering June 5-8, 7 Paper No. 165 BEHAVIOR OF FLOATING PILES IN LIQUEFIABLE SOILS Ahmet PAMUK 1 and Thomas F. ZIMMIE ABSTRACT Centrifuge tests

More information

ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 8, NO. 5 (2007) PAGES

ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 8, NO. 5 (2007) PAGES ASIAN JOURNAL OF CIVIL ENGINEERING (BUILDING AND HOUSING) VOL. 8, NO. 5 (2007) PAGES 479-489 STEEL FIBERS AS REPLACEMENT OF WEB REINFORCEMENT FOR RCC DEEP BEAMS IN SHEAR S.K. Madan a, G. Rajesh Kumar b

More information

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and

More information

Strengthening of RC Column using GFRP and CFRP

Strengthening of RC Column using GFRP and CFRP Strengthening of RC Column using GFRP and CFRP K. P. Jaya Anna University, Chennai, India Jessy Mathai Hindustan Institute of Technology & Science, Chennai, India SUMMARY Seismic retrofitting of constructions

More information

Construction and testing of marine bridge foundation

Construction and testing of marine bridge foundation Construction and testing of marine bridge foundation By Sing-lok CHIU, AECOM Zheng-ru Fang, CHEC Construction (M) Sdn Bhd (CHEC) Shi-jing, LIU, China Habour Engineering Company Ltd (CHEC) Presented by

More information

Using Shear Strength Reduction Method for 2D and 3D Slope Stability Analysis. Thamer Yacoub, Ph.D. P.Eng. President, Rocscience Inc.

Using Shear Strength Reduction Method for 2D and 3D Slope Stability Analysis. Thamer Yacoub, Ph.D. P.Eng. President, Rocscience Inc. Using Shear Strength Reduction Method for 2D and 3D Slope Stability Analysis Thamer Yacoub, Ph.D. P.Eng. President, Rocscience Inc. Toronto, Canada Annual Kansas City Geotechnical Conference 2016 Outline

More information

AXIAL BEHAVIOR OF CONCRETE-FILLED STEEL TUBULAR BEAM COLUMN JOINT

AXIAL BEHAVIOR OF CONCRETE-FILLED STEEL TUBULAR BEAM COLUMN JOINT Int. J. Struct. & Civil Engg. Res. 2014 Parvin Barkath M and Shankar P, 2014 Research Paper AXIAL BEHAVIOR OF CONCRETE-FILLED STEEL TUBULAR BEAM COLUMN JOINT Parvin Barkath M 1* and Shankar P 2 ISSN 2319

More information

Determination of Thermal Conductivity of Coarse and Fine Sand Soils

Determination of Thermal Conductivity of Coarse and Fine Sand Soils Proceedings World Geothermal Congress Bali, Indonesia, - April Determination of Thermal Conductivity of Coarse and Fine Sand Soils Indra Noer Hamdhan 1 and Barry G. Clarke 2 1 Bandung National of Institute

More information

Module 5 : Design of Deep Foundations. Lecture 25 : Pile Groups [ Section 25.1 : Different types of pile groups ]

Module 5 : Design of Deep Foundations. Lecture 25 : Pile Groups [ Section 25.1 : Different types of pile groups ] Lecture 25 : Pile Groups [ Section 25.1 : Different types of pile groups ] Objectives In this section you will learn the following Different types of pile groups Lecture 25 : Pile Groups [ Section 25.1

More information

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams 111 Nonlinear Models of Reinforced and Post-tensioned Concrete Beams ABSTRACT P. Fanning Lecturer, Department of Civil Engineering, University College Dublin Earlsfort Terrace, Dublin 2, Ireland. Email:

More information

IJESRT. Scientific Journal Impact Factor: 3.449 (ISRA), Impact Factor: 2.114 [205] [Elarabi, 3(12): December, 2014] ISSN: 2277-9655

IJESRT. Scientific Journal Impact Factor: 3.449 (ISRA), Impact Factor: 2.114 [205] [Elarabi, 3(12): December, 2014] ISSN: 2277-9655 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Micropiles for Structural Support Elarabi*, Abbas *Associate Professor at Building and Road Research Institute, University of

More information

Module 7 (Lecture 26) RETAINING WALLS

Module 7 (Lecture 26) RETAINING WALLS Module 7 (Lecture 26) RETAINING WALLS Topics 1.1 COMMENTS RELATING TO STABILITY 1.2 DRAINAGE FROM THE BACKFILL OF THE RETAINING WALL 1.3 PROVISION OF JOINTS IN RETAINING-WALL CONSTRUCTION 1.4 GRAVITY RETAINING-WALL

More information

Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions

Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions Peyman Amini Motlagh, Ali Pak Abstract Seismic retrofitting of important structures is essential in seismological

More information

Experimental Study of Dynamic Characteristics on Composite Foundation with CFG Long Pile and Rammed Cement-Soil Short Pile

Experimental Study of Dynamic Characteristics on Composite Foundation with CFG Long Pile and Rammed Cement-Soil Short Pile Open Journal of Civil Engineering, 2014, 4, 1-12 Published Online March 2014 in SciRes. http://www.scirp.org/journal/ojce http://dx.doi.org/10.4236/ojce.2014.41001 Experimental Study of Dynamic Characteristics

More information

EXAMPLE. HelixPile software program (Version 2014) Version 1.0 Issued: 24-April-2014 Deep Excavation LLC DEEP EXCAVATION LLC

EXAMPLE. HelixPile software program (Version 2014) Version 1.0 Issued: 24-April-2014 Deep Excavation LLC  DEEP EXCAVATION LLC EXAMPLE HelixPile software program (Version 2014) Version 1.0 Issued: 24-April-2014 Deep Excavation LLC www.deepexcavation.com 1 A. Project description This example will present a helical pile design example

More information

c. Heavy Tamping and Dynamic Consolidation (Dynamic compaction )

c. Heavy Tamping and Dynamic Consolidation (Dynamic compaction ) c. Heavy Tamping and Dynamic Consolidation (Dynamic compaction ) Dynamic compaction involves lifting and dropping a heavy weight several times in one place. The process is repeated on a grid pattern across

More information

Effects of Particle Size on the Shear Behavior of Coarse Grained Soils Reinforced with Geogrid

Effects of Particle Size on the Shear Behavior of Coarse Grained Soils Reinforced with Geogrid Materials 2014, 7, 963-979; doi:10.3390/ma7020963 Article OPEN ACCESS materials ISSN 1996-1944 www.mdpi.com/journal/materials Effects of Particle Size on the Shear Behavior of Coarse Grained Soils Reinforced

More information

SKIN FRICTION IN SHALE: RESULTS OF THE HWY. 81 BRIDGE, YANKTON, SD DRILLED SHAFT LOAD TEST

SKIN FRICTION IN SHALE: RESULTS OF THE HWY. 81 BRIDGE, YANKTON, SD DRILLED SHAFT LOAD TEST SKIN FRICTION IN SHALE: RESULTS OF THE HWY. 81 BRIDGE, YANKTON, SD DRILLED SHAFT LOAD TEST Scott M. Mackiewicz, PhD, PE, Kleinfelder, 7802 Barton, Lenexa, Kansas, USA Omar Qudus, PE, Nebraska Department

More information

Effective reinforcement layout for skew slabs

Effective reinforcement layout for skew slabs Effective reinforcement layout for skew slabs A Kabir*, Bangladesh University of Engineering & Technology, Bangladesh S M Nizamud-Doulah, Bangladesh nstitute of Technology, Bangladesh M Kamruzzaman, Bangladesh

More information

Uplift Resistance of Coated Driven Steel Piles. 1Professor, University of Massachusetts, Amherst, Ma

Uplift Resistance of Coated Driven Steel Piles. 1Professor, University of Massachusetts, Amherst, Ma Uplift Resistance of Coated Driven Steel Piles Alan J. Lutenegger 1, F. ASCE and Jahan Khalili 2 1Professor, University of Massachusetts, Amherst, Ma. 13 2 Geotechnical Engineer, GZA Geoenvironmental,

More information

DFI Electric Power Systems Foundations Working Group

DFI Electric Power Systems Foundations Working Group DFI Electric Power Systems Foundations Working Group Utility Survey Questions First Name: Last Name: Company Name: Work Phone: Email Address: City: State/Province: Country: A. Demographics 1. Please select

More information

INTERNATIONAL JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (IJCIET)

INTERNATIONAL JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (IJCIET) INTERNATIONAL JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (IJCIET) International Journal of Civil Engineering and Technology (IJCIET), ISSN 97 38 (Print), ISSN 97 31(Online) Volume, Issue 3, May - June

More information

Mechanical Splicer for Precast, Prestressed Concrete Piles

Mechanical Splicer for Precast, Prestressed Concrete Piles Mechanical Splicer for Precast, Prestressed Concrete Piles Uri Korin, Ph.D. Engineering Consultant Haifa, Israel This article describes an innovative type of mechanical splicer for extending the length

More information

Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate

Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate Addendum HELICAL PULLDOWN Micropile (HPM) Introduction The HPM is a system for constructing a grout column around the shaft of a standard Helical Screw Foundation (see Figure A1). To begin the process,

More information

13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 162

13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 162 13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 24 Paper No. 162 A STUDY ON THE CHARACTERISTICS OF DYNAMIC HORIZONTAL SUBGRADE REACTION FOR DIFFERENT TYPES OF GROUND

More information

Procedures for Long Term Testing of Reinforced Concrete Tension Specimens

Procedures for Long Term Testing of Reinforced Concrete Tension Specimens Applied Mechanics and Materials Vols. 1-2 (2004) pp 239-244 (2004) Trans Tech Publications, Switzerland doi:10.4028/www.scientific.net/amm.1-2.239 Procedures for Long Term Testing of Reinforced Concrete

More information

GROUND IMPROVEMENT GROUND TREATMENT USING GROUTING

GROUND IMPROVEMENT GROUND TREATMENT USING GROUTING Lecture 20 NPTEL Course GROUND IMPROVEMENT GROUND TREATMENT USING GROUTING Prof. G L Sivakumar Babu Department of Civil Engineering Indian Institute of Science Bangalore 560012 Email: gls@civil.iisc.ernet.in

More information

BEARING CAPACITY INVESTIGATION OF SILTY SANDY SOIL LAYER USING KUNZELSTAB TEST. C. Kererat

BEARING CAPACITY INVESTIGATION OF SILTY SANDY SOIL LAYER USING KUNZELSTAB TEST. C. Kererat BEARING CAPACITY INVESTIGATION OF SILTY SANDY SOIL LAYER USING KUNZELSTAB TEST C. Kererat Rajamangala University of Technology Rattanakosin Wangklaikangwon Campus, Faculty of Engineering, Department of

More information

Manual: Handheld CPT Penetrometer HANDHELD CPT PENETROMETER

Manual: Handheld CPT Penetrometer HANDHELD CPT PENETROMETER HANDHELD CPT PENETROMETER The hand-pushed CPT penetrometer is a portable and handy tool for simple, quick and accurate assessment of soil conditions for various purposes. It is easy and straightforward

More information

ctbuh.org/papers Title: The Tallest Concrete Building in Shanghai, China Plaza 66

ctbuh.org/papers Title: The Tallest Concrete Building in Shanghai, China Plaza 66 ctbuh.org/papers Title: The Tallest Concrete Building in Shanghai, China Plaza 66 Authors: Subjects: Keywords: Richard Tomasetti, Thornton Tomasetti Dennis Poon, Thornton Tomasetti Ling-en Hsaio, Thornton

More information

DEEP FOUNDATIONS. Dr. Youssef Gomaa Youssef. Dr. Youssef Gomaa Youssef 1

DEEP FOUNDATIONS. Dr. Youssef Gomaa Youssef. Dr. Youssef Gomaa Youssef 1 DEEP FOUNDATIONS Dr. Youssef Gomaa Youssef Dr. Youssef Gomaa Youssef 1 Textbook: Tomlinson, J.J., 1977. Pile Design and Construction Practice, Garden City Press Ltd., Letchworth. Canadian Foundation Engineering

More information

Seismic Evaluation of Full-Moment Connection CISS Piles/Foundation Systems. Pedro F. Silva 1

Seismic Evaluation of Full-Moment Connection CISS Piles/Foundation Systems. Pedro F. Silva 1 Seismic Evaluation of Full-Moment Connection CISS Piles/Foundation Systems Abstract Pedro F. Silva 1 Analytical models were developed to evaluate the seismic performance of laterally loaded pile groups.

More information