PERFORMANCE SPECIFICATIONS

Size: px
Start display at page:

Download "PERFORMANCE SPECIFICATIONS"

Transcription

1 Specifications 530T Series Electronic Gauge Pressure Transmitter With Remote Seal Elements Operates at Full Vacuum ±0.2% of span accuracy Spans from 10 psig to 2000 psig Outstanding temperature stability All-welded remote seal design 7-year warranty The 530T Series Remote Seal Electronic Gauge Pressure Transmitter is a two-wire, 24V dc transmitter with a 4 to 20 ma dc output signal linear to the input pressure. The transmitter employs a ceramic capacitance sensor and unique, hermetically sealed, thick-film hybrid circuit. Each hybrid circuit is dynamically laser trimmed to match the performance characteristics of the sensor to create a high-performance, high-reliability transmitter. Combined accuracy, temperature, and pressure stability are unmatched by other electronic pressure transmitters. SPANS AND RANGES Transmitter Span Limits Range Limits Maximum Working Minimum & Maximum Lower Upper Pressure (MWP)* 532T 10 psig to 40 psig psig 40 psig 120 psig (70 kpa) to (275 kpa) (-100 kpa) (275 kpa) (825 kpa) 533T 40 psig to 160 psig psig 160 psig 480 psig (275 kpa) to (1,100 kpa) (-100 kpa) (1,100 kpa) (3,300 kpa) 534T 150 psig to 600 psig psig 600 psig 1500 psig (1,050 kpa) to (4,200 kpa) (-100 kpa) (4,200 kpa) (10,000 kpa) 535T 500 psig to 2000 psig psig 2000 psig 2000 psig (3,500 kpa) to (14,000 kpa) (-100 kpa) (14,000 kpa) (14,000 kpa) * Overpressure Limit is that given or seal MWP, whichever is less. Zero Elevation/Suppression: Zero is infinitely adjustable provided that the calibrated range is within the span and range limits above. Warranty: ABB Instrumentation Inc., Rochester, NY, warrants the 500T Series Transmitter for 7 years from date of shipment. Contact ABB Instrumentation Inc., for complete information PERFORMANCE SPECIFICATIONS Electrical Classification Agency approvals and certifications as listed in Ordering Information. Also see Specification Sheet Temperature Limit Process Silicone 2 702A Fluid: -13 to 400 F (-25 to 204 C) Water/Glycerine: 20 to 200 F (-7 to 93 C) Silicone 702B Fluid: 20 to 600 F (-7 to 316 C) Ethylbenzene: 100 to 200 F (73 to 93 C) Fluorolube 3 : 0 to 250 F (-18 to 121 C) Ambient (Also, see 8 th character of ordering information) Without Digital Output Meter: -13 to 185 F (-25 to 85 C) With Digital Output Meter: -13 to 149 F (-25 to 65 C) Storage Without Digital Output Meter: -65 to max. ambient + 15 F (-54 to max. ambient C) With Digital Output Meter: -65 to 149 F (-54 to 65 C) Service Liquid, gas, or steam Vacuum Service Full Vacuum ABB Instrumentation SS T-169

2 Operating Voltage (Transmitter) Maximum Without Options With Surge Protection With Digital Output Meter With All Options Minimum Without Options With Surge Protection With Digital Output Meter With All Options Load Limitations* Drive Impedance Supply V dc - Minimum V dc Maximum Drive Impedance Without Options With Surge Protection With Digital Output Meter With All Options Relative Humidity 0 to 100% RH 12V dc 13.4V dc 16.0V dc 21.9V dc 1650 ohms 1580 ohms 1450 ohms 1150 ohms Remote Seal** Wafer Element For installation on 1-1/2 in., ANSI, raised face flange. MWP in lower of the overpressure limit or rating of back-up flange. Union Connection Element Without Fitting 1500 psig ( kpa) MWP or overpressure limit, whichever is less Union Connection Element With Welding Bushing 1500 psig ( kpa) MWP or overpressure limit, whichever is less Union Connection element With Chemical Tee Flange 300 psig (2000 kpa) MWP or overpressure limit, whichever is less Vavuum Service Full Vacuum * For higher load capability, contact Rochester. ** All elements have low-pressure limit of 0 psia (0 kpa abs) provided seal element is at or above level of capsule. See Note 2 after Ordering Information. All welded construction permits operation at full vacuum depending on installation and fill fluid. PERFORMANCE SPECIFICATIONS Accuracy (Includes effects of linearity, hysteresis, and repeatability) ±0.2% of calibrated span Hysteresis and Dead Band Combined Better than 0.05% Repeatability Better than 0.05% Ambient Temperature Effect Temperature effect on performance of remote seal transmitters is dependent on many factors such as: Process temperature Ambient temperature Sunshine vs shade on capillary length of capillary Type of seal element Capillary Fill fluid Calibrated span of unit Amount of suppression or elevation Under controlled conditions, temperature effect is less than 1.0% per 100 F (56 C) Overpressure Effect ±0.25% of upper range limit (URL) on zero Optional Surge Protection Up to 2500V pulse (5K amp discharge current) of 8µs rise time and 20 µs decay to half value Output Signal 4 to 20 ma dc Long-Term Stability Better than ±0.25% of URL after 6 months Supply Voltage Effect Less than 0.005% per V dc Load Effect None PHYSICAL SPECIFICATIONS Vibration Effect ±0.1% URL/2g at 15 to 150 Hz ±0.1% URL/g at 151 to 2000 Hz RFI Effect Meets SAMA Standard PMC Tested over a full frequency range of 20 to 1000 MHz. Process Diaphragm Choice of: Type 316L SST Hastelloy C 4 alloy Tantalum (available with Wafer Seal Element only) Fill Fluids Primary Silicone 1 Seal and Capillary Choice of: Silicone 702A Fluorolube 2 Silicone 702B Water/Glycerine Ethylbenzene Capillary 304 SST capillary with spiral armor protection and polyethylene jacket Transmitter Housing Low copper cast aluminum with baked epoxy ester, urea formaldehyde melamine finish; NEMA 4X, CSA Enc 4, IP66 NACE (National Association of Corrosion Engineers) Interpretation of NACE Specification MR-01-75, latest Revision, is that it applies only to process-wetted parts. NACE qualified selections are clearly identified under Ordering Information. Weight Basic Transmitter: 6.1 lb (2.8 kg) Seal Elements: Add 1.5 to 5.9 lb. (0.7 to 2.7 kg) Electrical Connection 1/2 in. Int. NPT For Electrical Codes 08 and 38 only, 2 each, 1/2 in. NPT male x M20 female adapters are provided. For Electrical Code 82 only, 2 each environment-resistant circular connectors with angle plug, per MIL-C-5015, are provided. SS T-170

3 SS T-171

4 ORDERING INFORMATION 530T SERIES ELECTRONIC GAUGE PRESSURE TRANSMITTER WITH REMOTE SEAL ELEMENTS 1. Select one character or set of characters from each category and specify complete catalog number per sample below. 2. Specify tagging if required. Tagging information is provided on the exterior stainless steel data plate to a limit of 40 characters. 3. Specify calibration in psi or kpa. Code No. 532T 533T 534T 535T Description BASE NUMBER - 1st thru 4th characters Electronic Gauge Pressure Transmitter with Remote Seal Elements, Span adjustable from 10 to 40 psi (70 to 275 kpa) Electronic Gauge Pressure Transmitter with Remote Seal Elements, Span adjustable from 40 to 160 psi (275 to kpa) Electronic Gauge Pressure Transmitter with Remote Seal Elements, Span adjustable from 150 to 600 psi (1 050 to kpa) Electronic Gauge Pressure Transmitter with Remote Seal Elements, Span adjustable from 500 to 2000 psi (3 500 to kpa) PRIMARY FILL-FLUID - 5th character D Silicone 1 ELECTRICAL CODE - 6th and 7th characters (also see Specification Sheet 12-16) 01 FM Approved: Non-Incendive (Division 2), Explosionproof (Division 1), Intrinsic Safety (Division 1) 02 BASEEFA Certified: Type N (Zone 2), Intrinsic Safety (Zone 0) 04 CSA Certified: Non-Incendive (Division 2), Explosionproof (Division 1), Intrinsic Safety (Division 1) 08 SAA Certified: Type N (Zone 2), Flameproof (Zone 1), Intrinsic Safety (Zone 0) 10 General Purpose, ABB Instrumentation Standard 31 FM Approved: Non-Incendive (Division 2), Explosionproof (Division 1) (Note 1) 32 BASEEFA Certified: Type N (Zone 2) (Note 1) 34 CSA Certified: Non-Incendive (Division 2), Explosionproof (Division 1) (Note 1) 38 SAA Certified: Type N (Zone 2), Flameproof (Zone 1) (Note 1) 45 BASEEFA Certified: Flameproof (Zone 1) 82 BASEEFA Certified: Intrinsic Safety (Zone 0) (Electrical Connection includes Environment Resistant Circular Connector with Angle Plug per MIL-C-5015) CAPILLARY FILL-FLUID AND SEAL ELEMENT TEMPERATURE RANGES - 8th character 1 Silicone 702A; Process: -13 to 400 F (-25 to 204 C) (Note 2); Ambient: 10 to 135 F (-12 to 57 C) (Note 5) 2 Water/Glycerine; Process: 20 to 200 F (-7 to 93 C) (Note 3); Ambient: 20 to 185 F (-7 to 85 C) 3 Silicone 702B (not available with 18 th character 1); Process: 20 to 600 F (-7 to 316 C) (Note 2); Ambient: 20 to 120 F (-7 to 49 C) (Note 5) 4 Ethylbenzene; Process: -100 to 200 F (-73 to 93 C) (Note 3); Ambient: 20 to 125 F (-7 to 52 C) (Note 5) 5 Fluorolube 2 ; Process: 20 to 250 F (-7 to 121 C) (Note 2); Ambient: 15 to 145 F (-9 to 63 C) (Note 5) SEAL ELEMENT TYPE AND MAXIMUM WORKING PRESSURE (MWP) - 9th character (MWP is lower of Seal Element or Transmitter Span MWP limitations) 1 Wafer Element for Installation on 1-1/2 in. ANSI Raised Face Flange, 2000 psig ( kpa) MWP 5 Union Connection Element without Fitting, 1500 psig ( kpa) MWP (only available with 533T, 534T), maximum 500 F (260 C) 6 Union Connection element with 316 SST Welded Bushing, 1500 psig ( kpa) MWP (only available with 533T, 534T), maximum 500 F (260 C) 7 Union Connection Element with Chemical Tee Flange, 300 psig (2000 kpa) MWP (only available with 533T), maximum 500 F (260 C) SEAL ELEMENT DIAPHRAGM MATERIAL - 10th character 2 Type 316L SST - NACE (not available with Element O-Ring Selection 1) 3 Hastelloy C 7 Tantalum (only available with Seal Element Type 1), maximum 260 C ( 500 F) B MODEL - 11th character Design level 0 UNUSED CHARACTER - 12th character MOUNTING BRACKET - 13th character 1 Bracket for 1-1/4 in. to 2 in. (32 mm to 50 mm) pipe or surface mounting, carbon steel 2 Bracket for 1-1/4 in. to 2 in. (32 mm to 50 mm) pipe or surface mounting, SST (Note 4) SS T-172

5 ORDERING INFORMATION Code No. Description OUTPUT METER - 14th character 1 0 to 100 Linear Scale 3 Digital (see Note 1) OPTIONS - 15th character 2 Surge Protector - HYPHEN - 16th character WAFER ELEMENT BACKUP FLANGE (For use with Wafer Seal Element) - 17th character 1 One 1-1/2 in. ANSI, Class 150, Carbon Steel, Raised Face, Backup Flange with Bolts and Nuts (275 psi at 100 F) (not available on 535T) 2 One 1-1/2 in. ANSI, Class 300, Carbon Steel, Raised Face, Backup Flange with Bolts and Nuts (720 psi at 100 F) 3 One 1-1/2 in. ANSI, Class 1500, Carbon Steel, Raised Face, Backup Flange with Bolts and Nuts (3600 psi at 100 F) UNION CONNECTION ELEMENT O-RING - 18th character (not available with Seal Element Selection 5, 6, or 7) 1 Silicone Rubber (available with Seal Element Selection 5, 6, or 7 only, NOT available with 8 th character 3 or 10 th character 2), maximum 400 F (204 C) 2 Teflon 3 TFE (available with Seal Element Selection 5, 6, or 7 only), maximum 500 F (260 C) CAPILLARY LENGTH - 19th and 20th characters 05 5 ft (1.5m) minimum ft (3m) ft (4.5m) ft (6m) maximum 534TD01112B SAMPLE CATALOG NUMBER NOTES: 1. Electrical Codes 10, 31, 32, 34, 38 and 45 are the only valid codes when a digital output meter (14th character 3) is required. 2. Maximum temperature for full vacuum limit is: 300 F (149 C) for Silicone 702A 350 F (177 C) for Silicone 702B 175 F (80 C) for Fluorolube Consult ABB Instrumentation Rochester for low-pressure limits at higher temperatures. 3. Not for vacuum service. Consult ABB Instrumentation Rochester for low pressure limits. 4. Not available with BASEEFA or SAA electrical code. 5. Listed ambient temperature limits are for maximum capillary length of 20 feet (6m). For shorter capillary length, decrease the minimum and increase the maximum ambient by 1 F (0.55 C) for each foot (each meter x 3.28) below 20 feet (6m). Notes: Minimum ambient can not be less than minimum process. Does NOT apply to water/glycerine. For example, ambient temperature limits for a 5ft (1.5m) capillary length with Silicone 702A are: minimum ambient = 10 F 1 F x 15 ft = 5 F = 12 C (0.55 C x 4.5m x 3.28) = 20 C maximum ambient = 135 F + 1 F x 15 ft = 150 F = 57 C + (0.55 C x 4.5m x 3.28) = 65 C 1 Trademark of Dow Corning Company 2 Trademark of Occidental Chemical Company 3 Trademark of E.I. du Pont de Nemours & Company, Inc. 4 Trademark of Haynes International Inc. SS T-173

6 The Company s policy is one of continuous product improvement and the right is reserved to modify specifications contained herein without notice ABB Instrumentation ABB Kent-Taylor Ltd. ABB Instrumentation Inc. ABB Kent-Taylor SpA St. Neots Cambs. P.O. Box Lenno England, PE19 3EU Rochester, New York Como, Italy Tel: (01480) Tel: (716) Tel: (0344) Fax: (01480) Fax: (716) Fax: (0344) SS T-174 SS

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Ed.15.01 Design Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Standard 4026/60H Pressure rate PN 40

More information

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features GE Measurement & Control Solutions RTX 1000 Series Versatile Transmitters for a World of Pressure GE Measurement & Control Solutions is renowned for the design and manufacture of compact and rugged high

More information

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features GE Measurement & Control STX2100 Differential Pressure (Flow) Transmitter Models FKC...5 The STX2100 differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge

More information

Micro Motion Model D and DL Coriolis Flow and Density Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,

More information

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate

More information

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS EPP - 1 DECRIPTION The odel 575 is used in general water/wastewater applications. The transmitter is offered in a standard non-clogging snub nose end, flush diaphragm or protected flush diaphragm with

More information

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

How To Make A Smart Transmitter

How To Make A Smart Transmitter For Differential/Gauge/Absolute/High Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas 34-XY-03-01, May 2012 Function The WG/A5xx is part of the XYR 5000 family of wireless products.

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals

More information

Baumann 87000 Flexsleev Sanitary Control Valve

Baumann 87000 Flexsleev Sanitary Control Valve Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a

More information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS. Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid

More information

Models SFP33 & SFP32 Pressure Transmitters

Models SFP33 & SFP32 Pressure Transmitters SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100 WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

NDP-50 Specifications

NDP-50 Specifications NDP-50 Specifications Port Dimensions Intake & discharge connection: (164 GPM Max.) Polypropylene (PPG) 2" ANSI B16.5 #150 Kynar (PVDF) 2" ANSI B16.5 #150 Aluminum (ADC-12) 2" ANSI B16.5 #150 (with tapped

More information

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve

Baumann 24003 3 Way Bronze or Stainless Steel Control Valve Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control

More information

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520 CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520 Precise point-of-use chemical flow control innovative flow control technology Overview Entegris is solving today s flow control

More information

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output. Level Plus Magnetostrictive Liquid-Level Sensors with Temposonics Technology M-Series Model MR Transmitter with Analog Output Data Sheet SENSORS Document Part Number 550677 Revision J Features 4 to 20

More information

Baumann 81000 Mikroseal Control Valve

Baumann 81000 Mikroseal Control Valve Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

PRODUCT PROFILE FEATURES

PRODUCT PROFILE FEATURES PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA Mobrey Ultrasonic MSP900SH Level and MSP900FH Flow Transmitters Product Data Sheet February 2015 IP2032, Rev BA Non-contacting measurement with no moving parts Fast and simple to install and configure

More information

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100 Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When

More information

B-Series Switches Pressure, Differential Pressure & Hydraulic

B-Series Switches Pressure, Differential Pressure & Hydraulic FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment

More information

Smart Displacement type Level Transmitter

Smart Displacement type Level Transmitter No. SS-SLX100-0100 Smart Displacement type Level Transmitter Model SLX OVERVIEW The SLX series is a complete line of highly accurate and reliable high-performance torque tube type displacement level transmitters

More information

Rosemount 751 Field Signal Indicator

Rosemount 751 Field Signal Indicator Rosemount 751 Field Signal Indicator Product Data Sheet August 2014 00813-0100-4378, Rev FA Available with an LCD display or analog meter Compact, rugged, and designed for industrial environments Available

More information

The Unique Accelabar Flow Meter

The Unique Accelabar Flow Meter The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Rosemount 1199 Submersible Seal

Rosemount 1199 Submersible Seal Product Data Sheet July 2013 00813-0400-4016, Rev AA The Rosemount Submersible Seal design uses innovative DP level technology to measure level for top-down applications. For this design, the seal and

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Model 3051 Pressure Transmitter with HART Protocol

Model 3051 Pressure Transmitter with HART Protocol Model 3051 Pressure Transmitter with HART Protocol Start Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Configure

More information

Turbine Flowmeters for Gas Applications

Turbine Flowmeters for Gas Applications Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because

More information

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 752 FOUNDATION fieldbus Remote Indicator Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Rosemount DP Level Transmitters and 1199 Diaphragm Seal System

Rosemount DP Level Transmitters and 1199 Diaphragm Seal System Rosemount DP Level Transmitters and 1199 Diaphragm Seal System Product Data Sheet May 2016 00813-0100-4016, Rev RA Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures

More information

9000 Series Accelerometers Specifications

9000 Series Accelerometers Specifications Technical Data 9000 Series Accelerometers Specifications Catalog Numbers EK-43781I, EK-43782I, EK-46255I, EK-45890I, EK-43784I, EK-47086I, EK-43792I, EK-47090I, EK-43799I, EK-43794I, EK-43795I, EK-43797I,

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. GE Measurement & Control UNIK 5800/5900 Flameproof/Explosion-Proof Pressure Sensing Platform The 5800 and 5900 are compact and rugged versions of the high performance UNIK 5000 pressure sensing platform

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Instruction Manual 646 Transducer Fisher 646 Electro Pneumatic Transducer Contents Introduction... 1 Scope of Manual... 1 Description... 3 Specifications... 4 Educational Services... 4 Installation...

More information

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS TECHNICAL BROCHURE BAQUABII * Available up to 1 GPM systems Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS FEATURES The AB2 variable speed pump controller and complete booster package kits, provide

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided

More information

Fisher 657 and 667 Diaphragm Actuators

Fisher 657 and 667 Diaphragm Actuators 657 and Actuators Product Bulletin Fisher 657 and Diaphragm Actuators Fisher 657 and spring-opposed diaphragm actuators position the valve plug in the valve in response to varying controller or valve positioner

More information

In-Line Electronic Flow Switches

In-Line Electronic Flow Switches In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification... OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

OPTIMASS 6000 Technical Datasheet

OPTIMASS 6000 Technical Datasheet OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT

More information

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter Product Data Sheet Rosemount 2088 Rosemount 2088 Absolute and Gage Pressure Transmitter Performance of 0.075% with High Accuracy option Lightweight, compact design for cost effective installation Protocols

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES Precision Gage/Absolute Transducer DESCRIPTION Model TJE pressure transducers are all-welded stainless steel sensors built for rugged industrial applications that require high accuracy and measurement

More information

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms Broad range of flow capacities 2% Full scale accuracy Versatile

More information

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems Data sheet DS/FPD580 EN Rev. B StackFlowMaster FPD58, FPD583 and FPD585 Stack gas metering systems Measurement made easy Flow metering solutions for Continuous Emissions Monitoring (CEMS) Continuous measurement

More information

Times Microwave Systems Hermetically Sealed Assemblies

Times Microwave Systems Hermetically Sealed Assemblies SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves

Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves Features Top guided design offers high capacity with 0.110 in 2 [0.710 cm 2 ] orifice area.

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

SMV 3000 Smart Multivariable Flow Transmitter

SMV 3000 Smart Multivariable Flow Transmitter SMV 3000 Smart Multivariable Flow Transmitter Measurements and Calculations: Differential Pressure Absolute or Gauge Pressure Process Temperature via 100 ohm Pt. RTD or Type J,K,T or E Thermocouple Mass

More information

1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids

1/2 NPTM. 29.21 mm 1.15. Nose cone fitting Ideal for clean liquids PT-500 Submersible Liquid Level Transmitter 1.0 Hex 25.4 mm 7.0 177.8 mm Re-Usable cage fitting Ideal for dirty liquids 5.63 143 mm 5.33 136 mm 1/2 NPTM 3.5 88.9 mm 1.15 29.21 mm Nose cone fitting Ideal

More information

B-Series Temperature Switches

B-Series Temperature Switches FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Differential Pressure Transmitter Model DPT-10

Differential Pressure Transmitter Model DPT-10 Electronic Pressure Measurement Differential Pressure Transmitter Model DPT-10 WIKA Data Sheet PE 86.21 Applications Process engineering Pharmaceutical Food and beverage industries Special features High

More information

AIRMAR. The Latest Evolution in TRIDUCER Multisensor Technology. New THRU-HULL Depth Speed Temperature TECHNOLOGY CORPORATION. Specifications.

AIRMAR. The Latest Evolution in TRIDUCER Multisensor Technology. New THRU-HULL Depth Speed Temperature TECHNOLOGY CORPORATION. Specifications. New THRU-HULL Depth Speed Temperature SECTION 1 Introduction B744V, B744VL,SS544V, B66V, B66VL 50 khz,120 khz, 120 khz Dual Beam, 150 khz, 170 khz, 200 khz, 235 khz, 50/200 khz Dual Frequency, 50 khz &

More information

289 SERIES FLOW METER TRANSMITTERS

289 SERIES FLOW METER TRANSMITTERS 289 SERIES FLOW METER TRANSMITTERS INSTRUCTION MANUAL 289 SERIES TRANSMITTER 289-763 Pickup Coil/Amplifier, Amphenol Connector 289-773 Pickup Coil/Amplifier, Weather-Tight, Explosion-Proof* TABLE OF CONTENTS

More information

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

SOLFRUNT Pressure Gauges and Other Products for the Process Industries A1 SOLFRUNT Pressure Gauges and Other Products for the Process Industries AMETEK s line of high quality process gauges are specifically designed to meet the demanding needs of the chemical and petroleum

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing DuPont FM-200 agent,

More information

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with

More information

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure

More information

550658 D. PARAMETER SPECIFICATION Measured Variable: Displacement

550658 D. PARAMETER SPECIFICATION Measured Variable: Displacement T E M P O S O N I C S L S E R I E S LH 550658 D P r o d u c t S p e c i f i c a t i o n s Temposonics L Series position sensors are available with analog outputs (voltage or current) or digital outputs

More information

needle valves Needle Valves Index At a Glance 1

needle valves Needle Valves Index At a Glance 1 Needle Valves Index At a Glance 1 1700 Series 5 Forged Body, Integral Bonnet Needle Valves 2100 Series 8 Bar Stock, Screwed Bonnet Needle Valves 2200 Series 12 Bar Stock, Screwed Bonnet Needle Valves 2219

More information

Technical Data Sheet. 3DLevelScanner

Technical Data Sheet. 3DLevelScanner Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

Electronic Product Catalog

Electronic Product Catalog Electronic Product Catalog Electronic Product Catalog Pressure Transmitters and Transducers General Purpose Pressure Transmitters Hazardous Area Pressure Transmitters Submersible Liquid Level Transmitters

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters July 10, 2007 - Page 1 Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters General The Bristol 5453-10G indicating pneumatic pressure controller with 624-II control unit, from Emerson

More information

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Dimensions. LUC-M20 with F12 housing and process connection 2 approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions. Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning

More information

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters Data Sheet Brooks Digital MFC's & MFM's Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters GENERAL FEATURES Wide FS flow range for measurement

More information

Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers

Description. Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers Specifications and Ordering Information 330400 and 330425 Accelerometer Acceleration Transducers R Description These accelerometers are intended for critical machinery applications where casing acceleration

More information

OPTIMASS 1400 Technical Datasheet

OPTIMASS 1400 Technical Datasheet OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Series DFMT Digital Paddlewheel Flowmeter

Series DFMT Digital Paddlewheel Flowmeter Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous

More information

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features: GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in

More information