1 1 Exam Prep Plumber s Handbook, 2006 Questions and Answers (Plumbing Contractor) 1. Corrosive materials should enter the building sewer. a) Directly through the building drain. b) Through an indirect waste. c) Through a dilution neutralizing tank. d) Through a storm drainage system. 2. An industrial warehouse with a capacity for 675 employees should have drinking fountains (assume Florida plumbing code requirements). a) 1 b) 2 c) 3 d) 4 3. The required flow rate in GPM would be greatest for: a) 50' garden hoses b) Flush valve water closets c) Flush valve urinals d) Faucets, 1/2" supply 4. Bathtubs shall have overflows of at least in diameter. a) 1" b) 1 1/2" c) 2" d) 2 1/2" 5. Lavatory waste outlets shall measure minimum diameter. a) 1 1/4" b) 1 1/2" c) 2" d) 2 1/2" 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 1

2 6. A one-piece square prefabricated shower unit which is designed to be adequate for adults for will need a minimum floor area of square inches and a minimum span between walls of. a) 900 / 30" b) 900 / 32" c) 1,024 / 30" d) 1,024 / 32" 7. The cross-sectional area of a three-inch diameter pipe is: a) b) c) d) The minimum size of pipe in any travel trailer park drainage system shall be inches in diameter. a) 2" b) 3" c) 4" d) 6" 9. Travel trailer park sewer mains shall be vented at a maximum of feet for properly trapped and vented trailers. a) 80 feet b) 100 feet c) 150 feet d) 200 feet 10. The maximum rainfall rate in Jacksonville, Florida is per hour. a) 4.0" b) 4.3" c) 4.5" d) 4.7" 11. The two types of grease interceptor installations are: a) Inside and Outside b) Above ground and Below ground c) Food grease and Automotive grease d) Collectors and Separators 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 2

3 12. The flowing of polluted water from a plumbing vessel into a potable water supply due to a negative pressure in such pipe is: a) Back-siphonage b) Back pressure backflow c) Backflow - water d) Backwash 13. The waste outlet for a one-piece prefabricated square shower unit shall measure a minimum of in diameter. a) 1 1/4" b) 1 1/2" c) 2" d) 2 1/2" 14. There are five ways most likely to break the trap seals. Which of the following four choices is not one of these methods? a) Siphonage b) Gravity c) Wind effect d) Evaporation 15. When sizing commercial drain fields, the estimated sewage flow rate for an elementary school is gallons per day per student. a) 10 b) 12 c) 15 d) Cleanouts shall not be more than feet apart in horizontal drainage lines of 4" nominal diameter. a) 75 b) 80 c) 100 d) fixtures can connect to a 112 " water supply branch. a) Only 1 b) 1 or 2 c) 1, 2 or3 d) 4 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 3

4 18. Excluding interceptor traps, all fixture traps must have a water seal that is between and. inches deep. a) 2 and 4 b) 2 and5 c) 3 and 5 d) 2 and Horizontal installed plastic water piping shall be supported at not more than foot intervals by hanger or support. a) 2 b) 4 c) 8 d) The required water pressure at a bathtub faucet should be: a) 8 PSI b) 10 PSI c) 12PSI d) 15 PSI 21. The required flow rate at a bathtub faucet should be: a) 2.0 GPM b) 3.0 GPM c) 4.0 GPM d) 5.0 GPM 22. When installing a private sewage system, the system shall be designed to receive all sanitary sewage except for: a) Laundry waste b) Rooftop rainwater c) Kitchen waster d) Sewage ejectors 23. When using copper tubing for an underground water service supply pipe, it shall not be less than: a) Type M b) Type DWV c) Type C d) Type N 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 4

5 24. The ASTM standard applicable for galvanized steel water service pipe is: a) A268 b) D2282 c) B42 d) A To prevent damage, a water supply pipe that passes through a basement wall or other cast-in-place concrete needs a sleeve to provide inch clearance around the entire pipe. a) 1/4" b) 1/2" c) 1" d) 2" 26. In most cases you will have to locate a full-size cleanout outside the building at the junction of the building drain and the building sewer, usually within of the building. a) 2 feet b) 3 feet c) 4 feet d) 5 feet 27. A standpipe receptor for an automatic clothes washer shall not extend more than inches above the trap (assume IPC). a) 24" b) 30" c) 34" d) 42" 28. The minimum size for a standpipe used for an automatic clothes washer shall be in diameter. a) 1 1/4" b) 1 1/2" c) 2" d) 3" 29. A water service pipe must be separated from the sewer pipe by a minimum horizontal distance of inches (assume 2 trenches). a) 12" b) 24" c) 36" d) 60" 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 5

6 30. A building sewer pipe will require a minimum earth cover of: a) 6" b) 12" c) 16" d) 24" 31. Some devices such as pumps, sump ejectors and air conditioning equipment discharge into a drainage system with a continuous flow. The Uniform Plumbing Code allows fixture units for each GPM of flow. a) 1 b) 2 c) 4 d) The trap size that shall be used for an exterior storm water drain that is connected to a 6" storm sewer pipe will be: a) The size of the drain b) The size of the pipe c) 4" maximum d) Not required 33. A commercial office building has 3 restroom facilities: 1 facility has 20 fixture units; I facility has 12 fixture units; and 1 facility has 18 fixture units. The minimum septic tank size required for the commercial septic system described above shall be gallons. a) 1,500 b) 2,000 c) 2,250 d) 2, Of the following four choices, which one is an approved material for hot or cold underground water distribution tubing? a) ABS pressure pipe b) Fiberglass c) Asbestos cement d) Copper, Type "M" 35. A horizontal drain pipe 4" in diameter shall not drop less than in 91 feet (assume minimum slope and select the closest). a) " b) " c) ' d) ' 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 6

7 36. A 2" hi-lo fitting for a food waste disposer has two 1 1/2" double vertical tappings not more than inches apart. a) 2" b) 4" c) 6" d) 12" 37. No-Leaks Plumbing has subcontracted on a 2-story hotel in Orlando. The plans indicate 36 units with bathrooms of which 12 have kitchens. The bathrooms have tank-type water closets and the water service pipe is new copper. The minimum size water service pipe for this project will be. a) 1 1/4" b) 1 1/2" c) 2" d) 3" 38. An individual vent cannot be less than 1 1/4" in diameter. The minimum size of an individual vent connected to a horizontal 4" drain shall be in diameter. a) 1 1/4" b) 1 1/2" c) 2" d) 4" 39. Wiped joints shall have an exposed surface on each side of the joint no less than and as thick as the material being joined. a) 1/4" b) 1/2" c) 3/4" d) 1 3/8" 40. Food waste grinders used in commercial buildings shall waste directly into the sanitary drainage system. The waste pipe must be equal in size to the discharge opening. The waste pipe shall be a minimum of in diameter. a) 1 1/4" b) 1 1/2 " c) 2 " d) 3 " 41. A water closet installed in a private residence has a fixture unit value of according to the Uniform Plumbing Code. a) 2 b) 3 c) 4 d) 6 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 7

8 42. When there is not enough pressure in the city main to supply the flow at peak demand to all fixtures: a) A pressure pump or gravity tank shall be installed. b) The building will be vacated. c) A new water main will be installed. d) The administrative authority will be consulted. 43. A vent pipe must rise vertically to a point at least inches above the flood level rim of the fixture if serves before it can be offset horizontally and connected to any other vent. a) 6" b) 12" c) 24" d) 1 diameter 44. At a slope of 1/4" per foot, the maximum horizontal distance from fixture trap to vent will be (assume UPC and 2" drain). a) 2'- 6" b) 3'- 6" c) 5'-0" d) 6'- 0" 45. Pipe sizes for flushometer valve urinals shall be adequate to maintain a minimum flow rate pressure of: a) 15 PSI b) 15 GPM c) 25 PSI d) 25 GPM 46. A private septic tank drain field shall not be located with feet from any private water supply well. a) 100 b) 75 c) 50 d) A travel trailer site shall be provided with a service connection to each trailer. The minimum diameter ofthe service connection shall be: a) 3/8" b) 1/2" c) 5/8" d) 3/4" 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 8

9 48. A trailer park operates for the use of dependent trailers. The park covers an area of 1 square mile. There are 75 trailer sites. The number of toilets the park must have available is (assuming Uniform Plumbing Code and no individual sewer hookup). a) 2 b) 3 c) 4 d) Urinals with a flush valve shall be designed to operate and to flush with no more than gallons per minute of water per flush with a 15 PSI flow pressure. a) 25 b) 15 c) 5 d) The Plumber's Handbook states that a wet vent receives waste from: a) Bath tubs and showers only b) Water closets only c) Lavatories and water closets only d) Fixtures other than water closets 51. A one-story service station has 5,600 square feet. The station has 6 service stalls having a total of 2,600 square feet of working area. The area of the stalls is to be drained through a 4" diameter drainage pipe. The minimum size oil interceptor required shall be. a) 232 gallons with a minimum of 31 cubic feet. b) 300 gallons with a minimum of 40 cubic feet. c) Limited to a depth of 24", a width of36" and a length of 72". d) Approved by the local administrative authority 52. In order to illustrate isometric drawings properly,. a) A floor plan, plumbing plan and roof plan are required. b) A technical drafting class will be required. c) A sharp #2 pencil and a right triangle are required d) All of the above will be required 53. The maximum distance between hangers or supports is for 10 foot lengths of 4" cast iron pipe with lead and oakum joints. The pipe is place horizontally. a) 10feet b) 5 feet c) 3 feet d) 20 feet 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 9

10 54. A plain end joint connection for a typical vitrified clay pipe in a building sewer may be: a) A flexible coupling b) An increaser c) A decreaser d) A ground joint 55. The temperature relief valve on a domestic hot water heater shall release at a temperature of degrees F. a) 125 b) 150 c) 175 d) One may not install a vent terminal for a sanitary system within feet of any door, operable window, or vent opening unless it extends at least 3 feet above the top of the opening. a) 5 b) 7 c) 10 d) The Plumber's Handbook allows the use of as an alternate for lead and oakum joints for joining hub and spigot cat iron soil pipe. a) 1 part cement, 2 parts, sand, 1 part water b) burned lead c) flexible joints d) neoprene rubber compression gaskets 58.Steam tables, egg boilers and coffee urns shall discharge into an open receptaclesystem through: a) a direct waste pipe b) an indirect waste pipe c) a sump pump only d) a 4" vent 59. Commercial and self-service laundries shall prevent solids inches and larger from entering the drainage system. a) 1/8" b) 1/4" c) 3/8" d) 1/2" 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 10

11 60. The maximum number of fixture units that may be connected to a 3" horizontal fixture branch is (assume International Plumbing Code and 2 water closets in a one-story building). a) 12 b) 20 c) 30 d) The maximum number of fixture units that may be connected to a 4" building sewer is when the slope is 1/4" per foot (assume International Plumbing Code). a) 160 b) 180 c) 216 d) The sewage ejector sump discharge line connection has to be at least feet from the base of the soil stack or waste stack of a horizontal building gravity drain. a) 5' b) 10' c) 20' d) 25' 63. A vertical vent that serves two fixture branches installed at the same level is referred to as: a) Back-to-back vent b) Individual vent c) Opposed entry vent d) Common vent 64. The maximum developed length of a 2" vent is when it serves 12 fixture units on a 3" soil or waste stack (assume International Plumbing Code). a) 200 feet b) 60 feet c) 110 feet d) 50 feet 65. The minimum size non-integral trap required for a bidet is: a) 1 1/4" b) 1 1/2" c) 1 1/2" d) 3" 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 11

12 66. The grease retention capacity (in pounds) will be for an inside grease interceptor with three fixtures connected. a) 40 b) 50 c) 70 d) Size the outside grease interceptor according to the Uniform Plumbing Code and the following information: Fully equipped commercial restaurant with dishwasher 120 meals served per peak hour Restaurant is open 16 hours per day (2 peak hours) a) 1,500 gallons. b) 3,000 gallons c) 1,800 gallons d) 2250 gallons 68. The maximum horizontal projected roof area which will drain through a 4" roof leader is when the rainfall rate is 3" per hour according to the International Plumbing Code. a) 1,61 0 square feet b) 4,613 square feet c) 4,600 square feet d) 6,130 square feet 69. The size of the horizontal storm water drainage pipe will be when the rainfall rate is 3" per hour and the pipe slope is 1/4" per foot. The roof area of the building is 22,000 square feet. a) 6" b) 8" c) 10" d) 12" 70. As new sewage enters a septic tank, it forces an equal amount of treated liquid out through the tee of the septic tank and into the drain field. The liquid is referred to as. a) Treated waste b) Effluent c) Gray water waste d) Sewer gas 71. The total leaching area would be for a residential drain field. The septic tank size is 1,050 gallons and the tank and rain field are located in sandy loam. a) 420 square feet b) square feet c) 210 square feet d) 42,000 square feet 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 12

13 72. Typical showerheads shall have a maximum flow rate of at 80 PSI in accordance with ANSI standards. a) 1.6 GPM b) 2.2 GPM c) 2.5 GPM d) 3.5 GPM 73. According to the Plumber's Handbook, the recommended hot water storage tank capacity for a fourbedroom, 3 bath home will be gallons if an electric hot water heater is used. a) 40 b) 50 c) 52 d) According to the Plumber's Handbook, the solar water tank capacity for a 4- bedroom, 3 bath home will be: a) 40 gallons b) 70 gallons c) 100 gallons d) 130 gallons 75. The tables used to size gas piping have a capacity shown in cubic feet of natural gas per hour. Gas appliances have input ratings given in BTU/H. To convert BTU to cubic feet per hour: a) You must multiply the BTU rating given by 10 b) You must divide the BTU rating given by 1,000 c) You must multiply the cubic foot volume by 1,000 d) You divide by 1,000 then multiply by.06 and add 5% for safety 76. Of the following four choices, which one is not permitted to be used for interior above ground gas distribution material? a) Galvanized steel pipe b) Wrought iron pipe c) PE plastic pipe d) Soft copper tubing 77. The minimum required fixture clearance from a water closet centerline to an adjacent wall is: a) 12" b) 15" c) 18" d) 30" 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 13

14 78. A fire flow on-site well must be cased and sized for a flow of (assume only one standpipe serves the building). a) 250 GPM b) 500 GPM c) 750 GPM d) 1,000 GPM 79. According to the Plumbers Handbook, why are concrete collars or pads placed around the top of a well casing? a) as a support for the future well pump and air bladder tank b) to prevent displacement of the steel casing at the surface grade c) to prevent surface water from carrying pollutants down the well casing d) to provide a sufficient foundation for the pumphouse 80. According to the Plumbers Handbook, the suction line from the well casing to the pump must not be smaller than 1 inch in diameter and have a maximum length of or would have to be increased one pipe size. a) 10 feet b) 20 feet c) 30 feet d) 40 feet 81. According to the Plumbers Handbook, the main drain, which is used to drain a swimming pool, shall have a minimum diameter of. a) 1-1/2" b) 2" c) 2-1/2" d) 3" 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 14

15 1 Exam Prep Plumber's Handbook, 2006 Answers 1. Answer: C Solution: Chapter 6, Pg Neutralizing Tanks 2. Answer: B Solution: FP Code Page 4.2 Table #4 1 per / 400 = 1.68 or 2 3. Answer: B Solution: Page 162, Figure sizing water systems PG Answer: B Solution: Chapter 21, page Plumbing fixtures - Bathtubs and Showers 5. Answer: A Solution: Chapter 21, Page Plumbing fixtures, Lavs 6. Answer: C Solution: Chapter 21, Page Plumbing Fixtures, Shower 7. Answer: C Solution: Chapter 3, Page 50, Figure Math 8. Answer: B Solution: Page 143- Code assigns DFU / site 9. Answer: D Solution: Page 143, Figure Answer: B Solution: Page 99, Figure Answer: A Solution: Page 71, Grease Interceptors 12. Answer: A Solution: Page 340, Appendix, Definitions 13. Answer: C Solution: Page 255, Showers 14. Answer: B Solution: Page 60 - Broken trap seals 15. Answer: C Solution: Page 136, Figure 9-12, Schools 16. Answer: C Solution: Page 64, Answer: B Solution: Page 164, sizing water service pipe 18. Answer: A Solution: Page 54, Special Trap Requirements, Answer: B Solution: Page 185, Pipe Supports, Horizontal 20. Answer: A Solution: Page 162, Figure 12-3, Pressure = PSI 21. Answer: C Solution: Page 162, Figure 12-3, Flow Rate = GPM 22. Answer: B Solution: Page 14, Building Sewer, Not Storm 23. Answer: A Solution: Page 179, 181, Figure Answer: D Solution: Page 180, Figure Answer: B Solution: Page Answer: A Solution: Page 64, Answer: D Solution: Page , Receptors 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 15

16 28. Answer: C Solution: Page 91, Receptors 29. Answer: D Solution: Page 182, Separate Trenches, Answer: B Solution: Page 116, Figure Answer: B Solution: Page 17, Continuous Flow 32. Answer: D Solution: Page 98, Figure 7-16, No trap in detail 33. Answer: C Solution: Page 131, Figure 9-4, = 50 dfu 34. Answer: D Solution: Page 181, Figure Answer: D Solution: Page 17, Figure 2-14, Minimum slope = 1/8" per foot 1/8 =.125" 91' x.125" = " / 12" =.9479' 36. Answer: C Solution: Page 257, Figure 21-5, Food Disposers 37. Answer: C Solution: Page 162, Figure 12-4 Obtain the number of bathrooms and kitchens ( = 48) Tank-type at left, flush valve at right (use left) Copper vs galvanized (use copper) Under copper find 48 (39 to 56) move across to diameter = 2" 38. Answer: C Solution: Page 40, Basic Sizing Principles 39. Answer: C Solution: Page 112, Wiped Joints 40. Answer: C Solution: Page 257, Food Waste Disposers 41. Answer: B Solution: Page 15, Figure Answer: A Solution: Page 164, Sizing the Water Service 43. Answer: A Solution: Page 41, Basic Sizing Principles 44. Answer: C Solution: Page 58, Figure Answer: A Solution: Page 162, Figure 12-3, Required Pressure 46. Answer: A Solution: Page 32, Tanks Page 137, Fields 47. Answer: D Solution: Page 144, Not branch service line 48. Answer: C Solution: Page 142, Dependent Trailer Parks 49. Answer: B Solution: Page 162, Figure 12-3, GPM Flow Rate 5o. Answer: D Solution: Page 37, Definitions of Vent Types 51. Answer: D Solution: Page 81 and Answer: C Solution: Page 7, Isometric Drawings 53. Answer: A Solution: Page 119, Figure 8-22 B 54. Answer: A Solution: Page Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 16

17 55. Answer: D Solution: Page 171, Temperature Relief Valves 56. Answer: C Solution: Page 49, Vent Terminals 57. Answer: D Solution: Page 110, Joints and Connections 58. Answer: B Solution: Page Answer: D Solution: Page 78, 79, Interceptors 60. Answer: B Solution: Page 17, Figure Answer: C Solution: Page 17, Figure 2-14, Sewer, Not Branch 62. Answer: B Solution: Page 28, Sewage Ejectors 63. Answer: D Solution: Page 34, Figure Answer: C Solution: Page 40, Figure 3-24, 3" soil, 12 DFU, 2" vent 65. Answer: A Solution: Page 57, Figure Answer: C Solution: Page 72, Figure Answer: D Solution: Page 74, Figure Answer: D Solution: Page 96, Figure 7-14 International Plumbing Code 69. Answer: C Solution: Page 97, Figure 7-15, 114" slope, 3" rate 70. Answer: B Solution: Page 127, Definition of Septic Tank 71. Answer: A Solution: Page 135, Figure ,050 x 40 / 100 = Answer: C Solution: Page 148, Figure Answer: D Solution: Page 171, Figure bedroom, electric 74. Answer: D Solution: Page 232, Figure bedroom 75. Answer: B Solution: Page Answer: C Solution: Page 244, Figure Answer: B Solution: Page 259, 260, Figure Answer: B Solution: Page Answer: C Solution: index, water wells 80. Answer: D Solution: index, water wells 81. Answer: B Solution: index, swimming pools, see figure / dimension is shown 1 Exam Prep Plumber s Handbook, 2006 Questions (Plumbing Contractor) 17

PLUMBING ROUGH IN INSPECTION

PLUMBING ROUGH IN INSPECTION This Program is made Possible through the Code Officials Education & Training Fund. Revenue for the Fund comes from Assessments on Building Permits. Please turn down cell phones and put pagers on vibrate.

More information

Residential Plumbing BCN 1058

Residential Plumbing BCN 1058 Residential Plumbing BCN 1058 CHAPTER 7 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System MICHAEL KNOTEK 74 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System PLUMBING FIXTURES

More information

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass. CHAPTER 9 VENTS 901 GENERAL 901.1 Scope The provisions of this chapter shall govern the materials, design, construction, and installation of vents. 901.2 Protection of Trap Seals The protection of trap

More information

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations

More information

Top 10+ Mistakes of DWV plumbing design

Top 10+ Mistakes of DWV plumbing design Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of

More information

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information

More information

What to Expect From the Examination. How to Study the Plumbing Codes

What to Expect From the Examination. How to Study the Plumbing Codes Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.

More information

2006 Codes. Please verify the following before calling for inspection

2006 Codes. Please verify the following before calling for inspection INSPECTION CHECKLIST RESIDENTIAL PLUMBING ROUGH IN 2006 Codes This checklist is intended for use to prepare for an inspection. This is only a general list and is not intended to address all possible conditions.

More information

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination

More information

Amendments to the 2012 International Plumbing Code

Amendments to the 2012 International Plumbing Code Amendments to the 2012 International Plumbing Code North Central Texas Council of Governments region The following sections, paragraphs, and sentences of the 2012 International Plumbing Code are hereby

More information

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION 1 HOUSEKEEPING 2 CHANGES We will be covering the significant changes to the International Residential Code and the changes common to

More information

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007 ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007 The following are general requirements pertaining to plumbing in one and two family dwellings. This does not represent all the provisions regulating plumbing

More information

Dominic i Barbato Dpt. Of Building and Safety (818) 374 4361 domenico.barbato@lacity.org

Dominic i Barbato Dpt. Of Building and Safety (818) 374 4361 domenico.barbato@lacity.org Dominic i Barbato Dpt. Of Building and Safety (818) 374 4361 domenico.barbato@lacity.org b 2011 Los Angeles Plumbing Code LAPC changes from 2008 2011 Los Angeles Plumbing Code Consists of the following:

More information

CHAPTER 11 STORM DRAINAGE

CHAPTER 11 STORM DRAINAGE CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,

More information

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01

Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01 Job Ready Assessment Blueprint Plumbing Test Code: 3061 / Version: 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Professionalism Exhibit professional behavior Describe

More information

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004 Bellevue Bothell Kenmore Kirkland Issaquah Mercer Island Sammamish Snoqualmie Woodinville CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004 This checklist is intended for use to prepare

More information

PMA ONLINE TRAINING Venting for Plumbing Systems

PMA ONLINE TRAINING Venting for Plumbing Systems PMA ONLINE TRAINING Venting for Plumbing Systems One Hour Continuing Education Venting PMA training disclaimer The information provided in this document is intended for use as a guideline and is not intended

More information

Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved.

Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved. Teacher Assessment Blueprint Plumbing Test Code: 5175 / Version: 01 Copyright 2010 NOCTI. All Rights Reserved. General Assessment Information Blueprint Contents General Assessment Information Written Assessment

More information

When Should Examination Preparation Begin?

When Should Examination Preparation Begin? Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing

More information

CHAPTER 7 SANITARY DRAINAGE

CHAPTER 7 SANITARY DRAINAGE 701 GENERAL 701.1 Scope The provisions of this chapter shall govern the materials, design, construction, and installation of sanitary drainage systems. 701.6 Frost Protection No soil or waste pipe shall

More information

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY Draft CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY Draft Los Angeles Plumbing Code (LAPC) 2008 California Plumbing Code (CPC) 2007 Uniform Plumbing Code (UPC) 2006 Major Code Changes Preliminary

More information

Plumbing Code Sections For Commercial Food Facilities

Plumbing Code Sections For Commercial Food Facilities Plumbing Code Sections For Commercial Food Facilities SCOPE The following list of requirements summarizes the plumbing issues that are commonly addressed in commercial retail food facilities by health

More information

CHAPTER 11 STORM DRAINAGE

CHAPTER 11 STORM DRAINAGE CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be

More information

Plumbing Apprenticeship Program Curriculum

Plumbing Apprenticeship Program Curriculum Plumbing Apprenticeship Program Curriculum Plumbing Level One 02101-05 Introduction to the Plumbing Profession (5 Hours) Introduces the trainee to plumbing, starting with the history of plumbing from ancient

More information

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville Bellevue Bothell Burien Issaquah Kenmore Kirkland INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville 2009 Codes This

More information

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012 Plumbing Code in Commercial Kitchens NH BOA May 9, 2012 Main Topics Grease Interceptors Indirect Waste Receptors Cleaning Chemical Dispensers Thermal Expansion IPC - Chapter 10 Traps Interceptors Separators

More information

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents Chapter 1 Administration Chapter 3 General Regulations Chapter 5 Water Heaters Chapter 7 Sanitary Drainage Chapter 9 Vents Chapter 11 Storm Drainage Policy Statements Table of Contents Chapter 2 Definitions

More information

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS PlumbingCode06_ch10 5/29/06 8:16 AM Page 1 CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS We have covered most of the regulations you will need to know about drains and vents. This chapter will round out

More information

Understanding and Designing Plumbing Systems

Understanding and Designing Plumbing Systems Lesson A3 15 Understanding and Designing Plumbing Systems Unit A. Mechanical Systems and Technology Problem Area 3. Construction Systems Lesson 15. Understanding and Designing Plumbing Systems New Mexico

More information

Chicago Plumber Licensure Examination Information

Chicago Plumber Licensure Examination Information Chicago Plumber Licensure Examination Information This candidate guide should help you prepare for the Chicago plumber licensure examination. Part I contains general information about testing procedures.

More information

SANITARY DRAINAGE CHAPTER 7

SANITARY DRAINAGE CHAPTER 7 CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. 701.2 Sewer required.

More information

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application.

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application. ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH 020001 Purpose and Application. Article II provides rules governing the allowable connection to the City POTW and the construction and inspection of

More information

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division Brian Coppock, Regional Compliance Officer Office of Statewide Health Planning and Development Facilities Development Division CHAPTER 6 WATER SUPPLY AND DISTRIBUTION 601.0 Hot and Cold Water Required.

More information

To many people, a home s plumbing system is perceived as being extremely

To many people, a home s plumbing system is perceived as being extremely Chapter 1 Understanding Plumbing In This Chapter Knowing what you re getting yourself into Touring residential plumbing systems To many people, a home s plumbing system is perceived as being extremely

More information

Plumbing Code in Commercial Kitchens

Plumbing Code in Commercial Kitchens Plumbing Code in Commercial Kitchens City of Concord Code Administration 225-8580 Dan Clark Plumbing Inspector Tedd Evans, Chief Building Inspector Code References from the 2009 edition of the International

More information

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812 TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment

More information

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. Section:

More information

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 8 - INDIRECT WASTES

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 8 - INDIRECT WASTES CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 8 - INDIRECT WASTES Adopting Agency BSC SFM HCD DSA OSHPD CSA DPH AGR DWR CA 1 2 1/AC AC SS SS/CC 1 2 3 4 Adopt Entire Chapter X X X X X X X X X Adopt

More information

Georgia State Amendments to the International Plumbing Code

Georgia State Amendments to the International Plumbing Code Georgia State Amendments to the International Plumbing Code (2006 Edition) Georgia Department of Community Affairs Local Government Assistance Division 60 Executive Park South, N.E. Atlanta, Georgia 30329-2231

More information

DIVISION 22 PLUMBING. 22 30 00 PLUMBING EQUIPMENT 22 33 00 Domestic Water Heaters

DIVISION 22 PLUMBING. 22 30 00 PLUMBING EQUIPMENT 22 33 00 Domestic Water Heaters DIVISION 22 PLUMBING 22 00 00 PLUMBING 22 00 50 Design Criteria 22 01 00 General Requirements 22 05 00 Common Work Results 22 06 00 General Duty Valves 22 07 00 Insulation 22 08 00 Commissioning 22 10

More information

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 APPLICATION for ZONING and BUILDING PERMIT APPLICATION INSTRUCTIONS:

More information

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS PlumbingCode06_ch09 5/29/06 8:16 AM Page 1 CHAPTER 9 VENTS Most people don t think much about vents when they consider the plumbing in their home or office, but vents play a vital role in the scheme of

More information

Sanitary Waste & Vent TS 100 1 1 Friday 9:00am 12:00pm Peter Kraut PE

Sanitary Waste & Vent TS 100 1 1 Friday 9:00am 12:00pm Peter Kraut PE Sanitary Waste & Vent TS 100 1 1 Friday 9:00am 12:00pm Peter Kraut PE Waste & Vent Part 1 October 28, 2011 9:00 10:30 AM Peter A. Kraut, P.E. B.S. Architectural Engineering Technology Wentworth Institute

More information

SIZING OF WATER PIPING SYSTEM

SIZING OF WATER PIPING SYSTEM SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL E101.1 Scope. E101.1.1 This appendix outlines two procedures for sizing a water piping system (see Sections E103.3 and E201.1). The design procedures

More information

City of Elk River BASEMENT Office Use Only

City of Elk River BASEMENT Office Use Only City of Elk River BASEMENT Office Use Only Fire and Building Safety Division (FABS) Building Permit Application Notes Scan Permit Total Date Permit # PID # $ Site Address Suite/Unit Structure Type Single

More information

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes

More information

SANITARY DRAINAGE CHAPTER 7

SANITARY DRAINAGE CHAPTER 7 CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. 701.2 Sewer required.

More information

SANITARY DRAINAGE CHAPTER 7

SANITARY DRAINAGE CHAPTER 7 CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL 701.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of sanitary drainage systems. 701.2 Sewer required.

More information

Assessment Blueprint PHCC Educational Foundation Plumbing Year 2

Assessment Blueprint PHCC Educational Foundation Plumbing Year 2 Assessment Blueprint PHCC Educational Foundation Plumbing Year 2 Post-Test Code: 7662 Copyright 2008. All Rights Reserved. General Assessment Information PHCC Educational Foundation Plumbing Year 2 General

More information

Isometric Plumbing Drawings

Isometric Plumbing Drawings Building Inspections Isometric Plumbing Drawings All commercial building permit applications, in which the plumbing system has not been designed by a mechanical engineer, must include two sets of isometric

More information

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES Health Systems Protection Rev. 07/2006 35-05-20/06/07/18 OFFICE OF FOOD PROTECTION 417 FEDERAL ST

More information

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since 1920. Wet Venting. Incorporating Stack Venting and NPC Harmonization

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since 1920. Wet Venting. Incorporating Stack Venting and NPC Harmonization ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since 1920 Wet Venting Incorporating Stack Venting and NPC Harmonization Presented by: Rainier Bratsch-Blundel, CPSI Plumbing Professor

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

NPCA WHITE PAPER DESIGN CONSIDERATIONS AND DISCUSSION OF PRECAST CONCRETE GRAVITY GREASE INTERCEPTORS

NPCA WHITE PAPER DESIGN CONSIDERATIONS AND DISCUSSION OF PRECAST CONCRETE GRAVITY GREASE INTERCEPTORS NPCA WHITE PAPER DESIGN CONSIDERATIONS AND DISCUSSION OF PRECAST CONCRETE GRAVITY GREASE INTERCEPTORS TABLE OF CONTENTS Introduction...2 Guidance & Discussion on Specifying Grease Interceptors...2 Necessity

More information

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities Fats, Oil and Grease Best Management Practices Manual Information, Pollution Prevention, and Compliance Information For Food Service Facilities Pinellas County Utilities Water Quality Management Division

More information

Division A. Compliance, Objectives and Functional Statements

Division A. Compliance, Objectives and Functional Statements Division A Compliance, Objectives and Functional Statements British Columbia Plumbing Code 2012 Division A Part 1 Part 1 Compliance Section 1.1 General 1.1.1. Application of this Code... 5 1.1.2. Internal

More information

Oregon Plumbing Rule and Law RV 3.3.16

Oregon Plumbing Rule and Law RV 3.3.16 PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Lot Number. City. Architect Name SUBCONTRACTORS - COMPLETE AND ATTACH LIST ON PAGE 4

Lot Number. City. Architect Name SUBCONTRACTORS - COMPLETE AND ATTACH LIST ON PAGE 4 New Construction Permit Application Village of Shorewood Building Division One Towne Center Blvd Shorewood, IL 60404 (815)553-2310 Fax (815)744-6766 SUBMISSION CHECKLIST - Complete this application and

More information

YOUR HOME S PLUMBING SYSTEM By Tim Oglesby, Home Check America

YOUR HOME S PLUMBING SYSTEM By Tim Oglesby, Home Check America YOUR HOME S PLUMBING SYSTEM By Tim Oglesby, Home Check America Plumbing has changed significantly since the days when American s lived in little houses on the prairie. Unfortunately, many homeowners don

More information

CHAPTER 2: The Plumbing System

CHAPTER 2: The Plumbing System CHAPTER 2: The Plumbing System SECTION I: SIZING REQUIREMENTS Establish building dimensions Building height can be determined either by architectural drawings or # of floors times height/floor. (ex: 1

More information

APPLICATION FOR NEW CONSTRUCTION

APPLICATION FOR NEW CONSTRUCTION CITY OF ELKINS 401 DAVIS AVE ELKINS WV 26241 Date Pd: Receipt #: Session #: PHIL ISNER BLDG INSPECTOR / CODE ENFORCEMENT OFFICER 304-636-1414 Ext 1431 APP. DATE APPLICATION FOR NEW CONSTRUCTION APPLICANT

More information

Apprenticeship Curriculum Standard. Plumber. Level 2. Trade Code: 306A

Apprenticeship Curriculum Standard. Plumber. Level 2. Trade Code: 306A Apprenticeship Curriculum Standard Plumber Level 2 Trade Code: 306A Date: 2007 Please Note: Apprenticeship Training and Curriculum Standards were developed by the Ministry of Training, Colleges and Universities

More information

SECTION 221413 FACILITY STORM DRAINAGE PIPING

SECTION 221413 FACILITY STORM DRAINAGE PIPING SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y Foundation A foundation is the bottom part of a building. It s the element that anchors the building to the ground and transmits the building s gravity load directly to the earth. Water damage weakens

More information

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS

WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS WHITE PLAINS PLUMBING CODE PART 1. GENERAL REQUIREMENTS a. New Plumbing and Gas Piping Systems. This code in conjunction with the Plumbing and Fuel Gas Codes of the State of New York shall apply to plumbing

More information

AN ORDINANCE TO ADOPT A PLUMBING CODE FOR THE CITY OF MOBILE, ALABAMA BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MOBILE, ALABAMA, AS FOLLOWS:

AN ORDINANCE TO ADOPT A PLUMBING CODE FOR THE CITY OF MOBILE, ALABAMA BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MOBILE, ALABAMA, AS FOLLOWS: 45-009 2011 AN ORDINANCE TO ADOPT A PLUMBING CODE FOR THE CITY OF MOBILE, ALABAMA BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF MOBILE, ALABAMA, AS FOLLOWS: SECTION ONE: Code and appendices. That,

More information

One of the fundamental design elements that every

One of the fundamental design elements that every Preliminary Design Information Before starting the water system design, you must assemble a collection of information. This includes information from the owner, the local utility, and the architect. Things

More information

Chapter 7 Plumbing Connections

Chapter 7 Plumbing Connections Chapter 7 Plumbing Connections 7-1 General All plumbing equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions

More information

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Cost Estimation for Materials and Installation of Hot Water Piping Insulation Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated

More information

1 CHAPTER 4715 DEPARTMENT OF HEALTH PLUMBING CODE

1 CHAPTER 4715 DEPARTMENT OF HEALTH PLUMBING CODE 1 CHAPTER 4715 DEPARTMENT OF HEALTH PLUMBING CODE 4715.0100 DEFINITIONS. 4715.0200 BASIC PLUMBING PRINCIPLES. 4715.0300 GENERAL REGULATIONS OF PLUMBING CONSTRUCTION. 4715.0310 USE OF PUBLIC SEWER AND WATER

More information

CHAPTER 7 SANITARY DRAINAGE

CHAPTER 7 SANITARY DRAINAGE CHAPTER 7 SANITARY DRAINAGE 701.0 Materials. Part I - Drainage Systems. 701.1 Drainage piping shall be cast iron, galvanized steel, galvanized wrought iron, lead, copper, brass, Stainless Steel 304 or

More information

Backflow Bulletin #1

Backflow Bulletin #1 Backflow Bulletin #1 FIRE PROTECTION SYSTEMS Chemicals in the System Anti-Freeze, Foam, Corrosion Inhibitors, etc. Chemicals in the System Glycerin Glycerin or similar food-grade non-toxic additive Siamese

More information

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Village of Shorewood, Wisconsin SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER Prepared By: Thomas A. Zoulek, P.E., LEED A.P. Vice President Mid City Plumbing & Heating

More information

2014 Oregon Plumbing Specialty Code New Oregon Amendments

2014 Oregon Plumbing Specialty Code New Oregon Amendments 2014 OPSC Oregon Amendments Effective October 1, 2014 2014 Oregon Plumbing Specialty Code New Oregon Amendments This document outlines all the new Oregon Amendments adopted during the code promulgation

More information

foundation designed to keep water out of the basement.

foundation designed to keep water out of the basement. Preventing Sewer Backups To safeguard your home against flooding from sewer backups, you should understand your home's basic plumbing and the preventative techniques discussed in this brochure. Basement

More information

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank. SEPTIC SYSTEMS Who Has A Septic System? Approximately 30 percent of Connecticut s population is served by on-site subsurface sewage disposal systems (a.k.a. septic systems). This means a large percentage

More information

ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS

ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS Onsite Sewage Treatment & Disposal System Requirements ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM REQUIREMENTS 1. City of Ventura onsite sewage treatment and disposal system (Septic system) permit application

More information

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010

Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010 Sewer and Stormwater Back-ups Policy Adopted by Council October 4, 2010 A. Purpose The purpose of this policy is to explain how and why sewer or stormwater backups occur, what to do in the event a homeowner

More information

DIVISION 22 PLUMBING. 22 30 00 PLUMBING EQUIPMENT 22 33 00 Domestic Water Heaters

DIVISION 22 PLUMBING. 22 30 00 PLUMBING EQUIPMENT 22 33 00 Domestic Water Heaters DIVISION 22 PLUMBING 22 00 00 PLUMBING 22 00 50 Design Criteria 22 01 00 General Requirements 22 05 00 Common Work Results 22 06 00 General Duty Valves 22 07 00 Insulation 22 08 00 Commissioning 22 10

More information

PLUMBING PERMIT APPLICATION (PLUMBING PERMIT TO BE SECURED 24 HOURS BEFORE WORK STARTS)

PLUMBING PERMIT APPLICATION (PLUMBING PERMIT TO BE SECURED 24 HOURS BEFORE WORK STARTS) RESIDENTIAL ONLY Edgehill Shopping Center 43 S. DuPont Hwy. Dover, DE. 19901 Phone: 302-741-8600 Fax: 302-741-8631 Thurman Adams State Service Center 544 South Bedford Street Georgetown, DE 19947 Phone:

More information

CHAPTER 11 STORM DRAINAGE

CHAPTER 11 STORM DRAINAGE CHAPTER 11 STORM DRAINAGE 1101.0 General. 1101.1 Where Required. Roofs, paved areas, yards, courts, courtyards, vent shafts, light wells, or similar areas having rainwater, shall be drained into a separate

More information

SANITARY SEWER BACKUP. Causes & Prevention

SANITARY SEWER BACKUP. Causes & Prevention SANITARY SEWER BACKUP Causes & Prevention A. PURPOSE The purpose of this publication is twofold: 1. It provides homeowners with basic information on the causes of sanitary sewer backups. 2. It provides

More information

WATER & SEWER SERVICES

WATER & SEWER SERVICES WATER/SEWER ENGINEERING SECTION PHONE (703) 228-3677 WATER & SEWER SERVICES INFORMATION & APPLICATION PACKAGE REVISED MAY 2014 1 MAY 2014 Dear Customer: Thank you for taking the time to read this information

More information

JOB ANNOUNCEMENT Houston Housing Authority

JOB ANNOUNCEMENT Houston Housing Authority JOB ANNOUNCEMENT Houston Housing Authority POSITION TITLE: Master Plumber DEPARTMENT: Houston Housing Authority SALARY: Negotiable DATE POSTED: 11/05/09 CLOSING DATE: Until Filled FLSA CLASS: Non-Exempt

More information

SANITARY SEWER SPECIFICATIONS

SANITARY SEWER SPECIFICATIONS SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,

More information

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes)

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) Maintenance Office Administrative Office Billing Office 530-426-7802 530-426-7800 916-332-4872

More information

CHAPTER 7 SANITARY DRAINAGE

CHAPTER 7 SANITARY DRAINAGE CHAPTER 7 SANITARY DRAINAGE 701.0 Materials. Part I Drainage Systems. 701.1 Drainage piping shall be cast iron, galvanized steel, galvanized wrought iron, lead, copper, brass, Stainless Steel 304 or 316L,

More information

Georgia State Amendments to the International Plumbing Code

Georgia State Amendments to the International Plumbing Code Georgia State Amendments to the International Plumbing Code (2012 Edition) Georgia Department of Community Affairs Community Development Division 60 Executive Park South, N.E. Atlanta, Georgia 30329-2231

More information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715, 4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.

More information

CHAPTER 26 PLUMBING CODE

CHAPTER 26 PLUMBING CODE CHAPTER 26 PLUMBING CODE 26.01 PLUMBING CODE The Illinois Plumbing Code as promulgated by the Illinois Department of Public Health at 77 Illinois Administrative Code, Part 890, is hereby adopted as the

More information

WESLEY BRIAN HUTTON KNOXVILLE, TENNESSEE LICENSED MASTER PLUMBER. Dear: Human Resources

WESLEY BRIAN HUTTON KNOXVILLE, TENNESSEE LICENSED MASTER PLUMBER. Dear: Human Resources WESLEY BRIAN HUTTON KNOXVILLE, TENNESSEE LICENSED MASTER PLUMBER Dear: Human Resources As you ll see on my enclosed resume, I have the educational background, professional experience, and track record

More information

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5 PROTECTIVE PLUMBING - WHAT IS IT? TABLE OF CONTENTS Protective Plumbing What is it?...page 1 What is Foundation Drainage?...Page 2 What is a Sump Pumping System?...Page 4 Does Part of My Basement Floor

More information

The purpose of this chapter is to set forth provisions for planning, design and installation of waste disposal systems in and out of buildings

The purpose of this chapter is to set forth provisions for planning, design and installation of waste disposal systems in and out of buildings Chapter 6 Sanitary Drainage 6.1 PURPOSE The purpose of this chapter is to set forth provisions for planning, design and installation of waste disposal systems in and out of buildings 6.2 SCOPE 6.2.1 This

More information

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE No. 9195 REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2013. All rights reserved. No part of this publication may be reproduced

More information

PLUMBING. For HOME OWNERS

PLUMBING. For HOME OWNERS PLUMBIG For HOM OR If your property is located in the ational cenic rea, the Columbia River Gorge IRODUCIO Commission requires you to comply with all ational cenic rea regulations. hey can be contacted

More information

6. Principles of effective plumbing systems

6. Principles of effective plumbing systems 6. Principles of effective plumbing systems This chapter summarizes the aims and objectives of a good local plumbing system that is, the drinking-water supply that serves a building and the system for

More information

The Town of Lakeshore Basement Flooding Information to Residents

The Town of Lakeshore Basement Flooding Information to Residents The Town of Lakeshore Basement Flooding Information to Residents The following information is intended for residents that have homes connected to Municipal storm and sanitary sewers. However, rural residents

More information

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 10 - TRAPS AND INTERCEPTORS 1 2 1/AC AC SS SS/CC 1 2 3 4

CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 10 - TRAPS AND INTERCEPTORS 1 2 1/AC AC SS SS/CC 1 2 3 4 CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 10 - TRAPS AND INTERCEPTORS Adopting Agency BSC SFM HCD DSA OSHPD CSA DPH AGR DWR CA 1 2 1/AC AC SS SS/CC 1 2 3 4 Adopt Entire Chapter X X X Adopt

More information

Sewage Compliance Form Instructions

Sewage Compliance Form Instructions CITY OF JOHNSTOWN DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT 401 MAIN STREET ROOM 200 JOHNSTOWN, PA 15901 814-533-2017 FAX 814-539-5816 RENEE K. DALY DIRECTOR Sewage Compliance Form Instructions 1)

More information

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Craig Selover Selover Consulting craig@dotmc.us H:248 542-3010 C:248 917-1380 Floor Plan Floor Plan All Piping WaterSense,HERS,

More information