1 Data Highway Plus ( Hose ) The Data Highway Plus (DH+) network is a local area network that is very simple to implement. It is designed to provide simple communication between PLC's, SLC's and PC's. The Data Highway Plus network allows connection to a maximum of 64 devices per link although 5 or fewer nodes are recommended per link. Devices include: PLC-5 and SLC 5/04 programmable controllers Color graphics systems Personal computers Host computers Numerical controls Programmable RS-232-C/RS-422 devices A network can be configured with 99 links. With a multi-link network, more nodes in the network are possible. By placing nodes in the proper link with some nodes and separate from other nodes, the efficiency of message delivery can be improved. Using simple twisted-pair wiring, DH+ can be configured as a trunk-line drop or a daisy-chain topology. H
2 Industrial Automation Data Highway Plus ( Hose ), Cable Specifications Hose is a shielded, twisted pair network cable. The cable consists of blue, clear and shield wires. A terminating resistor must be attached across the blue and clear wires at each end of the network. The resistor value depends on the baud rate selected. The cable shield must be connected to chassis ground only at the scanner end of the network. Jacket Figure A Drain Wire Clear Aluminum Foil-Polyester Tape Tinned-Copper Braided Shield Jacket Inner Jacket Figure B Drain Wire Clear Armor Baud Rate Maximum Cable Length 57.6 Kbps 0,000 feet (3048 meters) 5.2 Kbps 5,000 feet (524 meters) Kbps 2,500 feet (762 meters) Type Approvals Data Pair Outer Jacket Shields Bulk Cable AWG DCR (/000 feet) Material Color Type Part Number / Color Code Insulation Nominal O.D. Drain Wire Weight/300 M Figure 390 AWM C 300 Volts NEC CC CL2 CEC CC 2/20 AWG BU, Clear 9.5 Ohms PC PC 6 CC (.238 in) Braid/Coil 20 AWG RB557-*M 36 lbs. A 39A 60 C 300 Volts NEC CC CL2 CEC CC CCG FT4 [HLBCD] 2/20 AWG BU, Clear 9.5 Ohms PC Aluminum Armor/PC Armor Foil Braid RB599-*M 22 lbs. armorfast B * Indicates length in meters. Hose is a registered trademark of Belden CDT Inc. Standard cable lengths are.0, 2.0, 4.0, 6.0, Meters. Consult factory for other lengths. H2
3 Data Highway Plus ( Hose ), Cable and Cordset Selection Matrix eurofast eurofast Bulkhead Pin (Male) Socket (Female) Pin (Male) Socket (Female) RSC WSC RKC WKC FSFD FKFD RSC 39x-*M WSC 39x-*M RKC 39x-*M WKC 39x-*M FSFD 39x-*M FKFD 39x-*M Bare Pin (Male) 3 RSC RSC RSC 39x-*M RSC WSC 39x-*M RSC RKC 39x-*M RSC WKC 39x-*M RSC FSFD 39x-*M RSC FKFD 39x-*M WSC WSC 39x-*M WSC RKC 39x-*M WSC WKC 39x-*M WSC FSFD 39x-*M WSC FKFD 39x-*M eurofast Socket (Female) 2 4 WSC RKC RKC RKC 39x-*M RKC WKC 39x-*M RKC FSFD 39x-*M RKC FKFD 39x-*M WKC WKC 39x-*M WKC FSFD 39x-*M WKC FKFD 39x-*M WKC See page H4 for dimensional drawings. * Indicates length in meters. x Indicates cable type. For armorfast cable: Change part number (RSC RSC 39-*M to RSA RSA 39A-*M) For stainless steel connectors: Change part number (RSC RSC 39-*M to RSCV RSCV 39-*M) Refer to the Cordset Builder at for assistance with cordset/cable combinations. Standard cable lengths are.0, 2.0, 4.0, 6.0, Meters. Consult factory for other lengths. eurofast Pinouts eurofast Male. Drain (Shield) 2. Clear (RI0 #2) 3. (RI0 #) 4. N/C 5. N/C Female H3
4 Industrial Automation Data Highway Plus ( Hose ), eurofast Cordset and Receptacle Connector Dimensions Specifications Housing: PUR (polyurethane) Coupling Nut: Nickel-Plated CuZn or Stainless Steel Contact Carrier: TPU (polyurethane or POM (Nylon) Contacts: Gold-Plated CuZn Protection: NEMA, 3, 4, 6P and IEC IP 68 Rated Voltage: 250 V Rated Current: 4A Ambient Temperature: -30 C to +75 C 2 RSC.. RKC WSC.. WKC FSFD.. FKFD.. RSA.. (armorfast only) RKA.. (armorfast only) H4
5 Notes J
DeviceNet, Gender Changers and Elbow Connectors
DeviceNet, Gender Changers and Elbow Connectors Allows Quick and Easy Changes from to Connectors Available in Straight and Right Angle Styles with minifast Connectors Housing Part Number Specs Application
More informationDeviceNet, Panel Mount Junction Box
DeviceNet, Panel Mount Junction Box DIN Rail Junction Box Open Style Removable Terminals Part Number Application Wiring Diagrams JRBS-57-4 JRBS-57-6 Open style DIN mounted junction box JRBS-57-8 Specifications
More informationDeviceNet, minifast Conduit Adapters
DeviceNet, minifast Conduit Adapters Gasket and Mounting Screws Provided Same Housing Style for Single or Double Port Housing Part Number Specs Application Pinout BCA 57-M123 conduit body* for transition
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationUNITRONIC Data Communication Systems
Data Communication Systems 156 DeviceNet 162 PROFIBUS 168 CAN Bus 184 RS485/RS422 190 AS-Interface 191 Data Highway 194 Interbus 195 Genius 197 CC-Link 198 FOUNDATION Fieldbus 200 Sensor & Actuator Wiring
More informationTimes Microwave Systems Hermetically Sealed Assemblies
SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationAC 800M EtherNet/IP DeviceNet Installation
AC 800M EtherNet/IP DeviceNet Installation System Version 6.0 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Installation System Version 6.0 NOTICE This document contains information
More informationCOAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
More informationDIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationStandards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
More informationIMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
More informationUsing installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
More informationULTIMATE SNAP-N-SEAL
ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design
More information* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...
TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4
More informationData Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
More informationServo Motor & Drive Cables
Servo Motor & Drive Cables Servo-Motor & Drive Cable Contents Servo-SM (Servo-Motor & Feedback Cables to Siemens Specifications) 970 SERVO-SM5-6FX5008-1BD.. UL/CSA/CE SHLD PVC Feedback Cable- Green 971
More informationRoHS DATA, COAXIAL AND ELECTRONIC M.R. D A TA, C O A X I A L, ECOLGICAL Telecom Cables A N D EL E CTRON I C. Cables
RoHS DATA, COAXIAL AND ELECTRONIC D A TA, C O A X I A L, A N D EL E CTRON I C Cables Index SOLID MULTI-CONDUCTOR CABLES STRANDED MULTI-CONDUCTOR CABLES SPEAKER/ZIP WIRE THERMOSTAT CABLE FIRE ALARM CABLE
More informationRGB Component Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex Type
B R I L L I A N C E B R O A D C A S T C A B L E S 19.69 RGB Coponent Video Cable Bundled RGB Coaxial Cables Miniature and High-Flex RGB coaxial cables are used for sending red, green and blue signals through
More informationJack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes
BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can
More informationCable Specifications. T3 Trunk Cabling APPENDIX
APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External
More informationROLINE THE Difference
ROLINE THE Difference The products of the brand ROLINE are developed for professional users and differ in their quality substantially from comparable products in the IT environment. The high compatibility
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationOutdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
More informationOutdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof
Datasheet Outdoor Carrier Class Shielded Ethernet Cable Models: PRO, CARRIER, Connectors Increase Performance Extreme Weatherproof ESD Damage Protection Extended Cable Support 1 2Datasheet Protect your
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationAnalog Multi-Pair Snake Cable High-Flex and NEC Rated Cables
B R I L L I A N C E B R O A D C A S T C A B L E S 19.16 High-Flex and Rated Cables Especially designed for the broadcast industry, Belden s full faily ulti-pair audio Snake cables feature options and construction
More informationGold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN)
Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN) January 2014 (Ver. 1.000) Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information
More informationCIR. Index. Gexol. Standard CIR UL Listed Type TC-ER. Crush and Impact Resistant Without External Armoring. Arctic CIR UL Listed Type TC-ER-HL*
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Available in Standard and Arctic Grade Jackets n Highly
More informationStandard Buccaneer - USB
IP68 rated USB version 2.0 performance Plug and play capability Visual mating indication Shielded system Single and double ended cables Screw coupling PCB versions Dust and waterproof sealing when mated
More informationSealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
More information" EXCEEDING EXPECTATIONS WITH PERFORMANCE "
" EXCEEDING EXPECTATIONS WITH PERFORMANCE " Broadcast Cable Video Sales and Ordering Information: -800-245-4964 Technical Questions: E-Mail us at info@westpenn-cdt.com Sales Department: E-Mail us at wpwsales@westpenn-cdt.com
More informationGexol. Gexol. The Global Cable Solutions Company. Designed for safe, reliable performance in the harshest oil and gas operating environments
Gexol Gexol World Class World Class Designed for safe, reliable performance in the harshest oil and gas operating environments Power Control Instrument VFD The Global Cable Solutions Company Gexol World
More informationSpecification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
More informationSerial Data Grade Cables
VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Authorized Distributor Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored
More informationHSG Engineering Tech Bulletin
Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for
More informationTen Port Multi-Band Antenna
DATA SHEET Eight High Broadband ports simultaneously covering PCS, AWS / AWS-3 and WCS bands Eight High Broadband ports with two Low Band ports in one antenna Excellent elevation side-lobe performance
More informationOptions for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
More informationCommunication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
More informationIMVIB. Online vibration monitoring for Ariel compressors
IMVIB Online vibration monitoring for Ariel compressors The cost-effective way to add spectral vibration measurement & trending on critical machinery Monitoring vibration trends of your industrial equipment
More informationOutside Telephone Cable
Outside Telephone Cable Filled Core. Moisture Barrier. Description Soft copper wires insulated with high density polyethylene, foam skin or solid. Filled core, conformed by groups of pairs or by unit of
More informationWhy FOUNDATION Fieldbus?
Product Bulletin PB 244-R3 Fieldbus Cables Fieldbus Tye A cables rovide installation flexibility in many different environments, including outdoors and where multile or extended cable runs are required.
More informationInstrumentation Cable...14-17. Power Cable...2-11. Assembly Solutions...32
Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant Assemblies...3-33 Ester Based Mud
More informationSUBJECT: NO MORE 300 VOLTS IN PLTC PRINT LEGEND
Belden Electronics Division P.O. Box 1980 Richmond, Indiana 47375-1980 2200 U.S. Highway 27 South Richmond, Indiana 47374-7279 Telephone: 765 983 5200 Facsimile: 765 983 5825 SUBJECT: NO MORE 300 VOLTS
More informationSystem Wiring Design Guide
System Wiring Design Guide This guide will help demonstrate the various types of wiring solutions available when connecting video surveillance cameras to EZ Watch Pro and Armor Pro Digital Video Recorders.
More informationThe Wild Children of D38999
micro38999 Series High Vibration Miniature Connectors The Wild Children of D38999 A complete range of space saving compact connectors with all of the features and capabilities of D38999 for harsh applications.
More informationA quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies
A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies Select, Customize, Order & Receive Products with Ease This catalog contains
More information1394 locking cables. Your locking cables for AVT IEEE 1394 cameras
Your locking cables for AVT IEEE 1394 cameras AVT locking cables are ideal for connection of IEEE 1394 cameras in any industrial application. The high quality cables guarantee low damping and best signal
More informationCopper Cabling Infrastructure Offering
Copper Cabling Infrastructure Offering High-Speed Copper Cabling Systems The deployment of high speed cabling systems has been increasing rapidly as data centers enable their physical infrastructure with
More informationEXCELLENCE. LAPP SYSTEMS CAPABILITIES DESIGN AND FABRICATION OF POPULATED CABLE TRACK FULL ENGINEERING DESIGN AND DOCUMENTATION INCLUDING CAD DRAWINGS
EXPECT EXCELLENCE. With a heritage dating back to 1996, Lapp Systems USA was established with the merger of OLFLEX & Contact Electronics Systems groups. Today, with over 15 years of combined experience,
More informationC 060 CCTV Coaxial Cable
C 060 CCTV Coaxial Cable These cables are used for video transmissons of CCTV applications..4...... Coaxial Cable (C 060).. Inner Conductor : Ø 0.60 mm Bare Copper.. Insulation : Ø.80 mm Gas-injected Foam
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationData Highway/Data Highway Plus/ Data Highway II/Data Highway 485 Cable Installation Manual
Installation Manual Because of the variety of uses for this product and because of the differences between solid state products and electromechanical products, those responsible for applying and using
More informationGold Cello Gold Cello Cable Kit
Gold Cello Gold Cello Cable Kit January 2014 (Ver. 1.101) Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information belonging to Elmo
More information15 Pin DSUB - MALE 15 Pin DSUB - FEMALE 9 Pin DSUB - MALE 9 Pin DSUB - FEMALE
Last Revised: 3 Oct 03 Description: This data sheet show our range of high quality appliance cables, such as signal cables (VGA / DVI), Touchscreen and power cables. These are either delivered with our
More informationNetwork Connectivity. Your link for dependable routing of signal and data in industrial environments
Network Connectivity Your link for dependable routing of signal and data in industrial environments LynxPOWER Industrial Connectivity Realize time and cost savings with LynxPOWER Industrial Connectivity
More informationM-Bus Network Installation Notes
M-Bus Network Installation Notes 1 M-Bus Network Installation Notes This manual explains how to calculate the maximum M-Bus cable length depends on technical parameters of used cable and number of M-Bus
More informationMICROCABLES. A complete vision of your connectivity needs. Catalogue
MICROCABLES A complete vision of your connectivity needs Catalogue ELECTRONIC Filotex Introduction Application Nexans s line of microcables is designed towards the increasing requirements of electronics
More informationMICRO SFP+ CONNECTOR & CABLE ASSEMBLY
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.
More informationWe hope that every customer sets up CC-Link system easily by reading this documentation.
This documentation describes items to consider in advance, how to select devices, points to keep in mind and procedure in order to set up cable wiring. Abstract of contents Chapter 1: Procedure for cable
More information6000 Series Buccaneer
Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationTechnical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
More informationTechnical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationLED...A70..4-..Q Series Sealed High-Intensity
LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for
More informationDL AND DBA SERIES CONNECTORS QUALIFIED TO MIL-DTL-83723 SERIES III Weight-saving aluminum connectors designed for rugged use and high temperatures
DEUTSCH DL AND DBA SERIES CONNECTORS QUALIFIED TO MIL-DTL-83723 SERIES III Weight-saving aluminum connectors designed for rugged use and high temperatures DEUTSCH DL AND DBA SERIES CONNECTORS Weight-saving
More informationBackup Scanner Module
Backup Scanner Module Catalog Number 1747-BSN Installation Instructions 2 Backup Scanner Module Important User Information Because of the variety of uses for the products described in this publication,
More information600V Power Cable 600V SOOW SOW
600V Power Cable Type SOOW UL/CSA 90 C 600V Part AWG No of Insulation Jacket Nominal Wieght/Mft Number Stranding conductors Thickness Thickness O.D. Nom. 18 2 SOOW 18 AWG 2.30 71 18 3 SOOW 16/.010 3.030
More informationWhat is BACnet MS/TP?
and Wiring Installation Guide CARRIER CORPORATION 2014 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-461-01 8/5/2014 Verify that you have the most current version
More informationTURCK Modular Industrial I/O PROFIBUS -DP Products
TURCK Modular Industrial I/O PROFIBUS -DP Products Piconet Gateways Rugged, Fully Potted Stations IP 67 Protection Small Footprint Automatic Baud Rate Sensing SDPL-0404D-0003 SDPL-0404D-0004 SDPL-0404D-1003
More informationTFC/U-JIN Coaxial Cable Product Information Sheet Type: TU6T60-JVB
Type: TU6T60-JVB Dielectric 2nd Outer (w/optional Floodant) Series 6 Coaxial Cable Copper Clad Steel Foamed Polyethylene Dielectric Bonded AP Laminate Shield 60% Aluminum Braid "Life Time" compound AP
More informationUnderstanding Shielded Cable
Understanding Shielded Cable Industrial applications such as the factory floor are typically electrically noisy environments. Electrical noise, either radiated or conducted as electromagnetic interference
More informationADACSNET USB Control Module
ADACSNET USB Control Module Installation Guide Termination Switch 2-Pin SensorNet Connection Features and Hookup The USB Control Module contains the following: - USB port: Connects to the host computer.
More informationEMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
More informationAccelerating Light. Copper Cabling Solutions. Category 6A
Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity
More information100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationMicrophone and Musical Instrument Cable Overview
B R I L L I A N C E B R O A D C A S T C A B L E S 19.3 Microphone and Musical Instruent Cable Overview Flexible Microphone Cables Belden icrophone cable is used for connecting low level icrophones or usical
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationSchneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0
Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting
More informationCoaxial Cable Solutions Guide
Coaxial Solutions Guide General offers a complete line of Carol Brand Coaxial s for today s sophisticated high-speed, wide-bandwidth electronics products that run over long distances with minimal signal
More informationRS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
More informationIndustrial Ethernet Media. Complete Solution for Ethernet Networks and Integrated Architecture
Industrial Ethernet Media Complete Solution for Ethernet Networks and Integrated Architecture Product Spotlight Ethernet networking is a growing solution for industry applications, and Rockwell Automation
More informationDeviceNet Media. Design and Installation Guide
DeviceNet Media Design and Installation Guide Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for
More informationWest Penn Wire. Access Control Systems and Cables WEST PENN WIRE CABLE WITH CONFIDENCE
West Penn Wire Access Control Systems and Cables Access Control Cables AWG Size CARD READER CABLES # of Cond. CMR Shielded CMP Shielded CMR Unshielded CMP Unshielded 22 4 3241 253241B 241 25241B 22 6 3270
More informationFrame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.
A P P E N D I B Cabling Summary Introduction This appendix contains details on the MG 8850 cabling. Note In all cable references, the transmit direction is away from the switch, and the receive direction
More informationWxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
More informationFIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
More informationBURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
More informationComtrol Cable User Guide
Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered
More informationErrors Related to Cable Resistance Imbalance in Three Wire RTDs
Errors Related to Cable Resistance Imbalance in Three Wire RTDs 1.0 Introduction There are multiple sources of error that can impact the accuracy of an RTD measurement. The cable incorporated into the
More informationCabling Specifications
APPENDIX A This appendix provides cabling and pinout information for feature cards on the Cisco AS5350XM and Cisco AS5400XM universal gateways. It contains the following sections: 2-Port and 4-Port T1
More informationSet for Profibus DPV1 in IP20 TI-BL20-DPV1-8
Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
More informationElectro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
More information6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding
circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More information