1 Industrial controls Softstarters Type PSS & SSA - Low voltage Type SSM - Medium voltage Type PEB - Power electronic brake AC 1006 Type SSA Type SSM Type PSS Type PEB ABB Control Inc. Low Voltage Products and Systems

2 Softstarters Type PSA, SSA & SSM, Open & enclosed Type PEB Power Electronic Brakes Type PSS Softstarters General information & catalog number explanation Selection, open type Selection, enclosed Accessories Technical data Circuit diagrams Approximate dimensions & mounting information Type PSS Type SSA Softstarters General information & catalog number explanation Selection, open type Selection, enclosed Accessories Technical data Circuit diagrams Approximate dimensions Type SSA DLA Starters Type SSM Softstarters Description & general information Selection & catalog number explanation Technical data Approximate dimensions Type SSM Type PEB Power Electronic Brakes Description & general information Catalog number explanation Selection, open type Approximate dimensions, wiring diagram, open type Selection, enclosed type Approximate dimensions, wiring diagram, enclosed type Technical data Type PEB Terms & conditions Information Standard compliance and approvals ABB Control Inc. I

3 Notes II ABB Control Inc.

4 Softstarters Type PSS Type PSS General information ABB low voltage softstarters now cover the whole range from 3A to 1250A. The new PSS line brings a wide array of benefits for smaller motors in a flexible, compact form. Compact line PSS03 to PSS25 softstarters are a very compact solution for starting small motors with rated current from 3 to 25A. They are suitable for 230, 400, 500 and 600V and designed for DIN rail mounting. The built-in bypass contacts allow you to build space-saving, compact designs. Adjustable parameters include acceleration time and initial voltage for starting and deceleration time for stopping. In addition, these units cover a control voltage range of VAC/DC and 100V VAC. UL File # E Flexible line PSS18/30 to PSS142/245 softstarters provide a flexible solution for motor starting. Rated motor currents are covered from 18A to 142A when connected in line like a traditional full voltage starter. These units can also be wired inside the motor-delta, like a wye-delta starter, covering motors up to 245A. This flexibility makes it easier than ever before to replace wye-delta starters. The total solid state solution with no moving contacts in the power circuit is an attractive solution for applications with many starts per hour. Adjustable parameters include acceleration time, initial voltage and optional current limit for starting and deceleration time for stopping. UL File # E ABB Control Inc. 1.1

5 Catalog number explanation Type PSS PSS Open type PSS - 18/ F 3 Maximum motor current when connected in-line Maximum motor current when connected inside delta Control voltage F - 100V 120V, 50/60Hz L - 220V 240V, 50/60Hz Line voltage 500: 208V 500V 690: 575V 690V Type PSS PSS Enclosed type P18DF1-481AA Soft starter PSS enclosed Softstarter amps Options 1 A Start-stop pushbutton B Bypass contactor C 2 position selector switch D 3 position selector switch E Pilot light F Start-stop pushbutton and pilot light H 2 position selector switch and pilot light J 3 position selector switch and pilot light W Isolation contactor Connection type L: In-line D: Inside delta Fuse clip A 30A, 600V, Class J B 60A, 600V, Class J C 100A, 600V, Class J D 200A, 600V, Class J Combination type No digit non-combination F fusible disconnect B thermal magnetic circuit breaker M magnetic only breaker Enclosure 1 NEMA 1 2 NEMA NEMA 3R2 4 NEMA 42 X NEMA 4x stainless steel 2 Circuit Breaker Amp Ratings D 15 M 70 E 20 N 80 F 25 P 60 G 30 R 100?? H 35 S 125 J 40 T 150 K 50 U 175 L 60 V 200 MCP/MAG Only Rating A 3 E 50 B 5 F 100 C 10 G 150 D 25 Overload class 1 Class 10 overload 2 Class 20 overload Line voltage 20: 208V 120V control voltage 23: 230V 120V control voltage 38: 380V 220V control voltage 41: 415V 220V control voltage 48: 480V 120V control voltage 60: 600V 120V control voltage 1 For more options, see page By-pass contactor required. 3 See page 1.3 for the PSS03, PSS12 & PSS25 softstarters. 1.2 ABB Control Inc.

6 Open 3A 25A PSS Open type 1 Type PSS03-480B Operating voltage Maximum HP rating Maximum current Catalog List 50Hz 60Hz three phase amperes number price 1 3 PSS03-220B $ V 3 12 PSS12-220B PSS25-220B PSS03-400B V 5 12 PSS12-400B PSS25-400B PSS03-480B V PSS12-480B PSS25-480B V PSS12-600B PSS25-600B 445 Type PSS Type PSS25-480B 1 Overload protection not included; external overload relay must be in power circuit. ABB Control Inc. Discount schedule PSS 1.3

7 Open PSS18/30 PSS50/85 PSS85/147 Type PSS Connected inline 12 Maximum horsepower Maximum motor Catalog List current 208V 240V 480V 600V number price PSS18/30-500F $ PSS18/30-690F PSS30/52-500F PSS30/52-690F PSS37/64-500F PSS37/64-690F PSS44/76-500F PSS44/76-690F PSS50/85-500F PSS50/85-690F PSS60/ F PSS60/ F PSS72/ F PSS72/ F PSS85/ F PSS85/ F PSS105/ F PSS105/ F PSS142/ F PSS142/ F Connected inside delta 12 Maximum horsepower Maximum motor Catalog List current 208V 240V 480V 600V number price PSS18/30-500F $ PSS18/30-690F PSS30/52-500F PSS30/52-690F PSS37/64-500F PSS37/64-690F PSS44/76-500F PSS44/76-690F PSS50/85-500F PSS50/85-690F PSS60/ F PSS60/ F PSS72/ F PSS72/ F PSS85/ F PSS85/ F PSS105/ F PSS105/ F PSS142/ F PSS142/ F Catalog numbers are shown with 120V control. For 240V control, replace F with L in catalog number. 2 Overload protection not included; external overload relay must be in power circuit. 1.4 Discount schedule PSS ABB Control Inc.

8 Enclosed 1 NEMA 1, 12 Connected inline Maximum NEMA 1, 480V NEMA 1, 600V NEMA 12, 480V NEMA 12, 600V Maximum horsepower with Class 10 overload with Class 10 overload with Class 10 overload with Class 10 overload motor current 208V 240V 480V 600V Catalog number List price Catalog number List price Catalog number List price Catalog number List price P18L $ 1095 P18L2-481B $ P18L $1219 P18L2-601B $ P22L P22L2-481B P22L P22L2-601B P30L P30L2-481B P30L P30L2-601B P37L P37L2-481B P37L P37L2-601B P44L P44L2-481B P44L P44L2-601B P50L P50L2-481B P50L P50L2-601B P60L P60L2-481B P60L P60L2-601B P72L P72L2-481B P72L P72L2-601B P85L P85L2-481B P85L P85L2-601B P105L P105L2-481B P105L P105L2-601B P142L P142L2-481B P142L P142L2-601B 5025 Type PSS Connected inside delta Maximum NEMA 1, 480V NEMA 1, 600V NEMA 12, 480V NEMA 12, 600V Maximum horsepower with Class 10 overload with Class 10 overload with Class 10 overload with Class 10 overload motor current 208V 240V 480V 600V Catalog number List price Catalog number List price Catalog number List price Catalog number List price P18D $ 1095 P18D2-481B $ P18D $ 1219 P18D2-601B $ P22D P22D2-481B P22D P22D2-601B P30D P30D2-481B P30D P30D2-601B P37D P37D2-481B P37D P37D2-601B P44D P44D2-481B P44D P44D2-601B P50D P50D2-481B P50D P50D2-601B P60D P60D2-481B P60D P60D2-601B P72D P72D2-481B P72D P72D2-601B P85D P85D2-481B P85D P85D2-601B P105D P105D2-481B P105D P105D2-601B P142D P142D2-481B P142D P142D2-601B All enclosed softstarters include a control power transformer. 2 Provided with bypass in lieu of ventilation. ABB Control Inc. Discount schedule PSSE 1.5

9 Enclosed NEMA 1 Combination 1 Connected inline Type PSS Amps Maximum motor horsepower ratings FLA 208V 240V 480V 600V 480V with fusible disconnect 600V with fusible disconnect 480V with circuit breaker 600V with circuit breaker switch NEMA 1 switch NEMA 1 NEMA 1 NEMA 1 CatalogList CatalogList Catalog List CatalogList number price number price number price number price P18LF1-481A $ 1370 P18LB1-481E $ P18LF1-601A $ 1709 P18LB1-601E $ P22LF1-481B 1580 P22LB1-481G P22LF1-601B 1835 P22LB1-601G P30LF1-481B 1580 P30LB1-481J P30LF1-601B 1835 P30LB1-601J P37LF1-481B 1750 P37LB1-481K P37LF1-601B 2040 P37LB1-601K P44LF1-481C 2075 P44LB1-481L P44LF1-601B 2400 P44LB1-601L P50LF1-481C 2195 P50LB1-481N P50LF1-601C 2565 P50LB1-601N P60LF1-481C 2460 P60LB1-481N P60LF1-601C 2905 P60LB1-601N P72LF1-481C 2535 P72LB1-481R P72LF1-601C 3010 P72LB1-601R P85LF1-481D 3475 P85LB1-481S P85LF1-601D 4060 P85LB1-601S P105LF1-481D 3600 P105LB1-481T P105LF1-601D 4195 P105LB1-601T P142LF1-481D 4550 P142LB1-481V P142LF1-601D 5365 P142LB1-601V 5365 Connected inside delta Amps Maximum motor horsepower ratings FLA 208V 240V 480V 600V V with fusible disconnect 600V with fusible disconnect 480V with circuit breaker 600V with circuit breaker switch NEMA 1 switch NEMA 1 NEMA 1 NEMA 1 CatalogList CatalogList Catalog List CatalogList number price number price number price number price P18DF1-481A $ 1370 P18DB1-481E $ P18DF1-601A $ 1709 P18DB1-601E $ P22DF1-481B 1580 P22DB1-481J P22DF1-601B 1835 P22DB1-601J P30DF1-481B 1580 P30DB1-481J P30DF1-601B 1835 P30DB1-601J P37DF1-481B 1750 P37DB1-481K P37DF1-601B 2040 P37DB1-601K P44DF1-481C 2075 P44DB1-481L P44DF1-601B 2400 P44DB1-601L P50DF1-481C 2195 P50DB1-481N P50DF1-601C 2565 P50DB1-601N P60DF1-481C 2460 P60DB1-481N P60DF1-601C 2905 P60DB1-601N P72DF1-481C 2535 P72DB1-481R P72DF1-601C 3010 P72DB1-601R P85DF1-481D 3475 P85DB1-481S P85DF1-601D 4060 P85DB1-601S P105DF1-481D 3600 P105DB1-481T P105DF1-601D 4195 P105DB1-601T P142DF1-481D 4550 P142DB1-481V P142DF1-601D 5365 P142DB1-601V All softstarters on this page are provided with a bypass contactor in lieu of ventilation. 1.6 Discount schedule PSSE ABB Control Inc.

10 Enclosed Options Connected in-line Bypass or Electronic Electronic Start/Stop HOA Run NEMA 12 NEMA 3R NEMA 4 NEMA 4X Maximum Maximum horsepower isolation brake brake pushbuttons selector pilot adder adder adder adder motor contactor std. duty heavy duty switch light current 208V 240V 480V 600V List price List price List price List price List price List price List price List price $ 175 $ 1445 $ 1445 $ 72 $ 72 $ 135 $ 150 $ 150 $ 225 $ Type PSS Connected inside delta Bypass or Start/Stop HOA Run NEMA 12 NEMA 3R NEMA 4 NEMA 4X Maximum Maximum horsepower isolation pushbuttons selector pilot adder adder adder adder motor contactor switch light current 208V 240V 480V 600V List price List price List price List price List price List price List price List price $ 175 $ 72 $ 72 $ 135 $ 150 $ 150 $ 225 $ ABB Control Inc. Discount schedule PSSE 1.7

11 Accessories Type PSS Accessories Item Suffix List code price 1 adder Softstarters Start-stop pushbutton A $ 72 2 position selector switch C 72 3 position selector switch D 72 Pilot light run E 135 Start-stop pushbutton & pilot light F position selector switch & pilot light H position selector switch & pilot light J 207 Bypass contactor B see pg 1.7 Isolation contactor W see pg 1.7 Electronic brake (standard duty) Y see pg 1.7 Electronic brake (heavy duty) Z see pg 1.7 Service entrance, 3-wire SE3 100 Service entrance, 4-wire SE4 300 Lightning arrestor LA 320 Space heater, 100W with thermostat SH 600 Auxiliary relays Type N control relay (4 pole) CR 150 Electronic timer s On Delay TN s On Delay TN s Off Delay TF s Off Delay TF Phase failure phase reversal PFPR 375 Undervoltage relay UV 150 Overvoltage relay OV 180 Ground fault protection GFP 1500 Meters & metering Current transformer CT 250 Ammeter (including C.T.) AM 470 Ammeter & ammeter switch AMS 1800 Voltmeter VM 1200 Voltmeter & voltmeter switch VMS 1800 Elapsed time meter ETM 350 Operation counter OC 375 Wattmeter WM 2450 Additional auxiliary contact blocks for bypass or isolation contactors Contact Suffix List Price configuration code adder 1 N.O. & 1 N.C. 11 $ 54 2 N.O. & 2 N.C N.O. & 3 N.C Control transformers Size Standard VA 1 Price adder for extra VA 100VA 250VA 500VA 750VA All PSS sizes 50 $ 175 Current transformers for current limit function Technical For CatalogList data softstarter number price 60/1 2 turns PSS18/30 PSCT-60 40/1 1 turn PSS30/52 PSCT-40 50/1 1 turn PSS37/64 PSCT-50 60/1 1 turn PSS44/76 PSCT-60 75/1 1 turn PSS50/85 PSCT-75 75/1 1 turn PSS60/105 PSCT /1 1 turn PSS72/124 PSCT /1 1 turn PSS85/147 PSCT /1 1 turn PSS105/181 PSCT /1 1 turn PSS142/245 PSCT-200 $ VA requirements for softstarter only. 1.8 Discount schedule PSSE ABB Control Inc.

12 Technical data PSS03 PSS25 and PSS18/30 PSS142 /245 PSS03 PSS12 PSS25 PSS18/30 PSS142/245 Rated insulation voltage Uz V Rated operational Voltage Ue V SCR PIV ratings up to 500V up to 600V Starting capacity at max. rated current Ie 5 x Ie for 5 sec 5 x Ie for 5 sec 4 x Ie for 10 sec Number of starts per hour Overload class A Service factor % Ambient temperature During operation C -20 to to to During storage C -40 to to to +70 Degree of protection Main circuit IP20 IP20 IP20 (PSS18/ PSS44/76-500) IP10 (PSS50/ PSS72/124/-500) IP10 (PSS18/ PSS72/ ) IP00 (PSS85/147 PSS142/245) Type PSS Supply and control circuit IP20 IP20 IP20 Settings Ramp time during start s Ramp time during stop s Initial voltage during start % Current limit function xle No No Switch for Inside delta connection ON/OFF No No Yes Signal relay Bypass signal No4 No4 Yes Fault signal No No Yes Rated operational voltage Ue V 250 Rated thermal current Ith A 5 Rated operational current Ie at AC 15 (Ue=250V) A 1.5 Signal indication LED Ready to start/stand by ON Green Green Green Ramping up/down Yellow Yellow (flashing) No Completed start ramp T.O.R. Yellow Yellow Green General fault (internal) F1 Red Red External fault (phase loss) F2 Red Size related data Size Type A Max. power loss Max. SCR fuse Bussman Power requirements at max l e W rating (optional) fuses of supply circuit VA PSS03TA25DU A 170M PSS12 TA25DU A 170M PSS25 TA25DU A 170M PSS18/30 TA25DU A 170M PSS30/52 TA25DU A 170M PSS37/64 TA42DU A 170M PSS44/76 TA75DU A 170M PSS50/85 TA75DU A 170M PSS60/105 TA75DU A 170M PSS72/124 TA75DU A 170M PSS85/147 TA110DU A 170M PSS105/181 TA110DU A 170M PSS142/245 TA200DU A 170M When more than six starts per hour are required, contact your sales office. 2 Above 40 C, up to max 60 C, reduce the rated current with 0.8% per C. 3 Only if current transformer is connected (accessory). 4 The unit has built-in bypass contacts (AC-53b). 5 Total power loss: P Ltot = [3 x l e x 1.0] + 50 (W), reduced to 50W only when using by-pass. 6 50% on and 50% off, 3.5 times rated current and 7 second starting time. ABB Control Inc. 1.9

13 Technical data Cross section of connection cables PSS03 PSS25 and PSS18/30 PSS142/24 Type PSS PSS50/ PSS Type PSS PSS03 PSS12 PSS25 PSS18/ PSS72/ & PSS142/ & PSS18/ PSS85/ PSS72/ PSS142/ Main circuit Connection clamp Rigid solid/rigid stranded 1x AWG 12 AWG 6 AWG 4-8 AWG 1-8 See accessories Rigid solid/rigid stranded 2x AWG 12 AWG 8 AWG 4-8 AWG 4-8 See accessories Tightening torque (for guidance only) max. lb./in See accessories Connection bar Width and thickness mm 17.5 x 5 Hole diameter mm 8.5 Tightening torque (for guidance only) max. lb./in 79 Supply and control circuit Connection clamp Rigid solid/rigid stranded 1x AWG 12 AWG 12 AWG 12 AWG 12 AWG 12 Rigid solid/rigid stranded 2x AWG 12 Tightening torque (for guidance only) max. lb./in ABB Control Inc.

14 Circuit diagrams PSS03 PSS25 INCOMING LINES A B C WHEN SPECIFIED CIRCUIT PROTECTIVE DEVICE (WHEN SPECIFIED) CHFU H1 H2 H3 H4 CHFU CXFU CCT PSS SOFT STARTER L1 L2 L3 O L OFF HAND AUTO Type PSS T1 T2 T3 L1 L2 L3 T1 T2 T3 OL A1 NEUT A V AC/DC PSS03-25 A VAC MOTOR NOTES 1. ALL CONTROL WIRING TO BE 18GA. COLOR OF CONTROL WIRE SHALL BE PER VOLTAGE OF CONTACTOR COILS: RED - ALL AC VOLTAGES WHITE MAY BE USED ON THE GROUNDED SIDE OF THE AC CIRCUIT IF SPECIFIED. BLUE - ALL DC VOLTAGES 2. ALL DEVICES ARE SHOWN DE-ENERGIZED. 3. DO NOT USE SELECTOR SWITCHES WITH AUTO-RESET OVERLOAD RELAYS. CCT CHFU CXFU B OL 13 LEGEND CONTROL CIRCUIT TRANSFORMER CCT PRIMARY FUSE CCT SECONDARY FUSE BYPASS CONTACTOR OVERLOAD RELAY CONN POINT ON DEVICE WITH NUMBER REMOTE DEVICE CONN POINT AT TERMINAL BLOCK ABB Control Inc. 1.11

15 Circuit diagrams PSS18/30 PSS142/245 with In-line motor configuration INCOMING LINES A B C WHEN SPECIFIED CIRCUIT PROTECTIVE DEVICE (IF SPECIFIED) CHFU H1 H2 H3 H4 CHFU CXFU CCT SOFT STARTER L1 L2 L3 WHEN BYPASS IS SPECIFIED Type PSS T1 T2 T3 L1 L2 L3 T1 T2 T3 B O L STOP START WHEN BYPASS IS SPECIFIED B L1 L2 L3 OL A1 A2 T1 T2 T3 MOTOR N L GND STOP START COMMON FAULT BYPASS CURRENT LIMIT PSS 18/30-142/245 NOTES 1. ALL CONTROL WIRING TO BE 18GA. COLOR OF CONTROL WIRE SHALL BE PER VOLTAGE OF CONTACTOR COILS: RED - ALL AC VOLTAGES WHITE MAY BE USED ON THE GROUNDED SIDE OF THE AC CIRCUIT IF SPECIFIED. BLUE - ALL DC VOLTAGES 2. ALL DEVICES ARE SHOWN DE-ENERGIZED. 3. DO NOT USE SELECTOR SWITCHES WITH AUTO-RESET OVERLOAD RELAYS. ES M N L GND STOP O L START COMMON OFF HAND AUTO FAULT PSS 18/30-142/245 BYPASS CURRENT LIMIT CCT CHFU CXFU B OL 13 LEGEND CONTROL CIRCUIT TRANSFORMER CCT PRIMARY FUSE CCT SECONDARY FUSE BYPASS CONTACTOR OVERLOAD RELAY CONN POINT ON DEVICE WITH NUMBER REMOTE DEVICE CONN POINT AT TERMINAL BLOCK ES SET DIP SWITCH S1 AS SHOWN HOA CONNECTION DETAILS M 1.12 ABB Control Inc.

16 Circuit diagrams PSS18/30 PSS142/245 Delta motor configuration INCOMING LINES A B C WHEN SPECIFIED CIRCUIT PROTECTIVE DEVICE (IF SPECIFIED) CHFU H1 H2 H3 H4 CHFU CXFU CCT L1 L2 L3 PSS SOFT STARTER WHEN SPECIFIED O L STOP START T1 T2 T3 L1 L2 L3 T1 T2 T3 B WHEN BYPASS IS SPECIFIED B A1 A2 Type PSS ES M L1 L2 L3 T1 T2 T3 OL T3 T6 T2 T4 MOTOR T1 T5 N L GND STOP START COMMON FAULT PSS 18/30-142/245 BYPASS CURRENT LIMIT SET DIP SWITCH S1 AS SHOWN O L OFF HAND AUTO ES M NOTES 1. ALL CONTROL WIRING TO BE 18GA. COLOR OF CONTROL WIRE SHALL BE PER VOLTAGE OF CONTACTOR COILS: RED - ALL AC VOLTAGES WHITE MAY BE USED ON THE GROUNDED SIDE OF THE AC CIRCUIT IF SPECIFIED. BLUE - ALL DC VOLTAGES N L GND STOP START COMMON FAULT PSS 18/30-142/245 BYPASS HOA CONNECTION DETAILS CURRENT LIMIT 2. ALL DEVICES ARE SHOWN DE-ENERGIZED. 3. DO NOT USE SELECTOR SWITCHES WITH AUTO-RESET OVERLOAD RELAYS. CCT CHFU CXFU B OL 13 LEGEND CONTROL CIRCUIT TRANSFORMER CCT PRIMARY FUSE CCT SECONDARY FUSE BYPASS CONTACTOR OVERLOAD RELAY CONN POINT ON DEVICE WITH NUMBER REMOTE DEVICE CONN POINT AT TERMINAL BLOCK ABB Control Inc. 1.13

17 Circuit diagrams PSS18/30 PSS142/245 with Delta motor configuration with fault contactor INCOMING LINES A B C WHEN SPECIFIED CIRCUIT PROTECTIVE DEVICE (IF SPECIFIED) CHFU H1 H2 H3 H4 CHFU CXFU CCT Type PSS PSS SOFT STARTER L1 L2 L3 T1 T2 T3 L1 L2 L3 T1 T2 T3 WHEN SPECIFIED B L1 L2 L3 T1 T2 T3 WHEN SPECIFIED FC 1 O L STOP START WHEN FAULT CONTR IS SPECIFIED FC A1 A2 L1 L2 L3 T1 T2 T3 OL T3 T6 T2 T4 MOTOR WHEN BYPASS IS SPECIFIED B A1 A2 ES T1 T5 M SET DIP SWITCH S1 AS SHOWN N L GND STOP START COMMON FAULT BYPASS PSS 18/30-142/245 (WITH N.C. FAULT CONTACT) CURRENT LIMIT ES M O L HAND OFF AUTO NOTES 1. ALL CONTROL WIRING TO BE 18GA. COLOR OF CONTROL WIRE SHALL BE PER VOLTAGE OF CONTACTOR COILS: RED - ALL AC VOLTAGES WHITE MAY BE USED ON THE GROUNDED SIDE OF THE AC CIRCUIT IF SPECIFIED. BLUE - ALL DC VOLTAGES 2. ALL DEVICES ARE SHOWN DE-ENERGIZED. N L GND STOP START COMMON FAULT BYPASS PSS 18/30-142/245 (WITH N.C. FAULT CONTACT) HOA CONNECTION DETAILS CURRENT LIMIT 3. DO NOT USE SELECTOR SWITCHES WITH AUTO-RESET OVERLOAD RELAYS. CCT CHFU CXFU B OL 13 LEGEND CONTROL CIRCUIT TRANSFORMER CCT PRIMARY FUSE CCT SECONDARY FUSE BYPASS CONTACTOR OVERLOAD RELAY CONN POINT ON DEVICE WITH NUMBER REMOTE DEVICE CONN POINT AT TERMINAL BLOCK 1 Use appropriate contactor adder listed on page ABB Control Inc.

18 Inches Millimeters Approximate dimensions Open PSS03 PSS18-72 PSS03, PSS PSS Type PSS PSS18 to PSS44 (208V 480V) PSS18 to PSS72 (690V) Ø 6.5 ( 4x ) Ø 6.5 ( 4x ) ABB Control Inc. 1.15

19 Approximate dimensions Open PSS85 PSS Inches Millimeters PSS50 to PSS72 (208V 480V) PSS85 to PSS142 (208V 690V) Type PSS Ø 6.5 ( 4x ) Ø7 ( 4x ) ABB Control Inc.

20 Approximate dimensions Enclosed B C D 0.5" Dia A E Type PSS 208V - 500V Softstarter Softstarter Dimensions Dimensions type combination In-line (in.) Inside delta (in.) A B C D E A B C D E PSS18/ Softstarter only thru Softstarter with bypass PSS44/ Softstarter with fused disconnect Softstarter with circuit breaker PSS50/ Softstarter only thru Softstarter with bypass PSS72/ Softstarter with fused disconnect Softstarter with circuit breaker PSS82/ Softstarter only thru Softstarter with bypass PSS142/ Softstarter with fused disconnect Softstarter with circuit breaker V - 690V PSS18/ Softstarter only thru Softstarter with bypass PSS72/ Softstarter with fused disconnect Softstarter with circuit breaker PSS82/ Softstarter only thru Softstarter with bypass PSS142/ Softstarter with fused disconnect Softstarter with circuit breaker Dimensions remain the same if bypass contactor is added. ABB Control Inc. 1.17

21 Mounting information Minimum distance to wall / front D C A F E Type PSS B B Approximate dimensions (in./mm) Catalog Dimensions number D E F PSS18/ / / / /163 PSS50/ / / / /163 PSS18/ / / / /163 PSS85/ / / / /265 PSS85/ / / / /265 Minimum distance to wall / front (in./mm) A =.79/20 B =.39/10 C = 3.9/100 both top and bottom 1.18 ABB Control Inc.

22 Softstarters Type SSA Description Type SSA Softstarters Type SSA designed for starting pumps, conveyor belts, compressors, etc. Class 10 overcurrent protection standard for Type SSA. Class 20 available as an option Soft start Separately adjustable linear ramp with adjustable initial voltage Time: Adjustable from 0 60 sec. Initial voltage: Adjustable from 0 100% of full voltage Current limit is adjustable from 200% to 500% of the motors rated current. The current limit is active during the start ramp. 500% rated for 60 sec. Selectable soft stop Separately adjustable linear ramp with adjustable step-down voltage Time: Adjustable from 0 30 sec Step down: Adjustable from 0 100% of full voltage UL & cul approved UL File # E LED indicators Power on Run At speed Over temperature Overload Phase loss Shorted SCR Fault Over current Shunt trip Relay contacts Run relay Programmable relay either for fault condition signal or up to speed condition. Emergency shunt trip relay Optical output for fault indication Enclosed units include control power transformer as standard Type SSA ABB Control Inc. 2.1

23 General information Catalog number explanation Open & enclosed Open S S A Soft starter No digit without overload S with overload A Analog Overload class (100 HP & larger provided with overload) 1 Class 10 overload 2 Class 20 overload Horsepower Line voltage / 415 with 220V control voltage / 230 / 480 with 120V control voltage with 120V control voltage Type SSA Enclosed Soft starter settings S Analog Horsepower Combination type No digit non-combination F fusible disconnect B thermal magnetic circuit breaker M magnetic only breaker Enclosure 1 NEMA 1 2 NEMA NEMA 3R 2 4 NEMA 4 2 X NEMA 4x stainless steel 2 S 030 F A A Options 1 A Start-stop pushbutton B Bypass contactor C 2 position selector switch D 3 position selector switch E Pilot light F Start-stop pushbutton and pilot light H 2 position selector switch and pilot light J 3 position selector switch and pilot light W Isolation contactor Fuse clip A 30A, 600V, Class J B 60A, 600V, Class J C 100A, 600V, Class J D 200A, 600V, Class J E 400A, 600V, Class J F 600A, 600V, Class J G 800A, 600V, Class L H 1200A, 600V, Class L J 1600A, 600V, Class L K 2000A, 600V, Class L Circuit Breaker Amp Ratings D 15 M 70 W 225 E 700 E 20 N 80 X 250 F 800 F 25 P 60 Y 300 G 900 G 30 R 100 Z 350 H 1000?? H 35 S 125 A 400 J 1200 J 40 T 150 B 450 K 1600 K 50 U 175 C 500 L 2000 L 60 V 200 D 600 MCP/MAG Only Rating A 3 E 50 J 400 B 5 F 100 K 600 C 10 G 150 L 800 D 25 H 225 M 1200 Overload class 1 Class 10 overload 2 Class 20 overload 1 For more options, see page Must use by-pass contactor. Line voltage 20: 208V 120V control voltage 23: 230V 120V control voltage 38: 380V 220V control voltage 41: 415V 220V control voltage 48: 480V 120V control voltage 60: 600V 120V control voltage 2.2 ABB Control Inc.

24 Open Max. motor Maximum motor horsepower ratings 480V Without class 480V With class 600V Without class 600V With class amps 10 OLR 10 OLR 10 OLR 10 OLR Catalog List Catalog List Catalog List Catalog List FLA 208V 240V 480V 600V number price number price number price number price SA $ SA $ SA SA SA SA SA SA SA SA SA SSA $ SA SSA $ SA SSA SA SSA SA SSA SA SSA SA SSA SA SSA SA SSA SA SSA SA SSA SA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA SSA , SSA , SSA , SSA , SSA , SSA , SSA , SSA , SSA , SSA , SSA ,300 Type SSA 1 Use base mounted TA25 overload if Class 10 overload is needed. 2 Use base mounted TA25 overload if Class 10 overload is needed, mounted internally and connected to CT's 3 Class 20 overload relay optional, insert a 2 instead of 1 at the end of the part number for Class 20. ABB Control Inc. Discount schedule SSA 2.3

25 Enclosed 3 NEMA 1, 12 Type SSA Amps Maximum motor horsepower ratings FLA 208V 240V 480V 600V NEMA 1 480V NEMA 1 600V NEMA V NEMA V with class 10 overload with class 10 overload with class 10 overload with class 10 overload Catalog List Catalog List Catalog List Catalog List number price number price number price number price S $ 800 S B $ S $ 915 S B $ S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B S S B1 10, S S B1 11, S S B1 11, S S B1 12, S S B1 12, S S B1 13, S ,200 S B1 17, S ,140 S B1 18, S ,800 S B1 18, S ,740 S B1 19, S ,000 S B1 24, S ,200 S B1 25, S ,300 S B1 29, S ,030 S B1 31, S ,000 S B1 38, S ,000 S B1 40, S ,000 S B1 41, S ,300 S B1 43,600 1 Class 20 overload relay optional, insert a 2 instead of 1 at the end of the part number for Class Provided with bypass in lieu of ventilation. 3 All enclosed softstarters include a control power transformer. 2.4 Discount schedule SSAE ABB Control Inc.

26 Enclosed NEMA 1 Combination Amps Maximum motor horsepower ratings FLA 208V 240V 480V 600V V with fusible disconnect 600V with fusible disconnect 480V with circuit breaker 600V with circuit breaker switch NEMA 1 switch NEMA 1 NEMA 1 NEMA 1 Catalog List Catalog List Catalog List Catalog List number price number price number price number price S003F1-481A2 $ 1125 S003B1-481D2 $ S005F1-601A2 $ 1240 S005B1-601D2 $ S005F1-481A S005B1-481D S007F1-601A S007B1-601D S007F1-481A S007B1-481D S010F1-601A S010B1-601D S010F1-481A S010B1-481E S015F1-601A S015B1-601E S015F1-481B S015B1-481G S020F1-601B S020B1-601G S020F1-481B S020B1-481J S025F1-601B S025B1-601J S025F1-481B S025B1-481K S030F1-601B S030B1-601K S030F1-481C S030B1-481L S040F1-601C S040B1-601L S040F1-481C S040B1-481N S050F1-601C S050B1-601N S050F1-481C S050B1-481R S060F1-601C S060B1-601R S060F1-481D S060B1-481S S075F1-601D S075B1-601S S075F1-481D S075B1-481T S100F1-601D S100B1-601T S100F1-481D S100B1-481V S125F1-601D S125B1-601V S125F1-481E S125B1-481X S150F1-601E S150B1-601X S150F1-481E S150B1-481Y S200F1-601E S200B1-601Y S200F1-481E S200B1-481Z S250F1-601E S250B1-601Z S250F1-481F S250B1-481B S300F1-601F S300B1-601B S300F1-481F S300B1-481C S350F1-601F S350B1-601C S350F1-481F 1 10,590 S350B1-481D 1 10, S400F1-601F 1 11,180 S400B1-601D 1 11, S400F1-481G 1 11,640 S400B1-481E 1 11, S500F1-601G 1 12,325 S500B1-601E 1 12, S500F1-481H 1 15,400 S500B1-481G 1 15, S600F1-601H 1 16,340 S600B1-601G 1 16, S600F1-481H 1 17,000 S600B1-481J 1 17, S700F1-601H 1 17,940 S700B1-601J 1 17, S700F1-481J 1 20,500 S700B1-481J 1 20, S800F1-601J 1 21,900 S800B1-601J 1 21, S800F1-481J 1 25,800 S800B1-481K 1 25, S900F1-601J 1 27,530 S900B1-601K 1 27, S900F1-481K 1 30,200 S900B1-481K 1 30, S1000F1-601K 1 32,200 S1000B1-601K 1 32, S1000F1-481K 1 33,200 S1000B1-481L 1 33, S1125F1-601K 1 35,500 S1125B1-601L 1 35,500 Type SSA 1 Class 20 overload relay optional, insert a 2 instead of 1 at the end of the part number for Class Provided with bypass in lieu of ventilation. ABB Control Inc. Discount schedule SSAE 2.5

27 Enclosed Options Type SSA Amps Maximum motor horsepower ratings Bypass or Electronic Electronic Start / Stop HOA Run NEMA 12 NEMA 3R NEMA 4 NEMA 4X isolation brake brake pushbuttons selector pilot adder 1 adder1 adder 1 adder 1 contactor standard duty heavy duty switchlight FLA 208V 240V 480V 600V List price List price List price List price List price List price List price List price List price List price $ 100 $ 1130 $1130 $ 72 $ 72 $ 135 $ 100 $ 100 $ 150 $ , , , ,850 12, ,850 15, , , , ,000 15, , Must add bypass contactor. 2.6 Discount schedule SSAE ABB Control Inc.

28 Accessories Accessories Item Suffix List code price 1 adder Softstarters Start-stop pushbutton A $ 72 2 position selector switchc 72 3 position selector switchd 72 Pilot light run E 135 Start-stop pushbutton & pilot light F position selector switch & pilot light H position selector switch & pilot light J 207 Bypass contactor B see pg 2.6 Isolation contactor W see pg 2.6 Electronic brake (standard duty) Y see pg 2.6 Electronic brake (heavy duty) Z see pg 2.6 Service entrance, 3-wire SE3 100 Service entrance, 4-wire SE4 300 Lightning arrestor LA 320 Space heater, 100W with thermostat SH 600 Auxiliary relays Type N control relay (4 pole) CR 150 Electronic timer s On Delay TN s On Delay TN s Off Delay TF s Off Delay TF Phase failure phase reversal PFPR 375 Undervoltage relay UV 150 Overvoltage relay OV 180 Ground fault protection GFP 1500 Meters & metering Current transformer CT 250 Ammeter (including C.T.) AM 470 Ammeter & ammeter switchams 1800 Voltmeter VM 1200 Voltmeter & voltmeter switchvms 1800 Elapsed time meter ETM 350 Operation counter OC 375 Wattmeter WM 2450 Additional auxiliary contact blocks for bypass or isolation contactors Contact Suffix List Price configuration code adder 1 N.O. & 1 N.C. 11 $ 54 2 N.O. & 2 N.C N.O. & 3 N.C Type SSA Control transformers Size Standard VA Price adder for extra VA 100VA 250VA 500VA 750VA S003 S $ 175 S050 S $ 300 S200 S $ 500 $ 625 S500 S Add the suffix code after the last digit of the catalog number. 2 Specify on-delay or off-delay. ABB Control Inc. Discount schedule SSAE 2.7

29 Technical data for SA003 SSA300 SA003 SA007 SA020 SSA025 SSA030 SSA040 SSA050 Type SSA UL maximum HP ratings 208V V V V Softstarter UL maximum current SCR PIV ratings up to 500V up to 600V Temperature limits In enclosure 40 C 40 C 40 C 40 C 40 C Maximum operating temperature 50 C 50 C 50 C 50 C 50 C Minimum operating temperature 0 C 0 C 0 C 0 C 0 C Storage temperature -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C Harmonic contents During starts 5% 5% 5% 5% 5% During operation 2% 2% 2% 2% 2% Settings Initial voltage during start 0% to 100% 0% to 100% 0% to 100% 0% to 100% 0% to 100% Ramp time during start 0 to 60 sec. 0 to 60 sec. 0 to 60 sec. 0 to 60 sec.. 0 to 60 sec. Ramp time during stop 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. Current limit at start 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA Step down voltage 100% to 0% 100% to 0% 100% to 0% 100% to 0% 100% to 0% Output relay contacts Run relay Voltage Current Programmable relay Voltage Current Shunt trip relay Voltage Current Wire range Power connection AWG Control connection AWG Starting capacity 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. Total power loss Watts (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W Weight Lbs Control circuit power requirements VA 10 VA 10 VA 10 VA 25 VA 46 VA SSA060 SSA075 SSA100 SSA125 SSA150 SSA200 SSA250 SSA300 UL maximum HP ratings 208V V V V Softstarter UL maximum current SCR PIV ratings up to 500V up to 600V Temperature limits In enclosure 40 C 40 C 40 C 40 C 40 C Maximum operating temperature 50 C 50 C 50 C 50 C 50 C Minimum operating temperature 0 C 0 C 0 C 0 C 0 C Storage temperature -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C Harmonic contents During starts 5% 5% 5% 5% 5% During operation 2% 2% 2% 2% 2% Settings Initial voltage during start 0% to 100% 0% to 100% 0% to 100% 0% to 100% 0% to 100% Ramp time during start 0 to 60 sec. 0 to 60 sec. 0 to 60 sec. 0 to 60 sec.. 0 to 60 sec. Ramp time during stop 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. Current limit at start 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA Step down voltage 100% to 0% 100% to 0% 100% to 0% 100% to 0% 100% to 0% Output relay contacts Run relay Voltage Current Programmable relay Voltage Current Shunt trip relay Voltage Current Wire range Power connection AWG 14 1/ kcmil (2) kcmil (2) kcmil (2) kcmil Control connection AWG Starting capacity 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. Total power loss Watts (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W Weight Lbs Control circuit power requirements VA 46 VA 46 VA 46 VA 90 VA 90 VA 2.8 ABB Control Inc.

30 Technical data for SSA350 SSA1000 SSA350 SSA400 SSA500 SSA700 SSA800 SSA900 SSA1000 UL maximum HP ratings 208V V V V Softstarter UL maximum current SCR PIV ratings up to 500V up to 600V Temperature limits In enclosure 40 C 40 C 40 C 40 C 40 C Maximum operating temperature 50 C 50 C 50 C 50 C 50 C Minimum operating temperature 0 C 0 C 0 C 0 C 0 C Storage temperature -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C -40 C thru +70 C Harmonic contents During starts 5% 5% 5% 5% 5% During operation 2% 2% 2% 2% 2% Settings Initial voltage during start 0% to 100% 0% to 100% 0% to 100% 0% to 100% 0% to 100% Ramp time during start 0 to 60 sec. 0 to 60 sec. 0 to 60 sec. 0 to 60 sec.. 0 to 60 sec. Ramp time during stop 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. 0 to 30 sec. Current limit at start 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA 2 to 5 times FLA Step down voltage 100% to 0% 100% to 0% 100% to 0% 100% to 0% 100% to 0% Output relay contacts Run relay Voltage Current Programmable relay Voltage Current Shunt trip relay Voltage Current Wire range Power connection AWG (2) kcmil (2) kcmil (3) 4/0 600 kcmil (4) 4/0 600 kcmil (4) 300 kcmil 800 kcmil Control connection AWG Starting capacity 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. 500% for 60 sec. Total power loss Watts (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W (1.5 X FLA) + 30W Weight Lbs Control circuit power requirements VA 90 VA 90 VA 460 VA 460 VA 460 VA Type SSA ABB Control Inc. 2.9

31 Circuit diagram with bypass 20 HP and INCOMING LINES A B C CIRCUIT PROTECTIVE DEVICE (IF SPECIFIED) WHEN SPECIFIED CHFU H1 H2 H3 H4 CHFU CXFU CCT L1 L2 L3 SOFT STARTER L1 L2 L3 WHEN BYPASS IS SPECIFIED B SA003-SA020 SOFT STARTER RELAY TB T1 T2 T3 T1 T2 T3 Type SSA L1 L2 L3 T1 T2 T3 MOTOR OL O L BR 1 3 STOP START WHEN BYPASS IS SPECIFIED BR 7 2 A1 B A2 NOTES 1. COLOR OF CONTROL WIRE SHALL BE PER VOLTAGE OF CONTACTOR COILS: RED - ALL AC VOLTAGES WHITE MAY BE USED ON THE GROUNDED SIDE OF THE AC CIRCUIT IF SPECIFIED. BLUE - ALL DC VOLTAGES 2. ALL DEVICES ARE SHOWN DE-ENERGIZED. 3. DO NOT USE SELECTOR SWITCHES WITH AUTO-RESET OVERLOAD RELAYS TO CCT O L OFF HAND AUTO X TB X 7 TO CCT CONNECTION DIAGRAM FOR HOA MOVE JUMPER AT X6 TO X8. JUMPER LOCATED ON MAIN CONTROL BOARD. CCT CHFU CXFU B OL 13 LEGEND CONTROL CIRCUIT TRANSFORMER CCT PRIMARY FUSE CCT SECONDARY FUSE BYPASS CONTACTOR OVERLOAD RELAY CONN POINT ON DEVICE WITH NUMBER REMOTE DEVICE CONN POINT AT TERMINAL BLOCK 2.10 ABB Control Inc.

32 Circuit diagram with bypass INCOMING LINES A B C CIRCUIT PROTECTIVE DEVICE (IF SPECIFIED) WHEN SPECIFIED SSA SOFT STARTER L3 5 L1 L2 L3 T3 T3 CHFU H1 H2 H3 H4 CHFU L2 3 L1 1 T2 T2 T1 X1 X1 X1 T1 CXFU CCT T1 T2 T3 O L YEL BLK TB4 2 SSA SOFT STARTER TB5 EXTERNAL RESET 2 1 TB PROG. RELAY TB2 RUN RELAY SHUNT TRIP RELAY FAULT SIGNAL L1 L2 L3 T1 T2 T3 MOTOR OL PERMISSIVE INTERLOCK START STOP WHEN BYPASS IS SPECIFIED B Type SSA A1 A2 SSA SOFT STARTER W/BYPASS L1 L2 L3 REMOVE JUMPER X3 ON SOFTSTARTER PC BOARD WHEN BYPASS IS SPECIFIED X1 X1 X1 T1 T2 T3 L1 L2 L3 T1 T2 T3 L1 L2 L3 T1 T2 T3 B OL FOR BYPASS OPERATION SET DIP SWITCHES 1 & 2 AS SHOWN SWITCH LOCATED ON MAIN CONTROL BOARD ON OFF TO CCT PERMISSIVE INTERLOCK OFF HAND AUTO X TB CONNECTION DIAGRAM FOR HOA X TO CCT CCT CHFU CXFU B OL 13 MOTOR LEGEND CONTROL CIRCUIT TRANSFORMER CCT PRIMARY FUSE CCT SECONDARY FUSE BYPASS CONTACTOR OVERLOAD RELAY CONN POINT ON DEVICE WITH NUMBER REMOTE DEVICE CONN POINT AT TERMINAL BLOCK NOTES 1. COLOR OF CONTROL WIRE SHALL BE PER VOLTAGE OF CONTACTOR COILS: RED - ALL AC VOLTAGES WHITE MAY BE USED ON THE GROUNDED SIDE OF THE AC CIRCUIT IF SPECIFIED. BLUE - ALL DC VOLTAGES 2. ALL DEVICES ARE SHOWN DE-ENERGIZED. 3. DO NOT USE SELECTOR SWITCHES WITH AUTO-RESET OVERLOAD RELAYS ABB Control Inc. 2.11

33 Circuit diagram with bypass 100HP and INCOMING LINES A B C CIRCUIT PROTECTIVE DEVICE (IF SPECIFIED) WHEN SPECIFIED OL L1 L2 L3 L3 5 T3 T3 L2 3 T2 T2 L1 1 T1 T1 X1 X1 X1 CHFU H1 H2 CXFU CHFU H3 H4 CCT SOFT STARTER WHEN BYPASS IS SPECIFIED L1 L2 L3 B O L YEL BLK TB4 2 1 TB5 EXTERNAL RESET 2 1 SSA100-SSA1000 SOFT STARTER TB PROG. RELAY TB2 RUN RELAY SHUNT TRIP RELAY FAULT SIGNAL T1 T2 T3 T1 T2 T3 Type SSA MOTOR PERMISSIVE INTERLOCK START STOP WHEN BYPASS IS SPECIFIED B A1 FAN A2 REQUIRED FOR NEMA 1 UNITS WITHOUT BYPASS ON CCT CHFU CXFU B OL 13 OFF FOR BYPASS OPERATION SET DIP SWITCHES 1 & 2 AS SHOWN SWITCH LOCATED ON MAIN CONTROL BOARD LEGEND CONTROL CIRCUIT TRANSFORMER CCT PRIMARY FUSE CCT SECONDARY FUSE BYPASS CONTACTOR OVERLOAD RELAY CONN POINT ON DEVICE WITH NUMBER REMOTE DEVICE CONN POINT AT TERMINAL BLOCK NOTES TO CCT 1. COLOR OF CONTROL WIRE SHALL BE PER VOLTAGE OF CONTACTOR COILS: RED - ALL AC VOLTAGES WHITE MAY BE USED ON THE GROUNDED SIDE OF THE AC CIRCUIT IF SPECIFIED. BLUE - ALL DC VOLTAGES 2. ALL DEVICES ARE SHOWN DE-ENERGIZED. 3. DO NOT USE SELECTOR SWITCHES WITH AUTO-RESET OVERLOAD RELAYS PERMISSIVE INTERLOCK OFF HAND AUTO X TB CONNECTION DIAGRAM FOR HOA X TO CCT 2.12 ABB Control Inc.

34 S.TRIP AT SPEED POWER ON START VOLTAGE STEP DOWN SHORTED SCR RUN OVER CURRENT FAULT ACCEL ADJUSTMENTS RAMP TIME STOP VOLTAGE DECEL ADJUSTMENTS * DECEL MUST BE ENABLED * SHUNT TRIP CURRENT LIMIT PHASE LOSS TIME DECEL SHORTED OVER SCR CURRENT AT SPEED POWER ON RUN FAULT OVER TEMP LOAD OVER ACCEL ADJUSTMENTS START VOLTAGE RAMP TIME PHASE LOSS OVER TEMP OVER LOAD CURRENT LIMIT STEP STOP DECEL DOWN VOLTAGE TIME DECEL ADJUSTMENTS * DECEL MUST BE ENABLED * Approximate dimensions SA003 SSA Inches Millimeters SA DIA (2) SA DIA (2) DIA (2) Type SSA DIA (2) 7 SSA025 SSA DIA (4) ABB Control Inc. 2.13

35 G R O U D N Inches Millimeters Approximate dimensions SSA100 SSA400 SSA100 SSA WARNING LABEL DIA (4) SSA150 SSA Type SSA DIA (4) 11 SSA250 SSA DIA (4) ABB Control Inc.

36 L 1 SERIAL No. HEATSINK ELECTRICALLY HOT AVIS: RADIATEUR SOUS TENSION DISIPADOR DE CALOR ENERGIZADO T 1 L 2 HAZARDOUS VOLTAGE DANGER: HAUT VOLTAGE PELIGRO: ALTO VOLTAGE T 2 L 3 G R O U N D T 3 Approximate dimensions SSA500 SSA Inches Millimeters SSA500 SSA Type SSA SSA800 SSA DIA (6) L1 L2 L3 T1 DANGER T2 T3 WARNING DIA (4) 13 ABB Control Inc. 2.15

37 Approximate dimensions S003 S1000 S003 S400 S500 S1000 B C B C D 0.5" Dia A E A Dwg. A Dwg. B Type SSA Softstarter Softstarter Dwg Dimensions (inches) Type combination # A B C D E S003-S007 1 (NEMA 1) S003-S007 1 (NEMA 12, 3R, 4) S010-S020 1 (NEMA 1) S010-S020 1 (NEMA 12, 3R, 4) Softstarter Softstarter with fused disconnect A Softstarter with circuit breaker Softstarter Softstarter with fused disconnect A Softstarter with circuit breaker Softstarter Softstarter with fused disconnect A Softstarter with circuit breaker Softstarter Softstarter with fused disconnect A Softstarter with circuit breaker Softstarter S025-S075 Softstarter with fused disconnect A Softstarter with circuit breaker Softstarter Softstarter with bypass contactor S100-S125 Softstarter with fused disconnect A Softstarter with fused disconnect & bypass contactor Softstarter with circuit breaker Softstarter with circuit breaker & bypass contactor Softstarter Softstarter with bypass contactor S150-S200 Softstarter with fused disconnect A Softstarter with fused disconnect & bypass contactor Softstarter with circuit breaker Softstarter with circuit breaker & bypass contactor Softstarter A Softstarter with bypass contactor A S250-S400 Softstarter with fused disconnect A Softstarter with fused disconnect & bypass contactor B Softstarter with circuit breaker A Softstarter with circuit breaker & bypass contactor A Softstarter A Softstarter with bypass contactor B S500-S700 Softstarter with fused disconnect B Softstarter with fused disconnect & bypass contactor B Softstarter with circuit breaker B Softstarter with circuit breaker & bypass contactor B Softstarter A Softstarter with bypass contactor A S800-S1000 Softstarter with fused disconnect B Softstarter with fused disconnect & bypass contactor B Softstarter with circuit breaker B Softstarter with circuit breaker & bypass contactor B Dimension remains the same when a bypass contactor is added ABB Control Inc.

38 Softstarters Type SSM Medium voltage V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum contactor sized for across-the-line motor starting (optional on "soft start only" models) Bi-metallic thermal overload provides backup motor protection when operating in emergency bypass mode (optional on "soft start only" models) 120V fused control power transformer standard in line start section (optional on "soft start only" models) Digital controller provides solid state overload and numerous protective features for both the motor and the soft starter Fiber optic firing circuit for superior electrical noise isolation Programmable keypad with LCD and status LEDs for easy setup and operation Bypass vacuum contactor sized for across-the-line (emergency) motor starting is standard on all models to guarantee cool operation in all environments and extend unit life Heavy duty SCR stack assemblies with ring transformer isolated circuit for reliable, hard-firing gate pulse Isolated low voltage compartment provides maximum protection for operating personnel Mechanically interlocked medium voltage compartment Type SSM 1 Consult factory for higher voltages. ABB Control Inc. 3.1

39 The SSM advantage General information Type SSM Heavy duty SCR power assemblies Rated for 500 percent overload for 60 seconds, 125 percent continuous Field-proven design in use since 1975 Fiber optics gate-firing circuit using ring transformer isolation design for superior noise immunity Industrial real world packaging Load break/fault make disconnect switch with door safety interlocking mechanism Isolated, noise-immune low voltage control compartment NEMA 12 enclosure with bypass vacuum contactor included as standard Extra wiring space for MV cables for easy installation Custom engineered systems Available in special enclosures and lineups Numerous control component options including: Reversing contactors Motor protection relays Customer specified devices Horizontal and custom bus interconnects Various motor configurations including synchronous, wound rotor and two speed Type SSM Key construction features Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum contactor sized for across-the-line motor starting (optional on "soft start only" models) Bi-metallic thermal overload provides backup motor protection when operating in emergency bypass mode (optional on "soft start only" models) 120V fused control power transformer standard in line start section (optional on "soft start only" models) Digital controller provides solid state overload and numerous protective features for both the motor and the soft starter Programmable keypad with LCD and status LEDs for easy setup and operation Bypass vacuum contactor standard on all models to guarantee cool operation in all environments and extend unit life Heavy duty SCR stack assemblies with ring transformer isolated circuit for reliable, hard-firing gate pulse Isolated low voltage compartment provides maximum protection for operating personnel Mechanically interlocked medium voltage compartment Digital microprocessor control Full featured for flexibility, including dual ramp and S-curve software LCD status/alarm display and built-in programing keypad Serial communications port standard: RS485 with Modbus RTU protocol or RS232 with Windows interface In-depth motor and system protection monitors Monitors 18 separate parameters and maintains a nonvolatile fault memory 3.2 ABB Control Inc.

40 Selection Type SSM Volts Ratings 1 Soft start with line start section Optional soft start only 2 Max. Nominal Catalog List Catalog List amps max. HP number price number price SSM E-S SSM E SSM E-S 3 SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S 3 SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S 3 SSM E SSM E-S SSM E 6600/ SSM E-S SSM E SSM E-S 3 SSM E SSM E-S SSM E Custom line-up SSM E-S Catalog number explanation Type SSM SSM E - S Softstarter SSM medium voltage Voltage 23 = 2300V 33 = 3300V 41 = 4160V 66 = 6600/6900V S = Switchgear line start panel E = NEMA 12 enclosure 4 Amperage 160 = 160A 200 = 200A 320 = 320A 400 = 400A 600 = 600A 1 Contact factory for higher horsepower and voltage requirements. 2 Must be used with customer supplied line start panel. 3 Consult factory. 4 Consult factory for other enclosure types. ABB Control Inc. Discount schedule SSM 3.3

41 Technical data Type SSM Type of load Three phase medium voltage AC induction motors AC supply voltage 2300, 3300, 4160, 6600/6900 VAC +10% to -10% 50/60 Hz line voltages HP ratings 1 Up to V (600 Amps max) Overload ratings 125% Continuous 500% 60 Seconds Power circuit Series strings of SCR power modules (2,4 or 6 matched pairs of SCRs per phase depending on voltage rating) SCR peak inverse voltage Line voltage PIV rating / , / ,500 Transient voltage protection dv/dt circuits (1 per SCR power module) Vacuum bypass contactor Standard on all models, line start rated Ambient operating temperature 0 to 50 C (32 F to 122 F) (Optional -20 to 50 C with heaters) Control Digital microprocessor controller with read-out in English text Programmable in four languages (English, French, Spanish and German) Non-volatile memory for programming and faults Opto-isolated inputs Communications RS485 with modbus RTU protocol RS232 with Windows interface Auxiliary contacts FORM C8 250V Adjustments Motor FLA Dual adjustments Two independent settings for: Initial voltage 10 95% of nominal voltage Current limit % of motor FLA Acceleration time 2 90 seconds Deceleration time 2 90 seconds Decel - final torque 0 10% sensitivity Pump control Four closed loop start and stop curves Pulse start % line voltage Under voltage trip 70 90% (adjustable trip delay) Over voltage trip % (adjustable trip delay) Under current trip 20 90% of motor FLA (adjustable trip delay) Allowable re-starts 0 10 (adjustable time inhibit) Motor and starter protection Electronic overload Inverse time, % of motor FLA Electronic shear pin Trips within 1 cycle of setpoint Phase loss One or more phases missing Phase sequence Phase sequency incorrect Over voltage Trips at high line setpoint Under voltage Trips at low line setpoint Stall protection Starting process is not complete Shorted SCR Internal fault detected Error connection Internal fault/motor connection Starter over-temp Heatsink over temperature Line start section Load break/fault make disconnect switch with automatic grounding arm and viewing window Fuses with blown fuse indicator In-line vacuum contactor Control power transformer with fused primary/secondary Packaged in common enclosure with soft start Optional "Soft Start" (requires customer supplied line start panel) Statistical data Total amount of run time since soft start was reset Amount of time it took motor to start during last period Maximum current during last start period Total number of starts since soft start was reset The cause of the last fault Percentage of current at last trip Total number of trips since soft start was reset Elevation 1000 m / 3300 ft. without derating (contact factory for higher elevations) Enclosure NEMA 12, top and bottom entrance plates 11 gauge steel ASA #61 gray paint with lifting eyes 1 Consult factory for higher horsepower and voltage requirements. 3.4 ABB Control Inc.

42 Approximate dimensions B C A Soft start with line start section (inches) Optional softstart only (inches) Model number A B C Model number A B C SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E SSM E-S SSM E Type SSM ABB Control Inc. 3.5

43 Notes Type SSM 3.6 ABB Control Inc.

44 Softstarters Power electronic brakes Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB) Series features full-wave DC braking which can be adjusted to stop your load quickly, repeatedly and reliably...even if load conditions change. Unlike other brakes that only provide voltage control, the PEB Series is a current regulated brake. It automatically adjusts for resistance changes in the motor windings due to any input voltage fluctuations. What does this mean? Repeatable, reliable operation every time you stop your motor. An exceptionally accurate method of microprocessor controlled sensing determines when the motor shaft has come to a stop. Braking current is removed when the motor stops, eliminating excess braking current which means longer motor life. Built-in jogging circuitry allows you to select the time you need for machine setup and positioning without applying DC current to the motor windings. DC current is only applied when system setup is complete... no excess current, no excess heating, no premature motor failure. The PEB Series has a built-in feature to control a mechanical holding brake. Any fault indication automatically enables the mechanical brake for failsafe operation. The PEB Series has been designed and tested to meet the most stringent industry standards: UL & cul. type PEB ABB Control Inc. 4.1

45 Catalog number explanation Type PEB PEB Maximum brake amps Enclosure No digit Open chassis 1 NEMA 1 2 NEMA 12 3 NEMA 3R 4 NEMA 4 X NEMA 4X Voltage Type PEB 4.2 ABB Control Inc.

46 Power electronic brakes Open PEB PEB Max 208V 240V 480V 600V amps Horsepower Catalog Horsepower Catalog Horsepower Catalog Horsepower Catalog List 1 Std. duty Hvy. duty number Std. duty Hvy. duty number Std. duty Hvy. duty number Std. duty Hvy. duty number price PEB PEB PEB PEB $ PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB , PEB PEB PEB PEB ,000 NOTE: If duty cycle is not known, it is recommended to use the extra duty brake since braking current can be adjusted down to meet actual load requirements. type PEB 1 Never exceed the motor FLA without checking the motor manufacturers data with regards to application duty cycle. ABB Control Inc. Discount Schedule SSP 4.3

47 Power electronic brakes Open Approximate dimensions & Wiring diagram Approximate dimensions (inches) B C E F A D Model No. A B C D E F PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB Type PEB Wiring diagram LINE POWER L1 L2 START/STOP CONTROL L1 STARTER INTERLOCK L1 L2 L3 BRAKE COMMAND PEB POWER ELECTRONIC BRAKE OPTIONAL DISABLE MECHANICAL BRAKE MECH BRAKE RELAY A1 M A2 95 OL 96 T1 T2 T3 L1 L2 L3 T1 T2 T3 M OL T1 T2 T3 MECHANICAL BRAKE COIL MOTOR N 4.4 ABB Control Inc.

48 Power electronic brakes Enclosed, NEMA 1 Options 1 Model number NEMA 12 NEMA 3R NEMA 4 NEMA 4X PEB-010 $ 100 $ 100 $ 150 $ 450 PEB PEB PEB PEB PEB PEB PEB PEB PEB Maximum motor HP ratings Maximum 208V 240V 480V 600V Amps Standard Heavy Standard Heavy Standard Heavy Standard Heavy FLA Duty Duty Duty Duty Duty Duty Duty Duty NEMA 1, 480V NEMA 1, 600V List Catalog number Catalog number price PEB PEB $ PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB , PEB PEB ,500 NOTE: See below for additional enclosure styles and price adders. type PEB 1 Add to list price of NEMA 1 enclosed products and change part number appropriately. ABB Control Inc. Discount Schedule SSPE 4.5

49 Power electronic brakes Enclosed Approximate dimensions & Wiring diagram Approximate dimensions (inches) 1 B C E F A D Wiring diagram Model No. A B C D E F PEB PEB PEB PEB PEB PEB PEB PEB PEB PEB Type PEB L1 L2 START/STOP CONTROL L1 LINE POWER STARTER INTERLOCK L1 L2 L3 BRAKE COMMAND PEB POWER ELECTRONIC BRAKE OPTIONAL DISABLE MECHANICAL BRAKE MECH BRAKE RELAY A1 M A2 95 OL 96 T1 T2 T3 L1 L2 L3 T1 T2 T3 M OL T1 T2 T3 MECHANICAL BRAKE COIL MOTOR N 1 Dimensions apply to NEMA 1, NEMA 12, NEMA 3R and NEMA 4 enclosures. Consult factory for NEMA 4X dimensions. 4.6 ABB Control Inc.

50 Technical data Item Specification Voltage rating Models rated from V ±10% Selectable for 50/60Hz ± 2 Hz Current ratings Output capacity Power circuit Transient protection Fusing Control circuit Control method Operator adjustments Adjustment ranges Inputs Outputs Auxilliary contact ratings LED Status indicators Operating design temperature Ambient conditions Approvals A in 10 sizes: 10, 24, 50, 100, 200, 300, 400, 550, 800, 1000A 25% duty cycle at 100% unit rating Full wave bridge, 4 SCRs, designed for use without isolation contactors RC snubber dv/dt circuit on each SCR device Approved for use with existing motor starter fusing when unit is sized for motor FLA. Consult NEC for any other fusing requirements. Self-powered directly from line terminals. No separate control voltage required Microprocessor unit controls sequencing, I/O monitoring and status annunciation. Braking current is adjustable via true RMS regulated control using phase angle firing of SCRs. Brake Time and Jog Time = 7 position binary dipswitch Brake Current = potentiometer Brake Jog Times = seconds in 1 sec. increments Brake Current = Up to 100% unit rating Starter Monitor = Dry input for auxiliary contact from motor starter. Jumper selectable for N.O. or N.C. contact. Brake Disable = Dry input for N.O. contact to disable braking before or during operation. Can be wired to the starter thermal overload N.O. auxiliary contact to prevent braking of overloaded motor. Motor Power Sensor (T3) = voltage input used for sensing motor power presence in sequencing/status circuit and for zero speed sensing during braking Starter Coil Interlock = Two sets of FORM C relay contacts for use in interlocking the starter coil and/or other devices to prevent energizing as the braking power is applied. Mechanical Brake Release = N.O. relay contact for use in controlling electro-mechanical brake as a holding brake. When the PEB Series is disabled, this circuit controls the mechanical brake normally as if it is the only brake in the system. 5 amps, 250VAC max Large LEDs: Braking = green; Fault = red Small LEDs: Power On, Jog/Armed, Brake Off, Disabled, Over Temp, and Wiring Error 0-50 C ( F) open 0-40 C ( F ) enclosed 0-95% relative humidity ft (1000M) elevation UL, cul Listed type PEB ABB Control Inc. 4.7

51 Notes Type PEB 4.8 ABB Control Inc.

52 Terms & conditions These terms and conditions govern all sales and shipments of control equipment products (including parts and accessories). ABB Control Inc. hereby gives notice of its objection to any different or additional terms and conditions except for such as may be expressly accepted by it in writing. Prices Prices are subject to change without notice. Prices will be the prices in effect at the time of shipment by ABB Control Inc. and include freight, prepaid and allowed to first destination in the continental United States. In the event of a price change, the effective date of the change will be the date shown on the new price discount sheets. However, where a price change is made by letter or telegram, the effective date will be given as part of the announcement. Taxes The price does not include any Federal, state or local property, license, privilege, sales, use, excise, gross receipts or other like taxes which may now or hereafter be applicable. Payment by ABB Control Inc. of any such taxes shall be for the account of purchaser. Standard Terms of Payment Standard terms of payment are according to the appropriate discount schedule (AC AC 5002). Payment and Late Charges ABB Control Inc. may require full or partial payment in advance if, in its sole judgement, the financial condition of the purchaser, at any time prior to delivery, does not merit the terms of payment specified. If shipments are delayed by the purchaser or by reason of any of the causes referred to in the paragraph entitled "Excusable Delay", payments shall become due from the date when ABB Control Inc. is prepared to make shipment. Products held for the purchaser as a result of such delay shall be at the risk and expense of the purchaser. If the purchaser fails to pay any invoice when due, ABB Control Inc. may defer deliveries under this or any other contract with purchaser, except upon prior receipt of satisfactory security for or cash in payment of any such invoice. Failure on the part of purchaser to pay invoices when due shall at the option of ABB Control Inc. constitute a default under this contract. A service charge, the lesser of the highest rate allowed by law or 11/2% per month, or fraction thereof, for a maximum charge of 18% per annum will be charged on all overdue accounts. Delivery Delivery of products shall be FOB point of shipment regardless of transportation costs being "allowed", "prepaid" or collect". Where the scheduled delivery of products and parts is delayed by the purchaser or by reason of any of the causes referred to in the paragraph entitled Excusable Delay, ABB Control Inc. may deliver such products by moving them to storage for the account of and at the risk of the purchaser. Shipping dates are approximate and are based upon prompt receipt of all necessary information from purchaser. ABB Control Inc. reserves the right to make delivery in installments. Purchaser Pick-up No allowance will be made in lieu of transportation charges if the purchaser accepts shipment at the factory, warehouse or freight station. Transportation charges will not be deducted from the purchase price. Origin, Method of Shipment and Routing ABB Control Inc. shall determine the point of origin of shipment, the method of transportation and the routing of shipment. Costs for shipment by means requested by purchaser different from ABB Control Inc.'s standard means of shipment are invoiced to the purchaser as a separate charge. Freight charges will be added to the price of any order under $100. Excusable Delay ABB Control Inc. shall not be liable for loss, damage, detention or delay, nor be deemed to be in default from causes beyond its reasonable control, including without limitation, fire, flood, strike or other labor difficulty, act or omission of any governmental authority or of the purchaser, insurrection or riot, embargo, delays or shortage in transportation or inability to obtain necessary labor, materials or manufacturing facilities from usual sources. In the event of delay in performance due to any such cause, the date of delivery will be postponed by such length of time as may be reasonably necessary to compensate for the delay. Warranty ABB Control Inc. warrants that on date of shipment to purchaser, the goods will be the kind and quality described herein, merchantable and free of defects in workmanship and material. If within one year from date of initial operation, but not more than eighteen months from date of shipment, should any failure to conform with this warranty appear within such time, ABB Control Inc. shall, if given prompt notice by purchaser, correct such nonconformity, at its option, either by repair or replacement F.O.B. repair facility or by refund of the purchase price of the nonconforming product or part. Return of products to ABB Control Inc. pursuant to this paragraph shall be at purchaser's risk and expense. The foregoing warranty is exclusive and in lieu of all other warranties of quality, expressed or implied, and all other warranties, including any warranty of merchantability or fitness for a particular purpose are hereby disclaimed. Correction of nonconformities in the manner and for the period of time provided above shall be purchaser's exclusive remedy and shall constitute fulfillment of all liabilities of ABB Control Inc. whether in warranty, strict liability, contract, negligence, tort or otherwise with respect to any nonconformance or defect in the product. The foregoing warranty shall not apply to any product which has been: a) improperly repaired or altered, b) subjected to misuse, misapplication, negligence or accident, c) used in a manner contrary to manufacturer's directions. Limitation of Liability ABB Control Inc.'s liability to purchaser on any claim in connection with the product shall not exceed the purchase price of the product which gives rise to the claim. IN NO EVENT SHALL ABB CONTROL INC. BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES whether in warranty, contract, strict liability, tort, negligence or otherwise including but not limited to loss of profits or revenue, loss of use of the product or any associated product, cost of capital, cost of substitute products, facilities or services, downtime costs or claims of customers of the purchaser for such or other damages. Except as prohibited by law, all causes of action against ABB Control Inc. shall expire unless brought within one year of the time of accrual thereof. ABB CONTROL INC. NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME FOR IT ANY OTHER OR FURTHER LIABILITY THAN AS SET OUT ABOVE. Patent Indemnity ABB Control Inc. will at its own expense defend any suit which may be brought against the Purchaser based on a claim that any apparatus or part furnished under contract constitutes an infringement of any United States letter patent (provided ABB Control Inc. is notified promptly of such suit and copies of all papers therein are delivered to ABB Control Inc.), and ABB Control Inc. agrees to pay all judgements and costs recovered in any such suit and to reimburse the Purchaser for costs of expenses incurred in the defense of any such claim or suit. In case said apparatus or any part is held to constitute infringement and the use of the apparatus or part is enjoined, ABB Control Inc. shall at its own expense, either procure for the Purchaser the right to continue using the apparatus or part or replace it with non-infringing apparatus; or modify it so it becomes non-infringing, or remove the apparatus and refund the purchase price and the transportation and installation cost thereof. The foregoing states the entire liability of ABB Control Inc. for patent infringement by apparatus or any part thereof. Shipping loss or damage In the event of shipping loss or damage: 1) Notification must be given to ABB Control Inc. within 72 hours of delivery; 2) Written notice of apparent loss or damage must be made on the carrier's delivery receipt; and 3) Concealed damage must be immediately reported to the delivering carrier with a request for inspection. Purchaser shall comply with the foregoing procedure whether or not ABB Control Inc. has the risk of loss at the point of loss or damage to the shipment. Title risk of loss The products sold hereunder shall remain the property of ABB Control Inc. and shall remain personal property until fully paid for in cash, and purchaser agrees, if requested by ABB Control Inc. to execute a further security agreement covering the products sold, and to perform all acts which may be necessary to perfect and assure retention of title to such products by ABB Control Inc. Not withstanding any agreement with respect to delivery terms, risk of loss or damage shall pass to the purchaser and delivery shall be deemed to be complete upon delivery to a private or common carrier or upon moving into storage, whichever occurs first, at the point of shipment. Termination Any order or contract may be terminated by the purchaser only on written notice and upon payment of reasonable and proper termination charges, including without limitation, all costs identified to the order of contract incurred by ABB Control Inc. up to the date of notice of termination and all charges incurred by ABB Control Inc. in respect of the termination. ABB Control Inc. 5.1

53 Terms & conditions Returns In no event will ABB Control Inc. be responsible for unauthorized return of products. Returns will be accepted only at ABB Control Inc.'s option and subject to terms specified by ABB Control Inc. Authorization and shipping instructions for return of products must be obtained from ABB Control Inc. prior to return shipment. Product must be returned with proper identification. When a purchaser requests authorization to return for his own reasons, the return is subject to a minimum restocking charge of 20% for standard inventoried product and for any transportation paid by ABB Control Inc., both out and ingoing. Returns will be accepted up to 60 days after invoice date. Goods returned for purchaser's reason are subject to inspection and must be in good working condition, as new, and in original cartons. Purchase orders Except as provided below, all orders must be in writing and show quantities and prices, complete description (including catalog numbers) of products requested and mutually agreed delivery dates. Verbal orders received via telephone or otherwise must be confirmed within 5 days either by mail, telex or the equivalent. Verbal orders with a purchase price over $5,000 will not be processed until such written confirmation is received. Unless otherwise agreed in writing, an addition to a previously entered order will be accepted only at then applicable prices, discount schedules, conditions of sale, etc. Special quotations Special quotations will automatically expire 30 days from issuance unless renewed in writing by ABB Control Inc. Assignment Any assignment of this contract, or any rights hereunder, without prior written consent of ABB Control Inc. by a duly authorized representative thereof shall be void. Partial invalidity If any provisions herein or portions thereof conflict with any statute or rule of law of the jurisdiction of applicable law or wherein the contract may be sought to be enforced, then such provisions or portions thereof shall be deemed void to the extent that they may so conflict, but without invalidating the remaining portions of such provisions or other provisions hereof. Remedies The remedies expressly provided for in the Conditions of Sale shall be in addition to any other remedies which ABB Control Inc. may have under the Uniform Commercial Code or other applicable law. Choice of law The construction and performance of this contract and the rights and remedies of the parties hereto shall be governed by the laws of the State of Texas. 5.2 ABB Control Inc.

54 Notes ABB Control Inc. 5.3

55 Notes 5.4 ABB Control Inc.

56 Notes ABB Control Inc. 5.5

57 Standard compliance and approvals The CE Mark Worldwide approvals 1 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 CEI EN BS4752 NCF 120 IEC 947 UL489 CSA C22.2 VDE 0660 The CE Mark Within the European Union, EU, conformity of products and the proper application of the CE marking to machines and control equipment is necessary for marketing electrical equipment. The intent is to ensure compliance with all relevant EU Directives. ABB Low Voltage Apparatus ABB is a global group serving customers in electric power generation, transmission and distribution, industrial building systems, and rail transportation. ABB Low Voltage Apparatus develops, produces and markets low voltage products such as disconnect switches, contactors, starters, pushbuttons, soft starters, arc guard systems, relays, minicontactors, manual motor starters, Isomax MCCBs, and MCBs. With six manufacturing units within the European Union, we are ideally located to develop, manufacture and provide low voltage equipment to comply with the EU directive. Background The guarantee of free trade of goods within the Community is the most important objective. This will eliminate trade restrictions that result from different technical regulations in each individual member country. Harmonization of existing European standards and regulations, is being accomplished and already partially realized. Based on this goal, a new concept for creating directives was formed in 1985 by the European Community (EC) Commission to produce directives with a wide range of application which contain only the most basic safety requirements. The CE Mark The CE mark is prescribed by law and assures the European free trade of goods. It is short for Communauté Européen, and is displayed on goods and/or packaging which acts as an external symbol for the inspection of products. It also illustrates the manufacturer s responsibility to uphold the community s directives. ABB s commitment to the directives ABB Low Voltage Apparatus producing companies will attach the CE mark in accordance with the product directives. Our products will conform as follows: Declarations of conformity for ABB products will be available when required by the relevant EU directives. Those products required to do so will bear CE marking as specified by the relevant EU directives and CE marking regulations. Necessary technical documentation will be on file and made available to authorized organizations upon written request. 1 Approvals listed may not apply to products listed in this publication. 5.6 ABB Control Inc.

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Softstarters Type PSR

Softstarters Type PSR Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

SMC -3 Specifications

SMC -3 Specifications Technical Data SMC -3 Specifications Bulletin Number 150 Topic Page Product Overview 2 Standards Compliance and Certifications 2 Features 3 Catalog Number Explanation 4 Wiring Diagrams 6 General Specifications

More information

Catalog January. Heavy industrial power applications Motor contactors and starters

Catalog January. Heavy industrial power applications Motor contactors and starters Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type

More information

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: advanced soft start and soft stop control protection functions that operate even when

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fire pumps

More information

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB. Latest updated 2010-02-23 not printed, only in PDF-format

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB. Latest updated 2010-02-23 not printed, only in PDF-format Main Catalogue Latest updated 2010-02-23 not printed, only in PDF-format Softstarters Type PSR Type PSS Type PST/PSTB Catalogue 1SFC132004C0201, Edition 7 February 2010 (1SFC132198F0001) News Functionality

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D 40 16 E 0 VD00

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D 40 16 E 0 VD00 Soft Starter Three Phase General Purpose Soft Starters Type RSGD Soft starting and soft-stopping of 3-phase squirrel cage motors 45mm wide IP20 housing Operational Voltage: RSGD40 (220-400V), RSGD60 (220-600V)

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

Reduced Voltage Starters Section 2

Reduced Voltage Starters Section 2 Reduced Voltage Starters- ASTAT XT Soft Starter Description and Features...2-2 Product Number Configuration...2-3 NEMA and IEC Ratings...2-4 Technical Specifications...2-5 Functions...2-6 Overload Protections,

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930 Description Firetrol FTA1930 Digital Solid State Starting Fire Pump Controllers feature soft start, soft stop and

More information

Softstarters. Index. 5 - Softstarters. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com.

Softstarters. Index. 5 - Softstarters. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com. Index 5 5 - General information... 5.1 Softstarter overview...5.2-5.3 Applications...5.4-5.5 PSR - The compact range Description...5.7-5.8 Overview... 5.9 Ordering details... 5.10 Accessories... 5.11 Technical

More information

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES

SECTION 26 29 23 VARIABLE FREQUENCY DRIVES SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Description Wide rated operational voltage 208 690 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 30 to 1050 A (Up to 1810 A inside delta) Wide ambient temperature

More information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

Installation and Maintenance manual. Softstarters PST / PSTB

Installation and Maintenance manual. Softstarters PST / PSTB Installation and Maintenance manual Softstarters PST / PSTB Installation and maintenance PST30... PST1050 manual PST30...PSTB1050 Installation and maintenance manual Introduction... 1.1-1.3 1 Quickstart...

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Products and solutions for pumping, irrigation and piping

Products and solutions for pumping, irrigation and piping Products and solutions for pumping, irrigation and piping 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

August 2004. www.danahermotion.com SECO DC DRIVES. Table of Contents

August 2004. www.danahermotion.com SECO DC DRIVES. Table of Contents SECO DC DRIVES SECO AC/DC DC Drives DRIVES Table of Contents August 2004 www.danahermotion.com Tel : 800 554 8466 Web site : www.danahermotion.com Mechanical and Electro-Mechanical Product Solutions by

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

Sentron Series Circuit Breakers

Sentron Series Circuit Breakers Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electrical Symbols and Line Diagrams

Electrical Symbols and Line Diagrams Electrical Symbols and Line Diagrams Chapter 3 Material taken from Chapter 3 of One-Line Diagrams One-line diagram a diagram that uses single lines and graphic symbols to indicate the path and components

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Bolted contact switches. Pringle switches

Bolted contact switches. Pringle switches Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

PowerFlex 700 and 700H Packaged Drives. Technical Data

PowerFlex 700 and 700H Packaged Drives. Technical Data PowerFlex 700 and 700H Packaged Drives Technical Data Overview The heart of every PowerFlex 700/700H packaged drive package is a PowerFlex Adjustable Frequency Drive. The packaged drives program provides

More information

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Panorama. Softstarters The complete range

Panorama. Softstarters The complete range Panorama Softstarters The complete range Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting

More information

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... ..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Softstarters Type PSE18...PSE370 Installation and commissioning manual

Softstarters Type PSE18...PSE370 Installation and commissioning manual Softstarters Type PSE18...PSE370 Installation and commissioning manual PSE 18-600-70 PSE 18-600-70 PSE 18-600-70 This manual belongs to: 2 Softstarters Type PSE18...PSE370 Installation and commissioning

More information

Operation and Maintenance manual. fusible shunt trip switch

Operation and Maintenance manual. fusible shunt trip switch Operation and Maintenance manual fusible shunt trip switch Table of Contents Fusible Shunt Trip Switch Device Overview... 2 Installation Instructions... 3 Catalog Number Selection Table... 4 Motor Fuse

More information

Products and solutions for machine builders (OEM) 100% electricity

Products and solutions for machine builders (OEM) 100% electricity Products and solutions for machine builders (OEM) 100% electricity www.lovatoelectric.com Tra dition and innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters

More information

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin

More information

32VFD Variable Frequency Drives for Centrifugal Chillers

32VFD Variable Frequency Drives for Centrifugal Chillers 32VFD 32VFD Variable Frequency Drives for Centrifugal Chillers ENERGY-SAVING CONTROL FOR CENTRIFUGAL CHILLERS Reduce energy consumption in your existing centrifugal chiller Your chiller was specified to

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE WHITE PAPER WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE EXPLANATION AND ASSISTANCE FOR APPLYING SOLID STATE SOFT STARTERS IN TRADITIONAL REDUCED VOLTAGE APPLICATIONS Introduction..............................................................2

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

Products and solutions for lifting systems

Products and solutions for lifting systems Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded

More information

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings Smart Frame Wiring Diagrams and Dimensional Drawings Smart Frame Size 60 Vac:.5-7.5 HP 08/0 Vac: 0.75- HP SPECIFICATION DATA CONTENTS Smart Frame Wiring Diagrams... Frame, Fused Disconnect Wiring Diagrams...

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Softstarters. Type PST30...PSTB1050 Installation and Commissioning Manual. Manual 1SFC132003M0201 June 2007. Fault. Power on Protection

Softstarters. Type PST30...PSTB1050 Installation and Commissioning Manual. Manual 1SFC132003M0201 June 2007. Fault. Power on Protection Power on Fault Protection Power on Fault Protection Power on Fault Protection Power on Protection Fault Power on Protection Fault Softstarters Type PST30...PSTB1050 Installation and Commissioning Manual

More information

SMC FLEX QUICK START BULLETIN 150

SMC FLEX QUICK START BULLETIN 150 QUICK START SMC FLEX BULLETIN 0 This guide provides you with the basic information required to start up your SMC Flex controller. When reading this document, look for this symbol Step x to guide you through

More information

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations 12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Single Phase Soft Starter

Single Phase Soft Starter Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY PowerGate - Cost effective solutions for F 1 Horsepower Rating 001 1-40 HP (208V) 075 1-75 HP (480V) Input Voltage 2V 208-240V 4V 380-480V Disconnect

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional

More information

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Comparison of NEMA and IEC schematic diagrams

Comparison of NEMA and IEC schematic diagrams Cross-Reference MZ081001EN Comparison of NEMA and IEC schematic diagrams General With the increasing emphasis on globalization, many industries are now looking to all parts of the world to produce, market,

More information

Speed Control Relays SX2

Speed Control Relays SX2 SX2 File 850 CONENS Description.....................................................Page General Information................................................ 2-3 SX2DV General Information...........................................

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5 Eaton Wiring Manual / Page Overview - ON-OFF switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-Speed Switches - Interlock

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2

PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2 PDS-375-TR Touring CB Power/Data Supply Operator s Manual Rev 1.2 2005 City Theatrical, Inc. Patent Pending The PDS-375 TR Power Supply page 2 CONTENTS The City Theatrical PDS-375 TR...3 Cautions...3 Compliance