Snow Melting Manifold Summary

Size: px
Start display at page:

Download "Snow Melting Manifold Summary"

Transcription

1 Snow Melting Manifold Summary Date: Jan 2, Flying Cloud Dr., Eden Prairie, MN Phone: Web: Manifold name: Manifold location: Loop number 1 Name SnowMelt1-Lp1 Heated area (ft²) 216 Tube spacing (in) 15. Tube /size 5/8" hepex Distance to manifold (ft) 3 Loop length (ft) 192 Temperature drop ( F) 25. Flow (gpm) 1.2 Head loss (ft H2O) 6.9 Supply temperature ( F) Valve turns from closed SnowMelt1-Lp /8" hepex Open S/R tubing 3/4" hepex Total flow (gpm) 2.6 S/R Tubing length(ft) Total panel output (Btuh) S/R Tubing head loss (ft H2O) Total tubing required (ft) 415 Max loop head loss (ft H2O) 8.77 Total area (ft²) Manifold head loss (ft H2O) 1.56 Total head loss (ft H2O) Feb-24 9:11:32

2 Snowmelting Design Summary Date: Jan 2, Flying Cloud Dr., Eden Prairie, MN Phone: Web: Snowmelt Information Snowfall rate (in/hr):.8 Wind speed (mph): 2 Design temp. ( F): 2 Area name SnowMelt1 Sys. Res Construction Concrete Insul. Full P/up temp. ( F) Resp. time (hrs) 4.7 Heating rate (Btuh/ft²) Melt P/up Dsn Area (ft²) Heat required (Btuh) Totals Hydronic Devices Device Name Device Load (Btuh) Flow (gpm) Head (ft H2O) S/R tubing or Size,Cv SWT Req. ( F) SWT Spld ( F) SysPump2 MixDevice1 PrimPump1 Manifold System Pump Injection Pump Primary Pump /4" hepex 3/4" COPPER 1/2" COPPER 3/4" COPPER Feb-24 9:11:32

3 Project Summary Date: Jan 2, 212 Entire House 1741 Flying Cloud Dr., Eden Prairie, MN Phone: Web: Notes: Proper heat load analysis is the first and most critical step in any space heating or snow melting project. Sample design only. Not for use in the field. Copyright 212 Weather: Winter Design Conditions Design Information Minneapolis-St. Paul, MN, US Summer Design Conditions Outside db -11 F Outside db 88 F Inside db 68 F Inside db 75 F Design TD 79 F Design TD 13 F Daily range M Relative humidity 5 % Moisture difference 24 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 2347 Btuh Structure 6252 Btuh Ducts Ducts Central vent ( cfm) Central vent ( cfm) Humidification Blower Piping 5325 Btuh Equipment load Btuh Use manufacturer's data n Infiltration Rate/swing multiplier.93 Equipment sensible load 5814 Btuh Latent Cooling Equipment Load Sizing Method Simplified Construction quality Tight Fireplaces Structure 3 Ducts Heating Cooling Central vent ( cfm) Area (ft²) Equipment latent load 3 Volume (ft³) Air changes/hour.11.6 Equipment total load 6114 Btuh Equiv. AVF (cfm) Req. total capacity at.7 SHR.7 ton Heating Equipment Summary Cooling Equipment Summary Make Generic Make Trade Trade Model AFUE 95 Cond AHRI ref no. Coil AHRI ref no. Efficiency 95 AFUE Efficiency SEER Heating input Sensible cooling Heating output Latent cooling Low output baseboard 5/ft Total cooling Total low baseboard 41 ft Actual air flow 293 cfm High output baseboard 7/ft Air flow factor.47 cfm/btuh Total high baseboard 29 ft Static pressure in H2O Space thermostat Load sensible heat ratio.95 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 212-Feb-24 9:11:32

4 N Level 1 3'-" Shop-Lp1 Len=371 Flow=.51 AWT=75.1 Office 1-Lp1 Len=232 Flow=.44 AWT=71.4 2'-" Shop-Lp2 Len=364 Flow=.71 Bath Manifold3 Len=29 Loops=1 SWT=66.3 Flow=. Bath Flow=. AWT=65.8 Office 1-Lp2 Len=398 Flow=.78 AWT=74.2 Office 1 Shop-Lp3 Len=358 Shop Flow=.7 Shop-Lp4 Len=339 Flow=.66 Shop-Lp5 Len=266 Flow=.52 Shop-Lp6 Len=316 Flow=.62 6'-" Manifold2 Loops=6 SWT=81.8 Flow=3.73 Job #: 712 Performed by Morgan M. Audetat for: Main St. AnyTown North America 1741 Flying Cloud Dr. Eden Prairie, MN Phone: Scale: 1 : 13 Uponor System Design Software RSU Feb-24 9:12:38...steel building and snow melt.rup

5 N Snowmelt SnowMelt1 SnowMelt1-Lp1 SnowMelt1-Lp2 Len=192Len=224 Spac=15. Spac=15. Flow=1.2 Flow=1.4 AWT=87.1 AWT=87.1 Loops=2 SWT=99.6 Flow=2.6 Job #: 712 Performed by Morgan M. Audetat for: Main St. AnyTown North America 1741 Flying Cloud Dr. Eden Prairie, MN Phone: Scale: 1 : 13 Page 2 Uponor System Design Software RSU Feb-24 9:12:38...steel building and snow melt.rup

Project Summary AH1 WebREPS, LLC

Project Summary AH1 WebREPS, LLC Job: Job Information Project Summary Date: Nov 07, 2013 AH1 By: Josh Putman Plan: Job Information 1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax: 888-971-2999 Email: sales@webrepshvac.com

More information

Project Information. Design Information. Space thermostat Load sensible heat ratio 0.87

Project Information. Design Information. Space thermostat Load sensible heat ratio 0.87 Load Short orm October 1, 26 resh Air Corporation or: Project Information Mr. and Ms. Smith 1 Easy Lane, Perfect, ST 12345 Phone: 5555555555 ax: 5555555556 Email: smiths@email.com Design Information Outside

More information

Chapter 10 Commercial Radiant Heating and Cooling Applications

Chapter 10 Commercial Radiant Heating and Cooling Applications Chapter 10 Commercial Radiant Heating and Cooling Applications This chapter summarizes aspects of radiant floor design that are specific to commercial projects. Before reading this chapter, study Chapters

More information

Residential Zoned Systems It s Different Now

Residential Zoned Systems It s Different Now The Energy Training Center Stockton and this training are funded by California utility customers and administered by Pacific Gas and Electric Company under the auspices of the California Public Utility

More information

HVAC System Design. The Sequential Process for Calculating Loads, Sizing Appliances & Designing Distribution Systems

HVAC System Design. The Sequential Process for Calculating Loads, Sizing Appliances & Designing Distribution Systems HVAC System Design The Sequential Process for Calculating Loads, Sizing Appliances & Designing Distribution Systems Mark Hutchins Conservation Services Group ACCA Method ACCA - Air Conditioning Contractors

More information

Glossary of Heating, Ventilation and Air Conditioning Terms

Glossary of Heating, Ventilation and Air Conditioning Terms Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment

More information

Dedicated Outdoor-Air Ventilation Systems 19-Sep-2001

Dedicated Outdoor-Air Ventilation Systems 19-Sep-2001 engineers newsletter Dedicated Outdoor-Air Ventilation Systems dedicated outdoor-air ventilation systems Today s Topics Background System configurations Application considerations Question-and-answer answer

More information

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000

More information

Chapter 9 Radiant Ceiling System Design

Chapter 9 Radiant Ceiling System Design Chapter 9 Radiant Ceiling System Design Designing a radiant ceiling heating system is fairly simple. Unlike radiant floor heating, floor coverings are not a concern and the surface temperature limitations

More information

HVAC System Performance Testing

HVAC System Performance Testing 2010 HVAC System Performance Testing Wes Davis Manager, Technical Services ACCA 1 Lansdowne, VA Presentation Outline Topic Time (min) ACCA Introduction ~ 5 Background & Overview Equipment Capacity ~ 30

More information

HVAC Simplified Approach Option

HVAC Simplified Approach Option HVAC Simplified Approach Option Part I Project Address: City: HVAC System Designer of Record: Date: Zip: Qualification The building is 2 stories or less in height and has a gross floor area is less than

More information

Design Criteria Data

Design Criteria Data CHARLESTON SC Latitude = 32.9 N WMO No. 7228 Longitude = 8.3 W Elevation = 49 feet Period of Record = 1967 to 1996 Average Pressure = 29.99 inches Hg Design Criteria Data Mean Coincident (Average) Values

More information

2015 Residential EnergyWise Incentives

2015 Residential EnergyWise Incentives Norris Public Power District 606 Irving Street P.O. Box 399 - Beatrice, NE 68310 (402) 223-4038 www.norrisppd.com 2015 Residential EnergyWise Incentives Programs Included: LED Lighting Incentive Attic

More information

EAM4X. Product Specifications EXPANSION VALVE COILS

EAM4X. Product Specifications EXPANSION VALVE COILS EXPANSION VALVE COILS 1 1/2 thru 5 Tons Bolt on TXV metering device factory installed on all models (equalizer tube brazed in) TXV and manifold positioned to the side for easier cleaning Innovative drain

More information

Combo Heat & Water Heating

Combo Heat & Water Heating Welcome to the Brooklyn, New York Technology & Market Assessment Forum October 6-8, 2010 New York Marriott at the Brooklyn Bridge Technology Showcase: Water Heating Combo Heat & Water Heating Rinnai Hydronic

More information

steam required = GPM x Temp Rise F (lbs/hr) 2 steam required = GPM x Temp Rise F (lbs/hr) 4 steam required = CFM x Temp Rise F (lbs/hr) 900

steam required = GPM x Temp Rise F (lbs/hr) 2 steam required = GPM x Temp Rise F (lbs/hr) 4 steam required = CFM x Temp Rise F (lbs/hr) 900 CAPACITY CALCULATIONS FOR STEAM LOADS When BTU Load is Known Capacity of = BTU steam required 0 (lbs/hr) When Square Feet Equivalent Capacity of Direct Radiation (EDR) is Known steam required = Sq ft.

More information

Below are detailed instructions for using the EMS load calculator.

Below are detailed instructions for using the EMS load calculator. Introduction The EMS load calculator is designed to make load calculating as painless as possible. For sizing the equipment, only the first three tabs (Steps 1, 2 & 3) need to be completed. This process

More information

Design Criteria Data

Design Criteria Data KOTZEBUE/RALPH WIEN AK Latitude = 66.87 N WMO No. 7133 Longitude =162.6 W Elevation = 16 feet Period of Record = 1973 to 1996 Average Pressure = 29.82 inches Hg Design Criteria Data Mean Coincident (Average)

More information

COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM

COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM COMMERCIAL HEAT GAIN - HEAT LOSS CALCULATION LOAD FORM Job Name: Address: Phone/Fax/Email: Contractor: Address: Phone/Fax/Email: Heat Gain Summary Sensible Heat (Btu/h) Latent Heat (Btu/h) Total Heat Gain

More information

Fundamentals of Hydronic Design

Fundamentals of Hydronic Design Radiant Based HVAC Systems www.healthyheating.com Heat Loss to Flow Rates www.healthyheating.com This educational material is copy written by Robert Bean, R.E.T., All Rights Reserved. If you wish to use

More information

Variable Refrigerant Flow (VRF) A Better Option Through Technology. Let s Find Out Why

Variable Refrigerant Flow (VRF) A Better Option Through Technology. Let s Find Out Why Variable Refrigerant Flow (VRF) A Better Option Through Technology Let s Find Out Why Keith Pyatt Sales Engineer LG Electronics, USA CAC Division-Central Region ND, SD and MN keith.pyatt@lge.com Office

More information

Design Criteria Data

Design Criteria Data KNOXVILLE TN Latitude = 35.82 N WMO No. 72326 Longitude = 83.98 W Elevation = 981 feet Period of Record = 1973 to 1996 Average Pressure = 29. inches Hg Design Criteria Data Mean Coincident (Average) Values

More information

HVAC Simplified Approach Option

HVAC Simplified Approach Option HVAC Simplified Approach Option Part I Project Address: City: HVAC System Designer of Record: Date: Zip: Qualification The building is 2 stories or less in height and has a gross floor area is less than

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model MGC2S (A and K) Series M120 Product Line High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 80+ AFUE Input 45,000-126,000 Btuh 2 12 YEAR ALL PARTS WARRANTY This

More information

Chapter 7 Heat Loss Considerations and Calculations

Chapter 7 Heat Loss Considerations and Calculations Chapter 7 Heat Loss Considerations and Calculations The most critical step in a properly designed radiant system is an accurate room-by-room heatloss analysis. All decisions and calculations are based,

More information

Air Conditioning Contractors of America

Air Conditioning Contractors of America Air Conditioning Contractors of America WHO IS ACCA???? Industry Manuals Residential D, J, S, H, RS, T, P A manual J load calculation is a measurement of how much heating and cooling capacity a home will

More information

The Leader in Condensing Technology. NCB-E Combi-boiler. The first high efficiency condensing combi-boiler that can do it all...

The Leader in Condensing Technology. NCB-E Combi-boiler. The first high efficiency condensing combi-boiler that can do it all... The Leader in Condensing Technology NCB-E Combi-boiler The first high efficiency condensing combi-boiler that can do it all...for larger homes Navien NCB-E combi-boiler The only compact combi-boiler strong

More information

Equipment Sizing and Duct System Design Guide

Equipment Sizing and Duct System Design Guide Bulletin 40-40 / October 2003 Equipment Sizing and Duct System Design Guide INTRODUCTION This bulletin describes the design steps necessary for a successful Unico System installation. There are only four

More information

Explanation of Blower Door Terms and Results. Information taken from TECTITE BUILDING AIRTIGHTNESS TEST by The Energy Conservatory

Explanation of Blower Door Terms and Results. Information taken from TECTITE BUILDING AIRTIGHTNESS TEST by The Energy Conservatory Explanation of Blower Door Terms and Results Information taken from TECTITE BUILDING AIRTIGHTNESS TEST by The Energy Conservatory AIRFLOW AT 50 PASCALS CFM50: This is the airflow (in Cubic Feet per Minute)

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM Page 1 UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM Each of the 38 points of requested information is discussed, and references to the supporting manual are given to substantiate the requirement.

More information

50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS

50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS 50XJ-3SB 50XJ064, 074, 084, 094, 104 WATER-COOLED VARIABLE AIR VOLUME INDOOR SELF-CONTAINED SYSTEMS PERFORMANCE DATA DIMENSION PRINTS PLENUM DIMENSION PRINT Copyright 2004 Carrier Corporation Syracuse,

More information

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects Makeup Air For Exhaust Systems In Tight Houses Tony Jellen Engineering Projects PA Housing & Land Development Conference February 23, 2012 Effects of Kitchen Ventilation on Residential Dwellings Anthony

More information

SECTION 7 AIR CONDITIONING (COOLING) UNIT 36 REFRIGERATION APPLIED TO AIR CONDITIONING

SECTION 7 AIR CONDITIONING (COOLING) UNIT 36 REFRIGERATION APPLIED TO AIR CONDITIONING SECTION 7 AIR CONDITIONING (COOLING) UNIT 36 REFRIGERATION APPLIED TO AIR CONDITIONING UNIT OBJECTIVES After studying this unit, the reader should be able to Explain three ways that heat transfers into

More information

FLORIDA SOLAR ENERGY CENTER

FLORIDA SOLAR ENERGY CENTER FLORIDA SOLAR ENERGY CENTER Creating Energy Independence Since 1975 Impact of Energy-Efficiency Parameters on Home Humidity Rob Vieira Florida Solar Energy Center A Research Institute of the University

More information

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes NCB-E Combi-boilers The first high efficiency condensing combi boilers that can do it all... for larger homes New NaviLink Wi-Fi remote control system... Available as an add-on accessory. T H E L E A D

More information

HVAC Basic Science - System Capacity

HVAC Basic Science - System Capacity HVAC Basic Science - System Capacity Btu/hour, btu/h, b/h, btuh. btu?? 1 MBH = 1000 btu/hour 1 KBH = 1000 btu/hour 1 ton of cooling= 12,000 btu/hour 1 watt = 3.414 btu/hour 1 kilowatt = 1000 watts = 3,414

More information

CAMPUS VENTILATION ENERGY SAVINGS AND IMPROVED AIR QUALITY USING LIQUID DESICCANT SYSTEMS

CAMPUS VENTILATION ENERGY SAVINGS AND IMPROVED AIR QUALITY USING LIQUID DESICCANT SYSTEMS CAMPUS VENTILATION ENERGY SAVINGS AND IMPROVED AIR QUALITY USING LIQUID DESICCANT SYSTEMS Peter Demakos, P.E., C.I.A.Q.P. February 2011 BUILDING VENTILATION Bathroom exhaust General exhaust Specialized

More information

CHAPTER III PHSYCHROMETRY AND THERMAL CONTROL

CHAPTER III PHSYCHROMETRY AND THERMAL CONTROL CHAPTER III PHSYCHROMETRY AND THERMAL CONTROL 3.1. INTRODUCTION Psychrometry studies the air properties. The psychrometric chart provides a visual picture of the changes that take place in the properties

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

YORK LINEAR ACTIVE CHILLED BEAMS ENGINEERING GUIDE

YORK LINEAR ACTIVE CHILLED BEAMS ENGINEERING GUIDE YORK LINEAR ACTIVE CHILLED BEAMS ENGINEERING GUIDE Contents YORK Active Chilled Beams 3 CB-ABL-YK Performance Data 5 CB-ABL-YK Dimensions 10 CB-ALV-YK Performance Data 12 CB-ALV-YK Dimensions 17 CB-ALE-YK

More information

Residential/Light Commercial HVAC Systems

Residential/Light Commercial HVAC Systems Residential/Light Commercial HVAC Systems Cabrillo College CEM 162 Spring 2011 1 HVAC Systems Training Terms/Definitions: System Capacities Btu/hour, btu/h, b/h, btuh, btu?? 1 MBH = 1000 btu/hour 1 KBH

More information

GAS ENGINE-DRIVEN HEATING/COOLING UNIT GE SERIES ELECTRIC HEAT/FURNACE 2 - PIPE MODELS

GAS ENGINE-DRIVEN HEATING/COOLING UNIT GE SERIES ELECTRIC HEAT/FURNACE 2 - PIPE MODELS 515.35-TG4Y (697) GAS ENGINE-DRIVEN HEATING/COOLING UNIT GE SERIES ELECTRIC HEAT/FURNACE 2 - PIPE MODELS MODEL E3GE036 (Outdoor Unit) OUTDOOR UNIT FURNACE AIR HANDLER MODEL F1GE036 &042 (Indoor Blower

More information

CPKF Split System Heat Pump

CPKF Split System Heat Pump 50 Hz CPKF Split System Heat Pump 2 to 5 Ton [7.0 kw to 17.56 kw] Nominal Capacity 24,000 to 60,000 BTU/h Standard Features Quiet operating top discharge Copper tube/aluminum fin coil Brass suction and

More information

Measuring Total System Airflow in Residential HVAC Systems

Measuring Total System Airflow in Residential HVAC Systems Measuring Total System Airflow in Residential HVAC Systems Gary Nelson Energy Conservatory Minneapolis, MN Excellence in Building 2001 Orlando, FL Friday, Oct. 26, 2001, 8:30 am Problems due to low airflow

More information

1998 Standard for Water-Source Heat Pumps. AHRI Standard (Formerly ARI Standard )

1998 Standard for Water-Source Heat Pumps. AHRI Standard (Formerly ARI Standard ) 1998 Standard for Water-Source Heat Pumps AHRI Standard 320-98 (Formerly ARI Standard 320-98) IMPORTANT SAFETY RECOMMENDATIONS It is strongly recommended that the product be designed, constructed, assembled

More information

Chapter 12 Control Strategies

Chapter 12 Control Strategies Chapter 12 Control Strategies This chapter discusses control strategies for hydronic radiant systems. Uponor offers a comprehensive line of controls from thermostats for local zone control to supply water

More information

Liebert DS. System Design Manual kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL, Dual-Cool

Liebert DS. System Design Manual kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL, Dual-Cool Precision Cooling For Business-Critical Continuity Liebert DS System Design Manual - 28-105kW (8-30 Tons), Downflow/Upflow, 60Hz Floor Mounted, Air-Cooled, Water/Glycol-Cooled, GLYCOOL, Dual-Cool TABLE

More information

Heating and Cooling Greenhouses (Greenhouse Environment) Certified Greenhouse Professional Laura Pottorff, CSU

Heating and Cooling Greenhouses (Greenhouse Environment) Certified Greenhouse Professional Laura Pottorff, CSU Heating and Cooling Greenhouses (Greenhouse Environment) Certified Greenhouse Professional Laura Pottorff, CSU Environmental factors controlling plant growth Light Temperature Water and humidity Plant

More information

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data

Tamas Hydronic Panels BTU Snow Melt Submittal Technical Data Technical Data Job or Customer : Location : Engineer : Complies with Spec Alternate Notes : Contractor : Tamas Rep : Submitted By : Date : Approved By : Date : P.O. Number : Date : Description The Tamas

More information

Residential Energy Conservation Submittal, Inspection and Compliance 2012 International Energy Conservation Code

Residential Energy Conservation Submittal, Inspection and Compliance 2012 International Energy Conservation Code Building Division Department of Community Development One DesCombes Drive 303.438.6370 VOICE www.broomfield.org Broomfield, CO 80020 303.438.6207 FAX Residential Energy Conservation Submittal, Inspection

More information

Tech Tip # 61. Why 400 CFM per Ton is used for Determining Standard Air Conditions Air Volumes

Tech Tip # 61. Why 400 CFM per Ton is used for Determining Standard Air Conditions Air Volumes Tech Tip # 61 One of a series of dealer contractor Technical advisories prepared by HARDI Wholesalers as a customer service. Why 400 CFM per Ton is used for Determining Standard Air Conditions Air Volumes

More information

Innovent LASER Packaged Fresh Air Conditioning Units

Innovent LASER Packaged Fresh Air Conditioning Units LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent

More information

Overview. Single Tube Humidifier. Single Tube (WSI) Multiple Tube Humidifier. Multiple Tube (WSI) Steam Humidifiers

Overview. Single Tube Humidifier. Single Tube (WSI) Multiple Tube Humidifier. Multiple Tube (WSI) Steam Humidifiers Overview Single Tube Humidifier Duct Supply Connection Mounting Bracket Single Tube (WSI) For direct injection of steam humidification into air stream Many tube length options to accommodate various duct

More information

Size (tons) WLNC184AA 1 1/2 WLNW364BA 3 WLNC244AA. Model WLNW424CA 3 1/2 2 WLNC244BA WLNW484CA 4 WLNC304AA

Size (tons) WLNC184AA 1 1/2 WLNW364BA 3 WLNC244AA. Model WLNW424CA 3 1/2 2 WLNC244BA WLNW484CA 4 WLNC304AA VERTICAL EVAPORATOR COILS N COIL CASED UPFLOW, DOWNFLOW R 410A SYSTEMS 1 1/2 5 Tons Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification

More information

Smart Energy Existing Homes Program

Smart Energy Existing Homes Program Smart Energy Existing Homes Program 2015-2016 Trade Ally Resource Kit TM I. Program Overview Homeowner Eligibility Measure Eligibility Trade Ally Eligibility Participation Process Quality Assurance and

More information

VG7TC TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal WARRANTY

VG7TC TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal WARRANTY TECHNICAL SPECIFICATIONS VG7TC Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas furnace may be installed free

More information

Chapter 8 Radiant Floor System Design

Chapter 8 Radiant Floor System Design Chapter 8 Radiant Floor System Design Radiant Floor Design Worksheet Project Name: Training House Main Level lthough Uponor radiant floor heating systems are quickly and accurately designed using the dvanced

More information

Top quality furnaces packed with features!

Top quality furnaces packed with features! Top quality furnaces packed with features! 60,000 to 90,000 BTUH Clean, Efficient Gas Heat Multi-Speed Blower A/C Ready Up to 5 Tons MGD-B SERIES GAS FURNACES FOR MANUFACTURED HOMES TECHNICAL INFORMATION

More information

HVAC PERFORMANCE VERIFI CERTIFICATION

HVAC PERFORMANCE VERIFI CERTIFICATION HVAC PERFORMANCE VERIFI CERTIFICATION Certification Information Scope - Tests a candidate's knowledge of a whole-system approach related to the environment being conditioned including reviewing load calculations

More information

hydronic heating Mixing Modules, Heat Exchangers and Electrical Hot Water Heaters

hydronic heating Mixing Modules, Heat Exchangers and Electrical Hot Water Heaters Floor, Wall and Radiant hydronic heating Mixing Modules, Heat Exchangers and Electrical Hot Water Heaters Compact design is ideal for retrofit installations or new construction Excellent heat distribution

More information

Heat Miser. Heat Miser. Instantaneous Steam to Water Heaters for Domestic and Process Water Heating Applications. Water Heater.

Heat Miser. Heat Miser. Instantaneous Steam to Water Heaters for Domestic and Process Water Heating Applications. Water Heater. Heat Miser Heat Miser Instantaneous to Water Heaters for Domestic and Process Water Heating Applications to Water Heater www.watsonmcdaniel.com 428 Jones Boulevard Limerick Airport Business Center Pottstown

More information

36CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 36,000 BTUH

36CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 36,000 BTUH 36CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS FEATURES High Grade 409 Stainless Steel Stainless steel heat transfer tubes Class A insulated chimney 4 models to choose from Fan forced draft Smoke by pass 20 year limited warranty Safety latch firebox

More information

CLIMATE INFLUENCES ON THE MECHANICAL SYSTEM OF A PASSIVE HOUSE

CLIMATE INFLUENCES ON THE MECHANICAL SYSTEM OF A PASSIVE HOUSE 7 th Annual North American Passive House Conference September 27-30, 2012 Denver CO CLIMATE INFLUENCES ON THE MECHANICAL SYSTEM OF A PASSIVE HOUSE Kara M McKernan PE, CEM, LEED AP, CPHC kmckernan@adginc.org

More information

BUILDING ENERGY ANALYSIS REPORT. PROJECT: Nonresidential MECH Sample 1234 Main St. Sacramento, CA 95800

BUILDING ENERGY ANALYSIS REPORT. PROJECT: Nonresidential MECH Sample 1234 Main St. Sacramento, CA 95800 BUILDING ENERGY ANALYSIS REPORT PROJECT: nresidential MECH Sample 1234 Main St. Sacramento, CA 958 Project Designer: Architectural Services 44 Yuba Dr. Suite C Sacramento, CA 95833 (916) 555-5678 Report

More information

Chapter 13 Piping Schematics

Chapter 13 Piping Schematics Chapter 3 Piping Schematics Piping Schematic Level Control Water heater Closed system Single-temperature radiant Where: All low-temperature radiant applications (< 45 F) Why: This illustration shows a

More information

Strategy Guideline: HVAC Equipment Sizing

Strategy Guideline: HVAC Equipment Sizing Strategy Guideline: HVAC Equipment Sizing Arlan Burdick IBACOS, Inc. February 2012 This report received minimal editorial review at NREL NOTICE This report was prepared as an account of work sponsored

More information

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM TOGETHERWESAVE.COM IS IT TIME TO REPLACE YOUR HVAC SYSTEM? If your heating and cooling system is 15 to 20 years old and is experiencing problems,

More information

Water Source / Geothermal Heat Pumps & Air Conditioners

Water Source / Geothermal Heat Pumps & Air Conditioners WATER SOURCE / GEOTHERMAL HEAT PUMPS AND AIR CONDITIONERS Water Source / Geothermal Heat Pumps & Air Conditioners WHISPERLINE TM VERTICAL STACK u Classic Heat Pump / Air Conditioner u Single Riser Heat

More information

Waterside Economizer. Waterside Economizer Specification Catalog and Design Guide. Applications. Sequence of Operation. Waterside Piping Schematic

Waterside Economizer. Waterside Economizer Specification Catalog and Design Guide. Applications. Sequence of Operation. Waterside Piping Schematic Waterside Economizer Applications Sequence of Operation Waterside Piping Schematic Performance Waterside Economizer Specification Catalog and Design Guide SC1650EW 04/15 Table of Contents Waterside Economizer

More information

AURORA BP Series. Optional ASME Certified BRAZED PLATE HEAT EXCHANGERS. Optional European Code

AURORA BP Series. Optional ASME Certified BRAZED PLATE HEAT EXCHANGERS. Optional European Code AURORA 1081 BP Series BRAZED PLATE HEAT EXCHANGERS Optional ASME Certified Optional European Code WWW.AURORAPUMP.COM AURORA 1081 BP Series Brazed Plate Heat Exchangers Higher Performance Increased Efficiency

More information

Central Air and Heating Systems

Central Air and Heating Systems Central Air and Heating Systems COMFORT When You NEED IT "Water is far superior to air when it comes to moving heating or cooling through buildings." -John Siegenthaler COMFORT When You NEED IT SpacePak

More information

Heat Pump Applications

Heat Pump Applications Heat Pump Applications For Rebel Commercial Rooftop Systems Rebel Advantages Rebel Is Much Better Than Competitive Heat Pumps Optional variable volume cooling Excellent energy savings Why install a unit

More information

Product Data WHC3024 through 4WHC3060 Packaged Horizontal - Over/Under Heat Pump 2-5 Ton R-410A (4WHC SHOWN) 02/12

Product Data WHC3024 through 4WHC3060 Packaged Horizontal - Over/Under Heat Pump 2-5 Ton R-410A (4WHC SHOWN) 02/12 Product Data 22-830-04 4WHC3024 through 4WHC3060 Packaged Horizontal - Over/Under Heat Pump 2-5 Ton R-40A (4WHC3024-042 SHOWN) 202 Trane Pub. No. 22-830-04 02/2 It's Hard to Stop a Trane. HORIZONTAL PACKAGED

More information

Theoretical Minimum Energy Use of a Building HVAC System

Theoretical Minimum Energy Use of a Building HVAC System Theoretical Minimum Energy Use of a Building HVAC System Oleksandr Tanskyi Graduate Assistant Research David E. Claridge Director Energy Systems Laboratory and Department of Mechanical Engineering Texas

More information

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)

More information

AND SIMPLE HVAC SYSTEMS

AND SIMPLE HVAC SYSTEMS The City of New York Mayor Michael R. Bloomberg NYC Buildings Robert D. LiMandri, Commissioner BUILDING HVAC (1) REQUIREMENTS MANDATORY REQUIREMENTS AND SIMPLE HVAC SYSTEMS CHAPTER 5 COMMERCIAL ENERGY

More information

ADVANTAGES CONVENIENCES FEATURES APPLICATIONS

ADVANTAGES CONVENIENCES FEATURES APPLICATIONS FEATURES High Grade 409 Stainless Steel Stainless steel heat transfer tubes Class A insulated chimney 4 models to choose from Fan forced draft Smoke by pass 20 year limited warranty Safety latch firebox

More information

POLARIS HIGH EFFICIENCY WATER HEATERS

POLARIS HIGH EFFICIENCY WATER HEATERS POLARIS HIGH EFFICIENCY WATER HEATERS POLARIS HIGH EFFICIENCY WATER HEATERS THE RIGHT CHOICE FOR HOT WATER Polaris water heaters are the ideal product for large home applications where multiple tasks like

More information

POLARIS HIGH EFFICIENCY WATER HEATERS

POLARIS HIGH EFFICIENCY WATER HEATERS POLARIS HIGH EFFICIENCY WATER HEATERS POLARIS HIGH EFFICIENCY WATER HEATERS Polaris High Efficiency Water Heaters embody all that s best about the American brand from reliable and quiet performance to

More information

A Glossary of HVAC Terms:

A Glossary of HVAC Terms: Since 1979 TACL A537C Doctor COOL & P rofessor HEA T The Team For All Seasons TM A Glossary of HVAC Terms: Confused by the many terms and acronyms surrounding your indoor comfort system? Don t be! This

More information

WATER-COOLED, HEAT PUMP (HP) SYSTEM

WATER-COOLED, HEAT PUMP (HP) SYSTEM WOJCIESZAK & ASSOCIATES, INC. CONSULTING ENGINEERS 833 EAST 5 TH STREET STUART, FLORIDA 34994 (772) 286-8696 TECHNICAL BULLETIN NO. DATE REVISION 201 04/25/06 3 WATER-COOLED, HEAT PUMP (HP) SYSTEM Constraints

More information

Split System Heat Pump

Split System Heat Pump Residential & Light Commercial HVAC Split System Heat Pump 1 1 2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 1 1 2 to 5 tons Refrigerant Circuit:

More information

Snow and ice melting system

Snow and ice melting system Snow and ice melting system Table of contents Uponor Snow and ice melting design principles... 4 The design... 6 Adjustable system solution for different structures... 8 Installing Uponor heating pipes...

More information

NORAIRE. Air To Water Heat Pump System ~ RADIANT HEATING WITH ELECTRO-BOILER ASSIST ~ COOLING WITH CHILLED WATER (OUTDOOR UNIT SOLD SEPARATELY)

NORAIRE. Air To Water Heat Pump System ~ RADIANT HEATING WITH ELECTRO-BOILER ASSIST ~ COOLING WITH CHILLED WATER (OUTDOOR UNIT SOLD SEPARATELY) NORAIRE Air To Water Heat Pump System ~ RADIANT HEATING WITH ELECTRO-BOILER ASSIST ~ COOLING WITH CHILLED WATER (OUTDOOR UNIT SOLD SEPARATELY) Features Air to water heat pump system with complete hydronic

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes 2014 British Columbia Building Code Changes A City of Kelowna interpretation of the 2014 Building Code 9.32 Ventilation changes The following changes reflect the most notable revisions and staff interpretations.

More information

Chapter 7: Heating and Cooling Systems

Chapter 7: Heating and Cooling Systems Chapter 7: Heating and Cooling Systems Design Conditions The Washington State Energy Code (WSEC) sets the following conditions for heating system design and equipment sizing: [302.2.1] Indoor Design Temperature:

More information

RADIANT COOLING SYSTEMS OPPORTUNITIES FOR RADIANT COOLING IN NORTH AMERICAN CONSTRUCTION ASHRAE REGION VI CRC: Minneapolis, MN

RADIANT COOLING SYSTEMS OPPORTUNITIES FOR RADIANT COOLING IN NORTH AMERICAN CONSTRUCTION ASHRAE REGION VI CRC: Minneapolis, MN RADIANT COOLING SYSTEMS OPPORTUNITIES FOR RADIANT COOLING IN NORTH AMERICAN CONSTRUCTION ASHRAE REGION VI CRC: Minneapolis, MN www.rehau.com Construction Automotive Industry LEARNING OBJECTIVES OF THIS

More information

CPC Commercial. 7½- to 12½-Ton Three-Phase. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners. up to 11.5 EER

CPC Commercial. 7½- to 12½-Ton Three-Phase. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners. up to 11.5 EER CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

13 SEER HEAT PUMPS Features n Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features n Coils constructed with copper tubing and enhanced aluminum FORM NO. P11-765 REV. 9 Supersedes Form No. P11-765 Rev. 8 13P*A SERIES *J, C, D IMPORTANT: This product is shipped with a nitrogen holding charge that must be vented prior to evacuation and charging.

More information

Lucien Lagrange Architects

Lucien Lagrange Architects Lucien Lagrange Architects Motorized Bypass Damper Temperature and Humidity Controller Reheat Control Elastomeric Foam Insulation High Efficiency, Deep Loading, Synthetic Media Filtration Easily Removable

More information

PAYNE. Model FD3A Sizes 018, 024 and 030 HEATING/COOLING FAN-COIL UNITS. Form No. PDS FD3A.18.1P. This document was created with FrameMaker 4.0.

PAYNE. Model FD3A Sizes 018, 024 and 030 HEATING/COOLING FAN-COIL UNITS. Form No. PDS FD3A.18.1P. This document was created with FrameMaker 4.0. This document was created with FrameMaker 4.0.4 PAYNE Heating & Cooling HEATING/COOLING FAN-COIL UNITS Model Sizes 018, 024 and 030 Model Heating/Cooling Fan-Coil Units are specifically designed for installation

More information

Efficient Space Humidity Control With Active Chilled Beam Systems

Efficient Space Humidity Control With Active Chilled Beam Systems This article was published in ASHRAE Journal, January 2012. Copyright 2012 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not

More information

Q5RF Series Single Packaged Heat Pump, Single Phase

Q5RF Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q5RF Series Single Packaged Heat Pump, Single Phase 15 SEER, 12 EER, 8.0 HSPF R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 55,000 Btuh Heating: 23,000 to 56,000 Btuh The Q5 Series

More information

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1 Air System Design Load Summary for Zona 9 DESIGN COOLING DESIGN HEATING COOLING DATA AT Feb 1800 HEATING DATA AT DES HTG COOLING OA DB / WB 32.4 C / 23.1 C HEATING OA DB / WB -0.6 C / -3.2 C Sensible Latent

More information

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration

More information

SM series Residential Geothermal Heat Pumps

SM series Residential Geothermal Heat Pumps SM series Residential Geothermal Heat Pumps Engineering Submittal Sheet Overview and Certifications 2013 Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS 1.0 GENERAL 1.01 DESCRIPTION SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS A. Scope This section specifies four sizes of fan coil units designed for hydronic heating and air conditioning. Fan

More information

Water Source Heat Pump Ceiling Mounted

Water Source Heat Pump Ceiling Mounted Replacement Parts List No. 700015600 New 11/09 Water Source Heat Pump Ceiling Mounted WCCH, WCCW Sizes 019, 024 Design 3 R410a To find your McQuay parts distributor, call 1-800-377-2787 or visit www.mcquay.com

More information