Grundfos solar surface pump

Size: px
Start display at page:

Download "Grundfos solar surface pump"

Transcription

1 GRUNDFOS DATA BOOKLET Grundfos solar surface pump Renewable energy-based water supply systems

2 Grundfos solar surface pump Table of contents 1. MGFlex motor 3 Features and benefits 3 Nameplate 3 Connection terminals (FM 3) Wiring connections Technical data Motor range. System components 9 IO 5 switch box 9 IO 11 switch box 9 Generator 9 3. CRFlex pump 1 Pumped liquids 1 Nameplate 1 System sizing 1 Material specification 11 Product range 1. Applications 13 CRFlex Solar 13 CRFlex Solar with level switch 1 CRFlex Solar with generator 15 CRFlex Solar with level switch and generator 1 CRFlex and SQFlex Solar 1 5. Accessories 1. Technical data 19 Dimensions and weights 19 Electrical data 1. Performance curves Curve conditions CRFlex CRFlex 1-1 CRFlex CRFlex 3-11 CRFlex 5- CRFlex 5- CRFlex CRFlex 1-3 CRFlex Appendix 3 Performance curves, CRI, CRN 1 3 Performance curves, CRI, CRN 3 33 Performance curves, CRI, CRN 5 3 Performance curves, CRI, CRN 1 35 Performance curves, CRI, CRN Further product documentation 3 WebCAPS 3 WinCAPS 3

3 Grundfos solar surface pump 1 1. MGFlex motor The MGFlex motor is a permanent magnet motor. Motor comes with two different sizes: frame size /9 and with integrated frequency converter. The frequency converter enables the motor to run at high efficiency in a wide speed range: power input (P1) of to W and to 13 W motor speed of 1 to 3 min -1 maximum input current of. A and.9 A enclosure class IP55. The motor is suitable for both DC and AC voltage supply: 3-3 VDC, PE 1 x 9- VAC, - 1 %/+ %, 5/ Hz, PE. The MGFlex motor can be mounted on Grundfos CR and MTR (as float pump) pumps. Features and benefits Maximum Power Point Tracking (MPPT) The motor continuously optimises the speed according to the input power available when connected to DC supply. Wide voltage range The wide voltage range enables the motor to operate at any voltage from 3 to 3 VDC or 9 to VAC. Overvoltage and undervoltage protection Overvoltage and undervoltage may occur in case of unstable power supply or a faulty installation. The motor will be stopped if the voltage falls outside the permissible voltage range, and it will be restarted when the voltage is again within the permissible voltage range. Therefore, no additional protection relay is required. Overload protection The motor incorporates thermal protection against both steady overload and stalled condition according to IEC It will be stopped and restarted automatically. MGFlex motor Nameplate Type : P.C.: INPUT OUTPUT VARIANT P.N. : - V Serial no : U in : P : kw PB : DE : Env.Type : IP: ~ V n max: rpm FM : NDE : PF : CL: f in : Hz Eff : HMI: Wgt : kg Tamb : o C I 1/1 : A CIM: Made in Hungary DK - 5 Bjerringbro, Denmark 15 1 TM Fig. 1 Nameplate of the MGFlex motor Pos. Description Pos. Description 1 Type designation 15 Grundfos company address Product number 1 Country of manufacture 3 Drive-end bearing 1 Human Machine Interface type Version number 1 CIM module type 5 Environmental type 19 Motor efficiency Production code (year and week) Max. motor speed [min -1 ] Serial number 1 Max. input current [A] Supply voltage [V] Mains frequency [Hz] 9 Rated power output [kw] 3 Enclosure class according to IEC Power board Insulation class according to IEC Functional module type 5 Max. ambient temperature [ C] 1 CE mark and approvals Power factor 13 Part number of nameplate Weight [kg] 1 Grundfos logo Non-drive-end bearing 3

4 1 Grundfos solar surface pump MGFlex motor Connection terminals (FM 3) The MGFlex motor with advanced functional module (FM 3) has a number of inputs and outputs enabling the motor to be used in advanced applications where many inputs and outputs are required. The FM 3 has these connections: three analog inputs one analog output two dedicated digital inputs two configurable digital inputs or open-collector outputs Grundfos Digital Sensor input and output two Pt1/1 inputs LiqTec sensor inputs two signal relay outputs GENIbus connection. See fig. in page 5. Note: Digital input 1 is factory-set to be start/stop input where open circuit will result in stop. A jumper has been factory-fitted between terminals and. Remove the jumper if digital input 1 is to be used as external start/stop or any other external function. Note: As a precaution, the wires to be connected to the connection groups below must be separated from each other by reinforced insulation in their entire lengths. Inputs and outputs All inputs and outputs are internally separated from the mains-conducting parts by reinforced insulation and galvanically separated from other circuits. All control terminals are supplied by safety extra-low voltage (SELV), thus ensuring protection against electric shock. Signal relay outputs Signal relay 1: LIVE 1) : Mains supply voltages up to 5 VAC can be connected to this output. SELV: The output is galvanically separated from other circuits. Therefore, the supply voltage or safety extra-low voltage can be connected to the output as desired. Signal relay : SELV: The output is galvanically separated from other circuits. Therefore, the supply voltage or safety extra-low voltage can be connected to the output as desired. Mains supply (terminals N, PE, L or L1, L, L3, PE). A galvanically safe separation must fulfil the requirements for reinforced insulation including creepage distances and clearances specified in EN ) LIVE: Low voltage with the risk of electric shock if the terminals are touched.

5 Grundfos solar surface pump 1 Terminal Type Function NC C1 NO NC C NO Normally closed contact Signal relay 1 Common (LIVE or SELV) Normally open contact Normally closed contact Signal relay Common (SELV only) Normally open contact MGFlex motor + V* + V* + V* OC DI + V* + V* + V* + V* + V*/5 V* OC DI + V* GND Fig. Connection terminals, FM V*/5 V* V*/5 V* V* GND + V + V +5 V GND GDS TX GDS RX AI * If an external supply source is used, a connection to GND must be available V* NC C1 NO NC C NO GND DI/OC Pt1/1 Pt1/1 AO GND AI3 DI 1 LiqTec GND LiqTec 1 DI3/OC1 AI1 DI V GND A GENIbus A Y GENIbus Y B GENIbus B TM GND Ground 11 DI/OC Digital input/output, configurable. Open collector: Max. V resistive or inductive. 19 Pt1/1 input Pt1/1 sensor input 1 Pt1/1 input 1 Pt1/1 sensor input 1 AO Analog output: - ma / - ma -1 V 9 GND Ground 1 AI3 Analog input: - ma / - ma -1 V 1 DI Digital input, configurable 1 LiqTec sensor input 1 GND LiqTec sensor input LiqTec sensor input (white conductor) Ground (brown and black conductors) LiqTec sensor input (blue conductor) 1 DI3/OC1 Digital input/output, configurable. Open collector: Max. V resistive or inductive. AI1 Analog input: - ma / - ma V / -5 V / -1 V DI1 Digital input, configurable 5 +5 V Supply to potentiometer and sensor GND Ground A GENIbus, A GENIbus, A (+) Y GENIbus, Y GENIbus, GND B GENIbus, B GENIbus, B(-) 3 GND Ground 15 + V Supply + V Supply +5 V Supply to potentiometer and sensor 3 GND Ground 5 GDS TX Grundfos Digital Sensor output GDS RX Grundfos Digital Sensor input AI Analog input: - ma / - ma V / -5 V / -1 V 5

6 1 Grundfos solar surface pump MGFlex motor Wiring connections Fig. 3 Wiring diagram The motor is to be connected to the power supply as shown in fig. 3. As the integrated electronic unit enables the motor to handle both DC and AC supply voltages, it makes no difference how the wires + and - or N and L are connected. TM TM Fig. Electrical connections, MGFlex motor

7 Grundfos solar surface pump 1 Technical data Dimensions MGFlex motor Fig. 5 Dimensional sketch of MGFlex TM Power [kw] Short type designation Stator housing [mm] Shaft end [mm] IEC: AC AD AE AF L LB LL D DB E EB F G GA DIN: g p1 d d I u t.5 MGEAHA M MGE9CHA M 5 Flange [mm] Cable entries Power [kw] Short type designation IEC: LA M N P S x Z T O DIN: c1 e1 b1 a1 s1 f1.5 MGEAHA M x MGE9CHA M x 3 x M

8 1 Grundfos solar surface pump MGFlex motor Electrical data Power supply to pump Energy source Start/stop control 3-3 VDC, PE. 1 x 9 - V, - 1 %/+ %, 5/ Hz, PE. Solar module. Generator. Grid. Digital input for start/stop of motor. Power switch on/off or DC to/from AC Enclosure class Motor protection Sound pressure level Max. four times per hour. IP55. Built-in motor protection: overvoltage and undervoltage overload overtemperature. < db (A) for.5 kw motor. Power factor.9. Earth-leakage circuit breaker If the pump/motor is connected to an earth-leakage circuit breaker (ELCB) for additional protection, this circuit breaker must trip when AC fault currents, pulsating DC or smooth DC fault currents occur. Ambient temperature During operation: - C to +5 C. During storage/transport: -5 C to + C. Relative humidity Maximum 95 %. Leaking current Installation outdoor < 3.5 ma for AC. < 1 ma for DC. The motor/pump must be protected from rain and direct sunlight. Marking CE. Insulation class F (IEC 5). EMC compatibility EN 1-3. Motor range Product Power P1 [W] Product number MGFlex A 939 MGFlex 9Sc Note Grundfos only guarantees the performance and reliability of the MGFlex motors if both conditions below are fulfilled: 1. The motor must be connected to the pump end as described in this document.. The assembly of the motor and the pump must be carried out by persons trained and authorised by Grundfos. In the case of OEM usage, please contact Grundfos to obtain full warranty coverage.

9 Grundfos solar surface pump. System components IO 5 switch box The IO 5 is designed specifically for solar-powered systems. The IO 5 enables manual starting and stopping of the pump in a solar system and functions as a connection box joining all necessary cables. (1 mm) (15 mm) 3 1/ ( mm) IO 11 switch box The IO 11 is designed specifically for solar-powered systems. The IO 11 enables the connection of a backup generator in case of insufficient solar energy. The switching between solar power and generator must be made manually. In case the generator is stopped manually or runs out of fuel, the IO 11 will automatically change over to the solar panels. The IO 11 functions as a connection box joining all necessary cables System components Fig. Dimensions, IO 5 1 3/ (. mm) 9/1 (115 mm) TM Dimensions stated in mm. 199 TM 5 3 Fig. Dimensions, IO 11 TM 5 1 Fig. Wiring diagram Technical data Voltage Enclosure class Ambient temperature Marking Max. 3 VDC,.9 A. Max. 5 VAC,.9 A. IP55. During operation: -3 C to +5 C. During storage: -3 C to + C. CE. Fig. 9 Electrical connections, IO 11 Technical data Voltage Enclosure class Ambient temperature Marking PE Generator Power Pump 3 VAC - 15 %/+ 1 %, 5/ Hz (internal relay). Max. 5 VDC,.9 A. Max. 5 VAC,.9 A. IP55. During operation: -3 C to +5 C. During storage: -3 C to + C. CE. TM 1 51 Generator The generator can be either diesel or petrol-driven. It must be running steadily before the pump is cut in. 9

10 3 Grundfos solar surface pump CRFlex pump 3. CRFlex pump The CRFlex pump is available as a complete unit only, consisting of these parts: MGFlex motor CRN or CRI pump end. Nameplate Model f n Q Hz min -1 m 3 /h P Hmax H kw m m pmax/tmax bar/ C CCW Technical file no. Serial No. Made in Denmark DK-5 Bjerringbro 9 1 TM Fig. 11 Nameplate of CRFlex pump end Pos. Description 1 Type designation Fig. 1 CRFlex pump Pumped liquids CRFlex pumps are applicable in thin, clean, nonaggressive, non-explosive liquids, not containing solid or long-fibred particles larger than sand grains. ph value: 5-9. Liquid temperature: C to +1 C. Sand content Maximum sand content: ppm. A higher sand content will reduce the pump life considerably due to wear. Salt content The table below shows the resistance of stainless steel to Cl -. The values in the table are based on a pumped liquid with a ph value of 5 to 9. Stainless steel Cl - content [ppm] Liquid temperature [ C] -3 < EN < 3 EN < TM Model 3 Product number Place of production 5 Production code, year and week Rated shaft power [kw] Closed valve head [m] Head at rated flow rate [m] 9 Direction of rotation (CCW = counter-clockwise) 1 Country of production 11 Mains frequency [Hz] 1 Speed [min -1 ] 13 Rated flow rate [m 3 /h] 1 Max. pressure [bar] and temperature [ C] 15 Technical file number 1 Serial number System sizing Grundfos has developed a PC-based sizing tool enabling the sizing of the system. The sizing tool is integrated in Grundfos WinCAPS and covers solarpowered systems. The following three parameters must be known for the sizing of the optimum system: installation location maximum head required quantity of water required. 1

11 Grundfos solar surface pump 3 Minimum inlet pressure, NPSH Calculation of the inlet pressure "H" is recommended in these situations: The liquid temperature is high. The flow is significantly higher than the rated flow. Water is drawn from depths. Water is drawn through long pipes. Inlet conditions are poor. To avoid cavitation, make sure that there is a minimum pressure on the suction side of the pump. The maximum suction lift "H" in metres head can be calculated as follows: H = p b x 1. - NPSH - H f - H v - H s p b = Barometric pressure in bar. (Barometric pressure can be set to 1 bar). In closed systems, p b indicates the system pressure in bar. NPSH * = Net Positive Suction Head in metres head. (To be read from the NPSH curve at the highest flow the pump will be delivering.) H f = Friction loss in suction pipe in metres head. (At the highest flow the pump will be delivering.) H v = Vapour pressure in metres head. (To be read from the vapour pressure scale."h v " depends on the liquid temperature "T m ".) H s = Safety margin = minimum.5 metres head. If the calculated "H" is positive, the pump can operate at a suction lift of maximum "H" metres head. If the calculated "H" is negative, an inlet pressure of minimum "H" metres head is required. * For NPSH curves, see section. Appendix. H Hf Pb Hv NPSH tm ( C) Hv (m) , 9, 5,, 3,, 1,5 5 1,,, 3,,3, 1,1 TM Material specification Sectional drawing Fig. 13 Sectional drawing of CRFlex pump end Pump materials 1) Stainless steel available on request. ) CRI(E), CRN(E) 1S, 1, 3, 5. 3) Pos. Designation Materials EN/DIN AISI/ASTM 1 Pump head Pump head cover 3 Shaft Stainless steel CRI(E), CRN(E) 1, 15,. Cast iron EN-GJL- 1) EN-JL13 ASTM 5B Stainless steel 1. CF M eq. to AISI ) AISI ) AISI 39 Base Stainless steel 1. 9 Neck ring PTFE 1 Shaft seal Cartridge type TM CF M eq. to AISI Base plate Cast iron EN-GJL- 1) EN-JL13 ASTM 5B Rubber parts EPDM or FKM CRI(E) Impeller Stainless steel 1.31 AISI 3 5 Chamber Stainless steel 1.31 AISI 3 Sleeve Stainless steel 1.31 AISI 3 O-ring for sleeve EPDM or FKM CRN(E) Impeller Stainless steel 1.1 AISI 31 5 Chamber Stainless steel 1.1 AISI 31 Sleeve Stainless steel 1.1 AISI O-ring for sleeve EPDM or FKM 11 CRFlex pump Fig. 1 Minimum inlet pressure - NPSH Note: To avoid cavitation, never select a pump with a duty point too far to the right on the NPSH curve. Always check the NPSH value of the pump at the highest possible flow rate. 11

12 3 Grundfos solar surface pump CRFlex pump Product range The CRFlex pump complete is supplied with a -metre cable. Product Stainless steel Pump end Product number CRIF 1-9 AISI 3/EN 1.31 CRI 913 CRIF 3-5 AISI 3/EN 1.31 CRI 91 CRIF 5- AISI 3/EN 1.31 CRI 91 CRIF 1-1 AISI 3/EN 1.31 CRI 9199 CRIF 1-1 AISI 3/EN 1.31 CRI 911 CRIF 3-11 AISI 3/EN 1.31 CRI 919 CRIF 5- AISI 3/EN 1.31 CRI 91 CRIF 1- AISI 3/EN 1.31 CRI 91 CRIF 15-1 AISI 3/EN 1.31 CRI 911 CRNF 1-9 AISI 31/EN 1.1 CRN 915 CRNF 3-5 AISI 31/EN 1.1 CRN 9159 CRNF 5- AISI 31/EN 1.1 CRN 9159 CRNF 1-1 AISI 31/EN 1.1 CRN 9153 CRNF 1-1 AISI 31/EN 1.1 CRN CRNF 3-11 AISI 31/EN 1.1 CRN CRNF 5- AISI 31/EN 1.1 CRN CRNE 1- AISI 31/EN 1.1 CRN CRNF 15-1 AISI 31/EN 1.1 CRN

13 Grundfos solar surface pump. Applications The Grundfos solar surface pump system is designed for renewable energy supply. Powered by a solar panel, the system is especially suitable for supplying water in applications such as: irrigation watering of livestock pressure boosting floating pump recirculation of swimming-pool water (OEM). Applications CRFlex Solar The CRFlex Solar is the simplest system utilising solar energy for water transfer. Benefits Thanks to the intelligent MGFlex motor, no further motor protection is required. By means of an IO 5, the power supply to the pump can be switched off manually in cases such as these: There is no need for water supply. The system requires service. The system also offers these benefits: easy installation maintenance confined to periodic cleaning of the solar panels few and simple components. Note 1. To calculate the number of solar panels required, please use the sizing tools in Grundfos WinCAPS or WebCAPS.. The vertical distance between the inlet of the CRFlex pump and the dynamic level of the water source must be less than metres. See also section Minimum inlet pressure, NPSH on page The CRFlex pump must be protected against rain and direct sunlight Fig. 1 CRFlex Solar Pos. Description 1 CRFlex pump Solar panels 3 Support structure IO 5 switch box 5 Water pipe Dry-running switch (optional) Non-return valve TM

14 Grundfos solar surface pump Applications CRFlex Solar with level switch The CRFlex Solar system allows solar energy to be stored as water in a reservoir in cases such as these: Water supply is needed at night. For short periods, the solar energy is insufficient to run the pump. There is a need for a backup water source. 5 Benefits Connected directly to the electronics box on the MGFlex motor, the level switch will stop the pump when the water reservoir is full. The system also offers these benefits: easy installation maintenance confined to periodic cleaning of the solar panels few and simple components Note 1. To calculate the number of solar panels required, please use the sizing tools in Grundfos WinCAPS or WebCAPS.. The vertical distance between the inlet of the CRFlex pump and the dynamic level of the water source must be less than metres. See also section Minimum inlet pressure, NPSH on page The CRFlex pump must be protected against rain and direct sunlight. Fig. 15 CRFlex Solar with level switch Pos. Description 1 CRFlex pump TM Solar panels 3 Support structure IO 5 switch box 5 Water reservoir Level switch Water pipe Dry-running switch (optional) 9 Non-return valve 1

15 Grundfos solar surface pump CRFlex Solar with generator During periods of insufficient solar energy, the CRFlex Solar system provides a reliable water supply. The system is connected to an external backup generator via the IO 11 and will automatically switch to operation via generator when the generator is started. If the generator is stopped manually or runs out of fuel, the IO 11 will automatically change back to operation via solar energy. 3 5 Applications Benefits The system offers water supply during the night or during periods of insufficient solar energy. The system also offers these benefits: easy installation maintenance confined to periodic cleaning of the solar panels few and simple components flexible energy supply. 1 Note 1. To calculate the number of solar panels required, please use the sizing tools in Grundfos WinCAPS or WebCAPS.. The vertical distance between the inlet of the CRFlex pump and the dynamic level of the water source must be less than metres. See also section Minimum inlet pressure, NPSH on page The CRFlex pump must be protected against rain and direct sunlight. Fig. 1 CRFlex Solar with generator Pos. Description 1 CRFlex pump Solar panels 3 Support structure TM Diesel or petrol-driven generator 5 IO 11 switch box Water pipe Dry-running switch (optional) Non-return valve 15

16 Grundfos solar surface pump Applications CRFlex Solar with level switch and generator During periods of insufficient solar energy, the CRFlex Solar system will provide a reliable water supply. The supply of water is ensured by a diesel or petroldriven generator connected to the system via the IO 11. The system will automatically switch to operation via generator when the generator is started. If the generator is stopped manually or runs out of fuel, the IO 11 will automatically change back to operation via solar energy. Benefits The system offers water supply during the night or during periods of insufficient solar energy. The system also offers these benefits: easy installation maintenance confined to periodic cleaning of the solar panels few and simple components flexible energy supply. Note 1. To calculate the number of solar panels required, please use the sizing tools in Grundfos WinCAPS or WebCAPS.. The vertical distance between the inlet of the CRFlex pump and the dynamic level of the water source must be less than metres. See also section Minimum inlet pressure, NPSH on page The CRFlex pump must be protected against rain and direct sunlight Fig. 1 CRFlex Solar with level switch and generator Pos. Description 1 CRFlex pump Solar panels 3 Support structure IO 11 switch box 5 Water reservoir Level switch Water pipe Dry-running switch (optional) 9 Non-return valve 1 Diesel or petrol-driven generator 5 1 TM

17 Grundfos solar surface pump CRFlex and SQFlex Solar In addition to enabling customers to store solar energy as water in a reservoir, it offers pressure boosting. Benefits The SQFlex pumps water from wells as small as 3" and stores it in a reservoir. The CRFlex pump transfers water over a long distance or increases the water pressure. Combined with a CU, the level switch will stop the SQFlex when the reservoir is full. The CU offers the following indications: full water reservoir (level switch activated) pump operation input power. The CU indicates operational stoppage in these cases: dry running insufficient energy supply. The system also offers these benefits: easy installation maintenance confined to periodic cleaning of the solar panels few and simple components See the SQFlex data booklet in WebCAPS for further information Fig. 1 CRFlex and SQFlex Solar 3 TM Applications Note 1. To calculate the number of solar panels required, please use the sizing tools in Grundfos WinCAPS or WebCAPS.. The vertical distance between the inlet of the CRFlex pump and the dynamic level of the water source must be less than metres. See also section Minimum inlet pressure, NPSH on page The CRFlex pump must be protected against rain and direct sunlight. Pos. Description 1 CRFlex pump Solar panels 3 Support structure CU control unit 5 Water reservoir Level switch Water pipe IO 5 switch box 9 SQF pump 1

18 5 Grundfos solar surface pump Accessories 5. Accessories IO 5 switch box Description Product number IO 5 (metric) 9953 IO 5 (US) 9959 IO 11 switch box Description Product number IO 11 (3 V) 95 IO 11 (115 V) 915 Dry-running switch Description Product number Dry-running switch Level switch Description Product number Level switch (normally closed) 9911 Level switch (normally open) 1 1

19 Grundfos solar surface pump. Technical data Dimensions and weights CRIF/CRNF 1-9, 1-1 Technical data D D1 B1 B G 1/ G 1/ P (PJE) FGJ (DIN-ANSI-JIS) PN 5 / DN 5/3 CA (FlexiClamp) G 1/ x ø13 ø1 19 x ø ø5 ø3 ø9 ø15 ø1 5 ø59 1 ø3 TM3 1 5 Fig. 19 Dimensional sketch of CRIF/CRNF 1-9, 1-1 Pump type Product number CRIF/CRNF 3-5, 3-11 Dimensions [mm] B1 B1 + B D1 D Net weight [kg] Gross weight [kg] Shipping volume [m 3 ] CRIF CRIF CRNF CRNF D D1 B1 B G 1/ G 1/ P (PJE) FGJ (DIN-ANSI-JIS) PN 5 / DN 5/3 CA (FlexiClamp) G 1/ x ø13 ø1 19 x ø ø5 ø3 ø9 ø15 ø1 5 ø59 1 ø3 TM3 1 5 Fig. Dimensional sketch of CRIF/CRNF 3-5, 3-11 Pump type Product number Dimensions [mm] B1 B1 + B D1 D Net weight [kg] Gross weight [kg] Shipping volume [m 3 ] CRIF CRIF CRNF CRNF

20 Grundfos solar surface pump Technical data CRIF/CRNF 5-, 5- D D1 B1 B G 1/ G 1/ D3 P (PJE) FGJ (DIN-ANSI-JIS) PN 5 / DN 5/3 CA (FlexiClamp) G 1/ x ø13 ø1 19 x ø ø5 ø3 ø9 ø15 ø1 5 ø59 1 ø3 TM3 1 5 Fig. 1 Dimensional sketch of CRIF/CRNF 5-, 5- Pump type Product number CRIF/CRNF 1-1, 1- Dimensions [mm] B1 B1 + B D1 D Net weight [kg] Gross weight [kg] Shipping volume [m 3 ] CRIF CRIF CRNF CRNF D D1 B G 1/ G 1/ D3 P (PJE) FGJ (DIN-ANSI-JIS) PN 1-5 / DN CA (Flexiclamp) B1 G 1/ x ø13 G 1/ 1.5 x ø.1 15 ø115 ø15 13 ø 13 ø15 15 ø 15 ø5 x ø13 TM Fig. Dimensional sketch of CRIF/CRNF 1-1, 1- Pump type Product number Dimensions [mm] B1 B1 + B D1 D Net weight [kg] Gross weight [kg] Shipping volume [m 3 ] CRIF CRIF CRNF CRNE

21 Grundfos solar surface pump CRIF/CRNF 15-1 B D D1 Technical data G 1/ G 1/ D3 P (PJE) FGJ (DIN-ANSI-JIS) PN 1-5 / DN5 CA (Flexiclamp) B1 G 1/ x ø13 G 1/ 1.5 x ø1 ø15 9 ø 13 1 ø ø5 ø ø5 TM3 1 5 Fig. 3 Dimensional drawing sketch of CRIF/CRNF 15-1 Pump type Product number Dimensions [mm] B1 B1 + B D1 D Net weight [kg] Gross weight [kg] Shipping volume [m 3 ] CRIF CRNF Electrical data 3-3 VDC or 1 x 9- VAC, 5/ Hz Pump type Product number Motor type Maximum power input P1 [W] Maximum current [A] Pump type Product number Motor type Maximum power input P1 [W] CRIF MGFlex. CRNF MGFlex. CRIF MGFlex. CRNF MGFlex. CRIF 5-91 MGFlex. CRNF MGFlex. CRIF MGFlex. CRNF MGFlex. CRIF MGFlex 13.9 CRNF MGFlex 13.9 CRIF MGFlex 13.9 CRNF MGFlex 13.9 CRIF 5-91 MGFlex 13.9 CRNF MGFlex 13.9 CRIF 1-91 MGFlex 13.9 CRNE MGFlex 13.9 CRIF MGFlex 13.9 CRNF MGFlex 13.9 Maximum current [A] 1

22 Performance curves Grundfos solar surface pump Curve conditions. Performance curves Curve conditions Specific performance charts The specific performance charts on pages to 31 are based on the following guidelines: Tolerances to ISO 99, Annex A, if indicated. All curves show mean values. The curves must not be used as guarantee curves. Typical deviation: ± 15 %. The measurements have been made at a water temperature of + C. The curves apply to a kinematic viscosity of 1 mm /s (1 cst). If the pump is used for liquids with a viscosity higher than that of water, this will reduce the head and increase the power consumption. Pressure loss The QH curves are inclusive of inlet and valve losses at actual speed. NPSH curves The NPSH curve is an average curve for all the variants shown. When sizing the pumps, add a safety margin of at least.5 m.

23 Grundfos solar surface pump Performance curves CRFlex 1-9 Q [m³/h].5 CRFlex 1-9 CRFlex m 1 m m 3 m m 5 m m. m m P1 [W] TM Fig. Performance curves, CRFlex 1-9 3

24 Performance curves Grundfos solar surface pump CRFlex 1-1 CRFlex 1-1 Q [m³/h]. CRFlex 1-1 m m m m 1 m 1 m m m P1 [W] TM Fig. 5 Performance curves, CRFlex 1-1

25 Grundfos solar surface pump Performance curves CRFlex 3-5 Q [m³/h] CRFlex 3-5 CRFlex m 1 m 15 m m 5 m 3 m 35 m 3 m 5 m P1 [W] TM Fig. Performance curves, CRFlex 3-5 5

26 Performance curves Grundfos solar surface pump CRFlex 3-11 CRFlex 3-11 Q [m³/h] CRFlex m 1 m m 3 m m 5 m m m m 3 9 m 1 m P1 [W] TM Fig. Performance curves, CRFlex 3-11

27 Grundfos solar surface pump Performance curves CRFlex 5- Q [m³/h] 13 CRFlex 5- CRFlex m m m m 1 m 1 m 1 m 1 m 5 1 m P1 [W] TM Fig. Performance curves, CRFlex 5-

28 Performance curves Grundfos solar surface pump CRFlex 5- CRFlex 5- Q [m³/h] 1 CRFlex m 5 m 1 m 15 m m m 5 m 3 m 35 m 5 m 5 55 m P1 [W] TM5 13 Fig. 9 Performance curves, CRFlex 5-

29 Grundfos solar surface pump Performance curves CRFlex 1-1 Q [m³/h] CRFlex 1-1 CRFlex m m m 1 1 m m 1 m P1 [W] TM Fig. 3 Performance curves, CRFlex 1-1 9

30 Performance curves Grundfos solar surface pump CRFlex 1- CRFlex 1- Q [m³/h] CRFlex m 1 m 15 m m 1 5 m P1 [W] TM5 13 Fig. 31 Performance curves, CRFlex 1-3

31 Grundfos solar surface pump Performance curves CRFlex 15-1 Q [m³/h] 3 CRFlex 15-1 CRFlex m m 1 m 1 m 1 m 1 m 1 1 m P1 [W] TM Fig. 3 Performance curves, CRFlex

32 Appendix Grundfos solar surface pump Performance curves, CRI, CRN 1. Appendix Performance curves, CRI, CRN 1 p [kpa] 1 H [m] CRI, CRN 1 Hz ISO 99:1999 Annex A Q [m³/h] Q [l/s] P [kw] H Q [m³/h] NPSH [m] [m] 1 QH 35 rpm NPSH Q [m³/h] Eta P Eta [%] TM Fig. 33 Performance curves, CRI, CRN 1 3

33 Grundfos solar surface pump Appendix Performance curves, CRI, CRN 3 p [kpa] H [m] CRI, CRN 3 Hz ISO 99:1999 Annex A Performance curves, CRI, CRN Q [m³/h] Q [l/s] P [kw].1 P Eta [%].. Eta. H [m] Q [m³/h] QH 35 rpm NPSH [m] 3 NPSH Q [m³/h] TM Fig. 3 Performance curves, CRI, CRN 3 33

34 Appendix Grundfos solar surface pump Performance curves, CRI, CRN 5 Performance curves, CRI, CRN 5 p [kpa] 1 1 H [m] CRI, CRN 5 Hz ISO 99:1999 Annex A Q [m³/h] Q [l/s] P [kw]..1. P Eta Eta [%]. H [m] Q [m³/h] QH 35 rpm NPSH [m] 3 NPSH Q [m³/h] TM Fig. 35 Performance curves, CRI, CRN 5 3

35 Grundfos solar surface pump Appendix Performance curves, CRI, CRN 1 p [kpa] H [m] CRI, CRN 1 Hz ISO 99:1999 Annex A Performance curves, CRI, CRN Q [m³/h] Q [l/s] P [kw].... Eta P Eta [%]. H [m] Q [m³/h] NPSH [m] 35 rpm NPSH Q [m³/h] TM Fig. 3 Performance curves, CRI, CRN 1 35

36 Appendix Grundfos solar surface pump Performance curves, CRI, CRN 15 Performance curves, CRI, CRN 15 p [kpa] 1 H [m] CRI, CRN 15 Hz ISO 99:1999 Annex A Q [m³/h] Q [l/s] P [kw] 1. Eta Eta [%] 1... P. H [m] Q [m³/h] NPSH [m] 35 rpm 1 5 NPSH Q [m³/h] TM Fig. 3 Performance curves, CRI, CRN 15 3

37 Grundfos solar surface pump 9 9. Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on WebCAPS contains detailed information on more than 15, Grundfos products in more than languages. In WebCAPS, all information is divided into sections: Catalogue Literature Service Sizing Replacement CAD drawings. Further product documentation Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P, etc.) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures, etc. Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 3

38 1 9 Grundfos solar surface pump Further product documentation Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download -dimensional (D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: -dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 15, Grundfos products in more than languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 3 WinCAPS CD-ROM Subject to alterations. 3

39 39

40 ECM: The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. Copyright Grundfos Holding A/S GRUNDFOS A/S DK-5 Bjerringbro. Denmark Telephone:

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

GRUNDFOS DATA BOOKLET. SQFlex. Renewable-energy-based water supply systems. 50/60 Hz

GRUNDFOS DATA BOOKLET. SQFlex. Renewable-energy-based water supply systems. 50/60 Hz GRUNDFOS DATA BOOKLET SQFlex Renewable-energy-based water supply systems 50/60 Hz SQFlex Table of contents 1. Product data 3 Performance range 3 Applications 4 SQFlex system 4 Type keys 6 Pumped liquids

More information

CR, CRI, CRN, CRE, CRIE, CRNE

CR, CRI, CRN, CRE, CRIE, CRNE Lenntech info@lenntech.com www.lenntech.com GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 5 z CR, CRI, CRN, CRE, CRIE, CRNE Table of contents 1. Product data

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

GRUNDFOS PRODUCT GUIDE. SQFlex. Renewable-energy based water supply systems 50/60 Hz

GRUNDFOS PRODUCT GUIDE. SQFlex. Renewable-energy based water supply systems 50/60 Hz GRUNDFOS PRODUCT GUIDE SQFlex Renewable-energy based water supply systems 0/60 Hz SQFlex Table of contents 1. Product data 3 Introduction 3 Applications Features and benefits Performance range 7 System

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

CRK 2-130 A-W-A-BUBV 85805906

CRK 2-130 A-W-A-BUBV 85805906 GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html

More information

MTR, MTRE, SPK, MTH, MTA

MTR, MTRE, SPK, MTH, MTA GRUNDFOS DATA BOOKLET MTR, MTRE, SPK, MTH, MTA Immersible pumps 5/6 Hz MTR, MTRE, SPK, MTH, MTA Table of contents 1. Introduction 3 2. Applications 4 3. Performance range 6 MTR, 5 Hz 6 MTRE, 5 Hz 6 MTR,

More information

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1

Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1 Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing

More information

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps GRUNDFOS DATA BOOKLET MAGNA, UPE Series circulator pumps Contents Product data MAGNA/UPE 3 Duty range 3 Characteristic features 3 Benefits 3 Applications 3 eating systems 3 Pumped liquids 3 Type key Performance

More information

LC/LCD ranges level controllers

LC/LCD ranges level controllers GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

GRUNDFOS INSTRUCTIONS. CR Monitoring. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. CR Monitoring. Installation and operating instructions GRUNDFOS INSTRUCTIONS CR Monitoring Installation and operating instructions Declaration of Conformity We Grundfos declare under our sole responsibility that the product CR Monitor, to which this declaration

More information

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz

VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,

More information

Multistage high-pressure multistage centrifugal pumps

Multistage high-pressure multistage centrifugal pumps Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,

More information

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps

No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps grundfos se & sl ranges Submersible and dry-installed wastewater pumps 0.9-30 kw 2, 4, 6 pole 50Hz No compromise Highest total efficiency wastewater pumping ULTIMATE WASTEWATER PUMPING TECHNOLOGY The renewed

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS. Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Series description: Wilo-Yonos MAXO

Series description: Wilo-Yonos MAXO 16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Flygt 3068, 50Hz. Technical Specification

Flygt 3068, 50Hz. Technical Specification Flygt 3068, 50Hz Technical Specification Table of Contents Table of Contents B-pump...2 Product description...2 Motor rating and performance curves...4 C-pump...6 Product description...6 Motor rating

More information

How To Use The Vacon 0 Machinery

How To Use The Vacon 0 Machinery vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25

More information

High-efficiency photovoltaic module using silicon nitride multicrystalline silicon cells. 1000V (TÜV Rheinland rating) 1000V (IEC 61215 rating)

High-efficiency photovoltaic module using silicon nitride multicrystalline silicon cells. 1000V (TÜV Rheinland rating) 1000V (IEC 61215 rating) 135 Watt Photovoltaic Module BP 3135 High-efficiency photovoltaic module using silicon nitride multicrystalline silicon cells. Performance Rated power (P max) Power tolerance Nominal voltage Limited Warranty

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Series description: Wilo-Yonos MAXO-D

Series description: Wilo-Yonos MAXO-D ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Liquid Level Limit Switch liquiphant T FTL 20

Liquid Level Limit Switch liquiphant T FTL 20 Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Non-invasive CLAMP-ON ultrasonic flowmeter for liquids Model CU100: non-invasive installation flowmeter, with transducers installed outside the pipe Installation in horizontal or vertical pipe Easy and

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

The conditions below apply to the curves shown on the following pages.

The conditions below apply to the curves shown on the following pages. GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

extreme applications as standard

extreme applications as standard grundfos INDUSTRY The insurmountable CR extreme applications as standard THE unsurmountable CR A company you can trust Back in 1971 Grundfos shocked the pump world with the introduction of the CR30 - the

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

PS1800 Centrifugal Pumping Systems

PS1800 Centrifugal Pumping Systems PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)

VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01) VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

Catalogue Wilo- Stratos PARA

Catalogue Wilo- Stratos PARA Heating, ir Condition, Cooling, Geothermal heat, Solar heat 25-50W 100W 200W Catalogue Wilo- Stratos PR Wilo-Stratos PR 15/1-5; 20/1-5; 25/1-5; 30/1-5 Wilo-Stratos PR 15/1-7; 20/1-7; 25/1-7; 30/1-7 Wilo-Stratos

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24 Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Standard offering (pumps)

Standard offering (pumps) MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy). HYDRAULIC MACHINES Used to convert between hydraulic and mechanical energies. Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE. SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

T U R B I N E G A S M E T E R

T U R B I N E G A S M E T E R TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =

More information

Series description: Wilo-Star-Z

Series description: Wilo-Star-Z H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry

More information

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: advanced soft start and soft stop control protection functions that operate even when

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information