Active field distributors AFD4, AFD4. (FM), AFD8 and AFS SIMATIC. Bus links Active field distributors AFD4, AFD4 (FM), AFD8 and AFS.

Size: px
Start display at page:

Download "Active field distributors AFD4, AFD4. (FM), AFD8 and AFS SIMATIC. Bus links Active field distributors AFD4, AFD4 (FM), AFD8 and AFS."

Transcription

1 Active field distributors AFD4, AFD4 (FM), AFD8 and AFS SIMATIC Introduction 1 Installing and connecting 2 Technical specifications 3 Bus links Active field distributors AFD4, AFD4 (FM), AFD8 and AFS Product Information 02/2015 A5E AC

2 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach NÜRNBERG GERMANY A5E AC P 02/2015 Subject to change Copyright Siemens AG All rights reserved

3 Table of contents 1 Introduction Security information Active field distributor AFD4, AFD4 (FM) and AFD Active field splitter (AFS) Configuration with active field distributors Installing and connecting Screwing AFD4 / AFD4 (FM) / AFD8 and AFS to the substrate Grounding AFD4 / AFD4 (FM) / AFD8 and AFS Safety instructions for connection Connecting the field bus to the active field distributors AFD4 / AFD4 (FM) / AFD Connecting the field bus to the active field distributor AFS Maintaining and cleaning AFD4 / AFD4 (FM) / AFD8 and AFS Replacing AFD4 / AFD4 (FM) / AFD8 and AFS LED displays of the active field distributor AFD4 / AFD4 (FM) / AFD LED displays of the active field splitter (AFS) Technical specifications Standards and approvals for active field distributors AFD4 / AFD8 and AFS Standards and approval of active field distributor AFD4 (FM) Technical specifications of active field distributors AFD4 (6ES7157-0AG81-0XA0) Technical specifications for active field distributor AFD4 (FM) (6ES7655-5DX40-1AA1) Technical specifications of active field distributors AFD8 (6ES7157-0AG82-0XA0) Technical specification of active field distributors AFS (6ES7157-0AG80-0XA0) Abbreviations Index Tables Table 2-1 Terminal assignment on the active field distributor AFD4 / AFD4 (FM) / AFD Table 2-2 Terminal assignment on the active field distributor AFS Table 2-3 Permitted activities in hazardous areas Table 2-4 Status and error messages Table 2-5 Status and error messages Product Information, 02/2015, A5E AC 3

4 Table of contents Table 3-1 Industrial use Figures Figure 1-1 Example: Configuration with ring redundancy with AFD4 field distributors Figure 2-1 Example: Direct grounding of AFD4 / AFD4 (FM) Figure 2-2 Schematic representation of the interior (AFD4) Figure 2-3 Schematic representation of the interior (AFD4 (FM)) Figure 2-4 Rules for connecting the main lines Figure 2-5 Connections of AFD Figure 2-6 Connections of AFD4 (FM) Figure 2-7 Connections of AFD Figure 2-8 Terminal block AFD4 / AFD4 (FM) / AFD Figure 2-9 Preparing the bus cable Figure 2-10 AFS connections Figure 2-11 AFS terminal block Figure 2-12 Preparing the bus cable Figure 2-13 LED display AFD4 / AFD4 (FM) / AFD Figure 2-14 LED display AFS Product Information, 02/2015, A5E AC

5 Introduction 1 This product information contains important information on the active field distributors AFD4, AFD4 (FM), AFD8 and AFS. It should take priority over information provided in manuals and catalogs if conflicts occur. In addition to this product information, you need the associated manual "Bus links. DP/PA coupler, active field distributors, DP/PA Link and Y Link". It is available for download from the Internet ( Scope In this product information, we describe the specifics of the active field distributors, which can can be operated on the PA and FF field buses: AFD4, order number 6ES7157-0AG81-0XA0 AFD4 (FM), order number 6ES7655-5DX40-1AA1 AFD8, order number 6ES7157-0AG82-0XA0 AFS, order number 6ES7157-0AG80-0XA0 Note The devices listed above are functionally compatible with the previous models AFD with order number 6ES7157-0AF81-0XA0 or AFS with order number 6ES7157-0AF82-0XA0. Keep in mind the larger dimensions when replacing the devices. Setting the dimensions of plants When setting the dimensions of plants with active field distributors, use the "SIMATIC Fieldbus Calculator". It is available for download from the Internet ( 1.1 Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should Product Information, 02/2015, A5E AC 5

6 Introduction 1.2 Active field distributor AFD4, AFD4 (FM) and AFD8 also be considered. You can find more information about industrial security on the Internet ( To stay informed about product updates as they occur, sign up for a product-specific newsletter. You can find more information on the Internet ( 1.2 Active field distributor AFD4, AFD4 (FM) and AFD8 Active field distributor AFD4 / AFD4 (FM) / AFD8 Field devices such as measuring instruments, sensors and actuators can be connected to the active field distributors AFD4 / AFD4 (FM) / AFD8. In conjunction with 2 FDC 157 couplers, the field distributors AFD4 / AFD4 (FM) / AFD8 enable operation of a ring redundancy. You can use the following field distributors in a segment: Up to 8 field distributors when using AFD4 / AFD4 (FM) / AFD8 only Up to 5 field distributors with mixed use of at least one AFDiS and other AFD4 / AFD4 (FM) / AFD8 field distributors The total number of field devices in a segment is 31 devices and it is limited by a maximum of 60 ma per spur line. Functions Connection of field devices for a field bus in line or ring topology Automatic bus termination Automatic isolation of faulty segments Automatic connection of isolated segments after fault rectification Extending a segment during operation Short-circuit-proof spur lines Properties AFD4: 2 M16 cable glands for the main line AFD8: 2 M16 cable glands for the main line AFD4 (FM): 2 M20 blanking caps for the main line AFD4: 4 M16 cable glands for up to 4 field devices AFD8: 8 M16 cable glands for up to 8 field devices AFD4 (FM): 4 M16 blanking caps for up to 4 field devices Connection using screw-type terminals Reverse polarity protection connections 6 Product Information, 02/2015, A5E AC

7 Introduction 1.3 Active field splitter (AFS) Debounce logic reduces interference when connecting and disconnecting the spur lines IP30 covers for connections of the main lines Diagnostics using LED displays Power supply by means of the field bus Screw gland on substrate Grounding terminal outside Degree of protection IP66 Protective coating of printed circuit board 1.3 Active field splitter (AFS) Active field splitter (AFS) The AFS field distributor connects 2 FDC 157 couplers to a field bus segment. It enables operation of coupler redundancy on the line this way. The total number of field devices on the line is 31 devices limited by a maximum current of 1 A. Functions If a fault occurs, the main line automatically switches to the redundant FDC 157 coupler. Properties 2 M16 cable glands for the main line 4 M16 cable glands for the segment Connection using screw-type terminals Reverse polarity protection connections IP30 covers for connections of the main lines Diagnostics using LED displays Power supply by means of the field bus Power failure backup in case of failure of a main line Screw gland on substrate Grounding terminal outside Degree of protection IP66 Protective coating of printed circuit board Product Information, 02/2015, A5E AC 7

8 Introduction 1.4 Configuration with active field distributors Note Despite the IP30 covers, the requirements for Zone 2 are not met because the AFS is always connected directly to the FDC 157 coupler. See also Safety instructions for connection (Page 14) 1.4 Configuration with active field distributors Installation with ring redundancy The graphic below provides an example of the configuration with ring redundancy. The symbols for AFD4 field distributors are shown without cable glands for the main lines to maintain clarity. Figure 1-1 Example: Configuration with ring redundancy with AFD4 field distributors 8 Product Information, 02/2015, A5E AC

9 Introduction 1.4 Configuration with active field distributors Reference You can find additional configuration variants in the application planning section of the "Bus Couplings" manual. DP/PA Coupler, Active Field Distributors, DP/PA Link and Y Link" manual on the Internet ( Product Information, 02/2015, A5E AC 9

10 Introduction 1.4 Configuration with active field distributors 10 Product Information, 02/2015, A5E AC

11 Installing and connecting Screwing AFD4 / AFD4 (FM) / AFD8 and AFS to the substrate Mounting position The active field distributors AFD4 / AFD4 (FM) / AFD8 and AFS are preferably screwed in place on a flat surface with the connections at the bottom. Requirement The substrate must be level, with load-bearing capacity, and it must be vibration free. Select appropriate fixing accessories for the substrate. There should be a clearance of at least 60 mm below the modules for the connection of main lines and spur lines. You can find the drill hole spacing on the back of the enclosure base (see Technical specifications). Tools required Phillips screwdriver size 4 4 M6 fixing screws; dowels depending on the substrate Screwdriver suitable for the fixing screws used Procedure WARNING Risk of injury! There is risk of injury due to heavy weight of the field distributor. Hold the device firmly in your hand during installation. 1. Remove the 4 screws of the enclosure cover with a Phillips screwdriver. 2. Screw the lower part of the enclosure tightly to the substrate with 4 fixing screws. The torque depends on the fixing screws used. 3. Screw the enclosure cover onto the upper part of the enclosure with the 4 Phillips-recess screws. Torque 2.4 Nm. Product Information, 02/2015, A5E AC 11

12 Installing and connecting 2.2 Grounding AFD4 / AFD4 (FM) / AFD8 and AFS 2.2 Grounding AFD4 / AFD4 (FM) / AFD8 and AFS Requirement Active field distributor is mounted. Required accessories Grounding cable, at least 4.0 mm 2 Grounding the active field distributors AFD4 / AFD4 (FM) / AFD8 and AFS 1. Strip the insulation of the grounding cable to 8 mm. 2. Attach the grounding cable to the grounding terminal of the field distributor. Torque 2.0 Nm. 3. Connect the grounding cable to the equipotential bonding PA in accordance with EN DANGER Explosion hazard Sparks may occur when connecting in some circumstances. Never perform the work under explosive conditions! Note Read the safety instructions in the section Safety instructions for connection (Page 14). Equipotential bonding PA In hazardous areas, you need to implement equipotential bonding PA according to IEC Connect the equipotential bonding PA to the shielding of the bus lines. The best EMC protection is achieved with direct grounding for active field distributors. 12 Product Information, 02/2015, A5E AC

13 Installing and connecting 2.2 Grounding AFD4 / AFD4 (FM) / AFD8 and AFS Direct grounding The shielding of the bus lines is grounded directly in the hazardous area and in the safe area. This is possible if the equipotential bonding PA runs from the FDC 157 couplers (in the safe area) to the field devices (in hazardous areas), which means if a corresponding equipotential bonding conductor is installed. Note Direct grounding The braided shielding of the connection cables must be guided under the shielding clamps of the active field distributors. Example: Direct grounding of AFD4 / AFD4 (FM) Figure 2-1 Example: Direct grounding of AFD4 / AFD4 (FM) Product Information, 02/2015, A5E AC 13

14 Installing and connecting 2.3 Safety instructions for connection 2.3 Safety instructions for connection Safety information Note When laying cables and wiring, make sure that you adhere to the installation regulations in accordance with EN and any regulations specific to your country. DANGER Explosion hazard Sparks may occur when connecting in some circumstances. Therefore, use a non-magnetic screwdriver when connecting the cables. DANGER Explosion hazard A tensile load on the screws of the AFD4, AFD4 (FM), AFD8 and AFS can impair the degree of protection and is not permitted. Implement a fixed Installation for inlet of the cable! Schematic representation of the interior Figure 2-2 Schematic representation of the interior (AFD4) 14 Product Information, 02/2015, A5E AC

15 Installing and connecting 2.3 Safety instructions for connection Figure 2-3 Schematic representation of the interior (AFD4 (FM)) IP30 cover for AFD4 / AFD4 (FM) / AFD8 The connections of the main cables inside the enclosure of the AFD4 / AFD4 (FM) / AFD8 are sealed with an IP30 cover. Opening the IP30 cover switches off the voltage supply to the terminals and the feed lines. In the hazardous area Zone 2, you are permitted to open the IP30 cover during operation for visual inspection. NOTICE IP30-Cover with AFS Despite the IP30 cover, the requirements for Zone 2 are not met because the AFS is always connected directly to the FDC 157 coupler. Zone 2: Disconnecting the main line / connecting the main line to AFD4 / AFD4 (FM) / AFD8 DANGER Explosion hazard In hazardous area Zone 2, you are not permitted to disconnect the main line from an AFD4 / AFD4 (FM) / AFD8 during operation if it is connected directly to an FDC 157 coupler or an AFS. Before you start the work, disconnect the voltage supply to the FDC 157 coupler(s). In hazardous area Zone 2, you are permitted to disconnect a main line from an AFD4 / AFD4 (FM) / AFD8 during operation if it connects two AFD4 / AFD4 (FM) / AFD8. Product Information, 02/2015, A5E AC 15

16 Installing and connecting 2.3 Safety instructions for connection Zone 2: Disconnecting the main line / connecting the main line to AFS DANGER Explosion hazard In hazardous area Zone 2, you are not permitted to disconnect lines from an AFS during operation. Before you start the work, disconnect the FDC 157 coupler(s) from the voltage. 16 Product Information, 02/2015, A5E AC

17 Installing and connecting 2.3 Safety instructions for connection Rules for connecting the main lines The following examples illustrate the rules that you must observe when connecting main lines. Figure 2-4 Rules for connecting the main lines Product Information, 02/2015, A5E AC 17

18 Installing and connecting 2.3 Safety instructions for connection Rules Observe the following rules when connecting the main lines in hazardous area Zone 2: No. 1 Rule Disconnect FDC from the voltage when disconnecting the line (1) on AFD4 / AFD4 (FM) / AFD8 / AFDiS 2 Disconnect FDC 1 from the voltage when disconnecting the line (1) on AFD4 / AFD4 (FM) / AFD8 / AFDiS 3 Disconnect FDC 2 from the voltage when disconnecting the line (2) on AFD4 / AFD4 (FM) / AFD8 / AFDiS Disconnect FDC 1 and FDC 2 from the voltage when disconnecting the line (1) on AFS and AFD4 / AFD4 (FM) / AFD8 / AFDiS The following applies to all configurations: The lines (3) can be connected during operation (each highlighted in green in the figure) The spur lines S1 to S8 can always be connected during operation. Marking the main lines Note Mark the main lines on the field distributors which you are not permitted to disconnect during operation. Mark in your plant: The main lines on AFD4 / AFD4 (FM) / AFD8 that come directly from the FDC coupler The main lines on AFD4 / AFD4 (FM) / AFD8 that come directly from the AFS The main lines on AFS that come directly from the AFD4 / AFD4 (FM) / AFD8 (each highlighted in red in the figure) 18 Product Information, 02/2015, A5E AC

19 Installing and connecting 2.4 Connecting the field bus to the active field distributors AFD4 / AFD4 (FM) / AFD8 2.4 Connecting the field bus to the active field distributors AFD4 / AFD4 (FM) / AFD8 Introduction The bus cables of the AFD4 / AFD4 (FM) / AFD8 field distributors are fed into the enclosure via cable glands: The main line using T1 and T2 The spur lines to the field devices using S1 to S4 / S8 Figure 2-5 Connections of AFD4 Figure 2-6 Connections of AFD4 (FM) Figure 2-7 Connections of AFD8 Product Information, 02/2015, A5E AC 19

20 Installing and connecting 2.4 Connecting the field bus to the active field distributors AFD4 / AFD4 (FM) / AFD8 Terminal assignment Connect the wires of the bus cables using the screw-type terminals on the terminal block. Figure 2-8 Terminal block AFD4 / AFD4 (FM) / AFD8 Table 2-1 Terminal assignment on the active field distributor AFD4 / AFD4 (FM) / AFD8 Connection Terminal Assignment T1, T2 Main line + Data line - Data line S1 to S4 / S8 Spur line to the field devices + Data line - Data line Basic procedure 1. Prepare the bus cable. 2. Connect the bus cable: Open the field distributor. Connect the wires to the terminal block. Close the field distributor. Preparation of the AFD4 (FM) Note Replace blanking caps with UL- or CSA-approved lead-throughs for connection of additional field devices. The customer must use a screwed gland and a cable as specified for the application according to NEC and CEC. The installation must conform to the relevant requirements of the National Electrical Code (ANSI/NFPA-70 (NEC ). Requirement Active field distributor is mounted and grounded. 20 Product Information, 02/2015, A5E AC

21 Installing and connecting 2.4 Connecting the field bus to the active field distributors AFD4 / AFD4 (FM) / AFD8 Tools required Cross-tip screwdriver size 4 Open ring wrench 20 mm Screwdriver with 3 mm blade Small knife, diagonal cutter or FC stripping tool Required accessories Bus cable (cable type A) Sealing plugs for unused connections (10), 6ES7157-0AG80-1XA1 Stripping dimensions bus cable For secure connection of the wires in the screw-type terminals, observe the following stripping dimensions of the bus cables for the main lines and spur lines. Stripping dimensions Length of stripping Main line T1, T2 Spur lines S1-S8 Direct grounding a 90 mm 70 mm Commissioning plants with active field distributors AFD4 / AFD4 (FM) / AFD8 NOTICE Bus system failure If the event of a fault, the bus system may fail completely or partially. Before you commission a plant with ring redundancy, check the redundancy function by means of a line interruption/short circuit or by opening the IP30 covers on each AFD4 / AFD4 (FM) / AFD8 (opening the IP30 covers is also interpreted as a fault). Extending plants with active field distributors AFD4 / AFD4 (FM) / AFD8 NOTICE Fault on the main line due to connection of spur lines If a plant is already in operation, first connect the spur lines to the field devices followed by the main lines. This sequence reduces interference on the main line. Product Information, 02/2015, A5E AC 21

22 Installing and connecting 2.4 Connecting the field bus to the active field distributors AFD4 / AFD4 (FM) / AFD8 Preparing the bus cable 1. Remove the cable gland from the field distributor with the ring wrench. 2. Slide the clamping screw and the inside part of the gland with the sealing ring onto the unprepared cable. 3. Strip the cable as shown in the figure. Figure 2-9 Preparing the bus cable Connecting the bus cable 1. Open the field distributor: Remove the 4 screws of the enclosure cover with a Phillips screwdriver. 2. Guide the bus cables of the pin assignment through the cable glands. 3. For direct grounding, run the braided shielding of the bus cable under the shielding clamps. 4. Connect the wires to the terminal block. Ensure that the wires have the correct polarity. Torque 0.35 Nm. 5. Tighten the screw caps of the cable glands with a torque of 1.3 Nm. NOTICE Impairment of the degree of protection The degree of protection may be impaired if you tighten the screw caps too tight or not enough. 6. Close the field distributor: Place the enclosure cover on the enclosure base and tighten the four screws on the enclosure cover. Torque 2.4 Nm. Sealing unused cable glands NOTICE Impairment of the degree of protection Close unused cable glands with sealing plugs, order number 6ES7157-0AG80-1XA1. This is the only way to ensure degree of protection IP Product Information, 02/2015, A5E AC

23 Installing and connecting 2.5 Connecting the field bus to the active field distributor AFS 2.5 Connecting the field bus to the active field distributor AFS Introduction NOTICE Failure of field devices due to voltage dip To prevent the failure of the field devices due to a voltage dip in the event of a fault, a maximum voltage drop of 5 V between T1/T2 and Y must be assumed when using the AFS without a downstream AFD. The bus cables are guided into the enclosure by means of cable glands: The main line to the couplers using T1 and T2 The spur cables to the line using Y (all Y terminal connections are equivalent) Figure 2-10 AFS connections Center feed: Loop-through of the line If you loop-through the line on the AFS active field distributor using the cable gland Y, set the bus termination switch to OFF on both FDC 157 couplers. Terminal assignment You connect the wires of the bus cable in the active field distributor on the terminal block using screw-type terminals. Figure 2-11 AFS terminal block Product Information, 02/2015, A5E AC 23

24 Installing and connecting 2.5 Connecting the field bus to the active field distributor AFS Table 2-2 Terminal assignment on the active field distributor AFS Connection Terminal Assignment T1, T2 Main line to the FDC 157 couplers + Data line Y Line to the field devices (supply); the Y connectors are provided for max. 2 bus lines, each with a terminating resistor at the end of the line - Data line + Data line - Data line Basic procedure 1. Prepare the bus cable. 2. Connect the bus cable: Open the field distributor. Connect the wires to the terminal block. Close the field distributor. Requirement Active field distributor is mounted and grounded. Tools required Cross-tip screwdriver size 4 Open ring wrench 20 mm Screwdriver with 3 mm blade Small knife, diagonal cutter or FC stripping tool Required accessories Bus cable (cable type A) Sealing plugs for unused connections (10), 6ES7157-0AG80-1XA1 24 Product Information, 02/2015, A5E AC

25 Installing and connecting 2.5 Connecting the field bus to the active field distributor AFS Preparing the bus cable 1. Remove the cable glands from the field distributor with the ring wrench. 2. Slide the clamping screw and the inside part of the gland with the sealing ring onto the unprepared cable. 3. Strip the cable as shown in the figure. Figure 2-12 Preparing the bus cable Connecting the bus cable 1. Open the field distributor: Remove the 4 screws of the enclosure cover with a Phillips screwdriver. 2. Guide the cables of the terminal assignment through the cable glands. 3. For direct grounding, run the braided shielding of the bus cable under the shielding clamps. 4. Connect the wires to the terminal block. Ensure that the wires have the correct polarity. Torque 0.35 Nm. 5. Tighten the screw caps of the cable glands with a torque of 1.3 Nm. NOTICE Impairment of the degree of protection The degree of protection may be impaired if you tighten the screw caps too tight or not enough. 6. Close the field distributor: Place the enclosure cover on the enclosure base and tighten the four screws on the enclosure cover. Torque 2.4 Nm. Sealing unused cable glands NOTICE Impairment of the degree of protection Close unused cable glands with sealing plugs, order number 6ES7157-0AG80-1XA1. This is the only way to ensure degree of protection IP66. Product Information, 02/2015, A5E AC 25

26 Installing and connecting 2.6 Maintaining and cleaning AFD4 / AFD4 (FM) / AFD8 and AFS 2.6 Maintaining and cleaning AFD4 / AFD4 (FM) / AFD8 and AFS Permitted activities in hazardous areas The table below describes which maintenance activities are permitted on AFD4 / AFD4 (FM) / AFD8 / AFS during operation. DANGER Explosion hazard Zone 2: You may open the enclosure of the AFD4 / AFD4 (FM) / AFD8 / AFS briefly for the permitted maintenance work. Zone 22: You must not open the enclosure of the AFD4 / AFD4 (FM) / AFD8 / AFS in areas with dust. Table 2-3 Permitted activities in hazardous areas Activities Zone 2 Zone 22 Maintenance during operation (visual checks) allowed Warning: The enclosure of the AFD4 / AFD4 (FM) / AFD8 / AFS must not be opened for this activity in areas with dust. Cleaning allowed Not permitted Maintenance during operation Carry out maintenance every 6 months in the hazardous area. Maintenance of the AFD4 / AFD4 (FM) / AFD8 / AFS is basically restricted to visual inspections. The AFD4 / AFD4 (FM) / AFD8 / AFS may be in operation during this. Zone 2 Zone 22 Check that the cable entries and the grounding terminal of the enclosure are sealed and intact. Check whether there is any water or dust inside the enclosure. If there is, find out how it got there. Check that the wiring is secure (connectors, cables). Read the safety instructions in the section Safety instructions for connection (Page 14). Check that the cable entries and the grounding terminal of the enclosure are sealed and intact. Warning: It is not permitted to open the enclosure of the AFD4 / AFD4 (FM) / AFD8 / AFS. 26 Product Information, 02/2015, A5E AC

27 Installing and connecting 2.7 Replacing AFD4 / AFD4 (FM) / AFD8 and AFS Cleaning WARNING Explosion hazard in Zone 22 The layer of dust on the enclosure of the AFD4 / AFD4 (FM) / AFD8 / AFS must not exceed a thickness of 5 mm. Remove the dust layer on the enclosure regularly! Note Following cleaning, run a functional check of the AFD4 / AFD4 (FM) / AFD8 / AFS. 2.7 Replacing AFD4 / AFD4 (FM) / AFD8 and AFS DANGER Explosion hazard In mixed operation with AFD (6ES7157-0AF81-0XA0), disconnect the FDC 157 couplers from the voltage before you replace the AFD4 (6ES7157-0AG81-0XA0), AFD4 (FM) (6ES7655-5DX40-1AA1) and AFD8 (6ES7157-0AG82-0XA0) field distributors. Note Read the safety instructions in the section Safety instructions for connection (Page 14). Replacing active field distributor AFD4 / AFD4 (FM) / AFD8 Note At points where you want to connect devices, replace the blanking caps inserted in the delivery state with FM-approved screwed glands (cable gland, metric, with sealing ring: M 16x1.5: L= 8-10mm, M 20x1.5: L= 8-10mm, torque (1.8 Nm)). DANGER Explosion hazard In hazardous area Zone 2, you are not permitted to disconnect the main line from an AFD4 / AFD4 (FM) / AFD8 during operation if it is connected directly to a FDC 157 coupler or an AFS. Before you start the work, disconnect the FDC 157 coupler(s) from the voltage. Product Information, 02/2015, A5E AC 27

28 Installing and connecting 2.7 Replacing AFD4 / AFD4 (FM) / AFD8 and AFS In hazardous area Zone 2, you are permitted to disconnect a main line to an AFD4 / AFD4 (FM) / AFD8 during operation if it connects two AFD4 / AFD4 (FM) / AFD8. Perform the following steps to replace an active field distributor: 1. Remove the 4 screws of the enclosure cover with a Phillips screwdriver. 2. Loosen the black and blue screw caps. 3. Disconnect the field devices S1 to S4 / S8. 4. Open the IP30 covers T1/T2 and disconnect the main lines. 5. Detach the grounding cable from the grounding terminal of the field distributor. 6. Replace the module. 7. Attach the grounding cable to the grounding terminal with a torque of 2.0 Nm. 8. Connect the field devices to the new AFD4 / AFD4 (FM) / AFD8. 9. Connect the main cables T1/T2 and close the IP30 covers until you hear them engage. 10.Tighten the screw caps with 1.3 Nm. 11.Place the enclosure cover on the base and tighten the 4 screws with the washers on the enclosure with a torque of 2.4 Nm. Replacing active field splitter AFS DANGER Explosion hazard in Zone 2 In hazardous area Zone 2, you are not permitted to disconnect lines from an AFS during operation. Before you start the work, disconnect the voltage supply to the FDC 157 coupler(s). Perform the following steps to replace an active field splitter AFS (6ES7157-0AG80-0XA0): 1. Remove the 4 screws of the enclosure cover with a Phillips screwdriver. 2. Loosen the black and blue screw caps. 3. Disconnect the line on the AFS. 4. Open the IP30 covers T1/T2 and disconnect the main lines. 5. Detach the grounding cable from the grounding terminal of the field distributor. 6. Replace the module. 7. Attach the grounding cable to the grounding terminal with a torque of 2.0 Nm. 8. Connect the line to the new AFS. 9. Connect the main cables T1/T2 and close the IP30 covers until you hear them engage. 10.Tighten the screw caps with 1.3 Nm. 11.Place the enclosure cover on the base and tighten the 4 screws with the washers on the enclosure with a torque of 2.4 Nm. 28 Product Information, 02/2015, A5E AC

29 Installing and connecting 2.8 LED displays of the active field distributor AFD4 / AFD4 (FM) / AFD8 2.8 LED displays of the active field distributor AFD4 / AFD4 (FM) / AFD8 Status and error messages of the active field distributor AFD4 / AFD4 (FM) / AFD8 Figure 2-13 LED display AFD4 / AFD4 (FM) / AFD8 Table 2-4 Status and error messages LED T1, T2 LED S1 to S8 Meaning green Main line is connected. Remedy orange Bus termination is inactive. Automatic bus termination is active. Cause: For example, last AFD in the line Short-circuit or no-load operation on the respective segment of the main line (T1 or T2) Flashes orange Cover of the main line terminal is open. Close the cover. Off Wires of a main line are reversed. Correct the wiring. Off No field device is connected to the respective spur line. green A field device is connected to the respective spur line. Flashes slowly Short-circuit on the spur line Eliminate the cause of the error. Product Information, 02/2015, A5E AC 29

30 Installing and connecting 2.9 LED displays of the active field splitter (AFS) LED T1, T2 LED S1 to S8 Meaning Remedy Flashes rapidly Debounce function is active (5 s after changes to the spur lines, for example, before or after a short-circuit) Wait for 5 s. One of the states "off", "blue" or "slow flashing" occurs. 2.9 LED displays of the active field splitter (AFS) Status and error messages from the active field splitter (AFS) Figure 2-14 LED display AFS Table 2-5 Status and error messages LED T1, T2 LED Y Meaning green Main line is connected. Remedy Red Bus termination is inactive. Short-circuit or no-load operation on the main line to a coupler Eliminate the cause of the error. Flashes red Cover of the main line terminal is open. Close the cover. Off Wires of a main line are reversed. Correct the wiring. green LED lights up when the current of the Y line is > 10 ma. 30 Product Information, 02/2015, A5E AC

31 Technical specifications Standards and approvals for active field distributors AFD4 / AFD8 and AFS CE approval The described components meet the requirements and protective goals of the following EC directives and comply with the harmonized European Standards (EN), published for programmable logic controllers (PLC) in the official gazettes of the European Union: 2004/108/EG "Electromagnetic compatibility" (EMC Guidelines) 94/9/EG "Equipment and protective systems for use in hazardous areas" (Explosion protection directive) The EC Declarations of Conformity are available to the relevant authorities at the following address: Siemens Aktiengesellschaft Industry Sector I IA AS FA WF AMB Postfach 1963 D Amberg ATEX approval AFD4 / AFD8 II 3G Ex na ic [ic] IIC T4 Gc II 3D Ex tc [ic] IIIC T80 C Dc IP66 AFS II 3G Ex na IIC T4 Gc II 3D Ex tc IIIC T80 C Dc IP66 DEKRA 12ATEX0222X Ta = -40 C +70 C according to EN (Electrical apparatus for potentially explosive atmospheres; Type of protection "n") EN (Electrical apparatus for potentially explosive gas atmospheres Part 0: General Requirements) EN (AFD4 and AFD8 only) (Explosive atmospheres Part 11: Equipment protection by intrinsic safety "i") EN (Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure "t") Product Information, 02/2015, A5E AC 31

32 Technical specifications 3.1 Standards and approvals for active field distributors AFD4 / AFD8 and AFS WARNING Personal injury and material damage can be incurred. In hazardous areas, personal injury and material damage can be incurred if plug connections are disconnected during operation. In hazardous areas, only disconnect the plug connections of all components when they are not under current. The exceptions are described in the section Safety instructions for connection (Page 14). IECEx approval IECEx DEK X INMETRO approval UL-BR X Korea approval KC registration number: KCC-REM-S49-DPPA Please note that this device corresponds to limit value class A in terms of the emission of radio frequency interference. This device can be used in all areas, except residential areas. 이기기는업무용 (A 급 ) 전자파적합기기로서판매자또는사용자는이점을주의하시기바라며가정외의지역에서사용하는것을목적으로합니다. Tick mark for Australia and New Zealand The active field distributors AFD4, AFD8 and AFS meet the requirements of the standards IEC , IEC Industrial use SIMATIC products are designed for industrial applications. Table 3-1 Industrial use Area of application Requirements with regard to Interference emission Noise immunity Industry EN : 2007 EN : Product Information, 02/2015, A5E AC

33 Technical specifications 3.2 Standards and approval of active field distributor AFD4 (FM) 3.2 Standards and approval of active field distributor AFD4 (FM) FM approval Factory Mutual Research (FM) conforming to Approval Standard Class Number 3611, 3600, 3810 ANSI/ISA (IEC ) CSA C22.2 No. 213 CSA 22.2 No APPROVED for use in Class I, II, III Division 2, Groups A, B, C, D, E, F, G T4; Class I, Zone 2, Group IIC T4; Zone 22, AEx tc; IIIC T 80 C IP 66 Type 4X Installation notes 1. The AFD4 (FM) (MLFB = 6ES7655-5DX40-1AA1) is only suitable for installation in DIV. 2 / Zone 2 locations, and is not suitable for installation in DIV. 1 / Zone 1 or Zone 0 hazardous (classified) locations. 2. AFD4 (FM) and all other approved devices in the fieldbus system must be installed in accordance with the manufacturer s instructions. 3. Replace blank out panels (caps) by UL or CSA approved lead-throughs for connection of more field devices. Customer has to use a gland and cable "listed for the application" based on the NEC and CEC. Installations shall comply with the relevant requirements of the National Electrical Code (ANSI/NFPA-70 (NEC ), where applicable. 4. WARNING FOR APPLICATIONS IN DIV. 2 / ZONE 2 (CLASSIFIED) LOCATIONS: EXPLOSION HAZARD. EXCEPT FOR SPUR LINES (FIELD DEVICES), DO NOT CONNECT OR DISCONNECT ANY TRUNK LINE UNLESS THE AREA IS KNOWN TO BE NONHAZARDOUS. 3.3 Technical specifications of active field distributors AFD4 (6ES7157-0AG81-0XA0) Technical specifications Order number 6ES7157-0AG81-0XA0 Product version 01 Dimensions and weight Product Information, 02/2015, A5E AC 33

34 Technical specifications 3.3 Technical specifications of active field distributors AFD4 (6ES7157-0AG81-0XA0) Dimension W x H x D (mm) 220 x 120 x 83; without cable gland Mounting dimensions (mm) 204 x 82 Weight 2000 g Supply voltages Description By bus; no auxiliary power necessary Rated value Low limit of permitted range (DC) 16 V High limit of permitted range (DC) 32 V Polarity reversal protection ; in conjunction with FDC 157 Overvoltage protection No Power consumption Power consumption at no-load 24 ma Power consumption 24 ma + total current of all field devices Additional power consumption of the AFD4 at end of line Power consumption at max. current output per spur line 30 ma 264 ma Power loss Power loss, min. 384 mw Power loss, max. 3.2 W Interfaces PROFIBUS PA FOUNDATION Fieldbus H1 Connections Main cables Quantity 2 Connection terminals (internal) Screw-type terminals (2-pin) Cable gland (enclosure) M16 Cable type Type A Min. cable diameter 4 mm Max. cable diameter 9 mm Min. conductor cross-section 0.2 mm 2 Max. conductor cross-section 2.5 mm 2 Automatic bus termination Maximum permitted continuous current on main 1 A line Spur lines Number n 4 Number of connectable field devices 4 Connection terminals Screw-type terminals (2-pin) 34 Product Information, 02/2015, A5E AC

35 Technical specifications 3.3 Technical specifications of active field distributors AFD4 (6ES7157-0AG81-0XA0) Cable gland Cable type M16 Type A Min. cable diameter 4 mm Max. cable diameter 9 mm Min. conductor cross-section 0.2 mm 2 Max. conductor cross-section 2.5 mm 2 Short-circuit proof Intrinsically safe according to FISCO Max. DC current of the field devices on spur line 1 to 4 Short-circuit current (test current) Debounce logic Maximum no-load voltage on spur line Max. current output to field devices Grounding Direct grounding Interrupts, diagnostics, status information Status display Interrupts Diagnostics function Diagnostic indicator LED Data transmission Between main line and spur lines Galvanic isolation Between main line and spur lines Environmental requirements Operating temperature No 60 ma 6 ma < 30 V 240 ma Via ground rails None Min. -40 C Passive, no repeater function No Max. 70 C Storage/transport temperatures Min. -40 C Max. 85 C Relative humidity Operation, max. 95% Degree of protection IP66 Installation Zone 2 / Zone 22 Class I Zone 2 / Division 2 Product Information, 02/2015, A5E AC 35

36 Technical specifications 3.4 Technical specifications for active field distributor AFD4 (FM) (6ES7655-5DX40-1AA1) 3.4 Technical specifications for active field distributor AFD4 (FM) (6ES7655-5DX40-1AA1) Technical specifications Order No. 6ES7655-5DX40-1AA1 Product version 01 Dimensions and weight Dimension W x H x D (mm) 220 x 120 x 83; without cable gland Mounting dimensions (mm) 204 x 82 Weight 2000 g Supply voltages Description Via bus; no auxiliary power necessary Rated value Valid range, lower limit (DC) 16 V Valid range, upper limit (DC) 32 V Polarity reversal protection ; in conjunction with FDC 157 Overvoltage protection No Current consumption Current consumption at idle 24 ma Current consumption 24 ma + total current of all field devices Additional current consumption of AFD4 at end of line Current consumption at max. current output per spur line 30 ma 264 ma Power loss Power loss, min. 384 mw Power loss, max. 3.2 W Interfaces PROFIBUS PA FOUNDATION Fieldbus H1 Connections Main lines Quantity 2 Terminals (internal) Screw-type terminals (2-pin) Cable gland (enclosure) M20 Cable type Type A Min. cable diameter Max. cable diameter Corresponds to cable gland used Min. conductor cross-section 0.2 mm 2 36 Product Information, 02/2015, A5E AC

37 Technical specifications 3.4 Technical specifications for active field distributor AFD4 (FM) (6ES7655-5DX40-1AA1) Max. conductor cross-section 2.5 mm 2 Automatic bus termination Maximum permissible continuous main line current Spur cables Number n 4 Number of connectable field devices 4 Terminals Cable gland Cable type 1 A Screw-type terminals (2-pin) M16 Type A Min. cable diameter Max. cable diameter Corresponds to cable gland used Min. conductor cross-section 0.2 mm 2 Max. conductor cross-section 2.5 mm 2 Short-circuit proof Intrinsically safe according to FISCO No Max. DC current of the field devices spur line 1 to 60 ma 4 Short-circuit current (test current) 6 ma Debounce logic Max. no-load voltage on the spur line < 30 V Max. current output to field devices 240 ma Grounding Direct grounding By means of grounding bar Interrupts, diagnostics, status information Status indicator Interrupts None Diagnostic function Diagnostic display LED Data transmission Between main line and spur lines Passive, no repeater function Electrical isolation Between main line and spur lines No Environmental requirements Operating temperature min. -40 max. 70 Storage/transport temperature min. -40 max. 85 Product Information, 02/2015, A5E AC 37

38 Technical specifications 3.5 Technical specifications of active field distributors AFD8 (6ES7157-0AG82-0XA0) Relative humidity Operation, max. 95% Degree of protection IP66 Installation Class I Zone 2 / Division 2 Class II, III Division Technical specifications of active field distributors AFD8 (6ES7157-0AG82-0XA0) Technical specifications Order number 6ES7157-0AG82-0XA0 Product version 01 Dimensions and weight Dimension W x H x D (mm) 360 x 120 x 83; without cable gland Mounting dimensions (mm) 344 x 82 Weight 3000 g Supply voltages Description By bus; no auxiliary power necessary Rated value Low limit of permitted range (DC) 16 V High limit of permitted range (DC) 32 V Polarity reversal protection ; in conjunction with FDC 157 Overvoltage protection No Power consumption Power consumption at no-load 34 ma Power consumption 34 ma + total current of all field devices Additional power consumption of the AFD8 at end of line Power consumption at max. current output per spur line 30 ma 514 ma Power loss Power loss, min. 544 mw Power loss, max. 4.1 W Interfaces PROFIBUS PA FOUNDATION Fieldbus H1 38 Product Information, 02/2015, A5E AC

39 Technical specifications 3.5 Technical specifications of active field distributors AFD8 (6ES7157-0AG82-0XA0) Connections Main cables Quantity 2 Connection terminals (internal) Cable gland (enclosure) Cable type Screw-type terminals (2-pin) M16 Type A Min. cable diameter 4 mm Max. cable diameter 9 mm Min. conductor cross-section 0.2 mm 2 Max. conductor cross-section 2.5 mm 2 Automatic bus termination Maximum permitted continuous current on main line Spur lines Number n 8 Number of connectable field devices 8 Connection terminals Cable gland Cable type 1 A Screw-type terminals (2-pin) M16 Type A Min. cable diameter 4 mm Max. cable diameter 9 mm Min. conductor cross-section 0.2 mm 2 Max. conductor cross-section 2.5 mm 2 Short-circuit proof Intrinsically safe according to FISCO Max. DC current of the field devices on spur line 1 to 8 Short-circuit current (test current) Debounce logic Maximum no-load voltage on spur line Max. current output to field devices Grounding No 60 ma 6 ma < 30 V 480 ma Direct grounding Via ground rails Interrupts, diagnostics, status information Status display Interrupts Diagnostics function Diagnostic indicator LED Data transmission Between main line and spur lines None Passive, no repeater function Product Information, 02/2015, A5E AC 39

40 Technical specifications 3.6 Technical specification of active field distributors AFS (6ES7157-0AG80-0XA0) Galvanic isolation Between main line and spur lines No Environmental requirements Operating temperature Min. -40 C Max. 70 C Storage/transport temperatures Min. -40 C Max. 85 C Relative humidity Operation, max. 95% Degree of protection IP66 Installation Zone 2 / Zone 22 Class I Zone 2 / Division Technical specification of active field distributors AFS (6ES7157-0AG80-0XA0) Technical specifications Order number 6ES7157-0AG80-0XA0 Product version 01 Dimensions and weight Dimension W x H x D (mm) 220 x 120 x 83; without cable gland Mounting dimensions (mm) 204 x 82 Weight 2000 g Supply voltages Description By bus; no auxiliary power necessary Rated value Low limit of permitted range (DC) 16 V High limit of permitted range (DC) 32 V Polarity reversal protection ; in conjunction with FDC 157 Overvoltage protection No Power consumption Power consumption at no-load 54 ma Power loss Power loss, min. 864 mw 40 Product Information, 02/2015, A5E AC

41 Technical specifications 3.6 Technical specification of active field distributors AFS (6ES7157-0AG80-0XA0) Power loss, max W Interfaces PROFIBUS PA FOUNDATION Fieldbus H1 Connections Main cables Quantity 2 Connection terminals (internal) Cable gland (enclosure) Cable type Screw-type terminals (2-pin) M16 Type A Min. cable diameter 4 mm Max. cable diameter 9 mm Min. conductor cross-section 0.2 mm 2 Max. conductor cross-section 2.5 mm 2 Automatic bus termination Maximum permitted continuous current on main line Y, field bus connection Number n Number of connectable field devices 31 Connection terminals Cable gland Cable type No 1 A Max. 2, with bus termination resistor at the end of the line or on the FDC 157 Screw-type terminals (2-pin) M16 Type A Min. cable diameter 4 mm Max. cable diameter 9 mm Min. conductor cross-section 0.2 mm 2 Max. conductor cross-section 2.5 mm 2 Short-circuit proof ; in conjunction with FDC 157 Intrinsically-safe acc. to FISCO Max. total current at Y 1 A; limited by FDC 157 Debounce logic Maximum continuous output voltage Max. current output to field devices Grounding Direct grounding Interrupts, diagnostics, status information Status display Interrupts Diagnostics function Diagnostic indicator LED No No 32 V 1 A Via connection bar None Product Information, 02/2015, A5E AC 41

42 Technical specifications 3.7 Abbreviations Data transmission Between main line and spur lines Passive, no repeater function Galvanic isolation Between main line and spur lines No Environmental requirements Operating temperature Min. -40 C Max. 70 C Storage/transport temperatures Min. -40 C Max. 85 C Relative humidity Operation, max. 95% Degree of protection IP66 Installation Zone 2 / Zone 22 Class I Zone 2 / Division Abbreviations Abbreviation AFD AFS FDC FF PA PA S T Meaning Active Field Distributor Active Field Splitter Field Device Coupler FOUNDATION Fieldbus Process automation Equipotential bonding Spur; Connection for field devices (spur line) Trunk, connection of the main line between the field distributors AFD4 / AFD4 (FM) / AFD8, AFS or FDC 42 Product Information, 02/2015, A5E AC

43 Index A AFD4 Technical specifications, 33 AFD4 (FM) Technical specifications, 36 AFD4 / AFD4 (FM) Schematic representation, 14 AFD4 / AFD4 (FM) / AFD8 Connecting, 15 Disconnecting the main line, 15 Grounding, 12 AFD4 / AFD4 (FM) / AFD8 / AFS cleaning, 27 Maintaining, 26 AFD8 Technical specifications, 38 AFS Connecting, 16 Disconnecting the main line, 16 Grounding, 12 Loop-through of the line, 23 Technical specifications, 40 AFS (6ES7157-0AG80-0XA0) Replace, 28 ATEX approval, 31 B Bus cable Stripping dimensions, 21 Bus termination switch, 23 C Cable glands Unused, 22, 25 CE approval, 31 Center feed, 23 Connecting AFD4 / AFD4 (FM) / AFD8 Rules, 17 Safety information, 14 Coupler redundancy, 7 D Degree of protection IP66 Impairment, 22, 25 Dimensioning SIMATIC Fieldbus Calculator, 5 Direct grounding, 13 Drill hole spacing, 11 E Equipotential bonding EB, 12 Explosion hazard, 14 F FM certifications, 33 Functions AFD4, 6 AFD4 (FM), 6 AFD8, 6 AFS, 7 G Grounding, 13 I IECEx approval, 32 INMETRO approval, 32 Installation Drill hole spacing, 11 IP30 cover, 15 K Korea approval, 32 L LED display AFD4 / AFD4 (FM) / AFD8, 29 AFS, 30 Product Information, 02/2015, A5E AC 43

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M

SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation

More information

Siemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Siemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry. Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/

More information

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm 0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device SIMATIC PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device Introduction 1 Preparation 2 Learning units 3 Further Information

More information

SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01

SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified

More information

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Manual 04/2007 A5E01077385-01 Safety Guidelines

More information

1756 ControlLogix Chassis Specifications

1756 ControlLogix Chassis Specifications Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A4K/B, 1756-A4/C, 1756-A4K/C, 1756-A7/B, 1756-A7K/B, 1756-A7/C, 1756-A7K/C, 1756-A10/B, 1756-A10K/B, 1756-A10/C,

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions

More information

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Programming and Operating Manual Validity 1 Improvements in STEP 7 2 SIMATIC Improvements in WinCC 3 Readme Programming and Operating Manual 07/2013 Legal information Warning notice system This manual contains notices you have to observe

More information

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461 D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex

More information

FCS-MBx-SG Megablock series*

FCS-MBx-SG Megablock series* technical datasheet technical datasheet FCS-MBx-SG Megablock series* passive hubs for general purpose, Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2 Overview Description, device design, dimension drawing 1 Power supply Operating Instructions Mounting/Disassembly 2 Mounting position, installation clearances 3 Installation 4 Applications 5 Technical

More information

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DI DC24V (6ES7131-4BF00-0AA0) Manual 04/2007 A5E01077339-01 Safety Guidelines

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20 Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices CES 63 A Series 8579 www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

1788 Linking Device Specifications

1788 Linking Device Specifications Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Manual. Simrad StructureScan LSS-1 Sonar Module. English Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme

Validity 1. Installation 2 SIMATIC. WinCC flexible Tag simulator Update 1. Readme Validity 1 Installation 2 SIMATIC WinCC flexible Readme 05/2011 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well

More information

Instruction Manual. T3111 T3111L T3111P T3111Ex

Instruction Manual. T3111 T3111L T3111P T3111Ex www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical

More information

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:

More information

Plug and Socket Devices SolConeX 16 A Series 8570

Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

Power Supply Guide Version 1.0 for D-Show

Power Supply Guide Version 1.0 for D-Show Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

Sunny Boy Accessories SMA POWER BALANCER

Sunny Boy Accessories SMA POWER BALANCER Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

Differential-Hall-Effect based Sensors Series A5S Overview

Differential-Hall-Effect based Sensors Series A5S Overview A5S Differential-Hall-Effect based Sensors Series A5S Overall View KEY FEATURES Speed range from 0 Hz up to 25 khz (response time < 20 microseconds) Air gap to the target / pole wheel up to 2.5 mm (depending

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en

Mounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical

More information

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry. The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion

More information

MINIMAT-EC-Servo Screwdriver Spindles

MINIMAT-EC-Servo Screwdriver Spindles Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range

More information

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation! 4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Original instructions Tina 3A/Aps Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

Technical Information RIA14

Technical Information RIA14 TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

3DLevelScanner II TECHNICAL DATA SHEET

3DLevelScanner II TECHNICAL DATA SHEET TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

3500/93 System Display

3500/93 System Display 3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Rosemount 752 FOUNDATION fieldbus Remote Indicator Product Data Sheet September 2014 00813-0100-4377, Rev DA Rosemount 752 FOUNDATION fieldbus Remote Indicator Two-wire segment powered device Displays up to eight values Link Master Capability Optional

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information