FARIDABAD CIRCLE ABSTRACT ( SCOPE OF WORK & ESTIMATED COST FOR FARIDABAD CIRCLE )

Size: px
Start display at page:

Download "FARIDABAD CIRCLE ABSTRACT ( SCOPE OF WORK & ESTIMATED COST FOR FARIDABAD CIRCLE )"

Transcription

1 FARIDABAD CIRCLE ABSTRACT ( SCOPE OF WORK & ESTIMATED COST FOR FARIDABAD CIRCLE ) Sr.No. Descriptions Quantity Amount (in Rs.) 1 11 kv Line : New Feeder/ Feeder Bifurcation Kms UG Cable Kms Installation of Distribution Transformer I Proposed 100 KVA T/F Nos II Proposed 00 KVA T/F Nos LT Line : New Feeder/ Feeder Bifurcation Kms Metering Grand Nos

2 H(1). Estimate for 11 KV HT Line (5 Kms.) with ACSR Conductor 100mm with span 0 meters and double earth wire with guards P&D approved rate for the period to or latest PO rate issued by P&D Cost of per unit for overhead charges on P&D rate (in %) overhead charges (In Rs) supply and (In Rs.) =X9 11=X7 1= Support for 11 KV overhead line as per technical specification, approved drawings and scope of work 1.01 PCC Pole 11 Mtr. Long. 8 No. X 5 km = 9660 No. No % Pre-fabricated Hot dip Galvanised steel items like V cross arm, top clamp, DC cross arm, bracket, clamps, cross bracings, bracings strain plate, guarding channels, back clamp, transformer mounting structure etc made of Galavnised Channels (100x50x6mm), Galavnised angle (65x65x6mm), Galvanised flats (65x8mm) of given sizes for over head structures as per technical specification, approved drawings and scope of work KV Line Top Bracket/Hamper (1 No.) -.65 Kg. X Nos. X 5 Kms. = Kg KV Line V Cross Arm (1 No.) Kg. X Nos. X 5 Kms. = Kg..0 GalvanisedS Channel (X-arm) 100x50x6mm-00 mm for H-Pole (1 No.) Kg. X 6 Nos. X 5 Kms. = Kg. MT % Galvanised Angle Iron 50x50x6mm-00 mm for earthing (1 No.) Kg. X Nos. X 5 Kms. = Kg..05 Galvanised Channel 100x50x6mm-1600 mm for earthing (1 No.) Kg. X Nos. X 5 Kms. = Kg..06 Galvanised Angle 50x50x6mm-860 mm for Bracing H-Pole (1 No.) Kg. X 6 Nos. X 5 Kms. = Kg..07 Galvanised Angle 50x50x6mm-100 mm for belting (1 No.) - 6. Kg. X 6 Nos. X 5 Kms. = 101 Kg..08 Half Clamp (1 No.) Kg. X 56 Nos. X 5 Kms. = Kg..09 Full Clamp (1 No.) -.5 Kg. X 18 Nos. X 5 Kms. = 18.5 Kg..01 GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. GI Nuts, Bolts & Washer off sizes - 8 Kg. X 5 Kms. = Kg. Kg % Hot dip Galvanised Eye Screw Bolt 9"x5/8" (1 No.) Kg. X 56 Nos. X 5 Kms. = Kg. Kg & RGGVY % Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator ( Nos.), anchor plate (00x00x6), nut bolts, Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/.15 mm dia GI stranded wire complete as per technical specification, approved No & % drawings and scope of work. 18. No. X 5 Km = 610 No Insulator and hardware as per technical specification, approved drawings and scope of work. 11 KV polymeric Disc insulator 5 KN along with suitable hardware fittings 18 No. X 5 Km = 610 No. No % KV Polymeric Pin Insulators 75 No. X 5 Km = 5875 No. No % Earthing arrangement as per technical specificatons, approved drawings and scope of work. 0 mm dia., 000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and other accessories complete 1 No. X 5 Km = 5 No. Set % Spike Earthing 0mm solid Rod. 9 No. X 5 Km = 105 No. No. 105 JVVL rates % SWG GI wire, GI nuts, bolts & washers for earthing and guarding 60 Kg. X 5 Km. = Kg. Kg % PG Clamps for 0/50/80/100 mm 18 No. X 5 km = 610 No. No % Barbed Wire 8 Kg. X 5 Km= Kg. Kg % Danger Plate (Enamelled with Clamp) 8 No. X 5 Km = 9660 No. No % Phase Indication Plates for each phase set of (On H-Pole & Pole) Set. X 5 Km = 105 Set Set % ACSR / AAAC Conductor 100mm.06 Km X 5 Km = Km. Km % LV Line overhead crossing and underground railway crossing ensuring statutory clearances KV LINE FOR UNDER GROUND RAILWAY CROSSING BY Nos (INCLUDING ONE SPARE) Cx00 Sqmm XLPE Armoured Cable (0. km each) USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, Nos GI -Meters LONG PIPE EARTHING, 6 SWG GI WIRES, CABLE MARKERS, BI METALLICK Set. 1 Calculated % CLAMPS, JUMPERING WITH 11 KV ARIAL BUNCHED CABLES 00 sqmm dia(10 mtr) etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK Note: -. The word "IPDS" shall be engraved on all major materials viz Poles, Power & Distribution Transformers (all type) Cables, Energy meter etc. supplied under this NIT.

3 K(i). Sr. No. Estimate for New HT Line (5.5 Km) with XlPE C 00 mm sq =X9 11=X7 1=10+11 /C 00 mm sq. 11 kv XLPE cable 1.06 Km X 5.5 Km = Km 1 KM % Description Qty Ref. End termination kit for /C 00 sq. mm Cable no. X 5.5 Km = 91 No. P&D approved rate for the period to or latest PO rate issued by P&D Cost of per unit charges on P&D rate for for supply and overhead charges (In Rs) No % /C 00mm Heat shrinkable cable straight through Joint. No. X 5.5 Km = 17 No. HDPE Pipe 160mm 1.06 Km X 5.5 Km = Km (HDPE Pipe thickness should be between 7.7 mm to 8.7 mm) Nos % KM Market Rate % Note: -. The word "IPDS" shall be engraved on all major materials viz Poles, Power & Distribution Transformers (all type) Cables, Energy meter etc. supplied under this NIT. Prepared By Checked by Verified by Pre-Audited by AE/P&D Xen/P&D SE/P&D

4 M (I). Urban Electrification Works in Faridabad Circle in Haryana under IPDS Estimate for Pole Mounting Sub-stations with 100 KVA (50 Nos.) Transformers ( Ph) P&D approved rate for the period to or latest PO rate issued by P&D Cost of per unit charges on P&D rate =X9 11=X7 1= DTR Substation Supports as per technical specification, approved drawings and scope of work PCC Pole 11 Mtr. Long. No. X 50 No. = 500 No. No % Pre-fabricated Hot dip Galvanised steel items like DC cross arm (100x50x6 mm), back clamps (65x8 mm), pole clamp (65x8 mm), DO mounting channel (100x50x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work..01 Galvanised Channel 100x50x6mm-00 mm (1 No.) Kg. X Nos. X 50 Nos. = 8690 Kg..0 Galvanised Angle Iron 50x50x6mm-00 mm for earthing (1 No.) Kg. X 1 No. X 50 Nos.= 700 Kg. MT % Galvanised Channel 75x0x6mm-00 mm (1 No.) Kg. X Nos. X 50 Nos.= Kg..0 Transformer Platform Set Kg. X 1 No. X 50 Nos.= Kg..05 Half Clamp (1 No.) Kg. X 1 Nos. X 50 Nos.= 515 Kg..06 Full Clamp (1 No.) -.5 Kg. X Nos. X 50 Nos.= 5 Kg. GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. 1 Kg. X 50 No. = Kg. Kg % for material overhead charges for supply and Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator ( Nos.), anchor plate (00x00x6mm), nut bolts, Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work. No. X 50 No. = 1000 No. No & % Polymer Insulators with hardware fittings, hardware etc as required as per technical specification, approved drawings KV, Disc Insulator (5 KN Tounge & Clevis type) with suitable hardware fittings No. X 50 No. = 750 No. No % KV Pin Insulators with hardware fittings 6 No X 50 No. = 1500 No. No % Outdoor mounting type Distribution box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, dust and moisture vermin, weather proof with degree of protection with suitable bus bars, earthing bus, earthing terminals, box illumination, front door operated with proper locking arrangement, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware as per scope of the work, technical specifications and approved drawings suitable for following transformer: 6.01 Ph 100 KVA Transformer having 00 A TPN isolator, 160A HRC fuse (incomer) and 6 Nos. 90 A SP MCCB (outgoing) 1 No. X 50 No. = 50 No. No % KV Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work. No. X 50 No. = 750 No. 11 kv, -ph, 00 A, Pin type, Vertical Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings 1 No. X 50 No. = 50 No. Nos pipe earthing using 0mm dia GI pipe 000 mm long, as per IS 1161, making earth grid using 50x6mm GI Flat and riser as per scope of work of Distribution Transformer Substations, approved drawings and technical specifications, 1 Set. X 50 No. = 50 Set No % No % Set % ACSR Conductor 80mm (or equivalent AAAC conductor) for jumpering including PG Clamps, bi- metallic connectors, hardware etc as per technical specifications, approved drawings and scope of works PG Clamps for 0/50/80/100 mm No. X 50 No. = 750 No. No % ACSR Conductor 80mm (or equivalent AAAC conductor) for jumpering Meter X 50 No. = 5500 Meter Km % Barbed Wire kg. X 50 Nos.= 500 Kg. Kg % Danger Plate (with Clamp) No. X 50 No. = 500 No. No % Phase Indication Plates for each phase set of (On H-Pole & Pole) 1 Set X 50 No. = 50 Set Set % LT PVC.5Cx10mm Meter X 50 No. = 8000 Meter Km % KVA, 11/0. KV-50V, three phase, oil emmersed, naturally cooled, Al. wound out-door type distribution transformer with CSP (Completely Self protected) feature with thermal based MCCB, and the losses confirming to star rating of B.E.E and confirming latest technical specification and relevant ISS with latest amendments. 1 No. X 50 No. = 50 No. No % Note:. The word "IPDS" shall be engraved on all major materials viz Poles, Power & Distribution Transformers (all type) Cables, Energy meter etc. supplied under this NIT.

5 M (II). Estimate for Pole Mounting Sub-stations with 00 KVA ( 575 Nos.) Transformers ( Ph) P&D approved rate Cost of per unit for for the period to or latest PO rate overhead charges on issued by P&D P&D rate overhead charges supply and =X9 11=X7 1= DTR Substation Supports as per technical specification, approved drawings and scope of work PCC Pole 11 Mtr. Long. No. X 575 No. = 1150 No. No % Pre-fabricated Hot dip Galvanised steel items like DC cross arm (100x50x6 mm), back clamps (65x8 mm), pole clamp (65x8 mm), DO mounting channel (100x50x6 mm), transformer mounting channel (100x50x6 mm), transformer clamping set (50x50x6 mm), transformer belting set ( 50x50x6 mm) as per technical specification, approved drawings and scope of work..01 Galvanised Channel 100x50x6mm-00 mm (1 No.) Kg. X Nos. X 575 Nos. = Kg..0 Galvanised Angle Iron 50x50x6mm-00 mm for earthing (1 No.) Kg. X 1 No. X 575 Nos.= 610 Kg..0 Galvanised Channel 75x0x6mm-00 mm (1 No.) Kg. X Nos. X 575 Nos.= Kg..0 Transformer Platform Set Kg. X 1 No. X 575 Nos.= Kg..05 Half Clamp (1 No.) Kg. X 1 Nos. X 575 Nos.= Kg..06 Full Clamp (1 No.) -.5 Kg. X Nos. X 575 Nos.= Kg. GI Nuts, Bolts with Washers as per technical specification, approved drawings and scope of work. 1 Kg. X 575 No. = 6900 Kg. Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator ( Nos.), anchor plate (00x00x6mm), nut bolts, Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work. No. X 575 No. = 00 No. MT Kg % No & % % Polymer Insulators with hardware fittings, hardware etc as required as per technical specification, approved drawings 11 KV, Disc Insulator (5 KN Tounge & Clevis type) with suitable hardware fittings No. X 575 No. = 175 No. No % KV Pin Insulators with hardware fittings 6 No. X 575 No. = 50 No. No % Outdoor mounting type Distribution box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, dust and moisture vermin, weather proof with degree of protection with suitable bus bars, earthing bus, earthing terminals, box illumination, front door operated with proper locking arrangement, lugs, mounting channel frame, internal wiring with FRLS cables, danger plate, numbering, back clamps, hardware as per scope of the work, technical specifications and approved drawings suitable for following transformer: Ph 00 KVA Transformer having 600 A TPN isolator, 15 A HRC fuse (incomer) and 9 Nos. 10 A SP MCCB (outgoing) 1 No. X 575 No. = 575 No. 9 KV Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work. No. X 575 No. = 175 No. 11 kv, -ph, 00 A, Pin type, Vertical Mounting type, Gang Operated, AB Switch along with Support Insulators, Base Channel, down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings. 1 No. X 575 No. = 575 No. Nos pipe earthing using 0mm dia GI pipe 000 mm long, as per IS 1161, making earth grid using 50x6mm GI Flat and riser as per scope of work of Distribution Transformer Substations, approved drawings and technical specifications, 1 Set. X 575 No. = 575 Set ACSR Conductor 80mm (or equivalent AAAC conductor) for jumpering including PG Clamps, bi- metallic connectors, hardware etc as per technical specifications, approved drawings and scope of works. No % No % No % Set % PG Clamps for 0/50/80/100 mm No. X 575 no. = 175 No. No % ACSR Conductor 80mm (or equivalent AAAC conductor) for jumpering Meter X 575 No. = 1650 Meter Km % Barbed Wire kg. X 575 Nos.= Kg. Kg % Danger Plate (with Clamp) No. X 575 No. = 1150 No. No % Phase Indication Plates for each phase set of (On H-Pole & Pole) 1 Set. X 575 No. = 575 Set. Set % LT PVC.5Cx185mm Meter X 575 No. = 1800 Meter Km % KVA, 11/0. KV-50V, three phase, oil emmersed, naturally cooled, Al. wound out-door type distribution transformer with CSP (Completely Self protected) feature with thermal based MCCB, and the lasses confirming to star rating of B.E.E and confirming latest technical specification and relevant ISS with latest amendments. 1 No. X 575 No. = 575 No. No % Note:. The word "IPDS" shall be engraved on all major materials viz Poles, Power & Distribution Transformers (all type) Cables, Energy meter etc. supplied under this NIT.

6 O(1). Estimate for New LT Overhead Line ( Kms.) with ACSR Conductor 100mm P&D approved rate for the period to or latest PO rate issued by P&D Cost of per unit for overhead charges on P&D rate overhead charges for supply and =X9 11=X7 1= New LT Overhead with 100 mm ACSR conductor using additional supports matching with length and type of existing support as per technical specifications, scope of works and approved drawings 1.01 PCC Pole 09 Mtr. Long. 9 No. X Km. = 161 No. No % New LT Line using New Galvanised Stay Set with anchor plate (00x00x6mm), 50x8mm stay clamp, Stay guy insulator, nut bolts, Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/.15 mm Dia GI stranded wire etc as required as per technical specification, approved drawings and scope of work. 10 No. X Km = 5567 No. No & % New LT Line using New Earthing as per approved drawings, technical specifications and scope of work.01 0 mm dia., 000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and other accessories complete 1 No. X Km. = 557 No. Set % GI Earthing spike made of 0mm solid Rod 6 No. X Km = 0 No. No. 0 JVVL rate % SWG GI wire, GI nuts, bolts & washers for earthing and guarding 60 Kg. X Km. = Kg. Kg % GI nuts, bolts & washers 5Kg. X Km. = Kg. Kg % D-Straps 100 No. X Km. = No. No % LT Insulator 150 No. X Km. = 850 No. No % Guy insulator 10 No. X KM. = 5567 No. No % ACSR Conductor 100 mm.08 Km. X Km. = Km Km % Note: -. The word "IPDS" shall be engraved on all major materials viz Poles, Power & Distribution Transformers (all type) Cables, Energy meter etc. supplied under this NIT. Prepared By Checked by Verified by Pre-Audited by AE/P&D Xen/P&D SE/P&D

7 S. Estimate for Release of Connection to Un-meterd consumer, Replacement of defective / Electro-Mechanical meters of 0000 nos. (1-Ph m P&D approved rate for the period to or latest PO rate issued by P&D Cost of per unit charges on P&D rate Estimated cost for charges Estimated cost for supply and =X9 11=X7 1= Single phase meters for releasing connection to existing unmetered Consumers, replacement of Defective/electromechanical meters. 1 No. X 0000 No. = 0000 No. Nos % LT PVC Cable C 10 mm 15 Meter X 0000 No. = Meter Km % Polycarbonate Weather Proof Outdoor Type Meter cover Boxes for single phase meters with Zinc plated Clamps as Nigam's Tech. Spec. 1 No. X 0000 No. = 0000 No. Nos % Note:. The word "IPDS" shall be engraved on all major materials viz Poles, Power & Distribution Transformers (all type) Cables, Energy meter etc. supplied under this NIT.. All dismentled items/materials shall be returned to the nearest DHBVN store through concerned JE/OP without any value. Prepared By Checked by Verified by Pre-Audited by AE/P&D Xen/P&D SE/P&D

UTTAR PRADESH ELECTRICITY REGULATORY COMMISSION

UTTAR PRADESH ELECTRICITY REGULATORY COMMISSION UTTAR PRADESH ELECTRICITY REGULATORY COMMISSION COST DATA BOOK FOR RECOVERY OF EXPENSES & OTHER CHARGES FROM PROSPECTIVE CONSUMERS FOR TAKING ELECTRIC SUPPLY (APPLICABLE TO ALL DISTRIBUTION LICENSEES IN

More information

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST ANNEXURE I Sl.No. Description for BHEL Requirement Offered Deviation Scope of supply, erection and commissioning: 1 The scope of this specification covers

More information

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before

More information

DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: -

DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - PROPOSED KISUMU HOUSING 3 BEDROOM-TYPE 1 ELECTRICAL INSTALLATION -SITE 01 DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: - 1.0 Final sub-circuit from Consumer Unit to lighting

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS 1. Standards BOS Item / System I ii iii TECHNICAL SPECIFICATIONS Applicable BIS /Equivalent IEC Standards / Applicable MNRE Specifications Standard Description Standard Number Crystalline Silicon Terrestrial

More information

MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade

MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade MAHARSHI DAYANAND UNIVERSITY ROHTAK (A State University established under Haryana Act No. 25 of 1975) NAAC accredited A Grade NOTICE INVITING TENDER Sealed tenders on item basis are invited on behalf of

More information

Schedule-4(A3) Page 1 of 5. Specification No.: JPL/KWTL/A3 (Package-A3) To: Bidder's Name & Address

Schedule-4(A3) Page 1 of 5. Specification No.: JPL/KWTL/A3 (Package-A3) To: Bidder's Name & Address Specification : JPL/KWTL/A3 (Package-A3) Page 1 of 5 Tower Package (Package-A3) for 400 kv D/C (Quad Bundle) Karcham Wangtoo Abdullapur Line Part III associated with Karcham Wangtoo HEP Transmission System

More information

Please check with your local inspection authority for any additional requirements before installation.

Please check with your local inspection authority for any additional requirements before installation. Specifications for Residential Overhead Electric Service Installation This brochure addresses most typical residential overhead service installations. Variances for the following specifications must be

More information

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI TENDER CLARIFICATIONS- no 3 dated 3rd Oct 13 issued in response

More information

TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT

TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT TECHNICAL SPECIFICATION FOR HIGH MAST LIGHTING SYSTEM, 20 MTRS HEIGHT Annexure A Sl.No. Description 1 Scope: The scope cover the design, manufacturing, supply and delivery at GCF Jabalpur on FOR basis

More information

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad PLEASE MARK TICK ON LEFT BOX WHICH EQUIPMENT YOU HAVE QUOTED PROPOSAL BASED ON CHINESE EQUIPMENT

More information

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS

A product made in Australia. Insulated Conductor Rail ACTIV-8 PLUS A product made in Australia Insulated Conductor Rail ACTIV-8 PLUS ACTIV-8 PLUS The Industry Standard in Conductor Rails ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It

More information

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Requirements for the Attachment of Communication Cable Facilities on PPL Poles Page 99 of 137 Requirements for the Attachment of Communication Cable Facilities on Replaces: URS-3002 URS-3004 URS-101C-304 A-157649 Page 100 of 137 Reference Notes for Drawings: General 1. The term communication

More information

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION

INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION INDUSTRIAL AND COMMERCIAL SERVICE TRANSFORMER & METERING INSTALLATION SPECIFICATION February 2013 NOTE: If conflict exists between St. Thomas Energy s Conditions of Service and this document, the Conditions

More information

About our Chairman cum- Managing Director

About our Chairman cum- Managing Director INTEGRATED GROUP Complete Range of Power Transmission and Distribution Equipments & Head office- SO 2-5, Second Floor, Amarjyoti Palace, Lokmat Square, Wardha Road, Nagpur-440012 Group E-mail ID : enquiry@integratedgroup.asia

More information

UGVCL/SP/591/11KV HT AB CABLE

UGVCL/SP/591/11KV HT AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched

More information

ACTIV-8 PLUS Insulated Conductor Bar

ACTIV-8 PLUS Insulated Conductor Bar ACTIV-8 PLUS Insulated Conductor Bar A product made in Australia www.conductix.com.au ACTIV-8 PLUS ACTIV-8 is the most widely used and stocked conductor rail in use in Australia. It was designed by Conductix

More information

Network Standard Advice No. 1420C 9/6/2011

Network Standard Advice No. 1420C 9/6/2011 Network Standard Advice No. 1420C 9/6/2011 TO: Customers, Service Providers and Ausgrid Staff. Advisory Note on Changes to the Use of 11kV Cable Types. Introduction This Network Standard Advice (NSA) provides

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING

TS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

ANTENNA PARTS CATALOG

ANTENNA PARTS CATALOG ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine

More information

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless

More information

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

EARTHING AND BONDING AT SECONDARY SUBSTATIONS DISTRIBUTION CONSTRUCTION MANUAL SECTION 4 - SUBSTATIONS ISSUE B SEPT 1996 4.4.4 EARTHING AND BONDING AT SECONDARY SUBSTATIONS 1 SCOPE This section of the Distribution Construction Manual lays down the

More information

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY PART- IV - ELECTRIC WORK FOR BRANCH Supply, installation, testing and commissioning of following point wiring as per the specifications and drawings. The unit rate for the switch board and further to point

More information

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM

More information

Schedule of Quantities

Schedule of Quantities CIVIL WORK (A) 1 Providing and fixing corrugated galvanised iron sheets of 20 B.W.G. for roofing with wind ties including fastening with galvanised iron screw and bolts and lead and bitumen washers as

More information

CDGRD-10. Grounding. Solutions For Comm/Data Applications

CDGRD-10. Grounding. Solutions For Comm/Data Applications CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering

More information

MAST ARMS & POLES. Ornamental Pole Top & Bases

MAST ARMS & POLES. Ornamental Pole Top & Bases Ornamental Pole Top & Bases Pelco s decorative pole top and bases help make the traffic signal aesthetically pleasing to the eye. Available for various pole diameters and multiple finish options. Ornamental

More information

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR

TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR TECHNICAL SPECIFICATION FOR ELECTRICAL WIRING / PANELS / SWITCH GEAR 1.0 GENERAL REQUIREMENTS The installation shall generally be carried out in conforming with the requirements of the Indian Electricity

More information

TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC)

TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) Prepared by Committee for Technology Assessment and Analyzing the installation of Solar Water Heater Systems in Government

More information

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP

More information

ScottishPower Distribution Cables & Equipment. Metal Theft

ScottishPower Distribution Cables & Equipment. Metal Theft ScottishPower Distribution Cables & Equipment Metal Theft April 2012 As an aid to deterring to metal theft this booklet has been put together to help identify the types of utility power cables and associated

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

TECHNICAL SPECIFICATION FOR 200, 315 & 630 KVA, 11/0.433 KV DRY-TYPE (VPI) DISTRIBUTION TRANSFORMERS (INDOOR AND OUTDOOR)

TECHNICAL SPECIFICATION FOR 200, 315 & 630 KVA, 11/0.433 KV DRY-TYPE (VPI) DISTRIBUTION TRANSFORMERS (INDOOR AND OUTDOOR) TECHNICAL SPECIFICATION FOR 200, 315 & 630 KVA, 11/0.433 KV DRY-TYPE (VPI) DISTRIBUTION TRANSFORMERS (INDOOR AND OUTDOOR) (SPECIFICATION NO. DIST/MM-II/03/2005) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION

More information

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.

More information

Nordson Automatic Spray Gun Support Kits

Nordson Automatic Spray Gun Support Kits Nordson Automatic Spray Gun Support Kits Customer Product Manual Issued / For parts and technical support, call the Finishing Customer Support Center at (800) -99. This document is subject to change without

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

TARIFF CODE and updates standard

TARIFF CODE and updates standard TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of

More information

Boiler Plan II Table of Contents

Boiler Plan II Table of Contents Cover Page Table Of Contents Introduction Parts List Additional Materials Assembly instructions Drawings 1-15 Boiler Plan II Table of Contents Introduction This will be a very rewarding project, if you

More information

DELHI METRO RAIL CORPORATION LIMITED. (A Joint Venture of Govt. of India & GNCTD) MASS RAPID TRANSPORT SYSTEM PHASE III. Contract: - CE -16 VOLUME-6

DELHI METRO RAIL CORPORATION LIMITED. (A Joint Venture of Govt. of India & GNCTD) MASS RAPID TRANSPORT SYSTEM PHASE III. Contract: - CE -16 VOLUME-6 DELHI METRO RAIL CORPORATION LIMITED (A Joint Venture of Govt. of India & GNCTD) MASS RAPID TRANSPORT SYSTEM PHASE III TURNKEY PROJECT OF DESIGN, SUPPLY, LAYING, JOINTING, TESTING AND COMMISSIONING OF

More information

Electrical Service Guidelines

Electrical Service Guidelines Electrical Service Guidelines Middle Tennessee Electric Membership Corporation Revised: May 23, 2013 MTEMC's Electrical Guidelines TABLE OF CONTENTS Right-of-Way Clearance Guide 3 MTEMC Requirements 4

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

When power interruptions happen.

When power interruptions happen. When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage

More information

POWER WAVE 455M/STT & (CE)

POWER WAVE 455M/STT & (CE) Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-450 P-450 PARTS LIST FOR POWER WAVE 455M/STT & (CE) P-450-A P-450-A ILLUSTRATION

More information

Cutting and stripping tools

Cutting and stripping tools Cutting and stripping tools Introduction 2 Cutting and stripping tool 0.02-10 mm² (16 mm²) 3 Stripping tool for cables Ø 2.5-40 mm 4 Tools for cutting and stripping of conductors 0.5-6 mm² and for cutting

More information

Installation Instructions Hustler 6-BTV Trap Vertical

Installation Instructions Hustler 6-BTV Trap Vertical Installation Instructions Hustler 6-BTV Trap Vertical ASSEMBLY 1. Check the package contents against the parts list on page 2. 2. WARNING. Installation of this product near power lines is dangerous. For

More information

www.klmtechgroup.com TABLE OF CONTENT

www.klmtechgroup.com TABLE OF CONTENT Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature LED LEONARDO 120 W LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature OVERVIEW The LED LEONARDO 120W is a highly efficient Fresnel lens spotlight using

More information

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL 34471 (352) 629-8421; FAX: (352) 629-8264 BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV 1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled

More information

POLE MOUNT SYSTEM-3 INSTALLATION

POLE MOUNT SYSTEM-3 INSTALLATION 1 May 2014 POLE MOUNT SYSTEM-3 INSTALLATION The Pole Mount System-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker products to be mounted to pole structures. The only

More information

800 Communications Circuits

800 Communications Circuits ARTICLE 800 Communications Circuits INTRODUCTION TO ARTICLE 800 COMMUNICATIONS CIRCUITS This article has its roots in telephone technology. Consequently, it addresses telephone and related systems that

More information

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form 3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO

More information

Pole Guying More Complicated Than Meets the Eye. NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. jason.settle@gdsassociates.

Pole Guying More Complicated Than Meets the Eye. NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. jason.settle@gdsassociates. Pole Guying More Complicated Than Meets the Eye NRECA TechAdvantage 2014 Presented by Jason Settle, P.E. jason.settle@gdsassociates.com Pole Guying Strength of components NESC vs. RUS Guy Factor Grounding

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS TESTS ON TRANSFORMERS 1. IR Values a) For 33/11 KV Power Transformer 2500 V megger is to be need. b) Power Transformer neutral Earthing is

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Hyperlinks are Inactive

Hyperlinks are Inactive Prepared by: NIB/EOB PLANNING GUIDE FOR SINGLE CUSTOMER SUBSTATIONS SERVED FROM TRANSMISSION LINES 05503 Department: Electric T&D Section: T&D Engineering and Technical Support Approved by: G.O. Duru (GOD)

More information

RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LTD. (Regd. Office: Vidyut Bhavan, Janpath, Jyoti Nagar, Jaipur 302005) CONSTRUCTION MANUAL FOR SUB STATIONS

RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LTD. (Regd. Office: Vidyut Bhavan, Janpath, Jyoti Nagar, Jaipur 302005) CONSTRUCTION MANUAL FOR SUB STATIONS RAJASTHAN RAJYA VIDYUT PRASARAN NIGAM LTD. (Regd. Office: Vidyut Bhavan, Janpath, Jyoti Nagar, Jaipur 302005) CONSTRUCTION MANUAL FOR SUB STATIONS F O R E W O R D The Engineers experienced in the field

More information

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE

TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE A. GENERAL NOTES: Service entrance line and load conductors, conduit straps, weatherhead, lock nuts, bushings, connectors, and

More information

XLPE PRODUCTION PLANT FOR THIRUVALLA UNIT OF TRACO CABLE LTD

XLPE PRODUCTION PLANT FOR THIRUVALLA UNIT OF TRACO CABLE LTD PROJECT PROFILE ON XLPE PRODUCTION PLANT FOR THIRUVALLA UNIT OF TRACO CABLE LTD Prepared by: TRACO CABLE COMPANY LIMITED IV TH FLOOR, KSHB OFFICE COMPLEX PANAMPILLY NAGAR KOCHI-682036 September 2012 PROJECT

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION NCRMI/LIB/ELE001/15 4.09.2015 Competitive sealed quotations are invited

More information

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12 SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications

More information

8' W x 8' H or 10' H Peak Style Shelter Assembly Instructions

8' W x 8' H or 10' H Peak Style Shelter Assembly Instructions ' W x ' H or ' H Peak Style Shelter Assembly Instructions Description ' x ' x ' Peak Style Shelter - Gray ' x ' x ' Peak Style Shelter - Gray Recommended Tools Please read instructions COMPLETELY before

More information

ILLUSTRATED PARTS LIST

ILLUSTRATED PARTS LIST TW400 WITH 390cc HONDA ENGINE 390cc 2 WHEEL DRIVE UTILITY VEHICLE ILLUSTRATED S LIST 390cc 2WD B O D Y D I A G R A M 390cc 2WD F R A M E D I A G R A M 390cc 2WD D R I V E T R A I N D I A G R A M DESCRIPTION

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

ELECTRICAL WORKS FOR CPCB ZONAL OFFICE AND LABORATORY AT BANGALORE. Consultants: SRIMATHA ENTERPRISES

ELECTRICAL WORKS FOR CPCB ZONAL OFFICE AND LABORATORY AT BANGALORE. Consultants: SRIMATHA ENTERPRISES Item No. BILL OF QUANTITIES WITH SPECIFICATIONS - ELECTRICALS Qty. Unit Rate Description 1.0 415VOLTS MAIN DISTRIBUTION BOARDS CONSTRUCTION (i) Sheet steel - 2mm thick for frames and equipment mounting

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS AC AND DC GENERATOR SCHEMATIC ENGINE GENERATOR ASSEMBLY REF Description QTY PSS10 PSS12 1 Engine, Honda GX620K1VXC2 Code 637220 1 99779-000 GX670VXC2 Code 637220

More information

XL PREMIUM OIL COOLER KIT

XL PREMIUM OIL COOLER KIT -J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL.

BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL. BOQ FOR ELECTRICAL WORK OF HLST IN GROUND FLOOR AT S.B.I. LHO BHOPAL. Note: Use of Flexible conduits & Elbows in Circuit wiring is not allowed except in exceptional site conditions with the approval of

More information

SPARE-PARTS BOOK Z 150-195. Model: TABLE OF CONTENTS. Chapter 4.3: Alu.platform, flat 30mm laser L. Chapter 5: Cylinders

SPARE-PARTS BOOK Z 150-195. Model: TABLE OF CONTENTS. Chapter 4.3: Alu.platform, flat 30mm laser L. Chapter 5: Cylinders SPARE-PARTS BOOK TABLE OF CONTENTS Model: Z 50-95 Chapter 4.: Alu.platform, flat 0mm laser L PLZ044 Alu. platform Z, flat 0mm laser L Page 4 Chapter 5: Cylinders 5985 Lift cylinder Page 6 5986 Tilt cylinder

More information

SUBHEAD-I: POINT WIRING & SUBMAIN WIRING. Ru-Tech Services Inc. Page-1 Electrical BOQ.xls

SUBHEAD-I: POINT WIRING & SUBMAIN WIRING. Ru-Tech Services Inc. Page-1 Electrical BOQ.xls SUBHEAD-I: POINT WIRING & SUBMAIN WIRING 1.1 Wiring for light Point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed

More information

Mechanical arms, belts and sheets

Mechanical arms, belts and sheets Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black

More information

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE Toll Free Telephone Numbers Residential Services 800.454.3853 Commercial Services 800.653.5307 Utility Locating Company N.C. 800.632.4949 S.C. 888.721.7877

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables Engineering Department SEPTEMBER, 2007 GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables General Requirements This section applies to all public and private utilities,

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS GENERAL DESCRIPTION:

More information

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Universal Vehicle Power Supply 9007AX01. Installation Instructions Universal Vehicle Power Supply 9007AX01 Installation Instructions Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in

More information

Session 14 Cable Support Systems

Session 14 Cable Support Systems Session 14 Cable Support Systems Cable Support Systems in the IEC World A new IEC Standard, IEC61537 2001 has been developed If full details of the cabling layout are available then the likely cable load

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT

TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT TECHNICAL SPECIFICATIONS & SPECIAL CONDITIONS OF CONTRACT FOR ELECTRICAL WORKS CHAPTER 1 SPECIAL CONDITIONS OF CONTRACT 1.1 General 1.1.1 These Special Conditions of Contract supplement the General Instructions.

More information

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

SCHEDULE OF RATE FOR ARC FOR MAINTENANCE OF CP & ASSOCIATED SYSTEM FOR HVJ, DVPL - I and DVPL - II PIPELINE UNDER KHERA PIPELINE JURISDICTION

SCHEDULE OF RATE FOR ARC FOR MAINTENANCE OF CP & ASSOCIATED SYSTEM FOR HVJ, DVPL - I and DVPL - II PIPELINE UNDER KHERA PIPELINE JURISDICTION SCHEDULE OF RATE FOR ARC FOR MAINTENANCE OF CP & ASSOCIATED SYSTEM FOR HVJ, DVPL - I and DVPL - II PIPELINE UNDER KHERA PIPELINE JURISDICTION THE RATES QUOTED SHALL BE INCLUSIVE OF MATERIAL AND LABOUR

More information

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS PRIMARY METER POLE ELECTRIC SYSTEM BULLETIN No. 753 JUNE 1993, 2 ND PRINTING APRIL 2002 (Supersedes issue dated March 1983 and incorporates Nov.

More information

125 DUKE EU 2011 SPARE PARTS MANUAL: CHASSIS ENGLISH ART.NO.: 3CF8003K4EN

125 DUKE EU 2011 SPARE PARTS MANUAL: CHASSIS ENGLISH ART.NO.: 3CF8003K4EN SPARE PARTS MANUAL: CHASSIS ART.NO.: 3CF8003K4EN ENGLISH INDEX FRONT FORK, TRIPLE CLAMP HANDLEBAR, CONTROLS FRAME SIDE / CENTER STAND 3x 4x 5x 6x SHOCK ABSORBER SWING ARM EXHAUST SYSTEM AIR FILTER 7x

More information

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

Electrical Code Regulation

Electrical Code Regulation Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county

More information

FLOORTEC R 680 B. Part List US-English. Model: FLOORTEC R 680 B

FLOORTEC R 680 B. Part List US-English. Model: FLOORTEC R 680 B Model: Part List US-English Table of Contents General view 3 Rotomolded assembly 5 Chassis assembly 7 Drive assembly 9 Steering assembly 11 Control pedals assembly 13 Waste container assembly 15 Filter

More information

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document

More information

R O A D M A S T E R, I N C.

R O A D M A S T E R, I N C. R O A D M A S T E R, I N C. MOUNTING BRACKET KIT 14 8 7 4 13 5 6 ITEM QTY NAME MATERIAL 1...6...1/2" x 2 1/2" BOLT... 350099-00 2...2...1/2" x 1 1/2" BOLT... 350095-00 3...8...1/2" LOCK WASHER... 350309-00

More information

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property. INTRODUCTION These rules are issued for use by Customers, builders, electrical contractors, architects, engineers, etc. The rules require the installation of safe and adequate wiring and electrical equipment,

More information