RANGER. select TIMER MODULE PROGRAMMABLE. The OPERATING AND FITTING INSTRUCTIONS
|
|
- Dominick Reynolds
- 7 years ago
- Views:
Transcription
1 select ELECTRICAL The RANGER PROGRAMMABLE TIMER MODULE OPERATING AND FITTING INSTRUCTIONS GUARANTEE The Select Ranger is guaranteed for five years from date of purchase to be free from defects in materials and workmanship. This only applies if the Select Ranger is used in the correct way. The guarantee is also conditional on the product not having been tampered with, modified or subject to attempted repairs. Your statutory rights as a customer are not affected. If the Select Ranger is faulty please return to place of purchase. UK PATENT No HK PATENT No A Philex Electronic Ltd, Philex House, 110 The Broadway, West Hendon, London NW9 7PP
2 THE SELECT RANGER PROGRAMMABLE TIMER Thank you for purchasing the Select Ranger. A high quality timing system that will allow you a facility that has never previously been available. Ingenious design and foresight has enabled us to produce an innovative product which will allow you to set switches and sockets to a timing device. Please read the following instructions carefully and heed all warnings, especially about electricity. 1. General Features 7 ON and OFF programs per day with 1 minute step 24 hour display mode 7 days/mon-fri/sat-sun/or each day settings pair (ON & OFF) selection 1. 7 days all the same 2. a) Mon-Fri the same b) Sat-Sun the same 3. Individual settings for each day Override programmable countdown timer by a separate key activation (Ranger 2 & 3) ON/OFF/AUTO/ RANDOM/ COUNTDOWN MODE/ SELECTION All separate for each model Summer time setting Manual ON/OFF. For continuous operation Reset Button (resets to zero) 6 keys: DAY, HOUR, MIN, TIME SET, PROG and MODE (Ranger 1) 7 keys: DAY, HOUR, MIN, TIME SET, PROG, MODE and COUNTDOWN (Ranger 2 & 3) 2. Electrical Specifications Rated voltage 250V~/ current 6A (EN60669)m current 13A (EN60730) Timer accuracy to +/-2 sec per day at 25C Operating temp: 0 to 50 degrees C Uses 1 x AAA alkaline non-rechargeable battery (not included). Not suitable for use with rechargeable batteries For continuous operation 3. Contents: Timer Module 2x Main Bracket 2x Bracket extension piece 1x Angle Bracket (can be easily removed for your convenience) Retaining screws (already fitted) + 2 extra short screws 2x extended switch/socket screws 1x one-way connector terminal block 1x adhesive pad Instructions 4. Battery Connection Remove battery cover on front of appliance Place 1 x AAA into compartment ensuring + to right / - to left Replace cover NB: If battery is inserted incorrectly, wait 30 seconds before replacing correctly. By utilising a battery circuit your Select Ranger timer programme is not affected by a power failure. a d e h DAY TIME SET S PGM MO TU WE TH FR SA SU OFF AUTO ON RAND HOUR PROG COUNTDOWN MIN MODE b c f g 5. Keyboard definition a. Day. set day of week toggle output in AUTO/RANDOM/COUNTDOWN MODE b. Hour. Set current time and program time c. Min. Set current time and program time, changes minutes in countdown mode d. Time Set. Set the current time e. Prog. Select and set program f. Mode. Select the operation mode g. Countdown. Activate the countdown timer mode On immersion and professional models only h. Reset 1
3 6. Power Up All segments will be ON for 2 secs after battery insertion Default time: 00:00 Monday All program timers are un-set i.e. : Default operation mode : manual OFF If battery is removed for any reason, wait 30 seconds before re-insertion S PGM MO TU WE TH FR SA SU 00: 00 OFF AUTO ON RAND 7. Display Mode Normal time display Timer Clock displays in day, hour and minute Colon flashes at a rate of 1Hz Clock updates every minute Other Indicator represents output is ON Indicator represents output is OFF MO OFF 00: 00 Countdown timer display On immersion heater and professional models only (Ranger 2 & 3) Timer displays in MINUTE only Other Indicator shows when the timer is setting and flashes when the timer is counting 8. Setting Mode Clock Setting Mode Available in Manual ON, Manual Off and AUTO mode only If setting in Summer Time, read section below Press and continually hold key TIME SET to enter in clock setting mode Colon will become solid Press either HOUR MIN or DAY to set the clock time and day Hold key HOUR MIN or DAY for 2 sec to enter fast advance (continuous turnover will commence) Release key TIME SET will set the clock and exit the clock setting mode Clock second will be set to ZERO once HOUR, MIN or DAY is pressed NB: Don t forget the special Summer Time setting - see section below : PGM Summer Time Setting Mode Available in Manual ON, Manual OFF and AUTO modes only Press TIME SET and PROG simultaneously for 3 seconds to set S indicator ON when activated Clock advances one hour If setting clock during Summer Time, set for one hour early, then advance time using the procedure above Winter Time, follow procedure above to return clock to winter setting 2 75 S WE 0: 45 AUTO
4 Program Setting Mode 1. Available in Manual ON, Manual OFF and AUTO modes only 2. Press PROG to enter setting mode 3. Prg1 will be shown : PGM Press TIME SET to toggle between countdown timer and normal clock display Press COUNTDOWN to exit countdown timer and change to return to auto mode There are up to 7 program modes 5. ON and OFF are designated by the relevant symbols 6. : indicates there are no presets in place 7. Press DAY to all days MON-SUN, MON-FRI, SAT-SUN, individual days, program clear and then repeat 8. Press HOUR, MIN to set the program time (fast advance as previous) 9. Press PROG to Prg1 OFF s program (or next in sequence) 10. To set remaining programs repeat from step Press PROG again to advance the program number 12. Press TIME SET to exit setting mode 13. Auto return to clock if idle for 3 mins Example 1: To set ON Example 2: To set OFF MO TU WE TH FR SA SU PGM 1 06: 30 MO TU WE TH FR SA SU PGM 1 09: 45 Countdown Timer Setting Mode On immersion heater and professional models only (Ranger 2 & 3) Press COUNTDOWN to enter mode Press key MIN within 5 secs to set the countdown timer Clock shows 75 and cycles down in 15 minute segments (75, 60, 45, 30, 15, 1, then back to 75) Countdown timer will activate if no other key is pressed within 5 seconds indicator will flash during countdown Manual Off Mode Press MODE to select MANUAL OFF mode OFF indicator displayed Normal clock display All programs are ignored Output is permanently OFF Allows both Clock setting and Program setting Auto Mode Press MODE to select AUTO indicator ON Normal display clock Press DAY to toggle output Allows both Clock setting and Program setting Program output control is activated NB If there are program time overlapping, the higher program number has the highest priority. PROG OFF always has priority over PROG ON Manual ON Mode Press MODE to select ON indicator displayed Normal clock display All programs are ignored Output is permanently ON Allows both Clock setting and Program setting Random Mode On security lighting and professional models only Press MODE to select RAND indicator ON Normal clock display All programs are ignored Clock setting and Program setting is not possible Random output control is activated Frequency: 4-12 times per day ON period: 5-60 minutes Output is ON when activated 3
5 WARNING: DISCONNECT MAINS POWER PRIOR TO INSTALLATION FITTING INSTRUCTIONS The Select Ranger comes complete with a universal bracket which will allow you to fit it to single or twin switches, also single or twin socket outlets (switched/unswitched). N.B. The Select Ranger should only be fitted to flat surfaces. The Select Ranger can be fitted to the left or right of the switch or socket outlet. The Select Ranger is for FLUSH mounting only. Most domestic sockets and switches are flush mounted. Supplied already assembled for attachment to the right hand side of the switch/socket, it is easily converted for left hand use. To convert the module: 1 1. Remove the two screws in the back of the bracket. 2. Remove the module 2 from the bracket housing. 3. Turn bracket through 180 degrees so that the legs are pointing in the opposite direction. 4. Replace the module into the bracket 3 housing, inserting the two wires from the module through the hole in the bracket housing Replace the two retaining screws through the back of the bracket housing into the screw holes in the module and tighten. IMPORTANT When fitting the Select Ranger to a light switch it should be protected by an in-line fuse. However, as long as your premises are fitted with a fuse box or consumer unit, no additional fuse is required. 5 IMPORTANT - It is recommended that you program the timer before attaching the module to the switch/socket. See programming instructions. A LIGHT SWITCH Not Suitable for 2 Way Switches* When connecting to a two gang switch (2 switches on one plate) attach your Select Ranger to one switch only. 1. After switching off the mains, remove the two screws that hold the switch to the wall. 2. Pull the switch gently away from the wall. DO NOT REMOVE ANY WIRES. 3. Place the module and bracket housing over the open switch box. 4. Loosen screw to mains input (in the back of the switch) without removing any wires. 5. Insert the chosen module live wire into the input and tighten screw to secure. 6. Put the other module wire into the switch output. Follow steps 4 and 5 to complete the procedure. 7. Ensure all wires are secure in relevant ports. 8. Assemble the rest of the bracket (see below) and align with screw holes in the switch box. 9. A double-sided sticky pad is provided to secure the bracket to the wall. 10. Position the switch plate over the bracket aligning the screw holes. Using the extended screws provided, secure the whole assembly to the wall. 11. When the assembly is fully secure you can switch on the mains. 12. The Select Ranger is now ready for use. * A 2 Way switch is defined as being one of two light switches which operate the same light from different locations. LIGHT SWITCH ASSEMBLY 4
6 5 WARNING: DISCONNECT MAINS POWER PRIOR TO INSTALLATION B IMMERSION HEATER SWITCH (Ranger 2) For immersion heater follow instructions for 13 amp sockets. C 13 AMP SOCKETS Single/Twin/Switched/Unswitched NB. For the timer module to operate effectively on your 13 amp socket, it needs to be fitted differently to the module being attached to a light switch. 1. After switching off the mains, remove the two screws holding the socket front plate to the wall. 2. Pull the front plate gently away from the wall. DO NOT REMOVE ANY WIRES YET. 3. Place the module and bracket over the open socket. Identify the LIVE WIRE on the back of the socket and undo the screw holding it in place. 4. Using the connector provided join the LIVE WIRE to the chosen module live wire (see diagram below). Undo screws, place live wire in one end and module wire in the other and tighten screws. LIVE WIRE to socket 5. Insert the other module wire into the LIVE terminal on the back of the socket and tighten the screw. 6. Ensure that all wires are secure. 7. Assemble the rest of the bracket and align with the screw holes in the socket box. 8. Use the double-sided sticky pad provided to secure the bracket to the wall. 9. Position the socket front plate over the bracket aligning the screw holes. Using the extended screws provided secure the whole assembly to the wall. 10. Switch on the mains. 11. The Select Ranger is now ready for use. 12. For the socket to operate normally ensure that the DOUBLE SOCKET ASSEMBLY LIVE WIRE to Timer Module timer module is in the ON mode. SINGLE SOCKET ASSEMBLY 13. When wishing to put the timer programme into OPERATION mode and ensure that the timer module is in AUTO mode and leave the socket switch(es) in the ON position. D ANGLE BRACKET This bracket has been provided to give an improved viewing angle (particularly useful when attaching the module to low mounted sockets). To fit the angle bracket, remove the module from the main bracket (see page 4). Place the angle bracket over the main bracket, ensuring that the lips are fitted over the main bracket. Replace module as before (see page 4). E DIMMER SWITCH One Way only OPTION 1 - Fit as if to a normal light switch. When operating the light through your Select Ranger the light will come on at full intensity. The dimmer switch will operate normally. OPTION 2 - Fit as if to a socket. This will allow you to adjust the setting on the dimmer. NOTE: (Option 2 only) For the dimmer switch to operate normally the Select Ranger must be in the ON mode. To operate the lights with the timed programmes, the Select Ranger must be in the AUTO mode with the dimmer switch on and adjusted to the correct setting NB: NOT SUITABLE FOR FITTING TO SURFACE MOUNTED SWITCHES OR SOCKETS. Surface mounted refers to switches or sockets which are mounted on a pattress (base box) affixed to a wall. As with most industrial/commercial sockets. See diagram. FAULT FINDING 1. If the LCD fails to come on, check that the battery is fitted correctly. 2. If the module fails to operate the timer programme, check for low battery and replace if necessary. 3. If the LCD locks in one position, press the RESET button then follow the setting/programming instructions. IF YOU ARE IN DOUBT ABOUT ANY OF THESE FITTING INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
Fused Spur Time Switch
Fused Spur Time Switch Model No. FST24 24 Hour Timer Model No. FST77 7 Day Timer Installation & Operating Instructions 1. General Information Illuminated screen Sets programmes Sets time and date Reset
More informationAN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
More informationPS42309C INSTRUCTION MANUAL
7-Day Digital Timer Model Number: PS42309C INSTRUCTION MANUAL 7-Day Digital Timer Warranty Details The product is guaranteed to be free from defects in workmanship and parts for a period of 12 months from
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationOwner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable
Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10 Programmable thermostat Thermostat programmable Termostato programable Read and save these instructions. Veuillez lire le mode d
More informationTRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser
FITTING AND OPERATING INSTRUCTIONS FOR DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM General information is given in the users instruction leaflet despatched with the appliance and/or on
More informationOperating instructions for built-in electronic timers with Day and Week programms. Series 884
Operating instructions for built-in electronic timers with Day and Week programms Series 884 Attention: This operating manual is destined for our OEM customers and is intended as a basis for the instruction
More informationEK908FHL - Thermostat for floor heating
EK908FHL - Thermostat for floor heating EK908FHL is a programmable thermostat designed for floor warming application or helping to limit floor temperature. This thermostat can be used for hot water radiant
More informationDAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
More informationOPERATING INSTRUCTIONS
24 HOUR IMMERSION HEATER TIME CONTROLLER Cat. No TS900B OPERATING INSTRUCTIONS TS900B 24 Hour Immersion Heater Time Controller 24 hour programme ring Self-cancelling and Override switch Setting pins Time
More informationCR9971 2 Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use
ROBERTS Sound for Generations CR9971 2 Band Auto Set Dual Alarm Clock Radio Please read this manual before use Contents Contents... 1 Controls...2-5 Switching on... 6 Setting the time manually... 6 Setting
More informationProgrammable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
More informationSET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark
SET1E Electronic timeswitch for heating & hot water Installation & User Instructions Certification Mark Index INDEX Installation Product specification 3 Installation 4-5 Wiring 5-10 Replacement 11-13 User
More informationTABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
More informationMaster Time Clock MTC-200 MTC-400 MTC-600. Users Manual
Master Time Clock MTC-200 MTC-400 MTC-600 Users Manual Toll Free (888)713-0373 Phone (972)987-4408 FAX (877)720-9291 www.midwest-time.com sales@midwest-time.com TABLE OF CONTENTS TOPIC PAGE GENERAL DESCRIPTION
More informationRain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
More informationCR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use
ROBERTS Sound for Generations CR9986 Dual Alarm CD Clock Radio Please read this manual before use Contents Contents... Controls... - Switching on and setting the time... 4 Listening to the radio... 5 Compact
More informationOperating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2
Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2 Heatmiser UK td Tel: +44(0)1254 776343 Primrose House www.heatmiser.co.uk Primrose Street Darwen ancashire BB3 2DE Contents Contents 1 Installation
More informationRADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906
RADIO CONTROLLED DIGITAL CLOCK MODELS 88905 / 88906 QUICK SETUP GUIDE IMPORTANT! INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER BEFORE INSTALLING BATTERIES IN THE RADIO-CONTROLLED CLOCK. ALKALINE BATTERIES
More informationWireless 7 Day Programmable Room Thermostat
Wireless 7 Day Programmable Room Thermostat Cat. No. TRT037 Transmitter Receiver Operating & Installation Instructions What is a programmable room thermostat? an explanation for householders A programmable
More informationRUST ELECTRONICS LTD. Remote Switching Unit RCU-O4
RUST ELECTRONICS LTD Remote Switching Unit RCU-O4 MAINS REMOTE SWITCHING UNIT RCU-O4 The RCU-O4 is a radio remote controlled switching unit that will allow the remote operation of any appropriate electrical
More informationUser Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
More informationTP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions
TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Certification Mark GB Installation and GB Index Index Installation Instructions 3-14 Product Specification
More informationINSTALLATION AND OPERATING INSTRUCTIONS
ddcwp_manual_gb_revisions.ai 10/23/06 Page 1 Date: Station 1 2 3 4 5 6 7 8 CUSTOM WATERING PLAN 3 Program Controller Description Program A Program B Program C Duration Duration Duration DDC WP Series Waterproof
More informationAM / FM Tuner + RDS. Model: TU-101. www.pulse-audio.co.uk
AM / FM Tuner + RDS Model: TU-101 www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels within the product
More informationTime Recorder. User Manual. PDF created with FinePrint pdffactory trial version www.pdffactory.com
Time Recorder User Manual 1 (1) Specifications: 1. Power supply 100, 110, 200, 220, 230 V AC (as designated), 50/60 Hz, single phase. 2. Power consumption Normal 2W (MAX 30W) 3. Standard time signal Quartz
More informationBathroom Cabinet. Installation & User Guide. Illuminated Mirrors. www.illuminated-mirrors.uk.com
Illuminated Mirrors The UK s Largest LED Mirror Supplier to Trade and Retail Installation & User Guide Bathroom Cabinet www.illuminated-mirrors.uk.com Bathroom Cabinet Installation & User Guide Thank you
More informationPROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL
PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL 1 CODES AND OPERATION CODES The factory set Master Code is #1234. This should be changed immediately after installation (see Program 10). The Master
More informationPR-2500 Portable Receiver. Owner s Manual
PR-2500 Portable Receiver Owner s Manual CONTENTS The PR-2500, battery charger, and belt clip. (figure 1) Figure 1 Warning This device complies with Part 15 of the FCC rules, operation of this device is
More informationWIRELESS HOME ALARM SYSTEM (WHA1)
WIRELESS HOME ALARM SYSTEM (WHA1) IMPORTANT : PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS ALARM SYSTEM. SAFETY Please note: Before you start to install this alarm, we
More informationSTERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
More informationIN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
More informationINFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
More informationLUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
More informationManual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
More informationSystem pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611
DT1-IK 2CSM204275R0611 DT1-IK/24V 2CSM204285R0611 DT1-IK/DCF 2CSM204295R0611 DT2-IK 2CSM204325R0611 System pro M GB -1- WEEKLY DIGITAL TIME SWITCH + PROGRAMMING KEY I -11- INTERRUTTORE ORARIO DIGITALE
More informationCAD-05 Kit GSM Auto Dialer. Owner s Manual
CAD-05 Kit GSM Auto Dialer Owner s Manual CAD-05 Kit Manual.indd 1 Warnings: This device complies with Part 15 of the FCC rules, Operation of this device is subject to the following conditions: 1. This
More informationUser Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
More information767 Diagnostic System
767 Diagnostic System 3.5v 767 Wall Transformer Patent Pending Listed to: UL 60601-1 CSA C22.2 No. 601 Thank you for purchasing the Welch Allyn 3.5v 767 Wall Transformer. This manual is meant to provide
More informationOperation Guide 3M-22
Operation Guide 3M-22 TEMP UP Target Temp Time Reset TEMP DOWN Control Panel Heat/Cool Mode Switch Fan Switch Battery Compartment Statement of use: The 3M-22 can be used with - millivolt, 24VAC single
More informationOperating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)
Operating Manual for the Electronic Built-in Interval Timer Micro II (Countdown Timer) Note: This document has been designed for our OEM customers. They can use it as supporting material when creating
More informationYour Simple Guide to Battery. www.firstalertpro.com. Replacement. Customer Care: 1-800-852-0086. www.firstalertpro.
Previous Menu Your Simple Guide to Battery www.firstalertpro.com Replacement p e t s ts ep -by Customer Care: 1-800-852-0086 FA/1565 9/00 www.firstalertpro.com Table of Contents: page Introduction...............................
More informationTHERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260
THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260 STANDARD THERMOSTAT KIT 1.0 KIT CONTENTS Parts included: 1 x Thermostat 1 x Wall plate 2 x Mounting box screws 1 x Floor temperature
More informationFG MOISTURE MONITOR Installation & Operation Manual
FG MOISTURE MONITOR Installation & Operation Manual Issue 3.0 7/20/10 1 Contents SERVICE AND TECHNICAL SUPPORT... 2 INSTALLATION:... 3 MOISTURE SENSOR INSTALLATION:... 3 SENSOR CONNECTOR:... 5 MONITOR
More informationES-LCD User Control SD Card Location
SD Card Location Addendum to Leaflet Number 671415 The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC Checking SD Card for secure location Due to the possibility of movement during transit,
More informationPK5500 v1.1 Installation Instructions
PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on
More informationUser Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:
User Manual Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included: 1: Display Console 1: Control Box 2: Encoder (Wires attached) (Not Shown) 1: 5v Power Supply
More informationAUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL
ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142
More informationCOMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
More informationModel 53603. Owner s Manual. Español - P. 19 Français - P. 39
Model 53603 Owner s Manual Español - P. 19 Français - P. 39 Table of Contents I. Introduction............................ 1 Sample Watering Plan.......................... 1 II. Installation...........................
More informationEBDSPIR-PRM, EBDSPIR-PRM-IP
Product Guide EBDSPIR-PRM, EBDSPIR-PRM-IP Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional
More informationINSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
More informationLCD Display. Function keys. Stand. Adapter socket
433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instructions manual INTRODUCTION: Congratulations on purchasing this innovative 433MHz Projection alarm clock which displays indoor temperature and humidity
More informationMini Timer Owner's Manual. Model MT13A
Mini Timer Owner's Manual Model MT13A Contents Introduction...3 Quick Tour...5 How to program a timed event...6 Special programming buttons...6 Setting up the Mini Timer...7 Setting the clock...7 Controlling
More informationwww.ringautomotive.co.uk Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A
SmartChargePro7 RSCPR7-12v, 7A SmartChargePro10 RSCPR10-12v, 10A SmartChargePro15 RSCPR15-12v, 15A SmartChargePro25 RSCPR25-12v, 2 / 6 / 12 / 25A SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A SmartChargePro50
More informationCHAPTER 11: Flip Flops
CHAPTER 11: Flip Flops In this chapter, you will be building the part of the circuit that controls the command sequencing. The required circuit must operate the counter and the memory chip. When the teach
More informationT7400. Guest Paging System. Long Range Systems, Inc. 9855 Chartwell Dr., Dallas, TX 75243 1-800-437-4996. V6.21 and later
T7400 Guest Paging System By: Long Range Systems, Inc. 9855 Chartwell Dr., Dallas, TX 75243 1-800-437-4996 V6.21 and later User Manual With Installation, Warranty and Service Information Rev 4 January
More informationVroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
More informationCM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM702 PROGRAMMABLE THERMOSTAT FEATURES Attractive slim, modern styling makes it ideal for location in any type of home. 24-hour heating program. Up to 4 daily independent time and temperature level changes
More informationGround Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
More informationHow To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
More informationAC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
More informationWIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
More informationSecure Keypads for access control
torm Secure Keypads for access control Strike Master Read this manual carefully before attempting to install, program or operate the STORM AXS Strike Master Keypad. After installation the Command Summary
More informationOperating instructions IV / 2007
General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation
More informationInstallation & User Instructions
103 electro-mechanical 24 hour timeswitch for controlling hot water and heating Installation & User Instructions including Factory Replacement Units (FRU) Certification Mark This product complies with
More informationIMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
More informationUser s Guide. Sprinkler Timer with Computer Programming Option. ECXTRA Features
User s Guide Sprinkler Timer with Computer Programming Option ECXTRA Features OUTDOOR MODEL A B C ON MANUAL NEXT START OFF ON MANUAL START OFF INDOOR MODEL NEXT Easily expandable to 10 Zones (Indoor model)
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationSETTING UP YOUR 6000 SERIES TIME RECORDER
INTRODUCTION The Pyramid 6000 Series Time Recorder is an electronic time recorder designed to make payroll processing easier and more efficient. The 6000 series will meet your business needs whether your
More informationWireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
More informationAlarm Clock USER GUIDE
Alarm Clock USER GUIDE Jazwares, Inc. 2010 1 CONTENTS Please read the instructions along with the alarm clock carefully before you use it, so that you can operate it conveniently. WELCOME, Safety Tips
More informationH203D 中文 GB Version 1
H203D 中 GB文 Version 1 Contents Installing batteries... 4 Using the AC adapter (not supplied)... 5 Setting the clock... 6-7 Updating your radio - DAB... 8 Selecting a station - DAB... 9 Secondary services
More informationPSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA www.luxproproducts.com
PSPA711a LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS 52070 1 COMPATIBILITY...................................... 2 2 FEATURES............................................ 2 3 ELECTRICAL RATINGS................................
More informationit500 Internet Thermostat INSTALLER MANUAL
it500 Internet Thermostat INSTALLER MANUAL 1. Product compliance & safety information These instructions are applicable to the SALUS Controls model stated on the front cover of this manual only, and must
More informationService Guide. Gateway M275
Service Guide Gateway M275 Contents Replacing Gateway M275 Components.................................... 1 Identifying the convertible tablet PC model...................................... 2 Identifying
More informationWater Tank Level Monitor
Water Tank Level Monitor INSTRUCTION MANUAL MODEL NO: WTL001 Table of Contents 1. INTRODUCTION... 2 1.1 Package Contents... 2 1.2 Features... 2 2. INSTALLATION... 3 2.1 Water Tank Sensor Battery Installs...
More informationUser's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
More informationENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationELECTRIC POSITION for electric heat, then confirm with Fan Test below.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
More informationEM6556 e-domotica Mini Switch
EM6556 e-domotica Mini Switch EM6556 e-domotica Mini Switch 2 ENGLISH Table of contents 1.0 Introduction...2 1.1 Functions and features...2 1.2 Packing contents...2 2.0 Using the mini switch...3 2.1 Use
More informationExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
More informationHP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in
HP Pavilion All-in-One MS200 series PC *579907-001* *579907-001* Printed in Upgrading and Servicing Guide Replacing a Wireless Keyboard or Mouse...2 Before You Begin... 2 Replacing the Keyboard or Mouse...
More informationATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE
LCD1 display LCD2 display ATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE INTRODUCTION: Congratulations on purchasing this state-of-the-art Skyscan Atomic Clock as an example of superior design and engineering.
More informationWIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
More informationHWS100 Wireless Home Security System
4902000 HWS100 Wireless Home Security System Owner s Manual WARNING: Security system devices cannot compensate for loss of life or property. Company is not responsible for any loss or intrusion. CONTENTS
More informationwww.corbyofwindsor.com
DIGITAL SAFE COI0025_V2_121015 USE & CARE MANUAL www.corbyofwindsor.com SECTION 01 These notes must be read before use These instructions are for your safety. Please read through them thoroughly before
More informationOPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES
OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES 1 TABLE OF CONTENTS POWER SUPPLY... 3 SPECIFICATIONS... 3 MAINATENANCE AND GENERAL CARE........
More informationOwner s Guide. ca6554
PROFESSIONAL SERIES Owner s Guide For Models: ca6554 Deluxe Vehicle Security and Remote Start System with 2 Way Confirming LCD Remote Control IMPORTANT NOTE: The operation of the Security and Convenience
More informationDisassembly Procedure
Chapter 2 Disassembly Procedure Please follow the information provided in this section to perform the complete disassembly procedure of the Eee PC 4G (701). Be sure to use proper tools described before.
More informationWireless Home Security Alarm System AM 500
Wireless Home Security Alarm System AM 500 12 MONTH GUARANTEE Installation & Operating Instructions INTRODUCTION The AM500 is a simple self-contained alarm system. It protects the home by sounding a siren
More informationAlpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
More informationProduct Information Sheet UH36 Hi Pot Tester
Product Information Sheet UH36 ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: info@etl-prueftechnik.de Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet: www.etl-prueftechnik.de
More informationInstallation Instructions
TP-PRH-A, TP-NRH-A Performance Series Edge Thermidistat Control Installation Instructions Programmable Control A07049 A07048 Non Programmable Control Designed and Assembled in the USA. NOTE: Read the entire
More informationAlarm Security Kit - NVR
Alarm Security Kit - NVR EN The alarm configuration menu (see above right screenshot) allows you to configure and change settings for the PIR movement sensors, window/door sensors, remote controls (key
More informationGB/DAS User Instruction
GB/DAS User Instruction devireg 540/550 Table of contents Introduction 3 Introducing devireg 540/550 4 How to use your deviheat heating system 6 Daily operation 7 Setting the clock & day 10 Timer programming
More information5W LED Energy Saver PIR Bulkhead
5W LED Energy Saver PIR Bulkhead Model: LED88PIR Black I n s t a l l a t i o n & Ope r a t i n g I n s t r u c t i o n s 1. General information: The unit utilises passive infrared technology to detect
More informationUSER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
More informationPlease read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3