1 International Journal of Civil Engineering Research. ISSN Volume 5, Number 4 (2014), pp Research India Publications A Model Study of Micropile Group Efficiency under Axial Loading Condition Nihar Gogoi 1, Sanandam Bordoloi 2 and Binu Sharma 3 1, 2, 3 Civil Engineering Department, Assam Engineering College, Jalukbari, Guwahati, India. Abstract The application of micropiles in retrofitting or as structural support is a technically viable and economically feasible solution in many situations. Micropiles are especially useful in places where heavy machinery cannot gain access in order to lay down conventional piles. As suggested by their name, micropiles have a smaller diameter than conventional pile. These piles comprise of a central steel reinforcement surrounded by grout that fastens the pile with the soil. Owing to its wide application, it is logical to study the interaction between the soil and micropiles under various loading conditions. This paper deals with the investigation of a model experimental study of group micropiles of different length to diameter ratio as well as different spacing between the piles in the group. The piles were installed in sand bed of 50% relative density and subjected to axial loading condition. Ratio of length to diameter has been found to be a major factor that influences ultimate axial resistance of the group. Group efficiencies of micropiles groups were determined at length to diameter ratio varying from 30 to 70 and at 2D, 4D and 6D spacing between the piles. Keywords: Micropiles, pile group efficiency. 1. Introduction Micropiles are piles with a smaller diameter (generally ranging from piles of about 100mm to 250 mm) than conventional piles. These piles comprise of a central steel reinforcement surrounded by grout that fastens the pile with the soil. The grout is interjected under a pressure ranging from 0.8Mpa to 1Mpa. The high pressure grouting causes the fluid part of the cement mix to penetrate into the interstices of the

2 324 Sanandam Bordoloi et al surrounding soil; thereby creating a transition zone comprising of grout mixed soil between the body of the micropile and the soil, resulting in a strong grout-ground bond. The introduction of micropiles occurred in Italy in the year 1950 as a means for underpin old historic buildings and monuments. Micropiles have been gradually gaining popularity around the world since the late 1980 s when the method gained acceptance as a mean to underpin the existing structures. Micropiles exhibit high skin friction, as a result of which the load carrying capacity of micropiles is higher than that anticipated by the conventional bearing capacity theory. Its quick response to the slightest movement of the structure is one of its most notable features. Even when the load reaches crushing strength of concrete they display settlement of only a few mm. Micropile systems are also known to demonstrate flexibility under dynamic loading. Another distinguished feature of micropile is that retrofitting methods that employ micropiles can be applied to liquefied ground. Furthermore, its small boring diameter allows its construction almost at any ground condition and with equipment smaller than that required for a conventional pile. In this investigation a model experimental study has been undertaken on micropiles. Single piles having different length to diameter ratio, and grouped piles having different length to diameter as well as different centre-to-centre spacing were installed in a sand bed having a 50% relative density. The piles and pile groups were subjected to downward vertical axial load. Subsequently their ultimate bearing capacities were determined and the load-settlement curves were plotted in order to determine their group efficiency. 2. Experimental Setup 2.1. Properties of sand The micropiles of different L/D ratio were installed in sand placed inside a model tank of size (1.7m x 1.5m x 0.93m). The coefficient of curvature and uniformity coefficient of the sand were found out to be 0.98 and 2.08 respectively. The effective grain size of the sand was determined as 0.22mm. The minimum void ratio and maximum void ratio were ascertained as 0.68 and 0.88 respectively. The specific gravity of the sand was found out to be Since the tank used for the experiment was to be filled with uniform density, rainfall technique was adopted. Sand was poured uniformly through a strainer from a constant height of 60cm from the surface of the sand bed. The corresponding relative density obtained in the sand was 50%. For sand with relative density of 50%, density and angle of internal friction (ɸ) was found to be 1.5 gm/cc and 38 o respectively Installation of the micropiles Micropiles were installed as single piles of L/D ratios of 30, 50 and 70, and as square groups of 4 piles per group with spacing of 2D, 4D and 6D with L/D ratios of 30, 50 and 70 for each of the spacing conditions. Steel pipes of external diameter 1.2cm and internal diameter 1.0cm were used for casting the piles. At the lower end of the pile a conical wooden shoe was attached. A 2mm diameter mild steel rod was fixed to the

3 A Model Study of Micropile Group Efficiency under Axial Loading Condition 325 wooden shoe and inserted into the pipe as reinforcement. Keeping the steel pipe perfectly vertical, it was driven into the sand manually along with the steel reinforcement and the wooden shoe. The piles were then grouted with cement slurry of water cement ratio 0.6 under a constant gravity head of 100cm. Pile caps were constructed using wooden framework and were reinforced with steel wire mesh Measurement of load and deflection Application of load was carried out using a mechanical jack system where the jack was fixed such that it could slide when required. The proving ring with a constant of 0.99 kg per division (Figure 2) was fixed to the top of the pile cap by ball and socket arrangement. Load tests were carried out four days after grouting. Load-deflection test was done according to the norms of IS 2911 (Pt-4) 1985 code of practice for load test on group piles. Load was measured by means of the proving ring and displacement was measured by a dial gauge fixed to the pile cap. 3. Test Results 3.1. Single micropiles Individual micropiles were cast with L/D ratios of 30, 50 and 70. On the load versus displacement curve (Figure 3), the point at which the curves reach their peak values from which the pile load reduces with further displacement is taken as the ultimate load capacity of the micropile. Figure 4 shows the plot of ultimate axial load resistance versus L/D ratio. It is observed from the plot that the ultimate axial resistance gradually increase from L/D 30 to L/D 70. Fig. 1: Load versus settlement plot for single pile at L/D= 30, 50, 70.

4 326 Sanandam Bordoloi et al Fig. 2: Ultimate load versus L/D ratio for single pile Micropile Groups Micropiles groups of the same L/D ratio as that of the single piles were cast. The pile groups consisted of 4 piles at spacing of 2D, 4D and 6D. Because of space limitations, only the variations in axial pile capacity with the pile head displacement for pile group 4D are shown in Figure 5. Figure 5 clearly shows that the load gradually increases with increase in displacement until the load displacement curves reach their peak values from which the pile load reduces with further continuous displacement. Thus, the ultimate load capacities of the pile groups were determined. It can be seen in Figure 5 that the ultimate load capacity increases with the increase in L/D ratio. Further, with increase in L/D ratio of the pile groups exhibit a decrease in the settlement before failure. Fig. 3: Load versus settlement plot for pile groups at 4D spacing.

5 A Model Study of Micropile Group Efficiency under Axial Loading Condition 327 Fig. 4: Load Vs L/D ratio for 2D spacing. Fig. 5: Load Vs L/D ratio for 4D spacing. Fig. 6: Load Vs L/D ratio for 6D spacing.

6 328 Sanandam Bordoloi et al Figure 6, 7 and 8 show the variation of ultimate axial load with length to diameter ratio of the micropile groups at the three different spacing. It is seen that all the three plots show an almost identical trend. L/D ratio of the micropile groups could not be increased due to the limited tank depth of 0.93 m. 4. Group Efficiency There has been quite a lot of research regarding the group efficiency of micropiles. However, the results have not been in agreement and a reasonable explanation has not yet been arrived at. In the study of piles under vertical loading, a parameter termed as efficiency is often used to evaluate the group effect: η = (1) where η= efficiency of the pile group; Q g = axial capacity of pile group; Q s = axial capacity of single pile; and n = number of pile group. The group efficiencies of the pile groups at 2D, 4D, and 6D spacing had been determined. Table 1 shows the group efficiency of the various pile groups that we studies in our experiment. Table 1: Group efficiency table for different L/D ratio and spacing. Length(cm) L/D ratio Q u (N) Ultimate Load (N) Group Efficiency 2D 4D 6D 2D 4D 6D Fig. 7: Group efficiency (η) versus Spacing/Diameter ratio

7 A Model Study of Micropile Group Efficiency under Axial Loading Condition 329 Group efficiency versus spacing/diameter ratio is shown in Figure 11. The observation shows that the group efficiency increases when the spacing increases from 2D to 4D. However, when the spacing is further increased to 6D, the group efficiency shows a very insignificant change. Thus, maximum group efficiency is observed when the spacing in 4D and the maximum value increases with increase in L/D ratio. The results also show that positive group effect is only observed in the piles groups with L/D ratio 50 and 70 at 4D and 6D spacing. 5. Comparision with Previous Literature Lizzi (1985) reported model test results of group efficiency of micropiles on coarse sand. The experimental consisted of four series of tests, with piles length of 50, 100, 150, and 200 pile diameters, respectively. Each series consisted of 6 groups of 3 piles each, spaced at 2 to 7 diameters, plus additional single piles. The results of the tests are as summarized in the Figure 13. The result showed positive group effect at spacing ranging from 2 to 6 times the pile diameter. Fig. 8: Efficiency Vs Spacing (Lizzi 1985). Comparing the result of the present experiment with that of Lizzi, it was observed that both results show a similar trend for pile groups with L/D ratio of 50 and 70. A positive group effect was observed in all of the piles groups of lengths 50D to 200D studies by Lizzi, while the present experiment show positive group effect in pile groups with length 50D and 70D, and not for 30D. Nonetheless, an increase in the group efficiency from 2D to 4D spacing, similar to the Lizzi s results, has been invariably observed in all the piles groups. Again, it is seen that Lizzi s result shows an increase in the maximum efficiency with increase in depth, similar to the findings of the current experiment.

8 330 Sanandam Bordoloi et al Furthermore, O neill s (1983) study on group of 4 piles conducted on medium dense to dense sand (relative density 50% to 90%) also shows that there is an increase in group efficiency from 2D to 4D spacing and very little decrease thereafter. It can be seen in Figure 14 that the curve is quite similar to the one deduced by the current experiment. Fig. 9: Group efficiencies from test model pile groups in cohesionless soil subjected to vertical loads reported by O neill (1983), Lizzie (1978) and Cambefort (1953) Based on the comparisons, it is seen that there is inconsistency of results of the various researcher workers. However, it is observed that for micropile groups of four, maximum group efficiency is observed when the spacing between the piles is 4D. Most of the curves (group efficiency versus spacing) have shown a similar trend of increase followed by a gradual decrease. 6. Conclusions Based on the results of the present experimental investigation, some conclusions are drawn with respect to ultimate load capacity of micropiles and micropile groups. Ultimate load capacity increased with the increase in length to diameter ratio but the increase was not linear. Furthermore, the settlement before reaching the ultimate load capacity decreased with the increase in length to diameter ratio. A few conclusions were also drawn regarding group efficiency of micropiles. The efficiency increased with increase in spacing between piles in a group up to 4D then slightly decreases with the increase in spacing. It was seen that the maximum efficiency occurs when the spacing between piles is 4D. The maximum efficiency is dependent on L/D ratio and increases with the increase with L/D ratio.

9 A Model Study of Micropile Group Efficiency under Axial Loading Condition 331 Further comprehensive experimental work, covering a broad range of pile characteristics and soil properties, is needed to get definitive conclusions about the effects of spacing on efficiency of pile groups. References [1] Lizzi, F., The Reticolo Di PALI RADICE (Reticulated Root pile) for the improvement of soil resistance physical aspects and design approaches-viii ECSMFE, Helsinki, 1983, pp [2] Sabini, G. and Sapio, G, Behaviour of small diameter piles under axial load, X ICSMFE, Vol.-2, 1981, pp [3] O Neil, M.W. and Pierry, R.F., Behaviour of mini-grouted piles used in foundation underpinning in Beaumont Clay, Houston, Texas, U.S.A. Proceeding of the International Conference piling and deep foundation London/15, 1 May 1989, pp [4] Benslimane, A., Juran, I., Hanna, S. and Drabkin, S., Seismic Behaviour of Micropile System. Proceedings of sessions of Geo-congress 98, October 18-21, 1998, Boston, Massachusetts. [5] Deshmukh, A.M. and Ganpule, V.T.,Design and Construction of mini grouted piles in Bombay region. Pile talk international, July 1990: Jakarta, Indonesia, pp [6] Balasingham Muhunthan, Shanji Shu, and Adrian Rodriguez Marek, Sand State and Performance Analysis of Micropiles, FHWA, June 2006, pp

10 332 Sanandam Bordoloi et al

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil

A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department

More information

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus Vol.3, Issue.1, Jan-Feb. 2013 pp-284-290 ISSN: 2249-6645 Measurement of Soil Parameters by Using Penetrometer Needle Apparatus Mahmoud M. Abu zeid, 1 Amr M. Radwan, 2 Emad A. Osman, 3 Ahmed M.Abu-bakr,

More information

Paper - 4 - The relation of Micropile Diameters in case of Pressure casting and non-pressure casting (30)

Paper - 4 - The relation of Micropile Diameters in case of Pressure casting and non-pressure casting (30) Paper - 4 - Elarabi, H.; Abbas A., The relation of Micropile Diameters in case of Pressure casting and non-pressure casting,magnt Research Report (ISSN. 1444-8939), Vol.2 (2) Accepted for publication The

More information

THE EFFECT OF IMPROVEMENT SURROUNDING SOIL ON BORED PILE FRICTION CAPACITY

THE EFFECT OF IMPROVEMENT SURROUNDING SOIL ON BORED PILE FRICTION CAPACITY International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 1, Jan-Feb 2016, pp. 260-273, Article ID: IJCIET_07_01_022 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=1

More information

EFFECT OF GEOGRID REINFORCEMENT ON LOAD CARRYING CAPACITY OF A COARSE SAND BED

EFFECT OF GEOGRID REINFORCEMENT ON LOAD CARRYING CAPACITY OF A COARSE SAND BED International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 2016, pp. 01 06, Article ID: IJCIET_07_03_001 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3

More information

METHOD OF STATEMENT FOR STATIC LOADING TEST

METHOD OF STATEMENT FOR STATIC LOADING TEST Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents

More information

Step 11 Static Load Testing

Step 11 Static Load Testing Step 11 Static Load Testing Test loading is the most definitive method of determining load capacity of a pile. Testing a pile to failure provides valuable information to the design engineer and is recommended

More information

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and

More information

Figure 2.31. CPT Equipment

Figure 2.31. CPT Equipment Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3

More information

IJESRT. Scientific Journal Impact Factor: 3.449 (ISRA), Impact Factor: 2.114 [205] [Elarabi, 3(12): December, 2014] ISSN: 2277-9655

IJESRT. Scientific Journal Impact Factor: 3.449 (ISRA), Impact Factor: 2.114 [205] [Elarabi, 3(12): December, 2014] ISSN: 2277-9655 IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Micropiles for Structural Support Elarabi*, Abbas *Associate Professor at Building and Road Research Institute, University of

More information

Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions

Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions Peyman Amini Motlagh, Ali Pak Abstract Seismic retrofitting of important structures is essential in seismological

More information

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur Lecture No. # 13 (Refer Slide Time: 00:18) So last class, it was

More information

Stress and deformation of offshore piles under structural and wave loading

Stress and deformation of offshore piles under structural and wave loading Stress and deformation of offshore piles under structural and wave loading J. A. Eicher, H. Guan, and D. S. Jeng # School of Engineering, Griffith University, Gold Coast Campus, PMB 50 Gold Coast Mail

More information

An Automatic Kunzelstab Penetration Test

An Automatic Kunzelstab Penetration Test An Automatic Kunzelstab Penetration Test Yongyuth Sirisriphet 1, Kitidech Santichaianant 2 1 Graduated student: Faculty of Industrial Education in and Technology. King Mongkut's University of Technology

More information

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation

Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 JRHill@HaywardBaker.com

More information

Numerical Simulation of CPT Tip Resistance in Layered Soil

Numerical Simulation of CPT Tip Resistance in Layered Soil Numerical Simulation of CPT Tip Resistance in Layered Soil M.M. Ahmadi, Assistant Professor, mmahmadi@sharif.edu Dept. of Civil Engineering, Sharif University of Technology, Tehran, Iran Abstract The paper

More information

Pent Up Load and Its Effect on Load Test Evaluation

Pent Up Load and Its Effect on Load Test Evaluation Nicholson Construction Company 12 McClane Street Cuddy, PA 15031 Telephone: 412-221-4500 Facsimile: 412-221-3127 Pent Up Load and Its Effect on Load Test Evaluation by T.D. Richards Jr., P.E. Nicholson

More information

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS Page 1 of 9 SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS 1. GENERAL REQUIREMENTS 1. Description of Work: This work consists of furnishing all materials, equipment and

More information

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA

DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA DIRECT SHEAR TEST OBJEVTIVES To determine the shear strength parameters for a

More information

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2 Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2 W.F. Bawden, Chair Lassonde Mineral Engineering Program, U. of Toronto, Canada J.D. Tod, Senior Engineer, Mine Design

More information

PILE FOUNDATIONS FM 5-134

PILE FOUNDATIONS FM 5-134 C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics

More information

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope Rakesh Sidharthan 1 Gnanavel B K 2 Assistant professor Mechanical, Department Professor, Mechanical Department, Gojan engineering college,

More information

SUGGESTION ABOUT DETERMINATION OF THE BEARING CAPACITY OF PILES ON THE BASIS OF CPT SOUNDING TESTS

SUGGESTION ABOUT DETERMINATION OF THE BEARING CAPACITY OF PILES ON THE BASIS OF CPT SOUNDING TESTS SUGGESTION ABOUT DETERMINATION OF THE BEARING CAPACITY OF PILES ON THE BASIS OF CPT SOUNDING TESTS JóZSEF PUSZTAI About the authors Pusztai József Budapest University of Technology and Economics, Department

More information

Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load

Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load Nature of Services The company has a long history of performance of tests of piles and pile groups under a variety

More information

Numerical Analysis of Texas Cone Penetration Test

Numerical Analysis of Texas Cone Penetration Test International Journal of Applied Science and Technology Vol. 2 No. 3; March 2012 Numerical Analysis of Texas Cone Penetration Test Nutan Palla Project Engineer, Tolunay-Wong Engineers, Inc. 10710 S Sam

More information

LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO

LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO STANDARD IS: 2720 (Part 16) 1979. DEFINITION California bearing ratio is the ratio of force per unit area required to penetrate in to a soil mass with

More information

Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand

Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand Effect of Gradation on Bearing Capacity and Settlement of Reinforced Sand M. S. Dixit Research Scholar, Department of Civil Engineering, Government College of Engineering, Aurangabad (Maharashtra State),

More information

Multiproject Scheduling in Construction Industry

Multiproject Scheduling in Construction Industry Multiproject Scheduling in Construction Industry Y. Gholipour Abstract In this paper, supply policy and procurement of shared resources in some kinds of concurrent construction projects are investigated.

More information

BUTE Department of Construction Management and Technology

BUTE Department of Construction Management and Technology BUTE Department of Construction Management and Technology 02.10.2012 Definition 1: Foundation: The structure, that transmits the load of the building to the soil Definition 2: Load bearing soil (strata):

More information

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL. STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill

More information

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION

METHODS FOR ACHIEVEMENT UNIFORM STRESSES DISTRIBUTION UNDER THE FOUNDATION International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 2, March-April 2016, pp. 45-66, Article ID: IJCIET_07_02_004 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=2

More information

Design and Construction of Auger Cast Piles

Design and Construction of Auger Cast Piles Design and Construction of Auger Cast Piles 101 th Annual Road School 2015 3/11/2015 Malek Smadi, Ph.D., P.E. Principal Engineer - GEOTILL - Fishers, IN msmadi@geotill.com - www.geotill.com CONTENTS 1.

More information

Program COLANY Stone Columns Settlement Analysis. User Manual

Program COLANY Stone Columns Settlement Analysis. User Manual User Manual 1 CONTENTS SYNOPSIS 3 1. INTRODUCTION 4 2. PROBLEM DEFINITION 4 2.1 Material Properties 2.2 Dimensions 2.3 Units 6 7 7 3. EXAMPLE PROBLEM 8 3.1 Description 3.2 Hand Calculation 8 8 4. COLANY

More information

Solution for Homework #1

Solution for Homework #1 Solution for Homework #1 Chapter 2: Multiple Choice Questions (2.5, 2.6, 2.8, 2.11) 2.5 Which of the following bond types are classified as primary bonds (more than one)? (a) covalent bonding, (b) hydrogen

More information

BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD

BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD SENRA Academic Publishers, British Columbia Vol., No. 1, pp. 27-2774, February 20 Online ISSN: 0-353; Print ISSN: 17-7 BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD

More information

Estimation of Adjacent Building Settlement During Drilling of Urban Tunnels

Estimation of Adjacent Building Settlement During Drilling of Urban Tunnels Estimation of Adjacent Building During Drilling of Urban Tunnels Shahram Pourakbar 1, Mohammad Azadi 2, Bujang B. K. Huat 1, Afshin Asadi 1 1 Department of Civil Engineering, University Putra Malaysia

More information

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS

ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Proceedings of Indian Geotechnical Conference IGC-2014 December 18-20, 2014, Kakinada, India ASSESSMENT OF SHEAR WAVE VELOCITY FROM INDIRECT INSITU TESTS Kant, L., M. Tech Student, Department of Earthquake

More information

Supplier ID: 26421. Local Office: GLASGOW 69 Buchanan Street Glasgow G1 3HL

Supplier ID: 26421. Local Office: GLASGOW 69 Buchanan Street Glasgow G1 3HL M D & FOUNDATIONS MIDLANDS Supplier ID: 26421 MINI PILING PILING REINFORCED CONCRETE UNDERPINNING DRILLING & GROUTING SITE INVESTIGATION & PILE TESTING NATIONWIDE SPECIALIST PILING & FOUNDATION SERVICES

More information

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:! In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible

More information

METHOD STATEMENT HIGH STRIAN DYNAMIC TESTING OF PILE. Prepared by

METHOD STATEMENT HIGH STRIAN DYNAMIC TESTING OF PILE. Prepared by METHOD STATEMENT HIGH STRIAN DYNAMIC TESTING OF PILE Prepared by Infratech ASTM CO., LTD. Contents Chapter Description Page Contents...... 1 List of Appendix. 1 1. Introduction.. 2 2. Test Method..2 3.

More information

Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations

Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations Cambridge City Council - East Cambridgeshire District Council - Fenland District Council, Huntingdonshire

More information

PRIMA 100 FWD. Comparative measurements and experience with the portable PRIMA light FWD

PRIMA 100 FWD. Comparative measurements and experience with the portable PRIMA light FWD PRIMA 100 FWD Comparative measurements and experience with the portable PRIMA light FWD Carl Bro Pavement Consultants 0 CONTENTS 1. Introduction and background Measuring equipment Static plate bearing

More information

Pro-Lift Steel Pile Foundation Repair

Pro-Lift Steel Pile Foundation Repair Pro-Lift Steel Pile Foundation Repair Pro-Lift Steel Pile Foundation Repair System Pro-lift steel piles are designed for the stresses of Texas soils. They can have multiple steel walls, depending on the

More information

Physics Lab Report Guidelines

Physics Lab Report Guidelines Physics Lab Report Guidelines Summary The following is an outline of the requirements for a physics lab report. A. Experimental Description 1. Provide a statement of the physical theory or principle observed

More information

Stone crusher dust as a fine aggregate in Concrete for paving blocks

Stone crusher dust as a fine aggregate in Concrete for paving blocks Stone crusher dust as a fine aggregate in Concrete for paving blocks Radhikesh P. Nanda 1, Amiya K. Das 2, Moharana.N.C 3 1 Associate Professor, Department of Civil Engineering, NIT Durgapur, Durgapur

More information

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand Discovery ANALYSIS The International Daily journal ISSN 2278 5469 EISSN 2278 5450 2015 Discovery Publication. All Rights Reserved Effect of grain size, gradation and relative density on shear strength

More information

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils

Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils Stephen W. Lacz 1, M. ASCE, P.E. and Richard C. Wells 2, F. ASCE, P.E. 1 Senior Professional, Trigon Kleinfelder, Inc., 313 Gallimore

More information

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode INDIRECT METHODS SOUNDING OR PENETRATION TESTS STANDARD PENETRATION TEST (SPT) Reference can be made to IS 2131 1981 for details on SPT. It is a field edtest to estimate e the penetration e resistance

More information

Toe Bearing Capacity of Piles from Cone Penetration Test (CPT) Data

Toe Bearing Capacity of Piles from Cone Penetration Test (CPT) Data Toe Bearing Capacity of Piles from Cone Penetration Test (CPT) Data Abolfazl Eslami University of Ottawa, Civil Engineering Department PREPRINT International Symposium on Cone Penetrometer Testing, CPT

More information

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05 Dimensional and Structural Data for Elliptical Pipes 21/09/05 Page 1 of 15 1. Foreword This document details a method for the structural design of Stanton Bonna Elliptical pipes for the common conditions

More information

Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test. Murad Abu-Farsakh, Ph.D., P.E.

Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test. Murad Abu-Farsakh, Ph.D., P.E. Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test Murad Abu-Farsakh, Ph.D., P.E. Louisiana Transportation Research Center Louisiana State University

More information

CHAPTER 4 4 NUMERICAL ANALYSIS

CHAPTER 4 4 NUMERICAL ANALYSIS 41 CHAPTER 4 4 NUMERICAL ANALYSIS Simulation is a powerful tool that engineers use to predict the result of a phenomenon or to simulate the working situation in which a part or machine will perform in

More information

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning May 7th 2013: Dominique Deschamps Scope of the paper Presentation of the project Cause of cracks

More information

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives In this section you will learn the following Penetrometer Tests Standard penetration test Static cone penetration test Dynamic cone

More information

The University of Birmingham (Live System)

The University of Birmingham (Live System) The University of Birmingham (Live System) Behaviour of Structural Insulated Panels (SIPs) under both short-term and long-term loadings Yang, Jian; Rungthonkit, Prathan Document Version Author final version

More information

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone

PART TWO GEOSYNTHETIC SOIL REINFORCEMENT. Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone GEOSYNTHETIC SOIL REINFORCEMENT Martin Street Improvements, Fredonia, Wisconsin; Keystone Compac Hewnstone DESIGN MANUAL & KEYWALL OPERATING GUIDE GEOSYNTHETIC SOIL REINFORCEMENT Keystone retaining walls

More information

USE OF CONE PENETRATION TEST IN PILE DESIGN

USE OF CONE PENETRATION TEST IN PILE DESIGN PERIODICA POLYTECHNICA SER. CIV. ENG. VOL. 47, NO. 2, PP. 189 197 (23) USE OF CONE PENETRATION TEST IN PILE DESIGN András MAHLER Department of Geotechnics Budapest University of Technology and Economics

More information

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar, Volume, Special Issue, ICSTSD Behaviour of Steel Bracing as a Global Retrofitting Technique Miss S. S. Nibhorkar M. E (Structure) Scholar, Civil Engineering Department, G. H. Raisoni College of Engineering

More information

AXIAL LOAD TESTS ON BORED PILES AND PILE GROUPS

AXIAL LOAD TESTS ON BORED PILES AND PILE GROUPS AXIAL LOAD TESTS ON BORED PILES AND PILE GROUPS IN CEMENTED SANDS By Nabil F. Ismael, 1 Member, ASCE ABSTRACT: The behavior of bored pile groups in cemented sands was examined by a field testing program

More information

Dead load (kentledge) A structure over the test pile. Ground anchorage either by tension piles or ground anchors. Bi-directional (Osterberg-cell)

Dead load (kentledge) A structure over the test pile. Ground anchorage either by tension piles or ground anchors. Bi-directional (Osterberg-cell) Introduction Fugro LOADTEST Overview STATIC LOAD TESTING O-cell Bi-directional testing State of the art Dr Melvin England Fugro LOADTEST Static load tests Previous/existing technology Developments O-cell

More information

Pile test at the Shard London Bridge

Pile test at the Shard London Bridge technical paper Pile test at the Shard London Bridge David Beadman, Byrne Looby Partners, Mark Pennington, Balfour Beatty Ground Engineering, Matthew Sharratt, WSP Group Introduction The Shard London Bridge,

More information

HOUSE BUILDING DIGEST

HOUSE BUILDING DIGEST HOUSE BUILDING DIGEST (Construction Specifications-Foundations) Creating Enabling Environment for Affordable Housing for All This is an attempt by BMTPC to provide useful but often ignored information

More information

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY.

Compression load testing straw bale walls. Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY. Compression load testing straw bale walls Peter Walker Dept. Architecture & Civil Engineering University of Bath Bath BA2 7AY May 2004 1. Introduction Over the last 10 years a growing number of loadbearing

More information

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov. 2003 to Mar. 15, 2004.

Zhao et al. 2.2 Experimental Results in Winter Season The analysis given below was based on the data collected from Nov. 2003 to Mar. 15, 2004. Proceedings World Geothermal Congress 2005 Antalya, Turkey, 24-29 April 2005 A Case Study of Ground Source Heat Pump System in China Jun Zhao, Chuanshan Dai, Xinguo Li, Qiang Zhu and Lixin Li College of

More information

Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert

Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert Premkumar M Abstract Experimental investigation of heat transfer and Reynolds number

More information

Life after 30! Innovative investigation and repair of the Overvaal railway tunnel. r a i l w a y s a n d h a r b o u r s PROJECT TEAM

Life after 30! Innovative investigation and repair of the Overvaal railway tunnel. r a i l w a y s a n d h a r b o u r s PROJECT TEAM Text Hannes Gräbe Spoornet (Technology Management) hannesg@spoornet.co.za r a i l w a y s a n d h a r b o u r s Life after 30! Innovative investigation and repair of the Overvaal railway tunnel 1 PROJECT

More information

Treasure s report of 1 st Lizzi Scholarship

Treasure s report of 1 st Lizzi Scholarship Treasure s report of 1 st Lizzi Scholarship IWM2006 in Schrobenhausen, Germany: May 5th, 2006 Shingo MORIMASA Graduate Student, GeoMechanics Group, Toyohashi University of Technology Treasure s Report

More information

A case study of large screw pile groups behaviour

A case study of large screw pile groups behaviour Jongerenforum Geotechniek 5 juni 2015 A case study of large screw pile groups behaviour Alice Manzotti Content of the presentation 2 Introduction General soil conditions at the site Foundation design -

More information

STATIC PILE LOAD TEST MANUAL. GEOTECHNICAL CONTROL PROCEDURE GCP-18 Revision #4

STATIC PILE LOAD TEST MANUAL. GEOTECHNICAL CONTROL PROCEDURE GCP-18 Revision #4 STATIC PILE LOAD TEST MANUAL GEOTECHNICAL CONTROL PROCEDURE GCP-18 Revision #4 AUGUST 2015 GEOTECHNICAL CONTROL PROCEDURE: STATIC PILE LOAD TEST MANUAL GCP-18 Revision #4 STATE OF NEW YORK DEPARTMENT

More information

LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES

LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES Test Procedure for LABORATORY CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES TxDOT Designation: Tex-142-E Effective Date: August 1999 1. SCOPE 1.1 This method is a system for classifying disturbed and

More information

Field tests using an instrumented model pipe pile in sand

Field tests using an instrumented model pipe pile in sand Field tests using an instrumented model pipe pile in sand D. Igoe University College Dublin K. Gavin University College Dublin B. O Kelly Trinity College Dublin Reference: Igoe D., Gavin K., and O'Kelly

More information

Geotechnical Characteristics of Two Different Soils and their Mixture and Relationships between Parameters

Geotechnical Characteristics of Two Different Soils and their Mixture and Relationships between Parameters Geotechnical Characteristics of Two Different Soils and their Mixture and Relationships between Parameters Arpan Laskar Post Graduate Student Civil Engineering Department, National Institute of Technology

More information

DEM modeling of penetration test in static and dynamic conditions

DEM modeling of penetration test in static and dynamic conditions DEM modeling of penetration test in static and dynamic conditions Quoc Anh Tran, Bastien Chevalier, Pierre Breul To cite this version: Quoc Anh Tran, Bastien Chevalier, Pierre Breul. DEM modeling of penetration

More information

CHAPTER 6 WEAR TESTING MEASUREMENT

CHAPTER 6 WEAR TESTING MEASUREMENT 84 CHAPTER 6 WEAR TESTING MEASUREMENT Wear is a process of removal of material from one or both of two solid surfaces in solid state contact. As the wear is a surface removal phenomenon and occurs mostly

More information

EFFECT OF POSITIONING OF RC SHEAR WALLS OF DIFFERENT SHAPES ON SEISMIC PERFORMANCE OF BUILDING RESTING ON SLOPING GROUND

EFFECT OF POSITIONING OF RC SHEAR WALLS OF DIFFERENT SHAPES ON SEISMIC PERFORMANCE OF BUILDING RESTING ON SLOPING GROUND International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 2016, pp. 373 384, Article ID: IJCIET_07_03_038 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3

More information

Finite Element Analysis of Elastic Settlement of Spreadfootings Founded in Soil

Finite Element Analysis of Elastic Settlement of Spreadfootings Founded in Soil Finite Element Analysis of Elastic Settlement of Spreadfootings Founded in Soil Jae H. Chung, Ph.D. Bid Bridge Software Institute t University of Florida, Gainesville, FL, USA Content 1. Background 2.

More information

EFFECT OF NANO-SILICA ON CONCRETE CONTAINING METAKAOLIN

EFFECT OF NANO-SILICA ON CONCRETE CONTAINING METAKAOLIN International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 1, Jan-Feb 2016, pp. 104-112, Article ID: IJCIET_07_01_009 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=1

More information

ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT Description: This work shall consist of furnishing all materials, equipment and labor necessary for conducting an Osterberg Cell (O-Cell) Load

More information

THE EFFECT OF STIRRUPS AND HOOKED STEEL FIBERS INSTEAD ON MOMENT-ROTATION CAPACITY OF BEAM-COLUMN CONNECTIONS

THE EFFECT OF STIRRUPS AND HOOKED STEEL FIBERS INSTEAD ON MOMENT-ROTATION CAPACITY OF BEAM-COLUMN CONNECTIONS THE EFFECT OF STIRRUPS AND HOOKED STEEL FIBERS INSTEAD ON MOMENT-ROTATION CAPACITY OF BEAM-COLUMN CONNECTIONS Assist. Prof. Dr. S. KamilAkın 1, Assist. Prof. Dr. Nail Kara 1, 1 Department of Civil Engineering,

More information

Activity P13: Buoyant Force (Force Sensor)

Activity P13: Buoyant Force (Force Sensor) July 21 Buoyant Force 1 Activity P13: Buoyant Force (Force Sensor) Concept DataStudio ScienceWorkshop (Mac) ScienceWorkshop (Win) Archimedes Principle P13 Buoyant Force.DS P18 Buoyant Force P18_BUOY.SWS

More information

Penetration Tests in a Mold on Regolith Quasi-Analogues at Different Relative Densities

Penetration Tests in a Mold on Regolith Quasi-Analogues at Different Relative Densities Penetration Tests in a Mold on Regolith Quasi-Analogues at Different Relative Densities C. Vrettos 1, A. Becker 2, K. Merz 3, and L. Witte 4 1 Division of Soil Mechanics and Foundation Engineering, Technical

More information

CENTRIFUGAL CASTING. Email: amitjoshi@iitb.ac.in amitjoshi1000@yahoo.ca

CENTRIFUGAL CASTING. Email: amitjoshi@iitb.ac.in amitjoshi1000@yahoo.ca CENTRIFUGAL CASTING Amit M Joshi (B.Engg. Mechanical, A.M.I.Prod.E, A.I.E) Dept. of Metallurgical Engg. & Material Science, Indian Institute of Technology Bombay, India. Email: amitjoshi@iitb.ac.in amitjoshi1000@yahoo.ca

More information

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013 INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 3, 2013 Copyright by the authors - Licensee IPA- Under Creative Commons license 3.0 Research article ISSN 0976 4399 Reliability of

More information

LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code

LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900

More information

Settlement of Shallow Circular Foundations with Structural Skirts Resting on Sand. ÉeôdG Y I~æà ùÿg á«fé ûf G ±Gƒ G e á«ë ùdg ájôfg~dg ~YGƒ dg hõf

Settlement of Shallow Circular Foundations with Structural Skirts Resting on Sand. ÉeôdG Y I~æà ùÿg á«fé ûf G ±Gƒ G e á«ë ùdg ájôfg~dg ~YGƒ dg hõf The Journal of Engineering Research Vol. 4, No. (7) 6 Settlement of Shallow Circular Foundations with Structural Skirts Resting on Sand M.Y. AlAghbari Dept. of Civil and Architectural Engineering, Sultan

More information

Evaluation of Initial Setting Time of Fresh Concrete

Evaluation of Initial Setting Time of Fresh Concrete Evaluation of Initial Setting Time of Fresh Concrete R R C Piyasena, P A T S Premerathne, B T D Perera, S M A Nanayakkara Abstract According to ASTM 403C, initial setting time of concrete is measured based

More information

ANALYSIS FOR BEHAVIOR AND ULTIMATE STRENGTH OF CONCRETE CORBELS WITH HYBRID REINFORCEMENT

ANALYSIS FOR BEHAVIOR AND ULTIMATE STRENGTH OF CONCRETE CORBELS WITH HYBRID REINFORCEMENT International Journal of Civil Engineering and Technology (IJCIET) Volume 6, Issue 10, Oct 2015, pp. 25-35 Article ID: IJCIET_06_10_003 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=6&itype=10

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 Introduction The design and construction of foundations require a good knowledge of the mechanical behaviour of soils and of their spatial variability. Such information can be

More information

Seismic performance evaluation of an existing school building in Turkey

Seismic performance evaluation of an existing school building in Turkey CHALLENGE JOURNAL OF STRUCTURAL MECHANICS 1 (4) (2015) 161 167 Seismic performance evaluation of an existing school building in Turkey Hüseyin Bilgin * Department of Civil Engineering, Epoka University,

More information

Chapter. Restoration of Damaged Structures

Chapter. Restoration of Damaged Structures 5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS International Journal of Civil Engineering and Technology (IJCIET) Volume 6, Issue 11, Nov 215, pp. 1-1, Article ID: IJCIET_6_11_1 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=6&itype=11

More information

LABORATORY MODEL TESTS TO EFFECT OF DENSITY TO FILL MATERIAL ON THE PERFORMANCE OF A MODEL REINFORCED SOIL WALL

LABORATORY MODEL TESTS TO EFFECT OF DENSITY TO FILL MATERIAL ON THE PERFORMANCE OF A MODEL REINFORCED SOIL WALL International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 216, pp. 365 372, Article ID: IJCIET_7_3_37 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3

More information

PILE TESTING SPECIFICATION

PILE TESTING SPECIFICATION PILE TESTING SPECIFICATION 1.0 GENERAL This specification deals with the testing of a pile by the application of an axial load or force. It covers vertical and raking piles tested in compression (i.e.

More information

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE A.Rito Proponte, Lda, Lisbon, Portugal J. Appleton A2P Consult, Lda, Lisbon, Portugal ABSTRACT: The Figueira da Foz Bridge includes a 405 m long cable stayed

More information

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October 2013 5 Pages LABORATORY TESTING SECTION. Method of Test for

Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October 2013 5 Pages LABORATORY TESTING SECTION. Method of Test for Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation 5 Pages LABORATORY TESTING SECTION Method of Test for TIME OF SETTING OF CONCRETE MIXTURES BY PENETRATION RESISTANCE 1.

More information

A COMPREHENSIVE STUDY ON PARTIAL REPLACEMENT OF CEMENT WITH SUGARCANE BAGASSE ASH, RICE HUSK ASH & STONE DUST

A COMPREHENSIVE STUDY ON PARTIAL REPLACEMENT OF CEMENT WITH SUGARCANE BAGASSE ASH, RICE HUSK ASH & STONE DUST International Journal of Civil Engineering and Technology (IJCIET) Volume 7, Issue 3, May June 2016, pp. 163 172, Article ID: IJCIET_07_03_016 Available online at http://www.iaeme.com/ijciet/issues.asp?jtype=ijciet&vtype=7&itype=3

More information

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe TN 5.14 February 2010 Introduction It may be at times necessary, in an aging infrastructure, to rehabilitate drainage and sanitary lines

More information

Method Statement for Static Load Testing (Compression) for Micropiles

Method Statement for Static Load Testing (Compression) for Micropiles Method Statement for Static Load Testing (Compression) for Micropiles 1. INTRODUCTION This vertical compression pile maintained load test is usually carried out to ensure the structural and geotechnical

More information