1 N0/N00, N4/N40 DAMPER ACTUATORS 0/4 Nm (177/00 lb-in) FOR FLOATING / -POSITION CONTROL PRODUCT DATA GENERAL These direct-coupled damper actuats provide two-position and floating control f: air dampers, VAV units, air handlers, ventilation flaps, louvers, and reliable control f air damper applications f up to 4 m (air friction-dependent). FEATURES New self-centering shaft adapter Access cover to facilitate connectivity Declutch f manual adjustment Mechanical end limits Field-installable auxiliary switches Silent drive operation Pre-wired Rotation direction selectable by switch Mountable in any ientation (except upside down) Mechanical position indicat SPECIFICATIONS Supply voltage N0/N4 Vac ±15%, 50 Hz N00/N40 0 Vac ±15%, 50 Hz Nominal voltage N0/N4 Vac, 50 Hz N00/N40 0 Vac, 50 Hz All values stated hereinafter apply to operation under nominal voltage conditions. Power consumption N0/N00 6 VA / W N4/N40 7 VA / 7 W Ambient limits Ambient operating limits C ( F) Ambient stage limits C ( F) Relative humidity %, non-condensing Cables Length 1 m Materials silicone-free Safety Protection standard IP54 as per EN6059 Protection class II as per EN Lifetime Full strokes Repositions 1.5 million Mounting Round damper shaft mm Square damper shaft mm; 45 steps Shaft length min. mm Auxiliary switch (when included) Rating 5 A (resistive) / A (inductive) Triggering points 5 / 85 Tque rating N0/N00 0 Nm (177 lb-in) N4/N40 4 Nm (00 lb-in) Runtime 110 seconds Rotation stroke 95 ± Dimensions see "Dimensions" on page 8 Weight (without cables) 1.45 kg ( lbs. oz.) Noise rating 40 db(a) max. at 1 m По вопросам продаж и поддержки обращайтесь: Астана +7(717)77-1, Волгоград (844) , Воронеж (47) , Екатеринбург (4) , Казань (84) , Краснодар (861) , Красноярск (91) , Москва (495) , Нижний Новгород (81) , Новосибирск (8)7-86-7, Ростов-на-Дону (86) , Самара (846) , Санкт-Петербург (81) , Саратов (845)9-8-78, Уфа (47) Единый адрес: hwn@nt-rt.ru
2 SmartAct N0/N00 DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL MODELS Order number Supply voltage Auxiliary switches Feedback Power consumption Tque N0/N0-POS Vac N0-SW Vac -- N0-P10K Vac Kohm N00/N00-POS 0 Vac VA / W 0 Nm (177 lb-in) N00-SW 0 Vac -- N00-P10K 0 Vac Kohm N4 Vac N40 0 Vac VA / 7 W 4 Nm (00 lb-in) Product Identification System 010 = modulating 0 = 0 Nm = -volt floating/on-off 4 = 4 Nm 0 = 0-volt floating/on-off SmartAct N 0 0X N = no spring return S = spring return If additional elements are required, please complete as follows: -POS = On/Off -F = Fire and Smoke -VAV = Variable Air Volume -LON = LonWks -SER = Enhanced (serial interface + span + offset) -P500 = feedback potentiometer, 500 Ohms -P1000 = feedback potentiometer, 1000 Ohms -P5000 = feedback potentiometer, 5000 Ohms -P10K = feedback potentiometer, 10 kohm -SW = two built-in auxiliary switches = not currently available Fig. 1. Product Identification System OPERATION / FUNCTIONS Legend f Fig. : 1 Self-centering shaft adapter Retainer clip Rotational angle scales ( / ) 4 Mechanical end limits (not applicable f N4xx) 5 Declutch button 6 Anti-rotation bracket 7 Rotation direction switch 8 Access cover 9 Internal auxiliary switch wire 10 Power and control switch wire Contents of Package The delivery package includes the actuat, itself, parts 1 through 10 (see Fig. ), the anti-rotation bracket screws, and the SM mounting plate and screws. Rotary Movement The rotation direction (clockwise counterclockwise) can be selected using the rotation direction switch (see part 7 in Fig. ), thus eliminating the need to re-wire. To ensure tight closing of the dampers, the actuat has a total rotation stroke of 95. Fig.. Setting units and control elements As soon as operating power is applied, the actuat may start to run. When power is removed, the actuat remains in position. F actuat-controller wiring instructions, see section "Wiring" on page 4.
3 SmartAct N0/N00 DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL Rotation Direction Switch Position Indication The hub adapter indicates the rotation angle position by means of the rotational angle scales ( / ) provided in the actuat plate (see Fig. 5). Fig.. Rotation Direction Switch Dir (" ") is the default shipping position. When the rotation direction switch is set to this position, the actuat internally switches the rotation direction control signals as stated in section "Wiring Diagrams" on pages 5 and 6. "Service/Off": When the rotation direction switch is set to this position, all actuat rotary movement is cancelled and all control signals are igned, thus enabling the actuat to be manually operated (see section "Manual Adjustment"). The user can then perfm maintenance / commissioning without having to remove power from the actuat. To return to the control mode, simply move the rotation direction switch to its fmer setting. Rev (" "): When the rotation direction switch is set to this position, the actuat follows signals as stated in section "Wiring Diagrams" on pages 5 and 6. Two-Position Floating Control The actuat is capable of being operated by either a twoposition (open/close) a floating (three-wire) controller. Refer to wiring diagrams f crect connection. Manual Adjustment Fig. 5. Position indication IMPORTANT To prevent equipment damage, you must remove power set the rotation direction switch to the "Service/Off" position befe manual adjustment. After removing power setting the rotation direction switch to the "Service/Off" position, the gear train can be disengaged using the declutch button, permitting the actuat shaft to be manually rotated to any position. The feedback signal will then follow the new position. Limitation of Rotation Stroke Two adjustable mechanical end limits are provided (not applicable f N4xx) to limit the angle of rotation as desired (see Fig. 6). Feedback Signal Actuats equipped with a feedback potentiometer provide position feedback via the potentiometer resistance value (see Fig. 4). P totally CCW totally CW = max. ohm totally CCW = 0 ohm = 0 ohm P totally CW = max. ohm P1 500 Ohm 1 kohm 5 kohm 10 kohm Fig. 6. Mechanical end limits The mechanical end limits must be securely fastened in place as shown in Fig. 7. Specifically, it is imptant that they properly mesh with the rotational angle scales when the screws are tightened. Fig. 4. Feedback signal settings If, while the actuat is not rotating, the user declutches it and manually repositions the shaft adapter, the feedback signal will then follow the new position at which the shaft adapter has been left. Fig. 7. Crect / increct tightening of end limits
4 SmartAct N0/N00 DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL Internal Auxiliary Switches NOTE: Only those actuats f which "-SW" has been specified when dering (e.g.: "N0-SW") feature internal auxiliary switches. The internal auxiliary switches are set to switch from "common" to "nmally open" at angles of 5 and 85, respectively, from the totally counterclockwise position. Self-Centering Shaft Adapter The self-centering shaft adapter can be used f shafts having various diameters ( mm) and shapes (square round). In the case of sht shafts, the shaft adapter may be reversed and mounted on the duct side. Stroke Limitation with Mechanical End Limits The mechanical end limits (not applicable f N4xx) enable the stroke to be limited from in increments of. Wiring Access Cover To facilitate wiring the actuat to the controller, the access cover can be detached from the actuat. Fig. 8. Internal auxiliary switch triggering points INSTALLATION These actuats are designed f single-point mounting. IMPORTANT In der to prevent equipment damage, you must remove power set the rotation direction switch to the "Service/Off" position befe manual operation. Mounting Instructions All infmation and steps are included in the Installation Instructions supplied with the actuat. Mounting Position The actuats can be mounted in any position (except upside down). Choose a mounting position permitting easy access to the actuat's cables and controls. IMPORTANT Remove power befe detaching the access cover. Once the access cover has been removed, please take care to avoid damaging any of the parts now accessible. Fig. 9. Access cover (N0-SW) Depending upon the model, the access cover may have one two terminal strips, including a lay-out with a description f each of the terminals. Mounting Bracket and Screws If the actuat is to be mounted directly on a damper shaft, use the mounting bracket and screws included in the delivery package. Fig. 10. N0-SW with access cover removed 4
5 SmartAct N0/N00 DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL Wiring Diagrams N0 / N0-POS / N4 N0-SW Terminal strip 1 Vac~ brown rotation direction switch Dir Service/Off Rev M ~ Vac~ brown rotation direction switch Dir Service/Off Rev M ~ S1 black S black S black S4 gray S1 S S S4 Auxiliary switches V blue 1 1! Connect via safety isolating transfmer!! Connect via safety isolating transfmer! Two-position control V blue 1 1 Floating control S5 gray S5 S6 gray S6 Auxiliary switches N0-P10K rotation direction switch Dir rotation direction switch Dir P Terminal strip 1 Feedback potentiometer Vac~ V black blue 1 1 Service/Off Rev Two-position control M ~ Vac~ V brown blue 1 1 Floating control Service/Off! Connect via safety isolating transfmer!! Connect via safety isolating transfmer! Rev M ~ totally CCW = max. ohm totally CCW = 0 ohm totally CW = 0 ohm P totally CW = max. ohm P1 500 Ohm 1 kohm 5 kohm 10 kohm Feedback potentiometer Connecting cable Terminal Wire col Wire print Name Floating Two-position Supply and signal lines 1 blue 1 Vac Vac (must be equipped with brown Vac (clockwise) Vac spark suppresss) Vac (counterclockwise) Vac control signal S1 black S1 _ common CCW (left) 5 S black S= nmally closed Auxiliary S black S nmally open switches (when included) S4 gray S4 _ common CW (right) 85 S5 gray S5= nmally closed S6 gray S6 nmally open P1 P1 full clockwise Feedback potentiometer P P signal P P full counterclockwise 5
6 SmartAct N0/N00 DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL N00 / N00-POS / N40 N00-SW N00-P10K Connecting cable Terminal Wire col Wire print Name Floating Two-position Supply and signal lines 1 blue 1 0 Vac 0 Vac (must be equipped with brown 0 Vac (clockwise) 0 Vac spark suppresss) 0 Vac (counterclockwise) 0 Vac control signal S1 black S1 _ common CCW (left) 5 S black S= nmally closed Auxiliary S black S nmally open switches (when included) S4 gray S4 _ common CW (right) 85 S5 gray S5= nmally closed S6 gray S6 nmally open P1 P1 full clockwise Feedback potentiometer P P signal P P full counterclockwise 6
7 SmartAct N0/N00 DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL OPTIONAL ACCESSORIES The following optional accessies can be dered separately. Three-Point Mounting Bracket Kit Order no.: A Allows the actuat to be mounted away from the damper shaft and to be linked by means of the crank arm. Auxiliary Switch Kit Order no.: SW SPARE PARTS Spare Parts Kit Order no.: A The spare parts kit contains the following items: Anti-rotation bracket and screws SM Mounting plate and screws Access cover screw Plastic protective cap f protection standard IP54. Mechanical end limit screw and retainer Anti-Rotation Bracket and Screws Order no.: A The anti-rotation bracket can also be dered separately, and comes complete with two screws. The internal auxiliary switches are field-installable parts providing two SPDT freely-adjustable switches. Security Labels Order no.: A Each packet contains 8 security labels. SM Mounting Plate Order no.: A The SM mounting plate can also be dered separately, and comes complete with screws. Crank Arms Order no.: 0580A Access cover Kit Order no.: WB0 F M0 outlets. 7
8 SmartAct N0/N00 DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL DIMENSIONS По вопросам продаж и поддержки обращайтесь: Астана +7(717)77-1, Волгоград (844) , Воронеж (47) , Екатеринбург (4) , Казань (84) , Краснодар (861) , Красноярск (91) , Москва (495) , Нижний Новгород (81) , Новосибирск (8)7-86-7, Ростов-на-Дону (86) , Самара (846) , Санкт-Петербург (81) , Саратов (845)9-8-78, Уфа (47) Единый адрес: hwn@nt-rt.ru
N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL
N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More information225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
More informationS03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators
S, S Series Low-Torque Spring- Return Direct-Coupled Actuators S, S, S, S, S, S INSTALLATION AND OPERATING INSTRUCTIONS S, S Series Low-Torque Spring-Return Direct-Coupled Actuators (DCA) are used for
More informationM9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,
More informationAir damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V
4 613 OpenAir TM Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V GCA12...1 GCA32...1 Electromotive rotary actuators for two-position control, nominal
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationPower consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point 0...95
Actuators Technical data sheet 227S-230-05-S1 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5
More informationTelefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 mail@uni-valve.com www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
More information225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators
Actuators Technical data sheet 225C-024T-05 Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations.
More informationThis chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.
1/99 Modutrol Motors Selection Guide This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets. 2-POSITION SPRING
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationRotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationEATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.
ENGLISH EATS6 EATS6N Installation and user manual Copyright 05 EATON All rights reserved. Service and suppt: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationInstallation Instructions
0.1.2....6.7..9 1 0.1.2....6.7..9 1 Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its fail-safe position.
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke
More informationQuick running actuator
ACTATOR FOR DAMPERS Quick running actuator Actuator with rotation drive. 4 Nm 8 Nm For the application with Laboratory ventilation techniques Room ventilation techniques VAV Valves Page: Content: 3 4-5
More informationSeries 71, 72, and 76 Modutrol IV Motors
Series 7, 7, and 76 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 7, 7 and 76 Modutrol IV Motors are spring return and nonspring return motors used to control dampers and valves. The
More informationKnow-how makes the difference. Electrical Actuators
Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationSKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
More informationADVERTIS Group Agency presentation
ADVERTIS Group Agency presentation // ADVERTIS Group. Who we are? ADVERTIS is an Advertising and Marketing Agency, specialized in business brands, products and services within Russian Market. Knowledge
More informationTOA 900 SERIES II MIXER POWER AMPLIFIER
Operating Instructions TOA 900 SERIES II MIXER POWER AMPLIFIER A-903MK2 A-906MK2 A-912MK2 TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING
More informationVAV compact controller KNX / PL-Link
s 3 547 OpenAir VAV compact controller KNX / PL-Link Series E GDB181.1E/KN GLB181.1E/KN Networked compact controller featuring KNX (S-mode / LTE-mode) and PL- Link capability for plants with variable air
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationServo Info and Centering
Info and Centering A servo is a mechanical motorized device that can be instructed to move the output shaft attached to a servo wheel or arm to a specified position. Inside the servo box is a DC motor
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationSMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI 52-07 (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA
900 43 Kalinkovo 146 Slovakia Tel.: 00421 /2 /40203111 40203112 Fax: 00421 /2 /45989179 Email: imos@imos.sk http://www.imos.sk SMOKE DAMPERS (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA IMOS-DKI-1
More informationContactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationNEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown
NEX-3004 AUGUST 4, 2015 Fireye NEXUS FX04 and FX04-1 Servo Motor Installation FX04-1 Shown DESCRIPTION This bulletin describes the installation and operating instructions for the FX04 and FX04-1, 3 lb.-ft./
More informationINSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360
INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360 IMPORTANT SAFETY INSTRUCTIONS WARNING! To reduce the risk of injury or death it is important to closely follow all of the following instructions.
More informationTechnote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
More informationVAV compact controller KNX / PL-Link
s 3 547 OpenAir VAV compact controller KNX / PL-Link Series E GDB181.1E/KN GLB181.1E/KN Networked compact controller featuring KNX (S-mode / LTE-mode) and PL- Link capability for plants with variable air
More informationTAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
More informationTECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
More information1115 4G SERIES GOVERNOR. 4-20 ma ANALOGUE DIGITAL SPEED SETTING
1115 4G SERIES GOVERNOR with 4-20 ma ANALOGUE & DIGITAL SPEED SETTING PO Box 28, 9300AA Roden, The Netherlands Tel: +31 505019888 Fax: +31 505013618 E-mail: regulateurs@regulateurs-europa.com 1115 4G
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationActuator for modulating control AME 435
Data sheet Actuator for modulating control AME 435 Description The actuator automatically adapts its stroke to the valve end positions which reduces commissioning time (self stroking). The advanced design
More informationSIMRAD SD10 Sailboat Drive
INSTALLATION MANUAL SIMRAD SD10 Sailboat Drive 20222683/A English Simrad SD10 Sailboat Drive About this document Rev. A First issue 2007 Navico AS. All rights reserved. No part of this work covered by
More informationCONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
More informationSwitch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
More informationOutput torques up to 8000 Nm. General features. Protection. External coating. Working temperature range
Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More informationTechnical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
More informationDS 1.102 DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches
DS 1.102 02/99 AIR ROOM TEMPERATURE SENSOR with fan speed control switches Specification No. 528-X-XXX* The Active Room Temperature sensor incorporating fan speed control switches is designed to give a
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationShutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S 4.230.1, GH Q631 0076 R0111. ABB i-bus EIB
, GH Q631 0076 R0111 2CDC 071 240 F0003 The Shutter Actuator Standard is used to control a maximum of four independent 230 VAC drives for positioning shutters, blinds, awnings and other hangings as well
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationHQ Series ¼ Turn Actuator
HQ Series ¼ Turn Actuator HQ-015 thru HQ-300 Installation & Maintenance Manual HQ Series I&M Manual HQ-400-1005 1 Table of Contents: General 1.0 Actuator Mounting 2.0 External Construction 3.0 Wiring Diagrams
More informationDMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual
DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.
More informationManual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationDPT-2015 Differential Pressure Transmitter for VAV Box Applications
FANs 216, 1628.3 Product/Technical Bulletin DPT-2015 Issue Date 1298 DPT-2015 Differential Pressure Transmitter for VAV Box Applications The DPT-2015 Differential Pressure Transmitter senses differential
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationPRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
More informationDUCT SMOKE DETECTOR D4120
Purpose/Application National and local safety standards and codes recognize the ability of air duct systems to transfer smoke, toxic gases, and flame from area to area. Sometimes smoke can be of such quantity
More informationSPEED CONTROL SYSTEM
SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W
More informationABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1
Product Manual ABB i-bus EIB Shutter Actuators JA/S 2.230.1, JA/S 4.230.1, JA/S 8.230.1, JA/S 4.230.1M, JA/S 8.230.1M, JA/S 4.24.1 Intelligent Installation Systems Contents Page 1 Introduction.......................................
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationHow To Drive A Compact Serie 1
Electric lifting cylinder Compact Series Table of Contents Glossary... 2 Compact serie SR 1... 4 Dimension SR 1... 5 Compact Serie SR 1SP... 6 Dimension SR 1SP... 7 Compact Serie SR 5... 8 Dimension SR
More informationModel 2300DR Installation Guide
Model 2300DR Installation Guide POWER ACCESS CORPORATION P.O. BOX 1050 170 MAIN STREET NEW HARTFORD, CT 06057 800-344-0088 WEBSITE: www.power-access.com EMAIL: salesinfo@power-access.com 1 STANDARD PARTS
More informationOperating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
More informationINSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
More informationFor tailormade safety. Actuators of the 300 series for fire protection and smoke extraction.
For tailormade safety. Actuators of the 300 series for fire protection and smoke extraction. The new performers. Reliable, user-friendly and flexible. Actuators have been a central component of the Gruner
More informationMINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
More informationBARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
More information98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
More informationSeries 90 Modutrol IV Motors
Series 90 Modutrol IV Motors PRODUCT DATA FEATURES APPLICATION The Series 90 Modutrol IV Motors are spring return and non-spring return modulating proportional control motors. Use these motors with controllers
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM
SHIFT INTERLOCK SYSTEM The shift lock system is designed to ensure the proper operation of the automatic transmission. The driver must depress the brake pedal in order to move the gear selector from Park
More informationFisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
More informationSeries 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
More informationRadiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
More informationTPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER
Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER PSUM These technical specifications determinate a range of manufactured sizes and models of fire shutters (further only shutters)
More informationHCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
More informationSX460. Generator Automatic Voltage Regulator Operation Manual
SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationElectri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions
WCAIM2025 (Part 14944) Electri-SAFE DataFlo Digital Electronic Positioner Installation, Operation and Maintenance Instructions MODELS 15 DP 72 - DataFlo Positioner Mounted On 15-72 Electri-SAFE Actuator
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationService Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE
Service Information Calibration & Adjustments CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS Part Number DYN1-10752-000-0-12/24 DYN1-10752-001-0-12/24* DYN1-10753-000-0-12/24
More informationOperation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A
Operation Manual 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A Endoscopy Support Services, Inc. Croton River Executive Park Route 22, Bldg. 3 Brewster, NY 10509
More informationKeyless Entry System With Two Auxiliary Outputs Installation Instructions
Model APS-45B Installation Manual Keyless Entry System With Two Auxiliary Outputs Installation Instructions This Unit Is Intended F Installation In Vehicles With 12 Volt Negative Ground Electrical Systems
More informationDUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry
DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation.
More informationProgrammable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More information