1 contact actuation position per direction. Page 5/ contact actuation position per direction _1. Page 5/124

Size: px
Start display at page:

Download "1 contact actuation position per direction. Page 5/ contact actuation position per direction _1. Page 5/124"

Transcription

1 Presentation Osiswitch Classic For hoisting and mechanical handling applications, types XCR and XCK MR For conveyor belt shift monitoring, type XCR T b XCR v With head for rotary movement operators, spring return to off position contact actuation position per direction 0 Page / v With head for rotary movement operators, stay put contact actuation position per direction 00_ b XCK MR Page / v With head for rotary movement operators, stay put contact actuation positions contact per position: + 0, + 0, - 0 and _ Page /0 b XCR T v With head for rotary movement operators, spring return to off position contact actuation positions per direction actuated at 0, other contact actuated at 0 Page / /

2 General characteristics Osiswitch Classic For hoisting and mechanical handling applications, types XCR and XCK MR For conveyor belt shift monitoring, type XCR T Environment characteristics Conforming to standards Products IEC/EN 0--, VDE (CSA C- n for XCR), CCC (for XCR) Machine assemblies IEC/EN 00-, NF C -0 Product certifications Standard version XCR A, B, E, F: CSA A00 Special version XCR A, B, E, F: CSA A00, / NPT Protective treatment Standard version TC Ambient air temperature Operation C Storage C (+ C for XCK MR) Vibration resistance XCR: gn (0 00 Hz), XCK MR: gn (0 00 Hz) conforming to IEC 00-- Shock resistance XCR A, B, E, F: gn, XCR T: 0 gn ( ms), XCK MR: 0 gn conforming to IEC 00-- Electric shock protection Class I conforming to IEC 0 and NF C 0-00 Degree of protection XCR A, B, E, F: IP conforming to IEC 0 ; IP conforming to NF C 0-00 XCR T: IP conforming to IEC 0 ; IP conforming to NF C 0-00 XCK MR: IP conforming to IEC 0 ; IP conforming to NF C 0-00 Enclosure XCR and XCK MR: metal, except XCR T: polyester Cable entry XCR: tapped entry for n (Pg.) cable gland XCK MR: tapped entries for n (Pg.) cable gland or tapped M0 x. Contact block characteristics Rated operational characteristics a AC- ; A00 (Ue 0 V, Ie A) c DC- ; XCR: Q00 (Ue 0 V, Ie 0. A), XCK MR: Q0 (Ue V, Ie 0. A), conforming to IEC 0-- Appendix A, EN 0-- Rated insulation voltage Ui 00 V degree of pollution conforming to IEC 0- and VDE 00, group C conforming to NF C 0-00 Ui 00 V conforming to UL 0, CSA C- n Rated impulse withstand voltage U imp kv conforming to IEC 0-, IEC 0 Positive operation (Depending on model) N/C contacts with positive opening operation to IEC 0-- Section, EN 0-- (contacts of XCK MR) Resistance across terminals mω conforming to NF C -00 method A or IEC 0- category Short-circuit protection 0 A cartridge fuse type gg (gl) Cabling Screw clamp terminals XES P: Clamping capacity, min: x 0., max: x. XEN P: Clamping capacity, min: x 0., max: x. XCR T contacts: Clamping capacity, min: x 0., max: x. XCK MR contacts: Clamping capacity, min: x 0., max: x. or x. Minimum actuation speed Electrical durability a.c. supply a 0/0 Hz inductive circuit XES P and XCR T contacts: 0.0 m/minute, XEN P and XCK MR contacts: m/minute b Conforming to IEC 0-- Appendix C b Utilisation categories AC- and DC- b Maximum operating rate: 00 operating cycles per hour b Load factor: 0. XES P XEN P Millions of operating cycles 0, 0 V 0/00 V V V Ithe Millions of operating cycles 0, 0, 0 V // V 0 V Ithe 0, 0, 0 Current in A XCR T contacts Millions of operating cycles Ithe / V 0 V V 0, 0, 0, 0 Current in A 0, 0 V 0, 0 Current in A d.c. supply c Voltage V 0 Power broken in W for XES P 0 million operating cycles XEN P W XCR T contacts 0 For XES P on a or c N/C and N/O contacts simultaneously loaded to the values shown with reverse polarity. 0 /

3 References, characteristics Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with cable entry Type of head Rotary with spring return to off position Stay put Maximum displacement in each direction 0 in each direction Type of operator Metal rod, U Thermoplastic roller lever References of complete switches ( Two -pole N/C + N/O XES P st contact nd contact Both contacts operate in each direction contact operates in each direction () Crossed rods for XCR Ep, T rods for XCR Fp. N/C contact with positive opening operation) Large thermoplastic roller lever Metal rods, U crossed or T () XCR A XCR A XCR A XCR E 0 (P) 0 0 (P) () () 0 (P) 0 0 (P) () () XCR B XCR B XCR B XCR F (P) 0 (P) 0 0 () () (P) 0 (P) 0 0 () () 0 (P) 0 0 (P) (P) 0 (P) 0 0 () () () () (P) 0 (P) 0 0 (P) (P) 0 (P) 0 0 () () () () Two -pole N/C + N/O Both contacts operate in each break before make, slow break direction XEN P st contact nd contact contact operates in each direction XCR A XCR A XCR A XCR E () () () XCR B XCR B XCR B XCR F () () () () () () () () () () () () () Weight ().0... Contact operation contact closed (P) positive opening point contact open () st contact () nd contact Complementary characteristics not shown under general characteristics (page /) Maximum actuation speed. m/s Mechanical durability 0 million operating cycles Minimum torque For tripping 0. N.m 0.0 N.m For positive opening 0. N.m 0.0 N.m Cable entry entry tapped for n cable gland conforming to NF C -00 (DIN Pg.) Clamping capacity to 0 Dimensions: page / /

4 References (continued) Osiswitch Classic For hoisting and materials handling applications, type XCR Separate components Description Rod, U For switches XCR A XCR B Type Reference Weight L 00 XCR Z L 00 XCR Z XCR Z0 XCR Z0 Roller lever thermoplastic roller XCR A XCR B XCR Z Large roller lever thermoplastic roller XCR A XCR B Quick fixing/release XCR A, XCR B bracket XCR E, XCR F XCR Z XCR Z0 0.0 XCR Z0 XCR Zp Contact block ( contacts) with mounting plate XCR A, XCR B XCR E, XCR F -pole N/C + N/O -pole N/C + N/O break before make, slow break XCR Z 0. XCR Z 0. Description Application Sold in lots of Unit reference Weight Adaptor Pg. to ISO M0 x. DE RA Dimensions: page / /

5 References, characteristics Osiswitch Classic For conveyor belt shift monitoring applications, type XCR T Complete switches with cable entry Type of switch Standard For corrosive atmospheres Features Zinc alloy enclosure Colour: industrial blue Zinc plated steel lever, spring return to off position Cam angles: 0 and Maximum displacement: 0 Zinc alloy enclosure Colour: blue Stainless steel lever, spring return to off position Cam angles: 0 and Maximum displacement: 0 References of complete switches single-pole C/O XCR T XCR T XCR T Glass reinforced polyester enclosure Colour: grey Stainless steel lever, spring return to off position Cam angles: 0 and Maximum displacement: 0 st contact nd contact Weight () Contact operation contact closed contact open Complementary characteristics not shown under general characteristics (page /) Mechanical durability Minimum tripping torque million operating cycles N.m Cable entry entry tapped for n cable gland conforming to NF C -00 (DIN Pg.) Clamping capacity to Switch operation Normal position Fault signalling Stopping of the conveyor belt Maximum rotation Dimensions: page / /

6 References (continued) Osiswitch Classic For conveyor belt shift monitoring applications, type XCR T Separate components Description Type For switches Roller with lever Zinc plated steel XCR T XCR T Reference Weight XCR Z0 0.0 XCR Zpp Stainless steel XCR T XCR T XCR Z0 0.0 XCR T XCR Z0 0.0 Quick fixing/release bracket XCR T XCR T Contact block ( contacts) Single-pole C/O with mounting plate XCR Z0 0.0 XCR Tp XCR Z 0. XCR Z0 Description Application Sold in lots of Adaptor Pg. to ISO M0 x. Unit reference Weight DE RA XCR Z 0 Dimensions: page / /

7 Dimensions Osiswitch Classic For hoisting and materials handling applications, type XCR XCR A, B, A, B XCR A, B, A, B 0 () () () () XCR A, B, A, B XCR E, E, F, F () 0 () () () () tapped entry for n cable gland. () Rod length: 00. () Rod + roller length: 0. () Rod length: 00 for XCR F and F, 00 for XCR E and E. Supplementary fixing using adjustable lugs (included with switch) Horizontally positioned Vertically positioned Quick fixing/release bracket XCR Z Ø: elongated hole Ø x. Characteristics: pages / and / / References: page / Operation: page /

8 Dimensions (continued) Osiswitch Classic For conveyor belt shift monitoring applications, type XCR T XCR T, T 0 () () () XCR T 0 () 0 () () () 0 0 () 00 max., min. () 0 max. () 0 max. () plain entry for n cable gland. () tapped entry for n cable gland. Supplementary fixing using adjustable lugs (included with XCR T and T) Horizontally positioned Vertically positioned Ø: elongated hole Ø x Quick fixing/release bracket XCR Z Characteristics: pages / and / References: page / Operation: page / /

9 References, characteristics, setting-up Osiswitch Classic For hoisting and mechanical handling applications, type XCK MR Complete switches with cable entries Type of operating head Angular Type of operator With cruciform metal rods With cruciform metal rods, reversed head References for complete switches ( N/C contact with positive opening operation on contacts ) Devices with tapped cable entries ISO M0 x. A B x -pole N/C + N/C break before make contacts (non interchangeable contacts) XCK MRDH XCK MRDH Devices with cable entries for cable gland x -pole N/C + N/C break before make contacts (non interchangeable contacts) A B XCK MRD XCK MRD Weight () Complementary characteristics not shown under general characteristics (page /) Switch actuation Lateral Maximum actuation speed. m/s Mechanical durability million operating cycles Minimum torque For tripping 0. N.m For positive opening 0. N.m Accuracy ± 0. Cable entry tapped entries ISO M0 x., clamping capacity to tapped entries for cable gland conforming to NF C -00 (DIN Pg.), clamping capacity to Setting-up Stop A A B B Slowing down A B B 0 B 0 A 0 A A B Slowing down A A B B Stop A 0 0 B A B A B Direction of rotation Direction of rotation Reference mark on head () Direction of rotation Direction of rotation A A B B B A B 0 B 0 A 0 A A B A A B B 0 0 A B A B 0 Contact A Contact B Contact A Contact B Contact A Contact B Contact A Contact B Contact A Contact B () Triangle symbol marked on top of operating head /0

10 References (continued), dimensions Osiswitch Classic For hoisting and mechanical handling applications, type XCK MR Complete switches with cable entries References for separate parts Description Reference Weight Rod U, L 00 XCR Z XCR Z0 Dimensions XCK MRDH XCK MRD XCK MRDH XCK MRD 00,,,,, () () 0 (), (), 00 () XCK MRDpH tapped entries ISO M0 x.. XCK MRDp tapped entries for n cable gland. () centring holes Ø. ± 0., for cover fixing screws alignment. Ø : elongated holes. x., inclined at 0 for M screws. 0 /

11 Presentation For materials handling applications, type XC AC b XC AC with slow break contacts v With head for linear movement (plunger) 00_ 00_ 000_ Page / 00_ 00_ Page / 0 /

12 General characteristics For materials handling applications, type XC AC Environment characteristics Conformity to standards IEC/EN 0--, IEC 0-, VDE 00-00, CSA C- n Product certifications Special version CSA 00 V (ac) HD Protective treatment Version Standard TC, special TH Ambient air temperature For operation C For storage C Operating position All positions Vibration resistance gn (0 00 Hz) conforming to IEC 00-- Shock resistance gn ( ms) conforming to IEC 00-- Electric shock protection Class I conforming to IEC 0 and NF C 0-00 Degree of protection IP conforming to IEC 0 and NF C 0-00 Mechanical durability 0 million operating cycles Cable entry tapped entries for n cable gland Contact block characteristics Conventional thermal current 0 A Rated insulation voltage Slow break contact blocks a 00 V and c 00 V conforming to IEC 0--, NF C 0-00 a and c 00 V conforming to CSA C- n Resistance across terminals mω Minimum tripping force XC ACp: N, XC ACp: N, XC ACp: N Terminal referencing Conforming to CENELEC EN 00 Short-circuit protection 0 A cartridge fuse type gg (gl) Electrical durability b Conforming to IEC 0-- Appendix C b Utilisation categories AC- and DC- b Maximum operating rate: 00 operating cycles/hour b Load factor: 0. Slow break contact blocks a.c. supply a 0/0 Hz inductive circuit d.c. supply c inductive circuit Power broken in VA Voltage V 0 0 For million operating cycles For million operating cycles Power broken in W Voltage V 0 0 For million operating cycles For million operating cycles 0 0 /

13 References, characteristics For materials handling applications, type XC AC Complete switches with slow break contacts Type of head Plunger Type of operator End plunger End ball bearing plunger References of complete switches Single pole C/O slow break ZC AZ -pole N/C + N/O break before make, slow break ZC AZ -pole N/O + N/C make before break, slow break ZC AZ -pole N/C + N/C simultaneous, slow break ZC AZ -pole N/O + N/O simultaneous, slow break ZC AZ -pole N/C + N/C staggered, slow break ZC AZ -pole N/O + N/O staggered, slow break ZC AZ Roller lever Offset roller lever Reinforced roller lever Roller lever on needle roller bearing XC AC XC AC XC AC XC AC XC AC XC AC,,,, XC AC XC AC XC AC XC AC XC AC XC AC,, XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC - XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC XC AC -,,,,,,,,, - -, Weight () Contact operation contact closed contact open Complementary characteristics not shown under general characteristics (page /) Switch actuation On end By 0 cam Type of actuation,,,,,,,,,, - - A,,,, 0,,,,,,,, - - B,,,, 0,,,,,,,, - -,,,,,,,,,,,,, - -,,,,,,,,,,,,, Maximum actuation speed 0. m/s m/s (direction A), 0. m/s (direction B) () Cable entry tapped entries for n (DIN Pg.) cable gland, clamping capacity to ( entries fitted with blanking plug) Connection Screw terminals. Clamping capacity: min x 0., max x. () For a cam the maximum actuation speed becomes 0. m/s and for a cam, m/s. 0 /

14 Dimensions For materials handling applications, type XC AC Complete switches with slow break contacts XC ACp XC ACp XC ACp () () () XC ACp XC ACp, XC ACp 0 0 0, Ø,, () () () tapped entries for n cable gland or ISO 0 with adaptor DE RA0. Ø: elongated holes Ø. x 0. 0 /

15 References For materials handling applications, type XC AC Replacement parts ZC AC00 Plunger heads Type of operator Maximum actuation speed Type of actuation Reference Weight For actuation on end End plunger 0. m/s ZC AC For actuation by 0 cam End ball bearing plunger 0. m/s ZC AC ZC AC00 Roller lever m/s (direction A) 0. m/s (direction B) A ZC AC B 0 ZC AC00 ZC AC00 ZC AC00 ZC AC00 ZC AZp Reinforced roller lever Offset roller lever Roller lever on needle roller bearing m/s (direction A) 0. m/s (direction B) m/s (direction A) 0. m/s (direction B) m/s (direction A) 0. m/s (direction B) ZC AC00 0. B ZC AC B ZC AC00.0 B Contact blocks Type of contact Scheme Reference Weight C/O, single pole ZC AZ 0.00 N/C + N/O break before make ZC AZ 0.0 N/O + N/C make before break ZC AZ 0.00 N/C + N/C simultaneous ZC AZ 0.0 N/O + N/O simultaneous ZC AZ 0.0 N/C + N/C staggered ZC AZ 0.00 N/O + N/O staggered ZC AZ 0.00 Adaptation plate Description Reference Weight Mounting plate (For replacing an old version type RN- limit switch by an XC-AC limit switch) A A A ZC AZ.0 /

16 Dimensions For materials handling applications, type XC AC Replacement parts Dimensions ZC AC00 ZC AC00 ZC-AC ZC AC00 ZC AC00, AC , Ø, 0 /

17 Presentation Osiswitch Application For very severe applications, type XC J b XC J with cable entry v With head for linear movement (plunger) 00_ 00_ 00_ Page /0 v With head for rotary movement (lever) 00_ 00_ 00_ Page /0 0 /

18 General characteristics Osiswitch Application For very severe applications, type XC J Environment characteristics Conformity to standards Products IEC/EN 0--, IEC 0-, VDE 00-00, UL 0, CSA C- n Machine assemblies IEC/EN 00-, NF C -0 Product certifications Standard version DEMKO, NEMKO, CSA 00 V c HD, a 0 W Special version UL 0 V a HD Listed, CSA 00 V a HD, 0 W with / NPT tapped cable entry Protective treatment Standard version TC Ambient air temperature For operation C. Special adaptable sub-assemblies: - 0 C or + 0 C For storage C Vibration resistance 0 gn (0 00 Hz) conforming to IEC 00-- Shock resistance gn ( ms) conforming to IEC 00-- Electric shock protection Class I conforming to IEC 0 and NF C 0-00 Degree of protection IP conforming to IEC 0, IP conforming to NF C 0-00 Repeat accuracy 0.0 on the tripping points, with million operating cycles for head with end plunger Cable entry entry incorporating cable gland. Clamping capacity:. Contact block characteristics Rated operational characteristics a AC-; A00 (Ue 0 V, Ie A) c DC-; Q00 (Ue 0 V, Ie 0. A), conforming to IEC 0-- Appendix A, EN 0-- Rated insulation voltage 00 V conforming to IEC 0--, group C conforming to NF C 0-00, 00 V conforming to CSA C- n Resistance across terminals mω conforming to NF C -00 method A or IEC 0- category Short-circuit protection 0 A cartridge fuse type gg (gl) Connection Screw clamp terminals XCK Z0: clamping capacity, min: x 0., max: x. XES P0p: clamping capacity, min: x 0., max: x. Minimum actuation speed m/minute Electrical durability b Conforming to IEC 0-- Appendix C b Utilisation categories AC- and DC- b Maximum operating rate: 00 operating cycles/hour b Load factor: 0. XCK Z0, XES P0, XES P0 a.c. supply a 0/0 Hz inductive circuit Ithe / V Millions of operating cycles 0, 0 V V 0, 0 V 0, 0 Current in A d.c. supply c Voltage V 0 Power broken in W for million operating cycles 0 W 0 /

19 References, characteristics Osiswitch Application For very severe applications, type XC J Complete switches, fixed body, cable entry incorporating cable gland Type of head Plunger Rotary Type of operator References Single pole C/O XCK Z0 Metal end plunger Steel roller plunger () Adjustable throughout 0. ZC JC + ZC JE, 0 0, ZC JC + ZC JE, (A) 0 0, Metal side plunger ZC JC + ZC JE, 0 0, Thermoplastic roller lever () Variable length thermoplastic roller lever () Actuation from left AND right ZC JC + ZC JE0 + ZC JY ZC JC + ZC JE0 + ZC JY Actuation from left OR right ZC JC + ZC JE0 + ZC JY ZC JC + ZC JE0 + ZC JY Steel rod lever U () ZC JC + ZC JE0 + ZC JY ZC JC + ZC JE0 + ZC JY Weight () Contact operation contact closed (A) cam displacement contact open Complementary characteristics not shown under general characteristics (page /) Switch actuation On end By 0 cam On end By 0 cam By any moving part Type of actuation Maximum actuation speed 0. m/s. m/s Mechanical durability (in millions of operating cycles) 0 0 Minimum tripping force or torque N N With head ZC JE0: 0.0 N.m With head ZC JE0: 0.0 N.m Cable entry tapped entry incorporating metal cable gland. Clamping capacity to. Other versions Switches with gold flashed contacts. Special protective treatments. Please consult your Regional Sales Office. 0 /0

20 Dimensions Osiswitch Application For very severe applications, type XC J Complete switches, fixed body, cable entry incorporating cable gland ZC JC + ZC JE ZC JC + ZC JE ZC JC + ZC JE,,, () 0 () 0 () 0 0 ZC JC + ZC JE0p + ZC JY ZC JC + ZC JE0p + ZC JY ZC JC + ZC JE0p + ZC JY () 0... () () () 0 () () () Fixing from the rear: by M screws. Depth of thread on switch: 0. () max. () max. () max. Ø: Fixing from the front via holes Ø.. Cable gland incorporated (all XC JC models). 0 /

21 Presentation Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Variable composition ZC JY ZC JE ZC JE0 ZC JY ZC JE ZC JE ZC JY ZC JY ZC JE ZC JE ZC JE ZC JE0,JE0, JE0,JE0 ZC JY ZC JY ZC JE ZC JE0 ZC JY ZC JY ZC JE ZC JE ZC JY ZC JE0,JE0, JE0 ZC JE ZC JE ZC JC, JC ZC JD ZC JC, JC, JC, JC ZC JD, JD 0 Plunger head Rotary head Multi-directional head /

22 References Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Adaptable sub-assemblies Bodies with contacts for plunger or rotary head Type With contact block Scheme Reference Weight Fixed bodies step Single-pole C/O (XCK Z0) ZC JC 0. ZC JCp Double-pole C/O simultaneous (XES P0) ZC JC 0. step Double-pole C/O staggered (XES P0) Plug-in bodies step Single-pole C/O ZC JC 0. ZC JD 0.0 Double-pole C/O simultaneous ZC JD 0.0 ZC JDp step Double-pole C/O staggered ZC JD 0.0 Bodies incorporating gold flashed contacts, for plunger or rotary head Type With contact block Scheme Reference Weight Fixed bodies step Single-pole C/O (XCK Z0) ZC JC 0. ZC JCp Double-pole C/O simultaneous (XES P0) step Double-pole C/O staggered (XES P0) ZC JC 0.0 ZC JC Operation: page / Dimensions: pages / and / /

23 References (continued) Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Adaptable sub-assemblies ZC JEp Plunger heads Type of operator For actuation on end End plunger metal Compatible bodies ZC Jp ZC Jp Maximum actuation speed Reference Weight 0. m/s ZC JE 0. ZC Jp 0. m/s ZC JE 0. ZC JEp Side plunger metal ZC Jp ZC Jp 0. m/s ZC JE 0.0 ZC Jp 0. m/s ZC JE 0.0 ZC JE For actuation by 0 cam End ball bearing plunger ZC Jp ZC Jp 0. m/s ZC JE 0.0 End roller plunger steel ZC Jp ZC Jp m/s ZC JE 0.00 ZC JEp ZC Jp m/s ZC JE 0.00 Side plunger with horizontal roller steel ZC Jp ZC Jp 0. m/s ZC JE 0. ZC JEp ZC Jp 0. m/s ZC JE 0. Side plunger with vertical roller steel ZC Jp ZC Jp 0. m/s ZC JE 0. ZC Jp 0. m/s ZC JE 0. ZC JEp 0 Operation: page / Dimensions: pages / and / /

24 References (continued) Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Adaptable sub-assemblies Rotary heads (without operating lever) ZC JE0p Type Spring return Actuation from left AND right Compatible bodies ZC Jp ZC Jp Maximum actuation speed Reference Weight. m/s ZC JE0 0.0 ZC Jp. m/s ZC JE0 0.0 Actuation from right ZC Jp ZC Jp. m/s ZC JE0 0.0 ZC Jp. m/s ZC JE0 0.0 Actuation from left ZC Jp ZC Jp. m/s ZC JE0 0.0 ZC Jp. m/s ZC JE0 0.0 Actuation from left OR right (see page /) ZC Jp ZC Jp. m/s ZC JE0 0.0 Stay put (see page /) Actuation from left AND right ZC Jp ZC Jp. m/s ZC JE0 0.0 Multi-directional head (with operator) Type of operator For actuation by any moving part Cat s whisker Compatible bodies ZC Jp ZC Jp Maximum actuation speed Reference Weight m/s in any direction ZC JE0 0.0 ZC JE0 0 Operation: page / Dimensions: pages / and / /

25 References (continued) Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Adaptable sub-assemblies ZC JYp Operating levers for rotary heads Description Reference Weight For actuation by 0 cam Roller lever () Thermoplastic ZC JY 0.00 ZC JY Steel ZC JY 0.00 Steel, ball bearing mounted ZC JY 0.00 ZC JY Variable length roller lever () Thermoplastic ZC JY 0.0 For actuation by any moving part Rigid rod lever Steel U, L () ZC JY 0.0 Spring lever () ZC JY 0.00 ZC JY ZC JY Spring-rod lever () ZC JY 0.00 ZC JY For actuation by specific cam (only for operation with head ZC JE0, see page /) Forked arm with rollers thermoplastic () track ZC JY 0.0 track ZC JY 0.0 ZC JY () Adjustable throughout 0. Other versions Other operating levers for rotary heads. Please consult your Regional Sales Office. 0 Operation: page / Dimensions: pages / and / /

26 References (continued) Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Adaptable sub-assemblies XCK Z0 Contact blocks Type of contact Scheme For body Reference Weight Single-pole C/O ZC JC XCK Z Double-pole C/O simultaneous ZC JC XES P0 0.0 XES P0p Double-pole C/O staggered ZC JC XES P0 0.0 Contact blocks with gold flashed contacts Type of contact Scheme For body Reference Weight Single-pole C/O ZC JC XCK Z Double-pole C/O simultaneous ZC JC XES P0 0.0 Double-pole C/O staggered ZC JC XES P Operation: page / Dimensions: pages / and / /

27 Operation, dimensions Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Adaptable sub-assemblies Operation (function diagrams) Heads ZC JE, JE with body Head ZC JE with body Head ZC JE with body ZC Jp ZC Jp ZC Jp ZC Jp ZC Jp ZC Jp, 0 0,, / /- / /- 0 0,, (A) 0 0, Heads ZC JE, JE with body Heads ZC JE0, JE0, JE0, JE0 with body ZC Jp ZC Jp ZC Jp ZC Jp / /- / /- Head ZC JE0 with body Head ZC JE0 with body ZC Jp ZC Jp ZC Jp ZC Jp, (A) 0 0, Contact operation G contact closed H contact open (A) cam displacement Heads ZC JE, JE with body ZC Jp Unactuated st step nd step / /- / /- / /- / /- 0,(A) 0, , 0,(A) 0, / /- / /- 0 / /- / /- 0 0, 0 0,, / /- / /- 0, 0, Heads ZC JE, JE, J with body ZC Jp Unactuated st step nd step,, Heads ZC JE0 with body ZC Jp Unactuated Actuated from left Actuated from right Heads ZC JE0, JE0 with body ZC Jp Unactuated st step nd step Dimensions Fixed bodies ZC JC, JC, JC () 0 Plug-in bodies ZC JD, JD, JD 0 0 (),, 0 () Incorporated cable gland () Fixing from the rear by M screws, depth of thread on switch: 0 Ø: fixing from the front via holes Ø. (), () Incorporated cable gland Ø: fixing from the rear by M screws Fixing from the front via holes Ø. (remove front part of switch for access), References: pages / to / /

28 Dimensions (continued) Osiswitch Application For very severe applications, type XC J Fixed or plug-in body Adaptable sub-assemblies Plunger heads ZC JE, JE ZC JE ZC JE, JE,,, ZC JE, JE ( position) ZC JE, JE, JE, JE ( position),, Rotary heads (ZC JE0 to JE0) with operating lever ZC JY, JY, JY ZC JY ZC JY () () ZC JY ZC JY () max. () max Rotary heads (ZC-JE0) with operating lever Multi-directional heads ZC JY ZC JY ZC JE0 0 0, References: pages / to / Operation: page / /

29 References Osiswitch Application For very severe applications, type XC J Fixed or plug-in body. Adaptable sub-assemblies for low temperature applications (- 0 C) Bodies with contacts for plunger or rotary head Type With contact block Scheme Reference Weight Fixed bodies step Single-pole C/O (XCK Z0) ZC JC 0. ZC JCp Double-pole C/O simultaneous (XES P0) ZC JC 0. step Double-pole C/O staggered (XES P0) ZC JC 0. Plug-in bodies step Single-pole C/O ZC JD 0.0 ZC JDp Double-pole C/O simultaneous step Double-pole C/O staggered ZC JD 0.0 ZC JD 0.0 Plunger heads Type of operator For actuation on end End plunger metal Side plunger metal Compatible bodies Maximum actuation speed Reference Weight ZC Jp 0. m/s ZC JE 0. ZC Jp ZC Jp 0. m/s ZC JE 0. ZC Jp 0. m/s ZC JE 0.0 ZC Jp ZC Jp 0. m/s ZC JE 0.0 For actuation by 0 cam End ball bearing plunger End roller plunger steel ZC Jp ZC Jp 0. m/s ZC JE 0.0 ZC Jp m/s ZC JE 0.00 ZC Jp ZC Jp m/s ZC JE 0.00 ZC JEp Side plunger with horizontal roller steel Side plunger with vertical roller steel ZC Jp 0. m/s ZC JE 0. ZC Jp ZC Jp 0. m/s ZC JE 0. ZC Jp 0. m/s ZC JE 0. ZC Jp ZC Jp 0. m/s ZC JE 0. 0 Setting-up: page / Dimensions: pages / and / /0

30 References (continued) Osiswitch Application For very severe applications, type XC J Fixed or plug-in body. Adaptable sub-assemblies for low temperature applications (- 0 C) Rotary heads (without operating lever) ZC JE0p Type Spring return Actuation from left AND right Compatible bodies ZC Jp ZC Jp Maximum actuation speed Reference Weight. m/s ZC JE0 0.0 ZC Jp. m/s ZC JE0 0.0 Actuation from right ZC Jp ZC Jp. m/s ZC JE0 0.0 ZC Jp. m/s ZC JE0 0.0 Actuation from left ZC Jp ZC Jp. m/s ZC JE0 0.0 ZC Jp. m/s ZC JE0 0.0 Actuation from left OR right (see page /) Stay put (see page /) Actuation from left AND right ZC Jp ZC Jp ZC Jp ZC Jp. m/s ZC JE m/s ZC JE0 0.0 Multi-directional head (with operator) Type of operator For actuation by any moving part Cat s whisker Compatible bodies ZC Jp ZC Jp Maximum actuation speed Reference Weight m/s in any direction ZC JE0 0.0 ZC JE0 0 Setting-up: page / Dimensions: pages / and / /

31 References (continued) Osiswitch Application For very severe applications, type XC J Fixed or plug-in body. Adaptable sub-assemblies for low temperature applications (- 0 C) Operating levers for rotary heads Description Reference Weight For actuation by 0 cam Roller lever () Thermoplastic ZC JY 0.00 ZC JYp ZC JY Steel ZC JY 0.00 Steel, ball bearing mounted ZC JY 0.00 Variable length roller lever () Thermoplastic ZC JY 0.0 ZC JY For actuation by any moving part Rigid rod lever Steel U, L () ZC JY 0.0 Spring lever () ZC JY 0.00 ZC JY ZC JY Spring-rod lever () ZC JY 0.00 For actuation by specific cam (only for operation with head ZC JE0, see page /) ZC JY Forked arm with rollers thermoplastic () track ZC JY 0.0 track ZC JY 0.0 Contact blocks Type of contact Scheme For body Reference Weight ZC JY Single-pole C/O ZC JC XCK Z Double-pole C/O simultaneous ZC JC XES P0 0.0 XCK Z0 Double-pole C/O staggered () Adjustable throughout 0. ZC JC XES P0 0.0 XES P0p Other versions Other operating levers for rotary heads. Please consult your Regional Sales Office. 0 Setting-up: page / Dimensions: pages / and / /

32 References (continued) Osiswitch Application For very severe applications, type XC J Fixed body. Adaptable sub-assemblies for high temperature applications (+ 0 C) Bodies with contacts for plunger or rotary head Type With contact block Scheme Reference Weight Fixed bodies step Single-pole C/O (XCK Z0) ZC JC 0. ZC JCp Double-pole C/O simultaneous (XES P0) ZC JC 0. ZC JEp ZC JEp step Double-pole C/O staggered (XES P0) Plunger heads Type of operator For actuation on end End plunger metal Compatible bodies ZC JC ZC JC Maximum actuation speed ZC JC 0. Reference Weight 0. m/s ZC JE 0. ZC JC 0. m/s ZC JE 0. Side plunger metal ZC JC ZC JC 0. m/s ZC JE 0.0 ZC JC 0. m/s ZC JE 0.0 ZC JE For actuation by 0 cam End ball bearing plunger ZC JC ZC JC 0. m/s ZC JE 0.0 ZC JEp End roller plunger steel ZC JC ZC JC m/s ZC JE 0.00 ZC JC m/s ZC JE 0.00 ZC JEp Side plunger with horizontal roller steel ZC JC ZC JC 0. m/s ZC JE 0. ZC JC 0. m/s ZC JE 0. Side plunger with vertical roller steel ZC JC ZC JC 0. m/s ZC JE 0. ZC JEp ZC JC 0. m/s ZC JE 0. 0 Setting-up: page / Dimensions: pages / and / /

33 References (continued) Osiswitch Application For very severe applications, type XC J Fixed body. Adaptable sub-assemblies for high temperature applications (+ 0 C) Rotary heads (without operating lever) ZC JE0p Type Spring return Actuation from left AND right Compatible bodies ZC JC ZC JC Maximum actuation speed Reference Weight. m/s ZC JE0 0.0 ZC JC. m/s ZC JE0 0.0 Actuation from right ZC JC ZC JC. m/s ZC JE0 0.0 ZC JC. m/s ZC JE0 0.0 Actuation from left ZC JC ZC JC. m/s ZC JE0 0.0 ZC JC. m/s ZC JE0 0.0 Stay put (see page /) Actuation from left AND right ZC JC ZC JC. m/s ZC JE0 0.0 ZC JE0 Multi-directional head (with operator) Type of operator For actuation by any moving part Cat s whisker Compatible bodies ZC JC ZC JC Maximum actuation speed Reference Weight m/s in any direction ZC JE Setting-up: page / Dimensions: pages / and / /

34 References (continued) Osiswitch Application For very severe applications, type XC J Fixed body. Adaptable sub-assemblies for high temperature applications (+ 0 C) Operating levers for rotary heads Description Reference Weight For actuation by 0 cam Roller lever () Thermoplastic ZC JY 0.00 ZC JYp Steel ZC JY 0.00 Steel, ball bearing mounted ZC JY 0.00 Offset roller lever () Thermoplastic ZC JY 0.0 ZC JY Variable length roller lever () Thermoplastic ZC JY 0.0 Variable length offset roller lever () Thermoplastic ZC JY 0.00 For actuation by any moving part Rigid rod lever Steel U, L () ZC JY 0.0 Spring lever () ZC JY 0.00 ZC JY ZC JY Spring-rod lever () ZC JY 0.00 For actuation by specific cam (only for operation with head ZC JE0, see page /) ZC JY Forked arm with rollers thermoplastic () track ZC JY 0.0 track ZC JY 0.0 ZC JY Contact blocks Type of contact Scheme For body Reference Weight Single-pole C/O ZC JC XCK Z XCK Z0 Double-pole C/O simultaneous ZC JC XES P0 0.0 Double-pole C/O staggered () Adjustable throughout 0. ZC JC XES P0 0.0 XES P0p Other versions Other operating levers for rotary heads. Please consult your Regional Sales Office. 0 Setting-up: page / Dimensions: pages / and / /

35 References, dimensions Miniature snap switches Osiswitch Subminiature design, DIN B format, sealed Sub-subminiature design, DIN D format References Subminiature design, DIN B format, sealed Type of operator Plunger Flat lever () Roller lever () Single-pole C/O. cable clip tag connections XEP EW () XEP EWA () XEP EWA () Wiring: Weight (g)... Black Grey Pre-cabled XEP EFD () XEP EFDA () XEP EFDA () Blue connections Weight (g)... Separate components Flat lever () ZEP L () Weight (g) 0. Roller lever () ZEP L () Weight (g) 0. Sub-subminiature design, DIN D format Type of operator Plunger Flat lever () Single-pole C/O Solder tag XEP PW () XEP PWZB () connections Weight (g).. Dimensions XEP EW XEP EWA XEP EWA 0,,,, r Ø, A(), B(), r F, r 0,,,, Ø,,,, 0,, x0, XEP EFD XEP EFDA XEP EFDA A() B(), r F, r 0,,, XEP PW 0, 0,, 0,,,,,,, XEP PWZB 0,,, Z() r, F 0,x,, 0,,,,,,,,, () In order to avoid damage to the fixing spigots, removal of the lever from complete products is not recoended. () Levers only for mounting on basic (plunger) snap switches (XEP EW and XEP EFD). () Switches sold in lots of. () A, B, Z: lever fixing positions. /

36 Characteristics Miniature snap switches Osiswitch Subminiature design, DIN B format, sealed Sub-subminiature design, DIN D format Switch type XEP Epp, XEP PW XEP EppA, XEP PWZB XEP EppA Plunger Flat lever Roller lever Environment characteristics Lever fixing position () A A Switch actuation On end Horizontal Product certifications e, IEC 0--, EN 0--, c UR us, UL 0, EN 0 Degree of protection IP XEP EFDpp, case IP and tags IP 00 XEP EWpp, case IP 0 and tags IP 00 XEP PWpp Operating temperature C XEP EFDpp, C XEP EWpppp and XEP Pppp Materials Enclosure Polyester XEP, diallyl-phtalate XEP Lever Stainless steel Stainless steel, glass reinforced polyamide roller Contact AgCdO XEP Epp, Ag XEP Tags Tinned brass XEP EWppp, gold plated brass XEP Ppp Mechanical characteristics Lever fixing position () Maximum tripping force XEP A. N 0. N 0. N B. N. N. N XEP N 0.0 N Minimum release force XEP A 0.0 N 0.0 N 0. N B 0.0 N 0.0 N 0. N XEP 0.0 N 0. N Maximum permissible end of travel force XEP A 0 N. N. N B 0 N N. N XEP 0 N Tripping point (TP) () XEP A.0 +/ /-.. +/-. B.0 +/ /-.0. +/- 0. XEP.0.0 Maximum differential travel XEP A B XEP Minimum overtravel XEP A B XEP 0.0 Inter-contact distance XEP 0. XEP 0. Mechanical durability XEP million operating cycles XEP 0. million operating cycles Electrical characteristics Operational characteristics XEP AC-: B00 (Ue: 0 V, Ie:. A) DC-: R00 (Ue: 0 V, Ie: 0. A) conforming to IEC 0--, EN 0-- Appendix A -0 V AC.0 A conforming to UL 0 () A 0 V AC 0,000 cycles conforming to EN 0 XEP AC-: D00 (Ue: 0 V, Ie: 0. A) conforming to IEC 0--, EN 0-- Appendix A Thermal current XEP. A on 0 V (0/0 Hz) XEP. A on 0 V (0/0 Hz) Connection XEP XEP EWp:. cable clip tags XEP EFD: Pre-cabled (horizontally in-line), x 0., length 0. m XEP Solder tags Operating curves XEP Epp XEP Ppp Number of cycles x ,0 0, 0, 0, 0 A Current 0 V a: resistive circuit Number of cycles V a Resistive circuit Inductive circuit 0, 0, 0, 0 A Cos ϕ 0. Current 0 () Miniature snap switches fitted with a lever are supplied with the lever fixed in position A (see page /). For basic (plunger) snap switches, it is possible to fix a lever in position A or B, depending on the required tripping conditions (see page /). () Position of the operator in relation to the switch fixings (fixing hole centre line), at the instant the contact changes state. /

37 References, dimensions 0 Miniature snap switches Osiswitch Miniature design, DIN A format References Type of operator Plunger Flat lever () Roller lever () Singlepole C/O snap action Standard contacts Solder tags XEP SW () XEP SWB () XEP SWB (). cable clip tags XEP SW () XEP SWB () XEP SWB (). cable clip tags XEP SW () XEP SWB () XEP SWB () Weight (g)... Very low Solder tags XEP SW () XEP SWB () XEP SWB () operating. cable clip tags XEP SW () XEP SWB () XEP SWB () force. cable clip tags XEP SW () XEP SWB () XEP SWB () contacts Weight (g)... Separate components Flat lever () ZEP L () Weight (g) 0. Roller lever () ZEP L () Weight (g) Dimensions XEP SpW XEP SpW XEP SpW 0, 0,,,,, ZEP L,, 0, A B C, r,,,,,,,,,,,,,x0, 0,,,, 0, 0, ZEP L () In order to avoid damage to the fixing spigots, removal of the lever from complete products is not recoended. () Switches sold in lots of 0. () Levers only for mounting on basic (plunger) snap switches (XEP SpW, XEP SpW and XEP SpW), in fixing positions A, B or C. 0,,,, A B C,,,,,,, r, 0,,,,x0, 0, 0,,,,, 0, A B C,,,,,,,,,,,x0, 0 /

38 Characteristics 0 Miniature snap switches Osiswitch Miniature design, DIN A format Switch type Type of operator XEP SpW XEP SpWB XEP SpWB Plunger Flat lever Roller lever Environment characteristics Lever fixing position () B B Switch actuation On end Horizontal Product certifications c UR us, e, IEC/EN 0--, UL 0, EN 0- Degree of protection Case IP 0 and tags IP 00 Operating temperature C Materials Enclosure Polyester Lever Stainless steel Stainless steel, glass reinforced polyamide roller Contact AgNi Mechanical characteristics Lever fixing position () Maximum tripping force Standard A 0. N 0. N B 0. N 0. N C 0. N 0.N Very low force A 0. N 0.0 N B 0. N 0. N C 0. N 0. N Minimum release force Standard A 0.0 N 0.0 N B 0.0 N 0.0 N C 0.0 N 0. N Very low force A 0.0 N 0.0N B 0.0 N 0.0 N C 0.0 N 0.0 N Maximum permissible end of travel force Tripping point (TP) () Maximum differential travel Standard, very low force Standard, very low force Standard, very low force A 0 N N B 0 N 0 N C 0 N N A.0 +/ / /-. B.0 +/ / /-. C.0 +/ / /-. A 0..0 B C Minimum overtravel Standard A.0.0 B.0.0 C.0.0 Very low force A.0.0 B.0.0 C.0. Inter-contact distance 0.0 Mechanical durability for / Standard 0 million operating cycles overtravel Very low force 0 million operating cycles Electrical characteristics Operational characteristics Standard AC-: B00 (Ue: 0 V, Ie:. A) DC-: R00 (Ue: 0 V, Ie: 0. A) conforming to IEC/EN 0-- Appendix A -0 VAC 0.A - / HP conforming to UL 0 () A 0 V AC 0,000 cycles conforming to EN 0- Very low force AC-: D00 (Ue: 0 V, Ie: 0. A) conforming to IEC/EN 0-- Appendix A -0 V AC A - /0 HP conforming to UL 0 () A 0 V AC 0,000 cycles conforming to EN 0- Thermal current Standard A on 0 V (0/0 Hz) Very low force A on 0 V (0/0 Hz) Connection XEP SpW: solder tags, XEP SpW:. cable clip tags XEP SpW:. cable clip tags. Operating curves XEP Spp Number of cycles V Resistive circuit Inductive circuit Cos ϕ 0. XEP Spp Current Current 0, 0, 0, A 0, 0, 0, A () Miniature snap switches fitted with a lever are supplied with the lever fixed in position B (see page /). For basic (plunger) snap switches, it is possible to fix a lever in position A, B or C, depending on the required tripping conditions (see page /). () Position of the operator in relation to the switch fixings (fixing hole centre line), at the instant the contact changes state. Number of cycles V Resistive circuit Inductive circuit Cos ϕ 0. 0 /

39 References, dimensions Miniature snap switches Osiswitch Sealed design Pre-cabled Type of head Plunger (fixing by the body) Type of operator Head with flat plunger Head with domed encased plunger References Single-pole C/O Wiring: Black Brown Blue XC 00L XC 0L Weight () Dimensions XC 00L, PA 0, XC 0L r, PA 0, /0

40 Characteristics Miniature snap switches Osiswitch Sealed design Pre-cabled Switch type XC 00p XC 0p Environment characteristics Switch actuation On end, flat plunger () On end, domed plunger () Product certifications e, IEC 0-- Degree of protection IP Operating temperature C Materials Internal housing Metal Casing Nitrile Fixing support Steel, zinc passivated Contact Ag Mechanical characteristics Maximum tripping force Minimum release force. N. N Maximum permissible end of travel force 0 N Tripping point (TP) (). ± 0.. ± 0. Maximum differential travel Minimum overtravel Inter-contact distance Mechanical durability Electrical characteristics Operational current Thermal current/insulation voltage million operating cycles A on V (0/0 Hz) A/0 V Connection Electrical durability A0 VVF cable, x 0., length metres, overall diameter. AC-: 0. million operating cycles Operating curve () Manual actuation must be made by an intermediate insulated part, in order to meet basic safety requirements. One of the two fixing holes must also be used as an earth protection terminal. () Distance between the base of the switch and the top of the plunger at the instant the contact changes state (see dimensions, page /0). 0 /

41 Presentation, terminology, characteristics, mounting Miniature snap switches Osiswitch Miniature design General Presentation XEP XC0 Terminology XEP EWp XEP EFDp XEP Electromechanical detection b Osiswitch miniature snap switches, featuring electromechanical technology, assure the following functions: v detection of presence or absence, v detection of position. Actuation of the operator (plunger or lever) on the miniature snap switch causes the electrical contact to change state. This information can then be processed by a PLC controlling the installation. Osiswitch miniature snap switches can be used both for industrial applications and the building sector. Features b Osiswitch miniature snap switches incorporate a C/O, single break, contact. They are characterised by: v high electrical ratings for their very small size, v short tripping travel, v low tripping force, v high repeat accuracy on the tripping points, v long service life. Forces b Maximum tripping force: maximum force which must be applied to the operator to move it from the rest (unactuated) position to the trip position (tripping point). b Minimum release force: value to which the force on the operator must be reduced to allow the mechanism to return to its rest (unactuated) position. b Maximum permissible end of travel force: maximum force that can be applied to the operator at the end of its travel without damaging the switch. Position / Travel Tripping point: position of the operator in relation to the switch fixings (fixing hole centre line) at the instant the switch contact changes state. A Differential travel: distance between the tripping point and the position at which the snap action mechanism returns to its initial state on release of the operator. Overtravel limit: position of the operator when an extreme force has moved it to the effective end of its available travel. B Overtravel: distance between the tripping point and the overtravel limit. Mechanical characteristics NC NO T T The reference point for the figures given for forces and travel is a point F, which is situated on the plunger in the case of a basic switch or at from the end of the plain lever in the case of a lever operated switch. Changeover time b This is the time taken by the moving contact when moving from one fixed contact to another until it becomes fully stable (contact bounce included). b This time is related to the inter-contact distance, the mechanical characteristics of the snap action mechanism and the mass of the moving element. However, due to the mechanisms used, the time is largely independent to the speed of operation. It is normally less than 0 milliseconds (including bounce times of less than ms). T: bounce time Operating speed and maximum usable operating rate T: changeover time b Our miniature snap switches are suitable for a wide range of operating speeds: generally, from /mn to m/s. b The maximum usable operating rate on a light electrical load may be as high as 0 operations/second. A B C 0 Mounting A B C Mounting and operation b v v b To conform to the leakage paths and air gaps in standards EEC - EN/IEC 0 and EN/IEC 0: an insulation pad must be inserted between the snap switch and the fixing surface if the latter is metal, manual operation of a metal actuator must only be carried out with the aid of an intermediate actuator made of an insulating material. The installer must ensure adequate protection against direct contact with the output terminals. Actuation method b Direct operation: v the plunger should preferably be actuated along its axis. However, the majority of our miniature snap switches will accept skewed operation provided the angle of actuation is not more than. The travel of the actuator must not be limited to only reaching the tripping point. The actuator must always be operated in such a manner so that the plunger reaches a point at least 0. times the stated overtravel value of the switch. Steps must also be taken to ensure that it does not reach its end of travel nor exceed the maximum permissible end of travel force. /

42 Mounting, characteristics (continued) Miniature snap switches Osiswitch Miniature design General Mounting (continued) Actuation method (continued) b Lever operators: v when actuation is by a roller lever, force should preferably be applied in the direction shown in the diagrams opposite, v where the movements involved are fast, the ramp should be so designed as to ensure that the operator is not subjected to any violent impact or abrupt release. 0 0 A B C A B C Fixing - Tightening torque b The tightening torque of the fixing screws must conform to the following values: Ø of fixing screw.. Tightening torque (cm.n) Maximum Minimum Resistance to mechanical shock and vibration b Resistance to shock and vibration depends on the mass of the moving parts and on the forces holding the contacts together. b In general, for a miniature snap switch without accessory: v vibration > 0 gn, 0 to 00 Hz, v shock > 0 gn ms / sine wave. Electrical characteristics Number of cycles , 0, 0, 0 A Current Resistive circuit Inductive circuit Cos ϕ 0. Operating curves b These indicate the electrical life of the miniature snap switches under standard conditions (0 C, cycle/ seconds), by showing the number of switching operations which can be performed with given types of load. For sealed snap switches, the operating rate is cycle/ s. Insulation resistance b The insulation resistance of the miniature snap switches is generally greater than 0,000 MΩ, measured at 00 V d.c. 00 V Dielectric strength b The dielectric strength of our miniature snap switches is generally superior to: v 00 Volts between live parts and earth, v 000 Volts between contacts, v 00 Volts between contacts for switches with an inter-contact distance less than V 0 /

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

Safety dialogue solutions

Safety dialogue solutions General Presentation Emergency stop trip wire switches Emergency stop trip wire switches are designed to: b avert hazards (dangerous phenomena) at the earliest possible moment, or to reduce risks which

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards EN/IEC 6097-5-1 EN/IEC 600-, UL 508, CSA C- n EN/IEC 6097-5-5 and EN/ISO 850 for versions with trigger action Emergency stop Product certifications

More information

ZCK-E65 ZCK-Y51 ZCK-Y71 ZCK-Y61 ZCK-E09 (1) ZCK-E05 ZCK-J404H29

ZCK-E65 ZCK-Y51 ZCK-Y71 ZCK-Y61 ZCK-E09 (1) ZCK-E05 ZCK-J404H29 ZCK-E ZCK-E1 ZCK-Y ZCK-Y9 ZCK-E64 ZCK-E6 ZCK-Y1 ZCK-Y3 ZCK-E63 ZCK-Y91 ZCK-E6 ZCK-Y81 ZCK-E69 ZCK-Y71 ZCK-E67 ZCK-E9 (1) ZCK-Y61 ZCK-Y41 ZCK-Y43 ZCK-E6 ZCK-E8 ZCK-Y ZCK-Y ZCK-E619 ZCK-Y11 ZCK-E ZCK-E66

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C .1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A

3 - Cam switches. Contents 0. Complete switches, 10 A. Complete switches, 12 and 20 A. Adaptable sub-assemblies, 12 and 20 A Contents - Cam switches Selection guide............................................. page / Complete switches, A b Front mounting by Ø or Ø mm, with x mm front plate... page / v Switches and stepping switches..............................

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure. General-purpose Limit Switch CSM DS_E_3_ Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Elesta Elektrotechnik AG industry relays and accessories

Elesta Elektrotechnik AG industry relays and accessories Elesta Elektrotechnik AG industry relays and accessories edition 003 table of contents SKR-industry relay 4 SKR-screw socket with accessories 4 SFR-industry relay 6 SFR-screw socket with accessories 7

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

General 1-2-Opto-electronics Safety Switches 4-Emergency

General 1-2-Opto-electronics Safety Switches 4-Emergency General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

SQUARE D INDUSTRIAL CONTROL PRODUCTS

SQUARE D INDUSTRIAL CONTROL PRODUCTS SQUARE D INDUSTRIAL CONTROL PRODUCTS CLASS 9012 3a INDUSTRIAL PRESSURE SWITCHES Type A Heavy duty switch for virtually any industrial application involving air, water, steam or oil Bellows, piston and

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52

40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52 Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES 01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Technicaldata General

Technicaldata General Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

Pneumatic. PXC Limit Switches. Authorised Distributor TTS Valve Technologies Sdn Bhd

Pneumatic. PXC Limit Switches. Authorised Distributor TTS Valve Technologies Sdn Bhd Pneumatic PXC Limit Switches Limit Switches Series PXC High durability Very good repeat accuracy Design for process duty cycle Push-in or threaded connection Versatile and easily maintained Wide range

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

Pressure controls, type KP

Pressure controls, type KP Introduction KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. KP pressure

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Machine Safety Switches

Machine Safety Switches Machine Switches SI-LS31H Series 31 mm Limit-Switch-Style with Hinged Lever Actuators Features Limit switch design (EN 50047) For use on doors or flaps Positive opening safety contacts (IEC 60947-5-1)

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog 9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................

More information

D-Line Contactors, Overload Relays and Accessories

D-Line Contactors, Overload Relays and Accessories D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

FP2 Relay. The Best Relaytion

FP2 Relay. The Best Relaytion The Best Relaytion 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features Telecom / signal relay (dry

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information