2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions
|
|
- Sybil Lee
- 7 years ago
- Views:
Transcription
1 -Color Display Digital Pressure Switch Series /75/75H NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green OFF Green Red Red Green (E75H) -color digital IP67 Metal Body Type (Die-cast aluminum) RoHS ZSE0 E0 ZSE0 E0 ZSE0 E0 A ZSM See abnormal values at a glance. 0 mm character height M Connector Lead wire with M connector (5 m) Straight and right-angled connectors With Bracket User-selectable mounting orientation Functions Anti-chattering Display calibration Zero-clear Keylock Display unit switching (Fixed SI unit in Japan) For Air ( ) For General Fluids E75 (0 ) E75H (5 ) Withstand pressure: times the rated pressure Model with initial display settings of psi is also available as standard. Port size Rc/, NPT/, G/ (O79) OUT OUT OUT Plain Gray Orange 8
2 -Color Display Digital Pressure Switch For Air Series RoHS How to Order 0 M Piping specifications 0 Rc/ N0 NPT/ F0 G/ (O 79) Nil M P Output specifications settings NPN open collector outputs (Pin no.:, ) Fixed setting: NPN open collector output (Pin no.: ) + PNP open collector output (Pin no.: ) PNP open collector output (Pin no.: ) settings PNP open collector outputs (Pin no.:, ) Unit specifications With display unit switching function Fixed SI unit Note) Pressure unit: psi (Initial value) With display unit switching function Note ) Under the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note ) Fixed unit: Option Nil None With bracket A Note) Mounting screws are not included. Option Nil None Lead wire with M connector (5 m), S straight Lead wire with M connector (5 m), L right-angled Option/Part No. When optional parts are required separately, use the following part numbers to place an order. Option Part no. Note Bracket Lead wire with M connector, straight Lead wire with M connector, right-angled ZS--A ZS--B ZS--C Bracket B Bracket assembly Bracket B and the bracket assembly make up one set. Note) Mounting screws are not included. Lead wire length: 5 m Lead wire length: 5 m 8
3 -Color Display Digital Pressure Switch For Air Series Specifications For details about the Pressure Switch Precautions, refer to pages 76 and 76. For details about the Specific Product Precautions, refer to the Operation Manual at SMC website. Model Rated pressure range Pressure display range/set pressure range Withstand pressure Pressure display resolution/set pressure resolution Applicable fluid Power supply voltage Current consumption Switch output Environment Temperature characteristics (5 C reference: within operating temperature range) Standards Wetted parts material Port size Lead wire Note ) Weight Enclosure Fluid temperature range Operating temperature range Operating humidity range Withstand voltage Insulation resistance 0 to 0. to Air, Non-corrosive gas, Non-flammable gas to VDC±0%, Ripple (p-p) 0% or less (with power supply polarity protection) 55 ma or less (at no load) Output -7: settings; NPN open collector outputs (Pin no.:, ) Note ) Output -: Fixed setting; NPN open collector output (Pin no.: ) + PNP open collector output (Pin no.: ) Output -65: PNP open collector output (Pin no.: ) Output -67: settings; PNP open collector outputs (Pin no.:, ) Max. load current 80 ma Max. applied voltage 0 V (at NPN output) Residual voltage V or less (with load current of 80 ma) Response time.5 ms (with anti-chattering function: 0 ms, 60 ms, 60 ms, 000 ms, 000 ms) Short circuit protection With short circuit protection Repeatability ±0.5%F.S. Hysteresis mode Hysteresis Variable (0 or above) Window comparator mode Display Display accuracy -digit, 7-segment indicator, -color display (Red/Green) can be interlocked with the switch output, Sampling cycle: 5 times/ s %F.S.± digit (at 5 C± C) OUT: Light up when output is turned ON. (Green) Indicator light Functions OUT: Light up when output is turned ON. (Red: for output -7, -67) Anti-chattering function, Display unit switching function, Zero-clear function, Keylock function IP67 Note ) 0 to 50 C (No freezing or condensation) Operating: 0 to 50 C, Stored: 0 to 60 C (No freezing or condensation) Operating and stored: 5 to 85%RH (No condensation) 000 VAC for minute between terminals and housing 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing ±%F.S. CE, UL/CSA (E6656) RoHS Fitting: C60 (electroless nickel plating) Sensor pressure receiving area: Silicon, O-ring: NBR 0: Rc/, N0: NPT/, F0: G/ (O 79) Note ) Oilproof cable with M -pin pre-wired connector, cores, ø, 5 m, Conductor O.D.: 0.7 mm, Insulator O.D.:. mm 90 g (excluding the lead wire with M -pin pre-wired connector) Note ) The NPN and PNP outputs function for a single set point. Note ) An FKM gasket is used for the product case seal. Refer to the Operation Manual at SMC s website for details. Note ) G/: Applicable to O 79- Note ) For details about wiring, refer to the Operation Manual that can be downloaded from SMC website ( ZSE0 E0 ZSE0 E0 ZSE0 E0 A ZSM 85
4 -Color Display Digital Pressure Switch For General Fluids Series E75/75H RoHS How to Order 0 E75 0 M 5 E75H 0 M Piping specifications 0 Rc/ N0 NPT/ F0 G/ (O 79) Made to Order Symbol X500 Specifications Analog voltage output Refer to page 8 for details. Output specifications settings 7 NPN open collector outputs (Pin no.:, ) Fixed setting: NPN open collector output (Pin no.: ) + PNP open collector output (Pin no.: ) 65 PNP open collector output (Pin no.: ) 67 settings PNP open collector outputs (Pin no.:, ) Option Nil None With bracket A Nil M P Unit specifications With display unit switching function Fixed SI unit Note) Pressure unit: psi (Initial value) With display unit switching function Note ) Under the New Measurement Law, sales of switches with the unit switching function are not allowed for use in Japan. Note ) Fixed unit: Note) Mounting screws are not included. Option Nil None Lead wire with M connector (5 m), S straight Lead wire with M connector (5 m), L right-angled Option/Part No. When optional parts are required separately, use the following part numbers to place an order. Option Part no. Note Bracket ZS--A Bracket B and the bracket assembly make up one set. Bracket B Bracket assembly Note) Mounting screws are not included. Lead wire with M connector, straight ZS--B Lead wire length: 5 m Lead wire with M connector, right-angled ZS--C Lead wire length: 5 m 86
5 -Color Display Digital Pressure Switch For General Fluids Series E75/75H Specifications For details about the Pressure Switch Precautions, refer to pages 76 and 76. For details about the Specific Product Precautions, refer to the Operation Manual at SMC website. Model E75 E75H Rated pressure range Pressure display range/set pressure range Withstand pressure 0 to 0 0. to to to 5 5 Pressure display resolution/set pressure resolution Applicable fluid Power supply voltage Current consumption 0. Fluid or gas that will not corrode stainless steel 0, 0 and 60 to VDC±0%, Ripple (p-p) 0% or less (with power supply polarity protection) 55 ma or less (at no load) Switch output Output -7: settings; NPN open collector outputs (Pin no.:, ) Note ) Output -: Fixed setting; NPN open collector output (Pin no.: ) + PNP open collector output (Pin no.: ) Output -65: PNP open collector output (Pin no.: ) Output -67: settings; PNP open collector outputs (Pin no.:, ) Max. load current Max. applied voltage Residual voltage Response time Short circuit protection Repeatability 80 ma 0 V (at NPN output) V or less (with load current of 80 ma).5 ms (with anti-chattering function: 0 ms, 60 ms, 60 ms, 000 ms, 000 ms) With short circuit protection ±0.5%F.S. Hysteresis mode Hysteresis Display Window comparator mode Variable (0 or above) -digit, 7-segment indicator, -color display (Red/Green) can be interlocked with the switch output, Sampling cycle: 5 times/ s Display accuracy %F.S.± digit (at 5 C± C) OUT: Lights up when output is turned ON. (Green) Indicator light OUT: Lights up when output is turned ON. (Red: for output -7, -67) Functions Anti-chattering function, Display unit switching function, Zero-clear function, Keylock function Environment Standards Wetted parts material Enclosure Fluid temperature range Operating temperature range Operating humidity range Withstand voltage Insulation resistance Temperature characteristics (5 C reference: within operating temperature range) Pressure sensor Fitting IP67 Note ) 5 to 80 C (No freezing or condensation) Operating: 5 to 50 C, Stored: 0 to 60 C (No freezing or condensation) Operating and stored: 5 to 85%RH (No condensation) 50 VAC for minute between terminals and housing 50 MΩ or more (50 VDC measured via megohmmeter) between terminals and housing Stainless steel 0 ±%F.S. CE, UL/CSA (E6656) RoHS Stainless steel 60 Stainless steel 0 (port size Rc/) Stainless steel 0 (port size NPT/, G/) ZSE0 E0 ZSE0 E0 ZSE0 E0 A ZSM Port size Lead wire Note ) Weight 0: Rc/, N0: NPT/, F0: G/ (O 79) Note ) Oilproof cable with M -pin pre-wired connector, cores, ø, 5 m, Conductor O.D.: 0.7 mm, Insulator O.D.:. mm 5 g (Lead wire with M -pin pre-wired connector) Note ) The NPN and PNP outputs function for a single set point. Note ) An FKM gasket is used for the product case seal. Refer to the Operation Manual at SMC s website for details. Note ) G/: Applicable to O 79- Note ) For details about wiring, refer to the Operation Manual that can be downloaded from SMC website ( Refer to page 89 for the pressure display range. 5 g 5 g (port size Rc/) 0 g (port size NPT/, G/) 87
6 Series /75/75H Set Pressure Range and Rated Pressure Range Set the pressure to within the rated pressure range. The set pressure range is the range of pressure that is possible in setting. The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.) on the switch. Although it is possible to set a value outside the rated pressure range, the specifications will not be guaranteed even if the value stays within the set pressure range. Switch Pressure range 00 kpa For (For Air) 00 kpa ( 0. ) 0 For 0 (For General Fluids) E For 5 (For General Fluids) E75H The E75(H) switch shows zero (0) when the pressure being applied goes below the lower limit of the set pressure range, when the zero-cut off display function is selected. Rated pressure range of switch Set pressure range of switch 88
7 -Color Display Digital Pressure Switch Series /75/75H Functions Display calibration function A Fine adjustment of the indicated value of the pressure sensor can be made within the range of ±5% of the read value. (The scattering of the indicated value can be eliminated.) ±5%R.D. Indicated value of pressure + 0 Applied pressure Indicated value at the time of shipment Adjustable range of display calibration function Note) When the display calibration function is used, the set pressure value may change ± digit. B Peak/Bottom hold function This function constantly detects and updates the maximum and minimum pressure values and allows the unit to hold the display value. C Keylock function Prevents operation errors such as accidentally changing setting values. D Zero-clear function The measured pressure reading can be adjusted to zero. More specifically, the factory-set reading can be corrected to within ±7%F.S. E Display unit switching function Display units can be switched with this function. Unit/Reading resolution kgf/cm bar psi E75/75H 0. (X0) F Anti-chattering function A large bore cylinder or ejector consumes a large amount of air in operation and may experience a temporary drop in the primary pressure. This function prevents detection of such temporary drops in primary pressure as abnormal pressure. Response time selections: 0 ms, 60 ms, 60 ms, 000 ms, 000 ms G Error function Take the following corrective actions when error occurs. Error description Overcurrent error Residual pressure error Applied pressure error OUT Note ) OUT System error LCD display Description Action Eliminate the cause of the over current Load current of switch by turning off the output exceeds 80 ma. power supply, and then turn on it again. During zero-clear operation, pressure over ±7% F.S. is applied. After second, the mode will reset to measurement mode. ±% F.S. of the zero-clear range varies between individual products. Supply pressure exceeds the maximum set pressure. Supply pressure is below the minimum set pressure. Internal data error Internal data error Internal data error Internal data error Perform zero-clear operation again after restoring the applied pressure to an atmospheric pressure condition. Reset applied pressure to a level within the set pressure range. Turn the power off and turn it on again. If the failure cannot be solved after the above instructions are performed, please contact SMC for investigation. Note ) Output -7 and -67 only. ZSE0 E0 ZSE0 E0 ZSE0 E0 A ZSM H Zero-cut off display function With the E75 series, users can enable or disable a function (zero-cut off display function) that displays pressure values of 0. or less as zero (0. or less in the E75H series). Example pressure displays ( shading indicates changed displays) E75- (for 0 ) Zero-cut off display function ON : 0 Displayed as Zero-cut off display function OFF : E75H- (for 5 ) Zero-cut off display function ON : 0 Displayed as Zero-cut off display function OFF : Pressure Display Range Series E75 E75H Zero-cut off display function ON 0, 0. to 0.0 0, 0.5 to 5.0 Zero-cut off display function OFF 0 to to 5.0 The set pressure range does not change when the zero-cut off display function is disabled. 89
8 Series /75/75H Dimensions /75/75H 9 9 OUT () (8.7) 5.7 Piping port 0: Rc/ N0: NPT/ F0: G/ (O 79) Note) If it is predicted that the pressure, such as the water hammer or surge pressure fluctuates rapidly, refer to the Handling Precautions stated in the Operation Manual at SMC website ( Note) The connector faces down (toward the piping). Do not attempt to rotate the connector, as it is not rotatable. Color Bracket mount 9.5 Connector pin number Output - (Color: Gray) 90 OUT DC (+) OUT (PNP) DC ( ) OUT (NPN) 5. x 6.5 Output -65 (Color: ) () (8.7).5 5 Piping port 0: Rc/ N0: NPT/ F0: G/ (O 79) DC (+) NC DC ( ) OUT (PNP) Output -7 and -67 (Color: Gray) DC (+) OUT (NPN or PNP) DC ( ) OUT (NPN or PNP) Lead wire with connector ZS--B ø5 Lead wire with connector ZS--C ø5
9 Series E75(H) Made to Order Specifications Please contact SMC for detailed dimensions, specifications and lead times. Made to Order Analog Voltage Output Specifications This product is compatible with NPN open collector output + Analog voltage output. How to Order E75(H) Piping Output Note) Option Note) The output is applicable to only. X500 Symbol -X500 Refer to How to Order on page 86 for the standard specifications. ZSE0 E0 ZSE0 E0 ZSE0 E0 Specifications Analog voltage output Output voltage: to 5 V ±.5% F.S. (In rated pressure range) Output impedance: Approx. kω Response time: 00 ms or less A Connector pin number DC (+) Analogue output DC ( ) OUT (NPN) ZSM Models other than above are the same specifications as standard. 8
3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing
More informationDigital Flow Switch for Water 3 -color/2-screen display
3-color display New Digital Flow Switch for Water 3 -color/-screen display RoHS Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated value Peak/ottom
More informationLCD Readout Digital Pressure Switch
LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationISE4. Series ZSE4. Digital Pressure Switch. LCD Readout. (For vacuum) (For positive pressure) For General Pneumatics
Choice of display units Display units can be easily selected and changed, making these switches globaly acceptable. LCD Readout Digital Pressure Switch Series (For vacuum) (For positive pressure) Vacuum
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More informationE8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationSensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationPart number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2
R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems
More informationTubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc
Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular
More informationPRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationPrecision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.
Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationWaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationRelative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
More information% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
More information2 Window comparator mode. Hysteresis Hysteresis
SERIES High-performance Digital Pressure Sensor Digital Automatic sensitivity setting With analog output Complete functionality! Selection from a wide lineup DP3 * UL 61010C-1 compatible, Passed the UL
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationConductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More informationPMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features
Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a
More informationwww.suco.de Electronic Pressure Monitoring New Products
Electronic Pressure Monitoring New Products RoHS compliant Electronic Pressure Switches SoS-Technology with one or two switching functions Electronic Pressure Switches CE marking SUCO Electronic pressure
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationE3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
More informationPhotoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems
WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More informationSeries 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
More informationDimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More informationAir Catch Sensor. Series ISA. For Workpiece Placement Confirmation
Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED
More informationLiquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationTechnical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
More informationBOS 73K... BOS 74K...
BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,
More informationPM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small
EQ-00 VF NX MS-AJ RT-0 PX- CY PHOTOELECTRIC SENSORS Mounting Stand SERIES U-shaped Micro Photoelectric PNP output type available Extremely small Ultra-small type -4(-R) contributes to the miniaturization
More informationSmall U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More informationElectronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
More informationDigital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
More informationU-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
More informationTypical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
More informationW150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationOnline data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationMagnetic proximity switches
Magnetic proximity switches Magnetic proximity switches Overview Page 38 Functional principle and installation Page 39 Cylindrical designs Page 41 Rectangular designs Page 42 37 Kurzübersicht Magnetoresistive
More informationELECTROMAGNETIC FLOWMETER COMPACT
R ELECTROMAGNETIC FLOWMETER COMPACT For conductivit Liquids MIK frequency-, switching-, analog otput digital plug on display Range from liquids, acids and caustic solutions:0.01-0.5...35-7000l/min Accuracy:
More informationNo. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1
No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------
More informationStandard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.
Motorized Actuators Motor Cables EZS /EZS for Clean Room Use This cable is a dedicated cable for connecting the linear slide of the EZS Series and EZS Series for Clean Room Use with the controller. Use
More informationInrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.
Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the
More information3 Port Solenoid Valve
ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.
More informationREGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)
More informationCompact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
More informationT0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
More informationElectronic Pressure Switches
Electronic Pressure Switches Electronic Pressure Switches c Pressure - Electronic Pressure Switches - Mechanical Pressure Switches - Pressure Transducer c Valves & Regulators c Temperature c Level c Flow
More informationDCS Input/Output Relay Card Series
Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test
More informationThru-Beam 80 to 320 mm 0.05 to 0.08 mm
Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of
More informationMTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationVehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
More informationLM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs
857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationVSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
More informationHFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
More informationInstruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
More informationResolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360
Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_ Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120
More informationProximity Sensor with All-stainless Housing
NEW Proximity Sensor with All-stainless Housing Highly Durable Proximity Sensor for Tough Environments One-piece completely stainless-steel housing with a face thickness of.8 mm! The face thickness is
More information12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
More informationSeries LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973
Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationPC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationModels SFP33 & SFP32 Pressure Transmitters
SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement
More informationThe Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
More informationMonitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space
CC-Link Communication Unit * FASTUS is a product brand of Optex FA. Monitor and control the sensors through network supported Remote controlling of fiber sensors Reduces wires and saves space OPTEX FA
More informationE2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test
Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationHow To Power A Schen
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More information